STANDARD FEATURES
• NEW Factory authorized startup
• ENERGY STAR® Qualified
Gas
Genesis
DH5000 Single Source Gas
Hood-type Dishwashing Machine
• NEW Exclusive Built-in booster configured
for both 40° and 70° Rise
• Rinse Sentry – ensures 180°F final rinse
• Auto start – starts unit when hood is closed
• High efficiency 1 HP pump
• Up to 53 racks per hour
• Self draining pump
• Automatic tank fill
• Detergent/chemical connections
• Interchangeable upper and lower spray arm
• Automatic drain valve – drains wash tank when
power is off
• Vent fan control
• Bottom mounted digital controls
• PRV (Pressure Reducing Valve)
• Sloped hood keeps hot vapors away from operator
• Standard and Heavy Duty wash cycles
OPTIONS & ACCESSORIES
:: Drain Water Tempering Kit
:: Direct Vent Option with Fan
:: Racks
:: Peg
:: Flat
SPECIFIER STATEMENT
Specified unit will be Champion model Genesis, DH5000
single source gas hood-type dishwashing machine.
Features sloped hood, electronic controls, Rinse Sentry,
Auto start, interchangeable stainless steel wash and rinse
arms, up to 53 racks/hr., 0.83 US gals/rack.
1 year parts and labor warranty.
:: Door Interlock
:: Corner Operation Splash Baffle
::NEW Champion ION scale prevention system
Champion Industries, Inc.
3765 Champion Blvd., Winston-Salem, NC 27105
Tel: 336/661-1556 Fax: 336/661-1979
www.championindustries.com
(pdf) 12/15 Printed in U.S.A.
Champion, an Ali Group Company
GENESIS HOOD-TYPE
Project
Item No.
Quantity
25-5/8" 24-5/8"
GENESIS HOOD-TYPE
25-5/16"
34-1/8"
20-3/4"
8-1/4"
5-3/4"
GENESIS
3-1/4"
10"
DH5000 Single Source Gas
Hood-type Dishwashing Machine
Shipping weight crated: 300 lbs.
Dimensions shown in inches and [mm]
29-1/2"
6
Gas Booster
69-3/4"
60-1/8"
10-1/2"
31-3/8"
25-7/16"
19-5/8"
10-1/4"
8-1/2"
10-1/2"
7-1/8"
6"
3-1/2"
17"
Side View
Front View
19-5/8"
26-1/8"
27-1/2"
44-5/8"
41"
Gas Booster
25-5/8" 24-5/8"
Plan View
6-3/8"
34-1/8"
20-3/4"
8-1/4"
5-3/4"
Typical Table Construction
3-1/4"
10"
SPECIFICATIONS
Utilities
1 Electrical
Warning: Plumbing, electrical connections should
be made by qualified personnel who will observe all
the applicable plumbing, sanitary and safety codes
and the National Electrical Code.
Machine Connection (See Electrical Box)
Gas Booster Connection 15 AMPs
120V/60/1
2 Hot Water
3/4" NPT Hot Water 140°F for 40°F Rise
3/4" NPT Hot Water 110°F for 70°F Rise
20-22 PSI Flow pressure
6
17"
See Gas Flue Ventilation Note
4" Diameter Rear of Booster
6 Exhaust
250 CFM Hood Required
Motor horsepower
Water consumption
Gal. per hr. (max. use)
Gal. per rack 44
0.83
Minimum
Supply
Rated
Circuit"
7-1/8" Voltage
6
Amps Ampacity
"
3-1/2
208-240/60/1
15
20
19-5/8"
208-240/60/3
8
15
460-480/60/3
426-1/8" 15
150
180
Gas Heating
60-1/8"
Maximum
Overcurrent
Protective
Device
20
15
15
53
9.5
1 HP
Wash
Rinse
"
469-3/4
Natural
Gas
10-1/4"
5 Gas Flue Exhaust
8-1/2"
Racks per hr. (NSF rated)
Wash tank (gal.)
Temperature °F
2" OD Machine Drain Connection
3/4" NPT Relief Valve to Open Drain
Gas Booster
1/2" NPT Vent to Open Drain
10-1/2"
29-1/2"
3 Drain
40°F Rise Requires 58,000BTU/hr
70°F Rise Requires 105,000BTU/hr
PMG-60 Requires 1/2" NPT
31-3/8" Requires 3/4" NPT
PMG-100
25-7/16"
See Gas Piping
Note"
19-5/8
Capacities
PMG-60 (40°F rise)
PMG-100 (70°F rise)
58,000 BTU/hr
105,000 BTU/hr
Time cycle in seconds
Wash
Rinse
Sanitary Dwell
Total cycle
StandardExtended
3565
10
10
15
15
60
90