C55 Series Compact Cylinders

Compact Cylinder
New
ISO Standards [ISO/21287]
It is possible to mount small
auto switches on 4 surfaces.
Auto switches can be mounted on any of the 4
surfaces, depending on the installation conditions.
Improved flexibility of system design.
2-color indication solid state auto switch
Appropriate setting of the mounting position can be
performed without mistakes.
ON
Operating
range
OFF
Red
Green
Red
Proper operating range
The
green
light lights up at a proper operating range.
Even if 2-color indication solid state auto switches are fixed
at a proper operating range (the green light lights up), the
operation may become unstable depending on the
installation environment or magnetic field disturbance.
(Magnetic body, external magnetic field, proximal installation of
cylinders with built-in magnet and actuators, temperature change,
other factors for magnetic force fluctuation during operation, etc.)
NEW Bore sizes
ø80,ø100 added.
Series C55
CAT.ES20-184B
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
ISO Standards [ISO/21287]
Compact Cylinder
Series C55
ø20,ø25,ø32,ø40,ø50,ø63,ø80,ø100
How to Order
C55 B 20 10
With auto switch
CD55 B 20 10
M9B S
Number of auto switches
With auto switch
(Built-in magnet)
Nil
S
n
2 pcs.
1 pc.
“n” pcs.
Mounting style
B
L
F
G
C
Through-hole/Both ends
tapped common (Standard)
Foot style
Rod side flange style
Head side flange style
Single clevis style
Auto switch
Nil
Without auto switch (Built-in magnet cylinder)
∗ For the applicable auto switch model, refer to the table
below.
∗ Auto switches are shipped together, (but not assembled).
Rod end thread
Bore size
Nil
M
20 mm
20
25 mm
25
32 mm
32
40 mm
40
50 mm
50
63 mm
63
80 mm
80
100 100 mm
Rod end female thread
Rod end male thread
Cylinder stroke (mm)
Refer to page 2 for standard
and intermediate strokes.
Type
Special function
Electrical
entry
Indicator
light
Applicable Auto Switches/Refer to pages 16 to 21 for further information on auto switches.
Wiring
(Output)
Solid state switch
Reed
switch
DC
3-wire (NPN)
5 V,
12 V
3-wire (PNP)
2-wire
12 V
3-wire (NPN)
5 V,
Diagnostic indication
12 V
3-wire (PNP)
(2-color indication) Grommet Yes
24 V
2-wire
12 V
3-wire (NPN)
5 V,
Water resistant
12 V
3-wire (PNP)
(2-color indication)
2-wire
12 V
Magnetic field resistant
2-wire (Non-polar)
—
(2-color indication)
3-wire
5V
—
(NPN equivalent)
Yes
—
Grommet
12 V
2-wire
24 V
No
5 V, 12 V
—
Lead wire length symbols: 0.5 m············Nil
1 m············ M
3 m············ L
5 m············ Z
(Example) M9NW
(Example) M9NWM
(Example) M9NWL
(Example) M9NWZ
Auto switch model Lead wire length (m)
Pre-wired
AC Perpendicular In-line 0.5 1 3 5 None connector
(Nil) (M) (L) (Z) (N)
—
M9N
M9NV
—
M9P
M9PV
—
M9B
M9BV
M9NWV M9NW —
M9PWV M9PW —
—
M9BWV M9BW —
M9NAV M9NA —
M9PA —
M9PAV
M9BAV M9BA —
P3DW — —
—
—
— — —
—
A96
A96V
—
— — —
100 V
A93
A93V
—
— — —
100 V or less A90V
A90
Load voltage
Applicable load
IC circuit
—
IC circuit
—
Relay,
PLC
IC circuit
—
IC circuit
—
—
Relay,
IC circuit PLC
∗ Solid state auto switches marked with “” are produced upon receipt of order.
∗ There are other applicable auto switches other than the listed above. For details, refer to page 11.
∗ For details about auto switches with pre-wired connector, refer to pages 1328 and 1329 in Best Pneumatics No. 2.
Refer to pages 20 and 21 for the D-P3DW type.
∗ Auto switches are shipped together, (but not assembled).
1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
ISO Standards [ISO/21287] Compact Cylinder
Series C55
Specifications
Pneumatic (Non-lube)
Double acting, Single rod
Air
1.5 MPa
1.0 MPa
0.05 MPa (ø20 to ø63), 0.03 MPa (ø80, ø100)
Without auto switch: –10 to 70°C (No freezing)
With auto switch: –10 to 60°C (No freezing)
Rubber bumper on both end
+1.0
0 mm
Through-hole/Both ends tapped common
50 to 500 mm/s
50 to 300 mm/s
Type
Action
Fluid
Proof pressure
Maximum operating pressure
Minimum operating pressure
Ambient and fluid temperature
Cushion
Stroke length tolerance Note)
Caution
Mounting
Be sure to read before handling.
qRefer to back cover for Safety Instructions and
“Handling Precautions for SMC Product”
(M-E03-3) for Actuators and Auto Switches
Precautions.
wThis product should not be used as a stopper.
eUse the PF thread fittings for this cylinder.
Theoretical
Output
OUT
Note) Stroke length tolerance dose not include the amount of bumper change.
Standard Stroke
IN
Unit: N
Bore size Operating Operating pressure (MPa)
(mm) direction
0.3
0.5
0.7
20
25
32
40
50
63
80
100
Bore size (mm)
Standard stroke (mm)
20 to 63
5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 80, 100, 125, 150
80, 100
10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 80, 100, 125
Manufacture of Intermediate Stroke
Description
Dealing with the stroke by the 1 mm interval by using an exclusive body
with the specified stroke
264
Part no.
Refer to “How to Order” for the standard model no. (page at left)
6 to 149
71
118
165
OUT
94
157
220
IN
113
189
IN
ø20 to ø63
ø80, ø100
Piston speed
OUT
147
245
344
Stroke range
Example
IN
181
302
422
OUT
241
402
563
IN
317
528
739
OUT
377
628
880
IN
495
825
1150
OUT
589
982
1370
IN
841
1400
1960
OUT
935
1560
2180
IN
1360
2270
3180
OUT
1510
2520
3520
IN
2150
3580
5010
OUT
2360
3930
5500
Mounting Bracket Part No.
Part no.: C55B32-47
Makes 47 stroke tube
Weight
Without Auto Swtich
Unit: g
Cylinder stroke (mm)
Bore size
(mm)
5
20
111
124 137 150 163 176 189 202 215 228 254 306 357 422 487
25
152
168 183 199 214 230 246 261 277 292 323 386 448 526 603
32
250
273 295 317 339 362 384 406 428 451 495 584 673 785 896
40
315
339 364 388 412 436 461 485 509 533 582 679 776 897 1018
50
497
534 570 607 644 681 718 755 791 828 902 1049 1197 1381 1565
63
677
717 757 797 837 877 917 957 997 1037 1117 1277 1437 1638 1838
10
15
20
25
30
35
40
45
50
60
80
100 125 150
80
— 1164 1223 1281 1339 1398 1456 1514 1573 1631 1748 1981 2214 2506 —
100
— 2213 2295 2377 2459 2541 2623 2705 2787 2870 3034 3362 3690 4101 —
Bore size
(mm)
Foot
20
C55-L020
C55-F020
C55-C020
Bore size
(mm)
5
25
C55-L025
C55-F025
C55-C025
20
113
126 139 152 165 178 191 204 216 229 255 307 359 424 489
32
C55-L032
C55-F032
C55-C032
25
154
170 185 201 217 232 248 263 279 294 325 388 450 528 606
40
C55-L040
C55-F040
C55-C040
32
254
277 299 321 343 366 388 410 432 455 499 588 677 788 900
50
C55-L050
C55-F050
C55-C050
40
319
344 368 392 416 441 465 489 513 537 586 683 780 901 1022
63
C55-L063
C55-F063
C55-C063
50
502
539 575 612 649 686 723 760 796 833 907 1054 1202 1386 1570
80
C55-L080
C55-F080
C55-C080
63
685
725 765 805 845 885 925 965 1005 1045 1125 1285 1445 1645 1845
100
C55-L100
C55-F100
C55-C100
80
— 1188 1246 1305 1363 1421 1480 1538 1596 1654 1771 2004 2238 2529 —
100
— 2248 2330 2412 2494 2577 2659 2741 2823 2905 3069 3397 3726 4136 —
Flange
Single
clevis
• Order two foot brackets per cylinder.
• Parts belonging to each bracket are as follows.
Foot, Flange, Single clevis/Body mounting bolt
With Auto Switch (Built-in magnet)
Unit: g
Cylinder stroke (mm)
10
15
20
25
30
35
40
45
50
60
80
100 125 150
Add each weight of auto switches and mounting brackets when mounting an auto switches.
Refer to pages 16 to 21 for auto switch weight.
2
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series C55
Allowable Lateral Load
Allowable Kinetic Energy
Make sure to operate strictly within the allowable lateral
load range to the rod end.
Make sure to operate strictly within the allowable range
of the load weight and maximum speed.
Operation outside of this range may result in shorter service life or
damage to the device.
Operation outside of this range may cause excessive impact, which
may result in the damage to the device.
Operating pressure: 1 MPa
Lateral load
1000
Stroke
100
Load weight (kg)
Eccentric distance
1000
ø100
ø80
ø63
10
ø50
ø40
ø32
ø25
ø20
Allowable lateral load (N)
1.0
100
0.1
10
100
1000
Maximum piston speed (mm/s)
ø100
ø80
ø63
ø50
ø40
ø32
10
ø25
ø20
1
0
50
100
150
200
Stroke + Eccentric distance (mm)
∗ Refer to Model Selection in Best Pneumatics No.2 for details about model selection procedure.
3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
ISO Standards [ISO/21287] Compact Cylinder
Series C55
Construction
ø20, ø25
!1
M: Rod end
male thread
With auto switch (Built-in magnet)
i r t !2 !4 y e q !3 o w u
ø32 to ø63
!0
With auto switch (Built-in magnet)
!2 r t !4 y i e q !3 o w u
ø80, ø100
!0
With auto switch (Built-in magnet)
!2 r t !4 y i q e !3 w u
Component Parts
No.
1
2
Description
Cylinder tube
Piston
3
Piston rod
4
Collar
5
6
7
8
9
10
11
12
13
14
Retaining ring
Bumper A
Bumper B
Bushing
Wear ring
Magnet
Rod end nut
Rod seal
Piston seal
Tube gasket
!0
Replacement Parts/Seal Kit
Material
Aluminum alloy
Aluminum alloy
Stainless steel
Carbon steel
Aluminum alloy
Aluminum alloy casted
Carbon tool steel
Urethane
Urethane
Bearing alloy
Resin
—
Carbon steel
NBR
NBR
NBR
Note
Hard anodized
Chromated
ø20, ø25
ø32 to ø100 Hard chrome plated
ø20 to ø40 Anodized
ø50 to ø100 Painted after chromated
Phosphate coated
ø20 to ø63
Bore size
(mm)
Kit no.
Contents
20
25
32
40
50
63
80
100
CQ2B20-PS
CQ2B25-PS
CQ2B32-PS
CQ2B40-PS
CQ2B50-PS
CQ2B63-PS
CQ2B80-PS
CQ2B100-PS
Set of nos.
at left
!2, !3, !4
∗ Seal kit includes !2, !3, !4. Order the seal kit,
based on each bore size.
Nickel plated
4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series C55
Mounting Bolt
Should use recommended bolt shown as below table
when mounting the cylinder using through-hole.
Mounting
bolt
OA thread
Note) To install a through-hole type mounting bolt, bore size 20 to 100 mm,
make sure to use the flat washer that is provided.
Mounting Bolt for C55
Model
C(D)55B20-5
-10
-15
-20
-25
-30
-35
-40
-45
-50
-60
-80
-100
-125
-150
C(D)55B25-5
-10
-15
-20
-25
-30
-35
-40
-45
-50
-60
-80
-100
-125
-150
C(D)55B32-5
-10
-15
-20
-25
-30
-35
-40
-45
-50
-60
-80
-100
-125
-150
C
7.2
D Mounting bolt
45 M4 x 45 l
x 50 l
50
x 55 l
55
x 60 l
60
x 65 l
65
x 70 l
70
x 75 l
75
x 80 l
80
x 85 l
85
x 90 l
90
Fix the cylinder by using
the OA thread that are
provided with the cylinder
tube.
10.2
50
55
60
65
70
75
80
85
90
95
M4 x 50 l
x 55 l
x 60 l
x 65 l
x 70 l
x 75 l
x 80 l
x 85 l
x 90 l
x 95 l
Fix the cylinder by using
the OA thread that are
provided with the cylinder
tube.
10
55
60
65
70
75
80
85
90
95
100
110
130
150
M5 x 55 l
x 60 l
x 65 l
x 70 l
x 75 l
x 80 l
x 85 l
x 90 l
x 95 l
x 100 l
x 110 l
x 130 l
x 150 l
Fix the cylinder by using the OA thread
that are provided with the cylinder tube.
Model
C(D)55B40-5
-10
-15
-20
-25
-30
-35
-40
-45
-50
-60
-80
-100
-125
-150
C(D)55B50-5
-10
-15
-20
-25
-30
-35
-40
-45
-50
-60
-80
-100
-125
-150
C(D)55B63-5
-10
-15
-20
-25
-30
-35
-40
-45
-50
-60
-80
-100
-125
-150
C
9
D Mounting bolt
55 M5 x 55 l
x 60 l
60
x 65 l
65
x 70 l
70
x 75 l
75
x 80 l
80
x 85 l
85
x 90 l
90
x 95 l
95
x 100 l
100
x 110 l
110
x 130 l
130
x 150 l
150
Fix the cylinder by using the OA thread
that are provided with the cylinder tube.
8.4
55
60
65
70
75
80
85
90
95
100
110
130
150
M6 x 55 l
x 60 l
x 65 l
x 70 l
x 75 l
x 80 l
x 85 l
x 90 l
x 95 l
x 100 l
x 110 l
x 130 l
x 150 l
Model
C(D)55B80-10
-15
-20
-25
-30
-35
-40
-45
-50
-60
-80
-100
-125
C(D)55B100-10
-15
-20
-25
-30
-35
-40
-45
-50
-60
-80
-100
-125
C
11
D Mounting bolt
70 M8 x 70 l
x 75 l
75
x 80 l
80
x 85 l
85
x 90 l
90
x 95 l
95
x 100 l
100
x 105 l
105
x 110 l
110
x 120 l
120
x 140 l
140
x 160 l
160
Fix the cylinder by using the OA thread
that are provided with the cylinder tube.
13
85
90
95
100
105
110
115
120
125
135
155
175
M8 x 85 l
x 90 l
x 95 l
x 100 l
x 105 l
x 110 l
x 115 l
x 120 l
x 125 l
x 135 l
x 155 l
x 175 l
Fix the cylinder by using the OA thread
that are provided with the cylinder tube.
Fix the cylinder by using the OA thread
that are provided with the cylinder tube.
9.4
60
65
70
75
80
85
90
95
100
105
115
135
155
M6 x 60 l
x 65 l
x 70 l
x 75 l
x 80 l
x 85 l
x 90 l
x 95 l
x 100 l
x 105 l
x 115 l
x 135 l
x 155 l
Fix the cylinder by using the OA thread
that are provided with the cylinder tube.
5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
ISO Standards [ISO/21287] Compact Cylinder
Dimensions
Series C55
[First angle projection]
ø20, ø25
Auto switch
Flat washer
4 pcs.
2
øI
ø20
OA (4 positions)
(The same four-place size)
2 x 4 x RA
5.5
H thread effective depth C
M
F
øD
T
øN through (4 positions)
(The same four-place size)
Q
øOB counterbore RB (4 positions)
(The same four-place size)
E
M5 x 0.8 (2 positions)
Port size
K
(RB)
M
L
B + Stroke
E
A + Stroke
ø25
M: Rod end male thread
H
øD
Width across flats K
Hexagon width
across flats B1
Rod end nut
H1
C
X
L1
Rod End Male Thread
(mm)
Bore size
(mm)
B1
C
D
H
H1
K
L1
X
20
25
13
13
14
14
10
12
M8 x 1.25
M8 x 1.25
5
5
8
10
22
22
16
16
Basic Style
(mm)
Bore size
(mm)
A
B
C
D
E
F
H
I
K
L
M
N
OA
OB
Q
RA
RB
T
20
25
43
45
37
39
10
10
10
12
36
40
5.5
5.5
M6 x 1.0
M6 x 1.0
43
48
8
10
6
6
22
26
4.5
4.5
M5 x 0.8
M5 x 0.8
7.5
7.5
13
13
10
10
5
5
0.8
0.8
6
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series C55
Dimensions
[First angle projection]
ø32 to ø63
øD
Flat washer
4 pcs.
J
øI
OA (4 positions)
(The same four-place size)
2 x 4 x RA
L
H thread effective depth C
Z
øN through (4 positions)
(The same four-place size)
F
M
Q
T
øOB counterbore RB (4 positions)
(The same four-place size)
Auto switch
E
G1/8 (2 positions)
Port size
K
(RB)
M
B + Stroke
E
A + Stroke
M: Rod end male thread
H
øD
Width across flats K
Hexagon width
across flats B1
Rod end nut
H1
C
X
L1
Rod End Male Thread
(mm)
Bore size
(mm)
B1
C
D
H
H1
K
L1
X
32
40
50
63
17
17
19
19
16.5
16.5
19.5
19.5
16
16
20
20
M10 x 1.25
M10 x 1.25
M12 x 1.25
M12 x 1.25
6
6
7
7
14
14
17
17
26
26
30
30
19
19
22
22
Basic Style
(mm)
Bore size
(mm)
A
B
C
D
E
32
40
50
63
51
52
53
57
44
45
45
49
12
12
16
16
16
16
20
20
46
52
64
74
F
H
8.5 M8 x 1.25
9.5 M8 x 1.25
10.5 M10 x 1.5
14.5 M10 x 1.5
I
J
K
L
M
N
OA
OB
Q
RA
RB
T
Z
59
67
82
96
2
3
2
3
14
14
17
17
7
7
8
8
32.5
38
46.5
56.5
5.5
5.5
6.6
6.6
M6 x 1.0
M6 x 1.0
M8 x 1.25
M8 x 1.25
9
9
10.5
10.5
14.5
14.5
13.5
15.5
11
11
15
15
5
5
5
5
1
1
1.6
1.6
15
17
17
17
7
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
ISO Standards [ISO/21287] Compact Cylinder
Dimensions
Series C55
[First angle projection]
ø80, ø100
M12 x 1.75 effective depth 21
Auto switch
Q
F
øI
M10 x 1.5 effective depth 15 (4 positions)
(The same four-place size)
10
B + Stroke
A + Stroke
ø8.4 through (4 positions)
(The same four-place size)
C
Z
M
E
øD
C
2 x G1/8
K
M
2.5
E
ø13.5 counterbore 5 (4 positions)
(The same four-place size)
M: Rod end male thread
Width across flats K
M16 x 1.5
øD
Hexagon width
across flats 24
10
25
28
38
B + Stroke
A1 + Stroke
Basic Style
Bore size
(mm)
(mm)
A
B
C
D
80
64
54
11
25
100
77
67
14
30
E
Rod End Male Thread (mm)
Bore size
(mm)
F
I
K
M
Q
Z
A1
91
15
121
22
72
19
36
80
92
111
18
145
27
89
26
42
100
106.5
8
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series C55
Mounting Bracket
[First angle projection]
Foot bracket
Flange bracket
Hexagon socket head cap screw
(Accessory)
FL
4 x øFD
2 x øFD
FZ
2 x øLD
FX
M
Hexagon socket
head cap screw
(Accessory)
øD
1
H1
LT
L
LH
M/2
R
M
LX
LZ
Y X
FY
FT
M
FV
ø32 to ø100
ø20, ø25
(mm)
(mm)
Bore size
(mm)
L
LD
LH
LT
20
25
32
40
50
63
80
100
22
22
24.5
26
31
31
38.5
45
7
7
7
10
10
10
12
14.5
27
29
33.5
38
45
50
63
74
4
4
4
4
5
5
6
6
LX
LZ
36
22
40
26
46
32
52
36
64
45
74
50
96
63
75 116
M
R
X
Y
Hexagon
socket
head cap
screw
22
26
32.5
38
46.5
56.5
72
89
8
10
15
17.5
20
22.5
—
—
16
16
16
18
21
21
26
27
7
7
7
9
9
9
11
13
M5
M5
M6
M6
M8
M8
M10
M10
Bore size
(mm)
D
M
FD
FL
FT
FX
FY
FZ
Hexagon
socket
head cap
screw
20
25
32
40
50
63
80
100
16
16
30
35
40
45
45
55
22
26
32.5
38
46.5
56.5
72
89
6.6
6.6
7
9
9
9
12
14
2.8
2.8
5
5
6
6
8
8
38 55
8
38 60
8
50 64
10
55 72
10
70 90
12
80 100
12
16 100 126
16 120 150
—
—
32
36
45
50
63
75
68
73
79
90
110
120
153
178
M5
M5
M6
M6
M8
M8
M10
M10
FV
Single clevis bracket
Hexagon socket head cap screw
(Accessory)
CL
M
CZ
øCD hole H9
CX -0.2
-0.6
M
CU
CZ
CW RR
(mm)
Bore size
CDH9 CL
(mm)
20
25
32
40
50
63
80
100
8
8
10
12
12
16
16
20
3
3
5.5
5.5
6.5
6.5
10
10
CU
CW
CX
CZ
M
RR
Hexagon
socket
head cap
screw
12
12
12
15
15
20
20
25
20
20
22
25
27
32
36
41
16
16
26
28
32
40
50
60
35
40
45
51
64
74
94
113
22
26
32.5
38
46.5
56.5
72
89
9
9
9.5
12
12
16
16
20
M5
M5
M6
M6
M8
M8
M10
M10
9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
ISO Standards [ISO/21287] Compact Cylinder
Proper Auto Switch Mounting Position (Detection at Stroke End) and Its Mounting Height
Reed auto switch
Solid state auto switch
D-A9
D-M9
D-M9W
D-M9AL
D-P3DW
Series C55
[First angle projection]
B
W
B
W
A
≈ Hs
ø20, ø25
A
≈ Hs
ø32, ø40, ø50, ø63, ø80, ø100
∗ Figures in the table below are used as a reference when mounting the auto switches for stroke end detection.
In the case of actually setting the auto switches, adjust them after confirming their operation.
(mm)
Auto switch
model
Bore size (mm)
20
25
32
40
50
63
80
100
D-M9
D-M9W
D-A9
A
11.5
12.5
14.5
13
9.5
10.5
16.5
24.5
B
5.5
7.5
9.5
12
15.5
18.5
17.5
22.5
The dimension inside ( ) is for D-A96.
W
1 (3.5)
3 (5.5)
5 (7.5)
7.5 (10)
11 (13.5)
14 (16.5)
13 (15.5)
18 (20.5)
A
15.5
16.5
18.5
17
13.5
14.5
20.5
28.5
B
9.5
11.5
13.5
16
19.5
22.5
21.5
26.5
D-M9AL
W
-0.5
1.5
3.5
6
9.5
12.5
11.5
16.5
A
15.5
16.5
18.5
17
13.5
14.5
20.5
28.5
B
9.5
11.5
13.5
16
19.5
22.5
21.5
26.5
D-P3DW
W
-2.5
-0.5
1.5
4
7.5
10.5
9.5
14.5
A
6.0
7
9.5
8
4.5
5.5
11.5
19.5
B
0.5
2.5
4
7
10.5
13.5
12.5
17.5
W
-3.0
-1
1
3.5
7
10
9
14
Hs
30
32
35
38
44
49
57.5
67.5
Negative figures in the table W indicate an auto switch is mounted outward from the edge of the cylinder body.
Reed auto switch
Solid state auto switch
D-A9V
D-M9V
D-M9WV
D-M9AVL
A
B
≈ Hs
ø20, ø25
A
B
≈ Hs
ø32, ø40, ø50, ø63, ø80, ø100
∗ Figures in the table below are used as a reference when mounting the auto
switches for stroke end detection. In the case of actually setting the auto switches,
adjust them after confirming their operation.
(mm)
Auto switch
model
Bore size (mm)
20
25
32
40
50
63
80
100
D-A9V
A
11.5
12.5
14.5
13
9.5
10.5
16.5
24.5
B
5.5
7.5
9.5
12
15.5
18.5
17.5
22.5
Hs
22
24
27
30
36
41
49.5
60
A
15.5
16.5
18.5
17
13.5
14.5
20.5
28.5
D-M9V
D-M9WV
D-M9AVL
B
Hs
9.5
24
11.5
26
13.5
29
16
32
19.5
38
22.5
43
21.5
52
26.5
62
10
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series C55
The Number of Surfaces and Grooves Where an Auto Switch Can Be Mounted (As Direct Mounting)
The number of the surfaces and grooves where the auto switch can be mounted, by switch type, are shown in the table below.
Piping port
A
D
Auto switch
model
Bore size
(mm)
B
D-A9, M9
A
(Mounting
groove no.)
(Mounting
groove no.)
(1)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
32
Mounting the D-P3DW on a ø20 to ø25 port
surface interferes with the fitting, so it needs to
be mounted on a place other than the port
surface.
For ø32 to ø100, if the corner of the fitting
hexagon interferes with the D-P3DW Series,
adjust the tightening of the fitting to eliminate
the interference.
Also, in the case of interference with an elbow
type fitting, direct the port of the fitting away
from the D-P3DW Series.
If you have any other questions, please contact
SMC.
D
(Mounting
groove no.)
25
C
C
(Mounting
groove no.)
20
View from
piston rod end
B
D-P3DW
40
50
63
80
100
A
(Mounting
groove no.)
(2)
(2)
B
C
D
(Mounting
groove no.)
(Mounting
groove no.)
(Mounting
groove no.)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
Operating Range
(mm)
20
9
25
9
32
9
Bore size
40
50
9
9
D-M9(V)
D-M9W(V)
D-M9A(V)
5
4.5
5
4
D-P3DW
5
5.5
5.5
5.5
Auto switch model
D-A9(V)
63
10.5
80
14
100
10.5
4.5
5
10
8
5.5
6.5
9
7
∗ The operating ranges are provided as guidelines including hystereses and are not guaranteed
values (assuming approximately ±30% variations).
They may vary significantly with ambient environments.
Minimum Auto Switch Mounting Stroke
(mm)
Bore size
(mm)
20
25
32, 40, 50
63
80, 100
Auto switch model
No. of auto switch
mounted
2 pcs.
1 pc.
2 pcs.
1 pc.
2 pcs.
1 pc.
2 pcs.
1 pc.
2 pcs.
1 pc.
D-A9
D-A9V
D-M9
D-M9W
D-M9A
D-M9V
D-M9WV
D-M9AV
D-P3DW
10
10
10
10
10
10
10
5
10
10
10
5
10
5
10
5
10
5
10
5
15
15
10
10
10
10
10
5
15
15
15
15
15
15
15
15
15
15
15
15
5
5
5
5
5
5
5
5
5
5
10
5
10
5
10
5
10
5
10
5
10
10
10
10
10
10
10
10
10
10
15
15
15
15
10
10
10
10
10
10
Besides the models listed in “How to Order,” the following auto switches are applicable.
∗ Normally closed (NC = b contact), solid state auto switch (D-F9G/F9H type, and D-F8 type) are also available. For details, refer to Best Pneumatics
No.2.
∗ For solid state auto switches, auto switches with a pre-wired connector are also available. Refer to Best Pneumatics No.2 for details.
11
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
ISO Standards [ISO/21287] Compact Cylinder
Series C55
Mounting of Auto Switch/Direct Mounting Style
To mount auto switches, follow the instruction illustrated below.
<Applicable auto switch>
<Applicable auto switch>
Solid state······D-M9(V)
D-M9W(V)
D-M9A(V)
Reed···············D-A(V)
Solid state······D-P3DW
ø20 to ø100
ø20 to ø100
Hexagon socket head cap screw
(M2.5 x 9 L)
Watchmakers screw driver
Protrusion
Hexagon socket head cap screw
(M2.5 x 6 L)
Auto switch mounting screw
Auto switch
mounting bracket Note)
Auto switch
Note) When the auto switch
mounting bracket is
ordered by its part
number, it includes all
the bracket and bolts
in the above chart.
Applicable auto switch Auto switch mounting bracket part no.
Use a watchmakers screwdriver with a handle 5 to 6 mm in diameter
when tightening the auto switch mounting screw.
Tightening Torque of Auto Switch
Mounting Screws
Auto switch model
Tightening torque
D-M9(V)
D-M9W(V)
D-M9A(V)L
0.05 to 0.15
D-A9(V)
0.10 to 0.20
(N . m)
D-P3DW
BQ3-032S
q Insert the protrusion on the bottom of the auto switch into the mating
part of the auto switch mounting bracket and fix the auto switch and
the auto switch mounting bracket temporarily by tightening the
hexagon socket head cap screw (M2.5 x 9 L) 1 to 2 turns.
w Insert the temporarily tightened mounting bracket into the mating
groove of the cylinder/actuator, and slide the auto switch onto the
cylinder/actuator through the groove.
e Check the detecting position of the auto switch and fix the auto
switch firmly with the hexagon socket head cap screw (M2.5 x 6 L,
M2.5 x 9 L).∗
r If the detecting position is changed, go back to step w.
∗ The hexagon socket head cap screw (M2.5 x 6 L) is used to fix the
mounting bracket and cylinder/actuator.
This enables the replacement of the auto switch without adjusting
the auto switch position.
Note 1) Ensure that the auto switch is covered with the mating groove
to protect the auto switch.
Note 2) The torque for tightening the hexagon socket head cap screw
(M2.5 x 6 L, M2.5 x 9 L) is 0.2 to 0.3 N·m.
Note 3) Tighten the hexagon socket head cap screws evenly.
Note 4) For ø80 or ø100, in the case of mounting the auto switch of
the D-P3DW Series onto the port surface, if the corner of
the fitting hexagon interferes with the auto switch, adjust the
tightening of the fitting to eliminate the interference.
In the case of interference with an elbow type fitting, direct
the port of the fitting away from the auto switch.
Such interference must be avoided especially when selecting
a speed controller with fittings or speed exhaust controller,
etc.
Note 5) When the cylinder with auto switches is ordered, the body of
the cylinder/auto switch and auto switch mounting bracket
are shipped together.
12
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Prior to Use
Auto Switches Common Specifications 1
Specific Product Precautions
Before handling auto switches, refer to “Handling Precautions for SMC Products” (M-E03-3) for Auto Switches
Precautions.
Auto Switches Common Specifications
Type
1.2 ms
Solid state auto switch
1 ms or less ∗
300 m/s2
1000 m/s2
Reed auto switch
Operating time
Impact resistance
50 MΩ or more at 500 VDC Mega (Between lead wire and case)
Insulation resistance
1500 VAC for 1 minute
(Between lead wire and case)
Withstand voltage
1000 VAC for 1 minute
(Between lead wire and case)
–10 to 60°C
Ambient temperature
IEC60529 Standard IP67
Enclosure
∗ The operating time for the D-P3DW is 40 ms or less.
Lead Wire
Lead wire length indication
(Example)
D-M9BW L
Lead wire length
Nil
M
L
Z
0.5 m
1m
3m
5m
Note 1) Lead wire length Z: 5 m
Applicable auto switches
Solid state auto switch: Manufactured upon receipt of order as standard.
Note 2) The standard lead wire length for water resistant 2-color indication solid state auto switches is 3 m.
(D-M9A(V)L can be used with a lead wire of 0.5 m and 3 m.)
Note 3) 1 m (M): D-M9(V), M9W(V), M9A(V)L only.
Note 4) Lead wire length tolerance
Lead wire length
0.5 m
1m
3m
5m
Tolerance
±15 mm
±30 mm
±90 mm
±150 mm
13
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Prior to Use
Auto Switches Common Specifications 2
Specific Product Precautions
Before handling auto switches, refer to “Handling Precautions for SMC Products” (M-E03-3) for Auto Switches
Precautions.
Auto Switch Hysteresis
Contact Protection Box: CD-P11, CD-P12
Hysteresis is the distance between the position at which piston
movement operates an auto switch to the position at which reverse
movement turns the switch off. This hysteresis is included in part of
the operating range (one side).
<Applicable switch models>
D-A9/A9V
The auto switches above do not have a built-in contact protection
circuit. A contact protection box is not required for solid state auto
switches due to their construction.
q Where the operation load is an inductive load.
w Where the wiring length to load is greater than 5 m.
e Where the load voltage is 100 VAC.
Therefore, use a contact protection box with the switch for
any of the above cases:
The contact life may be shortened (due to permanent energizing
conditions.)
When the load voltage is increased by more than 10% to the rating
of applicable auto switches above, use a contact protection box
(CD-P11) to reduce the upper limit of the load current by 10% so
that it can be set within the range of the load current range, 110
VAC.
Auto switch
Switch
operating
position
(ON)
Note)
Hysteresis Reed auto switch: 2 mm or less
Solid state auto switch: 1 mm or less
Switch
operating
position
(OFF)
Note) Hysteresis may fluctuate due to the operating environment.
Please contact SMC if hysteresis causes an operational problem.
Contact Protection Box Specifications
Part no.
CD-P11
Load voltage
100 VAC or less
200 VAC
Max. load current
25 mA
12.5 mA
CD-P12
24 VDC
50 mA
∗ Lead wire length — Auto switch connection side 0.5 m
Load connection side 0.5 m
Contact Protection Box Internal Circuit
CD-P11
OUT Brown
Surge absorber
Choke
coil
~
OUT Blue
CD-P12
Zener diode
Choke
coil
OUT (+) Brown
OUT (–) Blue
Contact Protection Box/Dimensions
Contact Protection Box Connection
To connect a switch unit to a contact protection box, connect the lead
wire from the side of the contact protection box marked SWITCH to
the lead wire coming out of the switch unit. Keep the switch as close
as possible to the contact protection box, with a lead wire length of no
more than 1 meter.
14
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Prior to Use
Auto Switches Connection and Example
Basic Wiring
Solid state 3-wire, NPN
Solid state 3-wire, PNP
2-wire (Solid state)
Brown
Brown
Brown
2-wire (Reed switch)
Brown
Load
Load
Main
curcuit
of switch
Main
curcuit
of switch
Black
Main
curcuit
of switch
Black
Load
Blue
Load
Indicator
protection
circuit,
etc.
Blue
~
Blue
Blue
Brown
Brown
(Power supply for switch and load are separate)
Brown
Load
Main
curcuit
of switch
Indicator
protection
circuit,
etc.
Main
curcuit
of switch
Black
Load
~
Load
Blue
Blue
Blue
Example of Connection with PLC (Programmable Logic Controller)
• Source input specifications
3-wire, PNP
• Sink input specifications
3-wire, NPN
Black
Auto switch
Black
Input
Brown
Connect according to the applicable PLC
input specifications, as the connection
method will vary depending on the PLC
input specifications.
Input
Brown
Auto switch
Blue
Blue
COM
COM
PLC internal circuit
PLC internal circuit
2-wire
2-wire
Brown
Input
Auto switch
Blue
Input
Brown
COM
Auto switch
Blue
COM
PLC internal circuit
PLC internal circuit
Example of AND (Series) and OR (Parallel) Connection
• 3-wire
AND connection for NPN output
(Using relays)
Auto switch 1
Auto switch 2
Brown
Black
Relay
Blue
AND connection for NPN output
(Performed with auto switches only)
Load
Relay
contact
Brown
Black
Relay
Blue
Auto switch 1
Auto switch 2
OR connection for NPN output
Brown
Black
Load
Blue
Auto switch 1
Brown
Black
Blue
Auto switch 2
Brown
Black
Blue
Load
Brown
Black
Blue
The indicator lights will light up when
both auto switches are turned ON.
• 2-wire
2-wire with 2-switch AND connection
Brown
Auto switch 1
Auto switch 2
Blue
Brown
Blue
Load
When two auto switches
are connected in series, a
load may malfunction
because the load voltage
will decline when in the ON
state.
The indicator lights will light
up when both of the auto
switches are in the ON
state.
2-wire with 2-switch OR connection
Brown
Auto switch 1
Auto switch 2
Blue
Brown
Load
(Solid state auto switch)
(Reed auto switch)
When two auto switches
are connected in parallel,
malfunction may occur
because the load voltage
will increase when in the
OFF state.
Because there is no
current leakage, the load
voltage will not increase
when turned OFF.
However, depending on
the number of auto
switches in the ON state,
the indicator lights may
sometimes grow dim or
not light up, due to the
dispersion and reduction
of the current flowing to
the auto switches.
Blue
Load voltage at ON = Power supply voltage – Residual voltage x 2 pcs.
= 24 V – 4 V x 2 pcs.
= 16 V
Load voltage at OFF = Leakage current x 2 pcs. x Load impedance
= 1 mA x 2 pcs. x 3 kΩ
=6V
Example: Power supply is 24 VDC
Internal voltage drop in auto switch is 4 V.
Example: Load impedance is 3 kΩ.
Leakage current from auto switch is 1 mA.
15
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Solid State Auto Switch
Direct Mounting Style
D-M9N(V)/D-M9P(V)/D-M9B(V)
For details about certified products
conforming to international standards,
visit us at www.smcworld.com.
Auto Switch Specifications
Grommet
PLC: Programmable Logic Controller
2-wire load current is reduced
(2.5 to 40 mA).
Flexibility is 1.5 times greater than
the conventional model
(SMC comparison).
Using flexible cable as standard spec.
D-M9, D-M9V (With indicator light)
D-M9N
D-M9NV
D-M9B
D-M9BV
D-M9P
D-M9PV
Auto switch model
Electrical entry direction
In-line Perpendicular In-line Perpendicular In-line Perpendicular
Wiring type
2-wire
3-wire
NPN
Output type
PNP
—
Applicable load
IC circuit, Relay, PLC
24 VDC relay, PLC
Power supply voltage
5, 12, 24 VDC (4.5 to 28 V)
—
Current consumption
10 mA or less
—
Load voltage
24 VDC (10 to 28 VDC)
—
28 VDC or less
Load current
2.5 to 40 mA
40 mA or less
Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA)
4 V or less
Leakage current
0.8 mA or less
100 μA or less at 24 VDC
Indicator light
Red LED illuminates when turned ON.
Standard
CE marking
Lead wires — Oilproof flexible heavy-duty vinyl cord: ø2.7 x 3.2 ellipse, 0.15 mm2, 2 cores
(D-M9B(V)), 3 cores (D-M9N(V), D-M9P(V))
Note 1) Refer to page 13 for solid state auto switch common specifications.
Note 2) Refer to page 13 for lead wire lengths.
Weight
Unit: g
Auto switch model
Caution
Precautions
Fix the auto switch with the existing screw
installed on the auto switch body.
The auto switch may be damaged if a screw
other than the one supplied is used.
D-M9N(V)
8
14
41
68
0.5
1
3
5
Lead wire length
(m)
Dimensions
D-M9
M2.5 x 4 l
Slotted set screw
2.7
4
2.8
22
3.2
Main circuit
of switch
Indicator light
2.6
OUT
Black
DC (–)
Blue
6
D-M9P, D-M9PV
OUT
Black
Most sensitive position
D-M9V
M2.5 x 4 l
Slotted set screw
2
2.8
4
DC (–)
Blue
Indicator light
8
3.2
4.6
Main circuit
of switch
DC (+)
Brown
D-M9B(V)
7
13
38
63
Unit: mm
Auto Switch Internal Circuit
D-M9N, D-M9NV
DC (+)
Brown
D-M9P(V)
8
14
41
68
D-M9B, D-M9BV
20
2.7
4
OUT (–)
Blue
2.6
9.5
Main circuit
of switch
OUT (+)
Brown
6 Most sensitive position
16
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2-Color Indication Type Solid State Auto Switch
Direct Mounting Style
D-M9NW(V)/D-M9PW(V)/D-M9BW(V)
For details about certified products
conforming to international standards,
visit us at www.smcworld.com.
Auto Switch Specifications
Grommet
PLC: Programmable Logic Controller
2-wire load current is reduced
(2.5 to 40 mA).
Flexibility is 1.5 times greater than the
conventional model (SMC comparison).
Using flexible cable as standard spec.
A proper operating range can be
determined by the color of the light.
(Red → Green ← Red)
D-M9W, D-M9WV (With indicator light)
Auto switch model D-M9NW D-M9NWV D-M9PW D-M9PWV D-M9BW D-M9BWV
In-line Perpendicular In-line Perpendicular In-line Perpendicular
Electrical entry direction
3-wire
2-wire
Wiring type
NPN
PNP
—
Output type
24 VDC relay, PLC
IC circuit, Relay, PLC
Applicable load
—
5, 12, 24 VDC (4.5 to 28 V)
Power supply voltage
—
10 mA or less
Current consumption
24 VDC (10 to 28 VDC)
—
Load voltage
28 VDC or less
40 mA or less
2.5 to 40 mA
Load current
4 V or less
Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA)
100 μA or less at 24 VDC
0.8 mA or less
Leakage current
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.
CE marking
Standard
Caution
Precautions
Fix the auto switch with the existing screw
installed on the auto switch body.
The auto switch may be damaged if a screw
other than the one supplied is used.
Auto Switch Internal Circuit
D-M9NW, D-M9NWV
Main circuit
of switch
DC (+)
Brown
Lead wires — Oilproof flexible heavy-duty vinyl cord: ø2.7 x 3.2 ellipse, 0.15 mm2, 2 cores
(D-M9BW(V)), 3 cores (D-M9NW(V), D-M9PW(V))
Note 1) Refer to page 13 for solid state auto switch common specifications.
Note 2) Refer to page 13 for lead wire lengths.
Weight
Unit: g
Auto switch model
D-M9NW(V)
8
14
41
68
0.5
1
3
5
Lead wire length
(m)
OUT
Black
D-M9PW(V)
8
14
41
68
Dimensions
Unit: mm
D-M9W
DC (–)
Blue
M2.5 x 4 l
Slotted set screw
D-M9PW, D-M9PWV
Indicator light
4
2.8
OUT
Black
2.7
2.6
DC (+)
Brown
3.2
22
DC (–)
Blue
6 Most sensitive position
D-M9BW, D-M9BWV
OUT (+)
Brown
D-M9WV
Indicator light
Main circuit
of switch
M2.5 x 4 l
Slotted set screw
8
2
3.2
2.8
4
OUT (–)
Blue
4.6
Main circuit
of switch
D-M9BW(V)
7
13
38
63
Indicator light / Display method
20
2.7
ON
Operating range
Green
Red
2.6
Display
Red
9.5
OFF
4
Proper operating range
6 Most sensitive position
17
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Water Resistant 2-Color Indication Type
Solid State Auto Switch: Direct Mounting Style
D-M9NA(V)/D-M9PA(V)/D-M9BA(V)
Auto Switch Specifications
Grommet
PLC: Programmable Logic Controller
Water (coolant) resistant type
2-wire load current is reduced
(2.5 to 40 mA).
A proper operating range can be
determined by the color of the light.
(Red → Green ← Red)
Using flexible cable as standard spec.
D-M9A, D-M9AV (With indicator light)
D-M9NA D-M9NAV D-M9PA D-M9PAV D-M9BA D-M9BAV
In-line Perpendicular In-line Perpendicular In-line Perpendicular
3-wire
2-wire
NPN
PNP
—
24 VDC relay, PLC
IC circuit, Relay, PLC
—
5, 12, 24 VDC (4.5 to 28 V)
—
10 mA or less
24 VDC (10 to 28 VDC)
28 VDC or less
—
40 mA or less
2.5 to 40 mA
0.8 V or less at 10 mA (2 V or less at 40 mA)
4 V or less
100 μA or less at 24 VDC
0.8 mA or less
Operating range .......... Red LED illuminates.
Proper operating range .......... Green LED illuminates.
Auto switch model
Electrical entry direction
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
Caution
CE marking
Standard
Precautions
Fix the auto switch with the existing screw
installed on the auto switch body.
The auto switch may be damaged if a screw
other than the one supplied is used.
Lead wires — Oilproof flexible heavy-duty vinyl cord: ø2.7 x 3.2 ellipse, 0.15 mm2, 2 cores
(D-M9BA(V)), 3 cores (D-M9NA(V), D-M9PA(V))
Note 1) Refer to page 13 for solid state auto switch common specifications.
Note 2) Refer to page 13 for lead wire lengths.
Weight
Auto Switch Internal Circuit
D-M9NA, D-M9NAV
Main circuit
of switch
DC (+)
Brown
Unit: g
Auto switch model
Lead wire length
(m)
OUT
Black
D-M9BA(V)
7
13
38
63
D-M9PA(V)
8
14
41
68
D-M9NA(V)
8
14
41
68
0.5
1
3
5
Dimensions
DC (–)
Blue
Unit: mm
M2.5 x 4 l
Slotted set screw
D-M9A
D-M9PA, D-M9PAV
Indicator light
4
24
4
3.2
0.2
OUT
Black
2.7
SMC
2.8
3
DC (–)
Blue
6
D-M9BA, D-M9BAV
Most sensitive position
D-M9AV
Main circuit
of switch
OUT (+)
Brown
M2.5 x 4 l
Slotted set screw
8
2
3.2
4
OUT (–)
Blue
SMC
2.8
Indicator light/Display method
ON
Operating
range
Indicator light
4.6
Main circuit
of switch
DC (+)
Brown
2.7
22
Red
Proper operating range
4
Green
9.3
Display
Red
2.6
OFF
6
Most sensitive position
18
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Reed Auto Switch
Direct Mounting Style
D-A90(V)/D-A93(V)/D-A96(V)
For details about certified products
conforming to international standards,
visit us at www.smcworld.com.
Auto Switch Specifications
Grommet
PLC: Programmable Logic Controller
D-A90, D-A90V (Without indicator light)
Auto switch model
D-A90, D-A90V
Applicable load
IC circuit, Relay, PLC
Load voltage
24 V
Maximum load current
AC
DC
48 V
or less
AC
DC
100 V AC
DC or less
or less
40 mA
50 mA
20 mA
Contact protection circuit
None
Internal resistance
1 Ω or less (Including lead wire length of 3 m)
Standard
CE marking
D-A93, D-A93V, D-A96, D-A96V (With indicator light)
Caution
Precautions
Auto switch model
D-A93, D-A93V
Applicable load
Relay, PLC
Load voltage
Fix the auto switch with the existing screw
installed on the auto switch body.
The auto switch may be damaged if a screw
other than the one supplied is used.
Load current range and
Maximum load current (3)
D-A96, D-A96V
IC circuit
24 VDC
100 VAC
4 to 8 VDC
5 to 40 mA
5 to 20 mA
20 mA
Contact protection circuit
None
D-A93: 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA)
Internal voltage drop
D-A93V: 2.7 V or less
Red LED illuminates when turned ON.
Indicator light
OUT(±)
Brown
OUT ( )
Blue
• Lead wires
D-A90(V)/D-A93(V)—Oilproof heavy-duty vinyl cord, ø2.7, 0.18 mm2 x 2 cores (Brown, Blue), 0.5 m
D-A96(V)—Oilproof heavy-duty vinyl cord, ø2.7, 0.15 mm2 x 3 cores (Brown, Black, Blue), 0.5 m
Note 1) Refer to page 13 for reed auto switch common specifications.
Note 2) Refer to page 13 for lead wire lengths.
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator
light will not be possible where the output signal is less than 2.5 mA. However, there is no
problem in terms of contact output, when an output signal exceeds 1 mA or more.
Weight
Unit: g
Model
D-A93, A93V
LED
Brown
Contact
protection
box
CD-P11
CD-P12
Reed switch
Resistor
Zener diode
OUT (+)
Brown
OUT (–)
Blue
Blue
Lead wire length
(m)
D-A90
D-A90V
D-A93
D-A93V
D-A96
D-A96V
0.5
6
6
6
6
8
8
3
30
30
30
30
41
41
Dimensions
Unit: mm
D-A90/D-A93/D-A96
2.8
2
ø2.7
Contact
protection
box
CD-P11
CD-P12
±
Reed switch
D-A90, A90V
CE marking
Standard
4.5
Auto Switch Internal Circuit
4
D-A96, A96V
LED
DC (+)
Brown
Reed switch
Reverse
OUT
current
Black
prevention
diode
DC (–)
Blue
Load
DC
power supply
(–)
24.5
(22)
M2.5 x 4 L
Slotted set screw
(+)
Resistor
0.8 V or less
10
D-A90V/D-A93V/D-A96V
Note 1) Operating load is an induction load.
Note 2) Wiring to the load is 5 m or longer.
Note 3) Load voltage is 100 VAC.
Use the contact protection box in any of the
above listed situations. The contact point life
may decrease. (Refer to page 14 for contact
protection box.)
Indicator light
D-A90 without indicator light
Most sensitive
position
( ): dimensions for D-A96.
22
M2.5 x 4 L
Slotted set screw
4.5
6
Indicator light
D-A90V without indicator light
5.1
9.1
ø2.7
2
4
10
Most sensitive position
19
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Magnetic Field Resistant 2-Color Display
Solid State Auto Switch
D-P3DWSC/D-P3DWSE
(Electrical entry: Pre-wired connector)
It is possible to use in an
environment which generates
a magnetic field disturbance
(AC magnetic field).
A proper operating range can
be determined by the color of
the light.
(Red → Green ← Red)
For details about certified products
conforming to international standards,
visit us at www.smcworld.com.
Auto Switch Specifications
PLC: Programmable Logic Controller
D-P3DWSC/E (With indicator light)
Auto switch model
D-P3DWSC
D-P3DWSE
24 VDC relay, PLC
Applicable load
Load voltage
24 VDC (20 to 28 VDC)
Load current
6 to 40 mA
5 V or less
Internal voltage drop
1 mA or less at 24 VDC
Leakage current
Operating time
40 ms or less
Indicator light
Operating range······Red LED illuminates.
Proper operating range······Green LED illuminates.
CE marking, UL (CSA), RoHS
Standards
• Lead wire — Oilproof heavy-duty vinyl cable, ø4.8, 0.5 mm2, 2 cores
• Impact resistance — Switch: 1000 m/s2, Connector: 300 m/s2
• Insulation resistance — 50 MΩ or more at 500 VDC Mega (between lead wire and case)
• Withstand voltage — 1000 VAC for 1 minute (between lead wire and case)
• Ambient temperature — –10 to 60°C
• Enclosure — IEC60529 standard IP67
• Polarity: Non-polar
Precautions
For single-phase AC welding machines
If it is used for current inverter welders
(including rectifying type) and condenser
type welders, the magnetic field resistance is
reduced. Please contact SMC regarding the
performance.
Switch
main circuit
Auto Switch Internal Circuit
D-P3DWSC
NO.3 (OUT ±)
NO.4 (OUT ±)
Magnetic Field Resistance
If the current of the AC welding machine is 16000 A or lower, the auto switch can be used, even if the
distance between the welding conductor (gun cable) and the cylinder/actuator or auto switch is 0 mm.
Please contact SMC when the AC welding current exceeds 16000 A.
Weight
Unit: g
Auto switch model
Lead wire length (m)
D-P3DWSC
D-P3DWSE
0.3
23
Dimensions
Unit: mm
Body
ø4.8
Caution
6
ø14
Indicator light
D-P3DWSE
ø2.8 mounting hole
Switch
main circuit
3
29
300
42.5
1
NO.1 (OUT ±)
3.2
11
NO.4 (OUT ±)
Most sensitive Heat shrink tube Note)
10.5 position
Note) A white color heat
shrink tube is attached
to the D-P3DWSE
type only.
Indicator light/Display method
ON
Operating
range
OFF
Display
Red
Green
Auto switch mounting bracket
(For round groove mounting:
BQ3-032S)
4.7
Red
Auto switch mounting bracket
(For square groove mounting:
BMG5-025S)
4.7
(29)
(29)
Proper operating range
2
1
3
4
Connector pin assignment
4
4
13.7 Most sensitive
(15.2) position
6.2
13.7 Most sensitive
(15.2) position
∗ When the auto switch is ordered on its own, the auto switch mounting bracket is not enclosed.
In that case, please order it separately.
20
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Magnetic Field Resistant 2-Color Display
Solid State Auto Switch
D-P3DW/L/Z
(Electrical entry: Grommet)
It is possible to use in an
environment which generates
a magnetic field disturbance
(AC magnetic field).
A proper operating range can
be determined by the color of
the light.
(Red → Green ← Red)
For details about certified products
conforming to international standards,
visit us at www.smcworld.com.
Auto Switch Specifications
PLC: Programmable Logic Controller
D-P3DW/L/Z (With indicator light)
D-P3DW/L/ Z
Auto switch model
24 VDC relay, PLC
Applicable load
Load voltage
24 VDC (20 to 28 VDC)
Load current
6 to 40 mA
5 V or less
Internal voltage drop
1 mA or less at 24 VDC
Leakage current
40 ms or less
Operating time
Operating range······Red LED illuminates.
Proper operating range······Green LED illuminates.
Indicator light
CE marking, UL (CSA), RoHS
Standards
• Lead wire — Oilproof heavy-duty vinyl cable, ø4.8, 0.5 mm2, 2 cores,
D-P3DW: 0.5 m, D-P3DWL: 3 m, D-P3DWZ: 5 m
• Impact resistance — Switch: 1000 m/s2
• Insulation resistance — 50 MΩ or more at 500 VDC Mega (between lead wire and case)
• Withstand voltage — 1000 VAC for 1 minute (between lead wire and case)
• Ambient temperature — –10 to 60°C
• Enclosure — IEC60529 standard IP67
• Polarity: Non-polar
Caution
Precautions
Magnetic Field Resistance
If the current of the AC welding machine is 16000 A or lower, the auto switch can be used, even if the
distance between the welding conductor (gun cable) and the cylinder/actuator or auto switch is 0 mm.
Please contact SMC when the AC welding current exceeds 16000 A.
Weight
Auto Switch Internal Circuit
D-P3DW/L/Z
Unit: g
Auto switch model
D-P3DW/L/Z
Switch
main circuit
Lead wire length (m)
OUT (±) Brown
OUT (±) Blue
20
3
102
5
168
Dimensions
Body
Unit: mm
6
Indicator light
Indicator light/Display method
ø2.8 mounting hole
ON
3
Operating
range
500 (3000, 5000)
11
Red
3.2
Green
29
1
OFF
Display
Red
0.5
ø4.8
For single-phase AC welding machines
If it is used for current inverter welders
(including rectifying type) and condenser
type welders, the magnetic field resistance is
reduced. Please contact SMC regarding the
performance.
Proper operating range
Most sensitive
10.5 position
Auto switch mounting bracket
(For round groove mounting:
BQ3-032S)
4.7
Auto switch mounting bracket
(For square groove mounting:
BMG5-025S)
4.7
(29)
4
4
(29)
13.7 Most sensitive
(15.2) position
6.2
13.7 Most sensitive
(15.2) position
∗ When the auto switch is ordered on its own, the auto switch mounting bracket is not enclosed.
In that case, please order it separately.
21
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
VMG-D.qxd
10.3.29 5:27 PM
Page 1
ISO Standards [ISO/21287]
Compact Cylinder (ATEX directive category 2)
Series 55-C55
ø20,ø25,ø32,ø40,ø50,ø63,ø80,ø100
How to Order
55 C D 55 B 20 10
ATEX directive category 2
55
Rod end thread
Nil
M
Compliant with
ATEX directive category 2
Rod end female thread
Rod end male thread
Magnet
Cylinder stroke (mm)
None
Built-in magnet
Nil
D
Refer to page 2 for standard
and intermediate strokes.
Mounting style
B
L
F
G
C
Through-hole/Both ends
tapped common (Standard)
Foot style
Rod side flange style
Head side flange style
Single clevis style
Specifications
Type
Pneumatic (Non-lube)
Action
Double acting, Single rod
Fluid
Bore size
Air
Proof pressure
20 mm
20
25 mm
25
32 mm
32
40 mm
40
50 mm
50
63 mm
63
80 mm
80
100 100 mm
1.5 MPa
Maximum operating pressure
1.0 MPa
Minimum operating pressure
0.05 MPa (ø20 to ø63)
0.03 MPa (ø80, ø100)
Ambient and fluid temperature
Stroke length tolerance
Mounting
Piston speed
–10 to 60°C (No freezing)
Rubber bumper on both end
+1.0
0 mm
Through-hole/Both ends tapped common
Cushion
ø20 to ø63
50 to 500 mm/s
ø80, ø100
50 to 300 mm/s
Note) Stroke length tolerance dose not include the amount of bumper
change.
When using an Auto switch, select the appropriate switch from the following table and order it separately.
Applicable auto switch specifications
Auto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10°C ≤ Ta ≤ +60°C IP67)
For detailed specifications on the D-M9P(V), A93(V) and A90(V), please refer to page 16, 19.
(Note: Reed auto switches for 100 VAC and 100 VDC are not within the specification.
Solid state
switch
Model
D-M9PV첸-588
Reed switch
Type
D-A93V첸-588
D-M9P첸-588
Electrical entry
Grommet (Perpendicular)
Grommet (in-line)
D-M9PWV첸-588 Grommet (Perpendicular)
D-M9PW첸-588
D-A90V첸-588
D-A93첸-588
D-A90첸-588
Grommet (in-line)
Grommet (Perpendicular)
Grommet (in-line)
Load voltage
Indicator Wiring
light (output)
DC
AC
Yes
Yes
(2-color)
3-wire
(PNP)
Yes
No
Yes
No
2-wire
24 V
5V, 12 V
—
Lead wire length (m) ∗
0.5
3
5
(Nil)
(L)
(Z)
Applicable
load
IC circuit
24 V
12 V
—
—
24 V or less
48 V
48 V or less
—
IC circuit
24 V
12 V
—
—
24 V or less
48 V
48 V or less
—
IC circuit
Relay,
PLC
∗ Lead wire length symbols: 0.5 m ·········· Nil (Example) D-A93-588
∗ solid state auto switch is available after receiving an order.
3 m ·········· L (Example) D-A93L-588
5 m ·········· Z (Example) D-A93Z-588
Note) When mounting an auto switch on a 55-series (Category 2) model, the ATEX class of the cylinder with auto switch changes to Category 3, which is
the same class as the auto switch.
22
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Safety Instructions
Caution:
These safety instructions are intended to prevent hazardous situations and/or
equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC) ∗1),
and other safety regulations.
Caution indicates a hazard with a low level of risk
which, if not avoided, could result in minor or
moderate injury.
Warning:
Warning indicates a hazard with a medium level of
risk which, if not avoided, could result in death or
serious injury.
Danger :
Danger indicates a hazard with a high level of risk
which, if not avoided, will result in death or serious
injury.
Warning
1. The compatibility of the product is the responsibility of the
person who designs the equipment or decides its specifications.
Since the product specified here is used under various operating conditions, its
compatibility with specific equipment must be decided by the person who designs
the equipment or decides its specifications based on necessary analysis and test
results. The expected performance and safety assurance of the equipment will be
the responsibility of the person who has determined its compatibility with the
product. This person should also continuously review all specifications of the
product referring to its latest catalog information, with a view to giving due
consideration to any possibility of equipment failure when configuring the
equipment.
2. Only personnel with appropriate training should operate
machinery and equipment.
The product specified here may become unsafe if handled incorrectly. The
assembly, operation and maintenance of machines or equipment including our
products must be performed by an operator who is appropriately trained and
experienced.
3. Do not service or attempt to remove product and
machinery/equipment until safety is confirmed.
1. The inspection and maintenance of machinery/equipment should only be
performed after measures to prevent falling or runaway of the driven objects
have been confirmed.
2. When the product is to be removed, confirm that the safety measures as
mentioned above are implemented and the power from any appropriate source
is cut, and read and understand the specific product precautions of all relevant
products carefully.
3. Before machinery/equipment is restarted, take measures to prevent unexpected
operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety
measures if the product is to be used in any of the following
conditions.
1. Conditions and environments outside of the given specifications, or use outdoors
or in a place exposed to direct sunlight.
2. Installation on equipment in conjunction with atomic energy, railways, air
navigation, space, shipping, vehicles, military, medical treatment, combustion
and recreation, or equipment in contact with food and beverages, emergency
stop circuits, clutch and brake circuits in press applications, safety equipment or
other applications unsuitable for the standard specifications described in the
product catalog.
3. An application which could have negative effects on people, property, or animals
requiring special safety analysis.
4. Use in an interlock circuit, which requires the provision of double interlock for
possible failure by using a mechanical protective function, and periodical checks
to confirm proper operation.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
(Part 1: General requirements)
ISO 10218-1: Manipulating industrial robots - Safety.
etc.
Caution
1. The product is provided for use in manufacturing industries.
The product herein described is basically provided for peaceful use in
manufacturing industries.
If considering using the product in other industries, consult SMC beforehand and
exchange specifications or a contract if necessary.
If anything is unclear, contact your nearest sales branch.
Limited warranty and Disclaimer/
Compliance Requirements
The product used is subject to the following “Limited warranty and Disclaimer”
and “Compliance Requirements”.
Read and accept them before using the product.
Limited warranty and Disclaimer
1. The warranty period of the product is 1 year in service or 1.5 years after
the product is delivered.∗2)
Also, the product may have specified durability, running distance or
replacement parts. Please consult your nearest sales branch.
2. For any failure or damage reported within the warranty period which is clearly our
responsibility, a replacement product or necessary parts will be provided.
This limited warranty applies only to our product independently, and not to any
other damage incurred due to the failure of the product.
3. Prior to using SMC products, please read and understand the warranty terms
and disclaimers noted in the specified catalog for the particular products.
∗2) Vacuum pads are excluded from this 1 year warranty.
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
Also, even within the warranty period, the wear of a product due to the use of the vacuum pad
or failure due to the deterioration of rubber material are not covered by the limited warranty.
Compliance Requirements
1. The use of SMC products with production equipment for the manufacture of
weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
2. The exports of SMC products or technology from one country to another are
governed by the relevant security laws and regulations of the countries involved
in the transaction. Prior to the shipment of a SMC product to another country,
assure that all local rules governing that export are known and followed.
Record of changes
Edition B ∗ Bore sizes ø80, ø100 added.
NZ
Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.
Akihabara UDX 15F,
4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN
Phone: 03-5207-8249 Fax: 03-5298-5362
URL http://www.smcworld.com
© 2009 SMC Corporation All Rights Reserved
Specifications are subject to change without prior notice
D-G
1st printing JO printing NZ 6000SZ Printed in Japan.
and any obligation on the part of the manufacturer.
This catalog is printed on recycled paper with concern for the global environment.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Download PDF