Product Specifications 810008827/DB 810008827/DB    |       |    O

Product Specifications
810008827/DB | O-198
198--LA
LA--8W
8W--F12NS/25T
Single Jacket/Single Armor, Gel­Filled, Outdoor Stranded Loose Tube Cable l
Corrugated steel tape armor is strong yet flexible, providing additional crush and rodent protection Representative Image
General Specifications
Cable Type Stranded loose tube Construction Type Armored Subunit Type Gel­filled Construction Materials
Fiber Type Solution LightScope® ZWP®, zero water peak singlemode fiber (G.652.D, G.657.A1) Jacket Material PE Total Fiber Count 198 Armor Type Corrugated steel Fiber Type LightScope® ZWP®, zero water peak singlemode fiber (G.652.D, G.657.A1) Fiber Type, quantity 198 Fibers per Subunit, quantity 12 Jacket Color Black Jacket UV Resistance UV stabilized Dimensions
Buffer Tube/Subunit Diameter 2.50 mm | 0.10 in Cable Weight 153.0 lb/kft
Diameter Over Jacket 17.20 mm
Filler, quantity 1 Subunit, quantity 17 |
|
228.0 kg/km 0.68 in Physical Specifications
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 1 of 3
April 14, 2016
Product Specifications
810008827/DB | O
810008827/DB | O--198
198--LA
LA--8W
8W--F12NS/25T
Minimum Bend Radius, loaded 25.7 cm
Minimum Bend Radius, unloaded 17.2 cm | 6.8 in |
Tensile Load, long term, maximum 180 lbf
|
Tensile Load, short term, maximum 2700 N
|
Vertical Rise, maximum 10.1 in 800 N 607 lbf 1176.0 ft
|
358.0 m Environmental Specifications
Environmental Space Aerial, lashed
|
Buried Installation Temperature ­30 °C to +70 °C (­22 °F to +158 °F) Operating Temperature ­40 °C to +70 °C (­40 °F to +158 °F) Storage Temperature ­40 °C to +75 °C (­40 °F to +167 °F) Mechanical Test Specifications
Compression 250 lb/in | 44 N/mm Compression Test Method FOTP­41
Flex 35 cycles Flex Test Method FOTP­104
Impact 4.34 ft lb
|
5.88 N­m Impact Test Method FOTP­25
|
IEC 60794­1 E4 Strain See long and short term tensile loads Strain Test Method FOTP­33
Twist 10 cycles Twist Test Method FOTP­85
Water Penentration 24 h Water Penentration Test Method FOTP­82
|
IEC 60794­1 E3 |
IEC 60794­1 E6 |
IEC 60794­1 E1 |
IEC 60794­1 E7 |
IEC 60794­1 F5 Environmental Test Specifications
Cable Freeze ­2 °C
Cable Freeze Test Method FOTP­98
|
28 °F Drip 70 °C
Drip Test Method FOTP­81
Heat Age ­40 °C to +85 °C (­40 °F to +185 °F) Heat Age Test Method IEC 60794­1 F9 Low High Bend ­30 °C to +60 °C (­22 °F to +140 °F) Low High Bend Test Method FOTP­37
Temperature Cycle ­40 °C to +70 °C (­40 °F to +158 °F) Temperature Cycle Test Method FOTP­3
|
|
IEC 60794­1 F15 158 °F |
|
|
IEC 60794­1 E14 IEC 60794­1 E11 IEC 60794­1 F1 Qualification Specifications
Cable Qualification Standards ANSI/ICEA S­87­640
|
EN 187105
|
Telcordia GR­20 Regulatory Compliance/Certifications
Agency
RoHS 2011/65/EU
ISO 9001:2008
Classification
Compliant
Designed, manufactured and/or distributed under this quality management system
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 2 of 3
April 14, 2016
Product Specifications
810008827/DB | O
810008827/DB | O--198
198--LA
LA--8W
8W--F12NS/25T
Included Products
DB­8W­LT (Product Component—not orderable) — LightScope ZWP® Singlemode Fiber ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 3 of 3
April 14, 2016
Download PDF