Valve position A1 indicator for BHH/BHHF actuators

Valve position A1 indicator for BHH/BHHF actuators
Data sheet
VPI-01
Sheet No.: VPI01.01 RevA
Date: October 2010
Valve position A1 indicator for BHH/BHHF actuators
Versions:
The VPI indicator is available in 3 versions
VPI-V: Visual indication
VPI-E: Visual + electrical open/closed indication (switches)
VPI-C: Visual + electrical analog (potentiometer) indiction
Hydraulic data:
Max. working pressure:
Test pressure:
Burst pressure:
Temperature range:
Viscosity range:
Filtration requirement:
Hydraulic medium:
Max. flow:
Min. flow:
Connection face:
Insulation class:
135 bar (1958 PSi)
205 bar (2973 PSi)
> 525 bar (7615 PSi)
-20° C to 80° C (-4° F to 176° F)
15-200cSt
25 μm nominal
Acid-free hydraulic oil
100 cm/sec (6 l/min)
3 cm/sec (0.3 l/min)
DIN 24 340 Cetop-3/ VPI connection
IP 44/IP 67-on request
General Description:
Basically the valve position indicator is a precision gear motor with a display indicating
the flow of a certain oil volume through the unit.
The gear wheels rotate according to flow and flow direction of the fluid. A built-in mini gear
box with a gear ratio chosen to suit the displacement in question transfers the gear motor
movement to the indicator shaft. There is no mechanical connection between the gear motor
and the indicator shaft. The rotary movement of the hydraulic gear wheels is transferred to
the indicator shaft by a magnetic clutch. This eliminates possible external leakage.
An indicator arrow moves within a scale angle which is adjustable between 75° and
200°. A small indicator disc (flow indication) mounted firmly on the indicator shaft serves
as leakage indicator.
Materials:
Housing, top cover and bottom member:
Screws, sign plates and rivets:
Seals and friction elements:
Sight glass:
Weight:
Note:
ALMgSi 1.0 Anodized
AISI 304, quality 8.8 (on screws 12.9)
NBR ~ Acrylonitrile Butadiene
PMMA
Approx. 1.2 kg (2.7 lb)
Hydraulic position indicators in brass/
stainless steel on request.
Operating restrictions:
Flushing of control lines must never take place through the VPI.
www.Bettis.com
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center.
USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600
Data sheet
VPI-01
Sheet No.: VPI01.02 RevA
Date: October 2010
Main dimensions:
(1.81)
(2.03)
(1.98)
(5.98)
(1.08)
(.23) (.91)
(2.83)
(1.32) (.031)
(1.95)
Main layout:
(1.95)
Note:
The top (indicator) part of the VPI can be mounted in
any of 4 possible positions in relation to the main body/
mainfold.
(1.18)
(1.95)
(1.18)
Hydraulic symbol:
Connection plug
Visual indication
Top part containing
electrical parts
Gear box
Housing with CETOP
3 mounting surface
VPI-V
VPI-E
Magnetic clutch
Bottom part with gear
motor
VPI-C
Choice of gear box:
Measuring range for VPI-TC:
-Actuator displacement + compression of oil (1-1.5% of pipe volume).
Measuring range for VPI-PTC:
-Actuator displacement.
Pipe
size
mm
Ø6
Ø7
Ø8
Ø9
Ø10
www.Bettis.com
Pipe volume
each 10 metres
cm³
in³
282.7
17.6
384.8
23.5
506.6
30.9
636.0
38.8
785.0
47.9
Compression volume
each 10 metres
cm³
in³
4.24
0.26
5.77
0.35
7.54
0.46
9.54
0.58
11.78
0.72
Measuring range
from
15
25
40
70
100
170
260
430
700
1250
2200
3500
5600
cm³
up to
25
40
70
100
170
260
430
700
1250
2200
3500
5600
11000
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center.
USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600
from
0.9
1.5
2.4
4.3
6.1
10.4
15.9
26.2
42.7
76.3
134.2
213.5
341.6
in³
Gear
up to
1.5
2.4
4.3
6.1
10.4
15.9
26.2
42.7
76.3
134.2
213.2
341.6
671.0
Ratio 1:
0015
0025
0040
0060
0100
0150
0250
0405
0720
1280
2000
3125
6103
Data sheet
VPI-01
Sheet No.: VPI01.03 RevA
Date: October 2010
Application:
The VPI is designed to indicate the position of hydraulically actuated valves and the indicator arrow in the display will move from
fully open to fully closed or vice versa when a volume equal to the actuator displacement passes through the unit. Observe the
min. and max. flows when dimensioning a hydraulic system including VPI indicators. Also observe the various factors influencing
the accuracy and reliability of this indirect position indication method.
Typical application:
VPI combinations on manifold:
VPI-V:
This indicator is only used for visual indication of the valve position. It is normally used with TC-block and manual pilot valve.
VPI-V can be used with PTC-block.
VPI-E:
This indicator is used for visual and electric (ON/OFF) indication of the end positions of the valve (open/ closed). The VPI-E is
normally used with TC-block, but VPI-E can also be used with PTC-block. VPI-E is available with “normally open” switches, but
can as a variant be supplied with “normally closed” switches.
VPI-C:
This indicator is used for visual and continuous indication with analog electric signal (potentiometer). This type is used wherever
electric indication of the intermediate position of the valve is required. VPI-C is normally used with PTC-block.
www.Bettis.com
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center.
USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600
Data sheet
VPI-01
Sheet No.: VPI01.04 RevA
Date: October 2010
Terminal layout:
VPI-C
Terminal layout:
External wiring
Hook-up:
Signal processing:
Manufacturer’s data of micro switches:
Contact material
Gold alloy X-point
Operating force
(g max) 90 g
Electrical rating
100mA 125 VAC
Life expectancy 3 x106
Electrical rating 100 mA 30 VDC
Life expectancy 3 x 106
Max. temp. 85°C (185°F)
Manufacturer’s data of potentiometers:
General specifications:
For transforming the resistance signal into
a standard 4 - 20 mA signal we recommend Standard resistance values
Total resistance tolerance
the DSH Isolation Amplifier 2204.
2KΩ
+ 10%
Independent linearity tolerance
Resolution output smoothness
< 0.1%
Insulation resistance
Hook-up:
+ 1.0%
essentially infinite
> 1.000MΩ at 500V.D.C.
Dielectric strength
1 min. at 500V.D.C.
Resistance temp. coefficient
+ 400 ppm/° C
Environmental performances
User data:
Max. continuous load: 0.2 W (VA)
Max. peak load: 1 W (VA)
The normal approx. output range is 300Ω
in closed position and between 850Ω and
1700Ω in open position.
The open position signal is dependent on
the choice of gear box size.
Operating temp. range
-55° C to +105° C
(-67° F to +221° F)
Temp. cycle
5 cycles below-55° C. to +105° C
(-67° F to +221° F)
Total resist. value var. < +10%
Vibration Shock
50G 11mS
Total resist. value var. < +1%
Moisture Resistance
10Hz to 2,000Hz 15G.
Total resist. value var. < +2%
40° C 95% RH 120 hours
total resist. value var. < +10%
Insulation resistance > 10MΩ
Connection plug data:
Cable outer diam. : 6-15 mm (0.24 - 0.59 in)
Thread : PG 11
Note: Not Certified dimensional drawings. Such drawings are available on request. Contact factory with correct model designation and serial number.
Important: Due to Emerson’s continuing commitment to engineered product advancement, data presented herin is subject to change.
The contents of the publication are presented for information purposes only, and while effort has been made to ensure their accuracy,
they are not to be construed as warranties or guarantees, expresses or implied, regarding the products or services described herein or their use or applicability.
All sales are governed by our terms and conditions, which are available on request.
We reserve the right to modify or improve the designs or specifications of our products at any time without notice.
www.Bettis.com
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center.
USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement