Gas Stationary Horizontal Mixer Kettles

Project ________________________________
™
Cleveland
Item __________________________________
Quantity _______________________________
FCSI Section ____________________________
COOK CHILL SYSTEMS
Approval _______________________________
Cook/Chill Systems
COOK/CHILL GAS
HORIZONTAL AGITATOR
STATIONARY MIXER KETTLES
MODELS:
Date __________________________________
HA-MKGL-60-CC
HA-MKGL-80-CC
HA-MKGL-100-CC
Cleveland Standard Features
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Full 60, 80 or 100 gallon working capacity
Type 316 stainless steel for all food contact surfaces
Precise solid state temperature control
Solid state low water safety controls in a plug-in module
L.E.D. indicators for heat cycle and low water warning
3" diameter air operated flush mounted piston draw-off valve
with variable control (requires air compressor)
Flush mounted, easily removable temperature probe
Spring assisted, hinged stainless steel cover
Three (3) horse power horizontal agitator drive
Variable mixer speed control from 5 to 20 r.p.m. with
agitator start/stop controls
Spring loaded teflon blades scrape the entire heated
surface area
Internal mixing fins for efficient, uniform mixing of products
Easily removable agitator without the use of tools
190 M-BTU high efficiency power burner heating system
for fast heat-up and recovery times
"Glow type" automatic safety ignition system
Kettle steam jacket permanently filled with treated distilled water
50 psi steam jacket rating and safety valve
Front mounted combination pressure-vacuum gauge
Heavy duty welded rim bar
Hot and cold water kettle filler with swing spout
Standard for Natural Gas operation
Standard Electrical for agitator drive is 208V/3Ph/60Hz
AGA, CGA, NSF approved
Accepted for use in USDA inspected facilities
Note: This COOK-CHILL Mixer Kettle requires a control panel
for operation which must be specified separately
Standard Features for for remote mounted Cook-Chill Kettle Control Panel:
I Precise, consistent temperature control with digital read-out
I Time/Temperature chart recorder to provide permanent
record of batch production
I Automatic water meter for cold water
I Automatic and manual heating control
I Built to U.L. specifications
Options & Accessories
Ë Dual remote cook-chill kettle control panel for operating two
HA mixer kettles
Short Form Specifications
Shall be CLEVELAND Model HA-MKGL- ____ -CC, gas fired,
____ gallon operating capacity, COOK/CHILL, stationary
horizontal agitator mixer kettle,190M BTU High Efficiency Power
Burner heating system, type 316 Stainless Steel for all food
contact surfaces, 50 psi jacket rating, Spring Assist Cover, 3HP
Motor Drive for mixer arm with variable speed control, 3" Air
Operated Piston Draw-off Valve, Flush Mounted Temperature
Probe, Automatic Water Meter for cold water.
NOTE: Specify remote or kettle mounted cook/chill control panel.
Ë Kettle mounted control center with time/temperature chart
recorder
Ë Dolly for horizontal agitator
Ë Stainless steel bi-fold hinged cover
Ë Electric chain hoist for loading products
Ë Kettle Accessory Kit (KAK) includes:
Ë Clean-up Brush (CB)
Ë 36" Kettle Whip (KW)
Ë Draw-off Brush (DB)
Ë 36" Kettle Paddle (KP)
Ë 36" Kettle Brush (KB)
Ë 24 oz. Ladle (KL)
Ë Option for propane gas operation (PG)
Ë Voltage option for agitator drive other
than standard 208V/3Ph/60Hz
Ë 3", 90° Elbow
1333 East 179 St.,
Tel: 1-216-481-4900
Web Site: www.ClevelandRange.com
Cleveland, Ohio, U.S.A. 44110
Fax: 1-216-481-3782
Email: Steam@ClevelandRange.com
SECT.
XIV
3
PAGE
0609
5/8"ø,
MOUNTING
HOLES ON
UNDERSIDE
OF PANEL
1 1/2"
10 1/2"
10 1/2"
1 1/2"
12"
13"
13"
1 1/2"
9 1/4"
ELECTRICAL
SUPPLY
VOLTS: 208/240
PHASE: 3
BTU PER CU. FT.:
15
1000 (NAT), 2500 (LP)
FREQ:
60 HZ
SUPPLY PRESSURE:
APPROVALS
CGA
H C HOT & COLD
WATER
4" to 14" W.C.
NSF
APPROX.
SHIPPING
WEIGHTS
PRESSURE:
NOTE: Air must be dry,
clean and free of oil.
90 - 100 PSI
FLOW RATE:
1/2 cfm (for piston draw-off valve)
25 cfm (for food pump operation)
TYPE: NAT or LP
AMPS:
AGA
A AIR SUPPLY (PIPING 1/2" NPT)
GAS SUPPLY
(PIPING 3/4" NPT)
BTU RATINGS:
3/4" NPT CONNECTION
190,000 per hour
40-60 PSI PRESSURE
15"
24"
40"
60 GAL 980 LBS.
446 KG.
80 GAL 1070 LBS.
487 KG.
100 GAL 1150 LBS.
523 KG.
CLEARANCE
RIGHT: 3", LEFT: 12"
REAR: 3"
(ALLOW 12" SPACE
MINIMUM ON LEFT
SIDE FOR SERVICE)
69"
NOTE: This Cook-Chill Mixer Kettle requires a control panel for operation which must be specified separately
MINIMUM CLEARANCE
FRONT: 36", SIDES: 12", REAR: 0"
APPROX. SHIPPING WEIGHT
650 LBS., 296 KG.
L
M
3" REF.
K
M
REMOTE CONTROL PANELS
FLOOR MOUNT MODEL
(HA-SG-CC & HA-DG-CC )
WALL
10 3/8
H C
Q
REMOTE OR KETTLE MOUNTED
CONTROL FEATURES
18 5/8
• TEMPERATURE CONTROL WITH DIGITAL
READ OUT
• TIME/TEMPERATURE CHART RECORDER
• AUTOMATIC WATER METER FOR COLD
WATER ONLY
C
G
CHART
RECORDER
BOX
F
CL
P
RECOMMENDED
FLOOR DRAIN
SPRING ASSIST
COVER (FULLY
OPEN AT 90°)
OPTIONAL KETTLE MOUNTED
CONTROL PANEL WITH CHART RECORDER
C
A I.D.
D
RIM BAR
WATER
METER
3 HP
ELECTRIC
MOTOR
WALL
P
N
H
C
67"
12" X 24"
E
(COVER
FULLY
OPEN)
5 1/2"
H C
2"
5/8"Ø,
2 HOLES
ON
4" B.C.D.
3/8"
B
1" (MAX. ADJUSTMENT)
SOLID
FOOT DETAIL
A
RECOMMENDED FLOOR
SLOPE 1 INCH PER 4 FEET
6" RECOMMENDED
8 3/4"
13 5/8"
4"
FLOOR DRAIN
FLUSH MOUNTED
TEMPERATURESENSOR
3" AIR VALVE
(FPVA-3)
3" MIN
CLEARANCE
PIPE DRAIN RECOMMENDED
MINIMUM VALVE SIZE PLUS 1"
DIMENSIONS
MODEL
HA-MKGL-60-CC
HA-MKGL-80-CC
HA-MKGL-100-CC
A
29 1/2"
33"
35 1/2"
B
48 1/4"
51 3/4"
54 1/4"
C
50"
58"
60 1/2"
D
36 1/2"
39"
40 3/4"
E
83"
90"
96"
F
13 1/8"
14 7/8"
16 1/8"
G
34 5/8"
35 15/16"
37 1/8"
K
23 7/8"
24 5/8"
25 1/4"
L
19 1/8"
20 7/8"
22 1/8"
M
10 3/32"
11 17/32"
12 3/4"
N
24"
26"
27 1/4"
Q
17 7/8"
18 5/8"
19 1/4"
P
9 3/4"
9 3/4"
11"
NOTES: Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are: UL, A.G.A., NSF, ASME/N.BD., CSA, CGA, ETL, and others.
Installations of back flow preventers, vacuum breakers and other specific code requirements are the responsibility of the owner and installer.
All vertical dimensions shown are minimum.Feet are adjustable to +1" maximum.
Manufacturer must be notified if unit will be operating above 2000' altitude.
Consult factory for manufactured gas.
Cleveland Range reserves right of design improvement or modification, as warranted.
XIV
4
(NOT TO SCALE)
SECT.
PAGE
0609
Litho in USA