Pass-Thru
Hot Cabinet
Rev. 7 (7/08)
FL-2254
Page 1 of 5
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137PUA...C/H138P1834C and H137PSUA...C/H138PS1834C
Pass-Thru Series Hot Cabinets
ELECTRICAL SPECIFICATIONS:
Model No.
H137PSUA12C
H137PUA12C
H137PSUA9C
H137PUA9C
H137PSUA6C
H137PUA6C
H138PS1834C
H138P1834C
H137PSUA12C208
H137PUA12C208
H137PSUA9C208
H137PUA9C208
H137PSUA6C208
H137PUA6C208
H138PS1834C208
H138P1834C208
H137PSUA12C240
H137PUA12C240
H137PSUA9C240
H137PUA9C240
H137PSUA6C240
H137PUA6C240
H138PS1834C240
H138P1834C240
Volts
120
208
240
Watts
2000
2000
2000
Amps
16.7
10.0
8.6
Hertz
60
60
60
Phase
1
1
1
NEMA
5-20P
6-15P
6-15P
Note: The above model numbers are basic models. They may be followed by letters: L, M, 2M, D or ending with S and/or Z
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
REPAIR SHOULD BE DONE BY AUTHORIZED SERVICE
PERSONNEL ONLY
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Pass-Thru
Hot Cabinet
Rev. 7 (7/08)
FL-2254
Page 2 of 5
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137PUA...C/H138P1834C and H137PSUA...C/H138PS1834C
Pass-Thru Series Hot Cabinets
HOW TO INSTALL UNIT:
1. Place cabinet on level fl oor.
2. Plug cord into proper wall outlet.
Yellow Light
Power Switch
Thermostat Thermometer
HOW TO START UNIT:
1. Push POWER switch to ON. The yellow light will turn on.
2. Turn thermostat knob to #7.
3. Preheat cabinet for 60 minutes.
4. Put food into cabinet.
5. Turn thermostat to #8 and close door.
No. 8 setting = approx. 185°F/85°C
No. 6 setting = approx. 160°/71°C
No. 4 setting = approx. 130°/54°C
Note: The optional digital thermometer display fl ashes when center of cabinet is below 140°F
(60°C) or above 250°F (121°C). Call the factory if you need different settings.
NOTE: Proper food holding temperature is
140°F/60°C or higher.
TO TURN OFF UNIT:
Push the POWER switch to OFF.
The yellow light will go out.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Pass-Thru
Hot Cabinet
Rev. 7 (7/08)
FL-2254
Page 3 of 5
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137PUA...C/H138P1834C and H137PSUA...C/H138PS1834C
Pass-Thru Series Hot Cabinets
WARNING
BEFORE Cleaning the Cabinet:
1. Allow cabinet to cool.
2. Do NOT use abrasives or harsh chemicals.
Cleaning Notes:
1. Wipe up spills as soon as possible.
2. Clean cabinet regularly to avoid heavy dirt build-up.
3. Make a test spot with cleaner.
4. Follow manufacturer’s directions on cleaner.
5. Do not mix cleaners.
6. Avoid drips and splashes.
Is your cabinet of aluminum or stainless steel construction?
Be sure your cleaner is suitable for that material.
NOTE: Stainless steel cabinets have “S” in the model number.
SOIL
DIRT
FINGERPRINTS,
GREASE and OIL
WATER SPOTS
HOW TO CLEAN UNIT:
CLEANER
Mild detergent* and hot water, or mild abrasive cleaner.
Steam (no strong alkaline additive).
Chemical oven cleaner.
METHOD
1. Use soft, damp cloth.
2. Rinse with hot water
3. Wipe dry.
1. Rinse after steam cleaning.
2. Wipe dry.
Follow oven cleaner manufacturer’s directions
Mild abrasive cleaner; oily or waxy cleaner.
Apply with a soft, clean cloth.
Mild abrasive cleaner.
1. Apply with damp cloth.
2. Rinse and dry.
*Mild detergents include soaps and non-abrasive cleaners.
Note: Gaskets are removable for cleaning.
TROUBLE-SHOOTING CHART:
FAILURE:
1. Yellow light on switch does NOT light.
2. Unit does not heat.
3. Unit gets too hot or won’t shut off.
POSSIBLE CAUSE:
1a. Circuit breaker/fuse to wall outlet is blown
1b. Cord is unplugged from wall outlet.
1c. Switch is “OFF.”
2a. Thermostat set too low or is “OFF.”
2b. Switch is “OFF.”
3a. Defective electrical parts.
UNPLUG UNIT FROM WALL OUTLET.
4. Blower does not work or makes noise.
4a. Defective blower
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Pass-Thru
Hot Cabinet
Rev. 7 (7/08)
FL-2254
Page 4 of 5
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137PUA...C/H138P1834C and H137PSUA...C/H138PS1834C
Pass-Thru Series Hot Cabinets
REPLACEMENT PARTS
DESCRIPTION
Power Unit
Heater kit, air
2000w
120 Volt
0675-004
2000w + digital therm 0675-004-D
-2000w
(2-1000w)
0811-074
0848-060
208 Volt
0675-005
0675-005-D
240 Volt
0675-005
0675-005-D
0811-074-01
High Limit 0848-060 0848-060
Thermometer
Transformer (used with digital thermometer) 0769-159
Thermostat, air -analog 0848-062-K
Power Cord
-analog
-digital
-solid state
5238-030
5238-034
0848-008-ACK
0810-065-10
5238-030
5238-034
0769-159
0848-062-K
0848-008-ACK
0810-039-02
5238-030
5238-034
0769-159
0848-062-K
0848-008-ACK
0810-039-02
Power Switch
Power Light
Vent fan
0808-116
0766-094
0769-165
0808-116
0766-095
0769-174
0808-116
0766-095
0769-174
0769-182-K Blower Kit
Door, complete -aluminum
-aluminum
Door, gasket
Door, hinge
-stainless steel
-stainless steel
-aluminum
-aluminum
-stainless steel
-stainless steel
-aluminum
-stainless steel
0769-180-K 0769-182-K
UA12/UA6/1834 1221-524
UA9 1221-527
UA12/UA6/1834 1221-525
UA9 1221-526
UA12/UA6/1834 0861-235
UA9 0861-236
UA12/UA6/1834 0861-185
UA9 0861-182
0519-087-K
0519-074-K
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Pass-Thru
Hot Cabinet
Rev. 7 (7/08)
FL-2254
Page 5 of 5
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137PUA...C/H138P1834C and H137PSUA...C/H138PS1834C
Pass-Thru Series Hot Cabinets
TERMINAL BL
TRANSFORMER 110V/220V
POWER SWIT
5-20P 120V
TRANSFORMER 110V/220V
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com