Prewire diagram

Prewire for Model 305-S12, 400-S12, 410-S12
Prewire for all “Pan”, “TES2”, ‘’Vik”, “Elan”, etc.
Holovision Face Plate
Holovision Rough-in Box
From Main
Equipment
Area
Cat 5/6 (communication)
16/18 gauge - 2 conductor for keypad
2 conductors (22/2 or spare pair from Cat 5)
For gate release from phone system*
Exit button (REX)
To gate
NOTE:
Wires shown in red are the minimum required
Wires shown in blue are optional
Note on Essex Wiring: Electric motorized gates require only a contact closure from the S12
keypad. Electric strikes or mag locks can draw several amps, and the appropriate wire size
should be calculated. Longer runs will require a heavier gauge wire.
Note: If the power supply shipped with the S12 (12 VDC) is used to activate the strike, the strike
will relieve 12 VDC. If AC is required for the strike, a separate pair of wires should be supplied.
Wire for gate release from phone system is required, but it can ben be a spare pair from Cat5/6
Page 1
This document is property of Holovision, and may not be reproduced without permission.
2.1 IC and 2x6
Prewire for Model 305-A, 305-W, 400-A, 400-W,
410-A, 410-W
Prewire for all “Pan”, “TES2”, ‘’Vik”, “Elan”, etc.
Holovision Face Plate
Holovision Rough-in Box
From Main
Equipment
Area
Wiegand
or
ASCII
Controller
Cat 5/6 (communication)
Keypad cable (see note below)
2 conductors (22/2 or spare pair from Cat 5)
For gate release button
2 conductors 16-18 gauge for electric strike
Exit button (REX)
NOTE:
Wires shown in red are the minimum required
To gate
Wires shown in blue are optional
Wiegand Keypads:
Cable Distance
Wiegand or Clock-and-Data interface: 500 feet
Recommended cable
Alpha 1295, Belden 5503FE 5 conductor, 22 AWG stranded with overall shield
or equivalent
ASCII Keypads:
Cable Distance
ASCII controller: 500 feet
Recommended cable
Cat 5, Cat 6
Page 2
This document is property of Holovision, and may not be reproduced without permission.
2.1 IC and 2x6
Prewire for Model 305-S12, 400-S12, 410-S12
Prewire for VIO2
Holovision Face Plate
Holovision Rough-in Box
From Main
Equipment
Area
Cat 5/6 (communication)
Cat 5/6 (spare)
VIO2
18/4 or 16/4 miscellaneous
To gate
Exit button (REX)
NOTE:
Wires shown in red are the minimum required
Wires shown in blue are optional
Note: If VIO2 is used to activate the strike, the strike will relieve 12 VDC. If AC is required for
the strike, a separate pair of wires should be supplied.
Page 3
This document is property of Holovision, and may not be reproduced without permission.
2.1 IC and 2x6
Prewire for Model 305-A, 305-W, 400-A, 400-W,
410-A, 410-W
Prewire for VIO2
Holovision Face Plate
Holovision Rough-in Box
From Main
Equipment
Area
Wiegand
or
ASCII
Controller
Cat 5/6 (communication)
Cat 5/6 (spare)
VIO2
Keypad cable (see note below)
2 conductors 22 gauge for release button
2 conductors 16-18 gauge for electric strike
Exit button (REX)
NOTE:
Wires shown in red are the minimum required
To gate
Wires shown in blue are optional
Wiegand Keypads:
Cable Distance
Wiegand or Clock-and-Data interface: 500 feet
Recommended cable
Alpha 1295, Belden 5503FE 5 conductor, 22 AWG stranded with overall shield
or equivalent
ASCII Keypads:
Cable Distance
ASCII controller: 500 feet
Recommended cable
Cat 5, Cat 6
Page 4
This document is property of Holovision, and may not be reproduced without permission.
2.1 IC and 2x6
Door Station Rough-in
Model 305, 400, 410
50”
NOTE: All dimensions
given are relative to
“finished” surface, not
rough grade.
Page 5
This document is property of Holovision, and may not be reproduced without permission.
2.1 IC and 2x6
Installation Details - 300 and 600 Series
1 3/4” reveal at top of
box (beyond surface
of finished masonry)
58” to top of box
Finished elevation
Installation on smooth wall
1 3/4” reveal at top of
box (beyond surface
of finished masonry)
58” to top of box
Finished elevation
Installation on stone wall
Page 6
This document is property of Holovision, and may not be reproduced without permission.
2.1 IC and 2x6
Installation Details - 2 Piece Gooseneck
OPTION -conduit to
gate. See second
page for more details
Center of Rough-in template
is 19” from edge of the curb
(This will allow 1/2 of the
intercom box to overhang)
48” to center
Gooseneck
Rough-in Template
2” to top of rough-in template
from surface of driveway
(this will place center of
intercom box at 48”)
Ground level
Surface of finished driveway
Conduit to gate
Conduit to house
ROUGH-IN BRACKET INSTALLATION
Hand hole in pole
Ground level
Conduit to gate
(optional)
Use 3 or 4 bags of
ready mix cement
Conduit to house
NOTE: PVC elbows must be facing
in proper direction to minimize 900
bends in conduit to gooseneck
DETAIL OF ATTACHMENT OF POLE ONTO BASE
Page 7
This document is property of Holovision, and may not be reproduced without permission.
2.1 IC and 2x6
Installation Details - 2 Piece Gooseneck
Optional application with 2 conduits
2” Steel
Gooseneck Pole
Cover for
access door
NOTE: BE SURE THAT CONDUITS ARE
SECURED BEFORE POURING CONCRETE.
LARGE CONDUIT MUST BE PLUMB IN
ORDER TO FIT INSIDE 2” GOOSENECK
MOUNTING POLE
3/4” LB shown with
male adapter, close
nipple and lock nut
(all of these parts
are by others)
1 1/4”
sweep 90 deg
elbow (by Holovision)
DO NOT GLUE
MALE ADAPTER
TO PVC PIPE!!
Ground level
1 1/4”
3/4” conduit to gate
motor (elbow and
conduit by others)
Stainless Steel
Mounting Bolts (4)
x
1”
reducer (by others)
1” (minimum)
conduit to house
NOTE: BE SURE BOTH CONDUITS ARE POINTED IN
THE DIRECTION THAT WILL MINIMIZE THE USE OF
ELBOWS!
Page 8
This document is property of Holovision, and may not be reproduced without permission.
2.1 IC and 2x6
Download PDF