Batteries Rechargeable Batteries NiMH Batteries (Nickel Metal Hydride) NiMH Series HHR200A Data sheet

Batteries Rechargeable Batteries NiMH Batteries (Nickel Metal Hydride) NiMH Series HHR200A Data sheet
NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET
Typical Charge Characteristics
HHR200A Cylindrical 4/5A size (HR 17/43)
Dimensions (with Tube)
(mm)
2.0
Charge: 1700mA(0.85 It)✕1.4hrs.
1.9
Voltage (V)
1.8
17.0 +- 00.7
1.7
1.6
1.5
1.4
1.3
1.2
1.1
(+)
0˚C
20˚C
40˚C
1.0
0.9
0.8
0
10
20
30
40 50 60 70 80
Charge Time (minutes)
90
100 110 120
43.0 +- 01.5
Typical Discharge Characteristics
1.8
Charge: 1700mA(1 It)✕1.2hrs,20˚C
Discharge Temperature: 20˚C
1.7
Voltage (V)
1.6
( )
1.5
1.4
1.3
1.2
1.1
Specifications
1.0
mm
inch
0.9
Diameter
17.0+0/-0.7
0.67+0/-0.03
0.8
0
Height
43.0+0/-1.5
1.69+0/-0.06
Approximate
Weight
Grams
Ounces
32
1.13
Nominal Voltage
Discharge
Capacity*
1.2V
1.8
Average**
2040 mAh
1.7
Rated (Min.)
2000 mAh
2
3
4
Discharge Time (hours)
5
6
Charge: 1700mA(0.85 It)✕1.4hrs,20˚C
Discharge Temperature: 20˚C
Charge
Charge
20mΩ
Standard
200mA (0.1It) x 16hrs.
Rapid
2000mA (1It) x 1.2 hrs.
Standard
Rapid
Discharge
Storage
Voltage (V)
1.6
Approx. Internal impedance
at 1000Hz at charged state.
Ambient
Temperature
400mA(0.2 It)
1
< 1 year
< 3 months
< 1 month
1.5
1.4
1.3
1.2
1.1
1.0
˚F
0.9
0˚C to 45˚C
0˚C to 40˚C
-10˚C to 65˚C
-20˚C to 35˚C
-20˚C to 45˚C
32˚F to 113˚F
32˚F to 104˚F
14˚F to 149˚F
-4˚F to 95˚F
-4˚F to 113˚F
0.8
0
-20˚C to 55˚C
-4˚F to 131˚F
˚C
2000mA(1 It)
4000mA(2 It)
10
20
30
40
50
60
70
Discharge Time (minutes)
80
90
100
* After charging at 0.1It for 16 hours, discharging at 0.2It.
** For reference only.
Battery performance and cycle life are strongly affected by how they
are used. In order to maximize battery safety, please consult Panasonic
when determining charge / discharge specs, warning label contents
and unit design.
Note:
[It] was previously expressed as [C]. [It] is an IEC standard expression
for the amount of charge or discharge current and is expressed as:
It(A) = Cn (Ah)/1h.
• [It] is the reference test current in ampres
• [Cn] is the rated capacity of the cell or battery in Ampere-hours.
n = the time base [hours] for which the rated capacity is declared
NICKEL METAL HYDRIDE HANDBOOK
AUGUST 2005
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to
modification without notice. Contact Panasonic for the latest information.