Lecroy WAVERUNNER 64MXI

Add to my manuals
25 Pages

advertisement

Lecroy WAVERUNNER 64MXI | Manualzz

Test Equipment Solutions Datasheet

Test Equipment Solutions Ltd specialise in the second user sale, rental and distribution of quality test & measurement (T&M) equipment. We stock all major equipment types such as spectrum analyzers, signal generators, oscilloscopes, power meters, logic analysers etc from all the major suppliers such as Agilent, Tektronix, Anritsu and Rohde & Schwarz.

We are focused at the professional end of the marketplace, primarily working with customers for whom high performance, quality and service are key, whilst realising the cost savings that second user equipment offers. As such, we fully test & refurbish equipment in our in-house, traceable Lab. Items are supplied with manuals, accessories and typically a full no-quibble 2 year warranty. Our staff have extensive backgrounds in T&M, totalling over 150 years of combined experience, which enables us to deliver industry-leading service and support. We endeavour to be customer focused in every way right down to the detail, such as offering free delivery on sales, covering the cost of warranty returns BOTH ways (plus supplying a loan unit, if available) and supplying a free business tool with every order.

As well as the headline benefit of cost saving, second user offers shorter lead times, higher reliability and multivendor solutions. Rental, of course, is ideal for shorter term needs and offers fast delivery, flexibility, try-before-you-buy, zero capital expenditure, lower risk and off balance sheet accounting. Both second user and rental improve the key business measure of

Return On Capital Employed.

We are based near Heathrow Airport in the UK from where we supply test equipment worldwide. Our facility incorporates Sales, Support, Admin, Logistics and our own in-house

Lab.

All products supplied by Test Equipment Solutions include:

- No-quibble parts & labour warranty (we provide transport for UK mainland addresses).

- Free loan equipment during warranty repair, if available.

- Full electrical, mechanical and safety refurbishment in our in-house Lab.

- Certificate of Conformance (calibration available on request).

- Manuals and accessories required for normal operation.

- Free insured delivery to your UK mainland address (sales).

- Support from our team of seasoned Test & Measurement engineers.

- ISO9001 quality assurance.

Test equipment Solutions Ltd

Unit 8 Elder Way

Waterside Drive

Langley

Berkshire

SL3 6EP

T: +44 (0)1753 596000

F: +44 (0)1753 596001

Email: [email protected]

Web: www.TestEquipmentHQ.com

WaveRunner

®

Xi-A Series

2

OUTSTANDING CAPABILITIES FOR EVERYDAY TESTING

LeCroy’s “out-of-the-box” thinking about oscilloscopes provides a great form factor and no compromises. It’s loaded with capability and features that will provide more insight and help you complete your testing faster.

1. Bright, 10.4" Display

You’ll never use a small display oscilloscope again.

A fantastic viewing angle makes it easy to view.

2. Only 15 cm (6") Deep

The most space-efficient oscilloscope for your bench from 400 MHz to 1 GHz.

3. Dedicated Cursor Knobs

Select type of cursor, position them on your signal, and read values without ever opening a menu.

4. Zoom Control Knobs

Four dedicated knobs make it easy to navigate any zoom or math trace without opening menus.

5. Touch Screen with Built-in Stylus

The most time-efficient user interface is even easier to use with a built-in stylus.

6. High Impedance Active Probes

1 GHz and 1.5 GHz active probes with 0.9 pF,

1 M

Ω input impedance and an extensive probe tip and ground accessory selection.

6

1

8

9

7

10

3

4

5

2

7. LeCroy WaveStream

Fast

Viewing Mode

Provides a lively, analog-like feel similar to a phosphor trace. Adjust “trace” intensity with the front panel control, or toggle between LeCroy

WaveStream and real-time modes.

8. LeCroy WaveScan

Advanced

Search & Analysis

Use more than 20 modes to capture and search, or “scan” for anomalous events over thousands or millions of acquisitions. Use ScanHisto or

ScanOverlay to display intuitive scanned results.

9. Serial Triggering & Decoding

I

2

C SPI, UART, RS-232, AudioBus (I

2

S, LJ, RJ, TDM),

CAN, LIN, FlexRay,

™ and MIL-STD-1553 serial triggers, available for WaveRunner Xi-A.

10. “Push” Knobs

Trigger level, delay, and offset knobs all provide shortcuts to common actions when pushed.

11. Local Language User Interface

Select from 10 language preferences. Add a front panel overlay with your local language.

3

COMPLETE CAPABILITY—100% TEST COVERAGE

The LeCroy WaveRunner

Xi-A is the most powerful and capable scope available in its class.

Basic system validation using advanced triggers, fast viewing modes, measurement parameters, or serial decodes is simple and easy. Advanced debug, multi-domain analysis, and waveshape analysis are possible with tools unique to WaveRunner Xi-A.

Optional application packages help you make sense of well-defined problems.

Enhanced Understanding of Serial Data Signals

Trigger on I

2

C, SPI, UART, RS-232,

AudioBus (I

2

S, LJ, RJ, TDM), CAN,

LIN, FlexRay or MIL-STD-1553 serial data patterns. Intuitively decode values on the oscilloscope grid.

Advanced Acquisition Modes

Sequence Mode allows you to partition your acquisition memory into segments and capture specific events over long periods of time. Then, view and analyze each segment individually.

Powerful Triggers Isolate Events

An extensive collection of SMART,

Serial, and Digital (MS Series) triggers enables users to quickly and easily isolate events of interest

(some optional).

WaveScan™ Advanced

Search and Analysis

WaveScan provides the ability to locate unusual events in a single capture, or scan for an event in many acquisitions over a long period of time using more than 20 different search/scan modes.

Use ScanHisto or ScanOverlay to display intuitive scanned results.

WaveStream™ Fast

Viewing Mode

Use the high sampling rate and

WaveStream fast viewing mode to characterize signal shape, rise time, overshoot, etc., and verify the presence or absence of high-speed transients.

Completely Customizable

Quickly create your own measurement parameters or math functions using

Excel, MATLAB,

® or VBScripts (some capability optional).

Advanced Application Packages

Use a variety of application packages to provide detailed, fast solutions for specific problems.

Fast Long Memory with

Front Panel Zoom Controls

WaveRunner Xi-A’s long memory is optimized for calculation of more information 10–100x faster than other oscilloscopes, while enabling easy access to simple zooming and positioning from the front panel.

Extensive Math and

Measurement Capability

More standard and optional measurements and more powerful math capability are provided with results returned faster than in other oscilloscopes.

Beyond Time Domain Analysis

Amplify your understanding with multidomain analysis of your signals. Convert signal information into Statistical domain (Histogram), Spectral domain (long memory FFTs), Jitter, Modulation, or other Measurement Parameter domains

(Tracks of measurement parameters). (Some capability is optional.)

Integrated Tool Sets

LeCroy math, measure, and analysis tools are tightly integrated with basic scope operations. It’s easy to link capabilities and expand understanding. Free yourself from constraints!

Complete Probing Solutions

A wide variety of active FET probes, current probes, differential probes, HV probes, etc. with complete tip and ground accessories make it easy to probe your signals.

Mixed Signal

Oscilloscope Option

The MS Series can capture digital signals with speeds up to 500 MHz. View up to 36 digital channels with up to 50 Mpts/Ch memory and analyze analog and

digital events together.

Power/Amplifier

Measurements

Excellent overdrive recovery and signal integrity make

WaveRunner Xi-A ideal for high-voltage switching loss, conduction loss, ripple, switching power supply, and other amplifier measurements. Use with LeCroy

Differential Amplifiers for highperformance 100,000:1 Common-

Mode Rejection Ratio.

Timing Characterization

Extensive triggers allow fast event isolation. Measure timing statistically and view behavior graphically using histograms. Gain real understanding of root cause.

Slow/High-speed Signal Mix

Long memory, HFREJ trigger coupling, built-in noise filtering, etc.

enable fast understanding of signal behavior in circuits with a mix of slow-speed (sensor, actuator, power supply, mechanical) and high-speed signals.

5

THE MOST COMPLETE PROBLEM SOLVING OSCILLOSCOPES

6

WaveRunner Xi-A is the most complete “problem solving” oscilloscope from 400 MHz to 1 GHz with great performance, an unbelievable big display/small footprint form factor, and a multitude of fast viewing, SMART/serial data triggering, scanning, and WaveShape Analysis capabilities for fast or slow signals.

No matter what your need, you can put the precision, performance, and capability of WaveRunner Xi-A to work for you.

Great Performance

With 5 GS/s and 12.5 Mpts standard on every channel (up to 10 GS/s interleaved with 64Xi-A and 104Xi-A), you can be assured of precise measurements of fast signals, and long captures of slow-speed events.

Big Display/Small Footprint

A big display is crucial to understanding circuit behaviors, especially when working with a combination of analog, digital, and serial data signals. That’s why we use a big, bright 10.4" color display to allow room for everything, including time-correlated views of mixed-signal systems and non-time domain analysis. You’ll love the impressive display viewing angle; and the very small instrument footprint makes it easy to work anywhere.

Powerful WaveShape

Analysis Capability

WaveRunner Xi-A has the best problem-solving capability, whether you are gathering statistical data on thousands or millions of events, converting signal information into a statistical, modulation, or frequency domain for better understanding, or using WaveScan™ to find anomalous events. In addition, WaveRunner

Xi-A’s has numerous application packages to solve specific test and measurement challenges.

WaveRunner MXi-A Series

The Essential Tools for Efficient Validation and Debug

The WaveRunner

®

MXi-A not only provides the performance and tools required to debug and validate your signals, it goes deeper into your testing to help you understand the causes of complex problems.

The WaveRunner MXi-A oscilloscopes provide all of the powerful debug and analysis tools of the

MXi-A models, with the addition of advanced Math and measurements, jitter and timing analysis, and customized math and measurements.

The WaveRunner MXi-A provides all of the essential tools for efficient validation and debug.

Leading Features

400 MHz – 1 GHz Analog Bandwidths

Advanced Math and Measurement Capabilities

Jitter and Timing Analysis

Customized Math and Measurements

7

8

EMBEDDED CONTROLLER VALIDATION AND DEBUG

LeCroy’s powerful WaveRunner Xi-A oscilloscopes can be turned into high-performance mixed signal oscilloscopes (MSOs) with the addition of the MS-500 or MS-250 mixed signal oscilloscope options. In addition, I

2

C, SPI, UART, RS-232, AudioBus (I

2

S,

LJ, RJ, TDM), CAN, LIN, FlexRay, and MIL-STD-1553 triggering and decoding options turn the WaveRunner Xi-A into an all-in-one analog, digital, and serial data trigger, acquisition, and analysis machine.

High-performance Mixed

Signal Capabilities

Embedded controller design and debug involves capturing and viewing a number of different types of signals.

These signals are typically a mix of analog, digital, and serial data waveforms from a combination of analog sensors, microcontrollers and peripheral devices.

With the ability to capture digital signals with speeds up to 500 MHz and long memory of 50 Mpts/Ch the MS-500 provides unmatched mixed signal performance. For added flexibility the MS-500 supports 36 channels allowing you to view all the signals if a 16-bit micro controller plus some control lines. For applications not requiring the highest performance the MS-250 is a great value, providing

250 MHz maximum signal speed,

18 channels and 10 Mpts/Ch.

Extensive Triggering

The MS-500 and MS-250 enhance the WaveRunner Xi-A trigger capabilities. Normal oscilloscope triggers will operate on digital inputs. Cross-pattern triggering allows for simple or complex trigger patterns to be setup with any combination of analog and digital

channels. Event triggering can be configured to arm on an analog signal and trigger on a digital pattern.

Quick Mixed Signal Setup,

Easy-to-use

Unlike a traditional Logic Analyzer, the

MS-500 and MS-250 are easy to use.

A simple connection links the oscilloscope with the digital inputs so users can start viewing signals and begin debugging quickly. In addition, all standard oscilloscope tools are readily accessible. Signal debug is simple, using standard oscilloscope tools, such as cursors, measurement parameters, and zooming.

Complete I 2 C, SPI, UART,

RS-232, AudioBus (I

2

S, LJ, RJ,

TDM), CAN, LIN, FlexRay, and

MIL-STD-1553 Serial Triggering

Quickly and easily isolate specific serial data events on your embedded controller for better understanding and faster debug. Set up trigger conditions in binary, hexadecimal (Symbolic for

CAN) formats. Use the MS-500 or

MS-250 to capture serial data busses keeping the analog oscilloscope channels open for other uses. Trigger on

DATA in specific locations of long I 2 C

EEPROM reads. Get complete control of your debug process and finish faster.

Powerful Conditional

Data Triggering

Completely isolate specific message events for better understanding and debug. Use a conditional I

2

C SPI, UART,

RS-232, AudioBus (I

2

S, LJ, RJ, TDM),

CAN, LIN, FlexRay, and MIL-STD-1553

DATA trigger to select a range of DATA values to trigger on, not just a single

DATA value. Oftentimes, I 2 C utilizes

DATA bytes to specify sub-addresses for accessing memory locations in

EEPROMs. Conditional DATA trigger allows triggering on a range of DATA bytes that correspond to reads or writes to specific sub-address memory blocks in the EEPROM. It can also aid in monitoring DATA outputs from sensors, such as analog-to-digital converters, and triggering when DATA is outside a safe operating range. In both cases, verifying proper operation becomes a simple task.

Intuitive, Color-Coded

Decode Overlay

Advanced software algorithms deconstruct the waveform into binary, hex, or

ASCII protocol information, then overlay the decoded data on the waveform.

Various sections of the protocol are color-coded to make it easy to understand. The decode operation is fast— even with long acquisitions.

Table Summary and

Search/Zoom

Turn your oscilloscope into a protocol analyzer with the Table display of protocol information. Customize the table, or export Table data to an Excel file. Touch a message in the table and automatically zoom for detail. Search for specific address or data values in the acquisition.

9

EXCELLENCE IN ACQUISITION

X-Stream II Architecture

Optimized for Fast Throughput

X-Stream II architecture enables high throughput of data. X-Stream II uses variable waveform segment lengths to enable all processing intensive calculations to take place in fast CPU cache memory, thus improving calculation speed and efficiency. The result—faster processing compared to other oscilloscopes.

Optimized for Long Memory

X-Stream II essentially has no analysis memory length restrictions, regardless of analysis type, since the variable waveform segment length can always be limited to a size that can fit in CPU cache memory. Other oscilloscopes with conventional architectures cannot make this claim, and often have limitations on analysis memory of 5–20% the length of their acquisition memory under the best conditions.

Optimized for Responsiveness

By dynamically allocating buffers to maximize memory availability, the

WaveRunner Xi-A Series embodies the fastest front panel responsiveness.

A built-in processing abort makes front panel control changes instant by stopping the current process and allowing new waveforms to be positioned or zoomed— all without a lengthy recalculation.

Meanwhile, waveform previewing shows interim calculation results.

10

SMART Triggers Isolate Events

The WaveRunner Xi-A oscilloscope provides a multitude of basic and advanced (SMART) triggers to meet any need. Advanced triggers isolate specific events of interest, and (when combined with long memory) provide a complete view of the signal activity around that event. WaveRunner Xi-A excels in this regard.

Trigger on what you expect (widths, glitches, video, logic patterns, etc.) and also trigger on unusual signals

(dropouts, intervals, runts, slew rates).

LeCroy’s exclusion triggering can exclude normal signals and capture only the abnormal ones, speeding up the debug of your circuits and systems. Trigger on signals down to

1 ns in width (500 ps for width and glitch trigger), or use an “A” condition to qualify a “B” trigger.

TriggerScan™

TriggerScan uses high-speed hardware triggering capability with persistence displays to capture only the signals of interest and provide answers up to 100x faster that other methods.

Traditional fast display update modes work best on frequent events occurring on slow edge rates while Trigger-

Scan excels in finding infrequent events on fast edge rates.

Since hardware triggering is used to capture only the elusive events,

TriggerScan is more effective at finding anomalies quickly compared to simple display technologies.

A built-in automated Trigger Trainer analyzes the waveforms, identifies normal behavior, and then sets up a large set of rare event smart trigger setups that target abnormal behavior.

It then rapidly sequences through each individual trigger with a userdefined dwell time, and captures and displays any anomalous signals that meet the trigger conditions.

Sequence Mode Extends

Long Memory and SMART

Triggering Capability

Use Sequence mode to store up to

5,000 triggered events as “segments” into oscilloscope memory. This can be ideal when capturing many fast pulses in quick succession (i.e., trigger re-arm time is most important) or when capturing few events separated by long time periods (i.e., longest capture time is most important).

Sequence mode can acquire 4 channels simultaneously, provide timestamps for each acquisition (to 1 ns resolution), minimize capture dead-time (to

≤1

µ s), and allow various ways to view and analyze the captured segmented data.

Combine sequence mode with an advanced trigger to isolate a rare event, capture all instances over hours or days, and view and analyze each event afterwards.

LeCroy WaveStream

Fast Viewing Mode

WaveStream provides a vibrant, intensity graded (256 levels) display with a fast update to closely simulate the look and feel of an analog oscilloscope. WaveStream is most helpful in viewing signals that have signal jitter or signal anomalies, or for applying a visual check before creating an advanced trigger or WaveScan setup to locate an unusual event.

Since the sample rate in WaveStream mode can be as high as 10 GS/s (up to 5x that of other oscilloscopes), it is an excellent runt or glitch finder.

Timing jitter is often visually assessed to understand approximate behavior.

WaveStream makes it easy to understand jitter on edges or in eye diagrams.

WaveStream also excels in allowing you to relate composite (WaveStream) to single-event (real-time sampled) behaviors. Just capture in WaveStream mode, toggle to view or zoom a single trace, then toggle back to

WaveStream mode.

WaveScan

Advanced Search and Analysis

Finds Problems that Triggers Won’t Find.

The best trigger won’t find all unusual events—a more powerful capability is sometimes needed. WaveScan provides the ability to locate unusual events in a single capture (i.e., capture and search), or “scan” for an event in many acquisitions over a long period of time. Select from more than 20 search modes

(frequency, rise time, runt, duty cycle, etc.), apply a search condition and begin scanning. Since the scanning “modes” are not simply copies of the hardware triggers, the utility and capability is much higher. For instance, there is no “ frequency” trigger in any oscilloscope, yet WaveScan allows “frequency” to be quickly “scanned” for. This allows the user to accumulate a data set of unusual events that are separated by hours or days, enabling faster debugging.

When used in multiple acquisitions, WaveScan builds on the traditional LeCroy strength of fast processing of data. A LeCroy X-Stream oscilloscope will quickly

“scan” millions of events, looking for unusual occurrences, and do it much faster and more efficiently than other oscilloscopes can.

WaveScan in WaveRunner Xi-A also contains ScanHisto and ScanOverlay capability. Found events can be overlaid in a ScanOverlay view to provide a quick and simple comparison of events. In addition, measurement-based scanning modes (like the frequency example given above), permit ScanHistograms to show the statistical distribution of the found events. These analysis tools simplify understanding and enable faster debug.

11

UNMATCHED MEASUREMENT AND VALIDATION CAPABILITY

12

WaveRunner Xi-A provides the highest value for everyday characterization, validation, and debug, and the best capability for quickly debugging advanced problems. Whether you are debugging circuits with a mix of slow- and high-speed signals, performing signal integrity checks on highspeed clock and data signals, or doing advanced debugging of complex problems,

WaveRunner Xi-A has the right toolset that is easily applied to the problem.

Oftentimes, only viewing signals does not provide the level of precision that is required for validating designs. At those times, the ability of WaveRunner Xi-A to quickly provide precise statistical data becomes vital. With WaveRunner

Xi-A, you can quickly accumulate data on thousands of measurements in a single shot (WaveRunner Xi-A does not limit its measurements to a single value in an acquisition) or in multiple acquisitions.

Touch a button, and display statistical information. Touch another button to display a Histicon graphical view of the measurement distribution.

Expand this view into a larger histogram of measurement data.

Accumulate up to 2 billion measurement events, or create measurable persistence traces of signals with the optional WRXi-STAT.

Advanced Math Characterization

Most oscilloscopes contain only a few simple math functions to subtract waveforms or to perform coarse resolution FFTs on short record length acquisitions. Or, they provide long memory, but limited ability to process the memory and perform WaveShape

Analysis that leads to detailed understanding and faster debug.

WaveRunner Xi-A oscilloscopes contain dozens of standard math functions, and powerful capabilities, such as long memory FFTs, Trending, Tracking

(optional), Sparsing, Interpolation

selection, a variety of Persistence

Views, user customized math and measurements (MATLAB or Visual Basic formats), and numerous other specialized capabilities (optional Application

Packages). The toolset is rich and deep, and sure to solve any complex problem.

LABNOTEBOOK™

A UNIQUE TOOL FOR DOCUMENTATION AND REPORT GENERATION

The LabNotebook feature of WaveRunner Xi-A provides a report generation tool to save and document all your work. Saving all displayed waveforms, relevant WaveRunner Xi-A settings, and screen images is all done through LabNotebook, eliminat-

The screen images saved can be annotated with freehand notes using the stylus and touch screen, and then included in your report.

ing the need to navigate multiple menus to save all these files independently.

O

ne-

tou

c

h

Functi

o n a l ity

D oc u men t

Y o ur

Wo r k

S ave

Yo u r

Wo rk

R ec al l J o bs

PRINTE

R

HARD DRIVE

USB DRIVE

WAVEFORM

V/div

T/div

Memory Length

Sample Rate

Measurement

Math

OSCILLOSCOPE SET UP

EMA

IL

LABNOTEBOOK

Easy report generation helps you share your findings and communicate important results.

LabNotebook adds a simple way to report your work and save all essential waveforms, settings, and screen images.

SCREEN DUMP

Quickly save all the necessary files with

LabNotebook in a single button press.

Recall your settings from any report by using the

Flashback capability.

The WaveRunner Xi-A touch screen and stylus allow for easy annotation of the screen.

LabNotebook allows you to add freehand text and graphics in multiple colors along with printed text and arrows to help identify important parts of your waveforms and measurements.

13

MULTIDOMAIN WAVESHAPE ANALYSIS

IMPROVES UNDERSTANDING

14

The most difficult electrical circuit problems are rarely obvious in the time domain. Long memory with zooming, searching, and scanning is an important part of the solution. However, serious design professionals understand the importance of converting time-domain information into statistical, parameter, or frequency domains so as to get to the root of the problem quicker.

WaveRunner Xi-A provides you with the tools necessary to understand complex circuit problems and solve them faster.

Trend Views Turn Your

Oscilloscope Into a Strip

Chart Recorder

Slowly sample at 1000 seconds/div to capture hours of slow speed signal data. Using Trend Views, plot measurement values of high-speed signals with slower speed signals, such as transducer or voltage values.

Track Views Provide

Graphical Display of

Parameter Values vs. Time

Track in WaveRunner Xi-A (optional) uses every instance of a measurement in an acquisition to create a plot of measurement values on the Y-axis and time on the X-axis. The result is a graphical plot of a measurement change time-correlated to the original channel acquisition—perfect for intuitive understanding.

Some examples include:

• Measuring a signal’s Frequency over a 100 ms interval, and understanding whether the correct frequency shifts are present at the right times.

• Measuring a pulse width modulated (PWM) signal’s Width over a 1 second interval, and determining if the modulation circuit is correctly reacting to system changes.

• Measuring the cycle-cycle jitter values in a micro processor and understanding how cycle-cycle jitter peaks correlate to spikes in power supply lines.

The PWM signal for a power tool motor speed controller is monitored during start-up. The Width parameter is used.

All instances of Width during the acquisition are measured. Then, Track was applied to determine when the speed plateaued (i.e., when the tool rotation reached steady-state).

Histograms Graphically Present

Statistical Data

LeCroy oscilloscopes excel in capturing hundreds or thousands times more measurements per acquisition than other oscilloscopes do. With this much data, it is essential to provide more than just a list of mean, min, max, sdev, etc.

Histograms provide an intuitive way to view the distribution of statistical data and gain real insight into underlying problems. For instance:

• Measure millions of jitter values in seconds, understand whether the measurement distribution is

Gaussian or non-Gaussian, and correct timing problems to stay within a timing budget.

• Improve validation of timing budgets when measuring embedded controller response times. Measure hundreds of thousands of timing events instead of just hundreds, and easily view real-world worstcase timing situations.

A 200 MHz clock signal is acquired at 10 GS/s using 20 Mpts of acquisition data

(400,000 cycles). Cycle-Cycle and Period Jitter are measured and analyzed with Tracks and Histograms. Cycle-Cycle jitter shows a distinctive modality. Other signals could now be acquired and time-correlated to understand the histogram modality.

Fast Fourier Transforms (FFTs)

Provide Spectral Views for

Advanced Troubleshooting

LeCroy’s long memory (up to 25 Mpts)

FFTs increase your ability to understand signal behaviors in the frequency domain. The long memory allows users to obtain 5–100x the frequency resolution possible with FFTs available in other oscilloscopes, which allows more precise troubleshooting. Built-in averaging of FFTs helps to eliminate random events from the calculations.

In addition, LeCroy FFTs can be applied to any channel or math function, which greatly expands the ability to gather useful information.

Some examples include:

• Capture power supply, clock, and data signals with 1 kHz frequency resolution. Correlate power supply noise to signal integrity.

• Apply an FFT to a Track of Cycle-

Cycle Jitter and gain insight into the frequency components and root cause of the jitter.

• Quickly capture hundreds of acquisitions and average the FFTs to increase frequency signal-noise ratio and to separate random from deterministic events.

15

SPECIFIC SOLUTIONS FOR TOUGH PROBLEMS

16

Spectrum Analyzer Analysis

Package (WRXi-SPECTRUM)

SPECTRUM converts the controls of your oscilloscope to those of a spectrum analyzer. Adjust the frequency span, resolution and center frequency.

Apply filtering to your signal and watch the frequency signature change in real time. A unique peak search labels spectral components and presents frequency and level in a table. Touch any line to move to that peak.

PowerMeasure Analysis

Software Package (WRXi-PMA2)

The PMA2 software package enhances your ability to analyze power conversion devices and circuits. Measure switching and conduction losses with high accuracy. Capture power supply start-up events using long memory, view changes in the PWM signals using Track, and correlate

PWM changes to other circuit signals.

Measure power frequency harmonics and apparent/ real power and power factor. Optional accessories, such as differential amplifiers, differential probes, current probes, and deskew fixtures complete the solution.

Automotive Solutions

(CANbus TD, CANbus TDM,

WRXi-FlexRaybus TD/TDP,

WRXi-LINbus TD)

Flexible trigger on CAN, FlexRay, or LIN bus messages. Decode and display hexidecimal data values next to the signal on the screen.

Statistically analyze performance with histograms and determine root cause of timing irregularities. Vehicle

Bus Analyzer (VBAs) provide CAN symbolic level trigger and decoding, as well as FlexRay TDP and LIN trigger and decodes.

Serial Data Compliance

Packages

QualiPHY serial data compliance packages provide easy to use step by step instructions for a broad set of serial data standards, such as

USB 2.0 and Ethernet. With fast automated performance, illustrated instructions and comprehensive reporting capability, QualiPHY packages are the best solution for compliance testing.

QPHY-ENET – 100Base-TX twisted pair

active output interface mask test result.

Ethernet Application Software

Package (QPHY-ENET)

QPHY-ENET performs electrical compliance testing for 1000Base-T,

Electromagnetic Compatibility

Software Package (WRXi-EMC)

The EMC software package adds flexibility to the rise time, fall time, and width parameters necessary to accurately measure ESD pulses, EFT bursts, surges, and transients common in EMC testing. In addition, the

EMC package allows histogramming of up to 2 billion events, parameter math, and measurement filtering.

Combine this with LeCroy’s unbeatable standard statistics and measurement capability and you have a winning combination.

Jitter and Timing Analysis

Software Package (WRXi-JTA2)

Use specialized timing parameters to measure period, cycle-cycle, half period, width, etc. jitter on a variety of signals. Use the three views of jitter (statistical, time, and frequency) to understand root cause and to debug problems. Histograms (statistical view) provide understanding of statistical distributions. Tracks (time view) provide a means to show time-correlated peaks or modulations of jitter, and to compare it to other signals. FFTs (frequency view) provide the ability to debug root causes of high in-circuit jitter.

Digital Filter Software

Package (WRXi-DFP2)

DFP2 lets you implement Finite or

Infinite Impulse Response filters to eliminate undesired spectral components, such as noise, and enhances your ability to examine important signal components. The

DFP2 option allows you to choose from a standard set of FIR or IIR filters and also gives you the ability to design your own filters.

100Base-TX, and 10Base-T standards with LeCroy’s QualiPHY automated test and report software. Jitter and pulse mask tests are performed with automatic waveform alignment, and all test results feature pass/fail indicators corresponding to the standard being tested. LeCroy’s test fixture provides all three standard test loads and conditions as described in the IEEE and ANSI specifications.

USB 2.0 Compliance Test

Software Package (QPHY-USB)

The QPHY-USB package provides a complete acquisition and analysis system for USB 2.0 devices, hosts, and hubs, as specified in the USB-IF USB 2.0

Electrical Test Specification. The test software implements a full set of electrical tests for USB 2.0, including High-, Full-, and Low-speed tests and is supported by LeCroy’s

QPHY-USB – Eye diagram created using the

integrated USB-IF MATLAB

®

test scripts.

QualiPHY automated test and reporting software.

17

18

PROBES

High-performance probes are an essential tool for accurate signal capture. Consequently

LeCroy offers an extensive range of probes to meet virtually every application need. Optimized for use with LeCroy oscilloscopes, these probes set new standards for responsiveness and signal detection.

ZS Series High Impedance

Active Probes

Leading Features:

• 1 GHz (ZS1000) and 1.5 GHz

(ZS1500) bandwidths

• High Impedance (0.9 pF, 1 M

Ω)

• Extensive standard and available probe tip and ground connection accessories

• ±12 Vdc offset (ZS1500)

• LeCroy ProBus system

ADP305, ADP300

Leading Features:

• 20 MHz and 100 MHz bandwidth

• 1,000 V rms common mode voltage

• 1,400 V peak differential voltage

• EN 61010 CAT III

• 80 dB CMRR at 50/60 Hz

• LeCroy ProBus system only

CP030 and CP031

Leading Features:

• 30 A rms continuous current

• 50 or 100 MHz bandwidth

• Measure pulses up to

50 A peak

• Small form factor accommodates large conductors with small jaw size

• LeCroy ProBus system

AP031

Leading Features:

• Lowest priced differential probe

• 15 MHz bandwidth

• 700 V maximum input voltage

• Works with any 1 M

Ω input oscilloscope

AP033 and AP034

Leading Features:

• 500 MHz and 1 GHz bandwidth

• 10,000:1 CMRR

• Wide dynamic range, low noise

• LeCroy ProBus System

PPE1.2KV, PPE2KV, PPE4KV,

PPE5KV, PPE6KV, PPE20KV

Leading Features:

• Suitable for safe, accurate high-voltage measurements

• 1.2 kV to 20 kV

• Works with any 1 M

Ω input oscilloscope

SPECIFICATIONS

Standard

Math Tools

Display up to four math function traces (F1-F4). The easy-to-use graphical interface simplifies setup of up to two operations on each function trace; and function traces can be chained together to perform math-on-math.

absolute value average (summed) average (continuous) custom (MATLAB) – limited points derivative deskew (resample) difference (–) enhanced resolution (to 11 bits vertical) envelope exp (base e) exp (base 10) fft (power spectrum, magnitude, phase, up to 50 kpts) floor histogram of 1000 events integral invert (negate) log (base e) product (x) ratio (/) reciprocal rescale (with units) roof

(sinx)/x square square root sum (+) trend (datalog) of 1000 events zoom (identity)

Measure Tools

Display any 6 parameters together with statistics, including their average, high, low, and standard deviations. Histicons provide a fast, dynamic view of parameters and wave-shape characteristics.

amplitude area base cycles custom (MATLAB,

VBScript) – limited points delay

∆ delay duration duty cycle falltime (90–10%,

80–20%, @ level) first frequency last level @ x maximum mean median minimum number of points

+overshoot

–overshoot peak-to-peak period phase risetime (10–90%,

20–80%, @ level) rms std. deviation time @ level top

∆ time @ level

∆ time @ level from trigger width (positive + negative) x@ max.

x@ min.

Pass/Fail Testing

Simultaneously test multiple parameters against selectable parameter limits or pre-defined masks. Pass or fail conditions can initiate actions including document to local or networked files, e-mail the image of the failure, save waveforms, send a pulse out at the rear panel auxiliary BNC output, or

(with the GPIB option) send a GPIB SRQ.

Jitter and Timing Analysis Software Package (WRXi-JTA2)

(Standard with MXi-A model oscilloscopes)

• Jitter and timing parameters, with “Track” graphs of

– Cycle-Cycle Jitter

– N-Cycle

– N-Cycle with start selection

– Frequency

– Period

– Half Period

– Width

– Time Interval Error

– Setup

– Hold

– Skew

– Duty Cycle

– Duty Cycle Error

• Edge@lv parameter (counts edges)

• Persistence histogram, persistence trace (mean, range, sigma)

Software Options –

Advanced Math and WaveShape Analysis

Statistics Package (WRXi-STAT)

This package provides additional capability to statistically display measurement information and to analyze results:

• Histograms expanded with 19 histogram parameters/up to 2 billion events.

• Persistence Histogram

• Persistence Trace (mean, range, sigma)

Master Analysis Software Package (WRXi-XMAP)

(Standard with MXi-A model oscilloscopes)

This package provides maximum capability and flexibility, and includes all the functionality present in XMATH, XDEV, and JTA2.

Advanced Math Software Package (WRXi-XMATH)

(Standard with MXi-A model oscilloscopes)

This package provides a comprehensive set of WaveShape Analysis tools providing insight into the wave shape of complex signals. Includes:

• Parameter math – add, subtract, multiply, or divide two different parameters.

Invert a parameter and rescale parameter values.

• Histograms expanded with 19 histogram parameters/up to 2 billion events.

• Trend (datalog) of up to 1 million events

• Track graphs of any measurement parameter

• FFT capability (up to 25 Mpts) includes: power averaging, power density, real and imaginary components, and frequency domain parameters.

• Narrow-band power measurements

• Auto-correlation function

• Sparse function

• Cubic interpolation function

Advanced Customization Software Package (WRXi-XDEV)

(Standard with MXi-A model oscilloscopes)

This package provides a set of tools to modify the scope and customize it to meet your unique needs. Additional capability provided by XDEV includes:

• Creation of your own measurement parameter or math function, using third-party software packages, and display of the result in the scope.

Supported third-party software packages include:

– VBScript – MATLAB – Excel

• CustomDSO – create your own user interface in a scope dialog box.

• Addition of macro keys to run VBScript files

• Support for plug-ins

Value Analysis Software Package (WRXi-XVAP)

(Standard with MXi-A model oscilloscopes)

Measurements:

• Jitter and Timing parameters (period@level,width@level, edge@level, duty@level, time interval error@level, frequency@level, half period, setup, skew,

∆ period@level,

∆ width@level).

Math:

• Persistence histogram • Persistence trace (mean, sigma, range)

• 1 Mpts FFTs with power spectrum density, power averaging, real, imaginary, and real+imaginary settings)

Statistical and Graphical Analysis

• 1 Mpts Trends and Histograms • 19 histogram parameters

• Track graphs of any measurement parameter

Intermediate Math Software Package (WRXi-XWAV)

Math:

• 1 Mpts FFTs with power spectrum density, power averaging, real, and imaginary components

Statistical and Graphical Analysis

• 1 Mpts Trends and Histograms

• 19 histogram parameters

• Track graphs of any measurement parameter

19

20

SPECIFICATIONS

Vertical System

Nominal Analog Bandwidth

@ 50

Ω, 10 mV–1 V/div

Rise Time (Typical)

Input Channels

Bandwidth Limiters

Input Impedance

Input Coupling

Maximum Input Voltage

Vertical Resolution

Sensitivity

DC Gain Accuracy

Offset Range

Input Connector

Timebase System

Timebases

Time/Division Range

Clock Accuracy

Sample Rate and Delay Time Accuracy

Channel to Channel Deskew Range

External Sample Clock

Roll Mode

Acquisition System

Single-Shot Sample Rate/Ch

Interleaved Sample Rate (2 Ch)

Random Interleaved Sampling (RIS)

RIS Mode

Trigger Rate (Maximum)

Sequence Time Stamp Resolution

Minimum Time Between

Sequential Segments

Acquisition Memory Options

Standard

Acquisition Processing

Time Resolution (min, Single-shot)

Averaging

ERES

Envelope (Extrema)

Interpolation

Trigger System

Trigger Modes

Sources

Trigger Coupling

Pre-trigger Delay

Post-trigger Delay

Hold-off

WaveRunner WaveRunner WaveRunner WaveRunner

44Xi-A 64Xi-A 62Xi-A 104Xi-A

44MXi-A 64MXi-A 104MXi-A

400 MHz 600 MHz 600 MHz 1 GHz

875 ps

4

525 ps

4

525ps

2

350 ps

4

20 MHz; 200 MHz

1 M

Ω || 16 pF or 50 Ω

50

Ω: DC, 1 MΩ: AC, DC, GND

50

Ω: 5 V rms

, 1 M

Ω: 400 V max.

(DC + Peak AC

≤ 5 kHz)

8 bits; up to 11 with enhanced resolution (ERES)

50

Ω: 2 mV/div–1 V/div fully variable; 1 MΩ: 2 mV–10 V/div fully variable

±1.0% of full scale (typical); ±1.5% of full scale,

≥ 10 mV/div (warranted)

50

Ω: ±1 V @ 2–98 mV/div, ±10 V @ 100 mV/div–1 V/div;

1 M

Ω: ±1 V @ 2–98 mV/div, ±10 V @ 100 mV/div–1 V/div,

±100 V @ 1.02 V/div–10 V/div

50

Ω: ±400 mV @ 2–4.95 mV/div, ±1 V @ 5–99 mv/div,

±10 V @ 100 mV–1 V/div

1 M

Ω: ±400 mV @ 2–4.95 mV/div, ±1 V @

5–99 mV/div, ±10 V @ 100 mV–1 V/div,

±100 V @ 1.02–10 V/div

ProBus/BNC

50

Ω: 5 V rms

, 1 M

Ω: 250 V max.

(DC + Peak AC

≤ 10 kHz)

Internal timebase common to all input channels; an external clock may be applied at the auxiliary input

Real time: 200 ps/div–10 s/div, RIS mode: 200 ps/div to 10 ns/div, Roll mode: up to 1,000 s/div

≤ 5 ppm @ 25 °C (typical) (≤ 10 ppm @ 5–40 °C)

Equal to Clock Accuracy

±9 x time/div setting, 100 ms max., each channel

DC to 100 MHz; 50

Ω, (limited BW in 1 MΩ), BNC input, (minimum rise time and amplitude requirements apply at low frequencies)

User selectable at

≥ 500 ms/div and ≤ 100 kS/s

104Xi-A

104MXi-A

44Xi-A

44MXi-A

64Xi-A

64MXi-A

62Xi-A

5 GS/s

5 GS/s 10 GS/s

200 GS/s

User selectable from 200 ps/div to 10 ns/div

10 GS/s

1,000,000 waveforms/second

1 ns

1 µs

10 GS/s

User selectable from 100 ps/div to 10 ns/div

Max. Acquisition Points (4 Ch/2 Ch, 2 Ch/1 Ch in 62Xi-A)

12.5M/25M

44Xi-A

44MXi-A

64Xi-A

64MXi-A

62Xi-A

200 ps (5 GS/s) 100 ps (10 GS/s) 100 ps (10 GS/s)

Summed and continuous averaging to 1 million sweeps

From 8.5 to 11 bits vertical resolution

Envelope, floor, or roof for up to 1 million sweeps

Linear or (Sinx)/x

Segments (Sequence Mode)

5,000

104Xi-A

104MXi-A

100 ps (10 GS/s)

Normal, Auto, Single, Stop

Any input channel, External, Ext/10, or Line; slope and level unique to each source, except Line

DC, AC (typically 7.5 Hz), HF Reject, LF Reject

0–100% of memory size (adjustable in 1% increments, or 100 ns)

Up to 10,000 divisions in real time mode, limited at slower time/div settings in roll mode

1 ns to 20 s or 1 to 1,000,000,000 events

SPECIFICATIONS

Trigger System (cont’d)

Internal Trigger Level Range

Trigger and Interpolator Jitter

Trigger Sensitivity with Edge Trigger

(Ch 1–4 + external, DC, AC, and

LFrej coupling)

Max. Trigger Frequency with

SMART Trigger™ (Ch 1–4 + external)

External Trigger Range

Basic Triggers

Edge

TV-Composite Video

WaveRunner WaveRunner WaveRunner WaveRunner

44Xi-A 64Xi-A 62Xi-A 104Xi-A

44MXi-A 64MXi-A

400 MHz

@

≥ 10 mV

600 MHz

@

≥ 10 mV

EXT/10 ±4 V; EXT ±400 mV

104MXi-A

±4.1 div from center (typical)

≤ 3 ps rms (typical)

2 div @ < 400 MHz 2 div @ < 600 MHz 2 div @ < 600 MHz 2 div @ < 1 GHz

1 div @ < 200 MHz 1 div @ < 200 MHz 1 div @ < 200 MHz 1 div @ < 200 MHz

600 MHz

@

≥ 10 mV

1 GHz

@

≥ 10 mV

Triggers when signal meets slope (positive, negative, either, or Window) and level condition

Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate

(50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1–8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1)

SMART Triggers

State or Edge Qualified

Qualified First

Dropout

Pattern

Automatic Setup

Auto Setup

Vertical Find Scale

Triggers on any input source only if a defined state or edge occurred on another input source.

Delay between sources is selectable by time or events

In Sequence acquisition mode, triggers repeatedly on event B only if a defined pattern, state, or edge (event

A) is satisfied in the first segment of the acquisition. Delay between sources is selectable by time or events

Triggers if signal drops out for longer than selected time between 1 ns and 20 s.

Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input – 2 Ch+EXT on WaveRunner 62Xi-A). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern

SMART Triggers with Exclusion Technology

Glitch and Pulse Width

Signal or Pattern Interval

Timeout (State/Edge Qualified)

Runt

Slew Rate

Exclusion Triggering

Triggers on positive or negative glitches with widths selectable from 500 ps to 20 s or on intermittent faults

(subject to bandwidth limit of oscilloscope)

Triggers on intervals selectable between 1 ns and 20 s

Triggers on any source if a given state (or transition edge) has occurred on another source.

Delay between sources is 1 ns to 20 s, or 1 to 99,999,999 events

Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between

1 ns and 20 s

Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 s

Trigger on intermittent faults by specifying the normal width or period

LeCroy WaveStream Fast Viewing Mode

Intensity

Number of Channels

Max Sampling Rate

Waveforms/second (continuous)

Operation

256 Intensity Levels, 1–100% adjustable via front panel control up to 4 simultaneously

5 GS/s (10 GS/s for WR 62Xi-A, 64Xi-A/64MXi-A,104Xi-A/104MXi-A, 204Xi-A/204MXi-A in interleaved mode)

Up to 20,000 waveforms/second

Front panel toggle between normal real-time mode and LeCroy WaveStream Fast Viewing mode

Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals

Automatically sets the vertical sensitivity and offset for the selected channels to display a waveform with maximum dynamic range

Probes

Probes

Probe System; ProBus

Scale Factors

Color Waveform Display

Type

Resolution

Number of Traces

Grid Styles

Waveform Styles

One Passive probe per channel; Optional passive and active probes available

Automatically detects and supports a variety of compatible probes

Automatically or manually selected, depending on probe used

Color 10.4" flat-panel TFT-LCD with high resolution touch screen

SVGA; 800 x 600 pixels; maximum external monitor output resolution of 2048 x 1536 pixels

Display a maximum of 8 traces. Simultaneously display channel, zoom, memory, and math traces

Auto, Single, Dual, Quad, Octal, XY, Single + XY, Dual + XY

Sample dots joined or dots only in real-time mode

21

22

SPECIFICATIONS

Zoom Expansion Traces

Internal Waveform Memory

Setup Storage

Front Panel and Instrument Status

Interface

Remote Control

Network Communication Standard

GPIB Port (Accessory)

Ethernet Port

USB Ports

External Monitor Port

Auxiliary Input

Signal Types

Coupling

Maximum Input Voltage

Auxiliary Output

Signal Type

Output Level

Connector Type

General

Auto Calibration

Calibrator

Power Requirements

Environmental

Temperature: Operating

Temperature: Non-Operating

Humidity: Operating

Humidity: Non-Operating

Altitude: Operating

Altitude: Non-Operating

Physical

Dimensions (HWD)

Net Weight

Certifications

Warranty and Service

WaveRunner WaveRunner WaveRunner WaveRunner

44Xi-A 62Xi-A

44MXi-A

64Xi-A

64MXi-A

104Xi-A

104MXi-A

Display up to 4 Zoom/Math traces with 16 bits/data point

M1, M2, M3, M4 Internal Waveform Memory (store full-length waveform with 16 bits/data point) or store to any number of files limited only by data storage media

Store to the internal hard drive, over the network, or to a USB-connected peripheral device

Via Windows Automation, or via LeCroy Remote Command Set

VXI-11 or VICP, LXI Class C Compliant

Supports IEEE – 488.2

10/100/1000Base-T Ethernet interface (RJ-45 connector)

5 USB 2.0 ports (one on front of instrument) supports Windows-compatible devices

Standard 15-pin D-Type SVGA-compatible DB-15; connect a second monitor to use extended desktop display mode with XGA resolution

44Xi-A

44MXi-A

64Xi-A

64MXi-A

62Xi-A 104Xi-A

104MXi-A

Selected from External Trigger or External Clock input on front panel

50

Ω: DC, 1 MΩ: AC, DC, GND

50

Ω: 5 V rms

, 1 M

Ω: 400 V max.

(DC + Peak AC

≤ 5 kHz)

50

Ω: 5 V rms

, 1 M

Ω: 250 V max.

(DC + Peak AC

≤ 10 kHz)

Trigger Enabled, Trigger Output. Pass/Fail, or Off

TTL,

≈3.3 V

BNC, located on rear panel

Ensures specified DC and timing accuracy is maintained for 1 year minimum

Output available on front panel connector provides a variety of signals for probe calibration and compensation

90–264 V rms at 50/60 Hz; 115 V rms

(±10%) at 400 Hz, Automatic AC Voltage Selection

Installation Category: 300 V CAT II; Max. Power Consumption: 340 VA/340 W for all models (both 4CH and 2CH)

+5 °C to +40 °C

-20 °C to +60 °C

Maximum relative humidity 80% for temperatures up to 31 °C decreasing linearly to 50% relative humidity at 40 °C

5% to 95% RH (non-condensing) as tested per MIL-PRF-28800F

Up to 3,048 m (10,000 ft.) @

≤ 25 °C

Up to 12,190 m (40,000 ft.)

260 mm x 340 mm x 152 mm Excluding accessories and projections (10.25" x 13.4" x 6")

7.26 kg. (16.0 lbs.)

CE Compliant, UL and cUL listed; Conforms to EN 61326, EN 61010-1, UL 61010-1 2nd Edition, and CSA C22.2 No. 61010-1-04

3-year warranty; calibration recommended annually. Optional service programs include extended warranty, upgrades, calibration, and customization services

ORDERING INFORMATION

Product Description

WaveRunner Xi-A Series Oscilloscopes

1 GHz, 4 Ch, 5 GS/s, 12.5 Mpts/Ch

(10 GS/s, 25 Mpts/Ch in interleaved mode) with 10.4" Color Touch Screen Display

600 MHz, 4 Ch, 5 GS/s, 12.5 Mpts/Ch

(10 GS/s, 25 Mpts/Ch in interleaved mode) with 10.4" Color Touch Screen Display

600 MHz, 2 Ch, 5 GS/s, 12.5 Mpts/Ch

(10 GS/s, 25 Mpts/Ch in interleaved mode) with 10.4" Color Touch Screen Display

400 MHz, 4 Ch, 5 GS/s, 12.5 Mpts/Ch

(25 Mpts/Ch in interleaved mode) with 10.4" Color Touch Screen Display

Product Code

WaveRunner 104Xi-A

WaveRunner 64Xi-A

WaveRunner 62Xi-A

WaveRunner 44Xi-A

WaveRunner MXi-A Series Oscilloscopes

1 GHz, 4 Ch, 5 GS/s, 12.5 Mpts/Ch

(10 GS/s, 25 Mpts/Ch in Interleaved Mode) with 10.4" Color Touch Screen Display

600 MHz, 4 Ch, 5 GS/s, 12.5 Mpts/Ch

(10 GS/s, 25 Mpts/Ch in Interleaved Mode) with 10.4" Color Touch Screen Display

400 MHz, 4 Ch, 5 GS/s, 12.5 Mpts/Ch

(25 Mpts/Ch in Interleaved Mode) with 10.4" Color Touch Screen Display

WaveRunner 104MXi-A

WaveRunner 64MXi-A

WaveRunner 44MXi-A

Included with Standard Configuration

÷10, 500 MHz, 10 M

Ω Passive Probe (Total of 1 Per Channel)

Standard Ports; 10/100/1000Base-T Ethernet, USB 2.0 (5),

SVGA Video out, Audio in/out, RS-232

Optical 3-button Wheel Mouse – USB 2.0

Protective Front Cover

Accessory Pouch

Getting Started Manual

Quick Reference Guide

Anti-virus Software (Trial Version)

Commercial NIST Traceable Calibration with Certificate

3-year Warranty

General Purpose Software Options

Statistics Software Package

Master Analysis Software Package

(Standard with MXi-A model oscilloscopes)

WRXi-STAT

WRXi-XMAP

Advanced Math Software Package

(Standard with MXi-A model oscilloscopes)

Intermediate Math Software Package

(Standard with MXi-A model oscilloscopes)

Value Analysis Software Package (Includes XWAV and JTA2)

(Standard with MXi-A model oscilloscopes)

Advanced Customization Software Package

(Standard with MXi-A model oscilloscopes)

Spectrum Analyzer and Advanced FFT Option

Processing Web Editor Software Package

WRXi-XMATH

WRXi-XWAV

WRXi-XVAP

WRXi-XDEV

WRXi-SPECTRUM

WRXi-XWEB

Application Specific Software Options

Jitter and Timing Analysis Software Package

(Standard with MXi-A model oscilloscopes)

Digital Filter Software Package

Disk Drive Measurement Software Package

PowerMeasure Analysis Software Package

Serial Data Mask Software Package

WRXi-JTA2

WRXi-DFP2

WRXi-DDM2

WRXi-PMA2

WRXi-SDM

Product Description Product Code

Application Specific Software Options (cont’d)

QualiPHY Enabled Ethernet Software Option QPHY-ENET*

QualiPHY Enabled USB 2.0 Software Option

QualiPHY Enabled MOST150o Software Option

QPHY-USB

QPHY-MOST150o

QualiPHY Enabled MOST50e Software Option QPHY-MOST50e

QualiPHY Enabled BroadR-Reach Software Option QPHY-BroadR-Reach*

EMC Pulse Parameter Software Package

Electrical Telecom Mask Test Package

WRXi-EMC

ET-PMT

* TF-ENET-B required. † TF-USB-B required.

Serial Data Options

I 2 C Trigger and Decode Option

SPI Trigger and Decode Option

UART and RS-232 Trigger and Decode Option

LIN Trigger and Decode Option

WRXi-I2Cbus TD

WRXi-SPIbus TD

WRXi-UART-RS232bus TD

WRXi-LINbus TD

CANbus TD Trigger and Decode Option CANbus TD

CANbus TDM Trigger, Decode, and Measure/Graph Option CANbus TDM

FlexRay Trigger and Decode Option WRXi-FlexRaybus TD

FlexRay Trigger and Decode Physical Layer

Test Option

Vehicle Bus Analyzer Package - includes CANbus TDM,

FlexRay TDP, LINBus TD, and ProtoBus MAG

WRXi-FlexRaybus TDP

WRXi-VBA

Audiobus Trigger and Decode Option for I

2

S, LJ, RJ, and TDM

Audiobus Trigger, Decode, and Graph Option for I

2

S LJ, RJ, and TDM

WRXi-Audiobus TD

WRXi-Audiobus TDG

MIL-STD-1553 Trigger and Decode Option

USB2-HSIC Decode Option

WRXi-1553 TD

WRXi-USB2-HSICbus D

A variety of Vehicle Bus Analyzers based on the WaveRunner Xi-A platform are available.

These units are equipped with a Symbolic CAN trigger and decode.

Mixed Signal Oscilloscope Options

500 MHz, 18 Ch, 2 GS/s, 50 Mpts/Ch

Mixed Signal Oscilloscope Option

250 MHz, 36 Ch, 1 GS/s, 25 Mpts/Ch

(500 MHz, 18 Ch, 2 GS/s, 50 Mpts/Ch Interleaved)

Mixed Signal Oscilloscope Option

250 MHz, 18 Ch, 1 GS/s, 10 Mpts/Ch

Mixed Signal Oscilloscope Option

MS-500

MS-500-36

MS-250

Probes and Amplifiers*

Set of 4 ZS1500, 1.5 GHz, 0.9 pF, 1 M

High Impedance Active Probe

Set of 4 ZS1000, 1 GHz, 0.9 pF, 1 M

High Impedance Active Probe

1 GHz Active Differential Probe (÷1, ÷10, ÷20)

ZS1500-QUADPAK

ZS1000-QUADPAK

500 MHz Active Differential Probe (x10, ÷1, ÷10, ÷100)

30 A; 100 MHz Current Probe – AC/DC; 30 A rms

; 50 A rms

Pulse

30 A; 50 MHz Current Probe – AC/DC; 30 A rms

; 50 A rms

Pulse

30 A; 50 MHz Current Probe – AC/DC; 30 A rms

; 50 A peak

Pulse

150 A; 10 MHz Current Probe – AC/DC; 150 A rms

; 500 A peak

Pulse

500 A; 2 MHz Current Probe – AC/DC; 500 A rms

; 700 A peak

Pulse

1,400 V, 100 MHz High-Voltage Differential Probe

1,400 V, 20 MHz High-Voltage Differential Probe

1 Ch, 100 MHz Differential Amplifier

AP034

AP033

CP031

CP030

AP015

CP150

CP500

ADP305

ADP300

DA1855A

*A wide variety of other passive, active, and differential probes are also available.

Consult LeCroy for more information.

23

ORDERING INFORMATION

Product Description Product Code

Hardware Accessories*

10/100/1000Base-T Compliance Test Fixture

USB 2.0 Compliance Test Fixture

External GPIB Interface

Soft Carrying Case

Hard Transit Case

Mounting Stand – Desktop Clamp Style

Rackmount Kit

Mini Keyboard

Removable Hard Drive Package (Includes removeable hard drive kit and two hard drives)

Additional Removable Hard Drive

* A variety of local language front panel overlays are also available

.

† Includes ENET-2CAB-SMA018 and ENET-2ADA-BNCSMA.

TF-ENET-B

TF-USB-B

WS-GPIB

WRXi-SOFTCASE

WRXi-HARDCASE

WRXi-MS-CLAMP

WRXi-RACK

WRXi-KYBD

WRXi-A-RHD

WRXi-A-RHD-02

Customer Service

LeCroy oscilloscopes and probes are designed, built, and tested to ensure high reliability. In the unlikely event you experience difficulties, our digital oscilloscopes are fully warranted for three years, and our probes are warranted for one year.

This warranty includes:

• No charge for return shipping

• Long-term 7-year support

• Upgrade to latest software at no charge

1-800-5-LeCroy www.lecroy.com

Local sales offices are located throughout the world.

Visit our website to find the most convenient location.

© 2012 by LeCroy Corporation. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice. Product or brand names are trademarks or requested trademarks of their respective holders.