DATA SHEET 2115-125 Block Upconverter, 12.2 - 12.75 GHz 12/06/07

DATA SHEET
CROSS TECHNOLOGIES, INC.
REV_A 12/06/07
2115-125 Block Upconverter, 12.2 - 12.75 GHz
The 2115-125 Block Upconverter converts 0.95 - 1.5 GHz to 12.2 - 12.75 GHz with a local oscillator at 11.25 GHz. Front panel LEDs
provide indication of DC Power, External 10 MHz, and PLL Alarm. The L-band to RF gain is +20 dB. Connectors are SMA female for the
RF and BNC female for the L-Band and external reference input and reference output. A three-way switch controls which 10 MHz
reference is being used. In the INT position, the internal reference is used, in the EXT position, the external reference is used, and in the
AUTO position, the internal reference is used unless a +3 dBm ± 3 dB, 10MHz reference signal is connected to the external reference
input. The 2115 is powered by a 90-260 VAC power supply, and mounted in a 1 3/4” X 19 “ X 14” rack mount chassis.
MODEL 2115
UPCONVERTER
(SHOWN WITH OPTIONAL
VARIABLE ATTENUATOR)
EXT
10MHZ
CROSS TECHNOLOGIES INC.
ALARM POWER
AC
RF OUTPUT
10MHZ REF
EXT 10MHZ
INPUT
OUTPUT
AUTO
GND
INT
L-BAND
INPUT
ALARM
EXT
5 4 3 2 1
9 8 7 6
J101
J2
S1
J8
J1
J11
Front and Rear Panels
EQUIPMENT SPECIFICATIONS*
Input Characteristics
Impedance/Return Loss
Frequency
Noise Figure, Max.
Input Level range
dBm
Input 1 dB compression
Output Characteristics
Impedance/Return Loss
Frequency
Output Level Range
Channel Characteristics
Gain
Image Rejection
Spurious, Inband
Spurious, Out of band
Intermodulation
Frequency Response
Frequency Sense
LO Characteristics
LO Frequency
Frequency Accuracy
Phase Noise @ F (Hz) >
dBC/Hz
10 MHz level
Controls, Indicators
Attenuator Option -VA
Ext 10 MHz
PLL Alarm
Power
Other
RF Connector
L-Band Connector
10 MHz connectors
Alarm Connector
Size
Power
0.95
to
1.5
GHz
IN
50/14 dB
0.95 to 1.5 GHz
20 dB max gain
-40 to -25
VAR ATT
(OPTION)
A
T
T
2 GHz LP
11.25
GHz
12.2 to 12.75
GHz BP
.12.2 to
12.75
GHz
OUT
EXT
10 M
-15 dBm
10 M
MON
50 /14 dB
12.2 to 12.75 GHz
-20 to -5 dBm
2115-125 Upconverter Block Diagram
+20 ±1 dB, (+20 to +5 dB continuously variable with Variable Attenuator Option)
> 60 dB, min
SIGNAL RELATED<-60 dBC in band, -5 dBm out; SIGNAL INDEPENDENT,<-60 dBm
<-50 dBm
<-50 dBC for two carriers each at -10 dBm out
±1 dB, 12.2 - 12.75 GHz out; ± 0.5 dB, 40 MHz BW
Non-inverting
11.25 GHz
± 0.01 ppm max over temp internal reference; ext. ref. input
100
-70
1K
-80
10K
-85
100K
-100
1M
-110
+3 dBm, ± 3 dB, 75 ohms, External In or Internal out
Provides +20 to +5 dB continuously variable gain via front panel variable potentiometer.
Yellow LED, indicates external 10 MHz reference selected (rear panel DPDT switch)
Red LED, External contact closure
Available Connector Options
Green LED
M - 50 N-type (RF), 50 BNC (L-BAND)
SMA (female), 50
N - 50 N-type (RF), 75 BNC (L-BAND)
BNC (female), 50
NF - 50 N-type (RF), 75 F-type (L-BAND)
BNC (female), 75 connector;Works for 50 or 75 NN - 50 N-type (RF), 50 N-type (L-BAND)
DB9 - NO or NC contact closure on Alarm
S7 - 50 SMA (RF), 75 BNC (L-BAND)
19 inch standard chassis 1.75” high X 14.0” deep
SF- 50 SMA (RF), 75 F-type (L-BAND)
100-240 ±10% VAC, 47 - 63 Hz, 25 watts max.
SN - 50 SMA (RF), 50 N-type (L-BAND)
*+10 to +40 degrees C; Specifications subject to change without notice
SS - 50 SMA (RF), 50 SMA (L-BAND)
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road, Alpharetta, Georgia 30005
770-886-8005, FAX 770-886-7964
www.crosstechnologies.com
Download PDF