Pedestal Connectors and Covers C36–C42

Homac
®
Underground Distribution
Pedestal Connectors and Covers
Aluminum Lay-In Pedestal Connectors
Effortlessly install or remove large, stiff cables in confined areas
• Minimizes the hassle and hazards of having to force cables into the closed cable ports
found on conventional mechanical connectors. You save time and labor.
• No crimping tools or dies or other special tools are needed for installation.
Use with aluminum or copper cable.
• Ensure even force distribution in the cable/connector interface
Cat. No.
Conductor Range
ABCK 6350
Outlets
#6–350
ABCK 6600
#2–600
ABCK 6600 DS*
6
* “-DS” suffix indicates double set screws.
1-3⁄8
7
ABCK 6350
1-3⁄8
8-7⁄8
ABCK 6600
C36
w w w. tnb.c a
Homac
®
Underground Distribution
Pedestal Connectors and Covers
Aluminum Set-Screw Bar Pedestal Connectors —
Single-Line Bar
Available with up to eight outlets for aluminum
or copper conductors
• Accepts aluminum or copper conductors
• Ensure maximum conductor contact pressure. Also break up interstrand oxides.
• Meets or exceeds ANSI C119.4 specifications
ABC 4350
L
Cat. No.
Outlets
Length
ABC 240
2
1-11/16
ABC 340
3
2-9/16
ABC 440
4
3-7/16
ABC 540
5
4-5/16
ABC 640
6
5-3/16
ABC 740
7
6-1/16
ABC 840
8
6-15/16
ABC 2350
2
2
ABC 3350
3
3
ABC 4350
4
4
ABC 5350
5
5
ABC 6350
6
6
ABC 7350
7
7
ABC 8350
8
8
ABC 2500
2
2-1/16
ABC 3500
3
3-1/16
ABC 4500
4
4-1/16
ABC 5500
5
5-1/16
ABC 6500
6
6-1/16
ABC 7500
7
7-1/16
ABC 8500
8
8-1/16
ABC 2750
2
2-3/4
ABC 3750
3
4-3/16
ABC 4750
4
5-9/16
ABC 5750
5
7
BB 12
ABC 6750
6
8-3/8
BB 14
Boot Number
Cable Range
BB 10
BB 11
#6–250
BB 12
BB 10
BB 11
#12–350
BB 12
BB 10
BB 11
#6–500
BB 12
BB 14
BB 10
BB 13
1/0–750
ABC 7750
7
9-13/16
BB 15
ABC 8750
8
11-3/16
For oxide-inhibitor option, add “-C” suffix to the catalogue number. For streetlight-outlet option,
add “-SL” suffix to the catalogue number. For insulating covers, see page C42.
For special applications, please consult your Thomas & Betts representative.
TM
For EZ Torque (shear-head screws) supplied in all outlets,
add “-TS” suffix to the catalogue number.
w w w. tnb.c a
C37
Homac
®
Underground Distribution
Pedestal Connectors and Covers
Aluminum Set-Screw Bar Pedestal Connectors —
Double-Row Bar
High-strength aluminum alloy maintains
constant bolting pressure on conductors
• Accepts aluminum or copper conductors
• Ensure maximum conductor contact pressure. Also break up interstrand oxides.
• Meets or exceeds ANSI C119.4 specifications
FB 33 Boot
ABC 500-33
Cat. No.
Outlets
Length
ABC 40-22
4
1-5/8
ABC 40-33
6
2-7/16
ABC 40-44
8
3-3/16
ABC 350-22
4
2-1/8
ABC 350-33
6
3
ABC 350-44
8
3-15/16
ABC 500-22
4
2-1/16
ABC 500-33
6
3-1/16
ABC 500-44
8
4-1/16
ABC 750-22
4
2-3/4
ABC 750-33
6
4-3/16
ABC 750-44
8
5-9/16
Width
2
Boot Number Cable Range
BB 17
L
#6–250
FB 33*
2-1/2
2-3/8
BB 17
#12–350
2-3/4
3-1/4
W
FB 33*
#6–500
–**
1/0–750
* EPDM Flexi-Boot, see page C42.
** For other insulating covers, please consult your Thomas & Betts representative.
For oxide-inhibitor option, add “-C” suffix to the catalogue number.
For streetlight-outlet option, add “-SL” suffix to the catalogue number.
For special applications, please consult your Thomas & Betts representative.
C38
w w w. tnb.c a
Homac
®
Underground Distribution
Pedestal Connectors and Covers
Aluminum Pedestal Connectors
Insulated and uninsulated pedestal connectors with up to 10 outlets
•
•
•
•
•
•
Doubles cable capacity
Enables safe installations and disconnects — and provides insulation
All screws are on top, and a 5⁄16 in. hex wrench is all you need
Accepts aluminum or copper conductors
Ensure maximum conductor contact pressure. Also break up interstrand oxides.
Meets or exceeds ANSI C119.4 specifications
Insulated
Cat. No.
Uninsulated
Cat. No.
ZVB 2023
ZVB 3033
Outlets
L
ZBC 2023
4
2-1/4
ZBC 3033
6
3-1/4
ZVB 4043
ZBC 4043
8
4-1/4
ZVB 5053
ZBC 5053
10
5-1/4
ZVB 2025
ZBC 2025
4
2-7/16
ZVB 3035
ZBC 3035
6
3-9/16
ZVB 4045
ZBC 4045
8
4-11/16
ZVB 5055
ZBC 5055
10
5-13/16
Cable Range
ZVB 5053
L
#12–350
#6–500
For oxide-inhibitor option, add “-C” suffix to the catalogue number.
For a kit containing 1 uninsulated and 2 insulated connectors,
add “-K” suffix to the catalogue number.
w w w. tnb.c a
C39
Homac
®
Underground Distribution
Pedestal Connectors and Covers
Aluminum Multi-Tap Encapsulated
Cable Blocks — One-Way Configuration
These dual-rated blocks can be used with copper or aluminum cables
• Wide range of cable sizes and number of outlets available in one-way configurations
• Safe and time-saving installation with no taping required
• UL Listed. Meets or exceeds ANSI C119.4 specifications.
CSB 250-5 S
Dimensions (in.)
Cat. No.
No. of Outlets
Wire Range
Screw Size
Length
CSB 4-2 S
CSB 4-3 S
CSB 4-4 SAH*
CSB 4-5 S
CSB 4-6 S
CSB 4-7 S
CSB 4-8 SAH*
CSB 2/0-2 S
CSB 2/0-3 S
CSB 2/0-4 S
CSB 2/0-5 S
CSB 2/0-6 S
CSB 2/0-7 S
CSB 2/0-8 S
CSB 250-2 S
CSB 250-3 S
CSB 250-4 S
CSB 250-5 S
CSB 250-6 S
CSB 250-7 S
CSB 250-8 S
CSB 350-2 S
CSB 350-3 S
CSB 350-4 S
CSB 350-5 S
CSB 350-6 S
CSB 350-7 S
CSB 350-8 S
CSB 500-2 S
CSB 500-3 S
CSB 500-4 S
CSB 500-5 S
CSB 500-6 S
CSB 500-7 S
CSB 500-8 S
2
3
4
5
6
7
8
2
3
4
5
6
7
8
2
3
4
5
6
7
8
2
3
4
5
6
7
8
2
3
4
5
6
7
8
#4–#14
Slotted
2/0–#14
3/16 Hex
250–#6
5/16 Hex
350–#10
5/16 Hex
500–#6
5/16 Hex
1-1/8
1-9/16
2-1/16
2-9/16
3-1/16
3-9/16
4-1/16
1-5/8
2-3/8
3-1/8
3-7/8
4-5/8
5-3/8
6-1/8
1-7/8
2-27/32
3-13/16
4-25/32
5-3/4
6-3/4
7-45/64
2-1/4
3-1/4
4-1/4
5-1/4
6-1/4
7-1/4
8-1/4
2-7/8
4-1/8
5-3/8
6-5/8
7-7/8
9-1/8
10-3/8
Width
Height
1-5/8
1-5/16
1-3/4
1-3/8
2-5/8
2-1/8
3-1/8
2-1/2
3-3/16
2-3/4
* Not UL Listed, includes hex screw.
C40
w w w. tnb.c a
Homac
®
Underground Distribution
Pedestal Connectors and Covers
Aluminum Multi-Tap Encapsulated Cable Blocks —
Two-Way Configuration
These dual-rated blocks can be used
with copper or aluminum cables
• Wide range of cable sizes and number of outlets available in one-way configurations
• Safe and time-saving installation with no taping required
• UL Listed. Meets or exceeds ANSI C119.4 specifications.
CSB 500-8
Dimensions (in.)
Cat. No.
No. of Outlets
Wire Range
Screw Size
Length
CSB 4-2
CSB 4-3
CSB 4-4
CSB 4-5
CSB 4-6
CSB 4-7
CSB 4-8
CSB 2/0-2
CSB 2/0-3
CSB 2/0-4
CSB 2/0-5
CSB 2/0-6
CSB 2/0-7
CSB 2/0-8
CSB 250-2
CSB 250-3
CSB 250-4
CSB 250-5
CSB 250-6
CSB 250-7
CSB 250-8
CSB 350-2
CSB 350-3
CSB 350-4
CSB 350-5
CSB 350-6
CSB 350-7
CSB 350-8
CSB 500-2
CSB 500-3
CSB 500-4
CSB 500-5
CSB 500-6
CSB 500-7
CSB 500-8
CSB 750-2
CSB 750-3
CSB 750-4
CSB 750-5
CSB 750-6
CSB 750-7
CSB 750-8
CSB 750-9
CSB 750-10
w w w. tnb.c a
2
3
4
5
6
7
8
2
3
4
5
6
7
8
2
3
4
5
6
7
8
2
3
4
5
6
7
8
2
3
4
5
6
7
8
2
3
4
5
6
7
8
9
10
#4–#14
Slotted
2/0–#14
3/16 Hex
250–#6
5/16 Hex
350–#10
3/8 Hex
500–#6
3/8 Hex
750–1/0
3/8 Hex
1-1/8
1-9/16
2-1/16
2-9/16
3-1/16
3-9/16
4-1/16
1-5/8
2-3/8
3-1/8
3-7/8
4-5/8
5-3/8
6-1/8
1-7/8
2-27/32
3-13/16
4-25/32
5-3/4
6-3/4
7-45/64
2-1/4
3-1/4
4-1/4
5-1/4
6-1/4
7-1/4
8-1/4
2-7/8
4-1/8
5-3/8
6-5/8
7-7/8
9-1/8
10-3/8
3
4-7/16
5-3/16
7-1/4
8-5/8
10
11-7/16
12-13/16
14-1/4
Width
Height
1-5/8
1-5/16
1-3/4
1-3/8
2-5/8
2-1/8
3-1/8
2-1/2
3-3/16
2-3/4
3-3/8
2-1/4
C41
Homac
®
Underground Distribution
Pedestal Connectors and Covers
Insulated Aluminum Pedestal Connectors
See the connector through the transparent insulator
• No lost parts to worry about
• Safer connections — the connector securely locks in cover while the
cable outlets self adjust
• Approved by the Federal government for utility use
CLR 6350
Cat. No.
Outlets
CLR 340
CLR 440
CLR 540
CLR 640
CLR 3350
CLR 4350
CLR 5350
CLR 6350
Wire Range
3
4
5
6
3
4
5
6
#12–4/0
#12–350
Insulating Covers for Set-Screw Bar Pedestal Connectors
Rugged insulating covers to protect pedestal connectors
• Boot will not crack from cold embrittlement, will not cold flow and will not soften with heat
• Locking ribs prevent accidental removal of EPDM cover
EPDM Rubber FB Series
Cat. No.
Height
Length
Width
5-1/4
3-1/2
4-3/4
7-1/4
3-3/8
2-1/16
FB 33
FB 6 L
FB 6 L
FB 33
PVC BB Series
Cat. No.
Height
BB 10
BB 11
BB 12
BB 13
BB 14
BB 15
BB 17
3-5/16
2-7/8
Height-1
1-3/8
3-3/4
1-7/8
6-7/8
2-1/8
Length
4-1/8
5-7/8
7-3/4
5-15/16
8-5/8
11-11/16
3-1/8
H-1
Width
2-1/8
H
H
H-1
2-1/4
2-3/4
3-1/16
Polyethylene PB Series
Cat. No.
Height
Length
Width
PB 2
PB 1 P
8
4
4
6-1/4
4-3/16
2-7/8
For cover sizes not listed, please consult your Thomas & Betts representative.
All boots have a nominal wall thickness of 1⁄8 in.
All sizes given for BB and PB series are inside dimensions.
C42
PB 2
PB 1 P
w w w. tnb.c a
Download PDF