vacon x series
rugged drives for the real world
1
the toughest ac drives on the planet!
The Vacon X4 and X5 AC Drives are designed for REAL world that is not gentle or forgiving to electronic products. They have been designed to keep driving in harsh environments and are built from
the ground up to survive hostile conditions and still be simple to use. They are built to be mounted
where the work is, not hidden in another enclosure or room that adds costs and space.
The same enclosures that can survive in the harsh industrial
world makes them ideal when cleanliness is extremely important, such ass the Food and Beverage industry where high
pressure washin
ngs are needed on a regular basis. The Vacon
washings
X4 and X5 drives, through 100 HP, exceed the specifications
of their rated NEMA
NE
EMA 4X / IP66 Indoor and Outdoor Use enclosures. AND all models up through 30 HP can withstand high
pressure washd
down of 1,000 PSI at 6 inches!
washdown
The Vacon X Se
eries drives have the brains to go with their
Series
brawn. All models are packed with advanced control and
operation features
featurres that make them the best choice for everything from simple, stand-alone applications to advanced
system-level controls.
The Vacon X Series drives also boast the easiest programming and operat
tion in the industry. The bright, clear, backlit
operation
display providess an easy to read and customizable view for
operation and programming.
prrogramming. The Vacon X Series
ries keypad has
arge, well marked
mark
ked buttons to control all aspects of the drive
large,
operation and
nd programming.
prrogramming.
2
The Vacon X4 has the toughness and features to handle
handle most
industrial jobs with ease. If the application is more unique,
the X5 accepts option boards, and hass a USB interface,
inte
erface, fully
coated PC boards for added
ed protection and other
othe
er advanced
features such as a real-time-clock.
A tough enclosure, an easy to read display, simple programprogram
ming and the confidence of knowing you can mount the drive
almost anywhere make the Vacon X4 and Vacon X5 drives the
only choice.
Toughest packaging
Tou
• NEMA
NE
4X / IP66 Indoor and Outdoor Use enclosures through
100 HP; NEMA 12 / IP55 for 125 HP and above
• Wi
Withstands 1,000 PSI washdown at 6 inches on models
tho
though
30 HP
• Thick
Th injected foam and metal covers protect against bumps
an
and misuse
• Mo
Mounts close to the motor to eliminate long motor lead
pro
problems
Easiest to use
Eas
• Simple
Sim
intuitive programming
• Multi-language
Mu
display – no codes to learn
• Wi
Wireless programming using PDA-trAC+® for Windows
Mo
Mobile 5®
• Application
Ap
Marcos make set-up a breeze
Most versatile
Mos
• Operate
Op
form keypad, remote signals, computers or any
com
combination
• Mount
Mo
them where you use them
• Built-in
B
Bu
9-step PLC functions (25-step with X5)
• AR
ARCTIC Mode maintains safe operating temperature in cold
loc
locations
3
simple to operate
Basic operations are a breeze with Vacon's enhanced keypad.
The familiar design uses color-coded buttons with text and
symbols, remains easy-to-use and understand, yet offers an
unprecedented breadth of functionality. With a few simple
touch commands, operators have access to parameters for
configuration, start-up, operation and troubleshooting.
• Run set-up macros for fan, pump, or sensorless vector
applications with real time clock capabilities. Collect real
time data and event logs using a choice of communication
protocols or through the standard USB port.
• Expand the basic operations with predefined macro
commands that simplify common application set ups.
One-touch menu selection collects the most frequently
used parameters and presets them with common application
settings. Collect real time data and event logs using a
choice of communication protocols or through standard
USB port.
PDA-trAC+® software allows Pocket PC devices with infrared networking capabilities to be used for accurate product
configuration. No more need for special cables, adapters or
opening enclosures to change a setting! Download your free
copy from our web site: www.vacon.com
4
Vacon’s user-friendly keypad makes operation simple.
The easy-to-read display communicates status information.
• The user-connection terminal strip handles common jobs
with ease while providing application flexibility with extra
inputs and relays not found on other drives.
• Standard “Built-In” Dynamic Braking Resistors virtually
eliminate nuisance trips, providing more uptime.
• 60:1 constant torque turn down ratio provides low speed
performance when you need it. Optional performance with
enhanced turndown ratio using encoder feedback option.
advanced vacon x5 features
USB FUNCTIONS
PROGRAM SEQUENCER ENHANCEMENTS
• Parameter Save / Recall
• Save parameter set to USB stick and upload to another
drive
• Stored data easily opened with Microsoft Excel
• Ability to define custom file name (numbers or text)
• Easy firmware upgrades using standard USB memory
stick
• Improved functionality is closer to traditional PLC than
available with current X4
• New loop and branch capabilities available
• Real Time Clock — time-of-day (TOD) enable function,
allows programmed operation to specific periods of the day
or week
OPTIONS
REAL TIME CLOCK FUNCTION
• Control operation based on time-of-day. Separate weekday
and weekend settings available
• Fault Information — real time data is stored with all faults
• Signals an event via text on the display or contact closure,
independent of drive operation
• Keeper Function — logs time-based data from external or
internal signals
• Data read via serial communication or transferred to USB
Memory Stick
The ability to accept option boards enhances the Vacon X5’s
application flexibility.
Current options afford Vacon X5 Profibus with the opportunity
to communicate on powerful serial communication networks
like DeviceNet, Ethernet IP, Profibus and Modbus TCP/IP.
An additional option affords the opportunity to interface a
shaft mounted optical encoder to the Vacon X5 for improved
performance. All options include five (5) channels of 115Vac
control options.
Remote IP66-rated keypad are also available for both the
Vacon X4 and X5 drives.
applications
Municipal Water Supply Application — User needs to gather
information on a scheduled basis of the amount of water
that is pumped out of a municipal well. The readings must
be gathered weekly and be in thousands of gallons per
day. The Keeper function can gather this automatically
and the operator only needs to download once a week. The
information is in CSV format that will open in Excel with
defined headers.
Unattended Operation — Energy savings add up every day
with Vacon X5’s time-of-day functionality providing automated
startup of critical operating systems. Prior to the arrival of
the production team, each morning the dust collector, cooling
fans and even the lights in a foundry all start-up to full
operating status without the need for human intervention. At
the end of the day, no one needs to remember to shut these
systems down. The Vacon X5 takes care watching the clock
for you. Saving energy is just one of the benefits delivered by
the Vacon X5.
5
product range
VACON X Series 115 Vac 1-ph, NEMA 4X/IP66 Indoor and Outdoor, EMC Class C4
Product Code
Vacon X4
Vacon X5
--VACONX4C1S010C
VACONX5C1S010C
VACONX5C1S010C09
Motor Shaft Power and Current
Heavy Duty (150%)
Normal Duty (120%)
HP
kW
Amps
HP
kW
Amps
0.5
0.37
2.2
1
0.75
4.2
0.5
0.37
2.2
1
0.75
4.2
OL Amps
(1 Min/10 Min)
5
5
Frame
Size
Option Board
(Y/N)
F1A
F0
Y
N
Frame
Size
Option Board
(Y/N)
F1A
F1A
F1A
F1A
F1A
F2A
F2A
F3
F3
F0
F0
F0
F1
F1
F2
F2
F3
F3
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
N
N
N
N
N
N
N
Frame
Size
Option Board
(Y/N)
F1A
F1A
F1A
F1A
F1A
F1A
F2A
F2A
F2A
F2A
F3
F3
F4
F4
F4
F0
F0
F0
F1
F1
F1
F2
F2
F2
F2
F3
F3
F4
F4
F4
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Frame
Size
Option Board
(Y/N)
F5
F5
F5
F5
F5
F5
Y
Y
Y
N
N
N
VACON X Series 200-230 Vac 3-ph, NEMA 4X/IP66 Indoor and Outdoor, EMC Class C4
Product Code
Vacon X4
Vacon X5
------------------VACONX4C20010C
VACONX4C20020C
VACONX4C20030C
VACONX4C20050C
VACONX4C20075C
VACONX4C20100C
VACONX4C20150C
VACONX4C20200C
VACONX4C20250C
VACONX5C20010C
VACONX5C20020C
VACONX5C20030C
VACONX5C20050C
VACONX5C20075C
VACONX5C20100C
VACONX5C20150C
VACONX5C20200C
VACONX5C20250C
VACONX5C20010C09
VACONX5C20020C09
VACONX5C20030C09
VACONX5C20050C09
VACONX5C20075C09
VACONX5C20100C09
VACONX5C20150C09
-----
Motor Shaft Power and Current
Heavy Duty (150%)
Normal Duty (120%)
HP
kW
Amps
HP
kW
Amps
0.5
0.37
2.2
1
0.75
4.2
1
0.75
4.2
2
1.5
6.8
2
1.5
6.8
3
2.2
9.6
3
2.2
9.6
5
4
15.2
5
4
15.2
7.5
5.5
22
7.5
5.5
22
10
7.5
28
10
7.5
28
15
11
42
15
11
42
20
15
54
20
15
54
25
18.5
68
0.5
0.37
2.2
1
0.75
4.2
1
0.75
4.2
2
1.5
6.8
2
1.5
6.8
3
2.2
9.6
3
2.2
9.6
5
4
15.2
5
4
15.2
7.5
5.5
22
7.5
5.5
22
10
7.5
28
10
7.5
28
15
11
42
15
11
42
20
15
54
20
15
54
25
18.5
68
OL Amps
(1 Min/10 Min)
5
8.2
11.5
18.2
26
34
50
65
82
5
8.2
11.5
18.2
26
34
50
65
82
VACON X Series 380-460 Vac 3-ph, NEMA 4X/IP66 Indoor and Outdoor, EMC Class C4
Product Code
Vacon X4
Vacon X5
------------------------------VACONX4C40010C
VACONX4C40020C
VACONX4C40030C
VACONX4C40050C
VACONX4C40075C
VACONX4C40100C
VACONX4C40150C
VACONX4C40200C
VACONX4C40250C
VACONX4C40300C
VACONX4C40400C
VACONX4C40500C
VACONX4C40600C
VACONX4C40750C
VACONX4C41000C
VACONX5C40010C
VACONX5C40020C
VACONX5C40030C
VACONX5C40050C
VACONX5C40075C
VACONX5C40100C
VACONX5C40150C
VACONX5C40200C
VACONX5C40250C
VACONX5C40300C
VACONX5C40400C
VACONX5C40500C
VACONX5C40600C
VACONX5C40750C
VACONX5C41000C
VACONX5C40010C09
VACONX5C40020C09
VACONX5C40030C09
VACONX5C40050C09
VACONX5C40075C09
VACONX5C40100C09
VACONX5C40150C09
VACONX5C40200C09
VACONX5C40250C09
VACONX5C40300C09
-----------
Motor Shaft Power and Current
Heavy Duty (150%)
Normal Duty (120%)
HP
kW
Amps
HP
kW
Amps
0.5
0.37
1.1
1
0.75
2.1
1
0.75
2.1
2
1.5
3.4
2
1.5
3.4
3
2.2
4.8
3
2.2
4.8
5
4
7.6
5
4
7.6
7.5
5.5
11
7.5
5.5
11
10
7.5
14
10
7.5
14
15
11
21
15
11
21
20
15
27
20
15
27
25
18.5
34
25
18.5
34
30
22
40
30
22
40
40
30
52
40
30
52
50
37
65
50
37
65
60
45
77
60
45
77
75
55
96
75
55
96
100
75
124
0.5
0.37
1.1
1
0.75
2.1
1
0.75
2.1
2
1.5
3.4
2
1.5
3.4
3
2.2
4.8
3
2.2
4.8
5
4
7.6
5
4
7.6
7.5
5.5
11
7.5
5.5
11
10
7.5
14
10
7.5
14
15
11
21
15
11
21
20
15
27
20
15
27
25
18.5
34
25
18.5
34
30
22
40
30
22
40
40
30
52
40
30
52
50
37
65
50
37
65
60
45
77
60
45
77
75
55
96
75
55
96
100
75
124
OL Amps
(1 Min/10 Min)
2.5
4.1
5.8
9.1
13.2
16.8
25
32
41
48
63
78
92
115
149
2.5
4.1
5.8
9.1
13.2
16.8
25
32
41
48
63
78
92
115
149
VACON X Series 380-460 Vac 3-ph, NEMA 12/IP55, EMC Class C4
Product Code
6
Vacon X4
Vacon X5
------VACONX4C41250D
VACONX4C41500D
VACONX4C42000D
VACONX5C41250D
VACONX5C41500D
VACONX5C42000D
-------
Motor Shaft Power and Current
Heavy Duty (150%)
Normal Duty (120%)
HP
kW
Amps
HP
kW
Amps
100
75
124
120
90
156
125
90
156
150
110
180
150
110
180
200
132
240
100
75
124
120
90
156
125
90
156
150
110
180
150
110
180
200
132
240
OL Amps
(1 Min/10 Min)
187
216
288
187
216
288
product range
VACON X Series 575 Vac 3-ph, NEMA 4X/IP66 Indoor and Outdoor, EMC Class C4
Product Code
Vacon X4
Vacon X5
------------------------------VACONX4C50010C
VACONX4C50020C
VACONX4C50030C
VACONX4C50050C
VACONX4C50075C
VACONX4C50100C
VACONX4C50150C
VACONX4C50200C
VACONX4C50250C
VACONX4C50300C
VACONX4C50400C
VACONX4C50500C
VACONX4C50600C
VACONX4C50750C
VACONX4C51000C
VACONX5C50010C
VACONX5C50020C
VACONX5C50030C
VACONX5C50050C
VACONX5C50075C
VACONX5C50100C
VACONX5C50150C
VACONX5C50200C
VACONX5C50250C
VACONX5C50300C
VACONX5C50400C
VACONX5C50500C
VACONX5C50600C
VACONX5C50750C
VACONX5C51000C
VACONX5C50010C09
VACONX5C50020C09
VACONX5C50030C09
VACONX5C50050C09
VACONX5C50075C09
VACONX5C50100C09
VACONX5C50150C09
VACONX5C50200C09
VACONX5C50250C09
VACONX5C50300C09
-----------
Motor Shaft Power and Current
Heavy Duty (150%)
Normal Duty (120%)
HP
kW
Amps
HP
kW
Amps
0.5
0.37
0.9
1
0.75
1.7
1
0.75
1.7
2
1.5
2.7
2
1.5
2.7
3
2.2
3.9
3
2.2
3.9
5
4
6.1
5
4
6.1
7.5
5.5
9
7.5
5.5
9
10
7.5
11
10
7.5
11
15
11
17
15
11
17
20
15
22
20
15
22
25
18.5
27
25
18.5
27
30
22
32
30
22
32
40
30
41
40
30
41
50
37
52
50
37
52
60
45
62
60
45
62
75
55
77
75
55
77
100
75
99
0.5
0.37
0.9
1
0.75
1.7
1
0.75
1.7
2
1.5
2.7
2
1.5
2.7
3
2.2
3.9
3
2.2
3.9
5
4
6.1
5
4
6.1
7.5
5.5
9
7.5
5.5
9
10
7.5
11
10
7.5
11
15
11
17
15
11
17
20
15
22
20
15
22
25
18.5
27
25
18.5
27
30
22
32
30
22
32
40
30
41
40
30
41
50
37
52
50
37
52
60
45
62
60
45
62
75
55
77
75
55
77
100
75
99
OL Amps
(1 Min/10 Min)
2
3.2
4.7
7.3
10.8
13.2
20
26
32
38
49
62
74
92
119
2
3.2
4.7
7.3
10.8
13.2
20
26
32
38
49
62
74
92
119
Frame
Size
F1A
F1A
F1A
F1A
F1A
F1A
F2A
F2A
F2A
F2A
F3
F3
F4
F4
F4
F1
F1
F1
F1
F1
F1
F2
F2
F2
F2
F3
F3
F4
F4
F4
Option
Boards?
(Y/N)
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
VACON X Series 575 Vac 3-ph, NEMA 12/IP55, EMC Class C4
Product Code
Vacon X4
Vacon X5
------VACONX4C51250D
VACONX4C51500D
VACONX4C52000D
VACONX5C51250D
VACONX5C51500D
VACONX5C52000D
-------
Motor Shaft Power and Current
Heavy Duty (150%)
Normal Duty (120%)
HP
kW
Amps
HP
kW
Amps
100
75
99
120
90
125
125
90
125
150
110
144
150
110
144
200
132
192
100
75
99
120
90
125
125
90
125
150
110
144
150
110
144
200
132
192
OL Amps
(1 Min/10 Min)
150
173
230
150
173
230
Frame
Size
F5
F5
F5
F5
F5
F5
Option
Boards?
(Y/N)
Y
Y
Y
N
N
N
Vacon X4 & X5 Frame Dimensions and Weights
Frame 0
Frame 1
Frame 1A
Frame 2
Frame 2A
Frame 3
Frame 4
Frame 5
W
6,5
8,72
8,72
10,75
10,75
11,19
12,84
16,31
Dimensions (Inches) *
H
9,47
12,01
12,01
17,38
17,38
20,19
29,35
50,77
D
6,08
6,51
8,49
7,91
9,89
11,73
13,8
16,88
Weight *
(lbs)
8,5
14
14
29,5
29,5
50
95
305
W
165
221
221
273
273
286
326
414
Dimensions (mm) *
H
241
306
306
442
442
513
745
1290
D
155
166
216
201
251
314
351
429
Weight *
(kg)
3,85
6,35
6,35
13,38
13,38
22,68
43,1
138,35
*without shipping package
VACONX5 C 4 0050 C 09
type designation code
Options
09 = No Option Board Capability
Enclosure
C = NEMA 4X / IP66
D = NEMA 12 / IP55
Horsepower
(See horsepower codes table)
Input Voltage
1S = 115 Vac +/-15% Single-Phase
2 = 200-230 Vac +/-15% Three-Phase
4 = 380-460 Vac +/-15% Three-Phase
5 = 575 Vac +/-15% Three-Phase
Torque
C = Constant Torque Normal Duty
Vacon X4
Vacon X5
7
vacon x4 and vacon x5 specifications
Environmental
Operating temperature
-10°C to +40°C (14°F to 104°F)
Storage temperature
-20°C to 65°C (-4°F to 149°F)
Humidity
0% to 95% non-condensing
Altitude
1,000 m (3,300 ft) without derating
Maximum vibration
Per EN50178: Frame Size 0 and 1 5G
Acoustic noise
Cooling
80 dba sound power at 1 m (3 ft)
1 - 5 HP models: Natural convection
7.5 - 200 HP: Forced air (temperature controlled external fan)
1 – 100 HP models: NEMA 4X / IP66 Indoor or Outdoor Use
(1 – 30 HP models: 1,000 psi water spray at 6 inches)
125 – 200 HP models: NEMA 12 / IP55
UL, cUL, CE
115 Vac 1 phase, +/- 15%
1 HP
200-230 Vac, 3 phase, +/- 15%
1-25 HP
380-460 Vac, 3 phase, +/- 15%
1-200 HP
575 Vac, 3 phase, +/- 15%
1-200 HP
50 / 60 Hz +/-2 Hz
Protection Level
Agency approvals
Electrical
Input voltage
Line frequency
Source kVA (maximum)
DC bus voltage for:
Overvoltage trip
Dynamic brake activation
Normal undervoltage (UV) trip
Reference supply voltage
10 times the unit rated kVA (65kA maximum)
115 Vac models
230 Vac models
460 Vac models
814 Vdc
406 Vdc
406 Vdc
388 Vdc
388 Vdc
776 Vdc
199 Vdc
397 Vdc
199 Vdc
V/Hz or Sensorless Vector Control (SVC)
Carrier frequency = 1 to 16 kHz programmable
0 to 100% of line voltage, 3 phase
120% of rated RMS current for 60 seconds (Normal Duty rating)
150% of rated RMS current for 60 seconds (Heavy Duty rating)
Range: 0.1 – 400Hz; Stability: 0.1Hz, 0.1% analog over 24 hours +/- 10°C
3 – Analog / digital input: 0-5 / 0-10 Vdc, 0-4/20mAdc, 0-1/10/100kHz;
each includes independent calibration adjustments
10 Vdc (10 mAdc maximum)
Digital inputs (10)
Off = 0 to 3 Vdc, On = 10 to 32 Vdc (pull-up logic), selectable between pull-up and pull-down logic
Digital supply voltage
24 Vdc (150 mAdc maximum)
Preset frequencies
Analog output
X4: 8 preset frequencies; X5: 16 preset frequencies
2 SPDT relay output: 130 Vac, 1 Amp / 250 Vac, 0.5 Amp
2 open collector outputs 50 mA per device
0-10Vdc (5mA max) / 0-4/20mAdc (500 ohm load)
DC holding/injection braking
At start, stop, by frequency with adjustable current level and time or continuous DC injection by digital input
Current limit
Four-quadrant adjustable from 5 to 150%
Speed ramps
Primary and alternate adjustable from 0.1 to 3200.0 seconds
Voltage boost
Adjustable fixed boost or adjustable auto boost
Voltage characteristic
V/Hz - Linear, pump, fan or 2-piece linear; Sensorless Vector
Timed overload
Adjustable inverse time trip (shear pin, 30 sec, 60 sec, 5 minutes) for standard or inverter-duty motors
Overcurrent, Overvoltage fault, ground fault, short circuit, Dynamic Brake overload, drive temperature, power wiring
fault. Drive-timed overload, input voltage quality, overvoltage ridethrough
X4: 9-step, PLC-type functionality to control speed, direction and ramp times based on time,
analog input, digital input or pulse count.
X5: 25-step, PLC-type functionality that can control speed, direction and ramps based on time,
analog input,digital input, or pulse input. Conditional branching, addressable outputs and real time operations possible.
X4: PI Process control available with the use of a customer supplied transducer, either 0-10Vdc,
4-20mA or optical encoder input to the drive.
X5: Process control available with the use of a customer supplied transducer, either 0-10Vdc, 4-20mA or
optical encoder input to the drive. Includes an optional sleep mode, activated when the loop is satisfied.
Control system
Output voltage
Overload capacity
Frequency output
Control Features
Reference inputs
Digital outputs
Protective features
Program Sequence Controller
PI and PID Feedback
575 Vac models
1017 Vdc
970 Vdc
497 Vdc
www.vacon.com
BC00389A
Vacon Partner
Subject to changes without notice.
Download PDF