190 MAXI Series

Bussmann®
MAXI® Circuit Breakers
Series 190
Auto, Manual & Modified Reset Circuit Protectors
Dimensions
Reset Button (Series 193 only)
1.15"
(29.21)
.36"
(9.14)
.25" (6.35)
.22"
(5.59)
.89"
(22.61)
Maximum button
extension in
tripped position
.11"
(2.79)
.03"
(.76)
.67"
(17.02)
Series 190 MAXI®
Auto, Manual & Modified Reset
Circuit Protectors
Terminal Options
SPECIFICATIONS
Single Pole Thermal Type Breakers
Ratings: 8A to 50A; Series 191 & 192
12 VDC; Series 193, 194 & 195 24 VDC.
Operating Temperature: –20°F (–10°C) to 150°F (65°C).
Storage Temperature: –20°F (–10°C) to 200°F (93°C).
Applications: Trucks, RV’s, buses, boats, portable generators, welding equipment, etc.
Interchangeable Blade Terminals: with MAXI® blade fuse.
Approvals: Complies with SAE standard J553.
.50"
(12.70)
.31"
(7.87)
.42"
(10.67)
.25"
(6.35)
.84"
(21.34)
.50"
(12.70)
05 .250 QC
01 MAXI
PART NUMBERING SYSTEM
Series
Rating
1 9
❏❏❏
❏❏
191 – Auto Reset
192 – Modified Reset
193 – Manual Reset
194 – Auto Reset
195 – Modified Reset
08 – 8 amps
10 – 10 amps
15 – 15 amps
20 – 20 amps
25 – 25 amps
30 – 30 amps
35 – 35 amps**
40 – 40 amps**
50 – 50 amps**
10 AMPS & BELOW
TYPICAL CURVE
Terminal
– ❏❏
–
M – Metal*
P – Plastic
Button
Marking
❏
❏
Blank – No button
1 – Black
2 – White
Consult factory
for special markings.
* Metal cover aids heat dissipation.
Mandatory for Modified Resets.
Recommended, but not mandatory on Auto Resets.
** Only available on 01 Terminal.
15 AMPS & ABOVE
TYPICAL CURVE
10 AMPS & BELOW
TYPICAL CURVE
TEMPERATURE DERATING CURVES
15 AMPS & ABOVE
TYPICAL CURVE
TIME VS. PERCENT OF RATED CURRENT
500%
% 0F RATED CURRENT
% 0F RATED CURRENT
❏
01 – MAXI
05 – .250 Q.C.
150%
100%
50%
0%
0º
Cover
400%
300%
200%
100%
50º 77º 100º 150º
200º
250º
TEMPERATURE IN DEGREES F.
300º
0
5
10 15
20 30 40 100 200 500
TIME IN SECONDS
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this BIF document are by definition uncontrolled. This bulletin is intended to
clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any
products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
12-16-98
SB98107 Rev. A
Form No. 190 MAXI
Page 1 of 1
BIF Document: 2080
Download PDF