Cross Technologies 2016-1250 Upconverter, 140 MHz 2.50175 GHz, Fixed Owner's Manual
PDF
Download
Document
Advertisement
Advertisement
Model 2016-1250 Instruction Manual Downconverter May 2009 Rev A MODEL 2016 F=2501.750 G=+25.0 DOWNCONVERTER MENU CROSS TECHNOLOGIES INC. EXECUTE ALARM REMOTE POWER Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL [email protected] INSTRUCTION MANUAL MODEL 2016-1250 Downconverter TABLE OF CONTENTS PAGE Warranty 1.0 General 1.1 Equipment Description 1.2 Technical Characteristics 1.3 Monitor & Control Interface 2.0 Installation 2.1 Mechanical 2.2 Rear Panel Inputs & Outputs 2.3 Front Panel Controls & Indicators 2.4 Operation 2.5 Menu Settings 2.6 Use Information 2 3 3 4 5 8 8 9 10 11 12 16 WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL [email protected] 2016-1250 Manual_Rev A Page 2 5/19/09 MODEL 2016-1250 Downconverter 1.0 General 1.1 Equipment Description The 2016-1250 S-band Downconverter converts 2.50175 GHz (±36 MHz) fixed to 140 (± 36) MHz) with low group delay and flat frequency response. Synthesized local oscillators (LO) provide very low phase noise and ±0.01 ppm stability frequency selection. Multi-function push button switches select the gain, and other variable parameters. Front panel LEDs provide indication of DC power (green), PLL alarm (red), remote operation (yellow) or the TX carrier is muted (yellow). Gain is adjustable manually over a 0 to +50 dB range as adjusted by the front panel multi-function push-button switches. Remote operation allows selection of gain and other variable parameters. Parameter selection and frequency and gain settings appear on the LCD display. Connectors are Type N (female) for the RF input and BNC (female) for IF output and optional external reference input / output. The External 10 MHz reference option (option E) also includes a 10 MHz output connector, which provides the selected (internal or external) 10 MHz reference signal output. The unit is powered by a 100-240 ±10% VAC power supply, and housed in a 1 3/4” X 19 “ X 16” rack mount chassis. MODEL 2016 DOWNCONVERTER F=2501.750 G=+25.0 MENU CROSS TECHNOLOGIES INC. EXECUTE ALARM REMOTE POWER FRONT AC RF IN IF OUT GND 10 MHZ REF OUTPUT MONITOR AND CONTROL 10 MHZ EXT REF INPUT 5 4 3 2 1 9 8 7 6 J2 J1 J18 J10 J3 REAR FIGURE 1.1 Front and Rear Panels 2501.75 MHz IN 140 MHz OUT VAR ATTEN EXT 10MHz* INT 10MHz F=2501.750 G=+25.0 CONTROLLER *OPTIONAL FIGURE 1.2 Block Diagram 2016-1250 Manual_Rev A Page 3 5/19/09 1.2 Technical Characteristics TABLE 1.0 2016-1250 Downconverter Specifications* Input Characteristics Impedance/Return Loss Frequency Noise Figure, Max. Input Level range Input 1 dB compression 50 / 12 dB (see TABLE 2.2 for connector options) 2501.75 ±36 MHz, fixed 15 dB max gain -70 to -20 dBm -15 dBm Output Characteristics Impedance/Return Loss Frequency Output Level/max linear Output 1 dB compression 75 /18 dB (see TABLE 2.2 for connector options) 140 ± 36 MHZ -20/-10 dBm -5 dBm Channel Characteristics Gain Image Rejection Frequency Response Spurious Response Group Delay, max Frequency Sense 0 to 50 dB, 1 dB steps (adjustable) > 50 dB, min ±0.5 dB, 72 MHz BW, 2501.75 MHz <-60 dBC in band typ.; -55 dBC max. 0.0035 ns/MHz2 parabolic; 0.025 ns/MHz linear; 1 ns ripple Non-inverting or Inverting (selectable) Synthesizer Characteristics Frequency Accuracy Frequency Step 10 MHz level (In & Out) ±0.01 ppm max over temp internal reference NONE; fixed frequency, non-tunable 3 dBm, ± 3 dB (option E) Phase Noise @ Freq dBC/Hz Controls, Indicators Gain Selection Power Alarm Remote 100 Hz 1kHz 10kHz 100kHz 1MHz -77 -82 -90 -102 -110 direct readout LCD; pushbutton switches or remote selection Green LED Red LED Yellow LED; RS232C (RS485 option Q), 9600 baud Other RF Connector IF Connector 10 MHz Connectors Connector, Alarm, Remote Size Power Type N (female) (see TABLE 2.2 for other options) BNC (female) (see TABLE 2.2 for other options) BNC (female), 50/75 (option E) DB9 - NO or NC contact closure on Alarm 19 inch standard chassis 1.75”high X 16.0” deep 100-240 ±10% VAC, 47 - 63 Hz, 45 watts max. Options E External 10MHz Reference input and output Q RS-422/RS-485 Remote capability O LO Adjust Connector options see TABLE 2.2 *+10˚C to +40˚C; Specifications subject to change without notice 2016-1250 Manual_Rev A Page 4 5/19/09 1.3 Monitor and Control Interface A) Remote serial interface Protocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit. (RS-232C, RS-422, or RS-485 - Option-Q) M&C Cable Diagram - Cross Technologies Frequency Converters Female DB-9 PC Com Port Male DB-9 2015/16/17 M&CPort 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 Connector: Rear panel, DB-9 male J10 Pinouts (RS-232C/422/485) Pin Function 1 Rx- 2 Rx+ (RS-232C) 3 Tx+ (RS-232C) 4 Tx- 5 GND 6 Alarm Relay: Common 7 Alarm Relay: Normally Open 8 Not Used 9 Alarm Relay: Normally Closed 2016-1250 Manual_Rev A Page 5 5/19/09 B) Status Requests - Table 1.1 lists the status requests for the 2016-1250 and briefly describes them. * PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below, should be used ONLY when RS-485, (OPTION-Q), is selected. TABLE 1.1 2016-1250 Status Statu us Requests Command Syntax* Description Command Status {aaS1} Returns {S1bbbbbbbccIEA} where: • bbbbbbb = Rx frequency • cc = Rx gain • I = 1 - spectrum invert enabled • E = 1 - external 10 MHz switched in • A = summary alarm; 1=alarmed, 0=normal 10MHz Reference Offset (option O only) 2016-1250 Manual_Rev A {aaS2} Returns {S2xxxxx} where: • xxxxx = Reference offset (-2000 to +2000) Page 6 5/19/09 C) Commands - Table 1.2 lists the commands for the 2016-1250 and briefly describes them. After a command is sent the 2016-1250 sends a return “>” indicating the command has been received and executed. General Command Format - The general command format is {aaCND...}, where: { = start byte aa = address (RS-485 only - option -Q) C = 1 character, either C (command) or S (status) N = 1 character command or status request D = 1 character or more of data (depends on command) } = stop byte * PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below, should be used ONLY when RS-485, (OPTION-Q), is selected. Table 1.2 2016-1250 Commands Comm mands Command Syntax* Description Set Receiver Gain {aaC4xx} where: • xx = 2 characters • Range: 00 to 50 (0 dB to 50 dB, in 1 dB steps) Enable Spectrum Invert {aaC7x} where x =: • 0 to disable spectrum invert • 1 to enable spectrum invert Set 10MHz Reference Offset {aaC8xxxxx} where: (option O only) • xxxxx = 5 characters • Range: -2000 to +2000 Enable External 10MHz IN {aaCEx} (option -E only) where x =: • 0 to disable External 10MHz ref signal • 1 to enable External 10MHz ref signal Enable Remote Disable Remote 2016-1250 Manual_Rev A # {aaCR0} Just # sign {CR and zero} Page 7 5/19/09 2.0 Installation 2.1 Mechanical The 2016-1250 consists of one RF/Controller PCB housed in a 1 RU (1 3/4 inch high) by 16 inch deep chassis. A switching, ±12, +24, +5 VDC power supply provides power for the assemblies. The 2016-1250 can be secured to a rack using the 4 holes on the front panel. Figure 2.1 shows how the 2016-1250 is assembled. POWER SUPPLY FIGURE 2.1 2016-1250 Mechanical Assembly 2016-1250 Manual_Rev A Page 8 5/19/09 2.2 Rear Panel Input/Output Signals - Figure 2.2 shows the input and output connectors on the rear panel. AC - POWER IN AC input for switching power supply. 100-240 ±10% VAC, 47-60 Hz. J2 - RF IN 2501.75 MHz, -70 to -20 dBm input signal. Type N (female) see Table 2.2. AC J1 - IF OUT 140 MHz, -10 dBm max output signal. BNC (female) see Table 2.2. J10 - MONITOR AND CONTROL DB9 (female) - see Table 2.1 RF IN MONITOR AND CONTROL 10MHZ REF OUTPUT IF OUT GND 5 4 9 J2 J18 - 10 MHz REF OUTPUT +3 ± 3 dBm reference output. 50/75 BNC (female). 2 7 1 6 J10 J18 J1 3 8 EXT REF INPUT J3 J3 - EXT REF INPUT 3 ± 3 dBm external reference input. 50/75 BNC (female) FIGURE 2.2 Rear Panel I/Os TABLE 2.1 J10 J10 Pinouts (RS-232C/485*) Pin Function 1 Rx- 2 Rx+ (RS-232C) 3 Tx+ (RS-232C) 4 Tx- Option IF RF 5 GND STD BNC, 75 Type N, 50 6 Alarm Relay: Common -B BNC, 75 BNC, 75 7 Alarm Relay: Normally Closed -C BNC, 75 BNC, 50 TABLE 2.2 IF/RF Connector Options Optio ons 8 Not Used -D BNC, 50 BNC, 50 9 Alarm Relay: Normally Open -M BNC, 50 Type N, 50 *Remote Serial Interface Interface: DB-9 Male Protocol: RS-232C (RS-232C/422/485, option Q), 9600 baud rate, no parity, 8 data bits, 1 start bit, 1 stop bit 2016-1250 Manual_Rev A Page 9 5/19/09 2.3 Front Panel Controls and Indicators - Figure 2.3 shows the controls and indicators on the front panel. DS3 - ALARM LED Red LED indicates downconverter alarm. DS1 - REMOTE LED Yellow LED indicates remote operation. LCD DISPLAY Display shows Downconverter frequency in MHz and Gain in dB S1 - MENU/EXECUTE BUTTON Press this to get into Program mode and to execute any changes. F=2501.750 G=+25.0 MENU EXECUTE ALARM REMOTE DS6 - POWER LED Green LED indicates presence of DC power. POWER S2 - VERT. TOGGLE Vertical toggle switch that controls values in the Menu items when in program mode. Does not function in the normal display mode S3 - HORIZ. TOGGLE Horizontal toggle switch that controls which values are being adjusted. Does not function in the normal display mode FIGURE 2.3 Front Panel Controls and Indicators 2016-1250 Manual_Rev A Page 10 5/19/09 2.4 Operation 2.4.1 Installing and Operating the 2016-1250 Downconverter 1. Connect a -70 dBm to -20 dBm signal to RF IN, J2 (Figure 2.2) 2. Connect the IF OUT, J1, to the external equipment 3. Connect100-240 ±10% VAC, 47 - 63 Hz to AC on the back panel. 4. Set the gain for +00.0 to +50.0 dB (See Section 2.5 Menu Settings). 5. Be sure DS6 (green, DC Power) is on and DS3 (red, Alarm) is off (Figure 2.3). 6. AC FUSE - The fuse is a 5 mm X 20 mm, 2 amp slow blow (Type T) and is inserted in the far slot in the drawer below the AC input as shown in Figure 2.4. There is a spare fuse in the near slot. If a fuse continues to open, the power supply is most likely defective. FUSE DRAWER SPARE FUSE DRAWER AC Fuse - 2 amp slow blow (Type T), 5 mm X 20 mm INPUT ~ 100-240± 10%VAC 47-63 Hz 2A MAX FUSE TYPE T 2A GDC 250 VOLT FOR 100 - 240 V~ FIGURE 2.4 Fuse Location and Spare Fuse 2016-1250 Manual_Rev A Page 11 5/19/09 2.5 Menu Settings 2.5.1 Functions This section describes operation of the front panel controls. There are three operator switches, the LCD display and alarm indicator LEDs. All functions for the equipment are controlled by these components. The functions are (see Figure 2.5): Power Up Normal Display Menu 1 Gain (0 to +50, 1dB steps) Menu 2 Set Unit to Remote Operation Menu 3 Select Inverting or Non-inverting Spectrum Menu 4 Select External 10 MHz Ref (option E) Menu 5 10MHz Reference Frequency Offset Adjust (option O) Menu 6 Set Remote mode (option Q) Menu 7 Set RS-485 address (option Q) Save Menu When get to end of menu cycle or when “R” is selected Alarm indications appear on the LEDs (see figure 2.3). All program changes must start with the operation of the Menu/Execute switch and must also end with the operation of the Menu/Execute switch verified by the “Save Settings?” Menu. If this sequence is not followed, none of the changes will take effect. If programming is initiated and no operator action takes place for approximately 12 seconds (before the final press of the Menu/Execute switch) the display will revert to its previous status and you will need to start over. 2016-1250 Manual_Rev A Page 12 5/19/09 2.5.2 Power On Settings NOTE: THE LAST STATUS OF A UNIT IS RETAINED EVEN WHEN POWER IS REMOVED. WHEN POWER IS RESTORED, THE UNIT WILL RETURN TO IT'S PREVIOUS SETTINGS. When power is first applied, the LCD display goes through three steps. 1.The LCD goes black to show all segments are functioning. 2.The software version will be displayed. REV 1.00 3.The present frequency and gain of the downconverter is shown. F = 2501.750 G = +30 The unit is now operational and ready for any changes the operator may desire. 2.5.3 Control Switches 1. Menu/Execute - Any change to the programming of the unit must be initiated by pressing the Menu/Execute switch and completed by pressing the Menu/Execute switch. 2. Horizontal Switch - This switch is mounted so its movement is horizontal and moves the cursor left or right. 3. Vertical Switch - This switch is mounted so its movement is vertical and has two functions: a. During gain changes, the vertical movement will raise or lower the number in the direction of the arrows. b. For other functions such as Remote on/off, the vertical switch will alternately turn the function on or off regardless of the direction operated. 2016-1250 Manual_Rev A Page 13 5/19/09 2.5.4 Gain Changes When you get to this menu note that the gain changes will be made as you make them but if you do not wish to save the changes you have made, scroll to “R” and push the Menu/Execute switch and select “NO” in the “SAVE SETTINGS?” window or do not press the Menu/Execute switch; simply do nothing for approximately 12 seconds, and the system will return to the normal operating mode. To change the DOWNCONVERTER GAIN: Push the Menu/Execute switch to get to the gain setting (See Figure 2.5 for the sequence of menu options): G = +30 R Pressing the Up/Down switch will change the gain in 1 or 10 dB steps depending on the cursor location: G = +40 R By using the horizontal rocker switch the cursor can be moved left or right. Pressing the Up/Down switch will toggle the display digit selected until you have the desired gain. G = +40 R NOTE: THE GAIN WILL BE CHANGED AS YOU ADJUST THE NUMBERS. HOWEVER, THE VALUE WILL NOT BE STORED UNTIL YOU INDICATE YES IN THE SAVE SETTINGS WINDOW. When the display indicates the value desired you can push the Menu/Execute switch to get to the next item: REMOTE OFF R OR you can scroll to “R” and push the Menu/Execute switch to get to: SAVE SETTINGS? Y N Selecting Y will save the new settings. Selecting N will revert to the previous settings. Pushing the Menu/Execute switch then takes you to this: F = 2501.750 G = +40 Figure 2.5 gives the menu items and how to make changes. 2016-1250 Manual_Rev A Page 14 5/19/09 2.5.5 Alarm Indications An alarm condition for will occur if any local oscillator phase lock loop (PLL) comes out of lock. The Mute LED will light if you select Mute and the Remote LED will light when you select the Remote mode. ON POWER UP REV 1.00 Power Up NORMAL DISPLAY F = 2501.750 G = +30 Normal Display PUSH BUTTON PUSHING MENU/EXECUTE SEQUENCE Menu 1 Gain (0 to +50) R G = +30 SCROLL <> SCROLL Menu 2 Set Unit to Remote Operation REMOTE Menu 3 Select Non-Inverting or Inverting Spectrum DNSPECTRUM Menu 4 Select External 10 MHz Reference (option E) EXT REF Menu 5 Reference Offset Adjust (option O) FREQ ADJUST Offset= +0000 R Menu 6 Set Remote Mode (option Q) RS 232 R Menu 7 Set RS-485 Address (option Q) ADDRESS = 00 Save? When “R” is selected or at the end of the menu options SAVE SETTINGS? R OFF SCROLL <> SCROLL NON R R PUSH BUTTON SCROLL <> SCROLL PUSH BUTTON SCROLL <> SCROLL PUSH BUTTON SCROLL <> SCROLL R PUSH BUTTON SCROLL <> SCROLL OFF PUSH BUTTON PUSH BUTTON SCROLL <> SCROLL PUSH BUTTON SCROLL <> PUSH BUTTON Y N FIGURE 2.5 Menu Display and Sequence 2016-1250 Manual_Rev A Page 15 5/19/09 2.6 Use Information A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the user manual furnished by the manufacturer of your equipment rack. B. Mechanical Loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution. C. Elevated Operating Ambient Temperature - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack may be greater than room ambient temperature. Therefore, consideration should be given to Tmra. D. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Additional space between unit may be required. E. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring. Appropriate consideration of equipment name plate rating should be used, when addressing this concern. F. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connection to the Branch (use of power strips). G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 2016-1250 Manual_Rev A Page 16 5/19/09 CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL [email protected] 2016-1250 Manual_Rev A Page 17 5/19/09 ">
Advertisement