Allied Telesis AT-CM2K0S Software User's Guide
Allied Telesis AT-CM2K0S is a Gigabit copper-to-fiber media line card designed for use with Converteon Series chassis. It features one SFP transceiver slot and one copper twisted pair port, allowing you to establish high-speed network connections between different devices. With support for Smart MissingLink, MissingLink, and OAM modes, the AT-CM2K0S provides advanced link management and redundancy capabilities. Its compact form factor and hot-swappable design make it easy to install and maintain, ensuring minimal disruption to your network operations.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
*613-000332 Rev D*
613-000332 Rev. D
AT-CM2K0S Converteon Line Card Installation Guide
Overview
The AT-CM2K0S line card is a Gigabit copper-to-fiber media line card. You can install this line card in any Converteon Series chassis. The line card features one small form factor pluggable (SFP) transceiver slot and one copper twisted pair port. The line card is hotswappable into and out of a Converteon chassis.
Related Documents
For details on the features and functions of a Converteon chassis, refer to the relevant documents on our web site, www.alliedtelesis.com.
Verifying Package Contents
Ensure that the following items are included in your package:
One AT-CM2K0S line card
This installation guide
If any item is missing or damaged, contact your Allied Telesis sales representative for assistance.
AT-CM2K0S Line Card Components
An AT-CM2K0S line card has the components shown below.
DIP Switches
SW1
SW1
1 2 3 4
1 2 3 4
ON
ON
SFP Port LEDs
AT-CM
AT-CM
2K0
2K0
S
S
LK AT
SFP Port
SFP
SFP
Twisted Pair Port LEDs
10/100/1000-TX Twisted Pair Port
Line Card Status LEDs
T
X
T
X
LK AT
FD 1000M
LK AT
FD 1000M
RDY
RDY
10/100/10
00
10/100/10
00
SML ML O
AM 100M
SML ML O
AM 100M
536
536
Port Descriptions
SFP Port
The SFP slot supports qualified SFP transceivers with a fixed operating speed of 1000
Mbps. Another AT-CM2K0S line card must be installed with an identical SFP module in a remote chassis to de-multiplex the signals. Please refer to the AT-CM2K0S Product
Information/Related Products page on the www.alliedtelesis.com web site for the list of qualified SFP modules.
1
Twisted Pair Port
The 10/100/1000Base-TX compliant twisted pair port has an RJ-45 connector and a maximum operating distance of 100 meters (328 feet). Category 5 (5E), 100 Ohm shielded or unshielded twisted pair cabling is required. The pinouts for this port are shown in “Twisted Pair Port Pinouts.”
LEDs
An AT-CM2K0S line card has four system LEDs, two LEDs for the SFP port, and five LEDs for the twisted pair port, as described in “LED Descriptions.”
DIP Switches
One set of DIP switches allows you to set the operating mode, as described in “DIP Switch
Settings.”
Installing an AT-CM2K0S Line Card
Note
Before you install an AT-CM2K0S line card, refer to the appropriate Converteon chassis installation guide for electrical safety and emissions information.
Warning: Remove all metal jewelry, such as rings and watches, before installing or removing a line card from a powered-on chassis.
Caution: Be sure to observe all standard electrostatic (ESD) precautions, such as wearing an antistatic wrist strap, to avoid damaging the device. A line card can be damaged by static electricity
Note
You can install a Converteon line card in any Converteon chassis line card slot.
To install an AT-CM2K0S line card, perform the following procedure:
1.
Remove the AT-CM2K0S line card from its shipping package and store the package in a safe place. You must use the original package if you need to return the unit to
Allied Telesis.
2.
Configure the line card’s DIP switches as required. Refer to “DIP Switches” for more information.
3.
Select any line card slot in the chassis where you want to install the AT-CM2K0S line card, and remove the blank slot cover if one is installed.
4.
Align the back edge of the line card with the to and bottom alignment guides located inside the slot.
5.
Slide the line card into the slot until the front of the card is flush with the front of the chassis.
Note
Avoid touching the line card components.
6.
Secure the AT-CM2K0S line card to the chassis by using a Phillips screwdriver to tighten the captive screw on the faceplate.
Note
Always tighten the captive screw to secure the line card to the chassis.
7.
Repeat this procedure to install additional AT-CM2K0S line cards.
2
LED Descriptions
Status LEDs
The line card has four status LEDs as described in the following table. For more information about Smart MissingLink, MissingLink, and OAM, refer to the relevant management software user’s guide.
LED
RDY
State
Green
Off
SML
ML
Green
Off
Green
Off
OAM Green
Description
The line card has passed diagnostics.
The line card has not passed diagnostics.
The Smart MissingLink mode is enabled.
The Smart MissingLink mode is disabled.
The MissingLink mode is enabled.
The MissingLink mode is disabled.
The OAM mode is enabled (visible or bypass). You use the DIP switches to set the OAM mode, as described in “DIP Switch
Settings.”
The OAM mode is disabled.
Off
SFP Port LEDs
The SFP port has two LEDs, as described in the following table. For more information about Smart MissingLink, refer to the relevant management software user’s guide.
LED
LK
AT
State
Green
Blinking
Green
Off
Blinking
Green
Off
Description
A link has been established on the port.
While in Smart MissingLink mode, a valid connection is established on the port while a link on the other port is lost.
No link has been established on the port.
TX/RX activity has been detected on the port.
There is no TX/RX activity on the port.
Twisted Pair Port LEDs
The twisted pair port has five LEDs, as described in the following table. For more information about Smart MissingLink, refer to the relevant management software user’s guide.
LED
LK
AT
State
Green
Blinking
Green
Off
Blinking
Green
Off
FD Green
Off
1000M Green
Off
100M Green
Description
A link has been established on the port.
While in Smart MissingLink mode, a valid connection is established on the port while a link on the other port is lost.
No link has been established on the port.
TX/RX activity has been detected on the port.
There is no TX/RX activity on the port.
The port is operating in full-duplex mode.
The port is operating in half-duplex mode.
The port is operating at 1000 Mbps.
The port is not operating at 1000 Mbps.*
The port is operating at 100 Mbps.
3
LED State Description
Off The port is not operating at 100 Mbps.*
* When the 1000M and 100M LEDs are both off, the port is operating at 10 Mbps.
DIP Switch Settings
The DIP switches as described in the following table allow you to set the operating mode of the line card. For information about the operating modes as well as Smart MissingLink,
MissingLink, and OAM, refer to the relevant management software user’s guide.
Operating Mode
Link Test (default)
Smart MissingLink (SML)
MissingLink (ML)
OAM Bypass
OAM Visible
DIP 1
OFF
OFF
OFF
ON
ON
DIP 2
OFF
ON
OFF
OFF
ON
DIP 3
OFF
ON
ON
OFF
OFF
“X” means that the DIP switch position can be ON or OFF.
Twisted Pair Port Pinouts
The pinouts for the RJ-45 twisted pair port are shown in the following illustration.
X
X
X
X
X
DIP 4
3
6
1
2
1
8
8
1
The following table lists the RJ-45 pin signals when a twisted pair port is operating in the
MDI or MDI-X mode.
MDI Mode MDI-X Mode
Pin Signal Pin Signal
TX+
TX-
RX+
RX-
3
6
1
2
RX+
RX-
TX+
TX-
Warranty Information
The AT-CM2K0S line card has a limited warranty of five years. Go to www.alliedtelesis.com/warranty for the specific terms and conditions of the warranty and for warranty registration.
Specifications
Physical, Environmental, and Electrical Ratings
Dimensions (H x W x L) (2.2 cm x 7.3 cm x 13.0 cm)
.78 in. x 2.89 in. x 5.1 in.
Operating Temperature
Storage Temperature
0° C to 40° C (32° F to 104° F)
-25° C to 70° C (-13° F to 158° F)
Operating Relative Humidity
Storage Relative Humidity
5% to 90% (non-condensing)
5% to 95% (non-condensing)
Operating Altitude Range Up to 3,048 m (10,000 ft.)
Predicted MTBF (Telcordia SR332) 880,000 hours
Power Consumption 6.5 Watts maximum
4
Electrical Safety and Emissions Statements
This product meets the following standards when installed in compliant host equipment.
U.S. Federal Communications Commission
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Emissions
Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Immunity
Electrical Safety
FCC Class A, EN55022 Class A, VCCI Class A, C-TICK, CE
EN55024
UL60950 ( c
UL us
), EN60950 (TUV), CSA22.2 No. 950
5
Copyright © 2008 Allied Telesis, Inc. All rights reserved.
6
No part of this publication may be reproduced without prior written permission from Allied
Telesis, Inc.
advertisement