Baxi EcoBlue range guide

EcoBlue combi, system and heat only boilers

Range guide

Useful information

Technical helpline

0844 871 1525

Opening hours

Monday - Friday 8.00am - 6.00pm

Weekends and bank holidays 8.30am - 2.00pm

We are closed on Christmas Day and

New Year’s Day

Website baxi.co.uk

Email [email protected]

Address

Baxi

Brooks House

Coventry Road

Warwick

CV34 4LL

Introduction

A brand you can trust

Baxi make it easy

Baxi EcoBlue

+ Combi

Features and benefits

Technical specifications

What’s inside the boiler?

Flues page

2

3

Baxi EcoBlue

Advance Combi

Features and benefits

Technical specifications

What’s inside the boiler?

Flues page

10-11

12-13

14

15

Baxi EcoBlue

System

Features and benefits

Technical specifications

What’s inside the boiler?

Flues page

16-17

18-19

20

21

Baxi EcoBlue

Heat

Features and benefits

Technical specifications

What’s inside the boiler?

Flues page

22-23

24-25

26

27

Baxi EcoBlue

Advance Heat

Features and benefits

Technical specifications

What’s inside the boiler?

Flues page

28-29

30-31

32

33

Multifit Flue

Solutions page

Horizontal concentric flues 34 & 35

Plume displacement kits

Vertical concentric flues

Twin pipe flues

34

35 & 36

37

Additional services

page

How we can help 38-39 page

4-5

6-7

8

9

A brand you can trust

Baxi has been manufacturing in the UK for nearly 150 years. It has a heritage of providing cutting edge heating products for homes and is the best known boiler manufacturer amongst homeowners

.

We continue to invest in the business to provide reliable, energy efficient heating and hot water products, backed by industry-leading customer support, nationwide availability of parts and training.

A brief history of Baxi

1866

Iron moulder Richard Baxendale opens the doors of his new company

1935

An underfloor draught system for solid fuel heating is launched – the first product bearing the Baxi name

1955

Philip Baxendale, Richard’s great-grandson, becomes General Manager as Baxi becomes a household name

1963

Baxi develops a warm-air central heating technology fuelled by gas

1966

Baxi launches its most famous product: the Bermuda gas-fired back boiler

1983

Baxi is sold to its workforce, becoming the

UK’s largest employee partnership of its kind

1989

The Baxi Solo – a low-weight cast iron boiler is launched

1999

A period of acquisitions sees Baxi purchasing

Ocean Idroclima and the Blue Circle Heating Division

2001

The Baxi 105 E becomes the

UK’s biggest-selling combi boiler

2006

The award-winning Baxi

Duo-tec Combi HE is launched

2010

The UK’s first domestic, wall-hung micro-CHP appliance, Baxi Ecogen, is launched

2012

Baxi Ecogen wins the

Queen’s Award for Enterprise in Innovation

†According to independent research.

Baxi make it easy

Introducing Baxi EcoBlue

The Baxi EcoBlue range of boilers, including combi, system and heat only, has been designed with you, the installer, in mind, for reliability, easy installation and efficiency.

In fact, the final products have been based on extensive research, talking to installers all over the country.

Reliability

We have invested in state-of-the-art laboratory testing equipment and have carried out extensive field trials, so we are confident our boilers will deliver exceptional reliability. They are built using high quality Baxi Genuine Parts, which are approved under the Gas Appliance Directive to meet European legislation, to make sure your customers are safe and our boilers are reliable.

Easy to install

We have incorporated the features you told us were important to you, like a simple to fix wall mounting jig with easy access to all the boiler connections, plug-in controls that you don’t have to wire in

*

, an easily accessible gas testing point and a pressure gauge on the front of the boiler – all small things that will make your job easier.

Convenient packaging

We’ve also made the packaging more convenient – packing them upright means boilers are easier to transport, you can always tell which way is ‘up’, and when you open them, all the components can be unpacked in the order you need them.

So if you want to fit the jig and pipework, and come back later to hang the boiler, you can – easily. It’s a simple thing, but will help you save time on the job.

Energy efficiency

Your customers will be delighted too. Baxi EcoBlue boilers are extremely energy efficient, so they can help to reduce household energy bills by up to £300 a year

**

.

With a wide range of models and outputs to suit every property and every pocket,

Baxi EcoBlue boilers are stylish and compact, easy to use and with a modulation of 1:5, are economical to run.

*Except Baxi EcoBlue Heat and Baxi EcoBlue Advance Heat which do not have plug in controls.

**According to the Energy Saving Trust.

page 3

What can I say – a good boiler! It is very light, compact and only took me a couple of hours to install. Would definitely use again and recommend to others.

Gurmukh Bansal

AS Builder

Baxi EcoBlue

+ Combi

The Baxi EcoBlue + Combi is small enough to fit into a standard 300mm deep cabinet, making it particularly suitable for homes where space is at a premium. It is a powerful little boiler, delivering excellent flow rates for your customers’ comfort and convenience; plus a 5 year extended warranty

*

as standard.

Accessories

The following accessories are compatible with the Baxi EcoBlue + Combi.

5

yr

WARRANTY*

COMPACT

SIZE

PLUG-IN

CONTROLS

FRONT

ACCESS TO

COMPONENTS

FULL WALL

MOUNTING

JIG

Key features

Outputs: 24kW, 28kW and 33kW

Compact size

Baxi EcoBlue + Combi has a 5 year warranty*

Full wall mounting jig with positive fixing, easy to access boiler connections, gas test point on gas tap and integral filling loop

One metre lead included

Full range of plug-in timers

Front access to all components

Industry leading choice of flue lengths, bends and accessories

Benefits

To suit most property sizes

Fits standard 300mm deep cupboard

For extra peace of mind

Straightforward and quicker installation and commissioning

Easy to install and you don’t need access to the control box

Simple fixing into fascia saves time

Straightforward and quick servicing

For versatile siting

* Subject to registration and an annual service. Terms and conditions apply. Visit baxi.co.uk/warranty page 4

Baxi plug-in mechanical timer

Baxi plug-in digital timer

Baxi wireless mechanical RF thermostat

Baxi single channel wired programmable room thermostat

Baxi single channel wired programmer

Baxi room thermostat

Baxi wired outdoor weather sensor – combi

Multifit GasSaver

GS1c page 5

Baxi EcoBlue + Combi

Technical specifications

HOW WE MAKE IT EASY

Easy to install and you don’t need access to the control box.

A

E

D

Boiler dimensions

Width [A] Height [B] Depth [C]

390mm 700mm 295mm

Service clearances

Side [D] Upper [E]

5mm

*

175mm

*

Lower [F] Front [G]

150mm

*

5mm

* in operation,

450mm* for servicing

*

These are the minimum recommended dimensions.

Greater clearance will aid installation and maintenance.

B

D

What’s in the box?

G

F

C

EcoBlue + Combi Boiler Pre-plumbing jig

(including isolation valves)

Literature pack page 6

Fittings pack

Technical details

Baxi EcoBlue + Combi

Sales code

Controls

Concealed user controls

Operating mode selector switch with reset

Boiler only

User adjustable DHW temperature

User adjustable CH temperature

Temp/status/ fault diagnosis display

Baxi plug-in mechanical timer

Baxi plug-in digital timer

Baxi wireless mechanical RF thermostat

Baxi wired outdoor weather sensor – combi

Baxi single channel wired programmable room thermostat

Baxi single channel wired programmer

Baxi room thermostat

Gas

SEDBUK 2005 seasonal efficiency

Range – 40°C to 60°C

Range – 25°C to 80°C

Circulating pump exercise feature

Pump overrun

Integral ‘boiler only’ frost thermostat

Concentric flue system

Standard telescopic concentric flue

Horizontal concentric (60/100 mm)

Band

%

NOx class

Output CH (non condensing)

Gas supply pipe size

Inlet supply pressure (natural gas)

Maximum gas rate (nat gas after 10 mins)

Mechanical and hydraulic

Domestic hot water (DHW) kW (max) kW (min)

(mm) mbar (nominal) m 3 /hr

Maximum DHW flow rate (Delta T @ 35º max)

Minimum DHW Flow rate required

Minimum operating DHW pressure required

Maximum DHW system pressure

Safety discharge pressure

Compartment ventilation required

Flow / return pipe size

Temporary filling loop supplied

Integral expansion vessel

CH system inhibitor required

Condensate discharge pipe size

Input – kW (max) gross

Input – kW (max) net

Output – kW (max) l/min l/min bar bar bar

(mm)

Size (litres)

(mm)

Electrical

Electrical supply

Permanent live required

Electrical power cable fitted as standard

Power consumption when firing

External fuse rating

Internal fuse rating

Volts / H z

Yes / no

1m of 3 core

Watts

Amps

AH

Boiler IP rating (electrical protection) without integral timer fitted Approval category

Length in mm

Max equivalent length (m)

Reduction per 135º bend (m)

Reduction per 93º bend (m)

Max equivalent length (m) Horizontal concentric (80/125 mm)

Twin pipe flue system

Horizontal twin tube (80/80 mm) Max equivalent length

(both tubes in parallel) (m)

Reduction per 135º bend (m)

Reduction per 93º bend (m)

Weights

Installer lift weight (boiler)

Gross packaged boiler weight

Max (kg)

(kg)

Note 2 - Where low flow taps or fittings are intended to be used in DHW systems connected to Baxi combination boilers it is strongly recommended that the DHW flow rate does not fall below 2.5 l/min to ensure reliable operation.

24

7200244

27.4

24.7

24

9.8

2.0 (see note 2)

0.15

8

3.0

22

3

21.5

3

8

A

91.1

5

20

4.6

22

20

2.61

3

3

LCD display

Optional

Optional

Optional

Optional

Optional

Optional

Optional

3

3

230V / 50H z

3

3

123

3

F2L

IPX5D

3

3

3

315-500

10

0.5

1

20

15

0.25

0.5

34.0

39.2

28

7200245

3

3

LCD display

Optional

Optional

Optional

Optional

Optional

Optional

Optional

3

3

A

91.1

5

24

5.5

22

20

3.05

230V / 50H z

3

3

132

3

F2L

IPX5D

3

3

3

315-500

10

0.5

1

20

15

0.25

0.5

34.0

39.2

230V / 50H z

3

3

135

3

F2L

IPX5D

3

3

3

315-500

10

0.5

1

20

15

0.25

0.5

36.0

41.2

33

7200246

3

3

LCD display

Optional

Optional

Optional

Optional

Optional

Optional

Optional

3

3

A

91.1

5

28

6.6

22

20

3.59

page 7

What’s inside the boiler?

Baxi EcoBlue + Combi

Flue connection

Expansion vessel

Stainless steel heat exchanger

Burner

Flame sensing electrode

Spark electrode

Air/gas collector

Venturi

Igniter

Fan assembly

Pump

Condensate trap

Pressure relief valve

Gas valve

PCB housing

Optional plug-in timer housing

Diverter valve

Pressure gauge

HOW WE MAKE IT EASY

Front access to all components page 8

Flues

Horizontal concentric flues Ø 60/100mm

Multifit flue group A

Item description

1 Horizontal telescopic flue inc. low profile elbow and fixing screws

2 Horizontal telescopic flue inc. low profile elbow and fixing screws

3 1m flue extension inc. fixing screws

4 93° flue bend inc. fixing screws

5 135° flue bend inc. fixing screws (pair)

Colour

White pipe/white terminal

White pipe/black terminal

White

White

White

Specification

315mm – 500mm

315mm – 500mm

1000mm

93°

135°

Key and OD dimensions

100mm

100mm

100mm

100mm

100mm

Sales code

720599401

720598701

720648801

720648401

720647901

Plume displacement kits Ø 60/100mm

Multifit flue group A

Item description

6

7

8

Plume displacement terminal kit inc. 1m extension and brackets

Plume displacement terminal kit inc. 1m extension and brackets

Plume displacement kit extension and brackets

Vertical concentric flues Ø 60/100mm

Multifit flue group A

Item description

4

5

9

3

Vertical flue terminal

1m flue extension inc. fixing screws

93° flue bend inc. fixing screws

135° flue bend inc. fixing screws (pair)

Colour

White

Black

White

Specification

1000mm

Key and OD dimensions

60mm

60mm

60mm

Sales code

720627001

720622901

720643401

Colour

Black

White

White

White

Specification

1000mm

93°

135°

Key and OD dimensions

100mm

100mm

100mm

100mm

Sales code

5118576

720648801

720648401

720647901

1 2 3 9

6 7

8

4

5

(x2) page 9

Baxi EcoBlue

Advance Combi

From an installation point of view, I’d say it’s one of the best boilers I’ve ever fitted.

Plus, it will be a dream to maintain and service because there’s acres of room inside so the installer can see and get to everything. It really is a doddle.

Kris Hitchin,

Northwest Boilers

The Baxi EcoBlue Advance Combi has many features that make it easy to install and commission, and front access to all components for straightforward servicing and maintenance.

Householders will like its attractive finish and simple to use controls, and its proven technology will make it a reliable and energy efficient boiler for any home.

Accessories

The following accessories are compatible with the Baxi EcoBlue Advance Combi.

7

yr

WARRANTY*

FLOW RATE

UP TO

16.4

L/MIN

PLUG-IN

CONTROLS

FRONT

ACCESS TO

COMPONENTS

FULL WALL

MOUNTING

JIG

Key features

Outputs: 24kW, 28kW, 33kW, 40kW

Exceptional hot water flow rate of up to 16.4 litres per minute

Full wall mounting jig with positive fixing, easy to access boiler connections, gas test point on gas tap and integral filling loop

Full range of plug-in timers

Industry leading choice of flue lengths, bends and accessories

One metre lead included

Front access to all components

Benefits

To suit most property sizes

Increased comfort and convenience, even in bigger properties

Straightforward and quicker installation and commissioning

Simple fixing into fascia saves time

For versatile siting

Easy to install and you don’t need access to the control box

Straightforward and quick servicing

* Subject to registration and an annual service. Terms and conditions apply. Visit baxi.co.uk/warranty page 10

Baxi plug-in mechanical timer

Baxi plug-in digital timer

Baxi wireless mechanical RF thermostat

Baxi single channel wired programmable room thermostat

Baxi single channel wired programmer

Baxi room thermostat

Baxi wired outdoor weather sensor – combi

Multifit GasSaver

GS1c page 11

Baxi EcoBlue Advance Combi

Technical specifications

HOW WE MAKE IT EASY

Straightforward and quick servicing

Boiler dimensions

Width [A] Height [B] Depth [C]

450mm 763mm 345mm

Service clearances

Side [D] Upper [E]

5mm * 175mm *

Lower [F] Front [G]

150mm * 5mm * in operation,

450mm* for servicing

* These are the minimum recommended dimensions.

Greater clearance will aid installation and maintenance.

B

D

E

A

F

G

C

D

What’s in the box?

EcoBlue Advance

Combi Boiler page 12

Pre-plumbing jig

(including isolation valves)

Literature pack Fittings pack

Technical details

Baxi EcoBlue Advance Combi

Sales code

Controls

Concealed user controls

User adjustable DHW temperature

User adjustable CH temperature

Temp/status/fault diagnosis display

Baxi plug-in mechanical timer

Baxi plug-in digital timer

Baxi wireless mechanical RF thermostat

Baxi wired outdoor weather sensor – combi

Baxi single channel wired programmable room thermostat

Baxi single channel wired programmer

Baxi room thermostat

Gas

SEDBUK 2005 seasonal efficiency

NOx class

Output CH (non condensing)

Gas supply pipe size

Flow / return pipe size

Mechanical and hydraulic

Domestic hot water (DHW)

Maximum DHW flow rate (Delta T @ 35º Max)

Minimum DHW flow rate required

Minimum operating DHW pressure required

Maximum DHW system pressure

Safety discharge pressure

Compartment ventilation required

Inlet supply pressure (natural gas)

Maximum gas rate (nat gas after 10 mins)

Temporary filling loop supplied

Integral expansion vessel

CH system inhibitor required

Condensate discharge pipe size

Electrical

Electrical supply

Permanent live required

Electrical power cable fitted as standard

Power consumption when firing

External fuse rating

Internal fuse rating

Boiler IP rating (electrical protection) without integral timer fitted

Circulating pump exercise feature

Pump overrun

Integral ‘boiler only’ frost thermostat

Concentric flue system

Standard telescopic concentric flue

Horizontal concentric (60/100 mm)

Horizontal concentric (80/125 mm)

Twin pipe flue system

Horizontal twin tube (80/80 mm)

Weights

Installer lift weight

Gross packaged boiler weight

Boiler only

24

7211520

28

7211521

33

7211522

40

7211523

Band

% kW (max) kW (min)

(mm)

(mm)

Input – kW (max) gross

Input – kW (max) net

Output – kW (max) l/min l/min bar bar bar mbar (nominal) m

3

/hr

Size (litres)

(mm)

Volts / H z

1m of 3 core

Watts

Amps

AH

Approval category

Range – 40°C to 60°C

Range – 25°C to 80°C

Length in mm

Max equivalent length (m)

Reduction per 135º bend (m)

Reduction per 93º bend (m)

Max equivalent length (m)

Max equivalent length

(both tubes in parallel) (m)

Reduction per 135º bend (m)

Reduction per 93º bend (m)

Max (kg)

(kg)

3

3

3

LCD display

Optional

Optional

Optional

Optional

Optional

Optional

Optional

3

3

3

LCD display

Optional

Optional

Optional

Optional

Optional

Optional

Optional

3

3

3

LCD display

Optional

Optional

Optional

Optional

Optional

Optional

Optional

3

3

3

LCD display

Optional

Optional

Optional

Optional

Optional

Optional

Optional

A

91.1

5

20

3.4

22

22

A

91.1

5

24

3.8

22

22

A

91.1

5

28

4.7

22

22

27.4

24.7

24

32.1

28.9

28

37.7

34.0

33

45.7

41.2

40

9.8

11.5

13.5

16.4

2.0 (see note 2) 2.0 (see note 2) 2.0 (see note 2) 2.0 (see note 2)

0.15

0.15

0.15

0.15

8

3.0

8

3.0

8

3.0

8

3.0

20

2.61

20

3.05

20

3.59

20

4.35

3

8

3

8

3

10

3

10

3

21.5

3

21.5

3

21.5

3

21.5

A

91.1

5

32

7.8

22

22

230V / 50H z

3

3

120

3

F2L

IPX5D

3

3

3

230V / 50H z

3

3

130

3

F2L

IPX5D

3

3

3

230V / 50H z

3

3

135

3

F2L

IPX5D

3

3

3

230V / 50H z

3

3

175

3

F2L

IPX5D

3

3

3

315-500

10

0.5

1

20

15

0.25

0.5

36.0

42.3

315-500

10

0.5

1

20

15

0.25

0.5

36.0

42.3

315-500

10

0.5

1

20

15

0.25

0.5

38.0

44.3

315-500

10

0.5

1

20

15

0.25

0.5

39.0

45.3

Note 2 - Where low flow taps or fittings are intended to be used in DHW systems connected to Baxi combination boilers it is strongly recommended that the DHW flow rate does not fall below 2.5 l/min to ensure reliable operation.

page 13

Flue connection

Stainless steel heat exchanger

Burner

Expansion vessel

Flame sensing electrode

Spark electrode

Air/gas collector

Venturi

Igniter

Fan assembly

Pump

Condensate trap

Diverter valve

Gas valve

PCB housing

Optional plug-in timer housing

Pressure relief valve

Pressure gauge

What’s inside the boiler?

Baxi EcoBlue Advance Combi

HOW WE MAKE IT EASY

Exceptional hot water flow rate

Flues

Horizontal concentric flues Ø 60/100mm

Multifit flue group A

Item description

1 Horizontal telescopic flue inc. low profile elbow and fixing screws

2 Horizontal telescopic flue inc. low profile elbow and fixing screws

3 1m flue extension inc. fixing screws

4 93° flue bend inc. fixing screws

5 135° flue bend inc. fixing screws (pair)

Colour

White pipe/white terminal

White pipe/black terminal

White

White

White

Specification

315mm – 500mm

315mm – 500mm

1000mm

93°

135°

Key and OD dimensions

100mm

100mm

100mm

100mm

100mm

Sales code

720599401

720598701

720648801

720648401

720647901

Plume displacement kits Ø 60/100mm

Multifit flue group A

Item description

6

7

8

Plume displacement terminal kit inc. 1m extension and brackets

Plume displacement terminal kit inc. 1m extension and brackets

Plume displacement kit extension and brackets

Vertical concentric flues Ø 60/100mm

Multifit flue group A

Item description

4

5

9

3

Vertical flue terminal

1m flue extension inc. fixing screws

93° flue bend inc. fixing screws

135° flue bend inc. fixing screws (pair)

Colour

White

Black

White

Specification

1000mm

Key and OD dimensions

60mm

60mm

60mm

Sales code

720627001

720622901

720643401

Colour

Black

White

White

White

Specification

1000mm

93°

135°

Key and OD dimensions

100mm

100mm

100mm

100mm

Sales code

5118576

720648801

720648401

720647901

1 2 3 9

6 7

8

4

5

(x2) page 15 page 14

Our company has every confidence in all Baxi products especially the new products which are coming to market. Baxi listens very carefully to installers, which is really important.

Nick Walmsley,

AGS Heating & Plumbing Ltd

Baxi EcoBlue

System

The compact dimensions

**

of the Baxi EcoBlue System boiler make it perfect for discreet siting, especially when space is at a premium. It is designed for fully pumped sealed systems and can be installed with an unvented cylinder, such as the Heatrae

Sadia Megaflo Eco. For homes with a high demand for hot water, or with more than one bathroom, it will satisfy hot water requirements while also providing heating comfort.

Accessories

The following accessories are compatible with the Baxi EcoBlue System.

5

yr

WARRANTY*

COMPACT

SIZE

PLUG-IN

CONTROLS

FRONT

ACCESS TO

COMPONENTS

FULL WALL

MOUNTING

JIG

Key features

Outputs: 12kW, 15kW, 18kW, 24kW, 28kW, 32kW

Compact size**

Full wall mounting jig with positive fixing, easy to access boiler connections, gas test point on gas tap and integral filling loop

Full range of plug-in timers

Industry leading choice of flue lengths, bends and accessories

One metre lead included

Front access to all components

Benefits

Suitable for all sizes and styles of property

Will fit inside a standard 300mm deep cabinet**

Straightforward and quicker installation and commissioning

Simple fixing into fascia saves time

For versatile siting

Easy to install and you don’t need access to the control box

Straightforward and quick servicing

* Subject to registration and an annual service. Terms and conditions apply. Visit baxi.co.uk/warranty

** With the exception of the 32kW model which is a standard full size boiler. page 16

Baxi twin channel wired programmer

Baxi room thermostat Baxi wired outdoor weather sensor system

Multifit GasSaver

GS1

Baxi Solarflo solar thermal system

Megaflo Eco and

Megaflo Eco Solar hot water storage cylinders page 17

Baxi EcoBlue System

Technical specifications

HOW WE MAKE IT EASY

Suitable for all sizes and styles of property

Boiler dimensions

Height [B]

Models 12, 15,

18, 24 and 28

Model 32 only

Width [A]

390mm

450mm

700mm

763mm

Depth [C]

295mm

345mm

Service clearances

Side [D] Upper [E]

5mm

*

175mm

*

Lower [F] Front [G]

150mm

*

5mm

* in operation,

450mm* for servicing

*

These are the minimum recommended dimensions.

Greater clearance will aid installation and maintenance.

B

D

E

A

F

What’s in the box?

G

C

D

EcoBlue System

Boiler

Pre-plumbing jig

(including isolation valves)

Literature pack Fittings pack page 18

Technical details

Baxi EcoBlue System

Sales code

Controls

Concealed user controls

User adjustable CH temperature

Temp/status/ fault diagnosis display

Baxi twin channel wired programmer

Baxi room thermostat

Baxi wired outdoor weather sensor system

Gas

SEDBUK 2005 seasonal efficiency

NOx class

Input CH

Boiler only

Range – 25°C to 80°C

Band

% kW (max) gross kW (max) net kW (min) gross kW (min) net kW (max) kW (min)

(mm) mbar m 3 /hr

Output CH (non condensing)

Gas supply pipe size

Inlet supply pressure (natural gas)

Maximum gas rate (nat gas after 10 mins)

Mechanical and hydraulic

Safety discharge pressure

Bypass required

Compartment ventilation required

Flow / return pipe size

Integral expansion vessel

CH system inhibitor required

Condensate discharge pipe size

Electrical

Electrical supply

Permanent live required

Electrical power cable fitted as standard

Power consumption when firing

External fuse rating

Internal fuse rating

Boiler IP rating (electrical protection) without integral timer fitted

Circulating pump exercise feature

Pump overrun

Integral ‘boiler only’ frost thermostat

Concentric flue system

Standard telescopic concentric flue

Horizontal concentric (60/100 mm) bar

(mm)

Size (litres)

(mm)

Volts / Hz

1m of 3 core

Watts

Amps

AH

Approval category

Horizontal concentric (80/125 mm)

Twin pipe flue system

Horizontal twin tube (80/80 mm)

Length in mm

Max equivalent length (m)

Reduction per 135º bend (m)

Reduction per 93º bend (m)

Max equivalent length (m)

Max equivalent length

(both tubes in parallel) (m)

Reduction per 135º bend (m)

Reduction per 93º bend (m)

Weights

Installer lift weight

Gross packaged boiler weight

Max (kg)

(kg)

12

7211527

315-500

10

0.5

1

20

15

0.25

0.5

315-500

10

0.5

1

20

15

0.25

0.5

315-500

10

0.5

1

20

15

0.25

0.5

315-500

10

0.5

1

20

15

0.25

0.5

34.5

39.1

32

7211532

3 3 3 3 3 3

3 3 3 3 3 3

LCD display LCD display LCD display LCD display LCD display LCD display

Optional Optional Optional Optional Optional Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

230V / 50Hz 230V / 50Hz 230V / 50Hz 230V / 50Hz 230V / 50Hz 230V / 50Hz

3 3 3 3 3 3

3

108

3

F2L

IPX5D

3

108

3

F2L

IPX5D

3

125

3

F2L

IPX5D

3

123

3

F2L

IPX5D

3

137

3

F2L

IPX5D

3

140

3

F2L

IPX5D

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

315-500

10

0.5

1

20

15

0.25

0.5

3.0

22

8

3

21.5

A

91.2

5

13.3

12.0

2.7

2.4

12.0

2.3

22

20

1.27

32.5

37.1

15

7211528

3.0

22

8

3

21.5

A

91.2

5

16.6

15.0

3.4

3.1

15.0

3.0

22

20

1.58

32.5

37.1

18

7211529

3.0

22

8

3

21.5

A

91.2

5

20.0

18.0

4.0

3.6

18.0

3.5

22

20

1.90

32.5

37.1

24

7211530

3.0

22

8

3

21.5

A

91.2

5

26.6

24.0

5.2

4.7

24.0

4.6

22

20

2.54

32.5

37.1

28

7211531

3.0

22

8

3

21.5

A

91.2

5

31.1

28.0

5.9

5.3

28.0

5.1

22

20

2.96

3.0

22

10

3

21.5

A

91.2

5

35.5

32.0

7.0

6.3

32.0

6.1

22

20

3.38

37.5

43.2

315-500

10

0.5

1

20

15

0.25

0.5

page 19

What’s inside the boiler?

Baxi EcoBlue System

Flue connection

Expansion vessel

Stainless steel heat exchanger

Burner

Flame sensing electrode

Spark electrode

Air/gas collector

Venturi

Igniter

Fan assembly

Pump

Condensate trap

Pressure relief valve

PCB housing

Optional plug-in timer housing

Gas valve

Pressure gauge

HOW WE MAKE IT EASY

Front access to all components page 20

Flues

Horizontal concentric flues Ø 60/100mm

Multifit flue group A

Item description

1 Horizontal telescopic flue inc. low profile elbow and fixing screws

2 Horizontal telescopic flue inc. low profile elbow and fixing screws

3 1m flue extension inc. fixing screws

4 93° flue bend inc. fixing screws

5 135° flue bend inc. fixing screws (pair)

Colour

White pipe/white terminal

White pipe/black terminal

White

White

White

Specification

315mm – 500mm

315mm – 500mm

1000mm

93°

135°

Key and OD dimensions

100mm

100mm

100mm

100mm

100mm

Sales code

720599401

720598701

720648801

720648401

720647901

Plume displacement kits Ø 60/100mm

Multifit flue group A

Item description

6

7

8

Plume displacement terminal kit inc. 1m extension and brackets

Plume displacement terminal kit inc. 1m extension and brackets

Plume displacement kit extension and brackets

Vertical concentric flues Ø 60/100mm

Multifit flue group A

Item description

4

5

9

3

Vertical flue terminal

1m flue extension inc. fixing screws

93° flue bend inc. fixing screws

135° flue bend inc. fixing screws (pair)

Colour

White

Black

White

Specification

1000mm

Key and OD dimensions

60mm

60mm

60mm

Sales code

720627001

720622901

720643401

Colour

Black

White

White

White

Specification

1000mm

93°

135°

Key and OD dimensions

100mm

100mm

100mm

100mm

Sales code

5118576

720648801

720648401

720647901

1 2 3 9

6 7

8

4

5

(x2) page 21

I found the EcoBlue really easy to install and was surprisingly shocked how light weight it was. From an installation point of view, I would say it’s a great product and I will continue to recommend it.

Daniel Stimp

Baxi EcoBlue

Heat

The Baxi EcoBlue Heat and Baxi EcoBlue Advance Heat are, at only 19.5kg, the lightest boilers available on the UK market

**

. They have a central flue and do not need a pump overrun or permanent live, making them suitable as a replacement for old boilers.

Small enough to fit into a cupboard, the Baxi EcoBlue Heat has contemporary style that will also fit with any modern interior.

Accessories

The following accessories are compatible with the Baxi EcoBlue Heat.

2

yr

WARRANTY*

ONLY

19.5kg

POSITIVE

FIX WALL

MOUNTING

PLATE

TOP

CENTRAL

FLUE

NO

PUMP

OVERRUN

FRONT

AND SIDE

ACCESS

Key features

Outputs: 12kW, 15kW, 18kW, 21kW and 24kW

Only 19.5kg installer lift weight

Cupboard fit

Easy fit wall mounting bracket

Top central flue

Industry leading choice of flue lengths, bends and accessories

No pump overrun or permanent live required

One metre lead included

Front and side access

Benefits

Wide range of outputs to suit most requirements

The lightest boiler available in UK**

Can be installed discreetly

Robust with a positive fix and audible lock so you know it’s secure

Easy replacement for existing boilers

For versatile siting

Saves time and money during installation, and less disruption for the householder

Easy to install and you don’t need access to the control box

Servicing is easier and quicker, and no special tools are required

* Subject to registration and an annual service. Terms and conditions apply. Visit baxi.co.uk/warranty

** As at June 2014.

page 22

Baxi twin channel wired programmer

Baxi room thermostat

Baxi Solarflo Heatrae Sadia

Megaflo Eco

Solar cylinder page 23

Baxi EcoBlue Heat

Technical specifications

Boiler dimensions

Width [A] Height [B] Depth [C]

370mm 625mm 270mm

Service clearances

Side [D] Upper [E]

5mm

*

190mm

*

Lower [F] Front [G]

120mm

*

5mm

*

35mm* in

300mm deep wall cupboard in operation,

500mm* for servicing

B

D

HOW WE MAKE IT EASY

Servicing is easier and quicker, and no special tools are required

A

E

D

G

C

F

What’s in the box?

Technical details

Baxi EcoBlue Heat

Sales code

Controls

Operating mode selector switch with reset

User adjustable CH temperature

LED temp/status/fault diagnosis display

Gas

SEDBUK 2005 seasonal efficiency

NOx class

Heat output

Gas supply pipe size

Inlet supply pressure (natural gas)

Maximum gas rate

Mechanical and hydraulic

Compartment ventilation required

Flow / return pipe size

Condensate discharge pipe size

Electrical

Electrical supply

Permanent live required

Switched live

Electrical power cable fitted as standard

Power consumption

External fuse rating

Internal fuse rating

Boiler IP rating (electrical protection)

Pump overrun

Concentric flue system

Standard telescopic concentric flue

Horizontal concentric (60/100 mm)

Boiler only

Yes / no

Range – e.g. 45°C to 82°C

Yes / no

Band

%

1 - 5 kW (max) kW (min)

(mm) mbar m

3

/hr

Horizontal concentric (80/125 mm)

Twin pipe flue system

Horizontal twin tube (80/80 mm)

Weight

Installer lift weight

Gross packaged boiler weight

(mm)

(mm)

Volts / Hz

Yes / no

Yes / no

1m of 3 core

Watts

Amps

Approval category

Yes / no

Length in mm

Max equivalent length (m)

Reduction per 135º bend (m)

Reduction per 93º bend (m)

Max equivalent length (m)

Max equivalent length

(both tubes in parallel) (m)

Reduction per 135º bend (m)

Reduction per 93º bend (m)

Max (kg)

(kg)

12

7212202

15

7212203

18

7212204

21

7212205

24

7212206

A

90.2

5

13

7.5

22

20

1.42

3

3

3

A

90.2

5

16

7.5

22

20

1.75

3

3

3

A

90.1

5

19

7.5

22

20

2.07

3

3

3

A

90.1

5

21

7.5

22

20

2.29

3

3

3

315-500

6

0.5

1

12

9

0.25

0.5

19.5

21.5

22

21.50

22

21.50

22

21.50

22

21.50

22

21.50

230V / 50Hz

3

3

17

3

1.6T

IPX4D

230V / 50Hz

3

3

20

3

1.6T

IPX4D

230V / 50Hz

3

3

23

3

1.6T

IPX4D

230V / 50Hz

3

3

25

3

1.6T

IPX4D

230V / 50Hz

3

3

33

3

1.6T

IPX4D

315-500

6

0.5

1

12

9

0.25

0.5

19.5

21.5

315-500

6

0.5

1

12

9

0.25

0.5

19.5

21.5

315-500

6

0.5

1

12

9

0.25

0.5

19.5

21.5

315-500

6

0.5

1

12

9

0.25

0.5

19.5

21.5

7.5

22

20

2.73

A

90

5

25

3

3

3

EcoBlue Heat Boiler Wall bracket page 24

Literature pack Power lead Copper tail (gas connection) and fibre washer page 25

Flow and return pipes

Flue connection

Gas pressure switch

Burner

Fan assembly

PCB housing

Spark electrode

Air inlet silencer

Aluminium heat exchanger

Gas valve

Data cable

Electrical dead test point (not visible)

Condensate trap (not visible)

Drain point

Integrated HMI cover

Slide out product I.D / serial no. plate

Controls

What’s inside the boiler?

Baxi EcoBlue Heat

HOW WE MAKE IT EASY

No pump overrun or permanent live required

Flue solutions

Horizontal concentric flues Ø 60/100mm

Multifit flue group A

Item description

1 STD horizontal telescopic flue inc. low profile elbow and fixing screws

2 STD horizontal telescopic flue inc. low profile elbow and fixing screws

3 1m flue extension inc. fixing screws

4 93° flue bend inc. fixing screws

5 135° flue bend inc. fixing screws (pair)

Colour

White pipe/white terminal

White pipe/black terminal

White

White

White

Specification

315mm – 500mm

315mm – 500mm

1000mm

93°

135°

Key and OD dimensions

60/100mm

60/100mm

100mm

100mm

100mm

Sales code

720599401

720598701

720648801

720648401

720647901

Plume displacement kits Ø 60/100mm

Multifit flue group A

Item description

6

7

8

Plume displacement terminal kit inc. 1m extension and brackets

Plume displacement terminal kit inc. 1m extension and brackets

Plume displacement kit extension and brackets

Vertical concentric flues Ø 60/100mm

Multifit flue group A

Item description

4

5

9

3

Vertical flue terminal

1m flue extension inc. fixing screws

93° flue bend inc. fixing screws

135° flue bend inc. fixing screws (pair)

Colour

White

Black

White

Specification

1000mm

Key and OD dimensions

60mm

60mm

60mm

Sales code

720627001

720622901

720643401

Colour

Black

White

White

White

Specification

1000mm

93°

135°

Key and OD dimensions

100mm

100mm

100mm

100mm

Sales code

5118576

720648801

720648401

720647901

1 2 3 9

6 7

8

4

5

(x2) page 27 page 26

The rear flue option on the Baxi EcoBlue

Advance Heat made it the perfect choice when

I had to replace an old balanced flue boiler.

So light, an easy lift weight, compact and easy to use for both installer and customer.

The homeowner was very pleased.

George Drake

Installer

Baxi EcoBlue

Advance Heat

The lightweight Baxi EcoBlue Advance Heat has the option of a top or rear flue, making it a straightforward replacement for old, standard efficiency rear flue models. The rear flue option gives it a neat, attractive appearance.

Accessories

The following accessories are compatible with the Baxi EcoBlue Advance Heat.

5

yr

WARRANTY*

ONLY

19.5kg

POSITIVE

FIX WALL

MOUNTING

PLATE

REAR

FLUE

OPTION

NO

PUMP

OVERRUN

FRONT

AND SIDE

ACCESS

Key features

Outputs: 13kW, 16kW, 19kW, 25kW, 30kW

Top or rear flue option

Simple fixing of rear flue

Only 19.5kg installer lift weight

Cupboard fit

Easy fit wall mounting bracket

Industry leading choice of flue lengths, bends and accessories

No pump overrun or permanent live required

One metre lead included

Front and side access

Benefits

Models to suit most requirements

For reduced boiler footprint and improved look

For easy and fail-safe flue fixing

The lightest boiler available in UK**

Can be installed discreetly

Robust with a positive fix and audible lock so you know it’s secure

For versatile siting

Saves time and money during installation, and less disruption for the householder

Easy to install and you don’t need access to the control box

Servicing is easier and quicker, and no special tools are required

* Subject to registration and an annual service. Terms and conditions apply. Visit baxi.co.uk/warranty

** As at June 2014.

page 28

Baxi twin channel wired programmer

Baxi room thermostat

Baxi Solarflo Heatrae Sadia

Megaflo Eco

Solar cylinder page 29

Baxi EcoBlue Advance Heat

Technical specifications

Boiler dimensions

Width [A] Height [B] Depth [C]

370mm 625mm 270mm

Service clearances

Side [D] Upper [E]

5mm

*

190mm

*

35mm* if using rear flue

Lower [F] Front [G]

120mm

*

5mm

*

35mm* in

300mm deep wall cupboard in operation,

500mm* for servicing

*

These are the minimum recommended dimensions.

Greater clearance will aid installation and maintenance.

B

D

What’s in the box?

F

HOW WE MAKE IT EASY

The lightest boiler available in the UK

A

E

D

G

C

Technical details

Baxi EcoBlue Advance Heat

Sales code Boiler only

Controls

Operating mode selector switch with reset

User adjustable CH temperature

Yes / no

Range – e.g. 45°C to 82°C

LED temp/status/fault diagnosis display

Gas

SEDBUK 2005 seasonal efficiency

Yes / no

NOx class

Heat output

Band

%

1 - 5 kW (max) kW (min)

(mm) mbar m 3 /hr

Gas supply pipe size

Inlet supply pressure (natural gas)

Maximum gas rate

Mechanical and hydraulic

Compartment ventilation required

Flow / return pipe size

Condensate discharge pipe size

Electrical

Electrical supply

Permanent live required

Switched live

Electrical power cable fitted as standard

(mm)

(mm)

Volts / H z

Yes / no

Yes / no

1m of 3 core

Power consumption

External fuse rating

Internal fuse rating

Boiler IP rating (electrical protection)

Pump overrun

Concentric flue system

Standard telescopic concentric flue

Standard in-case rear telescopic concentric flue

Horizontal concentric (60/100 mm)

Watts

Amps

Approval category

Yes / no

Length in mm

Length in mm

Max equivalent length (m)

Reduction per 135º bend (m)

Reduction per 93º bend (m)

Max equivalent length (m) Horizontal concentric (80/125 mm)

Twin pipe flue system

Horizontal twin tube (80/80 mm) Max equivalent length

(both tubes in parallel) (m)

Reduction per 135º bend (m)

Reduction per 93º bend (m)

Weight

Installer lift weight

Gross packaged boiler weight

Max (kg)

(kg)

13

7212207

3

3

3

16

7212209

3

3

3

19

7212210

3

3

3

25

7212211

3

3

3

30

7212212

3

3

3

315-500

220 - 345

6

0.5

1

12

9

0.25

0.5

19.5

21.5

A

90.2

5

13

7.5

22

20

1.42

A

90.2

5

16

7.5

22

20

1.75

A

90.1

5

19

7.5

22

20

2.07

A

90.1

5

25

7.5

22

20

2.73

22

21.50

22

21.50

22

21.50

22

21.50

22

21.50

230V / 50H z

3

3

17

3

1.6T

IPX4D

230V / 50H z

3

3

20

3

1.6T

IPX4D

230V / 50H z

3

3

23

3

1.6T

IPX4D

230V / 50H z

3

3

33

3

1.6T

IPX4D

230V / 50H z

3

3

44

3

1.6T

IPX4D

30

7.5

22

20

3.27

A

90

5

315-500

220 - 345

6

0.5

1

12

9

0.25

0.5

19.5

21.5

315-500

220 - 345

6

0.5

1

12

9

0.25

0.5

19.5

21.5

315-500

220 - 345

6

0.5

1

12

9

0.25

0.5

19.5

21.5

315-500

220 - 345

6

0.5

1

12

9

0.25

0.5

19.5

21.5

EcoBlue Advance Heat

Boiler

Wall bracket page 30

Literature pack Power lead Top flue adaptor

Copper tail

(gas connection) and fibre washer page 31

Flow & return pipes

Flue blanking plate

(to be replaced by flue connector if flueing from top)

Gas pressure switch

Burner

Fan assembly

PCB housing

Spark electrode

Air inlet silencer

Aluminium heat exchanger

Gas valve

Data cable

Electrical dead test point (not visible)

Condensate trap (not visible)

Drain point

Integrated HMI cover

Slide out product I.D / serial no. plate

Controls

What’s inside the boiler?

Baxi EcoBlue Advance Heat

HOW WE MAKE IT EASY

Servicing is easier and quicker, and no special tools are required

Flues

Horizontal concentric flues Ø 60/100mm

Multifit flue group A

Item description

1 Horizontal telescopic flue inc. low profile elbow and fixing screws

2 Horizontal telescopic flue inc. low profile elbow and fixing screws

3 Horizontal telescopic in case rear flue inc. fixing screws

4 1m flue extension inc. fixing screws

5 93° flue bend inc. fixing screws

6 135° flue bend inc. fixing screws (pair)

Colour

White pipe/white terminal

White pipe/black terminal

White pipe/black terminal

White

White

White

Specification

315mm – 500mm

315mm – 500mm

220mm – 345mm

1000mm

93°

135°

Key and OD dimensions

100mm

100mm

100mm

100mm

100mm

100mm

Sales code

720599401

720598701

7210434

720648801

720648401

720647901

Plume displacement kits Ø 60/100mm

Multifit flue group A

Item description

7

8

9

Plume displacement terminal kit inc. 1m extension and brackets

Plume displacement terminal kit inc. 1m extension and brackets

Plume displacement kit extension and brackets

Vertical concentric flues Ø 60/100mm

Multifit flue group A

Item description

5

6

10

4

Vertical flue terminal

1m flue extension inc. fixing screws

93° flue bend inc. fixing screws

135° flue bend inc. fixing screws (pair)

Colour

White

Black

White

Specification

1000mm

Key and OD dimensions

60mm

60mm

60mm

Sales code

720627001

720622901

720643401

Colour

Black

White

White

White

Specification

1000mm

93°

135°

Key and OD dimensions

100mm

100mm

100mm

100mm

Sales code

5118576

720648801

720648401

720647901

1 2 3 4 10

7 8

9

5

6

(x2) page 33 page 32

Flue solutions

Multifit flue kits now come with positive screw fixings for all connections and are available in a choice of lengths to reduce the need for onsite cutting. By popular demand we offer a choice of colours for the terminals to match existing rainwater systems.

Maximum permissible equivalent flue lengths for Baxi EcoBlue combi, system boilers are:

Group A

10m

10m

Group G

20m

20m

Group H

Maximum permissible equivalent flue lengths for Baxi EcoBlue heat only boilers are:

Where inline bends are required in a flue system, the overall length must be reduced by the following amounts:

Flue type

Horizontal concentric

Vertical concentric

Horizontal twin pipe

Vertical twin pipe

Horizontal concentric

Vertical concentric

Horizontal twin pipe

Vertical twin pipe

Concentric pipes

Twin flue pipe

6m

6m

12m

12m

135° bend

93° bend

135° bend

91.5° bend

0.5m

1m

15m

15m

9m

9m

0.25m

0.50m

Horizontal concentric flues Ø 60/100mm

MULTIFIT FLUE GROUP A

10

11

12

13

14

7

8

5

6

9

15

16

Item Description (multifit) flue system

1

2

3

4

Horizontal telescopic flue inc. low profile elbow and fixing screws

Horizontal telescopic flue inc. low profile elbow and fixing screws

Horizontal telescopic flue inc. Low profile elbow and fixing screws

Horizontal telescopic in case rear flue inc. fixing screws

Flue terminal deflector

Flue terminal deflector

Flue terminal deflector

1m flue extension inc. fixing screws

0.5m flue extension inc. fixing screws

0.25m flue extension inc. fixing screws

93° flue bend inc. fixing screws

135° flue bend inc. fixing screws

135° flue bend inc. fixing screws (pair)

Offset adaptor elbow

93° low profile boiler elbow

Stainless steel terminal guard – Ø 60/100

Colour

White pipe/ white terminal

White pipe/ black terminal

White pipe/ brown terminal

White pipe/ black terminal

White

Black

Brown

White

White

White

White

White

White

White

White

S/S

Plume displacement kits Ø 60/100mm

MULTIFIT FLUE GROUP A

Item Description (multifit) flue system

17

18

19

20

21

22

23

24

Colour

Plume displacement terminal kit inc. 1m extension and brackets White

Plume displacement kit extension and brackets

Plume displacement kit bend

White

White

Plume displacement kit bend – pair White

Plume displacement terminal kit inc. 1m extension and brackets Black

Plume displacement kit extension and brackets

Plume displacement kit bend

Plume displacement kit bend – pair

Black

Black

Black page 34

Specification

315mm – 500mm

315mm – 500mm

315mm –º 500mm

1000mm

500mm

250mm

93°

135°

135°

EcoBlue Advance only

93°

Stainless steel

60mm

60mm

60mm

100mm

100mm

100mm

100mm

100mm

100mm

100mm

100mm

100mm

Key and OD dimensions

60/100mm

60/100mm

60/100mm

100mm

Sales code

720599401

720598701

720642701

7210434

720644201

5111068

720644301

720648801

720643001

720643101

720648401

720648501

720647901

720635501

720550801

720627901

Specification

1000mm

93°

135°

1000mm

93°

135°

Key and OD dimensions

60mm

60mm

60mm

60mm

60mm

60mm

60mm

60mm

Sales code

720627001

720643401

5121369

5121370

720622901

720643301

720648701

720648601

12

16

Vertical concentric flues Ø 60/100mm

MULTIFIT FLUE GROUP A

Item Description (multifit) flue system

8

9

10

11

12

25

26

27

13

28

29

Vertical ridge flue terminal

Vertical flue terminal

Roof cover plate

1m flue extension inc. fixing screws

0.5m flue extension inc. fixing screws

0.25m flue extension inc. fixing screws

93° flue bend inc. fixing screws

135° flue bend inc. fixing screws

135° flue bend (pair) inc. fixing screws

Pitched roof flashing

Flat roof flashing

Colour

Brown

Black

White

White

White

White

White

White

Specification

1000mm

500mm

250mm

93°

135°

135°

25°/50°

Key and OD dimensions

100mm

100mm

125mm

100mm

100mm

100mm

100mm

100mm

100mm

125mm

125mm

Sales code

720647101

5118576

246143

720648801

720643001

720643101

720648401

720648501

720647901

5122151

246144

1 2 3 4 5 6 7 8 9 10 11

13

(x2)

17 21

14

18 22

15

19 23

26 20 24

(x2)

27 28

25

29 page 35

40

(x2)

44

35

31

Flue solutions

Horizontal concentric flues Ø 80/125mm

MULTIFIT FLUE GROUP G

Item Description (multifit) flue system

31

32

33

34

35

Horizontal flue inc. boiler and terminal adaptors

1m flue extension

Flue bend

Flue bend (pair)

Pipe support bracket

Colour

Black

White

White

White

White

Specification

1000mm

91.5°

135°

125mm flue pipes

Key and OD dimensions

125mm

125mm

125mm

125mm

125mm

Sales code

5118580

5118584

5118588

5118597

5118610

Vertical concentric flues Ø 80/125mm

MULTIFIT FLUE GROUP G

Item Description (multifit) flue system

36

32

33

34

28

37

29

30

35

Vertical flue terminal

1m flue extension

Flue bend

Flue bend (pair)

Roof cover plate (see page 23 for image)

Flue vertical adaptor

Pitched roof flashing (see page 23 for image)

Flat roof flashing (see page 23 for image)

Pipe support brackets

Colour

Black

White

White

White

White

White

Specification

1000mm

91.5°

135°

25°/55°

125mm flue pipes

Key and OD dimensions

125mm

125mm

125mm

125mm

125mm

100/125mm

125mm

125mm

125mm

Sales code

5111078

5118584

5118588

5118597

246143

5111070

5122151

246144

5118610

32 33 34

(x2)

36 37 38 39

(x2)

41

(x2)

45

42

46

43

(x2)

47 page 36

Twin pipe flues 80/80mm

MULTIFIT FLUE GROUP N

Item Description (multifit) flue system

29

30

45

46

41

42

43

44

47

36

38

39

40

28

Vertical flue terminal

Twin pipe extension (pair inc. Brackets)

Twin pipe flue bend (pair)

Twin pipe flue bend (pair)

Roof cover plate (see page 23 for image)

Twin pipe flue horizontal terminal kit (air and exhaust)

Twin pipe flue adaptor (boiler)

Twin pipe support (pair)

Twin to concentric adaptor 80/80 - 80/125

Pitched roof flashing (see page 23 for image)

Flat roof flashing (see page 23 for image)

Pitch roof flue terminal

Pitched roof terminal adaptor kit

Single flue terminal (air only)

Colour

Black

White

White

White

Stainless steel

White

White

White

Black

White

Specification

1000mm

90°

135°

575mm

25°/50°

25°/50°

Key and OD dimensions

125mm

80mm

80mm

80mm

125mm

80mm

80/80mm

80mm

80/125mm

125mm

125mm

60mm

60-80mm

80mm

Sales code

5111078

5111087

5111072

5111086

246143

5120172

720089801

5111081

5111084

5122151

246144

720576301

5121792

5121791

Terminal position with minimum distance (mm)

A

1

B 1

C

1

D 2

E

2

F 2

G

2

Directly below an opening, air brick, opening windows etc

Above an opening, air brick, opening window etc

Horizontally to an opening, air brick, opening window etc

Below gutters, soil pipes or drain pipes

Below eaves

Below balconies or car port roof

From a vertical drain pipe or soil pipe

H 2 From an internal or external corner

I Above ground, roof or balcony level

J From a surface or boundary line facing a terminal

K From a terminal facing a terminal (Horizontal flue)

25

300

600

1200

K From a terminal facing a terminal (Vertical flue) 600

L From an opening in a carport (e.g. door, window) into the dwelling 1200

M Vertically from a terminal on the same wall

N Horizontally from a terminal on the same wall

R From adjacent wall to flue (vertical only)

S From an adjacent opening window (vertical only)

T Adjacent to windows or openings on pitched and flat roofs

U Below windows or openings on pitched roofs

1500

300

300

300

600

2000

300

300

300

25

25

25

25

1. In addition, the terminal should be no nearer than 150mm to an opening in the building fabric formed for the purpose of accommodating a built-in element such as a window frame.

2. Only ONE 25mm clearance is allowed per installation. If one of the dimensions D, E, F, G or H is 25mm then the remainder MUST be as B.S.5440-1.

Plume displacement kit

J,K

T

U

I

R

I

M

N

C

I

D

E

F

S

L

B

G

A

I

Likely flue positions requiring a flue terminal guard

H

A

F

H

A

I

J,K

IMPORTANT: If fitting a Plume Displacement

Flue Kit, the air inlet must be a minimum of 150mm from any opening windows or doors

Air inlet

Terminal assembly

300mm min

Top view rear flue

NOTE: The distance from a fanned draught appliance terminal installed parallel to a boundary may not be less than 300mm in accordance with the diagram.

Property boundary line

150mm min.

Opening window or door page 37

How we can help

Baxi Customer Support

• Expert technical helpline

• UK based customer contact centre

• Nationwide network of Gas Safe registered engineers

Baxi Genuine Parts

• Approved parts for Baxi products

• Guaranteed quality, safety and reliability

• Nationwide network of approved stockists

• Lifetime support for Baxi products

Training

• Practical, hands on training

• Free of charge product training

• A range of specialist courses

• Expert trainers, all accredited, former heating engineers

• Training centres across the UK

Visit baxi.co.uk/training

Works

Sign up to works, Baxi’s online loyalty scheme for installers. Benefits include:

• Free Gas Safe notification – save £2.20 + VAT on every registration

• Priority engineer call out and aftersales support

• Free annual service reminder sent to your customers on your behalf

• Find an Installer listing on the Baxi website to promote your business

• Great rewards – business points for every appliance you register

Visit works2gether.co.uk to find out more

Events

Visit Baxi Area Sales Managers at your local merchant for an opportunity to get your hands on the latest Baxi boilers and discuss developments in the heating industry.

For more information and to join us at a merchant local to you, visit baxievents.co.uk

Literature

You can order all the literature you need for you and your customers, including:

• Range guides

• Product brochures for consumers

• Installation instructions

• User guides

• Instructions for discontinued products

Call the Baxi literature hotline on 0844 871 1525 or contact your

Baxi Area Sales Manager.

All our literature can be downloaded from our website baxi.co.uk

0844 871 1525

Opening hours

Monday - Friday, 8.00am - 6.00pm

Weekends and bank holidays, 8.30am - 2.00pm

We are closed on Christmas Day and New Year’s Day.

Please note calls may be monitored or recorded.

baxi.co.uk

[email protected]

Baxi

Brooks House

Coventry Road

Warwick CV34 4LL

MADE

IN

BRITAIN

This brochure is printed on paper sourced from well managed forests and other controlled sources. This brochure is printed using vegetable based inks. Please recycle this brochure when you have finished with it.

Baxi policy is one of continual improvement and development. The right to change specification and appearance without prior notice is reserved. The reproduction of colours is as accurate as photographic and printing processes allow. The consumer’s statutory rights are not affected. e&oe

EcoBlueRange/Aug14

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement