Jøtul C 450 Kennebec Installation And Operating Instructions Manual


Add to my manuals
24 Pages

advertisement

Jøtul C 450 Kennebec Installation And Operating Instructions Manual | Manualzz
138344_Rev_D - C450 Kennebec 8.2.10
Jøtul C 450 Fireplace Insert
Jøtul C 450
Fireplace Insert
Installation and Operating Instructions
for the United States & Canada
Keep these instructions for future reference.
1
138344_Rev_D - C450 Kennebec 8.2.10
NOTICE:
YOU SHOULD CONSULT THE AUTHORITY
HAVING JURISDICTION IN YOUR LOCALE
(SUCH AS MUNICIPAL BUILDING
DEPARTMENT, FIRE DEPARTMENT, FIRE
PREVENTIOIN BUREAU, ETC.) BEFORE
INSTALLATION TO DETERMINE THE NEED
TO OBTAIN A PERMIT.
Accepted For Use
City of New York
Department of Buildings
MEA # 368-04-E
Jøtul North America, Inc.
2
138344_Rev_D - C450 Kennebec 8.2.10
Table of Contents
Standards and Safety Notices
Standards / Codes.........................................................4
Safety Notices................................................................ 5
Preparation .................................................................... 5
Unpacking the Firebox . .............................................. 5
Specifications
C 450 Fireplace Insert...................................................6
C 450 Surround Assembly ..........................................6
Installation
Masonry Fireplace Requirements . ........................... 7
Factory-built Fireplace Requirements ..................... 7
Chimney Height............................................................. 7
Clearance to Combustibles ........................................8
Hearth Protection ........................................................9
Chimney Connection ................................................. 10
Kennebec Surround Assembly .................................12
Tamarack Surround Assembly . ................................13
Blower Assembly ........................................................ 14
Blower Operation ........................................................15
For Your Records...
Record the following information to help your
dealer determine what you will need should
your fireplace ever require parts or service.
The serial number and manufacturing date are
located on the permanent label on the back of
the firebox. You may also wish to attach your
sales receipt to this manual for future reference.
Model: Jøtul C 450 Fireplace Insert
Serial Number:
Purchase Date:
Dealer Name;
Operation
Wood Fuel .................................................................... 16
Air Control..................................................................... 16
Starting / Maintaining the Fire.................................17
Formation of Creosote................................................17
Installed by:
Maintenance
Ash Removal................................................................. 18
Glass Care...................................................................... 18
General Maintenance................................................. 19
Gaskets........................................................................... 19
Illustrated Parts Breakdown
Parts List ................................................................ 20-21
Appendix A
Alternate Floor Protection ....................................... 22
Warranty Statement ............................................. 23
3
138344_Rev_D - C450 Kennebec 8.2.10
Installation and Operation Instructions for USA/Canada
Installation et fonctionnement pour Canada
SAFETY NOTICE: IF THIS SOLID FUEL ROOM HEATER IS NOT PROPERLY INSTALLED,
A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS
AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Avis de sécurité: Une installation non appropriée de ce poêle de chauffage risque de provoquer un incendie. Assurez votre sécurité en respectant les directives
d’installation suivantes. Consultez les autorités locales du bâtiment ou de la prévention des incendies au sujet des restrictions et exigences relatives aux
inspections d’installations dans votre région.
Tested and listed by ITS, Intertek Testing Services, Middleton, Wisconsin.
Tested to U.S. Standards: ANSI/UL 1482, Canadian Standards: CAN/ULC-S627-M93
Standards & Approvals
The Jøtul C 450 Fireplace Insert has been tested and
listed to: U.S.: ANSI/UL 1482
Canada: CAN/ULC-S628-93
Tests performed by:
ITS, Intertek Testing Services, Middleton, WI
Manufactured and distributed by:
Jøtul North America
55 Hutcherson Dr.
Gorham, ME 04036
This heater meets the U.S. Environment Protection
Agency’s Emissions limits for wood heaters manufactured and sold after July 1, 1990.
Under specific test conditions, this heater has
shown heat output at rates ranging from 10,000 to
35,000 BTU’s per hour.
THE JØTUL C 450 FIREPLACE INSERT IS ONLY LISTED
TO BURN WOOD. DO NOT BURN ANY OTHER FUELS.
READ THIS ENTIRE MANUAL BEFORE YOU INSTALL
AND USE YOUR NEW FIREPLACE INSERT.
SAVE THESE INSTRUCTIONS AND MAKE THEM
AVAILABLE TO ANYONE USING OR SERVICING THE
FIREPLACE.
4
Check Building Codes
When installing, operating and maintaining this
fireplace insert, follow the guidelines presented
in these instructions, and make them available to
anyone using or servicing the stove.
Your city, town, county or province may require a
building permit to install a solid fuel burning appliance.
In the U.S., the National Fire Protection Association’s Code, NFPA 211, Standards for Chimneys,
Fireplaces, Vents and Solid Fuel Burning Appliances,
or similar regulations, may apply to the installation
of a solid fuel burning appliance in your area. For
further information on using your heater safely,
obtain a copy of the NFPA publication “Using Coal
and Wood Stoves Safely,” NFPA No. HS-8-1974. The
address of NFPA is 470 Atlantic Ave., Boston, MA
02210.
In Canada, the guideline is established by the CSA
Standard, CAN/CSA-B365-M93, Installation Code for
Solid-Fuel-Burning Appliances and Equipment.
Always consult your local building inspector or
authority having jurisdiction to determine what
regulations apply in your area.
138344_Rev_D - C450 Kennebec 8.2.10
Safety Notices
• BURN SOLID WOOD FUEL ONLY
• DO NOT USE CHEMICALS OR FLUIDS TO
START THE FIRE. DO NOT BURN GARBAGE OR
FLAMMABLE FLUIDS.
• IF THIS ROOM HEATER IS NOT PROPERLY
INSTALLED, A HOUSE FIRE MAY RESULT. TO
REDUCE THE RISK OF FIRE, FOLLOW THE
INSTALLATION INSTRUCTIONS. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN
PROPERTY DAMAGE, BODILY INJURY, OR LOSS
OF LIFE.
• CONTACT THE LOCAL BUILDING OR FIRE
OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION REQUIREMENTS IN
YOUR AREA. WHEN NOT ADDRESSED IN THIS
MANUAL, OR BY LOCAL CODE AUTHORITIES,
INSTALLATION SPECIFICATIONS AND
REQUIREMENTS DEFER TO NFPA 211.
• DO NOT CONNECT THIS FIREPLACE TO ANY AIR
DISTRIBUTION DUCT OR SYSTEM .
• EXTREMELY HOT WHILE IN OPERATION! KEEP
CHILDREN, CLOTHING AND FURNITURE AWAY.
CONTACT WILL CAUSE SKIN BURNS.
• NEVER OPERATE THE FIREPLACE WITH A
CRACKED OR BROKEN GLASS PANEL.
• Install smoke detectors in the living areas and
bedrooms of your home. Test them regularly
and install new batteries twice annually.
When installed in the same room as the stove,
a smoke detector should be located as far
from the stove as possible to prevent it from
sounding when adding fuel to the fire.
• Avoid creating a low pressure condition in
the room where the stove is operating. Be
aware that operation of an exhaust fan or
clothes dryer can create a low pressure area
and consequently promote flow reversal
through the stove and chimney system. The
chimney and building, however, always work
together as a system - provision of outside
air, directly or indirectly to an atmospherically
vented appliance will not guaranty proper
chimney performance. Consult your local
Jøtul authorized dealer regarding specific
installation/performance issues.
Installation
Preparation
We strongly urge you to have your authorized Jøtul
dealer install your new Jøtul C 450 Fireplace Insert.
• Check with local building officials to determine what
permits may be required before installation.
• Notify your insurance company before installing this
fireplace.
Unpacking the Fireplace
All firebox components of the Jøtul C 450 Fireplace
Insert are contained within the crate on a single pallet.
The Surround Kit is contained in the same crate. As you
unpack the contents, inspect each item for damage.
Notify your dealer of any damage such as dents, cracked
glass, or broken bricks.
Contents:
•
•
•
•
Firebox Assembly - including Firebricks, 18 installed
Ashlip
Blower Housing Assembly with Switch Hardware
Stove Hardware Bag
• Fireplace Conversion Notice Plate
• Stove Tool
• Surround Assembly
Tools & Materials Required:
•
•
•
•
•
•
•
•
•
•
work gloves
safety glasses
tape measure
phillips screwdriver
tin snips
power drill
High-temperature sealant
1” (25 mm) masonry anchors or nails, two
#10 x 1/2” sheet metal screws, three
10 mm open end wrench or socket
Removing the Firebox from Pallet
1. Detach the Trim Rod from the upper front of
2.
3.
the firebox by removing the two screws that
secure it for shipping.
The Ashlip is shipped secured under the firebox shroud. Remove two M6 bolts from the
side of the shroud to pull the ashlip out from
underneath the shroud. Replace the bolts to
re-secure the shroud to the firebox.
Remove the screws that secure the pallet
brackets to the sides of the firebox and reinstall after removing the firebox from the
pallet.
5
138344_Rev_D - C450 Kennebec 8.2.10
Surround Panel
2
Jøtul C 450 Specifications
7
Performance
Firebox
Firebox
Sleeve
to Door Opening
Figure 1. Maximum Sleeve Adjustment
Fuel:20” Logs
Heat Output1:50,000 BTU/hr. (4.1 kg/hr.)
Heating Capacity2:1,100 - 1,600 sq. ft.
Overall Efficiency3: 71%
Emissions:4.4 grams/hr.
Burn Time:
4-9 hours
Optional Blower:
125 cfm.
Shipping Weight:445 lbs. (202 kg.)
1
2
3
Surround
Panel
Firebox
Sleeve
to Door
Opening
Firebox
Maximum Heat Output based on total
kilograms of dry wood burned in a one
hour period.
Heating Capacity and Maximum Burn
Time will vary depending on design of
home, climate, wood type and
operation.
Overall Efficiency is based on a burn rate
of .99 kg wood per hour.
The Jøtul C450 Fireplace Insert meets U.S.
EPA emission limits for wood heaters sold
after July 1990, and are tested and listed to
ANSI/UL 1482, and CAN/ULC S628.93. It is
intended for installation in accordance with
NFPA 211 or CAN/CSA B365.
Figure 2. Minimum Sleeve Adjustment
Figure 3. Overall Surround Dimensions are the same for both
Kennebec and Tamarack styles. (Kenebec with double-doors
shown here).
6
Figure 4. Flue Collar Centerline from Front Face
138344_Rev_D - C450 Kennebec 8.2.10
Installation
Masonry Fireplace Requirements
• The entire fireplace and chimney must be cleaned
and inspected before installation. The system
must meet local building code requirements.
• The structure and components must be free of
any defects such as cracks or broken bricks or flue
tiles. Any damage must be repaired before installation.
Any opening that may exist between the masonry
of the fireplace and the facing masonry must be
permanently sealed.
• The chimney must have a clay tile liner or a stainless steel liner utilizing a positive connection.
• DO NOT REMOVE BRICKS OR MORTAR FROM
THE FIREPLACE OR CHIMNEY STRUCTURE. However, masonry or steel may be removed from the
smoke shelf and adjacent damper frame area
to accommodate installation of a chimney liner,
provided that their removal will not weaken the
structure of the fireplace or chimney, and will not
reduce protection for combustible materials.
• CHIMNEY HEIGHT:
Minimum - 15 ft. ( 4.57 meters)
Maximum - 33 ft. (10.5 meters)
Factory-Built Fireplace Requirements
The Jøtul C450 may be installed into a factory-built
fireplace with the following conditions:
• The factory-built fireplace must be listed per
UL 127 or ULC S610.
• Installation must include a full height listed chimney liner meeting type HT requirements (2100F)
per UL 1777 (U.S.) or ULC S635 (CAN). The liner
must be securely attached to the insert flue collar
and the chimney top.
• The damper or fireplace front must be sealed to
prevent passage of room air into the the chimney
cavity.
• Circulating air chambers (i.e. in a steel fireplace
liner or metal heat circulator) may not be blocked.
• Air flow within and around the fireplace shall not
be altered by installation of the insert. The C 450
Surround Panels comply with this requirement.
• Alteration of the fireplace is limited to
a) removal of the damper for liner installation
b) removal of external, non-functional trim which
must be stored within the fireplace for replacement.
• Fireplace Conversion Notice PN 220508 must be
permanently attached to the back of the fireplace.
This metal label is included in the bag containing
this manual.
Minimum Fireplace Dimensions
A: FRONT WIDTH *...........................27 1/2” (698 mm)
• Final approval is contingent on the authority having local jurisdiction.
B: HEIGHT ............................................... 23” (584 mm)
C: REAR WIDTH ............................... 25 1/2” (648 mm)
D: REAR HEIGHT .............................. 21 1/2” (546 mm)
E: DEPTH . ................................................14” (355 mm)
*NOTE: Width dimension accommodates clearance for
Surround attachment to the front of the firebox.
Figure 5. Minimum Fireplace Dimensions
7
138344_Rev_D - C450 Kennebec 8.2.10
Clearance to Combustible Materials
• There may be no combustible materials located
anywhere within 36” (914 mm) of the front of the
fireplace insert. This precaution includes items such
as drapes or doors that could swing into the area
within 36” of the insert.
• Clearance (open space) must be maintained between the fireplace insert and combustible materials located above and to the side.
See figures 6 - 8 for minimum dimensions.
Minimum Clearances
Clearances are measured from the hearth surface,
door opening, or centerline as noted below.
A: Hearth Protection, width from centerline............ ............................................................... 20” (508 mm)
B: Hearth Protection, forward from the door opening
. ....................................................................................... ................................................................. 18” (457 mm)
C: Side Trim, 1” max. thickness, from centerline........
. .............................................................. 20 3/4” (527 mm)
D: Side Room Wall .......................... 44 1/4” (1124 mm)
E: Mantel- with no Heat Shield:
3 1/2” (90 mm)............................. 49 1/2” (1257 mm)
Figure 7. Mantel Clearances - measured from the
hearth surface to the lowest mantel surface.
F: Mantel- with no Heat Shield:
12” (304 mm) max. depth - 55 1/2” (1410 mm)
Figure 6. Clearance Diagram - No Heat Shielding
Mantel Clearance with
Optional Heat Shield 155346
Clearance may be reduced as shown in fig. 8. Maximum approved Mantel Depth is 12”.
Clearance is measured from the hearth to the bottom of the mantel as illustrated.
8
Figure 8. Mantel Clearances, with Mantel Heat Shield
155346 - measured from the hearth to the mantel.
138344_Rev_D - C450 Kennebec 8.2.10
Firebox
Sleeve
Figure 9. Sleeve adjustment results in minimum firebox
extension forward of fireplace face.
Firebox
Sleeve
Figure 10. Provide hearth protection to accommodate
maximum firebox extension forward of fireplace face.
Hearth Protection Requirements
The floor area in front of fireplace insert must be
protected from live sparks and radiant heat.
• Materials: Hearth protection must be noncombustible insulating board, having an R value of
2.92 (0.343 K-value) such as Kaowool® 2600 #15
or the equivalent mortared masonry material.
See Appendix A on page 18 for information how
to calculate the R-value of alternative materials.
Alternate protection must composed of materials
as specified by NFPA 211.
• Protected Area: 18” Deep x 40” Wide
A) Front - The protection must extend at least 18
inches (457 mm) forward from the door opening.
B) Sides - Protection must extend 20 inches
(508 mm) to both sides of the centerline of the
insert.
• Note that the firebox may extend out forward of
the fireplace face depending on where the cabinet
sleeve has been set to accommodate flue connection. Always measure hearth protection from the
final, installed position of the firebox and the door
opening. See figures 9 and 10.
9
138344_Rev_D - C450 Kennebec 8.2.10
Chimney Connection
A positive connection must be made between the fireplace insert and the chimney by one of the following
approved methods.
In the U.S:
The insert is connected to a listed stainless steel flexible
connector that extends beyond the chimney flue tile
liner. A sealed block-off plate must be installed at the
damper area of the existing fireplace. See fig. 11.
For internal chimneys, (no sides of the chimney
exposed to the outside below the roofline,) a positive
connection to the first flue tile is acceptable provided the
tile is no larger than 8” x 12”. For external chimneys, (one
or more sides are exposed to the outside below the roof
line,) a positive connection to the first flue tile is acceptable provided the tile is no larger than 8” x 8”.
A 6”, 7”, or 9” stainless steel liner, extending the full
height of the chimney, is required for all installations
where the flue tile is greater than 8” x 12” for internal
chimneys, or 9” x 8” for external chimneys.
Installation
1. Remove the existing damper and linkage components from the fireplace. Alternatively, you can
wire the damper plate to lock it in the open position. Thoroughly clean the firebox and smoke shelf
area with a wire brush.
2. If the fireplace has been modified to accommodate installation, use anchors or masonry nails to
attach the metal Fireplace Conversion Notice Plate
(PN 220508) to the back wall of the masonry fireplace firebox where it will be readily seen should
the insert be removed.
3. Install the Flex Connection plate according to the
manufacturer’s instructions. The sealing plate may
require trimming to accommodate your specific
fireplace damper.
In Canada:
The insert must be installed with a continuous chimney
liner of 6” (152 mm) diameter extending from the fireplace insert to the top of the chimney. The chimney liner
must conform to the Class 3 requirements of CAN/ULCS635, Standard for Lining Systems for Existing Masonry
or Factory-Built Chimneys and Vents, or CAN/ULC-S640,
Standard for Lining Systems for New Masonry Chimneys.
See fig. 11a.
Flex Connector
Pipe extends into
the flue tile
Do not use aluminum or galvanized steel pipe for chimney connection components - these materials are not
suitable for use with solid fuel.
Flex
Connector
Adjustable
Sealing Plate
Damper
Frame
Locking
Bracket
Figure 11. Positive Chimney Connection - U.S.
10
Attach Fireplace
Conversion
Notice Plate
to Rear Wall of
Fireplace
138344_Rev_D - C450 Kennebec 8.2.10
Installing the Firebox
1. If appropriate, use 3” flexible noncombustible
duct to connect an outside air inlet to the air inlet
collar at the back of the firebox.
2. With assistance, move the firebox into position
within the fireplace and align the insert flue collar
with the Adaptor Collar.
3. Attach the flue connector pipe. Use a 1/8” bit to
drill attachment holes into connector pipe at the
three pilot hole locations in the firebox flue collar.
Secure the flue connector pipe using three,
#10 x 1/2” sheet metal screws.
4. Adjust the position of the Firebox to ensure that
the Surround Panel Hangers are flush with, or
slightly proud of, the outside face of the fireplace.
If the Hangers are set back from the face, you will
be unable to engage the Surround Hanger Clips
with the holes in the Hangers.
Masonry or Listed
HT Prefabricated
Chimney Cap
Sealed connection to chimney
cap
Damper linkage
removed and
plate is removed
or locked open
Attach
Fireplace
Conversion
Notice Plate
to Rear Wall
of Fireplace
Figure 11a. Positive Chimney Connection - Canada.
11
138344_Rev_D - C450 Kennebec 8.2.10
Left Breastplate
Tools Required:
• 10 mm socket or wrench
Right Breastplate
M6 x 12 Flange Bolt
M6 x 10 Flange Bolt
Right Leg
Set Screw
M6 x 12 Flange Bolt
H
M6 x 10 Flange Bolt
Left Leg
Trim Rod
M6 x 10 Flange Bolts
Hang Tab
should point
straight down
Figure 12. Kennebec Classic Surround Panel Assembly
Kennebec Surround Assembly
All fasteners have already been installed in the appropriate locations at the factory. You will need to remove
them, attach the parts together as described below and
re-install the fasteners at those locations.
1. Layout the parts. Place the castings face down on a
protective surface such as carpeting, blankets or a
sheet of cardboard. See fig. 12, page 12.
2. Attach the Breastplates to each other.
Use a 10 mm socket or wrench with two M6 x 10 hex
head flange bolts.
3. Attach the Leg plates. The Legs must be oriented with
the Hang Tabs on the inside edges as shown in fig. 12.
Use the two remaining M6 x 12 hex head flange bolts
to attach the Legs to the Breastplate assembly. See Fig.
12.
4. Install the Trim Rod, using the two M6 x 10 bolts
located on the Right and Left Legs.
5. Optional: Install the Wide Surround. If you will be
installing the optional Wide Surround Panels, use the
instructions included with that kit.
12
6. Optional: Install Mantel Heat Shield 155833.
If you will be installing the optional Mantel Heat
Shield, use the instructions included with that kit.
7. Attach the Assembly to the Firebox. Lift the entire
assembly upright and position it in front of the insert
firebox. DO NOT LIFT THE ASSEMBLY BY THE TRIM ROD.
The four Hang Tabs on the surround legs must engage
with the adjacent holes in the two brackets on either
side of the firebox opening. The surround will easily
engage with these brackets if the firebox is slightly
proud of the fireplace opening.
Hang the surround assembly on the firebox and push
the entire unit into position so that the surround is
flush against the fireplace face.
Final leg panel alignment can be adjusted by slightly
loosening or tightening those attachment bolts as
necessary.
138344_Rev_D - C450 Kennebec 8.2.10
M6x16 Hex Head Bolts
Tools Required:
• 10 mm socket or wrench
Grille Shade
Center Breastplate
Right Breastplate
Trim Rod
Right Leg
Left
Breastplate
Hang Tab
should point
straight down
Left Leg
Figure 12a. Tamarack Lattice Surround Panel Assembly
Tamarack Surround Assembly
All fasteners have already been installed in the appropriate locations at the factory. You will need to remove
them, attach the parts together as described below and
re-install the fasteners at those locations.
1. Layout the parts. Place the castings face down on a
protective surface such as carpeting, blankets or a
sheet of cardboard. See fig. 12a, above.
2. Attach the optional Grille Shade (if desired), and
Breastplates.
• Align the Center Breastplate bolt holes with the
Right and Left Breastplates.
• Place the Grille Shade in position, painted side out,
and secure the whole assembly with four M6 x 16 hex
head flange bolts, at the same locations from where
they were removed.
3. Attach the Leg plates. The Legs must be oriented with
the Hang Tabs on the inside edges as shown in fig. 12a.
Use the four remaining M6 x 16 hex head flange bolts
to attach the Legs to the Breastplates.
5. Optional: Install the Wide Surround. If you will be
installing the optional Wide Surround Panels, use the
instructions included with that kit. The mounting
bolts are already installed on the inner surround legs.
6. Attach the Assembly to the Firebox. Lift the entire
assembly upright and position it in front of the insert
firebox. DO NOT LIFT THE ASSEMBLY BY THE TRIM ROD.
The four Hang Tabs on the surround legs must engage
with the adjacent holes in the two brackets on either
side of the firebox opening. The surround will easily
engage with these brackets if the firebox is slightly
proud of the fireplace opening.
Hang the surround assembly on the firebox and push
the entire unit into position so that the surround is
flush against the fireplace face.
Final leg panel alignment can be adjusted by slightly
loosening or tightening those attachment bolts as
necessary.
4. Install the Trim Rod, using the two M6 x 16 bolts at
those locations.
13
138344_Rev_D - C450 Kennebec 8.2.10
1
Hardware Bag Contents:
6
3
2
1. Power Switch
2. Power Cord Receptacle
3. Snapstat Extension Assembly
4. Air Deflector
5. #8 x 1/2” sheet metal screws, 4
6. Ground jumper wire
7. Power Cord
7
B
4
5
ud
hro
er S
low
Tools Required:
• safety gloves and goggles
• 10 mm wrench or long socket
• 1/4” nut driver
• flat head screwdriver
• small pliers
M6 Flange Nuts
Figure 13. Blower hardware contents and assembly.
Blower Assembly
The blower is fully assembled, except for the wire
harness switch connections which depend on what
side you wish the power cord to be routed.
1. Remove the Blower Shroud to provide access to
the wire harness. Use a 10 mm socket or wrench
to remove the three M6 flange nuts that secure
the shroud to the base. See fig. 13.
2. Insert Switch and Receptacle: Determine on
which side of the ash lip extension you wish to
install the power cord and switch. The snapstat
must also be installed on that side. Use a flat
head screwdriver and pliers to pry the knockouts
from that ashlip support. Work from the inside,
to avoid marring the outside surface. Insert the
Power Switch in the upper hole, and the Power
Cord Receptacle into the lower hole. See fig. 14.
3. Install Snapstat Extension Assembly: Remove the
snapstat knock-out from the appropriate side
of the Blower Shroud. Run the snapstat leads
through the hole and attach the bracket to the
Shroud using two #8 x 1/2” sheet metal screws.
See fig. 13.
4. Attach the Air Deflector: Using the two remaining
#8 sheet metal screws, attach the Air Deflector
to the Blower Shroud on the same side as the
snapstat is installed. See fig. 13, parts 4 and 5.
5. Connect the wire leads: Follow the diagram
as shown in fig. 15. Connect the loose wires as
follows:
Green: Remove an M6 nut from the corner post
and attach the ring terminals of the two ground
leads to that post. Attach the jumper lead to the
middle Power Receptacle terminal.
White: Wire harness to upper Power Receptacle.
Black: Wire harness to lower Switch terminal
Red: Wire harness to upper Switch terminal
Brown: • Snapstat to middle Switch terminal
• Snapstat to lower Power Receptacle
14
Knock-out
Ashlip
Extension
Support
Switch
Power
Receptacle
Figure 14.
Remove knock-outs and install inserts.
Switch
BR
HI
OFF
LO
R
BR
B
W
G
BR
Power
Receptacle
G
Blower Wire
Harness
Figure 15. Wiring configuration.
Ground
Post
G
Color Key
BR-Brown
R- Red
B- Black
W- White
G- Green
8. Tuck the sheathed wire harness under the cutout at
the bottom of the Air Deflector.
9. Reattach the Blower Shroud to the Extension Base
using the three M6 x 12 flange head nuts
10. After attaching the Ashlip Extension / Blower Assembly to the fireplace (see below), plug the power
cord into the receptacle and run the cord to the
nearest house current outlet.
138344_Rev_D - C450 Kennebec 8.2.10
Install the Ashlip Extension
Assembly
The assembly is comprised of a steel Extension Base
and a cast iron Ashlip plate. The procedure is the
same for double door and single door fireboxes.
1. Engage the three spring clips on the Extension
Base with the adjoining cutouts on the firebox
base. Align the clips with these slots and push the
Extension to snap it together with the base of the
firebox base. The clips should slide over the front
edge of the bottom plate to engage with the
cutouts. See fig. 16.
2. The Ashlip plate simply rests on the Extension
Base. Engage the plate under the front doors.
Blower Operation
The two-speed blower will enhance heat circulation
around the firebox and out into the room. The blower is controlled by a heat activated switch (snapstat)
that will ONLY function when the control switch is in
either the HI or LOW setting. After the fire has been
burning for a time, the snapstat will react to the
heat and activate the blower, if the switch is in the
HI or LOW position. Conversely, the blower will continue to operate until the snapstat cools as the fire
wanes. The blower will then shut off automatically.
For best performance, do not turn the switch on
until after the fire is well-established.
If the blower is not needed, place the blower
control switch in the OFF position.
Figure 16. Attach the Ashlip Extenstion to the Firebox
base. Be sure that the clips slide OVER the front edge
of the bottom plate, not under it.
3. Plug the power cord into place.
Figure 17. Blower Wiring Diagram
THIS BLOWER MUST BE ELECTRICALLY
GROUNDED IN ACCORDANCE WITH LOCAL
CODES OR, IN THE ABSENCE OF LOCAL
CODES, WITH THE CURRENT ANSI/NFPA 70,
NATIONAL ELECTRICAL CODE OR CSA C22.1CANADIAN ELECTRICAL CODE.
THIS UNIT IS SUPPLIED WITH A THREEPRONG (GROUNDING) PLUG FOR PROTECTION AGAINST SHOCK HAZARD AND
SHOULD BE PLUGGED DIRECTLY INTO A
PROPERLY GROUNDED THREE-PRONG
RECEPTACLE. DO NOT CUT OR REMOVE THE
GROUNDING PRONG FROM THE PLUG.
ALWAYS DISCONNECT THE POWER SUPPLY
WHEN PERFORMING ANY SERVICE ON THE
FIREPLACE INSERT.
15
138344_Rev_D - C450 Kennebec 8.2.10
Operation
Read the following section carefully before building a fire
in your Jøtul C 450 Fireplace Insert.
Fuel
This stove is designed to burn natural wood ONLY. Wood
that has been air-dried for a period of 6 to 14 months will
provide the cleanest most efficient heat. Frequent use
of green or inadequately seasoned wood is conducive to
creosote accumulation and generally poor performance.
DO NOT BURN...
•Coal
•Treated or painted wood
•Cardboard
•Colored paper
•Garbage
•Solvents
WARNING:
OPERATE THIS FIREPLACE INSERT ONLY WITH
THE FRONT DOOR(S) FULLY CLOSED. A PARTIALLY
OPENED DOOR MAY RESULT IN OVER-FIRING. ALSO,
IF DOORS ARE LEFT PARTLY OPEN, GAS AND FLAME
MAY BE DRAWN OUT OF THE DOOR OPENING,
CREATING RISKS FROM BOTH FIRE AND SMOKE.
•Chemical Chimney cleaners
•Any synthetic fuel or logs
The burning of any of these materials can result in the
release of toxic fumes. NEVER USE GASOLINE, GASOLINETYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER
FLUID, OR SIMILAR LIQUIDS TO START OR “FRESHEN-UP”
THE FIRE. Always keep such liquids away from the heater
at all times.
WARNING
NEVER ALLOW LOGS TO REST DIRECTLY ON
THE GLASS. THE LOGS SHOULD ALWAYS BE
SPACED AT LEAST ONE INCH FROM THE GLASS
TO ALLOW FOR PROPER AIR FLOW WITHIN THE
STOVE.
Figure 18. Air Flow Diagram.
Air Control
A single lever regulates the Primary Air flow that controls
the intensity of the fire and consequent heat output and
burn time. This lever is located on the front of the stove
directly above the ashlip.
When first starting or reviving the fire, the control
lever should be set at the far right position to allow the
maximum amount of air into the stove. See fig. 19. After
the fire is well-established, the lever should be set at position to moderate incoming air to maintain the desired
long term heat output and/or burn time.
In general, the more air made available to the fuel
will result in the hottest fire intensity and the fastest fuel
consumption. Alternatively, the less air made available to
the firebox will result in low heat output and slow fuel
consumption.
16
CLOSED
Figure 19. Air Control Setting
OPEN
138344_Rev_D - C450 Kennebec 8.2.10
Starting and Maintaining a Fire
Burn only solid wood directly on the firebrick of the
stove. Do not elevate the fire in any way.
1. Set the Air Control Lever in the full open position. 2.
Crumple several sheets of newspaper directly on the
firebrick.
2. Place several pieces of small dry kindling (approximately 1” in diameter) on top of the newspaper, with two to
three small logs (approximately 2” to 3” in diameter)
on top.
3. Light the fire and close the door. Gradually build the
fire by adding larger and larger logs as the fire develops a bed of coals.
4. When you have added the final logs, adjust the Air
Control Lever to provide the desired fire intensity.
Experiment with a variety of air control settings to
determine the best one for your individual circumstances. Remember that fuel characteristics, chimney system
condition, building design, and weather conditions all affect the performance of your fireplace insert. In time, you
will discover how these elements combine and how you
can work with them to achieve satisfactory performance.
NEVER OVER-FIRE THE STOVE. IF ANY PART OF
THE STOVE OR CHIMNEY GLOWS, YOU ARE OVERFIRING. A HOUSE FIRE OR SERIOUS DAMAGE TO
THE STOVE OR CHIMNEY COULD RESULT. IF THIS
CONDITION OCCURS, IMMEDIATELY CLOSE THE AIR
CONTROL.
Creosote Formation
The Jøtul C 450 is designed to burn wood cleanly
and efficiently when operated as described in this
manual. However, when wood is burned slowly and
at low temperatures, tar and other organic vapors
are produced which condense on the relatively cooler
chimney flue surfaces to form creosote. Failure to
keep the chimney system free of creosote build up
could result in a chimney fire.
The creosote that accumulates in the chimney
is highly flammable and is the fuel of chimney fires.
To prevent chimney fires, it is important to have the
chimney flue and connector pipe inspected twice
monthly during frequent use and cleaned whenever
accumulation of 1/4” or more is evident. A qualified
chimney sweep or other authorized service person
can provide this service.
It is also important to remember that chimney
size, temperature and height all affect draft which in
turn affects the formation of creosote. An exterior
chimney, whether masonry or prefabricated steel,
will be exposed to cold outside temperatures, and
consequently, will be more prone to creosote accumulation than an interior flue.
A chimney flue located within the home interior
will benefit from the insulating characteristics of the
building itself. Consequently, the flue system will be
less conducive to condensation of unburned gases
and minimal creosote accumulation will result.
When reloading the stove while a bed of hot embers
still exists, follow this reloading procedure:
As a general rule, try to avoid burning the insert
at the lowest air control settings. Although a low
setting will prolong burn time, it may also result in
incomplete combustion. In reducing the fire intensity, draft is weakened and the chimney flue cools. This,
together with the increase in unburned gases, leads
to rapid creosote accumulation.
• Push the Air Control Lever to the full open position
(far right).
Break-in Period Ventilation
Adding Fuel to the Fire
• Always wear stove gloves when tending to the fire.
• Wait a few seconds before opening the door. This
allows the renewed air circulation to clear unburned
gases from the firebox.
• Use a stove tool or poker to distribute the hot embers equally around the firebox.
• Load the fuel, usually with smaller logs first.
It is normal for a new stove to emit odor and possibly
smoke during the first few fires. This is characteristic
of the burn-off of residues from the manufacturing
process and the curing of painted surfaces. Open a
window near the fireplace insert to provide plenty of
fresh air to the room during this “seasoning” period.
• Close the doors and secure the latch.
• Wait 5 – 10 minutes for the fire to re-establish before
adjusting the Air Control Lever for the desired heat
output. If a thick bed of live coals is present, you may
be able to add fuel and immediately set the air control without waiting for the fire to be re-established.
17
138344_Rev_D - C450 Kennebec 8.2.10
Maintenance
Glass Removal
Ash Removal
Always wear stove gloves when handling ashes.
Ash removal will be required periodically depending on
how frequently the stove is used. Use a steel ash shovel
and metal container with a tight-fitting lid. NEVER USE A
PAPER OR PLASTIC BAG AS AN ASH RECEPTACLE.
The container of ashes should be placed on a noncombustible floor or on the ground, well away from all
combustible materials, pending final disposal. If the
ashes are disposed of by burial in soil or otherwise dispersed, they should be kept in the closed container until
all coals and cinders have thoroughly cooled.
Glass Care
Always operate the doors slowly and cautiously to
avoid cracking or breaking the glass. Never use the
door to push wood into the firebox. If the glass
becomes cracked or broken follow the replacement
procedure below.
IMPORTANT:
REPLACE GLASS ONLY WITH JØTUL CERAMIC
GLASS SPECIFICALLY DESIGNED FOR THE
JØTUL C 450 FIREPLACE INSERT:
PART #220356 (TWO) - FOR DOUBLE DOORS
PART #222991 - FOR THE SINGLE DOOR DO
NOT USE SUBSTITUTES. REPLACEMENT
GLASS PANELS CAN BE ORDERED THROUGH
YOUR JØTUL DEALER.
NEVER OPERATE THE STOVE WITH A
CRACKED OR BROKEN GLASS PANEL.
1. Remove the door from the stove and place on a flat
surface.
Cleaning
Occasionally it will be necessary to clean the carbon
deposits and fly ash off of the glass. If deposits are allowed to remain on the glass for an extended period of
time, the glass may become etched and cloudy.
Creosote deposits should burn off during the next hot
fire.
1. The Glass must be COMPLETELY COOL.
2. Only use a cleaner that is specifically designed for
this purpose. DO NOT USE ABRASIVE CLEANING
AGENTS, OR THOSE CONTAINING AMMONIA. The use
of abrasives will damage the glass, leaving a frosted
surface. Ammonia will etch the glass to the same
effect. Crumpled newspaper is an especially good
cleaning material.
3. Rinse and dry glass completely before lighting a fire.
Cast Iron Door
2. Carefully remove all of the glass clips from the inside
of the door. See fig. 20a for Single Door / fig. 20b for
Double Doors.
3. Gently remove all pieces of the glass panel and gasket.
4. Remove all remaining debris from the glass area using
a wire brush.
5. Apply a small bead of gasket/stove cement and the
new gasket. Do not overlap the ends of the gasket
rope.
6. Center the new glass panel over the gasket and
reinstall the glass clips.
7. It may be necessary to retighten the glass clips after
the stove has burned and the gasket has been seated.
Door Casting
Gasket
Glass Panel
Glass Clip
Glass Clip
Glass Panel
Gasket
Figure 20a. Single Door Glass Assembly Parts.
18
M6 x 8 mm
Pan Head
Screw
Figure 20b. Double Door Glass Assembly Parts.
138344_Rev_D - C450 Kennebec 8.2.10
General Maintenance
Gaskets
• Thoroughly clean the insert. Enamel surfaces
should be cleaned with soap and water.
To check the seal of the front doors, close and latch the
doors on a dollar bill and slowly try to pull the dollar bill
free. The seal is too loose if the bill can be easily removed. Adjust the door latch and test again.
Regular maintenance will assure proper performance and prolong the life of your Jøtul C 450.
The following procedures do not take long and are
generally inexpensive. When done consistently, they
will help increase the life of your fireplace insert
and assure satisfactory performance.
• Empty firebox of all soot and ashes. Never use a
household vacuum cleaner to remove ashes. Only
a shop vac with a metal container is acceptable
and only when you are certain the ashes are cold.
Check door and glass gaskets for seal integrity.
The gaskets should be soft enough to be somewhat
resilient to the touch. Over time, gaskets will compress
and harden. Replace worn-out or hardened gaskets with
the appropriate size material available from your local
Authorized Jøtul Dealer.
• Inspect the firebox using a utility light inside and
out for cracks or leaks. Replace all cracked bricks
and repair leaks with furnace cement.
Gasket Replacement
Removing the Insert for Cleaning
1. Remove the old gasket material with a pliers and
thoroughly clean the channel with a wire brush.
U.S. Direct-connection Only:
1. Lift the Ashlip from the Ashlip Extension.
2. Remove the Ashlip Extension from the firebox by
grasping the sides and pulling it forward to disengage the three clips from their adjacent slots.
3. Remove the Surround Panel assembly by grasping the lower lip of the Breastplates and lifting it
up and off of the firebox cabinet. There are four
tabs that must be disengaged from the hangers
on either side.
4. Remove the three screws that attach the flue
connector to the flue collar, and disengage the it
from the insert.
See the Parts List on page 21 to order the correct
gasket material.
2. Lay out the new gasket around the channel to determine length. Trim the gasket to leave 1” excess.
2. Apply a small bead of furnace cement in the channel.
3. Lightly press the new gasket into the channel, being careful to avoid compressing or stretching it.
Trim the gasket further as necessary to allow the
tail end to slightly overlap the other end.
4. Wait ten minutes to allow the cement to set and
then close and latch the doors. Reopen the doors
and, using a damp cloth, wipe away any excess
cement that may be squeezed out from under the
gasket.
5. Pull the firebox and cabinet forward as a unit.
The flue connector, liner, and chimney can now
be inspected and cleaned.
6. See the Installation section of this manual for
reassembly procedures.
Canada Installations (Full Reline):
Remove the combustion baffle from the firebox by
lifting it up and tilting it back down and out. The
chimney can be swept directly into a bucket placed
under the flue outlet.
19
138344_Rev_D - C450 Kennebec 8.2.10
Jøtul C 450 Fireplace Insert
Illustrated Parts Breakdown
53
57
Tamarack Lattice Style
Surround Assembly
50
54
55
55
10
11
56
5
3
6
Kennebec Classic Style
Surround Assembly
4
32
45
40 41
35
36
31
44
34
47
48
48
43
42
9
12
33
45
14
16
18
24 25 38
19
27
46
28
29
45
7
39
45
1
49
39
61
22
15
20
62
63
64
59
20
26
8
2
15
65
38
24
17
13
58
46
60
21
23
30
52
138344_Rev_D - C450 Kennebec 8.2.10
Jøtul C 450 Parts List
No. Description
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16. 17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
Part Number
Control Door, Crosshatch Grille - Matte Black
Control Door, Crosshatch Grille - Blue Black
Control Door, Crosshatch Grille - Jøtul Iron Gray
Ashlip - Matte Black
Ashlip - Blue Black Ashlip - Jøtul Iron Gray
Kenn. Surround Leg, Left - Matte Black Kenn. Surround Leg , Left - Blue Black Kenn. Surround Leg, Left - Jøtul Iron Gray Kenn. Surround Leg, Right - Matte Black Kenn. Surround Leg, Right - Blue Black
Kenn. Surround Leg, Right - Jøtul Iron Gray Kenn. Breastplate, Left - Matte Black
Kenn. Breastplate, Left - Blue Black
Kenn. Breastplate, Left - Jøtul Iron Gray
Kenn. Breastplate, Right - Matte Black
Kenn. Breastplate, Right - Blue Black
Kenn. Breastplate, Right - Jøtul Iron Gray
Door, Left - Matte Black
Door, Left - Blue Black
Door, Left - Jøtul Iron Gray
Door, Right - Matte Black
Door, Right - Blue Black
Door, Right - Jøtul Iron Gray
Firebox
Shroud Front, Adjustable - Matte Black
Shroud Front, Adjustable - Jøtul Iron Gray
Shroud, Cabinet Sleeve
Shroud, Back Panel
Air Inlet Collar, 3” dia.
Air Channel, Back / Bottom
Shroud, Bottom
Air Channel, Front
Air Valve Handle
Front Plate
Blower Shroud (Heat Shield) Extension Shroud Retainer Clip, (3)
Ashlip Support - Right
Ashlip Support - Left
Shroud Extension, Bottom
Joint Hinge, Loose Leaf (2)
Pin Leaf, left
Pin Leaf Right
Hang Tab
Door Latch Roll Pin, 5 x 35
Door Handle (Stove Tool)
Air Manifold, Secondary
Baffle Plate
Latch, Receiver - Double Door
Air Slider
Inspection Cover
Brick Retainer
Hang Tab, Surround Panels, (4) not shown
Glass Panel, (2) - Double Door
Glass Retainer, (4)
10398092
10398027
10398085
10397992
10397927
10397985
10425992
10425927
10425985
10426092
10426027
10426085
10425792
10425727
10425785
10425892
10425827
10425885
10397492
10397427
10397485
10397592
10397527
10397585
220317
22033892
22033885
220315
220312
220502
220308
220309
220307
220318
103973
220501
222096
220385
220386
220310
220335
220334
220333
129680
220340
127064
154310
220305
103983
220349
104082
103985
103984
129680
220356
125942
40. Refractory Brick, (13)
41.
Refractory Brick, 9” x 2” (2)
42. Refractory Brick, 1 5/8” x 4 1/2” (1)
43. Refractory Brick, 9” x 3” (2)
44. Gasket, 3/8” LD Rope ( Baffle)
45. Gasket, 1/4” LD Rope / Self-adhesive (Glass)
46. Gasket, 3/8” LD Rope (Front Plate, Doors)
47. Gasket, Inspection Cover
48. Baffle Support, (2)
49. Blower 50. Convection Air Rod (Trim Rod) Matte Black
Convection Air Rod (Trim Rod) Jøtul Iron Gray
51.
Miscellaneous Hardware Bag*
52. Baffle Assembly, Complete 53. Tam. Grille Shade - Matte Black
Tam. Grille Shade - Jøtul Iron Gray
54. Tam Keystone - Matte Black
Tam Keystone - Blue Black
Tam Keystone - Jøtul Iron Gray
55. Tam. Surround Leg - Matte Black
Tam. Surround Leg - Blue Black Tam. Surround Leg - Jøtul Iron Gray
56. Tam. Breastplate, Left - Matte Black
Tam. Breastplate, Left - Blue Black
Tam. Breastplate, Left - Jøtul Iron Gray
57.
Tam. Breastplate, Right - Matte Black
Tam. Breastplate, Right - Blue Black
Tam. Breastplate, Right - Jøtul Iron Gray
129082
220390
220391
220518
100038
200024
100038
220513
220306
220522
22053192
22053185
155613
153309
22050492
22050485
10398192
10398127
10398185
10397692
10397627
10397685
10397792
10397727
10397785
10397892
10397827
10397885
58.
Front Assembly, Single Door - Matte Black
157039
59.
60.
61.
62.
63.
64.
65.
Front Assembly, Single Door - Blue Black
Front Assembly, Single Door - Jøtul Iron Gray
Replacement Single Door - Matte Black
Replacement Single Door - Blue Black
Replacement Single Door - Jøtul Iron Gray
Control Door, Vertical Grille - Matte Black
Control Door, Vertical Grille - Blue Black
Control Door, Vertical Grille - Jøtul Iron Gray
Glass Panel, Single Door
Latch Receiver, Single Door
Hinge Pin, Black (2)
Hinge Pin, Nickel (2)
M6 x 14 Button Head Cap Screw, (2)
Washers, .062 (6)
157038
157040
157036
157035
157037
157042
157041
157043
222991
225398
127075
125960
118215
117947
Jøtul C 450 Options
Mantel Heat Shield ...............................................................................155833
Kennebec Classic Surround Panel Kit, 40” x 30 1/4”
Matte Black.................................................................................... 350577
Blue Black ......................................................................................350578
Jøtul Iron . .................................................................................... 350579
Tamarack Lattice Surround Panel Kit, 40” x 30 1/4”
Matte Black.................................................................................... 350557
Blue Black ......................................................................................350558
Jøtul Iron . .................................................................................... 350559
Wide Surround Panel Kits, 47 5/8” x 34”
Matte Black . .................................................................................. 155323
Blue Black ....................................................................................155324
Jøtul Iron . ...................................................................................155354
21
138344_Rev_D - C450 Kennebec 8.2.10
Appendix A:
Alternate Floor Protection
All floor protection materials must be non-combustible i.e.. metal, brick, stone, or mineral fiberboards. No
combustible material may be used to protect the floor in
front of the fireplace insert.
Definitions:
Thermal Conductance =
C=
Btu
=
W (Hr)(ft2)(f)
(m2)(k)
R-value = Thermal Resistance
K-value = Thermal Conductivity
C-value = Thermal Conductance
Thermal Resistance =
Follow this procedure to determine if a proposed
alternate floor material meets the requirements listed in
this manual.
1. Convert the specification to R-value;
a. If R-value is given, no conversion is needed.
b. If K-value is given with a required thickness (t) in inches: R = 1/K X T.
c. If C-value is given: R = 1/C.
2. Determine the R-value of the proposed alternate floor
protector.
a. Use the formula in Step 1 to convert values not
expressed as “R ”.
b. For multiple layers, add R-values of each layer to
determine overall R-value.
3. If the overall R-value of the system is greater than the
R-value of the specified floor protector, the alternate is
acceptable.
Example:
The specified floor protector should be 3/4” thick material
with a K-factor of 0.84. The proposed alternate is 4” brick
with a C-factor of 1.25 over 1/8 inch mineral board with a
K-factor of 0.29.
Step A. Use formula above to convert specifications to R-value. R = 1/K x T = 1/.84 x .75 = .893
Step B.
Calculate r of proposed system.
4 ” brick of C - 1.25, therefore
R brick = 1/C = 1/1.25 = 0.80
1/8 ” mineral board of K = 0.29, therefore
R mineral board = 1/.29 x 0.125 = 0.431 Total R = R brick + R mineral board =
0.8 + 0.431 = 1.231
Step C. Compare proposed system R = 1.231 to specified R of 0.893. Since R is greater than required, the system is acceptable.
22
Thermal Conductivity =
K=
Btu
=
W
= (Btu)
(Hr)(ft2)(f)
(m2)(k)
(hr)(ft)(f)
R=
Btu
(Hr)(ft2)(f)
= (m2)(k)
W
= (Btu)(inch)
(hr)(ft2)(f)
The Jøtul C450 Fireplace Insert requires floor protection
having a minimum insulating R-value of 2.92.
138344_Rev_D - C450 Kennebec 8.2.10
Jøtul Wood Product Warranty
This warranty policy applies to wood-burning products identified
by Jøtul and Scan trade names, as set forth below.
A. Cast Iron, Enamel, and Steel Components:
Jøtul North America Inc. (JØTUL) warrants, to the original retail
purchaser, that those components of the Jøtul or Scan Stove
or Fireplace specified above will be free of defects in material
and workmanship for a period of five (5) years from the date of
purchase. This warranty is subject to the terms, exclusions and
limitations set forth in the following text.
B. Electrical Components (blowers, thermostatic switches):
JØTUL warrants, to the original retail purchaser, that those
components of the Jøtul or Scan Stove or Fireplace specified above
will be free of defects in material and workmanship for a period
of one (1) year from the date of purchase. This warranty is subject
to the terms, exclusions, and limitations set forth in the following
text
JØTUL will repair or replace (including parts & labor), at its
option, any of the above components determined by JØTUL to be
covered by this warranty. You must, at your own expense, arrange
to deliver or ship the component to an authorized Jøtul or Scan
dealer and arrange for pickup or delivery of the component after
repairs have been made. If, upon inspection, JØTUL determines
that the component is covered by this warranty, the repair or
replacement will be made as set forth above. This warranty is
not transferable and is extended only to, and is solely for the
benefit of, the original retail purchaser of the Jøtul or Scan Stove
or Fireplace. This paragraph sets forth the sole remedy available
under this warranty in the event of any defect in the Jøtul or Scan
Stove or Fireplace.
The warranty period for any replaced component will be the
remaining unexpired portion of the warranty period for the
original component.
Please retain your dated sales receipt in your records as proof of
purchase.
EXCLUSIONS AND LIMITATIONS
NOTICE: This warranty is void if installation or service is performed
by someone other than an authorized installer or service agency,
or if installation is not in conformance with the installation and
operating instructions contained in this owners manual or local
and/or national fire and building regulations. A listing of local
authorized installers, service agencies and gas suppliers can be
obtained from the National Fireplace Institute at http://www.
nficertified.org/.
This warranty does not cover the following:
1) Repair or replacement of parts that are subject to normal
wear and tear during the warranty period or to parts that may
require replacement in connection with normal maintenance.
These parts include paint, gaskets, burn plates, baffles, air
manifolds, firebricks, fire grates, or glass (glass is only warranted against thermal breakage).
2) Damage due to incorrect installations not in conformance
with the installation instructions contained in this owners
manual or local and/or national fire and building regulations.
3) Damage, including damage to enamel surfaces, caused by
improper operation, over-firing, and/or misuse. Improper
operation, such as burning the stove with the ash door open,
can damage the stove. Over-firing occurs when any part of the
stove glows red. Over-firing can also be identified by warped
plates, rust-colored cast iron, paint pigment that has turned
dusty white, or bubbling, cracking and discoloration of the
enamel finish. Misuse includes, without limitation, use that is
not in conformance with the operating instructions contained
in this owners manual.
4) Damage due to service performed by an installer or service
agency, unless otherwise agreed to in writing by JØTUL.
5) Damage caused by unauthorized modification, use or repair.
6) Costs incurred by travel time and/or loss of service.
7) Labor or other costs associated with the repair of components
beyond the warranty period.
8) Damage incurred while the Jøtul or Scan Stove or Fireplace is in
transit.
IN NO EVENT SHALL JØTUL, ITS PARENT COMPANY, SHAREHOLDERS,
AFFILIATES, OFFICERS, EMPLOYEES, AGENTS OR REPRESENTATIVES
BE LIABLE OR RESPONSIBLE TO YOU FOR ANY SPECIAL, INDIRECT,
INCIDENTAL, CONSEQUENTIAL, PUNITIVE OR OTHER SIMILAR
DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOST PROFITS, LOST
SALES, INJURY TO PERSON OR PROPERTY, OR DAMAGES TO A
STRUCTURE OR ITS CONTENTS, ARISING UNDER ANY THEORY OF
LAW WHATSOEVER. ALL IMPLIED WARRANTIES, INCLUDING THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, OR OTHERWISE, ARE LIMITED IN DURATION
TO THE LENGTH OF THIS WRITTEN WARRANTY. EXCEPT AS
EXPRESSLY SET FORTH HEREIN, JØTUL MAKES NO ORAL, WRITTEN
OR OTHER WARRANTY WITH RESPECT TO JØTUL OR SCAN STOVES
OR FIREPLACES.
Some states do not allow the exclusion or limitation of incidental
or consequential damages, or limitations on the length of implied
warranties. Therefore, the above exclusions or limitations may not
apply to you. This warranty gives you specific legal rights, and you
may have other rights, which vary from state to state.
JØTUL reserves the right to discontinue, modify or change the
materials used to produce the Jøtul or Scan Stove or Fireplace.
JØTUL shall have the right to replace any defective component
with substitute components determined by JØTUL to be of
substantially equal quality and price.
The dollar value of JØTULs liability for breach of this warranty
shall be limited exclusively to the cost of furnishing a replacement
component. JØTUL shall not in any event be liable for the cost
of labor expended by others in connection with any defective
component. Any costs or expenses beyond those expressly
assumed by JØTUL under the terms of this warranty shall be the
sole responsibility of the owner(s) of the Jøtul or Scan Stove or
Fireplace.
No dealer, distributor, or other person is authorized to modify,
augment, or extend this limited warranty on behalf of JØTUL.
NO MODIFICATION OR CHANGE TO THIS WARRANTY WILL
BE EFFECTIVE UNLESS IT IS MADE IN A WRITTEN DOCUMENT
MANUALLY SIGNED BY AN AUTHORIZED OFFICER OF JØTUL.
An authorized installer may have been provided with certain
information related particularly to the Jøtul or Scan Stove or
Fireplace; however, no authorized installer or other person who
may service the appliance is an agent of JØTUL. No inference
should be made that JØTUL has tested, certified, or otherwise
pronounced any person as qualified to install or service the
appliance. JØTUL shall not be liable or otherwise responsible for
any error or omission by a person installing or servicing a Jøtul or
Scan Stove or Fireplace.
If you believe your Jøtul or Scan Stove or Fireplace is defective,
you should contact your nearest authorized Jøtul or Scan dealer,
who will process a warranty claim. IN ORDER TO QUALIFY FOR
WARRANTY COVERAGE, JØTUL MUST RECEIVE NOTICE OF A
POSSIBLE DEFECT WITHIN SIXTY (60) DAYS OF THE DATE THE
DEFECT IS FIRST DISCOVERED, OR REASONABLY COULD HAVE BEEN
DISCOVERED.
This warranty is given by Jøtul North America, Inc.,
55 Hutcherson Drive, Gorham, Maine 04038 USA
23
138344_Rev_D - C450 Kennebec 8.2.10
Cat.no 138344-D August, 2010
This appliance must be installed in conformance with local and national building regulations.
It is important that the these instructions be carefully read and understood before beginning the installation. Jøtul pursues a policy of continual product development. Consequently, products may differ in
specification, color or type of accessories from those illustrated or described in various publications.
Jøtul vise sans cesse a ameliorer ses produits. C’est pourquoi, il se reserve le droit de modifier les specifications, couleurs etequipement sans avis prelable.
Jøtul North America Inc.
55 Hutcherson Dr.
Gorham, Maine 04038
USA
Jøtul ASA
P.O. Box 1411
N-1602 Fredrikstad,
Norway
24

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement