 Fully Compliant EtherNet/IP Adapter
 Fully User Configurable
Connect Modbus TCP/IP Server Devices to an
EtherNet/IP Scanner
The 460ESMC connects up to 32 Modbus TCP/IP devices to an EtherNet/IP PLC.
It’s a simple tool that allows you to use the plethora of available Modbus TCP/IP
devices in your EtherNet/IP architectures.
Modbus TCP Client
 EtherNet/IP Supports
Up To 480 Bytes of
Input Data
 EtherNet/IP Supports
Up To 480 Bytes of
Output Data
 Support for up to 32
Modbus TCP Devices
 Support Modbus Function Codes 1, 2, 3, 4, 5,
6, 15, and 16
 Effortless Browser
Based Configuration,
no programming software is required
 Simple data translation
allows you to manipulate data as it passes
between protocols
How Do I Use the 460ESMC in My Application?
For Most applications the mapping is very straight forward. Modbus Register and Coil data
is mapped to EtherNet/IP IO blocks. Up to 480 bytes of data can be moved in each
direction between EtherNet/IP and Modbus TCP/IP
It really is that simple.
Need to modify your data as it passes from one protocol to the other? No problem. Each
data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a
value, multiply by 4 and divide by 10 with ease.
Why Use Real Time Automation as a Gateway Supplier?
The 460ESMC provides an option to connect Modbus TCP/IP Server devices to an
EtherNet/IP Scanner device. While there are certainly a number of other companies
offering stand alone gateways, there is no one who provides the level of support and
service that you receive from RTA.
When you call, a live person answers the phone. When you talk with sales, you will get
honest answers and recommendations even if that means recommending someone else's
solution. When you get support, it is from an engineer who had a hand in the product’s
development, and support doesn't require a ticket or 24 hour wait. We are unashamed of
the fact that we are a smaller company because that means you mean a lot more to us.
Try the RTA difference today and give us a call at 1-800-249-1612 or check out more
information on us and our other solutions at www.rtaautomation.com.
A Word from our Founder
“It’s likely that your business isn’t industrial networking and it shouldn’t be. You make products, design systems, or manage some process. Whatever it
is that you make, monitor or install the process inevitably creates data. If you’re a control engineer and your plant has been around for a few years your
line is probably littered with devices that send out all kinds of data over many different protocols. If you’re an automation device developer you probably
have customers that need to move your data into some other network. Either way, you’ve got a device conversion problem. You have devices that generate ASCII , Modbus RTU, Modbus TCP, BACnet, Profinet, Profibus, Ethernet TCP/IP , Ethernet/IP, DeviceNet or some other completely proprietary
data and now you’re the person that has to move that data to some other network!
I feel your pain… and rather than just my sympathy, I have a solution for you. You see, while your business may not be moving data around a factory
floor mine is. In fact, it’s all that we have done for over twenty years now. Our 460 series of Device Converters is the culmination of those twenty years.
You can now move all of your data, where you want, when you want and how you want. Try us on your next project, I guarantee you wont regret it.
John Rinaldi
460ESMC
www.rtaautomation.com
ETHERNET/IP FEATURES
Operation Modes
Class 1 I/O Adapter
Message Support
Implicit Class 1 Cyclic I/O, Explicit Class 3 and UCMM Supported
Data Types
BIT8,16 & 32; INT8, 16, 32 & 64; UINT8,16, 32 & 64; Float & Double
Maximum EtherNet/IP Scanner Devices
Up to 10 can listen, only 1 can write I/O
Maximum Data Supported
Up to 480 bytes in each direction
MODBUS TCP/IP FEATURES
Modbus Operation Modes
Modbus TCP/IP Client
Function Codes Supported
1,2,3,4,5,6, 15 & 16
Swapping
Byte and Word Swapping
Maximum Modbus TCP/IP Server Devices
32
Number Read/Write Scan Lines per Server Device
200 Total - 100 reads & 100 writes
Scan Line Support
Up to 125 Registers or 512 Coils
INCLUDED WITH GATEWAY
120 volt AC wall wart power supply
Manual
6’ power cable with flying leads
5 year hardware warranty
IPSetup software — automatically locates RTA gateway on the network
Unlimited firmware feature upgrades for life
CAT5 crossover cable for direct connection to PC during programming
Complete, unlimited access to our industry leading support staff
ELECTRICAL/ENVIRONMENTAL
DC Input Voltage
8 VDC @ 230 mA to 28 VDC @ 80 mA
Maximum Baud Rate
115K baud
Operating Temperature
-40 C to 85 C
Certification
RoHS-Compliant, UL, CUL, CE Approvals, Class I Div 2
DIMENSIONS
ENCLOSURE / HARDWARE
Size
4.2” x 3.25” x 1”
Weight
5 oz.
Enclosure Type
Anodized aluminum
Mounting
Din rail or panel mount
LEDs
Ethernet link/data LED, Ethernet speed LED, power LED, &
2 general purpose LEDS on side
GATWAY FEATURES & FUNCTIONS
Gateway Security
You can configure up to 9 different users access to
diagnostic and configuration screens.
Alarming
Set <, <=, >=, >, ==, !=, and change-of-state rules on
any data moving through the gateway. If alarm rule is
triggered an email notification can be sent.
Translation Table
Allows for data manipulation during protocol translation. Scaling and other data format changes can occur
in the gateway.
Status and
Counters
Protocol specific status, counters and error messages
are accessible within the gateways diagnostics page.
They can also be delivered to a connected device.
Diagnostic Logging
Page
Allows users to see and log start up sequences, protocol specific messages & error messages.
NOT EXACTLY WHAT YOU WERE LOOKING FOR?
Real Time Automation offers a full line of gateway products. If this isn’t the one
you were looking for chances are we still have right solution for you. Give us a
call at 1-800-249-1612 or check out a listing at www.rtaautomation.com/products.
We also offer custom gateways to help customers dealing with unique needs or
proprietary protocols.
CATALOG #
DESCRIPTION
460ESMC
EtherNet/IP Scanners to Modbus TCP/IP Server Gateway
For More Information:
1-800-249-1612
[email protected]
.
www.rtaautomation.com
2014 Copyright Real Time Automation. All rights reserved. The Real Time Automation logo is a registered trademark of Real Time Automation Inc.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement