AD-1687 Setting Tool Instruction Manual
==================================================================
By using the ”AD-1687 Setting Tool” for the AD-1687,
1: Internal settings can be changed on your computer screen.
2: Internal settings can be reset to factory settings.
3: A function where upper and lower limits can be set and HI LO is displayable can
be used.
==================================================================
1.Terms of Use
==================================================================
• Copying “AD-1687 Setting Tool” without A&D’s permission is prohibited.
• Specifications for “AD-1687 Setting Tool” may change without notice.
• All rights to “AD-1687 Setting Tool” belong to A&D.
• A&D bears no liability for direct, indirect, special, incidental, or consequential
damages resulting from any defect in the AD-1687 Setting Tool program or the
AD-1687 Setting Tool Instruction Manual, even when advised of the possibility of such
damage. A&D is not responsible for any assertions of rights by third parties. A&D is
not responsible or liable for the loss of any programs and/or data stored in the
computer on which WinCT-AD1687 is installed, including the costs of recovering said
lost programs or data.
==================================================================
2. System Requirements
==================================================================
OS
Windows XP
SP3 or later
Display
XGA(1024 x 768) or higher
==================================================================
3. Before Installing
==================================================================
Before using “AD-1687 Setting Tool”, please be sure to back up any important data on
your computer.
==================================================================
4. Installing the "AD-1687 Setting Tool"
==================================================================
Unzip the AD-1687 Setting Tool.zip file in an appropriate folder.
==================================================================
5. Uninstalling "AD-1687 Setting Tool"
==================================================================
Delete the folder where AD-1687 Setting Tool.exe is installed.
==================================================================
6. Starting and Using the Program
==================================================================
1: Connect the AD-1687 to your PC using a USB cable
2: Select “CSV FILE” on the AD-1687 and hit the <ENTER> key.
USB
>
CSV FILE
EXT. POWER
REAL TIME
3: Double click “AD-1687 Setting Tool.exe” in the unzipped folder.
4: Select the drive which the AD-1687 is connected to and hit OK
At this point, the internal settings saved in the AD-1687 will be read and
displayed on-screen.
Select the connected
hard drive
Note: Do not select a drive besides the one the AD-1687 is connected to.
5: Functions of the various areas
> INTERVAL TIME
1min
PRIMARY DATA
T1 / %RH
TEMP. UNIT
°C
RECORDING TYPE
ONE-TIME
BUZZER
ON
DECIMAL POINT
DOT[ . ]
BAUD RATE
2400bps
BITS PARITY
7bits/EVEN
TERMINATOR
<CR><LF>
POWER SAVE
1min
DATE FORMAT
yyyy/mm/dd
DATE SETTING
2012/03/19
TIME SETTING
15: 05: 31
ID NUMBER
00000000
CONTRAST
40
AD-1687 Internal Settings Screen
For more info on the limit function,
Return all settings to factory defaults
Refer to 7. Limit Function
Setting Item
Values and functionality
INTERVAL TIME
Recording intervals for the AD-1687
1, 2, 5, 10, 15, 20, 30 seconds
1*, 2, 5, 10, 15, 20, 30, 60 minutes
• Which items are displayed in the AD-1687 option
screen?
• Items using the limit function
Temp 1*, Humidity, Barometric pressure, Temp 2 (only
when connected), Vibration, Balance
• Which items are displayed in the AD1687 option screen?
• Items using the limit function
Temp. 1, Humidity*, Barometric Pressure, Temp. 2 (only
when connected), Vibration, Balance
PRIMARY DATA 1
PRIMARY DATA 2
RECORDING TYPE
BUZZER
DECIMAL POINT
TERMINATOR
BITS PARITY
When data is full, does the device overwrite and save?
One-time*••• Does not overwrite when memory is full
Endless ••• Does overwrite when memory is full
Does the buzzer sound during weighing data input/ usage
of the limit function
Sound*
No sound
Decimals displayed and saved to the AD1687
Dot ( . )*
Comma ( , )
Settings for connection to the balance
<CR><LF>*
<CR>
Settings for connection to the balance
7bits/EVEN*, 7bits/ODD, 8bits/NONE
BAUD RATE
Settings for connection to the balance
600, 1200, 2400*, 4800, 9600, 19200bps
POWER SAVE
Time elapsing without input before turning
power/display
No power-save, 30 seconds, 1*, 2, 5, 10 minutes
DATE FORMAT
Order of year, month, and day
Year/month/day*, month/day/year, day/month/year
DATE/TIME SETTING
Time setting
Auto••• Records the time set on the PC
Manual••• Choose your own setting
ID number settings
8-digit value. Example: AND-1687
ID NUMBER
CONTRAST
Screen contrast
25 to 40* to 50
LIMIT UPPER/LOWER
Limit function settings
* Refer to “7. Limit function”
off
*: Factory settings
6: When returning settings to factory defaults
Press the Factory Default Settings button. All settings will be returned to factory
defaults. When this happens, settings are not saved on the AD-1687 yet.
7: Confirm settings
After changing the necessary settings, press the Set button.
8: To make the changes take effect, you must turn off the power for the AD-1687
and restart it.
1: Left-click “Safely remove hardware” on the taskbar and sever the connection.
2: If you see the “Hardware removed” message, pull the USB cable from the
AD-1687.
3: Press and hold the AD-1687’s [ON/OFF] key, and turn it off.
9: Quit the Setting Tool
Pressing the quit button in the upper right will close the program.
==================================================================
7. About the Limit Function
==================================================================
• There is a “limit function” that will display HI, LO on the AD-1687 and sound a
buzzer when environmental values pass set limits
• It’s possible to quickly be informed of irregularities through a buzzer and/or
display when certain limits are exceeded, such as in climate controlled room.
1: Please go to Step 5: "Functions of the various areas" of “6. Starting and Using
the Program”
2: Select the item that will use the limit function.
Limits will be applied to the settings in “Primary data 1, 2”.
Note: The limit function cannot be used on “vibrations” or “balance”.
When using the limit function, please do not select these.
3: Select whether to enable the limit function
To use the limit function on the settings displayed in “Primary data 1, 2”,
click ON
4: Set the upper and lower limits for the limit function
Input the upper and lower limits.
5: After changing settings for the limit function
Refer to the steps following “7. Confirm settings” from “6. Starting and Using
the Program” and enable the setting changes made to the limit function.
6: The AD-1687’s display
When the upper/lower limit values set using the Setting Tool are passed,
HI/LO will be displayed, or the unit area will reverse from black to white and
a buzzer will be sounded.
T1
HI
25.8 °C
RH
LO
36.8 %
BAR
VIB
995.3 hPa
2 mG
T1
HI
25.8
RH
°C
LO
36.8
%
7: Stopping the limit function
To stop the limit function, use the Setting Tool again, and click OFF
Refer to the steps following “7. Confirm settings” from “6. Starting and Using
the Program” and enable the setting changes made to the limit function.
==================================================================
8. Usage Example for the Limit Function
==================================================================
An actual example showing how to use the limit function is below.
Conditions
Temp Upper limit: 25.0°C
Lower limit: 23.0°C
Humidity Upper limit: 50.0%
Lower limit: 40.0%
1: Follow the steps all the way up to “5. Functions of the various areas” from
“6. Starting and Using the Program”
2: In Primary Data 1 set “Temperature 1”, and in Primary Data 2 set “Humidity”
3: To enable the limit function, click “ON”
4: Input upper/lower limits
Temp Upper limit: 25.0°C
Lower limit: 23.0°C
Humidity Upper limit: 50.0%
Lower limit: 40.0%
5: Click the Set button
6: Apply the setting changes
Refer to the steps following “7: Confirm settings” from “6. Starting and Using the
Program” and enable the limit function changes to the AD-1687.
7: Confirm the AD-1687 display.
Temp Upper limit: 25.0°C
Lower limit: 23.0°C
Humidity Upper limit: 50.0%
Lower limit: 40.0%
When the set limits are exceeded, HI, LO will be displayed, and the buzzer will
go off.
T1
HI
25.8 °C
RH
LO
36.8 %
BAR
VIB
995.3 hPa
2 mG
8: To stop the limit function, click OFF
T1
HI
25.8
RH
°C
LO
36.9
%
Was this manual useful for you? yes no