N1000R-66_2006

N1000R-66_2006
COOLING PUMPS FOR
HELIARC WELDING
PUMP MAINTENANCE AND REPAIR
Oberdorfer gear pumps are essentially maintenance-free. If
the pump is to be shut down for an extended period of time, it
should be flushed thoroughly and filled with lubricating oil.
As a general rule, it is seldom economical to repair a worn
out gear pump. However, if the gear chamber inside the pump
body is still in good condition, the replacement of all interior parts
by use of a repair kit may restore up to 80% of the original pump
performance. Repair kit numbers and parts contained in each kit
are listed on the parts lists on the reverse side.
N1000R-66*
N95060GEC03
N95060GFC01
N95060GE IS
NOT PICTURED
Pum p #
RPM
PERFORMANCE
PSI
0
20
40
60
80
100
1725
GPM
1.5
1.4
1.3
1.2
1.1
1
1725
GPM
2.1
1.9
1.8
1.7
1.6
1.5
N1000R39
N95060GEC03
N95060GFC01
N1000R-66*
N1000R39
GENERAL INFORMATION
TYPICAL PUMP INSTALLATION
Oberdorfer has a long history of supplying pumps to the
welding machine industry. Ever since the Heliarc welding technology was developed, Oberdorfer pumps were used to circulate cooling liquid to the welder’s torch.
Pump and electric motor are usually mounted on top or
on the side of the coolant tank. A pressure relief valve built into
the pump returns excess liquid directly to the tank rather than to
the suction side of the pump, thus avoiding heat build-up in the
pump.
Pump models N1000R39 and N1000R-66* are coupled
to the electric motor with a flexible coupling. The N95060GEC03
and N95060GFC01 models are close-coupled to a carbonator
motor by a circular clamp arrangement, offering a space-saving,
compact design alternative. Pump model N95060GE is a retrofit for Miller Electric Mfg. Co.
The reasons for the wide acceptance of Oberdorfer
pumps in the welding machine industry are reliability, long service life, and ease of maintenance. The pumps depicted on this
page are being produced in quantities for several welding
machine manufacturers in the U.S.A.
*Replaces the 1000R-53
www.oberdorfer-pumps.com
PHONE (800) 448-1668; (315) 437-0361
FAX (315) 463-9561
COOLING PUMPS FOR
HELIARC WELDING
EXPLODED VIEW
AND PARTS LIST
Pump
Item
1
2
3
4
5
6
7
8
9
10
#
Name
Screw
Body
Dowel
O-Ring
Bearing
Idle
Drive
Bearing
Cover
Snap
Gear
Gear
Req.
6
1
2
1
2
1
1
2
1
1
5013
9301NB5N
8885
9797-033
8990
32629
32884
5024
9305NN4R
5373
Pin
N95060GEC03
Ring
N5060GFC01
5013
9301NB5N
8885
9797-033
8990
32629
32884
5024
9305NN4R
5373
N95060GE
5013
9301NB5N
8885
9797-033
8990
32629
32884
8990
9305NNZR
5373
11
12
13
14
15
16
17
18
19
20
Seal
Snap
Coupler
Clamp
Poppet
Spring
Adj.
Washer
Lock
Valve
Repair
Assy.
Ring
Nut
Nut
Kit*
1
1
1
1
1
1
1
2
1
1
32584
7639
9175
8840
7640
5806
5766
6966
5774
5767
32584
7639
9175
8840
7640
9718
----
----
----
----
11936
32584
7639
----
----
7640
5806
5766
6966
5774
5767
11937
Screw
11936
* Repair Kit contains items 4,5,6,7, 8, 10, 11, 12
Pump
Item
1
2
3
4
6
8
9
10
#
Name
Body
Cover
Carbon
Dowel
O-Ring
Screw
Drive
Idle
Bearing
Pin
Gear
Gear
4
2
1
6
1
1
1
8885
9797-033
5385
32133
32118
8885
9797-033
5385
32687
32584
Req.
1
1
9313NB2N 9314NN5L
5024
N1000R39
5024
N1000R-66* 9311NB4N 9314NN5L
* Repair Kit contains items 3, 6, 9 10 & Seal.
5/06
www.oberdorfer-pumps.com
11
13
14
15
16
17
Adj
Lock
Valve
Fiber
Seal,
Seal,
Repair
Screw
Nut
Nut
Washer
Lip
Mech.
Kit*
1
1
1
1
3
1
1
7640
5806
5766
5774
5767
6966
5007
----
11187
7640
5806
5766
5774
5767
6966
----
32584
11925
Poppet Spring
19,20 21,22,23
Specifications are subject to change without notification.
PHONE (800) 448-1668; (315) 437-0361
FAX (315) 463-9561