Please read this document carefully before using this product. The guarantee will be invalidated if the device is damaged by not following instructions detailed in the manual. The company shall not be responsible for any damage or losses however caused, which may be experienced as a result of the installation or use of this product.
ENDA ETC1311 DIGITAL THERMOSTAT
Thank you for choosing ENDA ETC1311 temperature controller.
* 35 x 77mm sized.
* On-Off control.
* J, K, Pt100 or Pt1000 input.
* Temperature compensation.
* In the case of probe failure, heating can be
selected on, off or periodical running.
* Upper and lower limits of the setpoint can be
adjusted.
* Set value can be adjusted by using single key.
* CE marked according to European Norms.
OUT
Order Code : ETC1311- - -
1 2 3
1 - Input
FE.....Fe-Const (J)
RT.....Pt100
PT.....Pt1000
K.......NiCr-Ni (K)
2 - Supply Voltage
230VAC...230V AC
24VAC.....24V AC
12VAC.....12V AC
SM...........9-30V DC / 7-24V AC
ENDA
3 - Output
P......... Relay-16A
None...Relay-8A
SSR....Logic output
°C
ETC1311
Connection Diagram
ENDA ETC1311 is intended for installation in control panels. Make sure that the device is used only for intended purpose. The electrical connections must be carried out by a qualified staff and must be according to the relevant locally applicable regulations. During an installation, all of the cables that are connected to the device must be free of electrical power. The device must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. The cables should not be close to the power cables or components.
ENDA
INDUSTRIAL ELECTRONICS
ETC1311-K-230VAC
DIGITAL THERMOSTAT
SN: XXXXXXXXX
K (NiCr-Ni)
+
1 2 3 4 5 6 7 8 9 10 11 12
ENDA
INDUSTRIAL ELECTRONICS
ETC1311-FE-SM-P
DIGITAL THERMOSTAT
SN: XXXXXXXXX
J (Fe-CuNi)
1 2 3
+
4 5 6 7 8 9 10 11 12
ENDA
INDUSTRIAL ELECTRONICS
ETC1311-RT-12VAC
DIGITAL THERMOSTAT
SN: XXXXXXXXX
Pt100
1 2 3 4 5 6 7 8 9 10 11 12
Equipment is protected throughout by DOUBLE INSULATION.
NOTE:
SUPPLY:
184-253V AC
50/60Hz 4VA
4
5
Holding screw 0.4-0.5Nm
Line
Neutral
Fuse
F 100 mA
250V AC
Switch
230V AC
Supply
Fuse should be connected
Cable size: 1,5mm²
Note:
1) Mains supply cords shall meet the requirements of
IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power
supply switch shall bring the identification of the
relevant instrument and it should be easily
accessible by the operator.
1/2
Technical Specifications
ENVIRONMENTAL CONDITIONS
Ambient/storage temperature 0 ... +50°C/-25 ... 70°C (with no icing)
Max. relative humidity
Rated pollution degree
Height
80 , up to 31°C decreasing linearly 50% at 40 °C
According to EN 60529 Front panel : IP65
Rear panel : IP20
Max. 2000m
Do not use the device in locations subject to corrosive and flammable gasses.
ELECTRICAL CHARACTERISTICS
Supply voltage
Power consumption
Wiring
Scale
Accuracy
Indicator
EMC
Safety requirements
Max. 4VA
2.5mm² screw-terminal connections.
0 .... +600°C for Fe-Const (J) and NiCr-Ni (K). -100 .... +600°C for Pt100 and Pt1000
± 0.5% (of full scale) ±1 digit
3 digits, 14.2mm, 7 segment red LED
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.
The device is designed to operate in controlled electromagnetic environment)
EN 61010-1: 2001 (Pollution degree 2, overvoltage category II)
OUTPUT
HEAT OUT
Life expectancy for relay
For ETC1311-XX-XX ; Relay: 250VAC, 8A( for resistive load ), NO+NC,
For ETC1311-XX-XX-P ; Relay: 240VAC, 16A(for resistive load), NO or 12VDC 20mA logic out.
For ETC1311-XX-XX ; Mechanical 30.000.000; Electrical 100.000 operation.
For ETC1311-XX-XX-P ; Mechanical 30.000.000; Electrical 30.000 operation.
CONTROL
Control type
Control algorithm
Hysteresis
Single-setpoint control
On-Off control
Adjustable between 1 ... 20°C.
HOUSING
Housing type
Dimensions
Weight
Enclosure material
Suitable for flush-panel mounting.
W77xH35xD71mm
Approx. 198g (A fter packing )
Self extinguishing plastics
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
Dimensions
OUT
77mm
°C
For removing mounting clamps:
Push the flush-mounting clamp in direction 1 as shown in the figure below. Then, pull out the clamp in direction 2.
Depth
71mm 5mm
ENDA ETC1311
+
12
-
11 10 9 8 7 6 5 4 3 2 1
S NIC RO CT LE L E
T TA
RIA
C
ST
VA
OS
DU
30
RM HE
XX XX
1-K
AL
31
DA
XX XX
C1
DIG
SN
ET
EN
Flush mounting clamp
Panel cut-out
71mm
Flush mounting clamp
1
2
Panel
Rubber packing
should be maximum
7 mm.
2) If there is no 60mm
free space at the back
side of the device, it
would be difficult to
remove it from the
Panel.
SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ.
Yukarý Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL/TÜRKÝYE
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01 url : www.enda.com.tr
ETC1311-E-10-R
HEATING OUT
LED
OUT
ENDA
°C
ETC1311
Displayed process value in the run mode, parameter name or value in programming mode.
Used for selecting menu and increasing setpoint value of the parameters in the programming mode and for increasing the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates.
Used for selecting parameters and decreasing the setpoint value in the programming mode and for decreasing the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates.
Used for adjusting the value of the setpoint in the run mode and for adjusting the selected parameter in the programming mode.
PRG
While holding key, setpoint value of the selected parameter appears and by using and keys the value can be adjusted.
Run mode
Process
Value
200 199 200
If no key is pressed
for 3 seconds
When pressed or key, temperature set value flashes and by using and keys the value can be adjusted.
If no key is pressed for 3 seconds run mode is returned.
PRG
If key is pressed and held for 3 seconds,
programming mode is entered.
Con
Hys
Switch hysteresis for the setpoint.
Upl
The upper limit of the setpoint.
Lol
The lower limit of the setpoint.
Programming Mode
SeC
Cod
Access code for menu of security.
Enter 311 then press key.
Aco
Security parameter for menu of configuration.
Non
Pye
= Menu is invisible.
= Parameters of menu are changeable.
Pno
= Parameters of menu are only visible.
Ase
Security parameter for temperature set value.
Pye
= Set value is changeable.
Pno
= Set value is only visible.
PRG
If key is pressed,
run mode is entered.
PARAMETER TABLE
Menu of Configuration parameters Con
Hys
Upl
LoL
Eon
Ect
E oFs
SEC
Aco
ASE
MIN MAX UNIT DEF.SET falls to SET-HYS, output relay becomes active.)
The upper limit of the setpoint.
The lower limit of the setpoint.
Pt100
LoL
600 °C 600
UPL
°C 0
-99
UPL
°C -99
0 100 % Ect 0
10 250 sec 30
-99 99 °C 0
In the case of error, period of the relay output.
Offset value.
Menu of Parameter security
Security parameter for menu of configuration.
Non
= Menu is invisible.
Pye
= Parameters of menu are changeable.
Pno
= Parameters of menu are only visible.
Security parameter for temperature set value.
Pye
= Set value is changeable.
Pno
= Set value is only visible.
Eon
In the case of error, on time rate of the relay output.
Ect
In the case of error, period of the relay output.
Offset value
Means, temperature value is higher than the scale.
___
Pfa
Means, temperature value is lower than the scale.
Means, temperature sensor is broken or over temperature.
ETC1311-E-10-R
2/2