Bellfires Horizon Bell Small Tunnel 3 Installation Manual


Add to my manuals
96 Pages

advertisement

Bellfires Horizon Bell Small Tunnel 3 Installation Manual | Manualzz
INSTALLATION INSTRUCTIONS &
MANUAL FOR MAINTENANCE
HORIZON BELL
SMALL TUNNEL 3
CF/LF
Gas fires with closed combustion system
Bellfires wishes you many cosy evenings with your new Bellfires gas fire
This document is an essential part of your gas fire.
Read it carefully before installation and maintenance of the
gas fire and keep it in a safe place!
Serial number:
Production date:
Bellfires
English
BELLFIRES GAS FIRE WITH CLOSED COMBUSTION SYSTEM:
Horizon Bell Small Tunnel 3 CF (Centre Fire)
(HBST3 CF)
Horizon Bell Small Tunnel 3 LF (Line Fire)
(HBST3 LF)
Installation instructions
3
Bellfires
4
English
Installation instructions
Bellfires
English
CONTENTS
Page
1. INSTALLATION INSTRUCTIONS ..............................................................
7
2. MAINTENANCE .........................................................................................
67
3. FAULTS ......................................................................................................
68
4. DISMANTLING / ASSEMBLING OF THE GLASS .....................................
69
5. DIAGRAM ELECTRICITY AND GAS .........................................................
75
6. DIMENSIONS .............................................................................................
76
7. TECHNICAL DETAILS/REGULATIONS .....................................................
86
8. REPLACEMENT PARTS LIST ...................................................................
90
9. DISPOSAL OF PACKAGING AND APPLIANCE ........................................
93
IMPORTANT
The installation must only be carried out by a
“Gas Safe Register” registered installation engineer.
Installation instructions
5
Bellfires
6
English
Installation instructions
Bellfires
1
English
INSTALLATION INSTRUCTIONS
1.1 GENERAL
The gas fire must be positioned and connected as a “room sealed system” (balance
flue) appliance by a “Gas Safe Register” registered gas installation engineer in
accordance with the following installation instructions, nationally and locally applicable
regulations (see “Technical Details/ Regulations” at the rear of this manual). If you have
any queries regarding the installation, please consult your local gas company.
Important:
Before beginning the installation, check that the details on the
rating plate correspond to the gas type and pressure to which
the appliance will be connected.
The appliance is supplied with a “Centre Fire” or “Line Fire” double burner, as ordered.
These burners each have their own specific flame image which is defined by the
perforation pattern in the burner cover. See Chapter 5 and the Instructions for use.
The appliance is factory set to the correct nominal heat input. The pilot light is set to the
correct level of consumption.
Depending on the requested version, the appliance will be delivered from the factory
with a Ø100 mm - Ø150 mm or Ø130 mm - Ø200 mm concentric connection for
extracting the flue gases and supply of combustion air.
It is possible to install the gas fire with either a wall or roof outlet.
The roof connection must be carried out using the concentric flue system Ø100 mm Ø150 mm. The fumes are exhausted naturally to the outside environment through the
inner Ø100 mm pipe whereas the combustion air supply passes between the Ø100 mm
and Ø150 mm pipes.
The wall connection must be carried out using the concentric flue system Ø130 mm Ø200 mm. The flue gases are evacuated outside by means of natural draft through the
internal pipe of Ø130 mm, whereas the combustion air is supplied between the pipes of
Ø130 mm and Ø200 mm. The wall outlet itself is, depending on the concentric flue gas
system configuration, Ø100 mm - Ø150 mm or Ø130 mm - Ø200 mm. (In some cases,
with a wall connection, a complete concentric flue system Ø100 mm - Ø150 mm is also
possible (see Chapter 1.6.1).)
The gas fire can be installed in a completely sealed or mechanically ventilated house
without extra ventilation and/or fume extraction.
The gas fire is installed as a built-in appliance in a fireplace.
In order to prevent the fireplace heating up excessively, it must be properly
ventilated by installing vents at the top and bottom of the fireplace.
Installation instructions
7
Bellfires
English
The appliance can be fitted with a convection package as an optional extra. This is a
convection top plate for on top of the appliance, two flexible aluminium pipes and two
built-in convection vents. This enables hot air to be circulated into the room.
If required, two additional convector grills can be fitted (= 1x extra convection set).
If an existing chimney is to be used, please consult your installer first. If the chimney
was previously used for a wood or coal fire, then it should be cleaned by an expert.
1.2 CONCENTRIC FLUE SYSTEMS Ø100 MM - Ø150 MM AND
Ø130 MM - Ø200 MM : • Bellfires (Muelink & Grol system)
• Poujoulat (PGI system)
• Ontop
(Metaloterm US system)
The gas fire, in combination with the concentric flue system [Ø100 mm - Ø150 mm] and/
or [Ø130 mm - Ø200 mm] (rigid and/or flexible) for the brands Bellfires (Muelink & Grol
system), Poujoulat (PGI system) or Ontop (Metaloterm US system), has been approved
in accordance with the European CE-norm for gas appliances and may therefore be
used only with these systems. The permitted components for these systems are listed
in Chapter 1.6.2. The guarantee on the appliance lapses if it is installed, fully or partially,
with other components or a different flue system.
The concentric flue [Ø100 mm - Ø150 mm] and [Ø130 mm - Ø200 mm] systems can be
used with either a newly-built or existing chimney.
1.3 INCLUDED
Set documentation
- Instructions for use
- Installation instructions
Attributes
- Ceramic log set, or
marble pebbles white or marble pebbles grey
- Hook (for opening the frame and the glass)
N.B. If any part is missing, please contact your dealer.
8
Installation instructions
Bellfires
1.4
English
OPTIONS AND ACCESSORIES
The following options and accessories can be supplied by your dealer:
Part no
Option
Convection package Horizon Bell Small Tunnel 3
332133
312829
• 1x Top plate Convection
• 1x Convection set General
330361
Set of high adjustable feet (4 pieces)
311967
Mantle iron L = 1250 mm
Part no
Accessorie
312829
Convection set General: (for convection air extraction)
302188
310178
309872
309730
304040
•
•
•
•
•
1x Flexible aluminium pipe Ø125 mm, L= 3 m (max.)
2x Fitting box 135 x 135 mm
2x Convection exit grid, white, 145 x 145 mm
2x Collar adaptor Ø125 mm
4x Hose clamp Ø125 mm
329874
Set carrying brackets (2 pieces)
3........
Bellfires (M&G) concentric flue system
See component summary
3........
Poujoulat (PGI) concentric flue system
See component summary
3........
Ontop (Metaloterm US) concentric flue system
See component summary
Installation instructions
9
Bellfires
1.5
English
PREPARATION FOR INSTALLATION
The following preparation must be carried out before the gas fire can be installed.
1.5.1
Instructions for positioning the outlet
1.5.1.1 Positioning the outlet for correct operation:
Roof-mounted outlet:
>0.5 m
Figure 1: Roof-mounted outlet
This must be positioned at least 0.5 m from the roof edge;
the apex of the roof can be disregarded.
Wall-mounted outlet:
>0.5 m
Figure 2: Wall-mounted outlet
This must be positioned at least 0.5 m from:
• the corner of the building.
• the roof overhang, the rain gutter.
• balconies etc., unless the exhaust construction
extends to at least the face of the protruding section.
10
Installation instructions
Bellfires
English
1.5.1.2. Positioning the outlet to avoid affecting the surrounding area
All listed “distances” in this section are no more than
guidelines.
For the exact minimum “distances”, please consult your
national and local directives.
“Distance” = minimum distance required for positioning of the outlet to avoid
adverse effects with respect to:
A. A ventilation opening serving an occupied room, a toilet or a bathroom.
B. A heating air supply, when the supply flows through an occupied room.
C. A window that can be opened and that is near an occupied room, a toilet
or a bathroom.
Roof-mounted outlet:
To avoid adverse effects
(*)
Distance: outlet - A, B or C
At the same roof level.
>3 m (*)
At a different roof level.
>1 m (*)
At a lower positioned wall.
>1 m
At a higher sloping surface.
>3 m (**)
If the required distance cannot be achieved, the outlet position rules take
precedence.
(**) If the required distance cannot be achieved, the position of the outlet must
be at least 1 m above the highest facade/roof.
Installation instructions
11
Bellfires
English
Wall-mounted outlet:
To avoid adverse effects
Distance: outlet - A, B or C
At walls in buildings with staggered
heights.
Not permitted if A, B, or C are located
above the outlet.
On a wall - general. (*)
Above the outlet:
Below the outlet:
Left and right of the outlet:
At <1 m from the roof overhang.
>2 m
Beneath balconies, walkways etc.
>2 m from the underside of the
protruding balcony or walkway.
Beneath balconies, walkways
etc. where the outlet extends to
the front.
>2 m
To the garden or on the terrace.
>2 m to the outside space. (**)
With respect to a facing wall.
>2 m (if the distance from the facing
wall is less, the criteria detailed for
“On a wall - general” apply).
>2 m
>0.75 m
>0.75 m
Enquire at your local gas company for the regulations relating to outlets
positioned opposite each other and outlet(s) in facade(s) that form an angle.
(*)
These minimum distances do not apply if there is an obstruction
between the outlet and A, B and C that protrudes at least 0.5 m from
the wall and has a length exceeding the distance.
(**)
This distance is not required if the outlet is situated at least 1 m
higher than the intended area of the outside space.
If the outlet has a clearance of less than 0.5 m from the hard surface of a public area at
a height of less than 2 m, it must be fitted with an effective protector. The mesh size of
the guard must not affect the correct operation of the appliance.
12
Installation instructions
Bellfires
1.6
English
GENERAL SERVICES
1.6.1 The Fume Channel/Combustion Air Intake
The combined fume channel and combustion air intake requires one of the following
concentric flue system configurations.
Important:
Due to the high temperature of the outer walls
(approx. 150°C), no flammable materials may be located
or used in the vicinity of the flue system.
The complete flue system, must therefore be sleeved
with a heat resistant material after assembly.
Ventilate the covered concentric flue by fitting a
grid near the floor and ceiling (on each floor).
Do not insulate the concentric flue.
Use the universal wall/floor support Ø150 mm
to attach the covering of the concentric flue system
[Ø100 mm - Ø150 mm], see 1.6.2, drawing number 36.
36
36
Use as a wall support
Use as a floor support
Figure 3: Application universal wall/floor support Ø150 mm
Installation instructions
13
Bellfires
English
RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION
POSSIBILITIES
Appliance: Concentric flue connection Ø100-Ø150 mm or Ø130-Ø200 mm
16
17
16
Y
18
24
23
28
10, 11, 12, 13
24
(100)
4
23
1
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance:
Distance Y
(min.-max.)
Concentric
connection
on appliance is
Ø100-Ø150 mm
Concentric
connection
on appliance is
Ø130-Ø200 mm
2.0 - 4.0 m
Width:
B = 30 mm
Width:
B = 65 mm
4.0 - 12.0 m
Width:
B = 40 mm
Width:
B = 80 mm
Horizon Bell Small Tunnel 3
Figure 4: Vertical roof-mounted outlet without bend
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
14
Installation instructions
Bellfires
English
16
17
Y2
24
23
X
14, 15
23
Y1
10, 11, 12, 13
23
28
(100)
4
1
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance:
Horizon Bell
Small Tunnel 3
Distance Y1 (*)
(min.-max.)
1.0 - 11.0 m
Distance X (*) Distance Y1 + Y2 (*)
(min.-max.)
(min.-max.)
0 - 3.0 m
1.0 - 11.0 m
Concentric
connection
on appliance is
Ø100-Ø150 mm
-
Concentric
connection
on appliance is
Ø130-Ø200 mm
Width:
B = 40 mm
(*) : (Y1 + Y2) : X > 2 : 1
(Vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
Figure 5: Vertical roof-mounted outlet with bend
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Installation instructions
15
Bellfires
English
FLEXIBLE CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION
POSSIBILITIES
Appliance: Concentric flue connection Ø100-Ø150 mm or Ø130-Ø200 mm
32
18
30
29
5
Y
7
29
26
25
10, 11, 12, 13
23
28
4
(100)
1
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance:
Distance Y
(min.-max.)
Concentric
connection
on appliance is
Ø100-Ø150 mm
Concentric
connection
on appliance is
Ø130-Ø200 mm
2.0 - 4.0 m
Width:
B = 30 mm
Width:
B = 65 mm
4.0 - 12.0 m
Width:
B = 40 mm
Width:
B = 80 mm
Horizon Bell Small Tunnel 3
Figure 6:
Vertical chimney outlet using an existing lined chimney
(Flexible Ø100 mm and/or rigid Ø100 mm / Ø150 mm)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
16
Installation instructions
Bellfires
English
32
18
30
29
Y3
Y2
> 45°
5
X
7
29
26
25
Y1
10, 11, 12, 13
23
28
(100)
4
1
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance:
Distance Y1 (*) Distance X (*) Distance Y1 + Y2 + Y3 (*)
(min.-max.)
(min.-max.)
(min.-max.)
Horizon Bell
Small Tunnel 3
1.0 - 11.0 m
0 - 3.0 m
1.0 - 11.0 m
Concentric
connection
on appliance is
Ø100-Ø150 mm
-
Concentric
connection
on appliance is
Ø130-Ø200 mm
Width:
B = 40 mm
(*) : (Y1 + Y2+ Y3) : X > 2 : 1
(Vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
Figure 7:
Vertical chimney outlet using a lined chimney with a bend > 45°
(Flexible Ø100 mm and/or rigid Ø100 mm / Ø150 mm)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Installation instructions
17
Bellfires
English
32
18
31
30
29
29
6
Y
8
7
27
28
29
26
29
(100)
4
1
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance:
Distance Y
(min.-max.)
Concentric
connection
on appliance is
Ø100-Ø150 mm
Concentric
connection
on appliance is
Ø130-Ø200 mm
2.0 - 4.0 m
Width:
B = 30 mm
Width:
B = 65 mm
4.0 - 12.0 m
Width:
B = 40 mm
Width:
B = 80 mm
Horizon Bell Small Tunnel 3
Figure 8:
Vertical chimney outlet using an existing unsound lined
chimney or when no chimney liners are present
(Flexible Ø100 mm / Ø150 mm)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
18
Installation instructions
Bellfires
English
32
18
31
29
Y3
30
29
Y2
6
> 45°
8
X
7
Y1
27
28
29
26
29
(100)
4
1
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance:
Horizon Bell
Small Tunnel 3
Distance Y1 (*) Distance X (*) Distance Y1 + Y2 + Y3 (*)
(min.-max.)
(min.-max.)
(min.-max.)
1.0 - 11.0 m
0 - 3.0 m
1.0 - 11.0 m
Concentric
connection
on appliance is
Ø100-Ø150 mm
Concentric
connection
on appliance is
Ø130-Ø200 mm
-
Width:
B = 40 mm
(*) : (Y1 + Y2+ Y3) : X > 2 : 1
(Vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
Figure 9:
Vertical chimney outlet using an existing unsound lined
chimney or when the chimney is unlined; with a bend >45o
(Flexible Ø100 mm / Ø150 mm)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Installation instructions
19
Bellfires
English
RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION
POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm
Appliance: Concentric flue connection Ø100-Ø150 mm or Ø130-Ø200 mm
X
19
0.16 m
14
Wall
Termination
Position
10, 11, 13
Y
28
100
4
1
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance:
Distance Y
(min.-max.)
Distance X
(min.-max.)
Concentric
connection on
appliance is
Ø100-Ø150 mm
Concentric
connection on
appliance is
Ø130-Ø200 mm
1.0 - 2.0 m
0 - 0.6 m
-
-
2.0 - 3.0 m
0 - 1.6 m
-
-
Horizon Bell Small Tunnel 3
Figure 10: Horizontal wall termination
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
20
Installation instructions
Bellfires
English
RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION
POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm
Appliance: Concentric flue connection Ø130-Ø200 mm
X
19
100
0.16 m
14
Y
110, 111, 113
Wall
Termination
Position
128
4
1
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance:
Distance Y
(min.-max.)
Distance X
(min.-max.)
Concentric connection on
appliance is Ø130-Ø200 mm
0.5 - 1.0 m
0 - 0.6 m
-
1.0 - 2.0 m
0 - 2.6 m
-
Horizon Bell Small Tunnel 3
Figure 11: Horizontal wall termination
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Installation instructions
21
Bellfires
English
RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION
POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm
Appliance: Concentric flue connection Ø130-Ø200 mm
100
X
0.25 m
114
19
Wall
Termination
Position
110, 111, 113
Y
123
128
4
1
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance:
Distance Y
(min.-max.)
Distance X
(min.-max.)
Concentric connection on
appliance is Ø130-Ø200 mm
0.5 - 1.0 m
0 - 1.6 m
-
1.0 - 3.0 m
1.6 - 4.6 m
-
Horizon Bell Small Tunnel 3
Figure 12: Horizontal wall termination
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
22
Installation instructions
Bellfires
English
RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION
POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm
Appliance: Concentric flue connection Ø130-Ø200 mm
X2
19
100
0.16 m
14
Y2
110, 111,
113
110, 113
Wall
Termination
Position
114
114
X1
Y1
110, 111, 113
128
4
1
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance:
Distance Y1
(min.-max.)
Distance X1
(min.-max.)
Distance Y2
(min.-max.)
Distance X2
(min.-max.)
Concentric connection on
appliance is Ø130-Ø200 mm
0 - 0.5 m
0 - 0.5 m
0.5 - 1.0 m
0 - 0.6 m
-
Horizon
Bell
Small
0.5 - 1.0 m
0 - 0.5 m
0 - 0.5 m
0 - 0.6 m
-
Tunnel 3
1.0 - 3.0 m
0 - 1.0 m
0.5 - 2.0 m
0 - 0.6 m
-
1.0 - 3.0 m
0 - 3.0 m
1.0 - 3.0 m
0 - 0.6 m
-
Figure 13: Horizontal wall termination
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Installation instructions
23
Bellfires
English
RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION
POSSIBILITIES and with wall outlet Ø130 mm - Ø200 mm
Appliance: Concentric flue connection Ø130-Ø200 mm
X
0.25 m
114
119
Wall
Termination
Position
110, 111, 113
Y
123
128
4
1
Item descriptions:
see 1.6.2
Assemble restriction plate:
Appliance:
Horizon Bell Small Tunnel 3
Distance Y
(min.-max.)
Distance X
(min.-max.)
Concentric connection on
appliance is Ø130-Ø200 mm
0 - 0.5 m
0 - 0.6 m
-
0.5 - 3.0 m
0 - 3.6 m
-
1.0 - 3.0 m
3.6 - 8.6 m
-
Figure 14: Horizontal wall termination
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
24
Installation instructions
Bellfires
English
1.6.2 Item descriptions for figures 4 t/m 14
FIG. NO.
DESCRIPTION
1
Gas fire; Concentric flue connection Ø130/Ø200 mm or Ø100/Ø150 mm
2
-
3
-
4
Restriction plate (The different sizes restriction plates are supplied with every appliance)
5
Chimney, min. Ø150 mm internal, totally gas tight.
6
Chimney or fireproof sleeving. Min. Ø160 mm internal.
7
Ø100 mm internal flexible stainless steel gas vent chimney liner AISI 316TI.
8
Ø150 mm internal flexible stainless steel gas vent chimney liner AISI 316TI.
9
-
AVAILABLE COMPONENTS FOR THE BELLFIRES (M&G) CONCENTRIC
FLUE SYSTEM Ø100 mm - Ø150 mm
FIG.
NO.
BELLFIRES
ART. /
ORDER
NO.
10
302289
Twin-wall balanced flue pipe,
L = 500 mm, incl. • and ‚
l
l
11
302290
Twin-wall balanced flue pipe,
L = 1000 mm, incl. • and ‚
l
l
12
302291
Telescopic twin-wall balanced flue
pipe, L = min. 325 / max. 440 mm,
incl. • and ‚
l
l
13
302292
Adjustable length twin-wall
balanced flue pipe,
L = 500 mm, incl. • and ‚
l
l
14
302297
Twin-wall balanced flue elbow 90°,
incl. • and ‚
l
l
Color(*)
Application
DESCRIPTION
RVS antr. RIGID FLEX
Installation instructions
25
Bellfires
English
FIG.
NO.
BELLFIRES
ART. /
ORDER
NO.
15
302298
Twin-wall balanced flue elbow 45°,
incl. • and ‚
l
16
302295
Vertical (roof) termination kit,
L = 1360 mm (vertical),
incl. •, ‚ and „
l
17
302212
Adjustable roof flashing.
Roof pitch 20° - 45° (**),
with lead flashing
18
302213
19
Color(*)
Application
DESCRIPTION
RVS antr. RIGID FLEX
l
l
l
l
l
l
Roof flashing for existing chimney
or flat roof
l
l
l
302296
Horizontal (wall) termination kit,
L = 600 mm (horizontally adjustable)),
incl. •, ‚ and one set of wall spacer
plates
l
l
l
20
302293
• : Stainless steel locking band
Ø150 mm, quick-fastening
l
l
l
21
302210
‚ : Silicone seal Ø150 mm
l
l
23
302215
„ : Wall strap
l
l
l
24
302214
Set of ceiling finishing plates /
Fire stops
l
l
l
26
l
l
Installation instructions
Bellfires
FIG.
NO.
English
BELLFIRES
ART. /
DESCRIPTION
ORDER
NO.
Color(*)
Application
RVS antr. RIGID FLEX
25
302189
Ceiling plate for transition
Ø100 mm / Ø150 mm rigid Ø100 mm (flex.).
l
26
302278
Stainless steel adapter piece (100)
from fire to flexible, Ø100 mm
external (rigid) x Ø107 mm internal
(flex.).
[appliance - Ø100 mm flex.] and
[Ø100 mm rigid - Ø100 mm flex.].
l
l
27
302279
Stainless steel adapter piece (150)
fire to flexible, Ø148 mm external
(rigid) x Ø148 mm internal (flex.)
[appliance - Ø150 mm flex.].
l
l
28
302217
Stainless steel locking band Ø150 mm.
For adapter 150 [appliance - Ø150
mm (flex.)], Screw-fastening
l
29
303776
Stainless steel screws Ø3.5 mm x
9.5 mm. For securing the flexible
concentric flue. (Minimum 3 screws
per connection)
l
l
30
304041
Hose clamp Ø100 mm.
(Minimum 2 per connection)
l
l
31
304042
Hose clamp Ø150 mm.
(Minimum 2 per connection)
l
l
32
302307
Vertical (roof) termination kit,
L = 610 mm (vertical), incl. • and ‚.
For the flexible flue system.
l
33
302301
Concentric T-piece with gauging
orifice, incl. • and ‚
l
Installation instructions
l
l
l
l
l
l
l
l
27
Bellfires
English
FIG.
NO.
BELLFIRES
ART. /
ORDER
NO.
34
302302
Concentric pipe with gauging
orifice, L = 165 mm,
incl. • and ‚
l
l
35
302303
90° concentric bend with
inspection panel,
incl. • and ‚
l
l
36
321948
Universal wall / floor support
Ø150 mm
l
l
Color(*)
Application
DESCRIPTION
RVS antr. RIGID FLEX
(*) : Color : RVS : Stainless steel self-colour, polished
antr. : Anthracite colour lacquer, matt
(**) : Adjustable roof flashing for a slope > 45° can be supplied on request.
When installing a balanced-flue “closed” gas fire in an existing chimney, ensure stainless
steel flexible liners (Ø100 mm or Ø130 mm) conforming with BS 316 are used to conduct
the spent gases.
28
Installation instructions
Bellfires
English
AVAILABLE COMPONENTS FOR THE BELLFIRES (M&G) CONCENTRIC
FLUE SYSTEM Ø130 mm - Ø200 mm
FIG
NO.
BELLFIRES
ART. /
ORDER
NO.
100
302319
Concentric reduction of
Ø130 / Ø200 mm
Ø100 / Ø150 mm
l
l
110
302308
Twin-wall balanced flue pipe,
L= 500 mm, incl. … and †
l
l
111
302309
Twin-wall balanced flue pipe,
L= 1000 mm, incl. … and †
l
l
113
302310
Adjustable length twin-wall
balanced flue pipe,
L= 500 mm, incl. … and †
l
l
114
302314
Twin-wall balanced flue elbow 90°,
incl. … and †
l
l
115
302315
Twin-wall balanced flue elbow 45°,
incl. … and †
l
l
119
302313
Horizontal (wall) termination kit,
L= 600 mm (horizontally
adjustable), incl. …, † and one set
of wall spacer plates
l
Color(*)
Application
DESCRIPTION
RVS antr. RIGID FLEX
Installation instructions
l
l
l
29
Bellfires
English
FIG.
NO.
BELLFIRES
ART. /
ORDER
NO.
120
302311
… : Stainless steel locking band
Ø200 mm, quick-fastening
121
302248
123
Color(*)
Application
DESCRIPTION
RVS antr. RIGID FLEX
l
l
† : Silicone seal Ø200 mm
l
l
302251
ˆ : Wall strap
l
l
124
302250
Set of ceiling finishing plates /
Fire stops
l
l
l
126
302281
Stainless steel adapter piece (130)
from fire to flexible, Ø130 mm
external (rigid) x Ø137 mm internal
(flex.), [appliance - Ø130 mm flex.]
and [Ø130 mm rigid - Ø130 mm flex.]
l
l
127
302282
Stainless steel adapter piece (200)
from fire to flexible, Ø198 mm
external (rigid) x Ø198 mm internal
(flex.), [appliance - Ø200 mm flex.]
l
l
128
302257
Stainless steel locking band Ø200
mm. For adapter 200. [appliance Ø200 mm flex.]. Screw-fastening
l
129
303776
Stainless steel screws Ø3.5 mm x
9.5 mm. For securing the flexible
concentric flue. (Minimum 3 screws
per connection)
l
l
130
304045
Hose clamp Ø130 mm.
(Minimum 2 per connection)
l
l
131
304046
Hose clamp Ø200 mm.
(Minimum 2 per connection)
l
l
30
l
l
l
Installation instructions
Bellfires
English
AVAILABLE COMPONENTS FOR THE POUJOULAT PGI CONCENTRIC
FLUE SYSTEM Ø100 mm - Ø150 mm
FIG.
NO.
POUJOULAT
ART. /
ORDER
NO.
DESCRIPTION
37100403
Twin-wall balanced flue pipe,
L = 250 mm
10
37100404
Twin-wall balanced flue pipe,
L = 450 mm
11
37100405
Twin-wall balanced flue pipe,
L = 950 mm
12
37100429
Telescopic twin-wall balanced flue pipe,
L = min. 390 mm / max. 640 mm
14
37100441
Twin-wall balanced flue elbow 90°
15
37100421
Twin-wall balanced flue elbow 45°
Installation instructions
31
Bellfires
FIG.
NO.
32
English
POUJOULAT
ART. /
ORDER
NO.
DESCRIPTION
37100411
Twin-wall balanced flue elbow 30°
37100401
Twin-wall balanced flue elbow 15°
16
37100654
Vertical (roof) termination kit,
L = 140 mm
17
45150171
Roof flashing, suitable for a brick roof,
with a roof pitch of 15°- 30°
45150170
Roof flashing, suitable for a tiled roof,
with a roof pitch of 15°- 30°
45150172
Roof flashing, suitable for a brick roof,
with a roof pitch of 30°- 45°
45150173
Roof flashing, suitable for a tiled roof,
with a roof pitch of 30°- 45°
Installation instructions
Bellfires
English
FIG.
NO.
POUJOULAT
ART. /
ORDER
NO.
18
45150169
Roof flashing for existing chimney
or flat roof
19
37100610
Horizontal (wall) termination kit,
L = min. 365 mm / max. 585 mm
20
45150076
Stainless steel locking band Ø150 mm,
quick-fastening
23
45150072
Wall strap, Ø150 mm
24
37100442
Ceiling/wall plate with spacers and
ventilation grooves
37100425
Set of ceiling finishing plates / Fire stops,
suitable for a roof pitch of 0°- 10°
37100426
Set of ceiling finishing plates / Fire stops,
suitable for a roof pitch of 10°- 30°
37100427
Set of ceiling finishing plates / Fire stops,
suitable for a roof pitch of 30°- 40°
37100428
Set of ceiling finishing plates / Fire stops,
suitable for a roof pitch of 40°- 50°
37100407
Concentric pipe with inspection opening,
L = 250 mm
34
Installation instructions
DESCRIPTION
33
Bellfires
34
English
FIG.
NO.
POUJOULAT
ART. /
ORDER
NO.
36
45150165
Roof support, (universal) Ø150 mm
36
45150081
Floor support, (universal) Ø150 mm
37
37100611
Adapter: Bellfires Ø100-150 mm
Poujoulat PGI Ø100-150 mm
(Appliance 100/150
Poujoulat PGI
100/150)
100
37100614
Adapter: Bellfires Ø130-200 mm
Poujoulat PGI Ø100-150 mm
(Appliance 130/200
Poujoulat PGI
100/150)
101
37100613
Concentric reduction of
Poujoulat PGI Ø130-200 mm
Poujoulat PGI Ø100-150 mm
DESCRIPTION
Installation instructions
Bellfires
English
AVAILABLE COMPONENTS FOR THE POUJOULAT PGI CONCENTRIC
FLUE SYSTEM Ø130 mm - Ø200 mm
FIG.
NO.
POUJOULAT
ART. /
ORDER
NO.
DESCRIPTION
37130403
Twin-wall balanced flue pipe,
L = 250 mm
110
37130404
Twin-wall balanced flue pipe,
L = 450 mm
111
37130405
Twin-wall balanced flue pipe,
L = 950 mm
112
37130429
Telescopic twin-wall balanced flue pipe,
L = min. 390 mm / max. 640 mm
114
37130441
Twin-wall balanced flue elbow 90°
115
37130421
Twin-wall balanced flue elbow 45°
Installation instructions
35
Bellfires
FIG.
NO.
36
English
POUJOULAT
ART. /
ORDER
NO.
DESCRIPTION
37130411
Twin-wall balanced flue elbow 30°
115
37130401
Twin-wall balanced flue elbow 15°
119
37130610
Horizontal (wall) termination kit,
L = min. 425 mm / max. 585 mm
120
45200076
Stainless steel locking band Ø200 mm,
quick-fastening
123
45200072
Wall strap, Ø200 mm
124
37130442
Ceiling/wall plate with spacers and
ventilation grooves
37130425
Set of ceiling finishing plates / Fire stops,
suitable for a roof pitch of 0°- 10°
37130426
Set of ceiling finishing plates / Fire stops,
suitable for a roof pitch of 10°- 30°
37130427
Set of ceiling finishing plates / Fire stops,
suitable for a roof pitch of 30°- 40°
37130428
Set of ceiling finishing plates / Fire stops,
suitable for a roof pitch of 40°- 50°
Installation instructions
Bellfires
FIG.
NO.
English
POUJOULAT
ART. /
ORDER
NO.
DESCRIPTION
37130407
Concentric pipe with inspection opening,
L = 250 mm
45200165
Roof support, (universal) Ø200 mm
45200081
Floor support, (universal) Ø200 mm
37130615
Adapter: Bellfires Ø130-200 mm
Poujoulat PGI Ø130-200 mm
(Appliance 130/200
Poujoulat PGI
130/200)
Installation instructions
37
Bellfires
English
AVAILABLE COMPONENTS FOR THE ONTOP METALOTERM US CONCENTRIC
FLUE SYSTEM Ø100 mm - Ø150 mm
FIG.
NO.
ONTOP
ART. /
ORDER
NO.
USA 10
38
DESCRIPTION
Adapter for Bellfires appliances with Ø100-Ø150 mm
concentric connection
US 25 10
Twin-wall balanced flue pipe, L = 250 mm
10
US 50 10
Twin-wall balanced flue pipe, L = 500 mm
11
US 100 10
Twin-wall balanced flue pipe, L = 1000 mm
12
USPP 10
14
USB 90 10
Twin-wall balanced flue elbow 90°
15
USB 45 10
Twin-wall balanced flue elbow 45°
USB 30 10
Twin-wall balanced flue elbow 30°
Telescopic twin-wall balanced flue pipe,
L = min. 60 / max. 250 mm
Installation instructions
Bellfires
FIG.
NO.
English
ONTOP
ART. /
ORDER
NO.
USB 15 10
DESCRIPTION
Twin-wall balanced flue elbow 15°
16
USDVC2 10
16
USSR 10
Storm collar Ø150 mm
17
USLS 10
Adjustable roof flashing.
Roof pitch 20° - 45° (**), with lead flashing
17
USDH 10
Roof flashing plate for roof pitch 5°- 30°
18
USDP 10
Roof flashing for existing chimney
or flat roof
18
USDPAL 10
Roof flashing - Aluminium for existing chimney
or flat roof
19
USDHC5 10
Horizontal (wall) termination kit,
L = 475 mm (horizontally adjustable)),
incl. ‚
Installation instructions
Vertical (roof) termination kit,
L = 375 mm, incl. •
39
Bellfires
40
English
FIG.
NO.
ONTOP
ART. /
ORDER
NO.
DESCRIPTION
20
USKB 10
• : Locking band, quick-fastening
21
USAB 10
‚ : Cover band, screw-fastening
23
USMB 10
Wall strap, adjustable
23
USEB 10
Fitting bracket
24
USCP 10
Set of ceiling finishing plates / Fire stops /
Centring plates
24
USDQ 10
Roof support
25
USSAN 10
Renovation set
25
USSAN1 10
Top of renovation set
Installation instructions
Bellfires
English
FIG.
NO.
ONTOP
ART. /
ORDER
NO.
25
USSAN2 10
28
USKBS 10
USI 10
DESCRIPTION
Bottom renovation set
Locking band, screw-fastening
Concentric pipe with inspection panel,
L = 250 mm
34
USEM 10
Concentric pipe with gauging orifice,
L = 150 mm
35
USBI 10
90° concentric bend with inspection panel
USR 10
Rosette smooth Ø150 mm
USMPG 10
Wall plate large Ø150 mm,
ASAH 10
Installation instructions
300 mm
Spacer bracket
41
Bellfires
FIG.
NO.
English
ONTOP
ART. /
ORDER
NO.
USVG 10 13
DESCRIPTION
Concentric reduction of Ø100-Ø150 mm
Ø130-Ø200 mm
AVAILABLE COMPONENTS FOR THE ONTOP METALOTERM US CONCENTRIC
FLUE SYSTEM Ø130 mm - Ø200 mm
FIG.
NO.
ONTOP
ART. /
ORDER
NO.
USA 13
42
DESCRIPTION
Adapter for Bellfires appliances with Ø130-Ø200 mm
concentric connection
US 25 13
Twin-wall balanced flue pipe, L = 250 mm
10
US 50 13
Twin-wall balanced flue pipe, L = 500 mm
11
US 100 13
Twin-wall balanced flue pipe, L = 1000 mm
12
USPP 13
14
USB 90 13
Telescopic twin-wall balanced flue pipe,
L = min. 60 / max. 250 mm
Twin-wall balanced flue elbow 90°
Installation instructions
Bellfires
English
FIG.
NO.
ONTOP
ART. /
ORDER
NO.
15
USB 45 13
Twin-wall balanced flue elbow 45°
USB 30 13
Twin-wall balanced flue elbow 30°
USB 15 13
Twin-wall balanced flue elbow 15°
DESCRIPTION
16
USDVC2 13
16
USSR 13
Storm collar Ø150 mm
17
USLS 13
Adjustable roof flashing.
Roof pitch 20° - 45° (**), with lead flashing
17
USDH 13
Roof flashing plate for roof pitch 5°- 30°
Installation instructions
Vertical (roof) termination kit,
L = 375 mm, incl. •
43
Bellfires
44
English
FIG.
NO.
ONTOP
ART. /
ORDER
NO.
18
USDP 13
18
USDPAL 13
Roof flashing - Aluminium for existing chimney
or flat roof
19
USDHC4 13
Horizontal (wall) termination kit,
L = 475 mm (horizontally adjustable)),
incl. ‚
20
USKB 13
• : Locking band, quick-fastening
21
USAB 13
‚ : Cover band, screw-fastening
23
USMB 13
Wall strap, adjustable
23
USEB 13
Fitting bracket
24
USCP 13
Set of ceiling finishing plates / Fire stops /
Centring plates
DESCRIPTION
Roof flashing for existing chimney
or flat roof
Installation instructions
Bellfires
English
FIG.
NO.
ONTOP
ART. /
ORDER
NO.
24
USDQ 13
Roof support
25
USSAN 13
Renovation set
25
USSAN1 13
Top of renovation set
25
USSAN2 13
Bottom renovation set
28
USKBS 13
USI 13
34
USEM 13
Installation instructions
DESCRIPTION
Locking band, screw-fastening
Concentric pipe with inspection panel,
L = 250 mm
Concentric pipe with gauging orifice,
L = 150 mm
45
Bellfires
English
FIG.
NO.
ONTOP
ART. /
ORDER
NO.
DESCRIPTION
35
USBI 13
90° concentric bend with inspection panel
USR 13
Rosette smooth Ø200 mm
USMPG 13
Wall plate large Ø200 mm,
ASAH 13
USVG 13 10
350 mm
Spacer bracket
Concentric reduction of Ø130-Ø200 mm
Ø100-Ø150 mm
• The room-sealed gas appliances have been approved in combination
with the components of the concentric flue systems listed in this
instruction book, according to the European CE norm for gas appliances
and may therefore be used only with these components.
• The components of the concentric flue system of Bellfires (M&G system),
Poujoulat (PGI system) and Ontop (Metaloterm US system) may
not be used together in one installation.
• Check whether the wall or roof termination kit to be used exactly
matches one of those listed in this instruction book.
46
Installation instructions
Bellfires
English
1.6.3 Gas connection
Operation (gas regulating block (and receiver)) outside the appliance (in the operating unit):
The gas connection is situated where the operating unit is built in near to the appliance.
Use only gas piping with a minimum diameter of 1/2” and a shut-off valve.
1.6.4 Operating unit
If the appliance is fitted with an operating unit comprising gas control block and receiver,
this will be located, once it has been built in, at a maximum of 50 cm from the left or
right hand side of the appliance.
1.6.5 Convection package connections
When fitting a convection package (= convection top plate and convection set (1x or
2x)), consideration should be given to the openings at approximately 1 meter above the
appliance for the warm air exiting grids.
1.7 POSITIONING THE APPLIANCE
Important:
The fireplace is constructed on a sufficiently solid floor that
can bear the weight of the appliance.
Ensure a free space of at least 1 cm between the bottom of
the appliance and the floor.
Min.1 cm
Ensure that the temperature of the floor under and in front of
the appliance can never rise above 85°C!
Make use of a temperature protection plate (of nonflammable
material) on the floor if necessary.
Take care with a floor made of a flammable material.
Figure 15: A clearence of at least 1 cm must be maintained between
the bottom of the appliance and the floor.
Installation instructions
47
Bellfires
English
The walls of the chimney must be made of nonflammable
material.
Never use combustible materials during the installation.
Make an air gap of at least 5 cm in the chimney breast,
left and right of the gas fire.
Ventilate the fireplace, by allowing vents above and
below the fireplace.
During installation of the gas fire, a clearance of 3 mm
should be maintained on all sides of the appliance to
allow for expansion of the appliance during operation.
Do not insulate the appliance! Only the top and sides
may be fitted with a strip of white, loose insulation wool
(heat-resistant to 1000°C), width 15 cm max. to protect
the wall.
Do not use fibreglass or Rockwool, or any other sort of
insulating material. These emit a pungent odour.
This is considered extremely unpleasant. They may also
cause discolouring of the column.
Flammable materials, such as curtains, should not
be placed in the vicinity of the gas fire.
Minimum safe distance: 100 cm.
If desired, fit a convection package to the appliance.
(See chapter 1.1)
The appliance can be easily installed using a set of
carrying brackets (accessory).
After installing: remove carrying brackets!
48
Installation instructions
Bellfires
Figure 16:
1
2
3
4
5
6
7
8
9
10
English
Appliance installed in ventilated chimney breast
Horizontal outlet of the flue gas exhaust /combustion air
supply via the wall.
Fitted with the options / accessories:
• convection package (= convection top plate and 1x convection set)
• 1x extra convection set
• high adjustable feet
Inlet opening (appliance) convection air
Inlet opening (grate) (chimney breast) convection air
Natural convection in the chimney breast
Outlet opening (grate) (chimney breast) natural convection air
Outlet opening (appliance) convection air / connection convection set (2x or 4x)
Outlet opening (grill convection set) (chimney breast) convection air (2x or 4x)
Concentric flue connection appliance; Ø130-200 mm for a horizontal wall outlet
Horizontal wall outlet
Built in operating unit with gas regulating block and receiver
Installation instructions
49
Bellfires
Figure 17:
1
2
3
4
5
6
7
50
English
Appliance installed in ventilated chimney breast
Vertical outlet of the flue gas exhaust / combustion air
supply via the roof.
Fitted without convection package
Inlet opening (appliance) convection air
Inlet opening (grate) (chimney breast) convection air
Natural convection in the chimney breast
Outlet opening (grate) (chimney breast) convection air (2x)
Concentric flue connection appliance; Ø100-150 mm for a vertical roof outlet
Concentric flue system; Ø100-150 mm for a vertical roof outlet
Built in operating unit with gas regulating block and receiver
Installation instructions
Bellfires
English
When fitting the appliance, it can be levelled with the adjustable feet.
These adjustable feet can be reached via the openings (4x), after removing the protective covers, in the corners of the floor of the combustion chamber.
The floor of the combustion chamber can be reached after the window and the grill
around the burner have been removed (see chapter 4).
Using an Allenkey (no. 5), the appliance can be adjusted to the required height.
Press the 4 protecting covers back into the floor.
•
‚
ƒ
„
- Position 4 protecting covers.
- Adjustable feet seen from the bottom
of the appliance.
Installation instructions
- Protecting cover.
- Adjust height with Allenkey no. 5.
51
Bellfires
English
Position the gas supply pipe such that it can be easily mounted after installation.
Because the control system is outside the appliance, the gas pipe must lead to where
the operating unit (built in), the gas regulating block (and the receiver) assembly are
fitted.
The appliance may not be installed in a flammable wall.
Attach the appliance to the side walls with 2 wedge bolts. Use the adjustable mounting
brackets at the top of the appliance for this.
- 2x Mounting bracket.
52
Installation instructions
Bellfires
English
1.7.1 Gas connection operating unit
Important:
During gas connection, take care not to twist the gas
regulator block. Make sure that both the gas regulator
block and the supply pipes are not subjected to stresses.
The appliance is supplied with a built-in operating unit.
Operating unit
Frame with
door (white)
Figure 18: Operating unit
Remove the decorative edging and door of the operating unit.
Fit the separate operating unit, where the gas regulator block and receiver will be
placed, on max. 50 cm from the appliance.
The burner, gas regulator block and receiver have been fully factory assembled.
Disconnect the bracket with the gas regulator block and receiver from the appliance.
Carefully move the bracket with the gas regulator block, receiver, pipes and cables to
the operating unit. Mount the bracket at the bottom of the operating unit..
Important:
Take care that no pipes get damaged and no compression fittings
come loose when moving the gas regulator block. Prevent twisting
the flexible pipes! Check all compression fittings for leaks
afterwards!
Mount the receiver in the top of the operating unit. Check afterwards that all electric
connections are properly connected.
General:
Route all piping and cables from the operating unit to the appliance through an easily
accessible hollow cavity.
During subsequent installation of the operating unit, protect the gas regulator block and
piping against encasement by cement etc.
Installation instructions
53
Bellfires
Important :
English
Cement and chalk can damage
the piping and can, in turn,
lead to gas leaks.
Disassembly and assembly of pipes and cables:
If necessary for mounting, all pipe compression fittings and cable connectors can be
temporarily disassembled. After mounting, carefully reassemble all pipes and cables.
Check afterwards all compression fittings for leaks and that all electric connections are
properly connected.
Important :
Note :
Screw the thermocouple connection (and thermocouple
interrupter) manually into the gas regulator block. Afterwards,
carefully fasten a half turn with a spanner.
Check that the flexible burner pipes are correctly connected!
The gas connection of the gas valve “rear burner” must be
connected to the “rear burner”! See Chapter 5. Switching over the
flexible burner pipes during assembly can lead to an explosive
ignition. Prevent this at all costs!
Gas pipe
“rear burner”
Ø8 mm Flex.
Thermocouple
Pilot light pipe
Ø4 mm Flex.
Thermocouple
interrupter
Gas valve
“rear burner”
Gas pipe
“front burner”
Ø8 mm Flex.
Gas supply
connection
Gas regulator block
Figure 19: Gas regulator block and gas valve: Gas and thermocouple connections
54
Installation instructions
Bellfires
English
Pilot Gas Adjustment Screw
(Pierce the housing with
a small screwdriver)
Adjustment Screw
Maximum
Burner pressure
Motor-knob
8 Wire connecting
cable receiver
Microswitch
Figure 20: Gas regulator block - Front
Adjustment
Screw
Minimum
Burner pressure
Inlet
Pressure Tap
Outlet
Pressure Tap
Pilot light
connection
Thermocouple
interrupter
connection
Gas supply
connection
Gas connection for
to the “front burner”
Gas connection for gas valve
to the “rear burner”
Figure 21: Gas regulator block - Rear
Installation instructions
55
Bellfires
English
Piezo cable
connection
Thermocouple
voltage / current
OUT - connection (yellow)
Thermocouple
voltage / current
IN - connection (red)
SW
TC
Connection
8 wire cable
gas regulator block
Connection for
external operating
(option)
AUX:
Electrical
connection
for gas valve
“rear burner”
6 VDC Adapter
connection
(option)
RESET button
Figure 22: Receiver - Top
RESET button
AUX:
Electrical
connection
for gas valve
“rear burner”
Figure 23: Receiver - AUX connection - RESET button
56
Installation instructions
Bellfires
English
1.7.2 Connecting the concentric flue
Assemble the concentric flue system according to one of the examples in section 1.6.1,
figure 4 to 14 inclusive.
Make sure that all connections are completely gas tight.
1.7.3 Building in the appliance
Remove the front of the casing, if applicable. (See Chapter 4: Dismantling / Assembling
of the glass.)
Decide on positions of the vents (grilles above and below the fireplace) and, if
applicable, the hot air grids of the convection package.
The brickwork must be built up around the hearth. In connection with the hearth
expanding during burning: there must be at least 3 mm clearance on either side of the
appliance. Do not build up the brickwork farther than the angle irons/brackets (keep in
mind the thickness of any plastering!).
Do not use masking tape on the appliance when installing
and plastering.
Tape can damage the finish of the hearth.
Connect up the convection package, if applicable.
The optional mantle iron is intended for supporting the brickwork above the hearth.
The mantle iron must rest on the brickwork on both sides so that upward building is
possible. The brickwork therefore must not rest on the fireplace; there must be approx.
3 mm clearance in connection with the weight.
If using other materials, such as stone or heat-resistant plating, you should follow the
supplier’s instructions.
Once the fireplace has been finished, you can now, fit the frame with the small door to
the operating unit.
After installation in a new fireplace and/or applying new cement work, the
appliance cannot be used for at least four weeks.
Installation instructions
57
Bellfires
English
1.7.4 Checking the gas connection
After connection of the gas supply, check that all connections are completely gas tight
using soapy water or a leak tester.
1.7.5 Positioning the ceramic log set or marble pebbles
The appliance can be supplied with:
• Ceramic log set + embers
• Marble pebbles white (small, white marble stones)
• Marble pebbles grey (small, grey marble stones)
Important:
• Carefully place the chips of wood/embers/vermiculite granules/
log set or marble pebbles, on and around the main burner
according to the directions in this chapter.
• Do not place any chips of wood/embers/vermiculite granules/
log set or marble pebbles against the pilot light burner.
For that reason, the main burner has a protective pilot-light cowl.
Never remove this cowl! Make sure that the pilot flame can burn
at all times freely over the main burner. Only in this way is
proper ignition of the main burner ensured.
Ignoring these directions could lead to a dangerous situation.
• Make sure that all burner orifices remains free at all times!
• The burner bed (with chips of wood/embers/vermiculite
granules) and the positioning of the logs or marble pebbles
must not be changed.
• Only use those items supplied! These been rigorously
checked and the quantities adapted to the appliance.
• Replacement parts, including the ceramic mat are available
from your dealer.
• Fitting may only be carried out by a qualified person.
Remove the glass according to the instructions in chapter 4; DISMANTLING /
ASSEMBLING OF THE GLASS.
58
Installation instructions
Bellfires
1.7.5.1
English
Ceramic log set + chips of wood + embers + vermiculite granules
1 Place the ceramic mat on the burner in such a way that the holes in the mat are in
line with the burner openings.
2 Remove the embers carefully from their packaging and spread them evenly over the
burner mat and the grate around the burner.
3 Distribute the vermiculite granules (50 gram) evenly over the burner.
Installation instructions
59
Bellfires
Note ! :
English
•
•
•
Small embers and their residue should not be scattered on
the burner. This can cause a blockage on the burner orifices.
Embers and vermiculite granules must not be placed next to
the pilot light burner.
Important: make sure that all burner openings remain free !!
Burner orifices, which are not open, could lead to a dangerous
situation.
4 Place the logs on the burner:
Appliance
Natural gas-burner
see figure:
Horizon Bell Small Tunnel 3 CF/LF
24
Propane / Butane-burner
see figure:
25
Keep the burner orifices unblocked !!!
5 Place the chips of wood around the burner.
60
Installation instructions
Bellfires
English
Logs:
Log no u
Log no v
Log no w
Log no x
Log no y
Log no z
Log no {
Log no |
Installation instructions
61
Bellfires
English
v
|
w
y
u
v
z
x
Embers must not be placed next to the pilot light burner
Keep the burner orifices unblocked!
Figure 24:
Log set Horizon Bell Small Tunnel 3 CF/LF
Position natural gas burner
v
|
w
z
y
u
v
x
Embers must not be placed next to the pilot light burner
Keep the burner orifices unblocked!
Figure 25:
62
Log set Horizon Bell Small Tunnel 3 CF/LF
Position propane/butane burner
Installation instructions
Bellfires
English
1.7.5.2 Marble pebbles
1 Place the ceramic mat on the burner in such a way that the holes in the mat are in
line with the burner openings.
2 Spread the pebbles over the whole burner bed (burner and grid around the burner).
Make sure that the pilot light remains free.
Horizon Bell Small Tunnel 3 CF/LF
Keep the burner
orifices unblocked
:
see figure 27
IMPORTANT: Open area, in order to ensure free
accessibility of the pilot flame to the burner
Figure 26: Marble pebbles-set natural gas and propane/butane-burner
Installation instructions
63
Bellfires
English
Keep the burner
orifices unblocked!
Marble pebbles must not be placed
next to the pilot light burner
Keep the burner orifices unblocked!
Figure 27:
Important:
Marble pebbles Horizon Bell Small Tunnel 3 CF/LF
Position natural gas and propane/butane burner
•
•
Do not place any marble pebbles in front of the pilot light.
Make sure that the pilot light can burn freely over the main
burner.
Keep the burner orifices unblocked.
Only this way a proper ignition of the main burner is ensured.
Once the logs / marble pebbles have been positioned, replace the glass in the appliance,
following the instructions in chapter 4: DISMANTLING / ASSEMBLING OF THE
GLASS.
1.7.6 Mounting flue gas restriction plate
Depending on the length and shape of the concentric flue system and the chimney
construction, you should, if indicated, fit a restriction plate with a certain width (B) into
the ceiling of the combustion chamber.
To do this, see the set-up options as listed in figure 4 through 14.
64
Installation instructions
Bellfires
Important:
English
Ensure that the correct flue gas restriction plate is mounted.
Use of the correct flue gas restriction plate will provide
optimum efficiency, flame effect and combustion. Mounting
an incorrect flue gas restriction plate can result in damage
to the gas fire.
Assembly
restriction
plate
Figure 28: Positioning restriction plate
Installation instructions
65
Bellfires
English
The following restriction plates are supplied:
%
[
Concentric flue connection appliance
Restriction plate:
Width:
Width:
Width:
Width:
Width:
[Ø130 - 200 mm]
Horizontal wall outlet
B = 40 mm
B = 50 mm
B = 65 mm
B = 80 mm
[Ø100 - 150 mm]
Roof-mounted outlet
B = 30 mm
B = 40 mm
B = 50 mm
B = 65 mm
-
1.7.7 Checking the appliance following installation
After installation, visually check the gas flame. When the fire is ignited, the flames
should be short and blue/yellow in colour. These flames should gradually increase in
height and become more yellow. When all flames are yellow, the gas fire has reached
the correct temperature.
THE GAS FIRE IS NOW READY FOR USE
66
Installation instructions
Bellfires
2
English
MAINTENANCE
2.1 ANNUAL MAINTENANCE
It is essential that the appliance, the complete concentric
flue system (where possible) and the outlet are cleaned and
inspected annually by a recognised fitter/gas specialist.
The safe operation of the appliance will thus remain
guaranteed.
Maintenance consists of the following:
• Remove first the embers, vermiculite granules, logs set or pebbles from the main
burner and carefully clean these with a soft brush.
• Clean and inspect (visually) the main burner, pilot light, combustion chamber,
flue system and combustion air intake. Dust can be removed using a vacuum
cleaner.
• Clean the glass on the inside of the appliance with glass spray or ceramic hob
cleaner. This also applies to the black mirror side panels, if the appliance is fitted
with these.
• After cleaning;
Carefully replace the embers, vermiculite granules, logs set or pebbles on and
around the main burner according to the installation directions in this instruction
booklet.
Do not place any embers, vermiculite granules, logs or pebbles against the
pilot light burner. Make sure that the pilot flame can burn at all times freely over
the main burner. Only in this way is proper ignition of the main burner ensured.
Ignoring these directions could lead to a dangerous situation.
• Check the gas supply, flue system, and combustion air supply route for leaks.
• Check the correct operation of the gas regulating block, thermocouple
circuit and the ignition of the main burner.
• Check the gas inlet-pressure (both when the appliance is off and when it burns
at maximum) and the burner pressure.
• Check the complete concentric flue system including the outlet construction.
A camera can be used to inspect the whole length of the flue gas outlet and the
combustion air intake.
Also check that all connections are secure.
Installation instructions
67
Bellfires
3
FAULTS
3.1
POSSIBLE REASONS
English
Possible reasons for the gas fire going out are:
• The concentric flue system is not installed according to one of the methods detailed
in Paragraph 1.6.
• An incorrect “flue gas restriction plate” is fitted.
• The pilot light extinguishes if fumes are not exhausted or are insufficiently
exhausted.
• The pilot light is either dirty or defective.
• Insufficient gas pressure.
• (Internal) leak of the concentric flue system.
• Thermocouple voltage is too low. This is usually caused by insufficient heating of the
thermocouple by the pilot light.
• Dirty electrical contacts in the thermo-electrical system; for example, the
thermocouple connection.
• Batteries in receiver or remote control are flat.
3.2
SAFETY MEASURES IN THE APPLIANCE
3.2.1
Thermo-electric pilot light shut off
The appliance is protected by means of a thermo-electric pilot light shut off in the event
of a gas escape from the main burner.
3.2.2
Over pressure safety system
The appliance is fitted with a patented safety system, whereby the door will extract any
over-pressure that arises in a controlled way. In this, a spring system briefly causes the
door to hinge forward a few centimetres. A loud noise can occur.
A safety strip limits the maximum degree to which the door can be tilted.
This applies to both doors!
If an over-pressure situation occurs, the appliance should be thoroughly checked by the
installer.
68
Installation instructions
Bellfires
4
English
DISMANTLING / ASSEMBLING OF THE GLASS
4.1 HORIZON BELL SMALL TUNNEL 3 FLOATING FRAME
Dismantling of the glass:
- Horizon Bell Small Tunnel 3
Floating Frame
- Use the hook supplied (see photo) for
opening the frame and the glass.
Note ! :
When loosening the frame and
after it has been loosened, support it with your hand to prevent
it falling forward !
- With the hook, pull the thin, metal
spring strips on the top left and
right from the studs on the frame.
Installation instructions
69
Bellfires
English
stud (right)
- Detail of the stud (right).
- Place paperboard on the chimney
breast, under the frame. This helps
prevent damage.
- Dismantle the safety strip from the frame.
70
Installation instructions
Bellfires
- Carefully tilt the frame and the window
forwards.
Note ! : Frame and window are
two separate parts !
English
- Take hold of the frame and the glass
clamped together and pull these
upwards.
- Frame and glass are now removed from the appliance.
Assembling of the glass:
The assembly of the glass takes place in reverse order.
Important:
• Check whether the frame is properly positioned underneath in the 2 holes of the front.
• Check whether the frame is placed in the middle of the front.
• Check whether the safety strip is securely fastened to the top of the frame (middle).
• The glass (frame) must fit tightly all round to the edge of the combustion chamber.
• Check that the spring strips, on the top, remain in their proper place.
Installation instructions
71
Bellfires
English
4.2 HORIZON BELL SMALL TUNNEL 3 HIDDEN DOOR
Dismantling of the glass:
- Horizon Bell Small Tunnel 3 Hidden Door.
- Use the hook supplied for opening
the frame (including glass).
- Use the hook to pull the frame at the top forward and hold the frame firmly.
72
Installation instructions
Bellfires
English
- With the hook, pull the thin, metal spring strips on the top left and right from the studs
on the frame.
- Dismantle the safety strip from the frame.
Note ! :
When loosening the frame and after it
has been loosened, support it with your
hand to prevent it falling forward !
Installation instructions
73
Bellfires
English
- Carefully tilt the frame and the glass forwards
at the top.
Prevent damage by laying paperboard on the
chimney breast, under the frame.
Pull the frame upwards and remove it from
the appliance.
Assembling of the glass:
The assembly of the glass takes place in reverse order.
Important:
• Check whether the frame is properly positioned underneath in the 2 holes of the front.
• Check whether the frame is placed in the middle of the front.
• Check whether the safety strip is securely fastened to the top of the frame.
• The glass (frame) must fit tightly all round to the edge of the combustion chamber.
• Check that the spring strips, on the top, remain in their proper place.
74
Installation instructions
Bellfires
5
English
DIAGRAM ELECTRICITY AND GAS
Double burner:
: Perforation pattern “Centre Fire” double burner.
+
: Perforation pattern “Line Fire” double burner.
Gas pipe “Rear burner”
“Rear burner”
Gas pipe “Front burner”
Motorknob
“Front burner”
8 Wire
connecting
cable
Pilot light
Thermocouple
Gas supply
connection
GAS
REGULATOR
BLOCK
Pilot light gas pipe
“black”
Thermocouple interruptor
“red”
Gas valve
“Rear burner”
2 Wire cable
“yellow”
“red”
Thermo-electrical
cable SW
Thermo-electrical
cable TC
Ignition(piezo)cable
Connection cable
(option) for
external operating
(i.a. Domotica
systems)
AUX
Receiver
(with battery compartment
for 4 AA-batteries)
Installation instructions
Button “RESET”
AC power
adapter
230 VAC
(option)
75
Bellfires
6
DIMENSIONS
6.1
HORIZON BELL SMALL TUNNEL 3
6.1.1
HORIZON BELL SMALL TUNNEL 3 - 2x Hidden Door
76
English
Installation instructions
Bellfires
6.1.2
English
HORIZON BELL SMALL TUNNEL 3 - 2x Floating Frame
Installation instructions
77
Bellfires
6.1.3
78
HORIZON BELL SMALL TUNNEL 3 -
English
1x Hidden Door
1x Floating Frame
Installation instructions
Bellfires
6.1.4
HORIZON BELL SMALL TUNNEL 3 -
Installation instructions
English
1x Hidden Door
1x Hidden Door plus 7 cm
79
Bellfires
6.1.5
80
HORIZON BELL SMALL TUNNEL 3 -
English
1x Hidden Door
1x Hidden Door plus 10 cm
Installation instructions
Bellfires
6.1.6
English
HORIZON BELL SMALL TUNNEL 3 -
1x Hidden Door
1x Hidden Door plus 10 cm Stone
* With the high adjustable feet (option), the appliance can be installed till 350 mm above the floor.
With this model the remote control receiver and the gas regulating block
are located in the fire and can be accessed via the metal cover, under the
stone. The gas fire does not have a separate operating unit !!
Installation instructions
81
Bellfires
6.2
English
HORIZON BELL SMALL TUNNEL 3
Fitted with the options: - Convection top plate
- High adjustable feet
6.2.1 HORIZON BELL SMALL TUNNEL 3 - 2x Hidden Door
* With the high adjustable feet (option), the appliance can be installed till 350 mm above the floor.
82
Installation instructions
Bellfires
6.2.2
English
HORIZON BELL SMALL TUNNEL 3 - 2x Floating Frame
* With the high adjustable feet (option), the appliance can be installed till 350 mm above the floor.
Installation instructions
83
Bellfires
6.2.3
HORIZON BELL SMALL TUNNEL 3
English
-
1x Hidden Door
1x Floating Frame
* With the high adjustable feet (option), the appliance can be installed till 350 mm above the floor.
84
Installation instructions
Bellfires
English
OPERATING UNIT
Installation instructions
85
Bellfires
7
English
TECHNICAL DETAILS/REGULATIONS
National installation regulations:
UK : • Gas safety installation and use regulations 1998 plus all relevant
safety and building regulations concerning fire installation
• Document J: Combustion appliances and fuel storage systems
Model
: HORIZON BELL SMALL TUNNEL 3 CF (Centre Fire)
Gas
: NATURAL GAS
: BUTANE / PROPANE
Country
: GB; Great Britain/IE; Ireland
: GB; Great Britain/IE; Ireland
Product identification no
Type of appliance under CE-norm
Category of appliance
: 0063CM3684
: C11 / C31 / C31S
: I2H natural gas G20
: 0063CM3684
: C11 / C31 / C31S
: I3B/P butane/propane G30/G31
Nominal heat input
(Gross calorific value)
: 10.5 kW
: Butane (G30) : 9.7 kW
Propane (G31) : 8.1 kW
Nominal heat output
Efficiency class
NOx-class
: 8.1 kW
: 1 (85%)
:5
: 6.2 - 7.5 kW
: 1 (85%)
:5
Gas rate (max.)
: 1.03 m3s/hr.
: Butane (G30) : 750 gr/hr.
Propane (G31) : 620 gr/hr.
Supply pressure
: 20.0 mbar
: Butane (G30) : 37.0 mbar
Propane (G31) : 37.0 mbar
Burner pressure (max.) Hot
: 13.6 mbar(*)
: 29.0 mbar(*)
Burner pressure (max.) Cold
: 12.9 mbar(**)
: 29.0 mbar(**)
Burner pressure (min.)
: 1.4 mbar(***)
: 1.8 mbar(***)
Primary air inlet burner Rear
: 1x Ø8.0 mm
: 1x Ø20.0+corner mm +
2x Ø5.0 mm
Primary air inlet burner Front
: 1x Ø8.0 mm
: 1x Ø20.0+corner mm +
2x Ø5.0 mm
Gas regulator block (remote control)
Main burner
Main burner injector Rear
Main burner injector Front
Pilot light burner
Pilot light burner injector
Gas connection
Concentric flue system connection
: Mertik GV 60
: Centre Fire 827x130 mm
: no 190 (= 1x Ø1.90 mm)
: no 190 (= 1x Ø1.90 mm)
: SIT 0.145.019
: no 36 (SIT 0.977.091)
: 3/8” G / Ø12 mm
: Ø100 mm - Ø150 mm or
Ø130 mm - Ø200 mm
: Mertik GV 60
: Centre Fire 827x130 mm
: no 110 (= 1x Ø1.10 mm)
: no 115 (= 1x Ø1.15 mm)
: SIT 0.145.019
: no 23 (SIT 0.977.150)
: 3/8” G / Ø12 mm
: Ø100 mm - Ø150 mm or
Ø130 mm - Ø200 mm
86
Installation instructions
Bellfires
English
Model
: HORIZON BELL SMALL TUNNEL 3 CF (Centre Fire)
Gas
: NATURAL GAS
: BUTANE / PROPANE
Country
: GB; Great Britain/IE; Ireland
: GB; Great Britain/IE; Ireland
Batteries remote control
- Receiver
- Hand-transmitter
: 4x 1.5V AA
: 1x 9V block
: 4x 1.5V AA
: 1x 9V block
Weight:
- Basis model
- Including all options
- Convection package
: 111 kg
: 120 kg
: 6 kg
: 111 kg
: 120 kg
: 6 kg
(*) : Both burners at maximum. Appliance is on temperature.
(**) : Both burners at maximum. Appliance is cold.
(***) : Both burners at minimum.
Flue gas exhaust and combustion air supply:
Roof-mounted outlet : Concentric flue system Ø100 mm - Ø150 mm. Rigid and/or flexible.
Horizontal wall outlet : Concentric flue system Ø130 mm - Ø200 mm. Rigid.
With wall outlet, depending on the flue configuration; Ø100 mm - Ø150 mm or
Ø130 mm - Ø200 mm.
Heat changing surface: Entire front of the appliance.
Installation instructions
87
Bellfires
English
Model
: HORIZON BELL SMALL TUNNEL 3 LF (Line Fire)
Gas
: NATURAL GAS
: BUTANE / PROPANE
Country
: GB; Great Britain/IE; Ireland
: GB; Great Britain/IE; Ireland
Product identification no
Type of appliance under CE-norm
Category of appliance
: 0063CM3684
: C11 / C31 / C31S
: I2H natural gas G20
: 0063CM3684
: C11 / C31 / C31S
: I3B/P butane/propane G30/G31
Nominal heat input
(Gross calorific value)
: 11.0 kW
: Butane (G30) : 10.9 kW
Propane (G31) : 9.3 kW
Nominal heat output
Efficiency class
NOx-class
: 8.5 kW
: 1 (85%)
:5
: 7.2 - 8.4 kW
: 1 (85%)
:5
Gas rate (max.)
: 1.06 m3s/hr.
: Butane (G30) : 850 gr/hr.
Propane (G31) : 700 gr/hr.
Supply pressure
: 20.0 mbar
: Butane (G30) : 37.0 mbar
Propane (G31) : 37.0 mbar
Burner pressure (max.) Hot
: 12.0 mbar(*)
: 29.0 mbar(*)
Burner pressure (max.) Cold
: 11.3 mbar(**)
: 29.0 mbar(**)
Burner pressure (min.)
: 1.9 mbar(***)
: 2.1 mbar(***)
Primary air inlet burner Rear
: 1x Ø7.0 mm
: 1x Ø20.0+corner mm +
2x Ø5.0 mm
Primary air inlet burner Front
: 1x Ø7.0 mm
: 1x Ø20.0+corner mm +
2x Ø5.0 mm
Gas regulator block (remote control)
Main burner
Main burner injector Rear
Main burner injector Front
Pilot light burner
Pilot light burner injector
Gas connection
Concentric flue system connection
: Mertik GV 60
: Line Fire 827x130 mm
: no 180 (= 1x Ø1.80 mm)
: no 220 (= 1x Ø2.20 mm)
: SIT 0.145.019
: no 36 (SIT 0.977.091)
: 3/8” G / Ø12 mm
: Ø100 mm - Ø150 mm or
Ø130 mm - Ø200 mm
: Mertik GV 60
: Line Fire 827x130 mm
: nr. 110 (= 1x Ø1.10 mm)
: nr. 130 (= 1x Ø1.30 mm)
: SIT 0.145.019
: no 23 (SIT 0.977.150)
: 3/8” G / Ø12 mm
: Ø100 mm - Ø150 mm or
Ø130 mm - Ø200 mm
88
Installation instructions
Bellfires
English
Model
: HORIZON BELL SMALL TUNNEL 3 LF (Line Fire)
Gas
: NATURAL GAS
: BUTANE / PROPANE
Country
: GB; Great Britain/IE; Ireland
: GB; Great Britain/IE; Ireland
Batteries remote control
- Receiver
- Hand-transmitter
: 4x 1.5V AA
: 1x 9V block
: 4x 1.5V AA
: 1x 9V block
Weight:
- Basis model
- Including all options
- Convection package
: 111 kg
: 120 kg
: 6 kg
: 111 kg
: 120 kg
: 6 kg
(*) : Both burners at maximum. Appliance is on temperature.
(**) : Both burners at maximum. Appliance is cold.
(***) : Both burners at minimum.
Flue gas exhaust and combustion air supply:
Roof-mounted outlet : Concentric flue system Ø100 mm - Ø150 mm. Rigid and/or flexible.
Horizontal wall outlet : Concentric flue system Ø130 mm - Ø200 mm. Rigid.
With wall outlet, depending on the flue configuration; Ø100 mm - Ø150 mm or
Ø130 mm - Ø200 mm.
Heat changing surface: Entire front of the appliance.
Installation instructions
89
Bellfires
8
English
REPLACEMENT PARTS LIST
When requesting service or ordering replacement parts, please quote the model type
and serial number. All parts listed in this manual may be ordered from a Bellfires dealer.
No
Article no
1
334987
2
3
4
5
6
334984
334988
334988
334990
334992
7
334986
8
9
10
11
12
334985
334994
334993
301928
334992
13
14
15
16
17
18
19
20
21
22
23
24
25
333597
302122
302084
302089
333607
333608
333610
333611
302086
333601
333602
333598
333599
26
27
28
333600
302068
302421
90
Description
Main burner “Centre Fire” 827 x 130 mm
Natural gas G20 / Butane/Propane G30/G31
G20:
1x Ø8.0 mm front + 1x Ø8.0 mm rear
G30/G31: 1x Ø20.0+corner mm + 2x Ø5.0 mm front and
1x Ø20.0+corner mm + 2x Ø5.0 mm rear
Burner mat L = 827 mm “Centre Fire”
Main burner injector Natural gas; Front: no 190 (1x Ø1.90 mm)
Main burner injector Natural gas; Rear: no 190 (1x Ø1.90 mm)
Main burner injector Butane/Propane; Front: no 115 (1x Ø1.15 mm)
Main burner injector Butane/Propane; Rear: no 110 (1x Ø1.10 mm)
Main burner “Line Fire” 827 x 130 mm
Natural gas G20 / Butane/Propane G30/G31
G20:
1x Ø7.0 mm front + 1x Ø7.0 mm rear
G30/G31: 1x Ø20.0+corner mm + 2x Ø5.0 mm front and
1x Ø20.0+corner mm + 2x Ø5.0 mm rear
Burner mat L = 827 mm “Line Fire”
Main burner injector Natural gas; Front: no 220 (1x Ø2.20 mm)
Main burner injector Natural gas; Rear: no 180 (1x Ø1.80 mm)
Main burner injector Butane/Propane; Front: no 130 (1x Ø1.30 mm)
Main burner injector Butane/Propane; Rear: no 110 (1x Ø1.10 mm)
Gas regulator block; GV 60 (M10 Thermocouple connection)
3/8” male x Ø12 Compression fitting
Nut Ø8 mm for burner supply GV 60 for “front burner”
Olive Ø8 mm for burner supply GV 60 for “front burner”
Gas valve “rear burner”
Adapter 3/8”bsp x 3/8”+ O-ring
Nut Ø8 mm for gas valve “rear burner”
Olive Ø8 mm for gas valve “rear burner”
Cut-off nipple Ø4 mm GV 60
Cable (sw): Receiver - Thermocouple interrupter, L = 500 mm
Cable (tc): Receiver - Thermocouple interrupter, L = 500 mm
Hand-held transmitter: Display screen: Temperature and two programmes
Cover battery compartment hand-held transmitter - with imprint:
Operating double burner
Receiver GV 60 - EU
8 Wire connecting cable Gas regulator block - Receiver, L = 500 mm
Piezo ignition cable, 2x 2.8 x 0.8 mm, L = 1500 mm
Installation instructions
Bellfires
English
No
Article no
Description
29
30
321926
333604
Thermocouple M10 - 1500 mm
Thermocouple interrupter M10
31
32
33
34
35
36
37
38
39
40
41
310908
310909
310910
310912
310907
302062
319842
332552
332553
322552
325750
42
325750
Pilot light set outer casing, Double flame
Packing pilot light set outer casing
Pilot light injector; Natural gas; no 36
Pilot light injector; Butane/Propane; no 23
Piezo electrode for pilot light, 2.8 x 0.5 mm
Nut piezo electrode
Nut thermocouple
Pilot light olive; Ø4 mm, steel
Pilot light nut; Ø4 mm, steel
Pilot light pipe; Ø4 mm, L = 1500 mm, Flexible, Stainless steel
Burner pipe; Ø8 mm, L = 1500 mm, Flexible, Stainless steel - 10 kW+,
“front burner”
Burner pipe; Ø8 mm, L = 1500 mm, Flexible, Stainless steel - 10 kW+,
“rear burner”
43
44
326055
326054
Nut; Ø8 mm, compression elbow main burner
Olive; Ø8 mm, compression elbow main burner
45
46
330712
330711
Glass Horizon Bell Small 3 (Tunnel) Hidden Door (990 x 399 x 4 mm)
Glass Horizon Bell Small 3 (Tunnel) Floating Frame (982 x 405 x 4 mm)
47
301669
Tube ceramic glue
48
49
50
51
301593
319664
311006
301617
Black fibre glass tape 15 x 3 mm, adhesive
Black fibre glass tape 30 x 2 mm, adhesive
Black fibre glass tape 20 x 2 mm, adhesive
Black fibre glass cord Ø10 mm
Installation instructions
91
Set
Art. no:
Horizon Bell Small Tunnel 3
C 325292
Marble pebbles Marble pebbles
set (white)
set (grey)
Log no
Chips of
wood set
Embers with Vermiculite no 4
Glow-effect black
Anthracite
filtered
1
2
3
4
5
6
7
8
3 pieces
Bag: 125 gr.
Bag: 50 gr.
Bag: 2,5 kg.
Bag: 2,5 kg.
331357
331358
331359
331360
331361
331362
331363
331364
xxxxxx
301863
332583
310937
325758
1x
2x
1x
1x
1x
1x
-
1x
2x
4x
1x
3x
3x
Bellfires
Log set
English
Installation instructions
Logs - Chips of wood - Embers - Vermiculite granules - Marble pebbles
92
Appliance
Bellfires
9
English
DISPOSING OF PACKAGING AND APPLIANCE
The appliance comes in recyclable packaging.
This can include:
• Cardboard
• Wood
• Plastic
• Paper
Such materials must be disposed of responsibly, in line with local regulations.
Batteries should be disposed of as chemical waste. Batteries must be disposed of
responsibly, in line with local regulations.
The authorities or fitter can provide you with information on responsible disposal of
obsolete appliances.
Installation instructions
93
Bellfires
94
English
Installation instructions
Your Bellfires dealer
01 - 151014 - 336827

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement