Installation Instructions 3475.301 3475.501

Installation Instructions 3475.301 3475.501
COLONY/COLONY SOFT
Bidet Faucet and Transfer
with Speed Connect™ Drain
Installation
Instructions
3475.301
Valve
3475.501
Congratulations on purchasing your American
Standard faucet with the Speed Connect drain, a
feature found only on American Standard faucets.
Certified to comply with ANSI A112.18.1
Speed Connect Drain*
M 9 6 8 7 9 6 R ev. 1. 2
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Roughing-in Dimensions
BIDET OUTLINE
IS SYMBOLIC
(C)
7/8 DIA.
DOUCHE ADJ. 1-1/4
SPRAY
TO 2-1/4
3-7/8
8 TO 12
DIVERTER AND
VACUUM BREAKER
ASSEMBLY
FINISHED
WALL
TRANSFER VALVE
(FOR FLUSHING
RIM OR SPRAY)
Recommended tools
Plumbers' Putty or
Caulking
Screwdriver
2-1/4
DIA.
(H)
1-3/16 DIA.
2-1/8
DIA.
4-1/4
1-1/4 MAX.
Phillips Screwdriver
Channel Locks
FOR GROUND JOINT
CONNECTION OR 1/2 "
O.D. SLIP (INLETS)
1-3/8
DIA.
REAR VIEW WITH
WALL REMOVED
FINISHED
FLOOR
5-1/2
Adjustable Wrench
Tubing Cutter
1-1/4 O.D. TAILPIECE
1
BIDET FAUCET INSTALLATION
CAUTION
Turn off hot and cold water
supplies before beginning.
11
6
Place RUBBER RING (10) into ADAPTER (4).
7
Install LOCKNUT (1) and RUBBER WASHER (2) onto VALVE BODIES (3, 3a). From
under side of mounting surface, install VALVE BODY (3, 3a) through valve mounting
holes. Threads of VALVE BODY (3, 3a) should extent at least 5/16 of a inch above
mounting surface top. Fig. A. Thread ADAPTER (4) onto VALVE BODIES (3, 3a)
until snug against internal stop. If necessary, adjust LOCKNUT (1).
Tighten LOCKNUTS (1) with WRENCH (5) (supplied)
to secure VALVE BODIES (3, 3a).
Remove MOUNTING NUT (6), WASHER (7) and
UPPER GASKET (8) from TRANSFER VALVE (9).
Insert TRANSFER VALVE (9) into the center forward
hole of BIDET.
5/16''
MIN.
SPRAY INSTALLATION
Assemble SPRAY BODY (1) to BIDET. Using putty, seal underside
of SPRAY BODY FLANGE (2) and secure with NUT (3).
Thread SPRAY HOSE (4) with SEAL WASHER (5) to SPRAY BODY (1).
Connect other end of HOSE (4) with SEAL WASHER (6) to side outlet
NIPPLE (7) of the TRANSFER VALVE (8).
Thread SPRAY CAP (9) onto SPRAY BODY (1).
1
BIDET
LEDGE
10
4
10
Fig. A.
MOUNTING
SURFACE
3a
3
2
1
2
1
Replace UPPER GASKET (8) and WASHER (7) . Position
the side threaded outlet rearward and secure MOUNTING
3, 3a
NUT (6). Thread ESCUTCHEON (11) onto TRANSFER
VALVE (9) until it seats against the BIDET LEDGE.
2
4
COLD
HOT
9
8
5
8
2
9
7
PUTTY
1
6
3
4
5
4
3
POP-UP DRAIN
Fig. A.
Fig. B.
Remove CLEAR PLASTIC COVER (1).
1
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
3
DRAIN
BODY
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY. Fig. B.
7
2
4
REMOVE FLANGE
Fig. A.
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain
body. Fig. A.
Fig. B.
1
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3). Fig. B.
5
6
INSTALL DRAIN FROM
BELOW FIXTURE
From under side of BIDET
install DRAIN BODY (1) up
through drain outlet.
Note: No plumber’s putty
or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the BIDET.
3
TIGHTEN LOCKNUT
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
4
3
DRAIN
OUTLET
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above BIDET and tighten
FLANGE (4) firmly.
7
4
2
FLANGE GASKET
1
1
2
Fig. A.
Fig. B.
1
3
Check DRAIN FLANGE in BIDET to ensure that WHITE
FOAM GASKET (1) is fully compressed and not visible.
Fig. A.
DRAIN
FLANGE
POP-UP ROD ASSEMBLY
Insert LIFT ROD GUIDE (1) and CABLE CONNECTOR (2)
through rear hole, making sure SEAL WASHER (3) is
properly seated. Fig. B.
5
WHITE FOAM
1 GASKET
From below slip slot in MOUNTING NUT (4) over CABLE (5).
Thread NUT (4) onto lift rod guide shank to secure ROD
GUIDE (1) to bidet. Hand tighten only. Fig. B.
NOT VISIBLE
SLOTTED
MOUNTING
NUT
4
ILLUSTRATION
SHOWN LESS
VALVES
2
M 9 6 8 7 9 6 R ev. 1. 2
2
8
ATTACH CABLE
CONNECTOR
Fig. A.
POP-UP KNOB (1) must be fully
down. Fig. A.
Fig. B.
Fig. C.
DOWN
1
Thread CABLE CONNECTOR (1)
clockwise onto DRAIN BODY
CONNECTION (2) and hand
tighten. Fig. B.
Your new POP-UP DRAIN
installation is now complete.
Fig. C.
2
1-1/4” O.D.
Note: Tailpeice on pop-up drain
is 1-1/4” O.D. Fig. C.
9
CHECK OPERATION OF POP-UP
5
4
Operate LIFT KNOB (1) to verify that STOPPER (2)
opens and closes.
3
1
Note: If STOPPER (2) does not open and close properly
then refer to the “troubleshooting section” of these
instructions.
1
2
INSTALL DIVERTER KNOB
2
Push DIVERTER KNOB (1) onto HANDLE ADAPTER (2).
Push on RING (3) and tighten with SCREW (4).
Press on KNOB CAP (5).
Note: Screwdriver gap is for disassembling and should
point downwards.
10
TEE AND HOSE CONNECTION
Insert SEAL (1) into ADAPTER (2) and tighten ADAPTER (2) to
bottom of TRANSFER VALVE (3).
Install SEAL (4) into coupling nut of TEE (5) and tighten
connection to ADAPTER (2).
3
Connect HOSE COUPLING NUTS (6) to Hot and Cold valve
bodies and securely tighten.
1
4
WATER SUPPLY CONNECTION
7
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT
INCLUDED AND MUST BE PURCHASED SEPARATELY.
6
7a
2
6
Front
5
COUPLING
NUT
3
3/8 O.D.
BULL-NOSE
RISERS
1/2" PIPE
Connect water supply to VALVE BODIES (7,7a) with
THREAD
1/2" IPS FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE
RISERS (3). Use adjustable wrench to tighten connections.
2
Do not over tighten. Be careful not to kink copper supply when
FLEXIBLE
bending. Use tubing cutter to cut to proper length.
SUPPLIES
COMPRESSION
NUT
FERRULE
Connect HOT water supply to inlet of left SHANK and COLD
water supply to right SHANK using sealant, appropriate
connectors, and COUPLING NUTS.
COLD
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
HOT
CONNECT TO
WASTE OUTLET
3/8 COMPRESSION
CONNECTION
M 9 6 8 7 9 6 R ev. 1. 2
3
INSTALL HANDLES (Lever)
INSTALL HANDLES (Acrylic)
Turn HANDLE STEM (1) to "OFF"
position.
Turn HANDLE STEM (1) to "OFF"
position.
Place the HANDLE ADAPTER (2)
on the HANDLE STEM (1).
Install the ADAPTER SCREW (3)
and tighten securely. Position
LEVER HANDLE (4) and place
on ADAPTER (2).
Install the HANDLE SCREW (5)
and tighten securely with hex
wrench supplied.
12
Place the ACRYLIC HANDLE (2)
on the HANDLE STEM (1).
5
4
3
Install the HANDLE SCREW (3)
and tighten securely.
3
4
H
11
Push in INDEX BUTTON (4).
2
2
1
1
TEST INSTALLED FITTING
5
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
1
3
Operate both HANDLES (1) to flush water
lines thoroughly.
Rotate TRANSFER VALVE (5) from rim wash to
spray several times to check operation.
13
1
4
CHECK DRAIN CONNECTIONS
SPRAY
Pull up POP-UP KNOB (3) and fill Bidet with water. Check
that DRAIN STOPPER (4) makes a good seal and retains
water in Bidet. If STOPPER (4) does not seal properly,
please refer to “Troubleshooting Guide” in these instructions.
2
Push POP-UP KNOB (3) down and check all drain
connections and "P" trap for leaks.
Tighten
if necessary.
2
14
EverClean™ Finish
Care Instructions
American Standard’s EverClean
finish will wipe clean with a soft,
dry cloth.
A soft cloth with clean water
may also be used, if desired.
No additional cleaning products
are required.
DO NOT USE: Soaps, acid,
polish, abrasives, harsh
cleaners, or a cloth with a
coarse surface.
15
SERVICE
To change direction of handle
rotation, proceed as follows:
Turn VALVE to OFF position.
Loosen HANDLE SCREW (1) .
Pull HANDLE (2) off ADAPTER (3). Loosen ADAPTER
SCREW (4) and pull off ADAPTER (3).
Turn ADAPTER (3) 90˚ in a way that flat in ADAPTER (3)
catches on the other FLAT on VALVE STEM (5).
Reinstall ADAPTER SCREW (4) and LEVER HANDLE (2).
Tighten HANDLE SCREW (1).
1
2
4
3
5
If spout drips, operate handles several
times from OFF to ON position. Do not
force - handles turn only 90˚.
M 9 6 8 7 9 6 R ev. 1. 2
4
Speed Connect™ Drain
Troubleshooting Guide
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
CABLE ADJUSTMENT PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
Fig. A.
Fig. B. Fig. C.
DOWN
CAM
1
1
RE-ATTACH
CAM CAP
DISCONNECT
STOPPER
2
STOPPER REMOVAL PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
Fig. D.
Fig. E.
REMOVE
CAM
Fig. F.
REMOVE
CAM CAP
M 9 6 8 7 9 6 R ev. 1. 2
5
STOPPER INSTALLATION PROCEDURE
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Fig. G.
LOGO
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
LOOP TOWARD
REAR OF BIDET
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
DRAIN
Locked Mode
(Vandal Proof)
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
Fig. H.
LOGO
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
180˚
LOOP TOWARD
FRONT OF BIDET
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
DRAIN
Unlocked Mode
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable.
Fig. J.
CAM
INSTALL CAM
Fig. K.
INSTALL
CAM CAP
M 9 6 8 7 9 6 R ev. 1. 2
6
COLONY/COLONY SOFT
BIDET FITTING
MODEL NUMBERS
918428-0070A
HANDLE SCREW
3475.301
3475.501
M962182-002OA
HANDLE
M961702-0020A
TRANSFER VALVE KIT
H
M950144-0070A
INDEX, BUTTON, HOT
M950143-0070A
INDEX, BUTTON, COLD
M962482-0020A
POP-UP ROD
M962481-0020A
LIFT ROD GUIDE
923348-0070A
HANDLE ADAPTER
M918504-0070A
SCREW
M907617-0020A
ESCUTCHEON
TRANSFER VALVE
M908413-0070A
ACRYLIC HANDLE
M916803-0020A
METAL LEVER HANDLE
M962456-0020A
STOPPER
ASSEMBLY
M952430-0070A
CABLE ASSEMBLY
M953131-0070A
TRANSFER VALVE
MOUNTING KIT
M919660-0020A
6” TAILPIECE
(NOT INCLUDED
WITH FAUCET)
M962457-007A
FLANGE
ASSEMBLY
M953130-0070A
TRANSFER VALVE
M918075-0070A
HANDLE SCREW
M922872-0070A
CAM SEAT INSERT
M952426-0020A
DRAIN ASSEMBLY
M961643-0020A
ESCUTCHEON KIT
M921323-0070A
ELBOW ADAPTER
M962430-0070A
CAM ASSEMBLY
M962458-0070A
DRAIN MOUNTING KIT
M918504-0070A
SCREW
M913207-0070A
TAILPIECE INSERT
M918021-0070A
ADAPTER
M962463-0020A
TAILPIECE & ESCUTCHEON
M904900-0070A
VALVE NUT
028704-0070A
TEE AND HOSE KIT
(INCLUDING SEALS)
A954120-0070A
VALVE
065800-0070A
ATTACHMENT NUT
072574-0070A
EXTENSION
066116-0020A
DRAIN STOPPER
M950145-0020A
POP-UP ROD
028645-0020A
BIDET SPRAY
070847-0070A
CLIP
066117-0020A
DRAIN FLANGE KIT
024220-0070A
SUPPLY NUT
066118-0070A
PIVOT ASSEMBLY
M961711-0070A
TAILPIECE INSERT
Appropriate finish code
CHROME
M961656-00020A
LIFT ROD GUIDE
002
030280-0040A
TAILPIECE WITH
ESCUTCHEON
POP-UP DRAIN AND LIFT ROD ASSEMBLY
BEFORE 05/06
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800-442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
028646-0070A
SPRAY HOSE
CONNECTION KIT
Product names listed herein are trademarks of American Standard Inc.
© AS America, Inc. 2008
M 9 6 8 7 9 6 R ev. 1. 2
7
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement