patlite1

patlite1
New Frontiers in Safety, Security and Comfort.
Explosion Protection &
Harsh Environment
http://www.patlite.com e-mail:[email protected]
8-8, Matsuyamachi, Chuo-ku, Osaka, Japan 542-0067
International Division, Sales and Marketing Department
TEL: +81-6-6763-8220 FAX: +81-6-6763-8221
E-mail:[email protected]
20130 S. Western Ave. Torrance, CA90501, U.S.A.
TEL: +1-310-328-3222 FAX: +1-310-328-2676
E-mail:[email protected]
No.2 Leng Kee Road, #05-01 Thye Hong Centre, Singapore 159086
TEL: +65-6226-1111 FAX: +65-6324-1411
E-mail:[email protected]
Room 512, Jufeng Business Building, No.697-3 Lingshi Road, Shanghai China 200072
TEL: +86-21-6630-8969 FAX: +86-21-6630-8938
E-mail:[email protected]
Am Soeldnermoos 8, D-85399 Hallbergmoos, Germany
TEL.+49-0-811 9981 9770-0 FAX.+49-0-811 9981 9770-9
E-mail : [email protected]
202 Seokwang Bldg. 1361-9 Seocho-dong, Seocho-gu, Seoul, 137-863
TEL.+82-2-523-6636 FAX.+82-2-523-6637
LOT 321 Batamindo Industrial Park, Jalan Beringin Mukakuning, Batam 29433 Indonesia
TEL: +62-770-61-1123 FAX: +62-770-61-2444
Sanda Plant
Headquarters
To ensure correct use of these products, read the Instruction Manual prior to use.
Failure to follow all safeguards can result in fire, electric shock, or other accidents.
Specifications are subject to change without notice.
ISO14001
ISO 9001
Certified
Headquarters
Sanda Plant
Techno Center
PT. PATLITE INDONESIA
For the benefit of mankind
and the earth, PATLITE is
committed to developing
environmentally friendly
products.
0120B 1108F(F)/JF(NP)B
PATLITE (U.S.A.)
PATLITE Europe GmbH
PATLITE (SINGAPORE)
PATLITE KOREA
Explosion-Proof
Explosion-Safe
Intrinsically-Safe
Robust Heavy Duty
World-wide Sales, Marketing and After-sales Support Network.
Factory
Sales Subsidiary
PATLITE Europe GmbH
Munich, Germany
PATLITE Europe GmbH
PATLITE KOREA CO.,LTD.
Seoul, Korea
Sanda Plant
PATLITE KOREA CO.,LTD.
Sanda Plant
Sanda, Japan
PATLITE (U.S.A.) Corporation
Los Angeles
PATLITE (CHINA) Corporation
PATLITE (CHINA)
Corporation
Shanghai
PATLITE (SINGAPORE) PTE LTD
PATLITE (U.S.A.) Corporation
PT. PATLITE INDONESIA
PT. PATLITE INDONESIA
PATLITE (SINGAPORE) PTE LTD
“New Frontiers in Safety, Security and Comfort” is
PATLITE`s mission.
PATLITE offers state-of-the-art equipment for process and
industrial automation for over 60 years. Our Innovative and
robust design, backed by a powerful commitment and years
of knowledge, has made PATLITE the world’ s best known
manufacturer of the visual and audible signaling products.
We are also dedicated to the development of explosive and
harsh-environment products to demonstrate our strong
commitment to serving the industry with unique and
innovative solutions.
In order to identify the diversified needs of our customers, and
respond quickly and satisfactorily to those needs, we have
implemented the POP (Point of Production) System together
with a lean-manufacturing cell-based assembly system
(combination, single, and flexible assembly). These new systems allow us to handle any order rapidly from
single items to customized item orders.
Wide-range of Innovative and World-class Quality Products.
We’ ve also reduced development time and production cost by
having our own in-house machinery to produce, design and
manufacture metal moldings and plastic materials with the use
of injection machinery. From designing to production, from raw material to the
finished product, we also manage our quality control
throughout the entire process. This is how we maintain our
world class quality reputation in the visual, audible signaling
and networking information products.
■ From designing to production, quality control is managed throughout the process.
Design with 3-D CAD
1
Manufacturing of metal
molding parts
Electrical discharge machine
Machining Center
Injection molding machines
2
■ How Explosion Occurs
Mixture of oxygen and explosive substance develop
explosive gases. When the concentration of the substance in
air is within the lower and upper explosive limits, the mixture
can be ignited.
To prevent an explosion, one of three prerequisites must be
eliminated. To make equipment an ignition-free to install in
explosive environment is one of the solutions.
PATLITE offers Explosion Proof, Explosion-Safe,
Intrinsically-Safe visual and audible signaling products as
well as LED illumination work lights in order to increase
safety in the work environment.
■ Various Applications for Explosion-Proof, Explosion-Safe and Harsh Environments.
Prerequisites for an explosion
Branch
Explosive
Material
Oxygen
Power Generation Companies
Lump Coal Dust
Woodworking Industry
Saw Dust
Fine Wood Chips
Metal-work Operations
Explosive Metal Dust
Spark-ignitable Metal Dust
Food/Beverage Industry
Ignitable Grain Dust
Explosive Sugar Dust
Refinery Industry
Hydorocarbons close to their flash-points
Oil Processing Plants
Waste Disposal Companies
Waste-water Treatment Gasses
Landfills/Civil Engineering
Flammable Landfill Gases
Uncontrolled Gas Emissions
Flammable Gas from poor ventillation
sources
Pharmaceutical Industry
Alcohol Solvents
Materials explosive when mixed
Gas Suppliers
Natural Gas Leakage
Natural Gas Emissions
Paint-spraying Operations
Overspray in Spray-paint Bays
Solvent Vapor Emissions
Recycling Operations
Unemptied flammable gas/liquid containers
Biodegradable Material Emitting
Explosive Gasses
Chemical Industry
Flammable Gases
Flammable Liquids
Flammable Solids
Agriculture
Bio-gas Production Plants
Bio-gas Located on Farms
Explosion
Source of
Ignition
■ An explosive environment is categorized in three segments, Zone 0, Zone 1
and Zone 2, depending on the hazardous level of gases and vapors.
Zone 0
An area where an explosive atmosphere consisting of a
mixture of air containing flammable substances in the form of
gas, liquid, or vapor is continuously present and/or frequent.
Zone 1
An area where an explosive atmosphere consisting of a
mixture of air containing flammable substances in the form of
gas, liquid or vapor is likely to occur under normal conditions
on occasion.
3
Explosion Hazard
Zone 2
An area where an explosive atmosphere consisting of a
mixture of air containing flammable substances in the form of
gas, liquid, or vapor is not likely to occur under normal
conditions. However, if it occurs, it will only be for short
periods of time.
4
■ Relationship of IEC, CENELEC, NEC 505 and NEC 500
Classification of Hazardous Areas
IEC: International Electrotechnical Commission
CENELEC: European Committee for Electrotechnical Standardization
NEC: National Electrical Code
■ Gases/Vapors
A tank filled with flammable liquid: There is a potential risk
of an explosion which may occur inside the tank.
Therefore, the inside of the tank is categorized as Zone 0.
Vapor may escape on occasion through the vent on the top
of the tank, therefore the area around the vent is
categorized as Zone 1.
The vapor may also run down the outside of the tank,
developing another explosive environment, so the area
around the tank is categorized as Zone 2.
IEC/CENELEC
Zone 0
Zone 1
USA:NEC 505
Zone 0
Zone 1
Zone 2
Zone 2
Division 1
USA:NEC 500
Explosive Material
Division 2
Class
Group
I
A, B, C, D
Gas, Vapor or Liquid
Dust
II
E, F, G
Fibers
III
Gas, Vapor or Liquid
Explosive Material
Class
Group
I
A, B, C, D
Dust
II
E, F, G
Fibers
III
Gases/Vapors
Equipment
Group
Standards
Explosive
Atmosphere:
Gas or Dust
Category
<International Standards>
IEC
<E.U. Standards>
CENELEC ATEX Directive 94/9/EC
<U.S. Standards>
NEC 505
Ⅱ
2
G
Class 1, Zone 1
Zone 0, 1, 2
ATE X
E C 6 0 0 7 9 -1 0
IE C
IE C 6 0 0 7 9 -1 0
US
NEC505
NEC500
Constant Exposure
Occasional Exposure
Rare and Temporary
Zone 0 (Category 1)
Zone 1 (Category 2)
Zone 2 (Category 3)
Zone 0
Zone 1
Zone 2
Zone 0 (class Ⅰ )
Zone 1 (class Ⅰ )
Zone 2 (class Ⅰ )
Division 1 (Class Ⅰ)
Ex
de
IIC
T4
Ex
de
IIC
T4
AEx
de
IIC
T4
Types of
Protection
Gas Group
Temperature
Class (max.
surface
temperature)
■ IP Protection Rate: Index of Ingress Protection
IEC60529
IP
Division 2 (Class Ⅰ)
■ Dust
At a mill with a feed hopper and filter: A product, which
causes dust particles mixed with sufficient air to cause an
inflammable mixture, is loaded into a hopper.
Inside the feed hopper and filter, it is categorized as Zone 20.
While the product is being loaded, the mixture of dust and air
Group
causes a potentially explosive compound in the area where
the product is loaded into the hopper, so the area outside the
hopper is categorized as Zone 21.
Around the hopper where a potential inflammable atmosphere
exists temporarily is categorized as Zone 22.
5
6
IP69K
The entrance of dust is not closed completely.
But dust may not go into the device in such manner
as the optimal operation of the device and the safety
are impaired.
No intrusion of dust into the device
5
No detrimental effect occurs when a jet-stream is applied to the
test sample from any direction. (TEST: 12.5 liter/min. of water is
sprayed with a jet nozzle, having an internal diameter of 6.3mm,
and a distance from the test sample of 2.5m - 3m away)
6
No detrimental effect occurs when water is sprayed onto the test
sample by a jet-stream from any direction. (TEST: 100 liter/min. of
water is sprayed with a jet nozzle, having an internal diameter of
12.5mm, with a distance of 2.5m - 4m away from the test sample)
7
Water must not enter into the device. No detrimental effect
occurs when the device is submerged in a depth of 1 meter of
water for 30 minutes.
8
Water must not enter into the device. No detrimental effect
occurs when the device is continuously submerged. The test
conditions are to be mutually agreed upon by the manufacturer
and user.
IP69K is the German DIN 40050 PART9 standard. It is defined as a protection regulation for high temperature and high-pressurized water.
Water is heated up to 80 ゚C and sprayed at a water pressure in the range from 80 to 100 bars at 14 to 16 liters per minute at the test
object. The test object is at a distance of 100 to150 mm from the nozzle and sprayed in all directions at 0, 30, 60, and 90 degrees, then
sprayed at a horizontal angle while it is being rotated, all done for a period of 30 seconds without being affected by water penetration.
90°
10-15cm
60°
30°
0°
Constant Exposure
Occasional Exposure
Rare and Temporary
E C 6 1 2 4 1 -1 0
Zone 20 (Category 1)
Zone 21 (Category 2)
Zone 22 (Category 3)
IE C
IE C 6 1 2 4 1 -1 0
Zone 20
Zone 21
Zone 22
US
NEC505
IP69K Test Procedure
Division 2 (Class Ⅱ)
Note: Model CLA LED light bars comply with IP69K.
See page 16 for more details.
ATE X
NEC500
5
Division 1 (Class Ⅱ)
6
Zone 1
Zone 2
Explosion-proof Maintenance Free LED Signal Lights
The EDLM and EDWM series LED signal lights are visual
warning and status indicating lights for use in hazardous
locations that requires compliance with the ATEX Directive
94/9/EC (CENELEC standard) or NEC Article 505 certification.
A wide range of visual and audible signaling products, as well
as super bright LED light bars, designed for use in hazardous
locations that require the ATEX Directive 94/9/EC (CENELEC
Standard). These unique and innovative models meet the
The EDLM and EDWM series offers wide range of voltages
and versatile mounting options to meet various applications.
The following chart explains the comparison between the
ATEX Directive 94/9/EC (CENELEC standard) and NEC
Article 505 certification. To find the most suitable models,
refer to page 9 and 10.
Protection Type "tD"
In flame-proof enclosures,
an explosion is contained.
Dust-protected and
flame-proof enclosure.
EWH24E/EXN
CLF2024/EXN
EDLM
AR-070 Series
AR-078 Series
EDWM
■ Standard Markings
Markings for North America (NEC Standards)
Marking for ATEX Directive (CENELEC Standard)
Ⅱ 2 G
CE 0000
CE Marking
Notified Body Number
ATEX Directive Marking
NEC505 (Zone System)
Class I, Zone1, A Ex d ⅡC T6
Type of Explosive Environment
Category
Equipment Group
American National Standard
Explosion Protection
Temperature Code
Gas Group
NEC500 (Division System)
Ex tD A21 IP66 T80℃
Class I, Division1, Groups A,B,C,D, T6
Temperature Class
Dust Protection Codes (only type of Ex tD)
Dust Area Classification (only type of Ex tD)
Explosion Protection
Protection Method
Flammable Gas or Vapor
■ Explosion-proof Protection
Ex d
Flameproof
Increased Safety
Intrinsic Safety
(2 faults)
Intrinsic Safety
(1 fault)
Purged/Pressurized
Encapsulation
1, 2
IEC
IECEx
EN60079-1
IEC60079-1
AEx d
1, 2
Ex e
1, 2
EN60079-7
IEC60079-7
AEx e
1, 2
Ex ia
0, 1, 2
EN60079-11
IEC60079-11
AEx ia
0, 1, 2
Ex ib
1, 2
EN60079-11
IEC60079-11
AEx ib
1, 2
Ex p
1, 2
EN60079-2
IEC60079-2
AEx p
1, 2
Ex m
1, 2
EN60079-18
IEC60079-18
AEx e
1, 2
Ex n
2
EN60079-15
IEC60079-15
AEx n
2
NEC500
US
Division
US
FM3615
ANSI/ISA
1, 2
UL1203
60079-1
ANSI/ISA
60079-7
ANSI/ISA
FM3610
1, 2
60079-11
UL913
ANSI/ISA
60079-11
ANSI/ISA
FM3620
1, 2
60079-2
NFPA496
ANSI/ISA
60079-18
FM3611
2
UL1604
ANSI/ISA
60079-15
■ ATEX Directive (CENELEC)
Equipment
Group
Explosive
Environment
Flammable
Substances
M1- Very High Level
Constant
Exposure
Methane
M2- High Level
1- Very High Level
Ⅱ -other
areas
7
Ocassional
Exposure
Coal Dust
Constant
Exposure
Gases
2- High Level
Ocassional
Exposure
3- Normal Level
Rare and
Temporary
Temperature Code
Class Ⅰ
Zone 0
An area where the mixture of explosive gas is
continuously present or present for long periods.
Zone 1
Class Ⅰ
Zone 1
An area where the mixture of explosive gas
can be present during normal operation.
Zone 2
Class Ⅰ
Zone 2
An area where the mixture of explosive gas is
not normally present, but if it occurs, it will only
be for brief periods of time.
Vapors
Dust
Vapors
Mists
Dust
T1
(450℃)
Hazardous
Areas
Zone 20
An area where the mixture of incendiary dust is
continuously present or present for long periods.
Zone 21
An area where the mixture of incendiary dust
can be present during normal operation.
Zone 22
An area where the mixture of incendiary dust is
not normally present, but if it occurs, it will only
be for brief periods of time.
Zone 2 (Gases)
Zone 22 (Dust)
T3
(200℃)
Ⅰ
Methane
ⅡA
Acetone
ethane
Propane
Ethyl Alcohol
Gasoline
n-butane
Diesel fuel
Lighting
gas
Ethylene
Zone 0 (Gases)
Zone 20 (Dust)
Zone 1 (Gases)
Zone 21 (Dust)
T2
(300℃)
ⅡB
ⅡC
Cyclohexane
Acrylonitrile
Ethylene
oxide
Hydrogen
Acetylene
Aircraft fuel
Ethylene
glyco
Hydrogen
sulphide
T4
(135℃)
T5
(100℃)
Model Selection
AR-070 Series
AR-078 Series
Page
11
12
Model Selection
LKEHFV/EXN
LKEHFE/EXN
Page
Model Selection
PVW04JF/EXN
EWH24E/EXN
Page
14
15
Model Selection
CLT3024S-CD
CLF2024/EXN
CLA series
Page
16
16
16
PVW04JF/EXN
LED Signal Towers
CENELEC Standard
EN60079-0, EN60079-15
EN60079-0 , EN60079-15
CE
CE
Explosion Safety
II DG Ex nA II T4, Ex tD A22 IP65 T85℃
II DG Ex nA II T4, Ex tD A22 IP65 T85℃
MP3 Field Progmmable Annunciator integrated with LED tower
CENELEC Standard
EN60079-0, EN60079-15
EN60079-0 , EN60079-15
13
13
CENELEC Standard
EN60079-0, EN60079-15
EN60079-0 , EN60079-15
Dust
Zone22
Zone22
Hazardous Area
CE
CE
Gas
Zone2
Zone2
CE
CE
Explosion Safety
II DG Ex nA II T4, Ex tD A22 IP65 T85℃
II DG Ex nA II T4, Ex tD A22 IP65 T85℃
Gas
Zone2
Zone2
CE
CE
CE
Explosion Safety
II DG Ex nA II T4, Ex tD A22 T135℃
II DG Ex nA II T4, Ex tD A22 T135℃
II DG Ex nL IIC T4, Ex iD A22 T135℃
Gas
Zone2
Zone2
Zone2
Super Bright LED Light Bars
CENELEC Standard
EN60079-0, EN60079-15
EN60079-0 , EN60079-15
EN60079-15
Hazardous Area
Gas
Zone2
Zone2
Explosion Safety
II DG Ex nA II T4, Ex tD A22 IP65 T85℃
II DG Ex nA II T4, Ex tD A22 IP65 T85℃
Voice Annunciator, Melodies & Chimes Horns
T6
(85℃)
II
2
G
Dust
Zone22
Zone22
Hazardous Area
Dust
Zone22
Zone22
Hazardous Area
Dust
Zone22
Zone22
Zone22
Ex d IIC T6
Type of Ex Atmosphere
G ....... Gas
D ....... Dust
Equipment-Category
M1 ..... very high safety level (Mines)
M2 ..... high safety level (Mines)
1 ........ very high safety level
2 ........ high safety level
3 ........ normal safety level
Equipment-Group
I ......... For mining installations
II ........ For industrial installations
Specific mark for explosion protection
Registration number of Notified
Body certified the
QA system (if applicable).
Quality mark for compliance with the
EU directives, as a product passport to the
European Market (not for components).
Acetaldehyde
Ethyl-ether
Carbon
Bisulfide
CLT3024/EXN
* These products are manufactured by PATLITE, converted to Ex Certification by Artidor, and sold by Patlite.
0123
Hazardous Area Classification
Zone 0
Gases
LKEHFE/EXN
LKEHFV/EXN
■ Markings
■ ATEX/IEC Classification for Gases & Temperature Coding
CategoryProtection Level
Ⅰ -mines
CENELEC NEC505
IEC
North America Class Ⅰ
NEC505
Protection
Zone
CENELEC
ATEX
Non-incendiaries
Type-n
Gas Group
Area Classification
■ Zone Classification
Europe (ATEX Directive / (CENELEC) International (IEC)
Protection Method Protection
Zone
Code
Temperature Code
Gas Group
Protection Method
Flammable Gas or Vapor
Area Classification
Ex d ⅡC T6
Explosion-Protected
Type of Protection
criteria for Zone 2 (gas) and Zone 22 (dust) atmospheres.
The CLA series LED light bars meets the criteria for
intrinsically safe applications.
CLA Series
■ Protection Method (ATEX/IEC)
Flame-proof Enclosure Type "d"
Explosion-Safe Visual/Audible Signaling Products &
LED Light Bars
Coal
disulphide
Temperature Class
(Maximum Surface Temperature)
T1 ..... 450℃
T2 ..... 300℃
T3 ..... 200℃
T4 ..... 135℃
T5 ..... 100℃
T6 ..... 85℃
Gas Group
I ........ Methane(fire damp)
II ....... All gasses
IIA ..... Propane & equivalent
IIB ..... Ethylene & equivalent
IIC ..... Hydrogen & Acetylene
III ...... Fiber Flying
Protection degree against ignition
d ....... Flameproof Enclosure
e ....... Increased Safety
ia/ib/ic .......... Intrinsic Safe
ma/mb/mc.... Moulded Encapsulation
nA ..... Non-sparking
nC ..... Separated
nL ..... Energy Limited
nR ..... Restricted Breathing
o ....... Oil Immersion
px/py/pz ....... Pressurising
q ....... Powder Filling
Explosion Safe
8
Zone 1
EDLM SERIES & EDWM SERIES EXPLOSION-PROOF
Testing Authority PTB,
■ Descriptions
126
0
Class Ⅰ , Zone 1
AEx d ⅡC T6
-25℃∼+50℃ (No Frezing)
45%∼85%RH (Keep from dew or condensation)
80∼110kpa
Flashing (60±12 flashes per minute) / Continuous Lighting
IP66
9.8m/s 2
Outdoor & Indoor Upright & Sideways
Outdoor & Indoor Upright
Red: 350mcd, Amber: 580mcd
Red/Green/White: 1000mcd
Green: 1300mcd
Amber: 700mcd, Blue: 300mcd
4.3kg
4.7kg
Upper & Lower case: Aluminum Alloy
(Housing Finish: Melamine-baked Finish)
Glass case: Borosilicate Glass
Fitting Bracket: Stainless,Steel (sus 316)
(31)
347
92
Gray
Yellow
L
R
L
Y
L
G
L
B
L
W
F
C
V
1
V
2
9
<External Application>
External Protection Fuse
1A
Power
Source
Continuous Lighting
External Contacts
Flashing
External Contacts
Power Wire
Power Wire
Flashing COM
LED White
Flashing
External Contacts
LED Blue
LED Green
LED Amber
LED Red
■ EDWM-5M2FE/FA
■ EDLM-312FE/FA
EDLM-323FE/FA
<Main Body Casing >
<Main Body Casing>
<External Application>
L L L C F V V
R Y G C C 1 2
Earth
Ground
Power Wire
Power Wire
Flashing COM
Continuous COM
LED Green
LED Amber
LED Red
External Protection Fuse
1A
Power
Source
L L L L L C F V V
R Y G B W C C 1 2
Continuous Lighting
External Contacts
Flashing
External Contacts
Black
EDWM-502FA
EDWM-5M2FA
AC/DC 24V
AC 90∼250V
Red: 22.6mA, Amber: 26.6mA, Green: 17.5mA
Blue/White: 38.9mA
Power
Source
Gray
EDLM-323FA
AC 230V
External Protection Fuse
1A
V
2
Brown
EDLM-312FA
AC 120V
Red/Amber: 52.5mA
Green: 20.0mA
V
1
Yellow
EDLM-302FA
AC/DC 24V
F
C
Power Wire
Power Wire
Flashing COM
LED Green
LED Amber
LED Red
Green / Yellow
■ NEC Article 505
L
G
Continuous Lighting
External Contacts
Upper & Lower Case: Aluminum Alloy
(Housing Finish: Melamine-baked Finish)
Glass Case: Borosilicate Glass
Fitting Bracket: Stainless Steel (SUS 316)
Cable Gland: Brass
Material
L
Y
Brown
L
R
<External Application>
White
Mass (Main Body)
Red
-20℃∼+50℃ (no ice)
45%∼85%RH (Keep from dew condensation)
80∼110kpa
Flashing (60±12 flashes per minute) / Continuous Light
IP66
9.8m/s 2
Outdoor & Indoor
Upright & Sideways
Outdoor & Indoor
Upright
Red/Green/White: 1000mcd
Red: 350mcd, Amber: 580mcd
Amber: 700mcd, Blue: 300mcd
Green: 1300mcd
4.7kg
4.3kg
Luminosity
<Main Body Casing >
<Main Body Casing>
Red
Orange
Green
Yellow
Brown
Gray
Black
OperatingTemperature
Operating Humidity
Ambient Pressure
Lighting Pattern
Protection Rating
Vibration Resistance
Mounting
■ EDWM-502FE/FA
■ EDLM-302FE/FA
Ⅱ 2 G Ex d ⅡC T6 (Zo n e 1 , 2 )
Ⅱ 2 D Ex t D A2 1 I P6 6 T8 0 ℃ (Zo n e 2 1 , 2 2 )
Explosion Protection
Ratings
9
14
φ
EDWM-502FE
EDWM-5M2FE
AC/DC 24V
AC 90∼250V
Red: 22.6mA, Amber: 26.6mA, Green: 17.5mA
Blue/White: 38.9mA
White
EDLM-323FE
AC 230V
EDWM (5 color LED)
Blue
EDLM-312FE
AC 120V
Red/Amber: 52.5mA
Green: 20.0mA
Wiring Diagram
EDLM (3 color LED)
Green
■ CENELEC (ATEX Directive)
EDLM-302FE
AC/DC 24V
Wiring Diagram
Division 2
Blue
Division 1
Orange
ANSI/NFPA 70
Green
NEC Article 500
Orange
Zone 2
Red
Zone 1
Red
Zone 0
Material
(Unit: mm)
Green / Yellow
EDLM, EDWM
Gray
ANSI/NFPA 71
Yellow
NEC Article 505
15
56
Set Screw
Brown
Present
Abnormally
Mass (Main Body)
50
Terminal Block
Green
Present
Intermittently
Luminosity
9
38
Cover
Orange
Present
Continuously
OperatingTemperature
Operating Humidity
Ambient Pressure
Lighting Pattern
Protection Rating
Vibration Resistance
Mounting
11
218
PATLITE
Models
Explosion Protection
Ratings
φ
φ
(Horizonal-mount)
Plug
NEC standard is National Electrical Code.
Standard
Model
Voltage Rating
Signal line Current
(Per LED Module)
56
4
Zone 2
(140)
50
Zone 1
Classification
Model
Voltage Rating
Signal line Current
(Per LED Module)
(86)
9
Earth Terminal
M4 Screw
56
Zone 0
56
O-ring
56
218
9
NEC Standards for the USA
EDLM, EDWM
■ Flush-mount Bracket
15
283
(415)
335
3/4 NPT
11
IEC 60079-10
EN 60079-10
Present
Abnormally
Gland Port 1
3/4 NPT
Gland Port 2
*ATEX Model ... Standardized Part
*NEC Model ...... Non-Standardized Part
φ
ATEX, IEC/EU
Directive 94/9/EC
Standard
Present
Intermittently
Lower Enclosure
φ
Classification
Present
Continuously
(24)
3/4 NPT
Glass Enclosure
φ 120
ATEX directive is CENELEC standard.
PATLITE
Models
■ Cable Gland*
LED Modules
■ EDLM & EDWM meet the specifications shown in the shaded areas below
CENELEC Standards for Europe
■ installation
(Wall-mount)
(48)
Vertical Mount
Upper Enclosure
(48)
EDWM
Fitting Bracket
152
φ 4.4
5
EDLM
90
12
Housing: Aluminum alloy
Glass: Borosilicate glass
Terminals: Easy wire connection to the Signal Tower by opening the bottom
Mounting: Upright, Wall Mount, Vertical-mount, and Horizontal Mount
LED color: Different color configurations are possible to custom-design
Voltage: 24VAC/DC, 120VAC, 230VAC, 90-250VAC are available.
Wire core size: 0.5mm2~0.8mm2, AWG20~AWG18
Horizontal Mount
38
347
■ Features
12
Dimensions (EDLM, EDWM)
The EDLM (colored 3 tiered LED) and EDWM (colored 5 tiered LED) are innovative
LED maintenance free Signal Towers. The robust design with pressure and
flame-proof housing is ideal for use in potentially flammable and hazardous explosive
atmospheres such as chemical, petrochemical, combustible dust, production of
mineral/natural gas, and even in the manufacturing of polysilicon for the photovoltaic,
semi-conductor industries, as well as the food and beverage industries.
Wall Mount
NEC Article 505 Testing Authority
Earth
Ground
Power Wire
Power Wire
Flashing COM
Continuous COM
LED White
LED Blue
LED Green
LED Amber
LED Red
<External Application>
External Protection Fuse
1A
Power
Source
Continuous Lighting
External Contacts
Flashing
External Contacts
10
Zone 2
Zone 2
AR-070 SERIES
AR-078 SERIES
EXPLOSION-SAFE
II 3 GD; Ex nA II T4; Ex tD A22 IP65 T85°C 94/9/EC (ATEX) and 2004/108/EC (EMC) EN60079-0, EN60079-15, EN61241-0, EN61241-1
EXPLOSION-SAFE
II 3 GD; Ex nA II T4; Ex tD A22 IP65 T85°C 94/9/EC (ATEX) and 2004/108/EC (EMC) EN60079-0, EN60079-15, EN61241-0, EN61241-1
Explosion-safe Signal Light Ø40mm
Explosion-safe Signal Light Ø60mm
■ Description
■ Description
Explosion-safe Signal Light featuring an LED light that is versatile and energy-efficient. The
vertical and horizontal cut lenses in combination with a double-reflection system enhances the
LED light diffusion to create a unique, full and brilliant light. The lenses and main body are made
of strong synthetic materials with characteristics to withstand harsh environments. The Signal
Light can be ordered in any combination from 1 to 5 LED units with any color combination. In
addition to its “continuous lighting” condition, the Signal Light can also be ordered with flashing /
non-flashing functions, as well as with two super-loud alarm sounds with an 90dB (at 1m) output.
Explosion-safe Signal Light featuring an LED light that is versatile and energy-efficient. The
vertical and horizontal cut lenses in combination with a double-reflection system enhances the
LED light diffusion to create a unique, full and brilliant light. The lenses and main body are made
of strong synthetic materials with characteristics to withstand harsh environments. The Signal
Light can be ordered in any combination from 1 to 5 LED units with any color combination. In
addition to its “continuous lighting” condition, the Signal Light can also be ordered with flashing /
non-flashing functions, as well as with two super-loud alarm sounds with an 85dB (at 1m) output.
■ Features
■ Features
AR-070 series
■ Specifications
■ Dimensions
II 3 GD; Ex nA II T4; Ex tD A22 IP65 T85°C
EN 60079-0, EN 60079-15, EN 61241-0, EN 61241-1
Certification:
Ambient Temperature:
Ingress Protection:
Material:
Lighting Source:
Acoustical Source:
Rated Voltage:
Assembly position:
Activation Time:
SIGNAL LIGHT
EC-Declaration of conformity
-30 °C to +60 °C
IP65 to EN 60529
ABS towerbody, polyester glassfibre reinforced base
Multiple LEDs with double reflection system
Buzzer 85 dB (1m) with two different tones
24 V AC/DC
As desired
100%
Module Colors Available:
60
Red, Amber, Green, Blue, Clear/white
Cable:
-30 °C to +60 °C
IP65 to EN 60529
ABS towerbody, polyester glassfibre reinforced base
Multiple LEDs with double reflection system
Buzzer 90 dB (1m) with two different tones
24 V AC/DC
As desired
100%
Module Colors Available:
Red, Amber, Green, Blue, Clear/white
Cable:
Factory sealed cable, Ø 8 mm, length 3 meter
CURRENT RATINGS
BUZZER
Current
70
approx. 250 mA
CONNECTION DIAGRAMS
8
Inrush
40
Line Current
approx. 40 mA
Signal
Red, Amber
approx. 30 mA
60
23
Signal
EC-Declaration of conformity
M4
LED
Line Current
Green, Blue, Clear
approx. 25 mA
II 3 GD; Ex nA II T4; Ex tD A22 IP65 T85°C
EN 60079-0, EN 60079-15, EN 61241-0, EN 61241-1
Certification:
14
AR-078 series
■ Specifications
Ambient Temperature:
Ingress Protection:
Material:
Lighting Source:
Acoustical Source:
Rated Voltage:
Assembly position:
Activation Time:
Factory sealed cable, Ø 8 mm, length 3 meter
CURRENT RATINGS
Signal
Red, Amber
approx. 30 mA
From 1 to 5 tiers
3/4” NPT bracket for pole mount is available as an option.
Available with “flashing/non flashing” and
two audible buzzer alarm sounds
Ingress protection of IP65
Wall mount or direct mount
Explosion-safety:
CE conformities:
12
Explosion-safety:
CE conformities:
41
SIGNAL LIGHT
Explosion-safe for gas and dust
Suitable for Zone 2 and Zone 22
CE compliance in accordance to ATEX
Full and brilliant lumination
LED double reflection lighting system
Different lens colors available
124
■ Dimensions
From 1 to 5 tiers
Available with “flashing/non flashing” and two
audible buzzer alarm sounds
Ingress protection of IP65
Wall mount or direct mount
LED
BUZZER
Line Current
Green, Blue, Clear
approx. 25 mA
Signal
Line Current
Inrush
approx. 40 mA
31
Explosion-safe for gas and dust
Suitable for Zone 2 and Zone 22
CE compliance in accordance to ATEX
Full and brilliant lumination
LED double reflection lighting system
Different lens colors available
Current
approx. 250 mA
CONNECTION DIAGRAMS
42
R=20
12
4.5
0°
15
20
3/4” NPTbracket (Option)
60
120°
4.5
EXPLOSION-SAFE SIGNAL LIGHT
Continuous lighting (only)
1
Continuous/Flashing lighting
and two Audible alarms
2
Code
No. of Stacks
24V AC/DC
1
1-5
EXPLOSION-SAFE SIGNAL LIGHT
Code
1
2
3
4
5
Colors*
Red
Amber
Green
Blue
Clear/White
Units: mm
Units: mm
Type number AR-070 0
11
Code
R
Y
G
B
C
1 /
- RYGBC
*Colors are arranged from top to bottom
How to order
25
Voltage
7
Code
25
How to order
35
Code
Continuous lighting (only)
1
Continuous/Flashing lighting
and two Audible alarms
2
Type number AR-078 0
Voltage
Code
No. of Stacks
24V AC/DC
1
1-5
1 /
- RYGBC
Code
1
2
3
4
5
Colors*
Red
Amber
Green
Blue
Clear/White
Code
R
Y
G
B
C
*Colors are arranged from top to bottom
12
Zone 2
Zone 2
LKEHFE/EXN, LKEHFV/EXN
PVW04JF/EXN
EXPLOSION-SAFE
II 3 GD; Ex nA II T4; Ex tD A22 IP65 T85°C 94/9/EC (ATEX) and 2004/108/EC (EMC) EN60079-15, EN60079-0, EN61241-1, EN61241-0
105dB(A)
MP3 Field Programmable Announciator, Melody Horn
Explosion-safe for gas and dust
Suitable for Zone 2 and Zone 22
CE compliance in accordance to ATEX
Super bright LED colors correspond to different voice, sounds,
chimes and melodies.
Voice alert messages of up to 63 seconds (64kbit/s) with 5 channels
can be played back.
32 combinations of sounds, chimes and melodies are pre-recorded.
8 sounds can be played back by a bit input, and 32 sounds by binary input.
Volume is adjustable from 0 to 105dB at 1 meter.
Field programmable with MP3 by SD card for the model LKEHFV/EXN.
Well visible with the super bright 100mm diameter LED from far distance.
Robust design to withstand against 2G vibration.
The body is made of Acrylonitrite-Ethlene-Styrene for weather resistant.
Easy to control by only one common wire for both LED units and
audible signals.
NPN is standard. PNP open colletor type is also available on order.
Protection rating of IP65
105dB horn
PVW04JF/EXN
LKEHFV/EXN, LKEHFE/EXN
■ Dimensions
32 sounds are pre-recorded in one unit. 4 sound types are available.
8 sounds can be played back by a bit input, and 32 sounds by binary input.
Annie Laurie
Stutter
Synthesized Melody
Galactic Motor
London Bridge
Bell
Chime
Ringing Phone
Mary`s Lamb
Yelp
Call Sign
Two Tone
Camptown Races
Rapid Hi Lo
Train Ride
Alarm Clock
Amaryllis
Melody Chime
Galloping Hi Lo
Ringing Hi Lo
Symphony #40
Synthesized Piano
Alien Chatter
Fur Elise
Ave Maria
Synthesized Bell
Falling Crystals
Minuet
Grandfather's Clock
77
2-ø10
LKEHFE-F/EXN
3
14.2W
LKEHFE-W/EXN
3
14.2W
LKEHFV-F/EXN
Supports
3
14.2W
LKEHFV-W/EXN
Supports
3
14.2W
・LED units can be stacked to 1, 2, and 4 on order.
・SD card for the model LKEHFV-F/EXN and
LKEHFV-W/EXN sold separately.
110
142
Power
38
58
From wire exit 400
R7 (4x)
60
200
151
Flush mount bracket
for LKEHFE-F/EXN
& LKEHFV-F/EXN
Wall mount bracket
for LKEHFE-W/EXN
& LKEHFV-W/EXN
100
20
White
Voice: CH1~CH4·STOP
Black
1
Skyblue
2
Yellow
3
Pink
(
Is
500mA
+
STOP
Red
Source Voltage
Rated Voltage
12V
24V
COM Brown
DC
24V
BUSY OUT Orange
GND
Blue
Shielded wire
AUX OUT Green
3- ø9
Open Circuit: Vs=20V
Closed Circuit: Is=5mA
)
COM Brown
4 Light green
–
Fuse Capacity
1A
0.5A
An input of 100ms or more is required
to activate the message.
External Amplifier
25 25
125
142
LED stack
100
R10 (2x)
(mm)
142
0°
16.2
12
MP3
0
ø7
5
6
Model
Front
1
166
Inverted Revelle
Fuse
Power supply
25
Stutter + Bell
60
3-ø
152
142
°
20
186
143
120
230
Beep
Mounting Dimension
■ Wiring Diagram
105
Height
1 Light: 265.2
2 Lights: 325.3
3 Lights: 385.4
4 Lights: 445.5
※Height
Ultra bright
LED
■ Sound Selection Charts
Shaft
Explosion-safe for gas and dust
Suitable for Zone 2 and Zone 22
CE compliance in accordance to ATEX
4 pre-recordable messages on EPROM
Maximum 63 seconds for recording time.
Adjustable audible sound volume up to 105dB at 1 meter
ADPCM 64kbit/s clear sound quality from an LSI digital voice synthesizer.
Indoor Installation: upright, inverted, and sideways.
Outdoor: upright installation only.
Provided with an anti-corrosive stainless steel mounting bracket.
12/24VDC & 12/24VAC
Protection rating of IP65
Insert SD card
into the slot.
100
ø100
105dB (at 1m)
Voice Annunciator ADPCM 64kbit/s
122
■ Dimensions
EXPLOSION-SAFE
II 3 GD; Ex nA II T4; Ex tD A22 IP65 T85°C 94/9/EC (ATEX) and 2004/108/EC (EMC) EN60079-15, EN60079-0, EN61241-1, EN61241-0
Channel Priority
(mm)
STOP (Red) >CH4 (Light green) >CH3 (Pink) >CH2 (Yellow) >CH1 (Skyblue)
Note: The greater number has priority when any of the channels are activated simultaneously.
■ Specifications
Model
Rated
Voltage
PVW04JF
/EXN
12/24V
AC/DC
Power
Outer Contact
Operating
Voltage Range Consumption
Volume
Capacity Temperature Range
8~28V AC
9~35V DC
12W
Max.
105dB
at 1m
More than
10mA
-10°C~+55°C
Humidity
85% or less.
Auxiliary
Input
Channel
AUX
Output
BUSY
Output
Non-voltage
Contact
4/1bit
4
-10dBv
600
Max. load
24V
DC 500mA
Max Message Protection Mass
Time
63 sec.
IP65
1.3kg
■ Specifications
Model
Rated
Voltage
Voltage Range
LKEHFE-F/EXN
LKEHFE-W/EXN
13
MP3, Melody
Operating
Temperature
Type-E
24VDC
24VDC +/-10%
Type-E
LKEHFV-F/EXN
MPEG1-Audio layer III,
64kbit/s
LKEHFV-W/EXN
MPEG1-Audio layer III,
64kbit/s
Recordable
Duration
Sound Pressure
(at 1m)
Prerecorded
Messages
Mass
8ch bit input,
Flush mount 32ch binary input 2.8Kg
Prerecorded
-10C to +50C,
Humidity 85% or less
Mounting
Brackets
105dB
Wall mount
8ch bit input,
3.2Kg
32ch binary input
63 sec.
5ch bit input,
Flush mount 31ch binary input 2.8Kg
63 sec.
Wall mount
5ch bit input,
3.2Kg
31ch binary input
14
Zone 2
Zone 2
EWH24E/EXN
CLT3024S/EXN
EXPLOSION-SAFE
II 3 GD; Ex nA II T4; Ex tD A22 IP65 T85°C 94/9/EC CENELEC: EN60079-15, EN60079-0, EN61241-1, EN61241-0
EXPLOSION-SAFE
II 3 GD; Ex nA II T4; Ex tD A22 T135°C 94/9/EC CENELEC: EN60079-15, EN60079-0, EN61241-1, EN61241-0
105dB (at 1m) Melodies & Chimes Horn
Fuse
Red
6
Orange
7
Green
8
Blue
Approx. 400mm from wire exit
2 wire cord
25 25
Signal wires
Fuse Capacity
Model
Rated Voltage
Fuse
1A
EWH24E/
12-24V
(Slow-blow)
EXN
Sound selection made by dipswitch
125
Nominal sectional area : Cord type
0.75mm2 : VCT
Test Switch
8 (Blue) > 7 (Green) > 6 (Orange) > 5 (Red) > 4 (Lightgreen) > 3 (Pink) > 2 (Yellow) > 1 (Skyblue)
The greater number has priority when any of the channels are activated simultaneously.
CLA SERIES
■ Sound Selection Charts
Beep
Stutter + Bell
Inverted Revelle
Annie Laurie
Stutter
Synthesized Melody
Galactic Motor
London Bridge
Bell
Chime
Ringing Phone
Mary`s Lamb
Yelp
Call Sign
Two Tone
Camptown Races
Rapid Hi Lo
Train Ride
Alarm Clock
Amaryllis
Melody Chime
Galloping Hi Lo
Ringing Hi Lo
Symphony #40
Synthesized Piano
Alien Chatter
Fur Elise
Ave Maria
Synthesized Bell
Falling Crystals
Minuet
Grandfather's Clock
Explosion-safe for gas and dust
Suitable for Zone 2 and Zone 22
CE compliance in accordance
to ATEX
15
12/24V
AC/DC
42.5
φ15
Approx. 420
Approx. 150
11
φ1
5
5
120
4*
M
2-
Name plate
* When mounting with supplied nuts : φ4.5
Max.
105dB
at 1m
No more than 5A
-20°C~+60°C
Humidity
85% or less.
Channel
8ch/1bit
EWH: Non-voltage Contact
or
32ch/binary
IP65
■ Specifications
Mass
1.2kg
S24
(Unit: mm)
Models
CLA1S24CD/EXN
CLA1S24CN/EXN
CLA2S24CD/EXN
CLA2S24CN/EXN
CLA3S24CD/EXN
CLA3S24CN/EXN
Luminous
Color
Daylight
Natural White
Daylight
Natural White
Daylight
Natural White
Length
100mm
200mm
300mm
1
2
3
25
(Unit: mm)
Rated
Voltage
DC 24V
(Polarized)
Operating
Voltage Range
DC24V±10%
CLA3S24CD/EXN
■ Options
/ EXN
Length
30
Auxiliary Input
Protection
Rating
IP66, IP67 and IP69K rated
-40°C ∼ +60°C
Polycarbonate
Mounting brackets available
CLA
3-φ4.2(Beveled)
8W
220
208
230
100mm, 200mm and 300mm long
100mm: 140 lx, 200mm: 270 lx,
300mm: 400 lx
24VDC (polarized)
CLA1S:124, CLA2S:224, CLA3S:324
Operating
Power
Voltage Range Consumption
Volume Outer Contact Capacity Temperature Range
8~28V AC
9~35V DC
■ Dimensions
INTRINSICALLY-SAFE
■Dimensions
■ Specifications
EWH24E/
EXN
CLF2024C/EXN
II 3 GD; Ex nL IIC T4, Ex iD A22 T135℃ 94/9/EC CENELEC: EN60079-15, EN61241-11, EN61241-0
Pre-recorded on model EWH24E/EXN
Model
Model
CLF2024C/EXN
LED Color
C
Rated Voltage
24V DC (No polarity)
Operating Voltage Range
Rated voltage ±10%
Power Consumption
5W
Light Source
High intensity LED×8
Luminous Intensity at Optical Center (lx at 50cm)
1,700
Main Body
Housing: Aluminum Cover: Polycarbonate
Operating Temperature Range
-30°C ~ +60°C (No condensation 90% RH or less)
Indoor, Forward Direction
Installation
Protection Rating
IP67
Vibration Resistance
19.6m/s2
Mass
205g±10g
-30°C ∼ +60°C
Polycarbonate lens
Aluminum housing
Channel priority
The test switch can be used to check the operation or adjust sound volume
(Located under the cover).
Rated
Voltage
220mm long
1,700 lx
LED color: white 6800K
IP67 rated
■ Specifications
Nominal sectional area : Cord type
Power supply wire : 0.75mm2 : VCTF
Signal wire : 0.3mm2 : VCTF
White
25
80
11 wire cord
Black
3-φ9
Explosion-safe for gas and dust
Suitable for Zone 2 and Zone 22
CE compliance in accordance
to ATEX
5.5
Light green
5
φ4.1
Pink
4
50
Yellow
3
Fuse
EXPLOSION-SAFE
35
Skyblue
2
Signal wires for
External Contact
channel selection
Open circuit 20V
Closed circuit 5mA
58
(Unit: mm)
(8)
38
340
27
30
1
105
Power supply
wire
φ4.5
5
400 from wire exit
Brown
COM
166
122
100
22
(15.5)
II 3 GD; Ex nA II T4; Ex tD A22 T135°C 94/9/EC CENELEC: EN60079-15, EN60079-0, EN61241-1, EN61241-0
Black
186
143
120
230
CLF2024C/EXN
White
350
(10.5)
Cover
DIP switch, volume and test switch
are located under the cover.
CLT3024S/EXN
■ Dimensions
Model
CLT3024S/EXN
LED Color
Day light Color
Rated Voltage
24V DC
Operating Voltage Range
Rated Voltage ± 10%
Current Consumption
416mA ± 40mA
Light Source
High intensity LED × 16 elements
Luminous Intensity at
500
Optical Center (lx at 50cm)
Housing: Aluminum, Cover: Tempered glass
Main Body
-30℃~+60℃ (No condensation 90%RH or less)
Operating Temperature Range
Any Direction (for indoor use only)
Mounting Direction
IP66G/IP67G JIS C 0920: 2003/Aqueous oil resistant (Company Standards)
Protection Rating
19.6m/s2
Vibration Resistance
700g
Mass
■ Wiring Diagram
(Unit: mm)
IP67F rated
-30°C ∼ +60°C
Tempered glass lens
Aluminum housing
■ Specifications
EWH24E/EXN
■ Dimensions
350mm long
500 lx
24VDC, 416mA
LED color: white 6750 K
50
Explosion-safe for gas and dust
Suitable for Zone 2 and Zone 22
CE compliance in accordance
to ATEX
Explosion-safe for gas and dust
Suitable for Zone 2 and Zone 22
CE compliance in accordance to ATEX
32 combinations of melodies, chimes and sounds are pre-recorded.
Adjustable audible sound volume up to 105dB at 1 meter
Indoor Installation: upright, inverted, and sideways.
Outdoor: upright installation only.
Provided with the anti-corrosive stainless steel mounting bracket.
NPN is standard for the EWH type. PNP open collector is available on order.
CE compliant : 24VAC/DC only
IP65
LED color
CD
CN
100mm
200mm
300mm
Daylight 6800K
Natural white 4800K
Rear Attachment
(Magnetic Mount)
Model SZ-310ARM
Side Attachment
(Screw Mount)
Model SZ-310AS
Side Attachment
Model SZ-310ASB
*Stainless steel brackets are also available.
Rated Current Center Radiation
Consumption
(lx/50cm)
104mA
140
208mA
270
240mA
400
Main Body
Material
Operating
Temperature Range
ー40℃ to +60℃
Body:
(RH 90% or less
Polycarbonate No Condensation)
Mounting
Direction
Protection
Rating
Vibration
Resistance
Mass
Any Direction
(Indoor Use)
IP66/67/69K
19.6m/s2
130g
80g
180g
16
RES-A
Heavy Duty Revolving Warning Light for Harsh Environment
RLR
Robust Heavy Duty 11.2G LED Super Bright Beacons for Harsh Environment
Robust Heavy Duty Revolving Warning Light
162mm diameter
11.2G Anti-Vibration
IP66 Protection
Robust Heavy-duty Design
Dual LED with Twin Reflector
Maintenance-free with Brushless Motor
Strong Polycarbonate Housing
CE Compliant (12/24VDC)
φ224mm diameter.
Integral Rotating Parabolic Reflector: For enhanced visibility from a distance.
Installation: Indoors—upright, inverted, sideways; Outdoors—upright only.
Main Body: Aluminum alloy die-cast with silver color baked finish.
Dome: Acrylic resin covered with clear hard-glass, and metal guard.
Available Colors: Red, Amber, Green and Blue.
Approved by: TIIS (Technology Institution of Industrial Safety).
IP66
The metal cable gland is an optional part. Needs to order separately.
■ Dimensions
■ RES-A Type
227
296
Model
(80)
Rated Voltage
Current
RES-12A
12V DC
0.9A
RES-24A
24V DC
0.5A
0.3A
RES-48A
48V DC
RES-100A
100~110V AC
RES-120A
115~120V AC
RES-220A
200~220V AC
RES-240A
230~240V AC
Bulb···G18 BA15S
Rotations per Minute
170
150
Bulb
12V10W
9
24V10W
10
48V10W
11
6.5kg
0.1A
170
12V5W
Long Life
No. Mass
12
0.05A
: Special Order
The RLR has many advantages
compared to a rotating beacon
with incandescent bulb and
standard motor. The LEDs last
approximately 20 times to 40 times
longer than an incandescent bulb. The combination of
the brushless motor and bearing mechanism allows the
RLR to operate from 8,000 hrs to 10,000 hrs, compared
to 5,000 hrs for other rotating beacons.
Structure of conventional motor
5
Power
supply
Magnet
Shaft
Brush
Structure of Brushless motor
■ Dimensions
φ162
φ141
Shaft
Coil
Magnet
(mm)
330
Mounting Dimensions
Blank : φ140
P : φ120
■ Specification
90~250V AC
90~250V AC
2G (19.6m/s2)
Passenger Car
-30˚C~+70˚C
2
-10˚C~+50˚C
45m/s (4.5G)
-R (Red)
-Y (Amber) 1.0kg
-G (Green)
-B (Blue)
1.06kg
4.5G (44.1m/s2)
Construction Machinery
Mounting
Hole
3 –φ9
RLR / Bottom
40
Name Plate
7G (68.6m/s2)
Emergency Vehicle
Mounting
Hole
3 –φ9
0
0°
RLR-M2
2
110m/s (11G)
0
Wire Entry Hole
φ2
12
20~30V DC
φ2
RLR-P
20
9.5~15V DC
48V DC
Mass
3-M8
RLR-04・M1=φ6
RLR-M2=φ9
φ1
12/24V DC
RLR-04
Dome
0°
RLR-M1
Operating
Vibration
Resistance Temperature Range
12
Operating
Voltage Range
+80
0
Wire Entry Hole
40
Rated Voltage
RLR
φ1
TIIS is a non-governmental, non-profit and
self-sustaining organization founded in Japan in 1965
and recognized by the Minister of Health, Labor and
Welfare as a juridical incorporation, to help reduce
industrial accidents and contribute towards the benefits
of industrial sectors in Japan through its various
technological activities.
Model
26
G : Green
B : Blue
0°
04 : 48V DC
M1 : 12/24V DC
M2 : 90V AC~250V AC
Color
R : Red
Y : Amber
(15)
Rated Voltage
0°
130
RLR-04-P-R
65
193
■ Model Code
12
Brush
4- ø9
17
※Except RLR-M2
High
Protection
Commutator
Mounting Hole
130
High
Visibility
Magnet
Coil
Mounting Dimension
Coil
Electric circuit
Power
supply
Vibration
Resistance
12
□130
□150
LED + Brushless Motor + Bearing Mechanism
RLR-P / Bottom
40
Name Plate
mm
11G (107.8m/s2)
Dump Truck
18
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project