1314-200 Data Sheet
001 4162
PRODUCTION RELEASE
1314-200 (UNIDIRECTIONAL) & 1315-200
(BIDIRECTIONAL) 12 VOLT, 200 AMP
BATTERY SEPARATORS
.10
.030
2.5
.76
INTERPRET GEOMETRIC DIMENSIONS AND
TOLERANCING PER ASME Y14.5-1994
DRAWINGS IN THIS DOCUMENT ARE NOT TO SCALE
PROPRIETARY
THIS DRAWING IS THE PROPERTY OF SURE POWER INC. and shall not be
copied, reproduced, lent, or disposed of, nor used for any purpose other than
that for which it is specifically provided without the written permission of
SURE POWER INC.
DRAWN
P.J.
MODEL NO: 1314-200 & 1315-200 12V
200A BATTERY SEPARATORS
SPECIFICATION OUTLINE
6/25/04
PRJCT ENGR
ENGR MNGR
SALES/MRKTG
13XX-200-12V
A
NONE
SPEC 13XX-200-12V
1
F04-019-005
001
6
-SEE SHEET # 1-
OVERVIEW
The 1314-200 (unidirectional) and 1315-200 (bidirectional) are 200A battery separator modules with an integrated
relay for 12V systems. The units monitor both the main and auxiliary battery banks. If the main battery (for the
1314-200) or either battery bank (for the 1315-200) is above the connect threshold, the relay connects the two
banks together. If the main battery (for the 1314-200) or either batteries (for the 1315-200) are below the
disconnect threshold the unit will open the relay. The connect threshold is set to a nominal voltage of 13.2V,
which would only be reached when the charging system is operating. This will cause the relay to close and the
charging system can charge both banks of batteries. The disconnect voltage is set to a nominal 12.8V, which is
near the full charge resting voltage of the batteries. This will cause the relay to be opened shortly after the engine
is stopped, attempting to preserve 100% of the starting battery capacity for engine cranking. When the engine is
started, the start signal causes the controller to check if the auxiliary battery is within about 0.85V of the main
battery; if so, the relay contact is closed. Thus providing the starter system with maximum battery voltage
available.
UNIT CONNECTIONS:
The unit has five connections:
1.
Main Battery connection
This is the high current connection to the main battery bank. This connection is made directly to the relay.
Product labeling refers to this as the MAIN BAT connection. The unit is powered from the main battery
connection or the auxiliary battery connection, drawing power from whichever has the higher voltage.
2.
Auxiliary Battery connection
This is the high current connection to the auxiliary battery bank. Product labeling refers to this as the AUX
BAT connection. The unit is powered from the main battery connection or the auxiliary battery connection,
drawing power from whichever has the higher voltage.
Note: For the 1315-200 model, the battery connections can be reversed.
3.
Ground
This is the unit ground connection.
4.
Start signal input
This is the input for engine start signal override. When power is applied to this input, the relay will close if the
Aux. Battery is no less than 0.85 Volts below the Main battery.
5.
Start lamp output
This is the start lamp drive output. The start lamp is powered when the start signal input has caused the relay
to close. This output can source up to 250mA.
MODEL NO: 1314-200 & 1315-200 12V
200A BATTERY SEPARATORS
SPECIFICATION OUTLINE
13XX-200-12V
A
NONE
SPEC 13XX-200-12V
2
F04-019-005
001
6
-SEE SHEET # 1-
ENVIRONMENTAL SPECIFICATIONS:
Control module is encapsulated in epoxy. Relay is water resistant.
Characteristic
Parameter
Unit
Notes
Relay Temperature Range
-40 TO +60
°C
Operating condition
Control Temperature Range
-40 TO +85
°C
Operating condition
Storage Temperature Range
-55 to +105
°C
Humidity
0 to 95
%RH
Vibration
See Notes
Shock
See Notes
Thermal Shock
See Notes
+/-3% @ 50-amp load. IAW SAE J1455 (Rev.
Aug94), Section 4.2.3, Figure 4a.
IAW SAE J1455 (Rev. Aug94), Represents design
intent
IAW SAE J1455 (Rev. Aug94), Section 4.10.3.1 &
4.10.3.2.2, Represents design intent
@ 50-amp load. IAW SAE J1455 (Rev. Aug94)
Section 4.1.3.2, Figure 2c. Represents design intent
ELECTRICAL SPECIFICATIONS:
MAXIMUM RATINGS:
Maximum ratings establish the maximum electrical rating to which the unit may be subjected without
damage.
Characteristic
Symbol
Parameter
Unit
VINMAX
16
V
Damage to relay MAY occur if repeatedly operated
above 16V
Standoff Voltage
VSO
40
V
Applies to AUX BATT, MAIN BATT, and START
SIGNAL terminals only.
Time at Standoff
tSO
Continuous
Continuous Relay
current
IR,MAXC
200
A
Inrush Relay current
IR,MAXI
600
A
START LAMP drive
current
ILAMP
250
mA
Electrical Isolation
VISO
500
V AC
Input Voltage
Notes
Not current limited. Drawing more than 250mA may
damage unit.
All terminals together with respect to ground.
MODEL NO: 1314-200 & 1315-200 12V
200A BATTERY SEPARATORS
SPECIFICATION OUTLINE
13XX-200-12V
A
NONE
SPEC 13XX-200-12V
3
F04-019-005
001
6
-SEE SHEET # 1-
Note: All terminals protected against reverse polarity except reversing one of the battery bank polarities. (Relay is
not current limited. Connecting battery banks of opposite polarity will damage relay).
ELECTRICAL CHARACTERISTICS:
Unless otherwise stated, conditions apply to full operational temperature range and full voltage range (9V
to 16V)
Characteristic
Symbol
MIN
Normal Input Voltage
VIN
9
Minimum Input Voltage
VINMIN
Contact life
TYP
MAX
Unit
Notes
16
V
Voltage range unit is guaranteed to
function within specification.
8.5
V
Minimum coil pull-in voltage is 8.5V @
25°C.
50,000
Cycles
Connect Voltage:
VCON
13.2
V
@ 25°C, See note.
Disconnect Voltage:
VDCON
12.8
V
@ 25°C, See note.
Quiescent Current
IQUES
10
Relay drive current
IRELAY
1.5
A
START LAMP output
voltage
VLAMP
Battery
voltage –
1.4V
V
Battery voltage being the higher of the
two battery stack voltages.
START SIGNAL
threshold voltage
VSST
1.5
V
Voltage where START SIGNAL input
switches state.
s
When the battery voltage rises above the
connect voltage and the relay closes, this
is the minimum amount of time it will stay
closed, regardless of the battery
voltages.
s
When the battery voltage falls below the
disconnect voltage and the relay opens,
this is the minimum amount of time it will
stay open, regardless of the battery
voltages.
Connect debounce
Disconnect debounce
tCD
tDD
4.4
7.2
13
mA
Relay off, Start Signal input open or
grounded.
Note: Typical voltage settings have ± 2% tolerance.
MODEL NO: 1314-200 & 1315-200 12V
200A BATTERY SEPARATORS
SPECIFICATION OUTLINE
13XX-200-12V
A
NONE
SPEC 13XX-200-12V
4
F04-019-005
001
6
-SEE SHEET # 1-
ELECTROMAGNETIC COMPATIBILITY:
Transient Immunity Tests
Load Dump
Inductive Switching Kick
Mutual Inductance
Electrostatic Discharge Immunity
Level1
14 + 86e(-t/0.4)
14 + 400e(-t/0.001)
14 - 600e(-t/0.001)
14 ± 300e(-t/0.000015)
Level1
ESD – Packaging and Handling
±8 kV direct
±15 kV air
ESD – In vehicle
±8 kV direct
±15 kV air
Radiated Immunity Test
Level1
Absorber Lined Chamber
100MHz to 4GHz
75-100V/m
Stripline Test Method
10kHz to 100MHz
100V/m
Emissions Limit Test
Level2
Radiated Emissions
Narrowband
30MHz to 1GHz
Radiated Emissions
Broadband
30MHz to 1GHz
Notes
IAW with SAE J1455 (Rev. Aug94), Section
4.11.2.2, Table 4a. Pulse applied to MAIN BATT
and AUX BATT terminals
IAW with SAE J1455 (Rev. Aug94), Section
4.11.2.2, Table 4a. Pulse applied to all terminals
except GND and LAMP.
IAW with SAE J1455 (Rev. Aug94), Section
4.11.2.2, Table 4a. Pulse applied to all terminals
except GND.
Notes
IAW with SAE J1455 (Rev. Aug94), Section
4.11.2.2.5.1 / SAE J551/15 utilizing a
150pF/150Ω discharge network.
IAW with SAE J1113, Part 13 (Rev. Feb95)
utilizing a 330pF/2kΩ network.
Notes
Ref. SAE J1113, Part 21 (Rev. Oct94). Amplitude
Modulation: 80% at 1kHz. Antenna and DUT at
one meter.
Ref. SAE J1113, Part 23 (Rev. Sep95). Amplitude
Modulation: 80% at 1kHz.
Notes
Per standard
ISO 13766:1999, section 6.5
EN 13309:2000, section 4.6
Per standard
ISO 13766:1999, section 6.4
EN 13309:2000, section 4.5
1
Immunity levels represent design intent.
Sufficient to apply CE marking .
2
MODEL NO: 1314-200 & 1315-200 12V
200A BATTERY SEPARATORS
SPECIFICATION OUTLINE
13XX-200-12V
A
NONE
SPEC 13XX-200-12V
5
F04-019-005
001
6
-SEE SHEET # 1-
MECHANICAL SPECIFICATIONS:
Weight: Approximately 1.9 LBS. (0.86Kg)
Terminal Torque Specifications
Characteristic
Battery terminals (5/16-24)
Coil terminals (10-32)
Maximum
50
Units
inch-lbs
20
inch-lbs
Note: Quick connect tabs are ¼” and spacing is compatible with Delphi P/N 12040949.
UNIT DIMENSIONS
AUX BAT
MAIN BAT
LAMP
START
SIGNAL
(4.06 [103.1])
2X 10-32
STUD
GND
(1.63 [41.4])
1.37 [34.7]
(3.28 [83.2])
(2.00 [50.8])
3X MALE QUICK CONNECT TAB
2X 5/16-24 STUD
4.02 [102.1]
(3.91 [99.3])
2X .28 [7.1]
3.30 [83.8]
(1.85 [47.0])
2X FULL R
MODEL NO: 1314-200 & 1315-200 12V
200A BATTERY SEPARATORS
SPECIFICATION OUTLINE
13XX-200-12V
A
NONE
SPEC 13XX-200-12V
6
F04-019-005
001
6