LiftMaster LA500 1PKGDC, DC, DCS Gate Opener Installation Manual
Below you will find brief information for Gate Opener LA500 LA5001PKGDC, Gate Opener LA500 LA500DC. This manual details the installation procedure for the LA500 series of gate openers, which are designed for use in vehicular swing gate applications. The manual includes detailed instructions for installing the operator arm, control box, and entrapment protection devices. It also covers topics such as wiring, programming, troubleshooting, and maintenance. This manual is intended for use by qualified professionals and should not be used as a substitute for proper training and experience.
TABLE OF CONTENTS
SAFETY 1
SAFETY SYMBOL AND SIGNAL WORD REVIEW .....................................1
USAGE CLASS ..........................................................................................2
UL325 ENTRAPMENT PROTECTION REQUIREMENTS .............................2
SAFETY INSTALLATION INFORMATION ...................................................3
GATE CONSTRUCTION INFORMATION .....................................................4
INTRODUCTION 5
CARTON INVENTORY ...............................................................................5
SPECIFICATIONS ......................................................................................6
SITE PREPARATION .................................................................................7
CHECK YOUR GATE ..................................................................................7
OVERVIEW OF TYPICAL INSTALLATION ..................................................8
INSTALLATION 9
IMPORTANT SAFETY INFORMATION .......................................................9
INSTALLATION TIPS .................................................................................9
POSITION THE BRACKETS .....................................................................10
ATTACH THE BRACKETS ........................................................................11
INSTALL THE CONTROL BOX .................................................................12
EARTH GROUND ROD ............................................................................14
WIRE THE OPERATOR ARM TO THE CONTROL BOARD ........................14
DUAL GATES ONLY ................................................................................15
INSTALL ENTRAPMENT PROTECTION ...................................................18
POWER WIRING .....................................................................................20
FINISH INSTALL .....................................................................................22
ADJUSTMENT 22
LIMIT AND FORCE ADJUSTMENT ..........................................................22
OBSTRUCTION TEST ..............................................................................24
PROGRAMMING 25
REMOTE CONTROLS (NOT PROVIDED) .................................................25
LIFTMASTER INTERNET GATEWAY
(NOT PROVIDED) ....................................................................................26
ERASE ALL CODES .................................................................................26
ERASE LIMITS ........................................................................................26
TO REMOVE AND ERASE MONITORED ENTRAPMENT PROTECTION
DEVICES .................................................................................................26
OPERATION 27
GATE OPERATOR SETUP EXAMPLES ....................................................27
CONTROL BOARD OVERVIEW ................................................................28
MANUAL RELEASE .................................................................................29
RESET BUTTON ......................................................................................29
PARTY MODE .........................................................................................29
OPERATOR ALARM ...............................................................................30
REMOTE CONTROL ................................................................................30
ACCESSORY WIRING 31
EXTERNAL CONTROL DEVICES ..............................................................31
VEHICLE DETECTION DEVICES ..............................................................31
LOCKS ....................................................................................................32
MISCELLANEOUS WIRING .....................................................................32
EXPANSION BOARD 33
EXPANSION BOARD OVERVIEW ............................................................33
AUXILIARY RELAYS ...............................................................................34
WIRING ACCESSORIES TO THE EXPANSION BOARD ............................35
MAINTENANCE 36
IMPORTANT SAFETY INFORMATION .....................................................36
MAINTENANCE CHART ...........................................................................36
BATTERIES .............................................................................................36
TROUBLESHOOTING 37
ERROR CODES .......................................................................................37
CONTROL BOARD LEDS .........................................................................40
TROUBLESHOOTING CHART ..................................................................41
APPENDIX 44
INSTALLATION TYPES ............................................................................44
POSITION THE BRACKETS .....................................................................44
SOLAR PANEL(S) ...................................................................................45
LIMIT SETUP WITH A REMOTE CONTROL .............................................50
SAMS WIRING WITH RELAYS NOT ENERGIZED ....................................51
REPAIR PARTS 52
LARGE METAL CONTROL BOX (XLM) ....................................................52
STANDARD CONTROL BOX ....................................................................52
GATE OPERATOR ARM ...........................................................................52
WIRING DIAGRAM 53
STANDARD CONTROL BOX ....................................................................53
LARGE METAL CONTROL BOX ...............................................................54
ACCESSORIES 55
WARRANTY 57
SAFETY
SAFETY SYMBOL AND SIGNAL WORD REVIEW
When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of Serious Injury or Death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock.
Read the warnings carefully.
When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your gate and/or the gate operator if you do not comply with the cautionary statements that accompany it. Read them carefully.
IMPORTANT NOTE:
• BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions.
• DO NOT attempt repair or service of your gate operator unless you are an Authorized
Service Technician.
1
MECHANICAL
ELECTRICAL
SAFETY
USAGE CLASS
CLASS I – RESIDENTIAL VEHICULAR GATE
OPERATOR
A vehicular gate operator (or system) intended for use in garages or parking areas associated with a residence of one-to four single families.
CLASS II – COMMERCIAL/GENERAL ACCESS
VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotel, garages, retail store, or other buildings accessible by or servicing the general public.
CLASS III – INDUSTRIAL/LIMITED ACCESS
VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not accessible by or intended to service the general public.
CLASS IV– RESTRICTED ACCESS VEHICULAR GATE
OPERATOR
A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.
I
III
II
IV
UL325 ENTRAPMENT PROTECTION REQUIREMENTS
This vehicular gate operator must be installed with at least two independent entrapment protection means as specified in the table below.
IMPORTANT SAFETY INFORMATION
HORIZONTAL SLIDE AND SWING GATE OPERATOR
Type A
GATE OPERATOR ENTRAPMENT PROTECTION TYPES
Inherent (built into the operator) entrapment protection system
Type B1
Type B2
Non-contact sensors such as photoelectric sensors
Contact sensors such as edge sensors
The same type of device shall not be used for both entrapment protection means. Use of a single device to cover both the opening and closing directions is in accordance with the requirement; however, a single device is not required to cover both directions.
This operator is provided with Type A. The installer is required to install additional entrapment protection devices in each entrapment zone.
To reduce the risk of INJURY or DEATH:
• READ AND FOLLOW ALL INSTRUCTIONS.
• NEVER let children operate or play with gate controls. Keep the remote control away from children.
• ALWAYS keep people and objects away from the gate. NO ONE
SHOULD CROSS THE PATH OF THE MOVING GATE.
• Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or reverse when an object activates the noncontact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of INJURY or DEATH.
• Use the emergency release ONLY when the gate is not moving.
• KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual.
Have a qualified service person make repairs to gate hardware.
• The entrance is for vehicles ONLY. Pedestrians MUST use separate entrance.
• SAVE THESE INSTRUCTIONS.
2
SAFETY
SAFETY INSTALLATION INFORMATION
1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component. Each gate system is specifically designed for an individual application.
2. Gate operating system designers, installers and users must take into account the possible hazards associated with each individual application. Improperly designed, installed or maintained systems can create risks for the user as well as the bystander. Gate systems design and installation must reduce public exposure to potential hazards.
3. A gate operator can create high levels of force in its function as a component part of a gate system. Therefore, safety features must be incorporated into every design. Specific safety features include:
• Edges Sensors (contact) • Guards for Exposed Rollers
• Photoelectric Sensors • Screen Mesh
• Vertical Posts • Instructional and Precautionary Signage
4. Install the gate operator only when: a. The operator is appropriate for the construction and the usage class of the gate.
b. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 6 feet (1.8 m) above the ground to prevent a 2-1/4 inches (6 cm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position.
c. All exposed pinch points are eliminated or guarded, and guarding is supplied for exposed rollers.
5. The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.
6. The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.
7. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.
8. Controls intended for user activation must be located at least 6 feet
(1.8 m) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use.
Exception: Emergency access controls only accessible by authorized personnel (e.g. fire, police) may be placed at any location in the line-of-sight of the gate.
9. The Stop and/or Reset (if provided separately) must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start.
10. A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible.
11. For a gate operator utilizing a non-contact sensor: a. Reference owner’s manual regarding placement of non-contact sensor for each type of application. See Install Entrapment
Protection section.
b. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving.
c. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier.
12. For a gate operator utilizing a contact sensor such as an edge sensor: a. One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading edge, trailing edge and post mounted both inside and outside of a vehicular horizontal slide gate.
b. A hard wired contact sensor shall be located and its wiring arranged so the communication between the sensor and the gate operator is not subject to mechanical damage.
c. A wireless device such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless device shall function under the intended end-use conditions.
d. One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the bottom edge of a swing gate is greater than 6 inches (152 mm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on the bottom edge.
e. One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm).
3
SAFETY
GATE CONSTRUCTION INFORMATION
Vehicular gates should be installed in accordance with ASTM F2200: Standard Specification for Automated Vehicular Gate Construction. For a copy, contact ASTM directly at 610-832-9585 or www.astm.org.
1. GENERAL REQUIREMENTS
1.1 Gates shall be constructed in accordance with the provisions given for the appropriate gate type listed, refer to ASTM F2200 for additional gate types.
1.2 Gates shall be designed, constructed and installed to not fall over more than 45 degrees from the vertical plane, when a gate is detached from the supporting hardware.
1.3 Gates shall have smooth bottom edges, with vertical bottom edged protrusions not exceeding 0.50 inches (12.7 mm) when other than the exceptions listed in ASTM F2200.
1.4 The minimum height for barbed tape shall not be less than 8 feet
(2.44 m) above grade and for barbed wire shall not be less than 6 feet (1.83 m) above grade.
1.5 An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator.
1.6 A gate latch shall not be installed on an automatically operated gate.
1.7 Protrusions shall not be permitted on any gate, refer to ASTM
F2200 for Exceptions.
1.8 Gates shall be designed, constructed and installed such that their movement shall not be initiated by gravity when an automatic operator is disconnected, in accordance with the following.
1.8.1 Vehicular horizontal slide gate. Shall not result in continuous, unimpeded movement in either lineal direction of its travel.
1.8.2 Vehicular horizontal swing gate. Shall not result in continuous, unimpeded movement in either direction along the arc of its path of travel.
1.9 For pedestrian access in the vicinity of an automated vehicular gate, a separate pedestrian gate shall be provided. The pedestrian gate shall be installed in a location such that a pedestrian shall not come in contact with a moving vehicular access gate. A pedestrian gate shall not be incorporated into an automated vehicular gate panel.
2. SPECIFIC APPLICATIONS
2.1 Any non-automated gate that is to be automated shall be upgraded to conform to the provisions of this specification.
2.2 This specification shall not apply to gates generally used for pedestrian access and to vehicular gates not to be automated.
2.3 Any existing automated gate, when the operator requires replacement, shall be upgraded to conform to the provisions of this specification in effect at that time.
3. VEHICULAR HORIZONTAL SLIDE GATES
3.1 The following provisions shall apply to Class I, Class II and Class
III vehicular horizontal slide gates:
3.1.1 All weight bearing exposed rollers 8 feet (2.44 m), or less, above grade shall be guarded or covered.
3.1.2 All openings shall be designed, guarded, or screened from the bottom of the gate to the top of the gate or a minimum of 72 in.
(1.83 m) above grade, whichever is less, to prevent a 2 1⁄4 in.
(57 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position. The gate panel shall include the entire section of the moving gate,including any back frame or counterbalance portion of the gate.
3.1.3 A gap, measured in the horizontal plane parallel to the roadway, between a fixed stationary object nearest the roadway, (such as a gate support post) and the gate frame when the gate is in either the fully open position or the fully closed position, shall not exceed 2 1/4 inches (57 mm), refer to ASTM F2200 for Exception.
3.1.4 Positive stops shall be required to limit travel to the designed fully open and fully closed positions. These stops shall be installed at either the top of the gate, or at the bottom of the gate where such stops shall horizontally or vertically project no more than is required to perform their intended function.
3.1.5 All gates shall be designed with sufficient lateral stability to assure that the gate will enter a receiver guide, refer to ASTM
F2200 for panel types.
3.2 The following provisions shall apply to Class IV vehicular horizontal slide gates:
3.2.1 All weight bearing exposed rollers 8 feet (2.44 m), or less, above grade shall be guarded or covered.
3.2.2 Positive stops shall be required to limit travel to the designed fully open and fully closed positions. These stops shall be installed at either the top of the gate, or at the bottom of the gate where such stops shall horizontally or vertically project no more than is required to perform their intended function.
4. VEHICULAR HORIZONTAL SWING GATES
4.1 The following provisions shall apply to Class 1, Class II and Class
III vehicular horizontal swing gates:
4.1.1 Gates shall be designed, constructed and installed so as not to create an entrapment area between the gate and the supporting structure or other fixed object when the gate moves toward the fully open position, subject to the provisions in 4.1.1.1 and
4.1.1.2.
4.1.1.1 The width of an object (such as a wall, pillar or column) covered by a swing gate when in the open position shall not exceed 4 inches (102 mm), measured from the center line of the pivot point of the gate, refer to ASTM F2200 for exception.
4.1.1.2 Except for the zone specified in Section 4.1.1.1, the distance between a fixed object such as a wall, pillar or column, and a swing gate when in the open position shall not be less than 16 inches (406 mm), refer to ASTM F2200 for exception.
4.2 Class IV vehicular horizontal swing gates shall be designed, constructed and installed in accordance with security related parameters specific to the application in question.
4
CARTON INVENTORY
NOT SHOWN: Documentation packet and hardware bag
INTRODUCTION
Warning Signs (2) and Warranty Card
Post Bracket Gate Bracket
Gate Operator
Key (2)
Standard Control Box with
Batteries 12 Vdc 7AH (2)
MODEL LA500DCS ONLY
Key (2)
Gate Operator
Post Bracket Gate Bracket Junction Box
Terminal Block
Connector
Watertight
Connector (2)
Extension Cable
Connector
OPTIONAL ACCESSORIES (ORDERED SEPARATELY)
Large Metal Control Box (Model LA500CONTXLMDC)
Ideal for installations that require additional room in the control box
(batteries not included). For 240 Vac applications an additional toroidal transformer kit is required (refer to accessories).
Large Metal Control Box for Solar Applications
(Model XLSOLARCONTDC)
Required for solar installations (batteries not included). Requires two
33AH batteries, battery tray, and solar battery harness (refer to accessories).
5
INTRODUCTION
SPECIFICATIONS
This model is intended for use in vehicular swing gate applications:
Usage Classification
Main AC Supply
System Operating Voltage
Class I, II, III, & IV
120 Vac, 2 Amps (8 Amps including Accessory Outlets)
OR
240 Vac, 1 Amp
24 Vdc Transformer Run / Battery Backup
Accessory Power
Solar Power Max
Maximum Gate Weight/Length
24 Vdc, 500mA max. for ON + SW (switched)
24 Vdc at 60 watts max.
1600 lbs. (725.7kg) / 8 ft (2.4 m)
800 lbs. (362.9 kg) / 16 ft (4.9 m)
600 lbs. (272.2 kg) / 18 ft (5.5 m)
15-18 seconds
115 degrees
90 Degree Travel Time*
Maximum Travel Range*
Maximum Daily Cycle Rate
Maximum Duty Cycle
Operating Temperature
Expansion Board
300 cycles / day
Continuous
-40°C to 60°C (-40°F to 140°F)
Provided
Inherent Entrapment Protection (Type A) Dual - RPM and Current Sense
External Entrapment Protection (Type B1 and/or Type B2) 3 inputs per board - any combination of up to 3 photoelectric sensors and up to 2 edge sensors
*Travel time and range are affected by A and B mounting dimensions
5-13/16" (14.8 cm)
4-3/16" (10.6 cm)
40-3/8" (102.6 cm)
16-7/16"
(41.8 cm)
Standard Control Box
20-3/4"
(52.7 cm)
Large Metal Control Box
14-3/8"
(36.5 cm)
6-9/16"
(16.7 cm)
17-3/16"
(43.7 cm)
6-3/16"
(15.7 cm)
6
INTRODUCTION
SITE PREPARATION
Check the national and local building codes BEFORE installation.
TRENCH
Trench and install conduit. Before trenching, contact underground utility locating companies. Conduit must be UL approved for low and high voltage.
LOOPS
Loops allow the gate to stay open when vehicles are obstructing the gate path. Suggested for vehicles 14 feet (4.27 m) or longer. Loops are not required but are recommended.
Conduit
SAFETY
Entrapment protection devices are required to protect against any entrapment or safety conditions encountered in your gate application (refer to pages 18-19 for more details). Install warning signs on both sides of the gate.
(Inside Property)
GATE
Gate must be constructed and installed according to ASTM F2200 standards (refer to page 4). Gate must fit specifications of operator
(refer to specifications).
Warning Signs
Entrapment Danger
CHECK YOUR GATE
Gate MUST be level. Gate and gate post MUST be plumb. Gate MUST have a smooth bottom edge, no protrusions should exist.
Remove ANY/ALL wheels from the bottom of gate.
Gate MUST NOT hit or drag across ground.
Gate MUST swing freely and be supported entirely by its hinges.
7
INTRODUCTION
OVERVIEW OF TYPICAL INSTALLATION
Identify your installation type (refer to the Appendix in the back of the manual for more information). All the illustrations on the following pages display a typical Left-Hand Gate installation with a pull-to-open bracket. For Push-to-Open applications refer to the Appendix.
SINGLE GATE
Control Box
Operator
Warning Sign
NOTE: One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists at either the opening or closing direction.
Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is still moving.
Edge Sensors
Photoelectric
Sensors
Water Tight Conduit (Not provided)
NOTE: Power and control wiring
MUST be run in separate conduits.
Earth Ground Rod
Check national and local codes for proper depth
DUAL GATE
Photoelectric
Sensors
Warning Sign
Edge Sensor
Secondary Operator
Junction
Box
Photoelectric Sensors
Control Box
Primary Operator
Warning Sign
Photoelectric Sensors
Edge Sensor
Photoelectric
Sensors
Water Tight Conduit (Not provided)
NOTE: Power and control wiring
MUST be run in separate conduits.
Earth Ground Rod
Check national and local codes for proper depth
Photoelectric Sensors
8
INSTALLATION
IMPORTANT SAFETY INFORMATION
To prevent SERIOUS INJURY or DEATH from a moving gate:
• Pinch points must be guarded at all times. Install enclosed-style gate tracks and roller guards.
• Place screen mesh 6 feet (1.8 m) high on the gate to prevent access through openings anywhere the gate may travel.
• Mount controls at least 6 feet (1.8 m) from the gate or ANY moving part of the gate.
• Install Warning signs on EACH side of gate in PLAIN VIEW.
Permanently secure each Warning sign in a suitable manner using fastening holes.
• This operator is intended for vehicular use only. To prevent INJURY to pedestrians, a separate pedestrian access should be supplied, visible from the gate. Locate the pedestrian access where there is not a chance of INJURY at any point during full movement of the gate.
• Contact sensors MUST be located at the leading and trailing edges, and post mounted both inside and outside a horizontal swing gate.
Non-contact sensors such as photoelectric sensors MUST be mounted across the gate opening and operate during BOTH the open and close cycles.
• Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate.
• Locate entrapment protection devices to protect in BOTH the open and close gate cycles.
• Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls.
• Too much force on gate will interfere with proper operation of safety reversal system.
• NEVER increase force beyond minimum amount required to move gate.
• NEVER use force adjustments to compensate for a binding or sticking gate.
• If one control (force or travel limits) is adjusted, the other control may also need adjustment.
• After ANY adjustments are made, the safety reversal system MUST be tested. Gate MUST reverse on contact with a rigid object.
• To AVOID damaging gas, power or other underground utility lines, contact underground utility locating companies BEFORE digging more than 18 inches (46 cm) deep.
• ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment.
INSTALLATION TIPS
DO's
• Weld a horizontal bar across entire gate on any installation for strength. Make sure that the operator is mounted level or it will not function properly.
• Make sure there is slack in the operator cable.
• The operator can be mounted on top of the gate frame.
• The operator must be installed at least 12 inches from the ground.
Operator Cable
!
!
DON'Ts
• DO NOT install upside down.
• DO NOT install next to sprinklers or any area that may expose the bottom of operator to water.
• DO NOT install on uphill or downhill gates.
• DO NOT install on ANY pedestrian passageways, doorways, or gates.
• DO NOT over-bend the operator cable. Doing this will cause the wires to eventually break.
• DO NOT weld the crossbar on just a few pickets, or they could bend.
9
INSTALLATION
STEP 1
NOTE: The ideal installation measurements are A = 7-3/4" (19.7 cm) and
B = 8-1/2" (21.6 cm). If different measurements are used, the sum of A and B cannot be greater than 18" (45.7 cm).
POSITION THE BRACKETS
If this operator is a replacement for a Miracle-One™ operator, use the existing post bracket and gate bracket. Remove the Miracle-One™ operator from the brackets and proceed to the next step.
If your application is Push-to-Open, refer to the illustrations in the
Appendix.
A
DIMENSION CHART
B
7-3/4" (19.7 cm)
8-1/2" (21.6 cm)
9" (22.9 cm)
9" (22.9 cm)
7-1/2" (19.1 cm)
8-1/2" (21.6 cm)
7-3/4" (19.7 cm)
9" (22.9 cm)
8-1/2" (21.6 cm)
7-1/2" (19.1 cm)
The measurements shown below are typical for a standard installation.
Your installation may be different. The gate bracket MUST be installed in an area that can withstand heavy forces. Additional reinforcement steel plates may be necessary for mounting.
1. Close the gate.
2. Choose a vertical mounting location for the post bracket.
3. Place a measuring tape under the center of the gate hinge point and measure out dimension A (see chart).
4. Use a screwdriver or dowel rod to temporarily mark the location of the first measurement (Figure 1).
5. Measure out dimension B (see chart) from the previous mark. Use a screwdriver to mark the location of the second measurement
(Figure 1).
6. Align the post bracket as close as possible above the screwdriver or dowel rod and tack weld the post bracket in the desired vertical position.
7. Position a level on the post bracket and measure 35-1/2 inches (90.2 cm) over from the center hole of the post bracket and mark the location on the gate (Figure 2).
8. Measure 2-1/4 inches (6.4 cm) down from the previous mark and center the bracket on this mark (Figure 3). Tack weld the gate bracket in this position.
NOTES:
• There should only be a maximum of 4" (10.2 cm) from the center of the hinge to the edge of the post or column (Figure 1). If the distance is greater than 4" (10.2 cm) entrapment protection for this area is required.
• While the gate is in the fully open position, the operator needs a clearance of 11-1/4" (28.6 cm) as shown (Figure 2).
FIGURE 1
4" (10.2 cm) maximum
(B)
Post Bracket Location
FIGURE 2
TOP VIEW OF CLOSED GATE
11-1/4" minimum
(28.6 cm)
(A)
Gate Bracket Location
35-1/2"
(90.2 cm)
Outside Property
Inside Property
Outside Property
6-1/2"
(16.5 cm)
Inside Property
FIGURE 3
Gate Bracket Location
2-1/4"
(6.4 cm)
10
INSTALLATION
STEP 2
ATTACH THE BRACKETS
1. Insert the key into the lock and turn it 180 degrees counterclockwise.
Turn the release lever 180 degrees counterclockwise. The operator is now in manual mode.
2. Position the operator on the brackets and make sure the operator is level and positioned correctly on the gate.
3. Remove the operator from the gate.
4. Completely weld around the post bracket and gate bracket.
NOTE: Brackets may need additional reinforcement by welding flat stock as shown.
5. Attach the operator to the post bracket with the bolt, mounting plate, and nut as shown.
6. Attach gate bracket to operator with the bolt, washer, and nut as shown. Tighten the nut until it reaches the bottom of the gate bracket, then turn the nut a half turn, making sure not to overtighten.
Make sure the trolley does not reach the fully open or fully closed position.
NOTE: Extra force may be needed to move the trolley back and forth.
Release Lever
Key
Post Bracket
For dual gate applications, repeat the previous installation steps to install the second operator.
11
Gate Bracket
INSTALLATION
STEP 3
INSTALL THE CONTROL BOX
For Large Metal Control Box installation, refer to the following page.
STANDARD CONTROL BOX
The control box MUST be mounted within 5 feet (1.52 m) of the gate operator. Mount the control box as high as possible for best radio reception. Make sure the control box is level. NOTE: The expansion board
DOES NOT need to be removed for a wall or column mount installation.
1. Remove the screws and open the control box.
2. Disconnect the "Main Board" connector from the expansion board.
3. Remove the expansion board by removing the screws.
4. Select the mounting holes (according to your application) and remove the knockouts using a screwdriver and hammer.
5. Secure the control box to mounting surface.
A. Wall or Column: Use the provided screws (4).
B. Post: Use U-bolts and rubber washers (not provided) to ensure a watertight seal. Make sure the U-bolts do not protrude more than
3/4 inch from the control box because this can short the control board.
6. Reinstall the expansion board and connect the "Main Board" connector to the expansion board.
WALL OR COLUMN MOUNT
9 1/8"
Expansion Board
POST MOUNT
6 3/8"
4 3/8"
3 7/8"
5 7/8"
4 7/8"
2 7/8"
13 3/4"
12 1/16"
"Main
Board"
Connector
12
INSTALLATION
STEP 3 continued...
INSTALL THE CONTROL BOX
LARGE METAL CONTROL BOX
The control box MUST be mounted within 5 feet (1.52 m) of the gate operator. Mount the control box as high as possible for best radio reception. Make sure the control box is level.
NOTE: The Large Metal Solar Control Box (Model XLSOLARCONTDC) does not have the electrical outlets or the expansion board shown in the images.
WALL OR COLUMN MOUNT
1. Open the control box. The control box door may be removed by opening the door 90°. Lift the door from the hinges and set aside until the installation is complete.
2. Remove the electrical outlet cover by loosening the screws and sliding the cover up.
3. Use knock outs located at the 4 corners of the control box and knock out using a screwdriver and hammer.
4. Secure the control box to mounting surface using the provided screws (4).
WALL OR COLUMN MOUNT
POST MOUNT POST MOUNT
NOTE: The post mount option is not recommended for the 33AH battery application.
1. Open the control box. The control box door may be removed by opening the door 90°. Lift the door from the hinges and set aside until the installation is complete.
2. The control box can be mounted to a post with 'U' bolts (refer to chart). The knock out will accommodate a 3/8" diameter 'U' bolt.
Select center mounting holes (top and bottom) and knock out using a screwdriver and hammer.
3. Secure the control box to mounting surface with U-bolts and rubber washers (not provided) to ensure a watertight seal.
TYPE AND SIZE
Standard 3" Round Pipe
Standard 4" Square Post
Standard 6" Square Post
'U' BOLT OPENING
3-1/2"
4"
6"
13
INSTALLATION
To reduce the risk of SEVERE INJURY or DEATH:
• ANY maintenance to the operator or in the area near the operator
MUST NOT be performed until disconnecting the electrical power (AC or solar and battery) and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service.
• Disconnect power at the fuse box BEFORE proceeding. Operator
MUST be properly grounded and connected in accordance with national and local electrical codes. NOTE: The operator should be on a separate fused line of adequate capacity.
• ALL electrical connections MUST be made by a qualified individual.
• DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram. We recommend that you install an edge sensor BEFORE proceeding with the control station installation.
• ALL power wiring should be on a dedicated circuit and well protected. The location of the power disconnect should be visible and clearly labeled.
• ALL power and control wiring MUST be run in separate conduit.
STEP 4
EARTH GROUND ROD
Use the proper earth ground rod for your local area. The ground wire must be a single, whole piece of wire. Never splice two wires for the ground wire. If you should cut the ground wire too short, break it, or destroy its integrity, replace it with a single wire length.
1. Install the earth ground rod within 3 feet of the control box.
2. Run wire from the earth ground rod to the control box. The earth ground wire will be connected in a later step.
NOTE: If the operator is not grounded properly the range of the remote controls will be reduced.
Control Box
12 Gauge Wire
Check national and local codes for proper depth
Earth Ground Rod (Within 3'
(0.9 m) of control box)
STEP 5
WIRE THE OPERATOR ARM TO THE
CONTROL BOARD
1. Choose a knockout in the bottom of the control box.
2. Insert the operator cable through the provided watertight connector.
3. Insert the operator cable and watertight connector into the knockout.
4. Slide the connector nut onto the operator cable.
5. Connect the operator cable wires to the connector according to the colored label on the connector (white to white, red to red, etc.).
6. Plug the connector into the GATE 1 terminal on the control board as shown.
(control board)
Connector
Operator Cable
Watertight
Connector
Connector
Nut
If installing one operator, proceed to page 18. If installing two operators, go to the following page.
14
INSTALLATION
STEP 6
DUAL GATES ONLY
There are two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use wired and
wireless communication simultaneously. Wired dual gate applications will have a longer battery standby time than wireless applications. Wireless dual gates will require the installation of two control boxes, one for each operator arm.
WIRELESS DUAL GATES
INSTALL A SECOND OPERATOR ARM AND CONTROL
BOX
Install a second operator arm and control box by following installation steps 1-5.
TO ACTIVATE THE WIRELESS FEATURE
1. Choose a control box to be the network primary operator. All wireless accessories will need to be programmed to the primary control board.
NOTE: We recommend that all accessories and board configurations are set on the primary control board.
2. Press and release the LEARN button on the primary control board.
The green XMITTER LED will light.
3. Press and release the LEARN button again on the primary control board. The yellow NETWORK LED will light.
4. Press and release the OPEN test button to assign this operator as network primary.
5. Press and release the LEARN button on the secondary control board.
The green XMITTER LED will light.
6. Press and release the LEARN button again on the secondary control board. The yellow NETWORK LED will light.
7. Press and release the CLOSE test button to assign this operator as network secondary.
Both operators will beep and the yellow NETWORK LEDs will turn off indicating programming is successful.
TO DEACTIVATE THE WIRELESS FEATURE:
1. Press and release the LEARN button on either control board. The green XMITTER LED will light.
2. Press and release the LEARN button again on the same control board.
The yellow NETWORK LED will light.
3. Press and hold the LEARN button for 5 seconds. The yellow
NETWORK LED will blink (operator will beep) then turn off indicating successful deactivation.
Repeat the steps for the other control board.
15
INSTALLATION
STEP 6 continued...
DUAL GATES ONLY
WIRED DUAL GATES
INSTALL A SECOND OPERATOR ARM
Install a second operator arm by following installation steps 1-2.
INSTALL THE EXTENSION CABLE AND JUNCTION
BOX
Before digging, contact local underground utility locating companies.
1. Trench across driveway to bury the extension cable. Use PVC conduit to prevent damage to cables.
2. Open the junction box by removing screws (4) and set aside.
3. Select holes to be used for mounting and knock out using a screwdriver and hammer. Drill two holes in the junction box large enough for the watertight connectors.
4. Mount the junction box within 3 feet (0.9 m) of second operator.
5. Route operator cable and extension cable through watertight connector nut and watertight connector.
6. Insert the cables and watertight connectors into the holes in the junction box.
5. Slide the connector nut onto the operator cable and extension cable.
8. Connect the wires from extension cable and operator cable to the terminal block connector as shown (like-colored wires must face each other).
9. Put wires inside of junction box.
10. Secure operator and extension cables by tightening the connector nut.
11. Reinstall cover.
Operator
Cable
Connector Nut
Watertight
Connector
Brown
Green
White
Yellow
Blue
Red
Terminal Block
Brown
Green
White
Yellow
Blue
Red
Extension
Cable
Watertight Connector Nut
Junction Box
Within 3' (0.9 m)
PVC Conduit
16
INSTALLATION
STEP 6 continued...
DUAL GATES ONLY
WIRED DUAL GATES
(Control Board)
WIRE THE SECONDARY OPERATOR ARM TO THE
CONTROL BOARD
1. Choose a knockout in the bottom of the control box.
2. Insert the extension cable through the watertight connector.
3. Insert the extension cable and watertight connector into the knockout.
4. Slide the connector nut onto the operator cable.
5. Connect the extension cable wires to the connector according to the colored label on the connector (white to white, red to red, etc.).
6. Plug the connector into the GATE 2 terminal on the control board as shown.
Watertight
Connector
Extension
Cable
Connector Nut
Connector
Extension Cable
(from secondary operator)
Primary Operator Secondary Operator
SET THE BIPART DELAY (SINGLE CONTROL BOX)
Occasionally in dual gate installations, one gate will need to open first and close second. This would happen if there was an ornamental overhang on one gate or if using a solenoid lock, for example. This gate is called the
Primary gate and needs to be connected to Gate 1 connections on the control board. Thus, it is preferred that the control box be installed on the same side as this gate. If there is no appropriate location on that side for the control box, then mount the control box on the opposite side, but connect the operator closest to the control box to the Gate 2 connector and the operator on the opposite side to the Gate 1 connector.
1. The BIPART DELAY switch on the control board needs to be set to the ON position.
The following illustration shows a dual gate configuration with a decorative overlapping piece on the outside of the gate.
SET THE BIPART DELAY (DUAL CONTROL BOX)
BIPART DELAY/SYNCHRONIZED CLOSE
The LOCK/BIPART DELAY switch is used with dual control box applications and serves two functions:
• BIPART DELAY: The BIPART DELAY is used in applications where a mag-lock, solenoid lock, or decorative overlay would require one gate to close before the other. The control box with the LOCK/BIPART
DELAY switch ON will delay from the close limit when opening and be the first to close from the open limit.
• SYNCHRONIZED CLOSE: The BIPART DELAY is also used in applications where one gate travels a longer distance than the other.
To synchronize the closing of the gates, set the LOCK/BIPART DELAY switch to ON for both control boxes.
17
Primary Gate
OUTSIDE PROPERTY
Primary Gate - Connect to Gate 1 Connector on
Control Board.
INSTALLATION
To prevent SERIOUS INJURY or DEATH from a moving gate:
• Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate.
• Locate entrapment protection devices to protect in BOTH the open and close gate cycles.
• Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls.
STEP 7
INSTALL ENTRAPMENT PROTECTION
At least one external monitored entrapment protection device is required prior to gate movement (effective January of 2016). A monitored device sends a pulsed signal to the operator so the operator is aware of the device. If the operator does not receive the signal from the device it will not run.
An entrapment zone is every location or point of contact where a person can become entrapped between a moving gate and a stationary object. All gate operator systems REQUIRE two independent entrapment protection systems for each entrapment zone. This operator contains an inherent
(internal) entrapment protection system and REQUIRES the addition of an external entrapment protection system (non-contact photoelectric sensor or contact edge sensor) for EACH entrapment zone.
Your application may contain one or many entrapment zones. Property owners are obligated to test entrapment protection devices monthly.
NON-CONTACT SENSORS
If the photoelectric sensor beam gets blocked while the gate is moving, the gate will stop and reverse for 4 seconds. The gate will not be able to travel in that direction until the obstruction is cleared. CPS-UN4 or CPS-RPEN4GM monitored photoelectric sensors MUST be used. If a monitored photoelectric sensor is not working or loses power or the beam is blocked, then ALL gate operation in that direction will stop.
Sensors for Open Cycle
NOTE: If the distance between the open gate and the wall is less than
16" (40.6 cm) entrapment protection for this area is required.
Monitored Photoelectric Sensors
(Outside Property)
(Inside Property)
Sensors for Close Cycle
18
INSTALLATION
STEP 7 continued...
INSTALL ENTRAPMENT PROTECTION
There are three options for wiring the entrapment protection devices depending on the specific device and how the device will function. Refer to the wiring diagram or the specific entrapment protection device manual for more information. These entrapment protection device inputs are for monitored devices, which include pulsed photoelectric sensors, resistive edge sensors, and pulsed edge sensors. NOTE: Only one monitored entrapment protection device may be wired to each input.
CLOSE EYES/INTERRUPT (2 Terminals)
The CLOSE EYES/INTERRUPT input is for photoelectric sensor entrapment protection for the close direction. When an obstruction is sensed during gate closing the gate will open to the full open position and resets the Timer-to-Close. This input will be disregarded during gate opening.
CLOSE EDGE (2 Terminals)
The CLOSE EDGE input is for edge sensor entrapment protection for the close direction. When an obstruction is sensed during gate closing the gate will reverse for 4 seconds then stop, disengaging the Timer-to-Close.
This input will be disregarded during gate opening.
OPEN EYES/EDGE (2 Terminals)
The OPEN EYES/EDGE input is for photoelectric sensor or edge sensor entrapment protection for the open direction. When an obstruction is sensed during gate opening the gate will reverse for 4 seconds then stop.
This input will be disregarded during gate closing.
Close Photoelectric Sensors
Close Edge
Open Photoelectric Sensors OR Open Edge
19
INSTALLATION
STEP 8
POWER WIRING
The standard control box can be wired for either 120 Vac or 240 Vac.
Factory default is 120 Vac. The Large Metal Control Box (XLM) can be wired for 120 Vac (default).
The batteries are charged in the circuit by the toroid transformer, plug-in transformer, or the solar panels. Main power supply and control wiring MUST be run in separate conduits.
SOLAR APPLICATIONS: For solar applications refer to Solar Panels section in the Appendix, pages 45-49. Follow the directions according to your application.
NOTE: If using an external receiver use shielded wire for the connections or mount the receiver away from the operator to avoid interference with the operator.
OPERATOR POWER SOURCE
120 VAC
Wire Gauge 14
Wire Gauge 12
Wire Gauge 10
350 feet (107 m)
525 feet (160 m)
850 feet (259 m)
OR
240 VAC
Wire Gauge 14
Wire Gauge 12
Wire Gauge 10
1,150 feet (351 m)
1,850 feet (564 m)
2,950 feet (899 m)
NOTE: Use copper conductors ONLY.
STANDARD CONTROL BOX
STANDARD CONTROL BOX
1. Turn off the AC power from the main power source circuit breaker.
2. Run the AC power wires to the control box.
3. Remove the toroid assembly from the control box by loosening the four screws and lifting the assembly up and out.
4. Ensure the 120/240 plug is connected to either the 120 or 240 Vac connector on the EMI board depending on your application. Factory default is 120 Vac.
5. Connect the ground wire to the ground screw on the back of the toroid assembly.
6. Connect the white wire from the toroid assembly to NEUTRAL using a wire nut.
7. Connect the black wire from the toroid assembly to HOT using a wire nut.
8. Replace the toroid assembly and tighten the four screws. Ensure the wires are not pinched.
9. Plug the J15 plug into the control board. The control board will power up. NOTE: You may see a small spark when plugging the J15 plug into the board.
10. Turn ON AC power to the operator.
Toroid
Assembly
J15 Plug
240 Vac
Connector
120 Vac
Connector
Ground
Screw
(back view of toroid assembly)
(incoming power wires)
20
INSTALLATION
STEP 8 continued...
POWER WIRING
LARGE METAL CONTROL BOX
To use solar panels with the Large Metal Control Box (Model
XLSOLARCONTDC) skip the steps below and refer to the Solar Panels section in the Appendix, pages 45-49.
1. Turn OFF AC power to the operator at the circuit breaker and unplug the transformer.
2. Run the AC power wires to the control box.
3. Remove the junction box cover.
4. Connect the green wire to the earth ground rod wire using a wire nut.
5. Connect the white wire to NEUTRAL using a wire nut.
6. Connect the black wire to HOT using a wire nut.
7. Replace the junction box cover. Ensure the wires are not pinched.
8. Unplug the J15 plug labeled BATT(-)(+) DC(-)(+) on the control board by squeezing the plug and pulling it from the control board.
9. Connect a jumper between the positive (+) terminal of one battery to the negative (-) terminal of the other battery.
10. Connect the red wire from the J15 plug labeled BATT (+) to the positive (+) terminal of the battery.
11. Connect the black wire from the J15 plug labeled BATT (-) to the negative (-) terminal of the battery.
12. Plug the J15 plug into the control board. The control board will power up. NOTE: You may see a small spark when plugging the J15 plug into the board.
13. Plug the transformer in.
14. Turn ON AC power.
LARGE METAL CONTROL BOX (LA500CONTXLMDC)
Junction Box
Cover
J15 Plug
Red Wire
Jumper
Black
Wire
21
INSTALLATION
STEP 9
FINISH INSTALL
1. Turn the release lever clockwise 180° back to the engaged position.
This engages the motor.
2. Turn the key clockwise 180°. This locks the release lever. The operator is now engaged.
3. Fasten warning signs to the gate with cable ties. Warning signs
MUST be installed on both sides of the gate and in plain view.
Release Lever
Key
LIMIT AND FORCE ADJUSTMENT
ADJUSTMENT
To reduce the risk of SEVERE INJURY or DEATH:
• Without a properly installed safety reversal system, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a moving gate.
• Too much force on gate will interfere with proper operation of safety reversal system.
• NEVER increase force beyond minimum amount required to move gate.
• NEVER use force adjustments to compensate for a binding or sticking gate.
• If one control (force or travel limits) is adjusted, the other control may also need adjustment.
• After ANY adjustments are made, the safety reversal system MUST be tested. Gate MUST reverse on contact with a rigid object.
INTRODUCTION
Your operator is designed with electronic controls to make travel limit and force adjustments easy. The adjustments allow you to program where the gate will stop in the open and close position. The electronic controls sense the amount of force required to open and close the gate. The force is adjusted automatically when you program the limits but should be fine tuned using the REVERSAL FORCE dial on the control board (refer to Fine Tune the Force section) to compensate for environmental changes.
The limits can be set using the control board (following page) or a remote control (refer to Limit Setup with a Remote Control in the Appendix).
Setting the limits with a remote control requires a 3-button remote control programmed to OPEN, CLOSE, and STOP.
NOTE: The Test Buttons on the control board will not work until the limits have been set.
22
ADJUSTMENT
LIMIT AND FORCE ADJUSTMENT continued...
For dual gate applications the limits will have to be set for each operator. The gate MUST be attached to the operator before setting the limits and force.
INITIAL LIMITS AND FORCE ADJUSTMENT
If a mistake is made while programming the limits press the reset button to start over.
1. Set the GATE switch to the 1 position.
2. Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode.
3. Press and hold the MOVE GATE buttons to move the gate to the open or close limit.
4. Press and release the SET CLOSE or SET OPEN button depending on which limit is being set.
5. Press and hold the MOVE GATE button to move the gate to the other limit.
6. Press and release the SET CLOSE or SET OPEN button depending on which limit is being set. The operator will exit limit setting mode.*
7. Cycle the gate open and close using the TEST BUTTONS. This automatically sets the force.
8. For dual gates set the Gate switch to the 2 position and repeat steps
2-7.
When limits are set properly the operator will automatically exit limit setting mode.
* Dual Gates ONLY: When the limits are set on the secondary gate first the control board will not exit the limit setting mode until the limits are set on the primary gate.
1
E
E
CLOSE Limit
RELEASE
TO BEGIN
LIMIT
SETUP
1
2
GATE
5
OFF
TIMER
TO CLOS
(SECONDS)
10
2
SET OPEN SET CLOSE
OFF
RELEASE
TO BEGIN
LIMIT
SETUP
B
D
3
MOVE
GATE
OPEN Limit
SET OPEN SET CLOSE
7
RELEASE
TO BEGIN
LIMIT
SETUP
MOVE
GATE
TI
TO
(SE
6
RELEASE
TO BEGIN
LIMIT
SETUP
1
2
GATE
SET OPEN SET CLOSE
RELEASE
TO BEGIN
LIMIT
SETUP
RELEASE
TO BEGIN
LIMIT
SETUP
1
TI
TO
(SE
5
2
GATE
4
SET OPEN
LED
LIMIT SETUP LEDS
SET CLOSE
LED
OPERATOR MODE EXPLANATION
OFF OFF NORMAL MODE Limits are set.
BLINKING BLINKING LIMIT SETTING MODE Limits are not set.
BLINKING ON LIMIT SETTING MODE Open limit is not set.
ON
ON
BLINKING LIMIT SETTING MODE Close limit is not set.
ON LIMIT SETTING MODE Limits are set.
23
ADJUSTMENT
LIMIT AND FORCE ADJUSTMENT continued...
FINE TUNE THE FORCE
The REVERSAL FORCE DIAL on the control board is used for fine tuning the force in cases where wind or environmental changes may affect the gate travel.
Based on the length and weight of the gate it may be necessary to make additional force adjustments. The force setting should be high enough that the gate will not reverse by itself nor cause nuisance interruptions, but low enough to prevent serious injury to a person. The force setting is the same for both the open and close gate directions.
1. Open and close the gate with the test buttons.
2. If the gate stops or reverses before reaching the fully open or closed position, increase the force by turning the force control slightly clockwise.
3. Perform the “Obstruction Test” after every force setting adjustment
(see below).
1
XMITTER
NETWORK
RSAL
RCE
TEST
BUTTONS
SE
NETWORK
REVERSAL
FORCE
2
60
180 MIN
BATT LOW
MAX
NG ACC PWR OVLD
DIAG
C
ADJUST THE LIMITS
After both limits are set and the operator is ready to run, one limit can be adjusted independently from the other by following steps 1-3 of the Initial
Limit and Force Adjustment section, on page 23.
SET OPEN SET CLOSE
PRESS &
RELEASE
OBSTRUCTION TEST
The operator is equipped with an automatic obstruction sensing feature.
If the gate encounters an obstruction during motion, the operator will automatically reverse direction of the gate for a short time and then stop the gate. After any adjustments are made, test the operator:
1. Open and close the gate with the test buttons, ensuring that the gate is stopping at the proper open and close limit positions.
2. Place a solid object between the open gate and a rigid structure.
Ensure that the gate, the solid object, and the rigid structure can withstand the forces generated during this obstruction test.
3. Run the gate in the close direction. The gate should stop and reverse upon contact with the solid object. If the gate does not reverse off the solid object, reduce the force setting by turning the force control slightly counter-clockwise. The gate should have enough force to reach both the open and close limits, but MUST reverse after contact with a solid object.
4. Repeat the test for the open direction.
1
2
XMITTER
NETWORK
RSAL
RCE
TEST
BUTTONS
3
CLOSE Limit
OPEN Limit
24
PROGRAMMING
REMOTE CONTROLS (NOT PROVIDED)
A total of 50 Security✚ 2.0™ remote controls and 2 keyless entries (1
PIN for each keyless entry) can be programmed to the operator. When programming a third keyless entry to the operator, the first keyless entry will be erased to allow the third keyless entry to be programmed. When the operator’s memory is full it will exit the programming mode and the remote control will not be programmed. The memory will need to be erased before programming any additional remote controls.
NOTE: If installing an 86LM to extend the range of the remote controls DO NOT straighten the antenna.
There are 3 different options for programming the remote control depending on how you would like the remote control to function.
Choose a programming option:
LEARN T
BUT
XMITTER
NETWORK
REVERSAL
FORCE
XMITTER
NETWORK
RSAL
RCE
TEST
BUTTONS
OPTION
Single button as OPEN only
Single button (SBC) as
OPEN, CLOSE, and
STOP
Three separate buttons as OPEN, CLOSE, and
STOP
DESCRIPTION
Program a single button on the remote control for open only. The
Timer-to-Close can be set to close the gate.
PROGRAMMING STEPS
1. Press and release the LEARN button (operator will beep and green XMITTER
LED will light).
Program one remote control button as an open, close, and stop.
2. Press the OPEN button.
3. Press the remote control button that you would like to program.
1. Press and release the LEARN button (operator will beep and green XMITTER
LED will light).
Program each remote control button as an open, close, and stop.
2. Press the remote control button that you would like to program.
1. Press and release the LEARN button (operator will beep and green XMITTER
LED will light).
2. Press the OPEN, CLOSE, or STOP button, depending on the desired function.
3. Press the remote control button that you would like to program.
The operator will automatically exit learn mode (operator will beep and green XMITTER LED will go out) if programming is successful. To program additional Security✚ 2.0™ remote controls or remote control buttons, repeat the programming steps above.
NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment or modifications of this transceiver are prohibited. THERE ARE NO USER SERVICEABLE PARTS. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC rules and IC RSS-210. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This Class B digital apparatus complies with Canadian ICES-003.
25
PROGRAMMING
LIFTMASTER INTERNET GATEWAY
(NOT PROVIDED)
USING THE RESET BUTTON ON THE OPERATOR
1. Connect the ethernet cable to the LiftMaster Internet Gateway and the router.
2. Connect power to the LiftMaster Internet Gateway.
3. Create an online account by visiting www.myliftmaster.com.
4. Register the LiftMaster Internet Gateway.
5. Use an internet enabled computer or smartphone to add devices. The
LiftMaster Internet Gateway will stay in learn mode for three minutes.
6. Ensure gate is closed.
7. Give the operator an OPEN command.
8. Within 30 seconds, when the gate is at the open limit press and release the reset button 3 times (on primary gate) to put primary operator into High Band Learn Mode (the operator will beep as it enters learn mode). The LiftMaster Internet Gateway will pair to the operator if it is within range and the operator will beep if programming is successful.
The status as shown by the LiftMaster Internet Gateway app will be either
“open” or “closed”. The gate operator can then be controlled through the
LiftMaster Internet Gateway app.
ERASE ALL CODES
To program the operator to the LiftMaster Internet Gateway:
USING THE LEARN BUTTON ON THE OPERATOR’S
CONTROL BOARD
1. Connect the ethernet cable to the LiftMaster Internet Gateway and the router.
2. Connect power to the LiftMaster Internet Gateway.
3. Create an online account by visiting www.myliftmaster.com.
4. Register the LiftMaster Internet Gateway.
5. Use an internet enabled computer or smartphone to add devices. The
LiftMaster Internet Gateway will stay in learn mode for three minutes.
6. Press the Learn button twice on the primary operator (the operator will beep as it enters learn mode). The LiftMaster Internet Gateway will pair to the operator if it is within range and the operator will beep if programming is successful.
OR
1. Press and release the LEARN button (operator will beep and green
XMITTER LED will light).
2. Press and hold the LEARN button again until the green XMITTER LED flashes and then release the button (approximately 6 seconds). All remote control codes are now erased.
ERASE LIMITS
1. To erase the limits, press and hold the SET OPEN and SET CLOSE buttons simultaneously (5 seconds) until both the SET OPEN and
SET CLOSE LEDs blink rapidly and the operator beeps.
2. Release the buttons and the SET OPEN and SET CLOSE LEDs will blink slowly indicating the limits will need to be set.
TO REMOVE AND ERASE MONITORED
ENTRAPMENT PROTECTION DEVICES
1. Remove the entrapment protection device wires from the terminal block.
2. Press and release the SET OPEN and SET CLOSE buttons simultaneously. The SET OPEN and SET CLOSE LEDs will turn on
(entering learn limit mode).
3. Press and release both SET OPEN and SET CLOSE buttons again to turn off the SET OPEN and SET CLOSE LEDs (exiting learn limit mode).
26
OPERATION
GATE OPERATOR SETUP EXAMPLES
The following are example setups for the gate operator. Your specific site requirements may be different. Always setup the operator system to the site requirements, including all necessary entrapment protection devices.
RESIDENTIAL: One to four residential homes sharing a gated entrance/exit, allowing vehicle access trumps security concerns
COMMERCIAL/GENERAL ACCESS: A residential community (more than four homes) having one or more gated entrances/exits, allowing vehicle access trumps security concerns
COMMERCIAL: Business site where security (gate closed) is important
INDUSTRIAL: Large business site where security is required
SETTING
Quick Close switch setting
AC Fail switch setting
RESIDENTIAL
Normally set to OFF.
Normal gate close (timer or control).
Normally set to BATT.
Run on battery if AC power fails.
COMMERCIAL/GENERAL ACCESS
Normally set to OFF. Normal gate close (timer or control).
Normally set to BATT. For local jurisdiction requirement, set to OPEN so that the gate will open approximately 15 seconds after AC power fail.
COMMERCIAL
Normally set to OFF.
Normal gate close (timer or control).
Normally set to BATT.
Run on battery if AC power fails.
INDUSTRIAL
Set to ON, so that gate closes immediately after vehicle passes interrupt loop.
Normally set to BATT. Run on battery if AC power fails.
Low Battery switch setting
Anti-Tail switch setting
Normally set to OPEN. If powered from battery and battery is low, gate automatically opens and stays open.
Normally set to OFF.
Interrupt loop reverses a closing gate.
Normally set to OPEN. If powered from battery and battery is low, gate automatically opens and stays open.
Normally set to OFF. Interrupt loop reverses a closing gate.
Bipart Delay switch setting
Aux Relay Out –
Open Limit Switch
For DUAL-GATE site, set to ON for gate that delays upon opening.
Typically not required.
For DUAL-GATE site, set to ON for gate that delays upon opening.
Use with SAMS (Sequence Access
Management System).
Aux Relay Out –
Close Limit Switch
Typically not required.
Typically not required.
Aux Relay Out –
Gate Motion
Aux Relay Out –
Pre-Motion Delay
Aux Relay Out –
Power
Aux Relay Out –
Tamper
Attach alert signal
(audible or visual alert system).
Attach alert signal
(audible or visual alert system).
Attach visual alert to know when system is charging batteries (i.e. not running on batteries).
Cycle Quantity
Feedback
Use during servicing only to determine operator cycles.
Fire Dept Open input Typically not required.
Attach alert signal (audible or visual alert system).
Attach alert signal (audible or visual alert system).
Attach visual alert to know when system is charging batteries (i.e. not running on batteries).
Attach alert signal
(audible or visual alert system) to indicate if gate is manually tampered with by being pushed off of close limit.
Attach alert signal (audible or visual alert system) to indicate if gate is manually tampered with by being pushed off of close limit.
Use during servicing only to determine operator cycles.
Connect emergency access system
(Knox box switch, SOS system, etc.)
27
Normally set to CLOSE. If powered from battery and battery is low, gate stays closed.
Normally set to CLOSE. If powered from battery and battery is low, gate stays closed.
Set to ON. In attempt to prevent vehicle tail-gating, interrupt loop pauses a closing gate.
Set to ON. In attempt to prevent vehicle tail-gating, interrupt loop pauses a closing gate.
For DUAL-GATE site, set to ON for gate that delays upon opening.
1) Use with SAMS
(Sequence Access
Management System)
2) Connect “Gate Open” indicator (e.g. light)
Connect “Gate Close/
Secure” indicator (e.g. light).
For DUAL-GATE site, set to
ON for gate that delays upon opening.
1) Use with SAMS
(Sequence Access
Management System)
2) Connect “Gate Open” indicator (e.g. light)
Connect “Gate Close/Secure” indicator (e.g. light).
Attach alert signal (audible or visual alert system).
Attach alert signal (audible or visual alert system).
Attach alert signal (audible or visual alert system).
Attach alert signal (audible or visual alert system).
Attach visual alert to know when system is charging batteries (i.e. not running on batteries).
Attach visual alert to know when system is charging batteries (i.e. not running on batteries).
Attach alert signal (audible or visual alert system) to indicate if gate is manually tampered with by being pushed off of close limit.
Attach alert signal (audible or visual alert system) to indicate if gate is manually tampered with by being pushed off of close limit.
Use during servicing only to determine operator cycles.
Typically not required.
Use during servicing only to determine operator cycles.
Typically not required.
OPERATION
CONTROL BOARD OVERVIEW
1 SET OPEN Button: The SET OPEN button sets the OPEN limit. See Adjust Limits section.
2 SET CLOSE Button: The SET CLOSE button sets the CLOSE limit. See Adjust Limits section.
3 MOVE GATE Buttons: The MOVE GATE buttons will either open or close the gate when the operator is in Limit setting mode. See Adjust Limits section.
• When AC power is OFF and battery voltage is critically low the gate will latch at a limit until AC power is restored or batteries voltage increases.
• Option select switch set to OPEN forces gate to automatically open and then latch at the OPEN limit until AC power is restored or battery voltage increases.
• Option select switch set to CLOSE forces gate to latch at CLOSE limit if at CLOSE limit or on next CLOSE command until AC power restored or battery voltage increases.
• Constant pressure on a hard command input overrides to open or close the gate.
• Critically low battery is less than 23 V
5 BIPART DELAY Switch: The LOCK/BIPART DELAY switch is used only for dual gates. See Bipart Delay section.
set to OFF. If the TTC is set to the OFF position, then the gate will remain open until the operator receives another command from a control. Rotate the
TIMER-TO-CLOSE dial to the desired setting. The range is 0 to 180 seconds, 0 seconds is OFF.
NOTE: Any radio command, single button control, or CLOSE command on the control board prior to the TTC expiring will close the gate. The TTC is reset by any signals from the open controls, loops, close edges, and close photoelectric sensors (IR’s).
8 REVERSAL FORCE dial: The REVERSAL FORCE dial adjusts the force. See Force Adjustment section.
11 Error Code Display: The error code display will show the operator type, firmware version, and error codes. The operator type will display as "LA" followed by a "50" which indicates the operator type as LA500DC. The firmware version will show after the operator type, example "1.2".
1 2 4 5 6 9
3
11
7
8
10
28
OPERATION
MANUAL RELEASE
In case of a power failure, the operator can be disengaged from the gate.
With an operator, the release action may sometimes feel stiff/jerky, which is normal and has no effect on function. NOTE: It is normal for the operator to run slow right after a disconnect or complete loss of AC/ battery power (the operator will need to run a complete open and close cycle).
RELEASE
1. Insert the key into the lock.
2. Turn the key counter-clockwise 180°.
3. Turn the release lever counter-clockwise 180°.
Operator is in manual mode and the gate can be opened and closed manually.
ENGAGE
1. Turn the release lever clockwise 180°. This engages the motor.
2. Turn the key clockwise 180°. This locks the release lever.
3. Remove the key and store in a safe place. The operator is now engaged.
RESET BUTTON
The reset button is located on the side of the control box and serves several functions:
• Press the reset button to stop a moving gate during a normal open/ close cycle, like a stop button.
• Press the reset button once while the gate is in open position to disable the Timer-to-Close. The gate will stay in the open position. To restart the Timer-to-Close either press the reset button or activate the gate with a programmed remote control.
• Press the reset button to shut off the alarm and reset the operator.
PARTY MODE
Press the reset button once while the gate is in open position to disable the Timer-to-Close. The gate will stay in the open position. To restart the
Timer-to-Close either press the reset button or activate the gate with a programmed remote control.
Reset Button
29
OPERATION
OPERATOR ALARM
If a contact sensor detects an obstruction twice consecutively the alarm will sound (up to 5 minutes) and the operator will need to be reset.
When the inherent force of the operator (RPM/current sensor) detects the following (twice consecutively) the alarm will sound (up to 5 minutes) and the operator will need to be reset:
A. The operator arm or gate is incorrectly installed.
B. The gate does not meet specifications.
C. Gate hinges are too tight or broken and the gate is not moving freely.
D. The gate is moving and a car pushes the gate.
E. A foreign object is on the gate frame while the gate is moving.
F. The gate hits the driveway, curb or other, and gets stuck or bent in an awkward position.
Remove any obstructions. Press the reset button to shut off the alarm and reset the operator. After the operator is reset, normal functions will resume.
The operator alarm will beep 3 times with a command if the battery is low.
A
C
E
REMOTE CONTROL
SINGLE BUTTON CONTROL (SBC) FUNCTIONALITY
Once the remote control has been programmed the operator will operate as follows:
When gate is in the closed position, activation of the remote control button will open the gate. During the open cycle another activation of the remote control will stop the gate and the next activation of the remote control will close the gate.
When the gate is in the open position, activation of the remote control button will close the gate. If the remote control is activated while the gate is closing, the gate will stop and the next activation will open the gate.
D
F
B
30
ACCESSORY WIRING
EXTERNAL CONTROL DEVICES
EXIT (2 Terminals)
This input is a soft open command (maintained switch does not override external safeties and does not reset alarm condition). Used for exit probe, telephone entry, external exit loop detector, or any device that would command the gate to open.
• Opens a closing gate and holds open an open gate, if maintained, pauses Timer-to-Close at OPEN limit.
SHADOW (2 Terminals)
This input is used for external shadow loop detector when loop is positioned under the swing of the gate.
• Holds open gate at open limit
• Only active when the gate is at the OPEN limit, disregarded at all other times
• Pauses Timer-to-Close at OPEN limit
INTERRUPT (2 Terminals)
This input is used for photoelectric sensors and external interrupt loop detector when loop is on the outside of the gate.
• Holds open gate at open limit
• Stops and reverses a closing gate to open limit
• Pauses Timer-to-Close at OPEN limit, activates quick close and anti-tailgate features when enabled on the expansion board
VEHICLE DETECTION DEVICES
The same accessory inputs used for vehicle detection devices are also used for entrapment protection devices (refer to step 7 of Installation).
The vehicle detection devices may be monitored or non-monitored, but only ONE monitored device may be connected to each input, inclusive of entrapment protection devices. Multiple non-monitored devices can be wired to the same input. A monitored device sends a pulsed signal to the operator so the operator is aware of the device. If the operator does not receive the signal from the device indicating it is working properly, it will not run in that direction.
CLOSE EYES/INTERRUPT (2 Terminals)
The CLOSE EYES/INTERRUPT input is for photoelectric sensor vehicle detection for the close direction. When an obstruction is sensed during gate closing the gate will open to the full open position. This input will be disregarded during gate opening and resets the Timer-to-Close.
CLOSE EDGE (2 Terminals)
The CLOSE EDGE input is for edge sensor vehicle detection for the close direction. When an obstruction is sensed during gate closing the gate will reverse for 4 seconds then stop, disengaging the Timer-to-Close. This input will be disregarded during gate opening.
OPEN EYES/EDGE (2 Terminals)
The OPEN EYES/EDGE input is for photoelectric sensor or edge sensor vehicle detection for the open direction. When an obstruction is sensed during gate opening the gate will reverse for 4 seconds then stop. This input will be disregarded during gate closing.
31
(control board)
Exit
Com
Shadow
Com
Interrupt
Com
Exit Loop
Interrupt Loop
Shadow Loop
Close Photoelectric Sensors
Close Edge
Open Photoelectric Sensors OR Open Edge
ACCESSORY WIRING
LOCKS
MAGLOCK (2 Terminals, N.C. and COM)
Relay contact output, Normally - closed (N.C.) output for maglocks.
Relay activates prior to motor activation and during motor run. Relay is off when motor is off.
NOTE: For AC power install a Siemens S10K30 MOV (Metal Oxide
Varistor) or equivalent. For DC power install a 1N4005 diode or equivalent.
(control board)
SOLENOID (2 Terminals, N.O. and COM)
Normally - open (N.O.) output for solenoid locks
Relay activates prior to motor activation and during motor run. Relay is off when motor is off.
NOTE: For AC power install a Siemens S10K30 MOV (Metal Oxide
Varistor) or equivalent. For DC power install a 1N4005 diode or equivalent.
Maglock
(control board)
1N4005 diode or equivalent.
Siemens S10K30 MOV
(Metal Oxide Varistor) or equivalent.
Solenoid Lock
-
+
(not provided)
1N4005 diode or equivalent.
-
+
(not provided)
MISCELLANEOUS WIRING
SINGLE BUTTON CONTROL (SBC) (2 Terminals)
Gate command sequence - Open, Stop, Close, Stop,...
Soft open (maintained switch does not override external safeties and does not reset alarm condition).
FIRE DEPARTMENT OPEN INPUT (2 Terminals)
Acts as hard open.
Maintained input overrides (ignores) external safeties (photoelectric sensor and edge), pauses Timer-to-Close momentary input logic as single button control and safeties remain active, re-enables Timer-to-Close.
ACCESSORY POWER 24 VDC, MAX 500 mA (4 Terminals)
• SWITCHED: Switched ON with gate motion (stays on 5 seconds after motion).
• UNSWITCHED: 24 Vdc voltage out to power accessories, always ON.
(main control board)
Single Button Control Station
SBC
Com
Fire Dept
Com
Fire Department
(main control board)
Accessory Power Switched
Com (-)
Acc Power +24 Vdc
Com (-)
Acc Power +24 Vdc
Accessory Power Unswitched
32
EXPANSION BOARD
To AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to the AUX relay contact terminal blocks.
EXPANSION BOARD OVERVIEW
1 QUICK CLOSE Switch:
OFF: No change to the gate's normal operation.
ON: When CLOSE EYES/Interrupt loop is deactivated it causes an opening or a stopped gate to close (ignores the Timer-to-Close).
2 AC FAIL Switch:
OPEN: Loss of AC power will cause the gate to open approximately
15 seconds after AC power fail and remain OPEN until AC power is restored (enabling the Timer-to-Close).
BATT: With loss of AC power, gate will remain in present position and operator is powered from batteries.
3 EXIT LOOP FAIL Switch:
• When set to OPEN, if the EXIT plug-in loop detector detects a fault, then the gate will open and remain open until fault is cleared. When set to CLOSE, then plug-in EXIT loop detector faults are ignored
(EXIT loop is faulted and inoperative).
the desired OPEN or CLOSE functionality.
7 1, 2, and 3 LEDs: LEDs indicating the status of the EYE/EDGE inputs.
Also used to check the firmware version of the expansion board:
1. Locate the 1, 2, and 3 LEDs on the expansion board.
2. Disconnect AC/DC power to the main control board for 15 seconds.
3. Connect power. The 1, 2, and 3 LEDs will flash in sequence until the main control board firmware revision is displayed. When the green POWER LED glows solid the LED 1 will flash the version number, then stop, then the LED 2 will flash the revision number
(for example: For version 5.1 when the green POWER LED is solid the LED 1 will flash 5 times, then stop, then the LED 2 will flash once).
8 MAIN BOARD Input: Input Connection for the main board connector.
OFF: When CLOSE EYES/Interrupt loop is activated it causes a closing gate to stop and reverse.
ON: When CLOSE EYES/Interrupt loop is activated it causes a closing gate to pause. Once the vehicle is clear the gate will continue to close.
5 AUX RELAY Switches: Set the AUX RELAY switches as needed to obtain the desired function as shown on the following page.
inputs.
10 Loop Detector Inputs: Inputs for the Plug-In Loop Detectors (Model
LOOPDETLM)
10
SHADOW INTERUPT EXIT
1 2 3 4
33
5
POWER
8
6
1
2
3
EYE
ONLY
EYE/
EDGE
EYE/
EDGE
COM
SBC
OPN
CLS
STP
COM
7
9
EXPANSION BOARD
AUXILIARY RELAYS
AUX RELAY 1
Normally - Open and Normally - Closed relay contacts to control external devices, function of relay contact activation determined by AUX Relay 1 option switch settings. (For connection of Class 2, low voltage (42 Vdc [34 Vac] max 5 Amps, power sources only.)
AUX RELAY 2
Normally - Open and Normally - Closed relay contacts to control external devices, function of relay contact activation determined by AUX Relay 2 option switch settings. (For connection of Class 2, low voltage (42 Vdc [34 Vac] max 5 Amps, power sources only.)
AUX RELAY
SETTING
1
SWITCH
SETTINGS
2 3
OFF OFF OFF
AUX RELAY 1 AUX RELAY 2
Off (no feature selected)
Open Limit Switch
Close Limit Switch
Gate Motion
Pre-Motion Delay
Power
Tamper
Cycle Quantity
Feedback*
Relay always off. Use this Aux Relay setting to conserve battery power.
OFF OFF ON
OFF ON OFF
Energizes at open limit. Use with SAMS (Sequenced Access Management System, jointly with barrier gate).
Energizes when not at close limit. For an additional audible or visual display, connect an external light (low voltage).
OFF ON ON Energizes when motor is on (gate in motion). For an additional audible or visual display, connect an external buzzer or light (low voltage).
ON OFF OFF Energizes 3 seconds before gate motion and remains energized during gate motion. The onboard alarm will sound. For an additional audible or visual display, connect an external buzzer or light (low voltage).
ON ON OFF Energizes when AC power or solar power is present. There is approximately a 10-12 second delay before relay cutoff, after AC shutdown.
Energizes 3 seconds before gate motion and remains energized during gate motion. For an additional audible or visual display, connect an external buzzer or light (low voltage).
Energizes when on battery power. There is approximately a 10-12 second delay before relay cutoff, after AC shutdown.
ON OFF ON Energizes if gate is manually tampered with by being pushed off of close limit. For an additional audible or visual display, connect an external buzzer or light (low voltage).
ON ON ON The 1, 2, and 3 LEDs will blink out the cycle count (cycle count is stored on the control board). See below.
Energizes if gate is manually tampered with by being pushed off of close limit. For an additional audible or visual display, connect an external buzzer or light (low voltage).
Not used.
CYCLE COUNT
* First, note the current Aux Relay switch positions. To determine the actual cycles that the gate operator has run (in thousands), set all three Aux
Relay switches to the ON setting for Aux Relay 1. The Expansion Board’s 1, 2, and 3 LEDs will blink out the cycle count, with 1 LED blinking 1000’s,
2 LED blinking 10,000’s, 3 LED blinking 100,000’s, and simultaneously all three LED’s blink 1,000,000’s (e.g. 1 LED blinks 3 times, 2 LED blinks 6 times, and 3 LED blinks once. Cycle count is 163,000.). Cycle count displayed is between 1,000 and 9,999,000 cycles. After servicing, set Aux Relay switches back to their appropriate positions. Cycle count cannot be reset or changed. If under 1,000 cycles the 1, 2, and 3 LEDs will turn on for 10 seconds, then turn off.
NOTE: The expansion board will flash the cycle count 3 times then all the LEDs will turn on solid for 10 seconds then turn off.
SHADOW INTERUPT EXIT
POWER
1
2
3
EYE
ONLY
EYE/
EDGE
EYE/
EDGE
COM
SBC
OPN
CLS
STP
COM
Aux Relay
AUX RELAY WIRING EXAMPLE
Class 2 Power
Source
(42 Vdc [34 Vac],
5 A max)
+ —
N.C.
COM
N.O.
Warning
Light
AUX RELAY 1 AUX RELAY 2
34
EXPANSION BOARD
WIRING ACCESSORIES TO THE EXPANSION BOARD
Refer to the chart below and the corresponding image for a description of the expansion board inputs.
A Entrapment Protection Device Inputs
(4 terminals total), Open or Close
Direction based on switch setting next to inputs
B Single Button Control, SBC (2 terminals)
EYES ONLY Input: Open or Close Direction Photoelectric Sensors
EYES/EDGE Input(s): Open or Close Direction Photoelectric Sensors, Infra-red detector wired or Edge
Sensor
C
D
F
G
H
Open Input (& common) (3-Button
Control Station, 4 terminals total)
Close Input (& common) (3-Button
Control Station, 4 terminals total)
E Stop Input (& common)
(3-PB station, 4 terminals total)
Exit Loop Input (2 terminals)
Shadow Loop Input (2 terminals)
Interrupt Loop Input (2 terminals)
Gate command sequence - Open, Stop, Close, Stop, ...
Soft Open ,Soft Close, Soft Stop (maintained switch does not override external safeties and does not reset alarm condition)
Open command - opens a closed gate.
Soft open (maintained switch does not override external safeties and does not reset alarm condition)
If maintained, pauses Timer-to-Close at OPEN limit.
Opens a closing gate and holds open an open gate.
Close command - closes an open gate.
Soft close (maintained switch does not override external safeties and does not reset alarm condition)
Stop command - stops a moving gate.
Hard stop (maintained switch overrides Open and Close commands and resets alarm condition)
If maintained, pauses Timer-to-Close at OPEN limit.
Overrides an Open or Close command.
Loop wire connection for plug-in loop detector when loop is inside secured area near gate.
Open command - opens a closed gate.
Soft open (maintained switch does not override external safeties and does not reset alarm condition)
If maintained, pauses Timer-to-Close at OPEN limit.
Opens a closing gate and holds open an open gate.
Loop wire connection for plug-in loop detector when loop is positioned under the gate.
- Holds open gate at open limit
- Disregarded during gate motion
- Pauses Timer-to-Close at Open Limit
Loop wire connection for plug-in loop detector when loop is along the side of the gate.
- Holds open gate at open limit
- Stops and reverses a closing gate
- Pauses Timer-to-Close at Open Limit
POWER
1
2
3
EYE
ONLY
EYE/
EDGE
EYE/
EDGE
COM
SBC
OPN
CLS
STP
COM
N. C.
D
E
B
C
A
Photoelectric Sensor
Photoelectric
Sensor or
Edge
Photoelectric
Sensor or
Edge
SHADOW INTERUPT EXIT
G
H
F
35
MAINTENANCE
IMPORTANT SAFETY INFORMATION
To reduce the risk of SEVERE INJURY or DEATH:
• READ AND FOLLOW ALL INSTRUCTIONS.
• ANY maintenance to the operator or in the area near the operator
MUST NOT be performed until disconnecting the electrical power (AC or solar and battery) and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service.
• Disconnect power at the fuse box BEFORE proceeding. Operator
MUST be properly grounded and connected in accordance with national and local electrical codes. NOTE: The operator should be on a separate fused line of adequate capacity.
• NEVER let children operate or play with gate controls. Keep the remote control away from children.
• ALWAYS keep people and objects away from the gate. NO ONE
SHOULD CROSS THE PATH OF THE MOVING GATE.
• The entrance is for vehicles ONLY. Pedestrians MUST use separate entrance.
• Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or reverse when an object activates the noncontact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of INJURY or DEATH.
• Use the manual disconnect release ONLY when the gate is not moving.
• KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual.
Have a qualified service person make repairs to gate hardware.
• ALL maintenance MUST be performed by a LiftMaster professional.
• Activate gate ONLY when it can be seen clearly, is properly adjusted and there are no obstructions to gate travel.
• To reduce the risk of FIRE or INJURY to persons use ONLY
LiftMaster part 29-NP712 for replacement batteries.
• SAVE THESE INSTRUCTIONS.
• ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment.
MAINTENANCE CHART
Disconnect all power (AC, solar, battery) to the operator before servicing. The operator's AC Power switch ONLY turns off AC power to the control board and DOES NOT turn off battery power. ALWAYS disconnect the batteries to service the operator.
DESCRIPTION TASK
Entrapment Protection Devices
Warning Signs
Manual Release
Gate
Accessories
Electrical
Mounting Hardware
Operator
Batteries
Check and test for proper operation
Make sure they are present
Check and test for proper operation
Inspect for wear or damage
Check all for proper operation
Inspect all wire connections
Check for tightness
Inspect for wear or damage
Replace
CHECK AT LEAST ONCE EVERY
MONTH
X
X
6 MONTHS 3 YEARS
X
X
X
X
X
X
X
NOTES:
• Severe or high cycle usage will require more frequent maintenance checks.
• It is suggested that while at the site voltage readings be taken at the operator. Using a digital voltmeter, verify that the incoming voltage to the operator is within ten percent of the operator’s rating.
BATTERIES
Batteries will degrade over time depending on temperature and usage.
The operator alarm will beep 3 times with a command if the battery is low. Batteries do not perform well in extremely cold temperatures. For best performance, the batteries should be replaced every 3 years. Use only LiftMaster part 29-NP712 for replacement batteries. The standard control box comes with two 7AH batteries.
36
Two 33AH (A12330SGLPK) may be used in place of the 7AH batteries for a Large Metal Control Box solar installation. A battery tray (model K10-
36183) and battery harness (model K94-37236) are required for 33AH applications.
The batteries contain lead and need to be disposed of properly.
TROUBLESHOOTING
To protect against fire and electrocution:
• DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator.
For continued protection against fire:
• Replace ONLY with fuse of same type and rating.
ERROR CODES
NOTE: When cycling or disconnecting power (ac/dc) to the control board, it is recommended that you unplug the J15 plug.
TO VIEW THE ERROR CODES
The error codes are shown on the error code display.
...then press and hold the
OPEN button until “Er” shows
...then press and hold the
CLOSE button...
Press and hold the
STOP button...
The operator will show the error sequence number followed by the error code number:
ERROR SEQUENCE NUMBER
The first number shown is the most recent error (example: "01" shown below). The display will show the sequence of errors that occurred starting with "01" and going up to error
"20".
A SECOND
LATER....
ERROR CODE NUMBER
The second number shown after the error sequence number is the error code itself (31-99, example" "31" shown below). Refer to the chart on the following page for an explanation of each error code.
ERROR CODE DISPLAY
OPEN, CLOSE, & STOP BUTTONS
TO SCROLL THROUGH THE SAVED ERROR CODES
TO EXIT ERROR CODE DISPLAY
Press and release the STOP button to exit. The error code display will also time out after two minutes of inactivity.
Press the OPEN button to cycle to the most recent errors ("01").
Press the CLOSE button to cycle to the oldest error (up to "20").
The operator will only keep track of up to 20 errors, then will start saving over the oldest errors as new errors occur.
TO RESET THE ERROR CODE HISTORY
1. Press and hold the STOP button for six seconds. The display will show "Er" then "CL" alternately for six seconds.
2. Release the STOP button. The error history has now been reset and the display will show "- -" until a new error occurs.
3. Press and release the STOP button to exit.
37
TROUBLESHOOTING
ERROR CODES continued...
Some errors are saved in the error code history and some are not. If an error is not saved it will briefly appear on the error code display as it occurs, then disappear.
Code Error Meaning
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
51
52
53
54
60
61
62
63
64
65
Solution
Control board has experienced an internal failure.
Disconnect all power, wait 15 seconds, then reconnect power (reboot).
If issue continues, replace control board.
Linear Drive Disengaged (Arm 1) Disengage then re-engage arm, check wiring and connections.
Linear Drive Disengaged (Arm 2)
Absolute Position Encoder Error, not getting position information from encoder
Max-Run-Time Exceeded Error
Disengage then re-engage arm, check wiring and connections.
Check the operator cable connections, then reprogram the limits.
Check for an obstruction, then reprogram the limits.
Product ID Error
Product ID Failure
Hard Stop Limit (Arm 1)
Hard Stop Limit (Arm 2)
Was the control board just replaced? If so, erase limits, enter limit setup mode and set limits. If not, disconnect all power, wait 15 seconds, then reconnect power before changing product ID harness.
Unplug product ID harness then plug back in. Disconnect all power, wait 15 seconds, then reconnect power before replacing product ID harness.
Limit may be set too tightly against a non-resilient hard stop (re-adjust limit). Operator may be at end of travel (re-adjust mounting).
Limit may be set too tightly against a non-resilient hard stop (re-adjust limit). Operator may be at end of travel (re-adjust mounting).
Battery overvoltage
Battery overcurrent
No battery at boot up
Loop Error - Failure or missing exit loop (SHORT or OPEN - LiftMaster Plug-in Loop Detector only)
Loop Error - Failure or missing shadow loop
(SHORT or OPEN - LiftMaster Plug-in Loop
Detector only)
Loop Error - Failure or missing interrupt loop
(SHORT or OPEN - LiftMaster Plug-in Loop
Detector only)
Wireless edge battery low
Pass-point not detected (Arm 1)
Pass-point not detected (Arm 2)
Brownout occurred
Wireless Second Operator Communication Error
Minimum number of monitored entrapment protection devices (one) not installed.
CLOSE EYE/INTERRUPT held more than 3 minutes
(main board)
CLOSE EDGE held more than 3 minutes (main board)
OPEN EYE/EDGE held more than 3 minutes (main board)
CLOSE EYE/INTERRUPT held more than 3 minutes
(expansion board)
CLOSE EYE/EDGE held more than 3 minutes
(expansion board)
Too much voltage on the battery. Check harness. Make sure you do
NOT have a 24V battery on a 12V system.
Possible short of the battery charge harness. Check harness. Make sure you do NOT have a 12V battery on a 24V system.
Check battery connections and installation. Replace batteries if depleted to less than 20V on a 24V system. Make sure you do NOT have a single 12V battery on a 24V system.
Check loop wiring throughout connection. May be a short in the loop, or an open connection in the loop.
Check loop wiring throughout connection. May be a short in the loop, or an open connection in the loop.
Check loop wiring throughout connection. May be a short in the loop, or an open connection in the loop.
Replace batteries in wireless edge.
Check yellow pass-point wiring. If limits are not accurate, reprogram.
Rarely, may be standard operation.
Check yellow pass-point wiring. If limits are not accurate, reprogram.
Rarely, may be standard operation.
AC/DC board supply dipped below allowable level. Review power supply and wiring. If rebooting, ensure enough time for discharge of power to force a fresh boot.
Check the second operator for power. If OFF, restore power and try to run the system. If powered, deactivate the wireless feature and then re-learn the second operator.
Review monitored entrapment protection device connections.
Check CLOSE EYE/INTERRUPT input on main board; check for alignment or obstruction.
Check CLOSE EDGE input on main board; check for alignment or obstruction.
Check OPEN EYE/EDGE input on main board; check for alignment or obstruction.
Check wired input on expansion board; check for alignment or obstruction.
Check wired input on expansion board; check for alignment or obstruction.
38
Saved
NO
YES
YES
YES
YES
YES
YES
NO
NO
YES
YES
YES
YES
YES
YES
YES
NO
NO
YES
YES
NO
YES
YES
YES
YES
YES
TROUBLESHOOTING
ERROR CODES continued...
Some errors are saved in the error code history and some are not. If an error is not saved it will briefly appear on the error code display as it occurs, then disappear.
Code Error Meaning
66
67
68
69
OPEN EYE/EDGE held more than 3 minutes
(expansion board)
Wireless edge triggered more than 3 minutes
Wireless edge loss of monitoring
Wireless edge triggered
70
71
72
73
74
75
80
81
82
83
CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC (main board)
CLOSE EDGE triggered, causing reversal, preventing close, or cancelling TTC (main board)
OPEN EYE/EDGE triggered, causing reversal or preventing opening (main board)
CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC
(expansion board)
CLOSE EYE/EDGE triggered, causing reversal and preventing close or cancelling TTC (expansion board)
OPEN EYE/EDGE triggered, causing reversal or preventing opening (expansion board)
Close input (EYE/EDGE) communication fault
(secondary control box)
Open input (EYE/EDGE) communication fault
(secondary control box)
Close input (EYE/EDGE) communication fault
(expansion board)
Open input (EYE/EDGE) communication fault
(expansion board)
Force reversal (Arm 1)
91
92
93
94
99
Force reversal (Arm 2)
RPM / STALL Reversal (Arm 1)
RPM / STALL Reversal (Arm 2)
Normal Operation
Solution
Check wired input on expansion board; check for alignment or obstruction.
Check wired input for wiring issue or obstruction.
Check wireless edge inputs.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check inputs and wiring.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring.
Check the connections between the main board and the secondary operator.
Check the connections between the main board and the secondary operator.
Check the connections between the main board and the expansion board.
Check the connections between the main board and the expansion board.
Check for obstruction. If no obstruction, check that the operator arm is engaged and free to move. Refer to Limit and Force Adjustment section, and Obstruction Test.
Check for obstruction. If no obstruction, check that the operator arm is engaged and free to move. Refer to Limit and Force Adjustment section, and Obstruction Test.
Check for obstruction. If no obstruction, check the operator cable wiring and that the operator arm is engaged and free to move. Replace the operator arm if necessary.
Check for obstruction. If no obstruction, check the operator cable wiring and that the operator arm is engaged and free to move. Replace the operator arm if necessary.
No action required
Saved
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
YES
39
TROUBLESHOOTING
CONTROL BOARD LEDS
INPUT
POWER
OFF
ON
STATUS LEDS
BATT
CHARGING
TIMER
GATE
MOVING
OFF
ON
OFF
ON
MEDIUM BLINK (1 blink per second)
FAST BLINK (2 blinks per second)
FASTEST BLINK (8 blinks per second)
OFF
ON
MEDIUM BLINK (1 blink per second)
FASTEST BLINK (8 blinks per second)
BATT LOW OFF
ON
ACC PWR
OVLD
BLINK (1 blink per second)
OFF
ON
OFF state
AC charger or Solar power available
Not charging
Three stage battery charging
The timer is disabled
The timer is enabled
The timer is running
The timer is paused
The timer is cancelled
The gate is stopped
The gate is opening or closing
Operator is in E1 (single entrapment)
The operator is in E2 (double entrapment)
No battery error
Battery low
Battery critically low
OFF state
Accessory overload protector opened
SBC INPUT
FIRE DEPT
INPUT
EXIT
SHADOW
CLOSE EYES/
INTERRUPT
CLOSE EDGE
OPEN EYES/
EDGE
LOCK
OFF
ON
BLINK
OFF
ON
BLINK
OFF
ON
BLINK
OFF
ON
BLINK
OFF
ON
BLINK
OFF
ON
BLINK
OFF
ON
BLINK
OFF
INPUT LEDS
Input inactive
Input active
Input active on other operator
Input inactive
Input active
Input active on other operator
Input inactive
Input active
Input active on other operator
Input inactive
Input active
Input active on other operator
Input inactive
Input active
Input active on other operator
Input inactive
Input active
Input active on other operator
Input inactive
Input active
Input active on other operator
Input inactive
ON
BLINK
Input active
Input active on other operator
STATUS LEDS INPUT LEDS
40
TROUBLESHOOTING
TROUBLESHOOTING CHART
SYMPTOM
Operator does not run and error code display not on.
Control board powers up, but motor does not run.
Arm moves, but cannot set correct limits.
POSSIBLE CAUSES a) No power to control board b) Open fuse c) If on battery power only, low or dead batteries d) Defective control board a) Reset button is stuck b) Stop button active or jumper not in place for stop circuit c) If on battery power only, low or dead batteries d) Open or Close input active e) Entrapment Protection Device active f) Vehicle loop detector or probe active g) Defective control board a) Arm does not extend or retract enough during travel b) Arm is interfering with mounting bracket c) Gate is too difficult to move
Gate does not fully open or fully close when setting limits.
a) Arm does not extend or retract enough during travel b) Arm is interfering with mounting bracket c) Gate is too difficult to move
Operator does not respond to a wired control/command
(example: Open,
Close, SBC, etc.)
Operator does not respond to a wireless control or transmitter a) Check Open and Close command input LEDs b) Stop button is active c) Reset button is stuck d) If on battery power only, low or dead batteries e) Entrapment Protection Device active f) Vehicle loop detector or vehicle probe active a) Check XMITTER LED when wireless control is active b) Stop button is active c) Reset button is stuck d) Poor radio reception
Gate stops during travel and reverses immediately.
a) Control (Open, Close) becoming active b) Vehicle loop detector active c) Low battery voltage
SOLUTIONS a) Check AC and battery power b) Check fuses c) Charge batteries by AC or solar power or replace batteries d) Replace defective control board a) Check Reset button b) Check Stop button is not “stuck on”, or verify that the stop button is a normally closed circuit, or put a jumper on the stop circuit. c) Charges batteries by AC or solar power or replace batteries d) Check all Open and Close inputs for a “stuck on” input e) Check all Entrapment Protection Device inputs for a “stuck on” sensor f) Check all vehicle detector inputs for a “stuck on” detector g) Replace defective control board a) Disengage the arm and ensure arm moves freely b) Examine the hinge point where the arm mounts to the gate post. Make sure that the arm housing does not hit or interfere with the gate post or mounting bracket. Correct as necessary.
c) Disconnect arm from gate and move gate manually. Gate must move easily and freely through its entire range, limit-to-limit. Repair gate as needed.
a) Disengage the arm and ensure arm moves freely b) Examine the hinge point where the arm mounts to the gate post. Make sure that the arm housing does not hit or interfere with the gate post or mounting bracket. Correct as necessary.
c) Remove arm from gate and move gate manually. Gate must move easily and freely through its entire range, limit-to-limit. Repair gate as needed.
a) Check all Open and Close inputs for a “stuck on” input b) Check Stop button is not “stuck on” c) Check Reset button d) Charges batteries by AC or solar power or replace batteries e) Check all Entrapment Protection Device inputs for a “stuck on” sensor f) Check all vehicle detector inputs for a “stuck on” detector a) Activate wireless control and check XMITTER LED is on. Re-learn wireless control/transmitter to control board. Replace wireless control as needed.
b) Check Stop button is not “stuck on” c) Check Reset button d) Check if similar wired control operates correctly. Check if wireless controls works properly when within a few feet of operator. Check operator’s antenna and antenna wire. Check other wireless controls or devices.
a) Check all Open and Close inputs for an active input b) Check all vehicle detector inputs for an active detector c) Battery voltage must be 23.0 Vdc or higher. Charge batteries by AC or solar power or replace batteries
Gate opens, but will not close with transmitter or
Timer-to-Close.
a) Open control active b) Vehicle loop detector active c) Loss of AC power with AC FAIL set to
OPEN d) Low battery with LOW BATT set to OPEN e Fire Dept input active f) Timer-to-Close not set g) Close Entrapment Protection Device active a) Check all Open inputs for an active input b) Check all vehicle detector inputs for an active detector c) Check AC power and AC Fail option setting d) Check if AC power is available. If no AC power, then running on batteries and battery voltage must be 23.0 Vdc or higher. Charge batteries by AC or solar power or replace batteries.
e) Check Fire Dept input f) Check Timer-to-Close (TTC) setting g) Check all Entrapment Protection Device inputs for an active sensor
41
TROUBLESHOOTING
TROUBLESHOOTING CHART continued...
SYMPTOM
Gate closes, but will not open.
POSSIBLE CAUSES a) Vehicle loop detector active b) Low battery with LOW BATT option set to CLOSE
Exit loop activation does not cause gate to open.
a) Exit vehicle detector setup incorrectly b) Defective Exit loop detector c) Low battery with LOW BATT option set to CLOSE
SOLUTIONS a) Check all vehicle detector inputs for an active detector b) Check if AC power is available. If no AC power, then running on batteries and battery voltage must be 23.0 Vdc or higher. Charge batteries by AC or solar power or replace batteries a) Review Exit loop detector settings. Adjust settings as needed.
b) Replace defective Exit loop detector.
c) Check if AC power is available. If no AC power, then running on batteries and battery voltage must be 23.0 Vdc or higher. Charge batteries by AC or solar power or replace batteries.
a) Review Interrupt loop detector settings. Adjust settings as needed.
b) Replace defective Interrupt loop detector.
Interrupt loop does not cause gate to stop and reverse.
Shadow loop does not keep gate at open limit.
a) Vehicle detector setup incorrectly b) Defective vehicle loop detector a) Vehicle detector setup incorrectly b) Defective vehicle loop detector
Obstruction in gate's path does not cause gate to stop and reverse a) Force adjustment needed
Photoelectric sensor does not stop or reverse gate.
a) Incorrect photoelectric sensor wiring b) Defective photoelectric sensor
Edge Sensor does not stop or reverse gate.
a) Incorrect edge sensor wiring b) Defective edge sensor a) Review Shadow loop detector settings. Adjust settings as needed.
b) Replace defective Shadow loop detector.
a) Refer to the Adjustment section to conduct the obstruction test and perform the proper force adjustment that is needed.
a) Check photoelectric sensor wiring. Retest that obstructing photoelectric sensor causes moving gate to stop, and may reverse direction.
b) Replace defective photoelectric sensor. Retest that obstructing photoelectric sensor causes moving gate to stop, and may reverse direction.
a) Check edge sensor wiring. Retest that activating edge sensor causes moving gate to stop and reverse direction.
b) Replace defective edge sensor. Retest that activating edge sensor causes moving gate to stop and reverse direction.
a) Check for cause of entrapment (obstruction) detection and correct. Press the reset button to shut off alarm and reset the operator.
Alarm sounds for 5 minutes or alarm sounds with a command.
Alarm beeps three times with a command.
a) Double entrapment occurred (two obstructions within a single activation) a) Low battery a) Check if AC power is available. If no AC power, then running on batteries and battery voltage must be 23.0 Vdc or higher. Charge batteries by AC or solar power or replace batteries
On dual-gate system, incorrect gate opens first or closes first.
Alarm beeps when running.
a) Incorrect Bipart switch setting a) Expansion board setting b) Constant pressure to open or close is given
Expansion board function not controlling gate.
a) Defective main board to expansion board wiring b) Incorrect input wiring to expansion board c) Defective expansion board or defective main board a) Change setting of both operator’s Bipart switch settings. One operator should have Bipart switch ON (operator that opens second) and the other operator should have Bipart switch OFF (operator that opens first) a) Pre-warning is set to "ON" b) Constant pressure to open or closed is given a) Check main board to expansion board wiring. If required, replace wire cable.
b) Check wiring to all inputs on expansion board. c) Replace defective expansion board or defective main board
42
TROUBLESHOOTING
TROUBLESHOOTING CHART continued...
SYMPTOM
Maglock not working correctly.
POSSIBLE CAUSES a) Maglock wired incorrectly
Solenoid lock not working correctly.
a) Solenoid wired incorrectly
SOLUTIONS a) Check that Maglock is wired to N.C. and COM terminals. Check that
Maglock has power (do not power maglock from control board accessory power terminals). If shorting lock’s NO and COM wires does not activate Maglock, then replace Maglock or Maglock wiring
(refer to Wiring Diagrams). a) Check that Solenoid is wired to N.O. and COM terminals. Check that
Solenoid has power (do not power solenoid from control board accessory power terminals). If shorting lock’s NC and COM wires does not activate Solenoid, then replace Solenoid lock or Solenoid wiring (refer to Wiring Diagrams).
a) Learn the limits Switched (SW) Accessory power remaining on.
Accessories connected to
Switch (SW) Accessory power not working correctly, turning off, or resetting.
a) Normal behavior
Accessories connected to
Accessory power not working correctly, turning off, or resetting.
a) In limit setup mode a) Accessory power protector active b) Defective control board
Quick Close not working correctly.
Anti-Tailgating not working correctly.
a) Anti-Tail setting incorrect b) Interrupt loop detector c) Defective Expansion board
AUX Relay not working correctly.
a) Quick Close setting incorrect b) Interrupt loop detector c) Defective Expansion board a) AUX Relay setting incorrect b) AUX Relay wiring incorrect c) Defective Expansion board
Solar operator not getting enough cycles per day a) Insufficient panel wattage b) Excessive accessory power draw c) Old batteries d) Solar panels are not getting enough sunlight
Solar operator, insufficient standby time a) Insufficient panel wattage b) Excessive accessory power draw c) Battery capacity too low a) Move accessory to accessory power "ON" a) Disconnect all accessory powered devices and measure accessory power voltage (should be 23 – 30 Vdc). If voltage is correct, connect accessories one at a time, measuring accessory voltage after every new connection.
b) Replace defective control board a) Check that Quick Close setting is ON b) Check operation of Interrupt Loop detector c) Replace defective Expansion board a) Check that Anti-Tail setting is ON b) Check operation of Interrupt Loop detector c) Replace defective Expansion board a) Check AUX Relay switches settings b) Check that wiring is connected to either N.O. and COM or to N.C. and COM.
c) Set AUX Relay to another setting and test. Replace defective expansion board.
a) Add more solar panels b) Reduce the accessory power draw by using LiftMaster low power accessories c) Replace batteries d) Relocate the solar panels away from obstructions (trees, buildings, etc.) a) Add more solar panels b) Reduce the accessory power draw by using LiftMaster low power accessories c) Use batteries with higher amp hour (AH) rating
43
APPENDIX
INSTALLATION TYPES
PULL-TO-OPEN
Post Install
Gate Hinge
Column Install
PUSH-TO-OPEN
Gate Hinge
Post Install
Gate Hinge
Heavy Steel
Plate for
Reinforcement
(Not provided)
Back Steel
Plates for
Reinforcement
(Not provided)
Gate Hinge
Top View
STEP 1
POSITION THE BRACKETS
If your application is Push-to-Open, refer to the illustrations below for the correct dimensions for step 1.
PUSH-TO-OPEN APPLICATION
( Top View)
8-1/2" (21.6 cm) Closed Gate
7-3/4" (19.7 cm)
44
NOTE: Weld Rebar
Behind Gate Hinges for Maximum
Strength.
Heavy Steel Plate for
Reinforcement (Not provided)
Top View
Heavy Steel
Plate for
Reinforcement
(Not provided)
Back Steel Bracket
(Reinforce if necessary)
Gate Hinge
Gate Hinge
PUSH-TO-OPEN APPLICATION
(
Top View)
Open Gate
35-1/2" (90.2 cm)
APPENDIX
STEP 8
SOLAR PANEL(S)
SOLAR PANELS ARE NOT PROVIDED. SEE ACCESSORIES.
33AH Battery Requirements:
• Large Metal Control Box for Solar Applications
(Model XLSOLARCONTDC)
7AH Battery Requirements:
• Standard Control Box for Solar Applications (Model LA500CONTDC)
• A minimum of two 10W solar panels in series
(Model SOLPNL10W12V)
• A maximum of six 10W solar panels (Model SOLPNL10W12V).
Configuration of three sets of two 10W paralleled panels put in series.
• A minimum of two 10W solar panels in series (Model
SOLPNL10W12V)
• A maximum of six 10W solar panels (Model SOLPNL10W12V).
Configuration of three sets of two 10W paralleled panels put in series.
• Two 7AH batteries (29-NP712)
• Two 33AH Batteries (Model A12330SGLPK)
• Solar Battery Harness (Model K94-37236)
• Solar Battery Harness (Model K94-37236)
• Battery Tray (Model K10-36183)
Disconnect the expansion board if it is not in use to improve performance. We recommend LiftMaster low power draw accessories to minimize power draw, refer to accessory page. Use the tables below to see performance trade-offs. NOTE: Input solar power is 24 Vdc at 60 watts maximum.
The solar panel(s) must be located in an open area clear of obstructions and shading for the entire day. The gate operator is not supported in northern climates where temperatures reach below -4˚F. This is due to cold weather and a reduced number of hours of sunlight during the winter months. Cycle rate may vary from solar chart for areas that reach below 32˚F. Solar panels should be cleaned on a regular basis for best performance to ensure proper operation.
SOLAR USAGE GUIDE
The LA500DC has best in class solar performance due to highly efficient electronics that draw very little power while the gate is not in use (standby).
Typical System Standby Battery Current Consumption (mA) System Configuration
2.7 mA
+1 mA
+2.4 mA
Main control board draw with no remote controls programmed
Low band radio receiver active (one or more wireless transmitters learned)
High band radio active (MyQ device programmed)
+11.1 mA
+3.8 mA
Expansion board
Per loop detector (up to 3 loop detectors can be plugged into the expansion board)
This low current draw drastically increases the number of days the operator can remain in standby. To determine your system’s performance, reference the above table and determine how many milliamps (mA) your system will draw from the batteries.
EXAMPLE 1: A system with only a main control board and one or more hand held remote controls programmed will draw 3.7 mA from the batteries while the system is in standby (2.7 mA + 1 mA = 3.7 mA).
EXAMPLE 2: A system with only a main control board, one or more hand held remote controls programmed, and 20 mA of external accessories connected to the main control board's accessory power output will draw 23.7 mA from the batteries while the system is in standby
(2.7 mA + 1 mA + 20 mA = 23.7 mA).
EXAMPLE 3: A system with a main control board, expansion board, two loop detectors, and one or more hand held remote controls programmed will draw 18 mA from the batteries while the system is in standby (2.7 mA + 11.1 mA + 3.8 mA * 2 +1 = 18.6 mA).
Operator performance with no sun or loss of AC power
BATTERY
CURRENT
DRAW (mA)
2.7
3.7
6.1
14.8
SYSTEM CONFIGURATION main control board only remote controls programmed remote controls and MyQ programmed remote controls and expansion board
18.6
26.2
remote controls, expansion board, and one loop detector remote controls, expansion board, and three loop detectors
30
40
60
100
200
300
500
All numbers are estimates. Actual results may vary.
DAYS OF STANDBY
7AH batteries
19
14
6
4
2
1
1
12
9
133
97
59
24
45
33AH batteries
84
60
26
16
8
5
3
52
39
180
180
180
105
SINGLE GATE CYCLES ON BATTERY
7AH batteries
500
500
500
500
500
500
500
500
500
500
500
500
500
33AH batteries
2781
2781
2781
2780
2780
2779
2779
2778
2776
2772
2761
2751
2731
DUAL GATE CYCLES ON BATTERY
7AH batteries
234
233
233
233
233
232
229
227
222
234
234
234
234
33AH batteries
1327
1327
1327
1327
1326
1326
1326
1325
1324
1323
1318
1313
1304
STEP 8 continued...
SOLAR PANEL(S)
SOLAR USAGE GUIDE
APPENDIX
2
3
1
SOLAR ZONES
NOT AVAILABLE
3
2
1
NOT AVAILABLE
1
BATTERY
CURRENT
DRAW (mA)
SOLAR GATE CYCLES PER DAY (SINGLE GATE)
ZONE 1
(6 Hrs sunlight/day)
7AH batteries 33AH batteries
ZONE 2
(4 Hrs Sunlight/day)
7AH batteries 33AH batteries
10W SOLAR PANEL
20W SOLAR PANEL
40W SOLAR PANEL
60W SOLAR PANEL
5
15
20
40
60
5
15
20
50
100
5
15
20
100
200
5
15
20
100
250
BATTERY
CURRENT
DRAW (mA)
7AH batteries
10W SOLAR PANEL
5
15
20
40
60
5
20W SOLAR PANEL
15
20
50
40W SOLAR PANEL
100
5
15
20
100
200
60W SOLAR PANEL
5
15
20
100
250
All numbers are estimates. Actual results may vary.
22
19
17
10 n/a
48
44
42
30
13
91
86
84
49
11
113
108
106
69
10
52
43
39
24
10
113
103
98
71
29
212
201
196
114
27
263
252
246
160
24
56
47
43
27
13
132
122
117
88
45
299
288
282
194
93
300
300
300
300
187
30
23
19 n/a n/a
67
59
54
30 n/a
128
118
113
41 n/a
159
149
143
67 n/a
SOLAR GATE CYCLES PER DAY (DUAL GATE)
33
25
21 n/a n/a
79
70
65
40 n/a
181
170
165
86 n/a
286
275
269
181
39
ZONE 1
(6 Hrs sunlight/day)
ZONE 2
(4 Hrs Sunlight/day)
33AH batteries
24
20
19
12 n/a
57
52
50
38
19
129
124
121
83
40
203
197
195
153
80
7AH batteries
13 n/a n/a n/a n/a
29 n/a
55
51
49
18 n/a
68
64
62
29 n/a
25
23
13
33AH batteries
14
11 n/a n/a n/a
34 n/a
78
73
71
37 n/a
123
118
115
78
17
30
28
17
46
ZONE 3
(2 Hrs Sunlight/day)
7AH batteries 33AH batteries
11 n/a n/a n/a n/a
27
20
16 n/a n/a
53
44
40 n/a n/a
66
57
53 n/a n/a
12 n/a n/a n/a n/a
32
24
21 n/a n/a
75
66
62 n/a n/a
120
111
106
35 n/a
ZONE 3
(2 Hrs Sunlight/day)
7AH batteries 33AH batteries n/a n/a n/a n/a n/a
12 n/a
23
19
17 n/a n/a
28
25
23 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a
14 n/a
32
29
27 n/a n/a
52
48
45
15 n/a
10 n/a n/a
APPENDIX
STEP 8 continued...
SOLAR PANEL(S)
The location of the panel(s) is critical to the success of the installation. In general, the panel(s) should be mounted using the provided angle bracket facing due south. Use a compass to determine direction. The solar panel(s) should be mounted in an area clear of all obstructions and shading from buildings and trees. If the panel(s) is not casting a shadow, the battery is not being charged.
TIPS:
• Tall trees or buildings that do not shade the solar panel(s) in the summer could shade the solar panel(s) during the winter months when the sun sits lower in the sky.
• The area around the solar panel(s) should be clear of shadows or obstructions to the sun for a 180° arc east to west.
• Wire runs should be kept as short as possible. The solar panel(s) can be located up to 100 feet (30.48 m) from the operator using #16 AWG wire in any direction, including elevating it.
• DO NOT install solar panel near potential shading or obstructions that will block the panel during any part of the day.
• To optimize the system for winter operation the angle can be increased an additional 15° (solar panel(s) sits more vertical).
Solar Panel
(Facing South)
Control Box
47
South
Sun’s Position
180°
South
APPENDIX
STEP 8 continued...
SOLAR PANEL(S)
INSTALL THE SOLAR PANEL
1. Position solar bracket on mounting surface. Mark and drill holes.
2. Insert two bolts into the track located on the back of the solar panel(s).
3. Slide bolts in track away from bolt hole and align both bolts.
4. Secure solar panel(s) to solar bracket using two washered nuts.
5. Secure solar panel(s) assembly to mounting surface using appropriate hardware.
Mounting Surface
Mounted Panel
Must Face South
Mounting Surface
WIRE THE SOLAR PANELS
1. Connect the red wire (+) from one solar panel to the black wire (-) of the other solar panel.
2. Connect the shorter red wire (+) from the J15 plug (new wire harness) labeled DC Power to the red wire on one solar panel.
3. Connect the shorter black wire (-) from the J15 plug (new wire harness) labeled DC Power to the black wire from the other solar panel.
+ -
BATT
- +
DC
POWER
J15
J15 Plug
(new wire harness Model
K94-37236)
–
Red
Wire (+)
Black Wire (-)
–
Red
Wire (+)
Solar Panels
–
Red
Wire (+)
Black
Wire (-)
+
Black
Wire (-)
+
Red
Wire (+)
Black
Wire (-)
+
48
APPENDIX
STEP 8 continued...
SOLAR PANEL(S)
CONNECT BATTERIES
1. Place the battery tray in the bottom right corner of the control box.
Ensure the wires are not pinched and routed to the side of the battery tray.
2. Place the batteries in the control box as shown.
3. Connect the longer red wire from the J15 plug (new solar wire harness) to the positive (+) terminal of one battery. Connect the longer black wire from the J15 plug (new wire harness) to the negative (-) terminal of the other battery.
4. Apply power by plugging the J15 plug (new solar wire harness) into the J15 input on the control board. NOTE: You may see a small spark when plugging the J15 plug into the board.
Large Metal Control Box for Solar Applications
(Model XLSOLARCONTDC)
J15 Input
+ -
BATT
- +
DC
POWER
J15
-
+ -
BATT
- +
DC
POWER
J15
+
-
+
Battery Tray
J15 Input
J15 Plug
(new wire harness Model K94-37236)
Red Wire (+)
Black Wire (-)
49
APPENDIX
LIMIT SETUP WITH A REMOTE CONTROL
To set the limits using a remote control, first you will need a 3-button remote control that has been programmed for OPEN, CLOSE, and STOP. Refer to the Programming section.
INITIAL LIMITS AND FORCE ADJUSTMENT
For dual gate applications the limits will have to be set for each operator. The gate MUST be attached to the operator before setting the limits and force.
Ensure the gate is closed.
1. Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode.
2. Press and hold the OPEN or CLOSE button on the remote control until the gate reaches the desired open position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control.
3. Once the gate is in the desired open position, press and release the
STOP button on the remote control.
4. Press and release the OPEN button on the remote control again to set the open limit.
5. Press and hold the CLOSE or OPEN button on the remote control until the gate reaches the desired close position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control.
6. Once the gate is in the desired close position, press and release the
STOP button on the remote control.
7. Press and release the CLOSE button on the remote control again to set the close limit.
8. Cycle the gate open and close. This automatically sets the force.
When limits are set properly the operator will automatically exit limit setting mode.
ADJUST THE LIMITS
If the limits have already been set the operator will exit the limit setting mode after resetting each limit.
Set the Close Limit Only
1. Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode.
2. Press and hold the CLOSE button on the remote control until the gate reaches the desired close position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control.
3. Once the gate is in the desired close position, press and release the
STOP button on the remote control.
4. Press and release the CLOSE button on the remote control again to set the close limit.
When the close limit is set properly the operator will automatically exit limit setting mode.
Set the Open Limit Only
1. Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode.
2. Press and hold the OPEN button on the remote control until the gate reaches the desired open position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control.
3. Once the gate is in the desired open position, press and release the
STOP button on the remote control.
4. Press and release the OPEN button on the remote control again to set the open limit.
When the open limit is set properly the operator will automatically exit limit setting mode.
3-Button Remote Control programmed for OPEN, CLOSE, and
STOP
SET OPEN SET CLOSE
PRESS &
RELEASE
50
APPENDIX
SAMS WIRING WITH RELAYS NOT ENERGIZED
The Sequenced Access Management System (SAMS) are programmable relays used to determine the order in which more than one control device operates across an opening. For example, where a swing gate and a barrier gate are both used, the swing gate may be set to open all the way before the barrier gate activates. An example of SAMS wiring is shown below.
Main Board
Exit Input
Barrier Arm Operator
C
Auxiliary
Command
NO
Access Device
SHADOW INTERUPT EXIT
Expansion Board
POWER
DEVICE INPUTS
1
EYE
ONLY
2
3
EYE/
EDGE
EYE/
EDGE
COM
SBC
OPN
CLS
STP
COM
Shadow Input
Dipswitch settings for AUX
Relay 1: 1-OFF, 2-OFF, 3-ON
AUX Relay 1
51
REPAIR PARTS
STANDARD CONTROL BOX
ITEM PART DESCRIPTION
1 K74-36798-1 Standard Plastic Control Box Only
2 K76-36296-1 Outlet
3 K75-36635 Control Board Bracket
GATE OPERATOR ARM
ITEM PART DESCRIPTION
11 LA500
12 KSWG-0623 Rear
14 Q230
15 Q232
16 K94-36591 with
NOT SHOWN
6 K94-36411 Piezo
7
8
K94-36408-1
K74-36596
Reset Switch with Product ID
Batteries (2) with jumper
10 29-NP712
NOT SHOWN
K77-36541
LA500CONTDC
Antenna
Standard Plastic Control Box (with control board)
LARGE METAL CONTROL BOX (XLM)
NOT SHOWN
K94-37236
K94-36274-1
K10-36183
APOW3
Solar 33AH Battery Harness
7AH Battery Harness
33AH Battery Tray
Transformer
1
11
2
4
9
5
3
14
10
6
7
13
8
52
12
15
14
16
STANDARD CONTROL BOX
To protect against fire and electrocution: installing or servicing operator.
For continued protection against fire:
• Replace ONLY with fuse of same type and rating.
WIRING DIAGRAM
Field Wiring
Edge
Edge
Blue Black
Field Wiring
BOARD
TO MAIN
CLOSE
OPEN
Black
Red
Purple
White
White
N.C.
COM N.O.
N.C.
COM N.O.
53
Black
Red
Input Power Connection
LARGE METAL CONTROL BOX
WIRING DIAGRAM
To protect against fire and electrocution:
• DISCONNECT power and battery BEFORE installing or servicing operator.
For continued protection against fire:
• Replace ONLY with fuse of same type and rating.
Field Wiring
Edge
Edge
Field Wiring
BOARD
TO MAIN
CLOSE
OPEN
Black
Red
Purple
White
White
N.C.
COM N.O.
N.C.
COM
N.O.
+ -
54 without transformer kit
Input Power Connection
Black
Red
Input Power Connection with transformer kit
ACCESSORIES
ENTRAPMENT PROTECTION DEVICES
PHOTOELECTRIC SENSORS (MONITORED,
NON-CONTACT)
The photoelectric sensors are designed to detect an obstacle in the path of the electronic beam and stop the operator. Includes mounting brackets.
Models CPS-UN4 and CPS-RPEN4GM (LiftMaster low power accessory)
MISCELLANEOUS
REMOTE ANTENNA EXTENSION KIT
The remote antenna extension kit allows the antenna to be remotely installed.
Model 86LM
WIRELESS ACCESS CONTROL RECEIVER
Access control receiver for up to 450 remote controls.
Model STAR450-315
VEHICLE DETECTION DEVICES
PHOTOELECTRIC SENSORS (NON-MONITORED,
NON-CONTACT)
The photoelectric sensors are designed to detect an obstacle in the path of the electronic beam and stop the operator. Includes mounting brackets.
Models AOMRON E3K-R10K4-NR (retro-reflective) and RETROAB 60-2728 (retro-reflective)
SENSING EDGE (2-WIRE, NON-MONITORED,
CONTACT)
Sensing edges can detect an obstacle upon contact and stop the operator.
Models G65MG0204, G65MG0205, G65MGR205, and G65MGS205
SENSING EDGE CHANNEL
Mounting channel for all MG020 type edges.
Model G65ME120C5
REMOTE CONTROLS
Chamberlain offers a variety of LiftMaster remote controls to satisfy your application needs. Single-button to 4-button, visor or key chain. The following remote controls are compatible with operators manufactured by
Chamberlain after 1993. Contact your authorized LiftMaster dealer for additional details and options.
3-BUTTON REMOTE CONTROL
The 3-button remote control can be programmed to control the operator. Includes visor clip.
Model 893MAX
3-BUTTON MINI-REMOTE CONTROL
The 3-button remote control can be programmed to control the operator. Includes key ring and fastening strip.
Model 890MAX
KEYLESS ENTRY
Enables homeowner to operate gate operator from outside by entering a 4-digit code on a specially designed keypad.
Model 877MAX
PLUG-IN LOOP DETECTOR
Low power. Conveniently plugs into existing control board.
Model LOOPDETLM
LOOP DETECTOR
Low power loop detectors mounted and wired separately inside control box. LiftMaster low power accessory.
Model LD7LP
VEHICLE SENSING PROBE
The vehicle sensing probe is buried in the ground and can detect a car as it approaches and will then open the gate.
Model CP3
SOLAR PANEL KIT - 10 WATT
This kit is to replace or add a solar panel to the operator application. Up to four solar panels can be connected to the operator. Requires a 33AH battery harness (see below).
Model SOLPNL10W12V (requires 2 minimum)
SOLENOID GATE LOCK
The automatic gate lock is a solenoid-driven lock that automatically unlocks when the gate is open and locks when the gate is closed. Can be mounted onto a gate or post. Can be released in case of emergency.
Model GC824-12 (12/24 Vac/dc)
MAGNETIC GATE LOCK
Outdoor magnetic lock, transformer, junction box, mounting plate and hardware. Not for use with
Solar Applications. Must be powered separately.
Model MG1300 (12/24 Vdc)
TRANSFORMER
Model APOW3
55
ACCESSORIES
BATTERIES
Gate access system batteries replace or upgrade the gate operator batteries. Two identical 12 Vdc batteries are required for each gate operator. Do not mix 7AH and 33AH batteries within a gate operator.
7AH BATTERIES
Standard 7 AMP-Hour Battery, 12 Vdc, to replace original batteries provided with operator. Reuse existing harnesses.
Model 29-NP712
33AH BATTERIES
Upgrade 33 AMP-Hour Battery, 12 Vdc. Ideal for solar applications and extended battery backup. For use with Large Metal Control Box ONLY.
Model A12330SGLPK
BATTERY TRAY
Required for 33AH applications.
Model K10-36183)
SOLAR BATTERY HARNESS
Required for 33AH applications.
Model K94-37236
56
WARRANTY
LIFTMASTER 2 YEAR LIMITED WARRANTY
The Chamberlain Group, Inc. (“Seller”) warrants to the first purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of 2 years from the date of purchase [and that the LA500DC is free from defect in materials and/or workmanship for a period of 2 years from the date of purchase]. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety.
If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-2806, toll free, before dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty repair. You will be advised of shipping instructions when you call. Please include a brief description of the problem and a dated proof-of-purchase receipt with any product returned for warranty repair. Products returned to Seller for warranty repair, which upon receipt by Seller are confirmed to be defective and covered by this limited warranty, will be repaired or replaced (at Seller’s sole option) at no cost to you and returned pre-paid. Defective parts will be repaired or replaced with new or factory-rebuilt parts at Seller’s sole option.
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE 2 YEAR LIMITED
WARRANTY PERIOD SET FORTH ABOVE [EXCEPT THE IMPLIED WARRANTIES WITH RESPECT TO THE LA500DC, WHICH IS
LIMITED IN DURATION TO THE 2 YEAR LIMITED WARRANTY PERIOD FOR THE LA500DC], AND NO IMPLIED WARRANTIES WILL
EXIST OR APPLY AFTER SUCH PERIOD. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED
BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO
PROVIDE REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS
PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, OR REPLACEMENT OF BATTERIES.
THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GATE OR GATE HARDWARE,
INCLUDING BUT NOT LIMITED TO THE GATE SPRINGS, GATE ROLLERS, GATE ALIGNMENT OR HINGES. THIS LIMITED
WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE. ANY SERVICE CALL THAT DETERMINES THE
PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU.
UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN
CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S LIABILITY FOR BREACH OF
WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED
HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS
PRODUCT.
Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
57
01-37069B
845 Larch Avenue
Elmhurst, Illinois 60126-1196 www.liftmaster.com
© 2014, The Chamberlain Group, Inc. – All Rights Reserved
Download
Key features
24Vdc Actuator Arm
Vehicular Swing Gate Applications
Single and Dual Swing Gate Configurations
Class I, II, III, & IV Usage Classification
Inherent Entrapment Protection
External Entrapment Protection (B1 & B2)
Expansion Board
Remote Control Capability
Frequently asked questions
These gate openers are designed for use with vehicular swing gates and are compatible with both single and dual gate configurations.
These openers are classified for use in Class I, II, III, and IV applications, covering residential, commercial, industrial, and restricted access vehicular gate scenarios.
These openers have built-in entrapment protection (Type A) and allow for the installation of additional external entrapment protection devices like photoelectric sensors and edge sensors (Type B1 & B2).