13s02 Flow
PricesSee
Start at Page
Coriolis Flow
Honeywell VersaFlow Coriolis Mass Flowmeters
Siemens SITRANS FC Coriolis Mass Flowmeters
Call
Call
64
70
Call
Call
Call
63
62
62
Call
Call
64
66
$55.00
$87.00
$366.00
$470.00
58
56
57
59
Call
61
Call
60
$3509.00
$1936.00
72
76
Call
65
Table of Viscosities of Common Substances
489
Differential Pressure and Multivariable Mass Flow
Honeywell SMV3000 Smart Mass Flowmeter
Pitot Tubes, Venturi Tubes, and Bluff Body Flowmeters
Orifice Plates and Orifice Flange Unions
Electromagnetic Flow
Honeywell VersaFlow Electromagnetic Flowmeters
Siemens SITRANS FM MAGFLO Electromagnetic Flowmeters
Mechanical Flow
GEMS Flowmeters and Switches
Kobold Flow Switches
Kobold Temperature Compensated Switches and Transmitters
RCM Direct Reading Flowmeters for Liquids, Air, or Gas
Thermal Mass Flow
Thermal Instrument Company Inline and Insertion Mass Flowmeters
Turbine Flow
Turbine Flowmeters for Gas and Liquid Service
Ultrasonics for Pipes and Open Channel Flow
Siemens F US Clamp-On Ultrasonic Flowmeters
Siemens SITRANS LUT440 Open Channel Flow Monitor
Vortex Flow
Honeywell VersaFlow Vortex Flowmeters
Reference Materials
Prices in this catalog are current at the publication date, and are subject to change without notice.
Due to manufacturer agreements, some products may not be available in all Lesman markets or
geographic areas.
Level Measurement
Instruments
Flow Measurement
Instruments
Pressure Transmitter
When you need mechanical flow instruments or the most precise non-contacting flow sensors and monitoring systems,
look to Lesman. Whatever the media or application, we can help you. When you’re not sure what instrument works best,
you can use our collection of application datasheets. Fill in your process information, fax it to Lesman, and we’ll put your
process through an engineering review with our manufacturer partners to come up with the exact instrumentation to
meet your needs.
Temperature Sensors
and Transmitters
55
Wireless Sensing and
Communications
TABLE OF
CONTENTS
Analytical Instruments
and Systems
FLOW MEASUREMENT INSTRUMENTS
FLOW:
MECHANICAL
V 01.2016
Level Measurement
Instruments
56
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Lesman Instrument Company
www.lesman.com
[email protected]
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Flowmeters, Switches and Visual Flow Indicators
PPS Polysulfone Paddle Flow Switch
Flow Measurement
Instruments
Switch: Hermetically sealed, magnetically actuated contact;
15VA max., 0.5A max., 250V max. capacity
Pressure: 145 PSI max.; 1.45 PSI max. drop
Adjustment Accuracy: ±20%
Switch Repeatability: ±3%
Maximum Temperature: 225° F
Material: NEMA 4 Polysulfone, stainless steel, ceramic magnet
Connections: Thread: 1” NPT; Electric: DIN 43650 plug
Pressure Transmitter
Pipe
Cutoff mark
Bore
“L” Approx.
1”
0.9”
1 1/4”
1.1”
1 1/2”
1.4”
2”
2.0”
2 1/2”
2.4”
3”
2.9”
Model Selection Guide
Switch Point (GPM Water)
Turn-OnTurn-off
9.5
5.0
9.5
5.0
14.5
9.5
19.0
9.5
24.0
14.5
28.5
19.0
Please allow 3-4 weeks for delivery.
Switch Type
Catalog Number
Normally Open, SPST, 15VA Max. PPS-3106
Normally Closed, SPST, 15VA Max. PPS-3105
Price
$124.00
124.00
BVO Series Flowmeter/Switch
for Water-Like Liquids
Accuracy: ±12% full scale; Repeatability: ±2% FS
Temperature: -10° to 212° F
Pressure: 145 PSIG max.
Flow Direction: Vertical, up
Switch Characteristics: N/O switch: 240 VAC/200
VDC max. , 1.5 Amp AC/1.0 Amp DC max., 50 VA,
50 W max. power, 4-8 mm float travel hysteresis.
SPDT switch: 240 VAC max. , 0.8 Amp AC max. , 30
VA max. power, 4-8 mm float travel hysteresis.
Model Selection Guide
Water
Fitting Pressure Loss
Body
Range
Size
@ Max. Flow
Brass 0.1 to 1.0 GPM 1/4” NPT
0.9 PSIG
Brass 1.0 to 5.0 GPM 1/2” NPT
1.1 PSIG
304 SS 0.1 to 1.0 GPM 1/4” NPT
0.9 PSIG
304 SS 1.0 to 5.0 GPM 1/2” NPT
1.1 PSIG
Optional SPDT Contact
Catalog
Number
BVO-6102
BVO-6116
BVO-6202
BVO-6216
Suffix -U
Price
$283.00
283.00
541.00
541.00
0.00
Insertion Paddle/Bellows Flow Switch for Liquids
Temperature Sensors
and Transmitters
• Position-Independent Installation
• Max. Pressure 160 PSI/450 PSI, Media
Temperatures to 250° F
Kobold FPS paddle bellows flow switches
are used wherever reliable control for minimum or maximum liquid flow is required.
The flowing medium exerts a force on the
paddle to actuate a micro switch. The instrument internals are separated from the
process by the bellows, making the FPS an
excellent choice for dirty media.
Wireless Sensing and
Communications
Looking for a compact flow switch for
non-viscous liquids?
Kobold’s KAL-D is a compact all-stainless calorimetric
thermal flow switch for use in small spaces and 1/4” NPT
fittings. It has a switching range from 0.15 to 6.6 feet per
second, works in pressures to 580 PSIG, and temperatures
to 176° F. KAL-D can even be used in Clean-in-Place applications with short-term temperature limits of 250° F.
KAL-D prices start at $357.00.
Analytical Instruments
and Systems
her
Searching for ot rs
cato
Kobold flow indi
ll
and switches? Ca
t
en
Lesman for curr
lit
bi y.
pricing and availa
Model Selection Guide
De-Actuating
GPM H2O
2.6–8.8
3.5–12.3
4.8–16.3
9.7–25.1
11.9–28.6
18.9–47.1
50.2–122.0
100.8–234.7
158.1–360.0
319.7–729.6
Please allow 3-4 weeks for delivery.
Actuating Pipe Catalog
Catalog
GPM H2O SizeNumber Price Number Price
4.4–9.3 1”
5.7–13.2 1.25”
7.5–17.6 1.5”
13.7–26.9 2”
17.6–30.2 2.5” FPS-5100 $277.00FPS-5200$368.00
27.3–50.2 3” (Brass)
(SS)
64.7–127.7 4”
125.1–244.8 5”
189.8–385.0 6”
374.7–759.5 8”
All Metal Paddle Flow Switch
Flow Speed: 12 ft/sec max., adjustable flow ranges
Contact: Reed switch SPST, N/O or N/C; 50VA, 50 watt,
250V, 1.5A max ratings
Pressure: 1450 PSI max.
Temperature: 230° F max.
Materials: Housing: NEMA 4, Glass-reinforced Polyamid;
Paddle, Leaf Spring, Beam: SS; Locking Plate, Screws: Brass;
O-Ring: Buna-N
Model Selection Guide
Brass paddle
flow switch,
5’ PVC cable
Switch ON
GPM H2O
0.9 - 1.3
1.3 - 2.1
3.0 - 4.0
3.2 - 5.0
4.9 - 8.5
9.2 - 15.0
Please allow 3-4 weeks for delivery.
Switch OFF
NPT
Catalog
GPM H2OConn. Number
0.6 - 1.2
1/4”
PSR-5105
1.0 - 2.0
1/2”
PSR-5115
2.2 - 3.0
3/4”
PSR-5120
2.4 - 4.5
1”
PSR-5125
3.8 - 7.8
1-1/4”
PSR-5132
7.9 - 14.3
1-1/2”
PSR-5140
Price
$87.00
87.00
87.00
99.00
118.00
130.00
Call for stainless steel bodies or larger pipe sizes.
u
▲
▲
▲
▲
▲
▼
▼
▼
▼
u
▼
▲
▼
▲
▼
u
▼
▲
▼
▼
▼
▲
▼
▼
u
▼
u
u
▼
▼
▼
Technology/Spec.
Coriolis Flowmeter
25:1 0.1-6” 0.15% 0.1%
0
L H
DP Mass Flowmeter
40:1
—
0.1% 0.1%
—
— H
DP Orifice Plate
4:1
>1”
1%
0.1% 10-30 H L
DP Pitot Tube
4:1 0.5-72” 0.75% 0.1%
10
L L
DP Venturi
10:1 0.5-72” 1%
0.1%
10
M L
DP Wedge
10:1 0.5-30” 3%
0.5%
12
H H
Fluidic Oscillatory
15:1 1-3”
1.5% 0.2%
10
L H
Magnetic Flowmeter
10:1 >0.1” 0.5% 0.2%
5
L M
Paddlewheel
3:10.1-1.5”2.5% 1%
0 H L
Positive Displacement 20:1 0.5-6”
1%
0.3%
0
H M
Rotameter
5:10.2-3”4-8% 2% 0 ML
Thermal Dispersion
100:1 0.2-72” 0.5% 0.2%
10
L H
Turbine Flowmeter
10:1 >0.25” 0.5% 0.1% 10-20 H H
50:1
V-Notch
300:1— 2-5% 2% 4H 0L
Vortex Flowmeter
H
>1”
1%
0.2% 20-30 M L
Weir
300:1— 2-5% 2% 4H 0L
Viscosity table for common
substances, page 489.
Temperature-Compensated Flow Switches and Transmitters
KAL-K Flow Switch/Trend Indicator for Liquids and Oils
Features
• No moveable parts
• Minimal pressure loss
• Simple media adjustment
• Temperature compensation
and switch point stability
• Unaffected by viscosity changes —
even for the smallest flow velocities!
• IP65 enclosure — insensitive to dirt
• Designed for minimal pipe intrusion
Specifications
Measuring Range: Water: 0.05 to 2 m/sec.; Oils: 0.1 to 4 m/sec. approx.
Operating Conditions: Pressure: 1450 PSIG max; Temperature: ‑10°–185° F
Switching: Adjustment: By potentiometer; Selectable output: NPN or PNP,
open collector; Current: 400 mA max.; Voltage: 24 VDC max.; Status indicator: Bicolored LED
Power: Supply voltage: 24 VDC ±10%; Current draw: 300 mA max.
Materials: Wetted parts: 304 or 316-Ti stainless steel; Housing: NEMA 4 Nylon
standard, NEMA 7 Al optional
Fittings: 1/2” or 3/4” NPT or 1-1/2” Tri-Clamp®.
Flow Trend Indicator: Eight red LEDs
Approximate Switch Point (GPM) per Pipe Diameter
NominalWaterNominalWaterNominalWater
IDRangeIDRangeIDRange
1/2”
0.3 – 5.0
2”
3.1 – 55
8”
50 – 900
3/4”
0.5 – 8.9
2-1/2”
4.4 – 80
10”
78 – 1400
1”
0.8 – 14
3”
7.9 – 140
12”
110 – 2000
1-1/4”
1.1 – 20
4”
12 – 220
16”
200 – 3600
1-1/2”
2.0 – 35
6”
28 – 500
20”
310 – 5600
Model Selection Guide
Description
Catalog Number Price
KAL-K Flow Switch for Liquids, 24 VDC Power
304 SS Wetted Parts, 1/2” NPT
KAL-4215
$366.00
316-Ti SS Wetted Parts, 1/2” NPT
KAL-4315
414.00
316-Ti SS Wetted Parts, 3/4” NPT
KAL-4320
424.00
316-Ti SS Wetted Parts, 3A Sanitary
KAL-4340-S
508.00
KAL-K Flow Switch, 110 VAC Power, SPST Dry Contact Output for Liquids
304 SS Wetted Parts, 1/2” NPT
KAL-4215-P03R
543.00
316-Ti SS Wetted Parts, 1/2” NPT
KAL-4315-P03R
591.00
316-Ti SS Wetted Parts, 3/4” NPT
KAL-4320-P03R
601.00
Options Fast Response (2.8-6 Sec.)
-F
0.00
Quick Disconnect Plug (24 VDC)
-M12
93.00
Pressure Transmitter
u
▲
u
u
▲
u
▼
▼
u
u
▼
▲
u
▼
u
▼
Relative Cost
Cryogenics
u
▲
▲
▲
▲
u
▼
▼
u
▲
▲
▲
▲
▼
▲
▼
Permanent PSI Drop
Steam
▲
u
▼
▼
▲
▼
▲
▲
▼
▼
▼
u
▼
u
▼
u
Upstream Pipe Diam.
Dirty Gas
▲
u
▲
u
▲
u
u
▲
u
u
u
u
u
u
u
u
Repeatability (%)
Clean Gas
▲
▲
u
▼
▲
u
▲
▲
u
▲
u
u
u
▼
u
▼
Accuracy (%FS)
Slurries
▲
▲
u
▼
▲
▲
u
▲
▼
▲
▼
u
▼
u
u
u
Sizes
Corrosives
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
Key
HHigh
MMedium
LLow
Turndown Ratio
Viscous Liquid
Technology Media Type
Coriolis Flowmeter
DP Mass Flowmeter
DP Orifice Plate
DP Pitot Tube
DP Wedge
DP Venturi
Fluidic Oscillatory
Magnetic Flowmeter
Paddlewheel
Positive Displacement
Rotameter
Thermal Dispersion
Turbine Flowmeter
V-Notch
Vortex Flowmeter
Weir
Dirty Liquid
Key
▲ Excellent: Recommended.
u Fair: Works, but depends
on the application.
▼ Poor: Do not use.
Clean Liquid
Need help figuring out which flow measurement instrumentation to use in your process? Start with the reference charts
below. Find your media type to help narrow down your choices. Then, take a look at the comparative specifications in the
chart at the right. Depending on your application, there may be more than one technology for you.
Temperature Sensors
and Transmitters
What’s the Right Flow Technology for Your Process?
Flow Measurement
Instruments
Level Measurement
Instruments
57
Wireless Sensing and
Communications
FLOW:
MECHANICAL
Analytical Instruments
and Systems
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
www.lesman.com
[email protected]
V 01.2016
Lesman Instrument Company
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
FLOW:
MECHANICAL
V 01.2016
Level Measurement
Instruments
58
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Lesman Instrument Company
www.lesman.com
[email protected]
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Flowmeters and Switches
RotorFlow® Flow Indicators
Gems Shuttle Switches Rise to the Occasion!
Flow Measurement
Instruments
Fluid, flowing through the switch housing, displaces
a spring-loaded, calibrated shuttle, which is metered
relative to a fixed orifice. When flow rate reaches the
calibrated setpoint, the shuttle moves up to the stem,
actuating the hermetically sealed reed switch. Flow
switches respond only to flow — not pressure!
RFI is Gems’RotorFlow® at its most basic form — a
bright orange rotor turning with fluid flow. Either
port can be used for incoming flow.
Body: Polypropylene, brass, or 316 stainless steel
Other wetted materials: Orange molded Nylon
rotor, ceramic rotor pin, polysulfone lens, glassreinforced polypropylene low flow adapter
Occasional Cleanout is a Snap!
Remove the bonnet easily without disturbing the
inline body.
Model Selection Guide
Pressure Transmitter
Flow Ranges (GPM) PressureOperatingCatalog
Port
Size
Low*
High
Max.
Temp. ° F Number
RotorFlow® RFI Flow Indicator, Polypropylene Body
0.25”
0.1 to 1.0
0.5 to 5.0
100 PSI
180° Max. 155420
0.50” 1.5 to 12.0 4.0 to 20.0 100 PSI
180° Max. 155480
RotorFlow® RFI Flow Indicator, Brass Body
0.25”
0.1 to 1.0
0.5 to 5.0
200 PSI
212° Max. 142541
0.50” 1.5 to 12.0 4.0 to 20.0 200 PSI
212° Max. 142542
0.75”
—
5.0 to 30.0 200 PSI
212° Max. 180392
RotorFlow® RFI Flow Indicator, 316 Stainless Steel Body
9/16” 0.1 to 1.0
0.5 to 5.0
200 PSI
212° Max. 174596
0.50” 1.5 to 12.0 4.0 to 20.0 200 PSI
212° Max. 173138
0.75”
—
5.0 to 30.0 200 PSI
212° Max. 181682
Price
$55.00
55.00
145.00
145.00
145.00
185.00
185.00
215.00
Low Cost Switches for
Threaded Plastic Piping
FS-200 flow switches provide accurate flow
detection with 1% repeatability. Bronze and
Teflon® construction delivers long life in water
and oil, and fluid temperatures to 300° F.
Setpoints are calibrated using water
at 70° F on increasing flow with unit in a
horizontal position (lead wires up).
Operating Pressure: 400 PSIG @ 100° F
Operating Temperature: -20° to 200° F
Switch: SPDT, 20 vA
Temperature Sensors
and Transmitters
Gems FS-500 offers low cost flow monitoring
with a variety of switch actuation points and low
pressure drop. All wetted parts are polypropylene
or stainless steel, making this switch ideal for a wide
range of chemical and temperature requirements.
The materials are also NSF or FDA approved for potable
water treatment applications including chlorinators, purifiers and heaters.
Wireless Sensing and
Communications
Wetted Materials: Housing, Bonnet, Shuttle,
Shuttle Cap: Polypropylene
O-Ring: Viton® or Buna N
Spring: 316 Stainless Steel
Retaining Clip: PH 15-7 Mo Stainless Steel
Maximum Operating Temp.: 0° to 212° F
Setpoint Accuracy: ±20%
Switch: SPST, N.O. Pilot Duty 20 VA, 120-240
VAC or VDC
Inlet/Outlet Ports: 3/4” Female NPT
Rugged Flow Switches Deliver
Accurate, Reliable Service
Model Selection Guide
Port Size
Model Selection Guide
FS-500 Flow Switch
Catalog
Setpoint Number Price
0.25
170231 $71.00
0.5
170232
71.00
1
170233
71.00
2
175117
71.00
2.5
170234
71.00
5
170235
71.00
1” NPT
1-1/4” NPT
General Purpose Switch for Plastic Piping
Analytical Instruments
and Systems
These Gems FS-400P switches have a noncorrosive,
clear PVC housing for broad chemical compatibility, and
are ideal for flow/no-flow detection.
1-1/2” NPT
Materials: PVC, Epoxy, and Buna-N
Switch: SPST, 20 VA, N.O. at no-flow
Model Selection Guide
Connect
Size
Actuation on
Increasing Flow
Pressure
Max.
Operating
Temp (° F)
1/2” NPT*
0.5 GPM ± 20%
120 PSIG
120°
* 3/4” IPS model with 1/2 NPT port installed.
Catalog
Number
Price
135805 $81.00
Flow
Setting
(GPM)
0.5
1
2
3
4
5
6
8
1
2
4
6
8
10
12
16
20
1.5
3
5
7.5
10
15
20
30
Bronze Body
Catalog
Number
Price
27051
$191.00
27052
191.00
27053
191.00
27054
191.00
27055
191.00
27056
191.00
27057
191.00
27058
191.00
27067
365.00
27068
365.00
27069
365.00
27070
365.00
27071
365.00
27072
365.00
27073
365.00
27074
365.00
27075
365.00
27085
447.00
27086
447.00
27087
447.00
27088
447.00
27089
447.00
27090
447.00
27081
447.00
27092
447.00
Stainless Steel Body
Catalog
Number
Price
27059
$569.00
27060
569.00
27061
569.00
27062
569.00
27063
569.00
27064
569.00
27065
569.00
27066
569.00
27076
838.00
27077
838.00
27078
838.00
27079
838.00
27080
838.00
27081
447.00
27082
838.00
27083
838.00
27084
838.00
27093
881.00
27094
881.00
27095
881.00
27096
881.00
27097
881.00
27098
881.00
27099
881.00
27100
881.00
Looking for other Gems flow switches or
indicators? Need a different material or port
size? Call Lesman!
Specifications
RCM Series 8000 Flo-Gage® is designed for larger
pipe sizes and mounts between adjoining flanges
(ANSI 150#, 300#, DIN PN10, PN16, JIS, AS). Install
the Flo-Gage just as you would install an orifice
plate, with flat gaskets and bolts (order separately).
Accuracy: ±3% full scale
Range: Flow rates to 500 GPM or 4000 SCFM;
Rangeability: 6:1
Mount: Horizontal (standard), flow to the right
Temperature: 212° F max. , 350° F max. optional
Pressure: 180 PSIG max., 400 PSIG max. optional
Construction: Diecast aluminum housing, glass
or polycarbonate crystal, bronze body, bronze
gear movement, Buna-N seals. Other materials
available on request
Options: High/Low alarm relays, 4-20 mA,
0-1000 Hz output, digital display for flow rate/
totalization
Specifications
Accuracy: ±3% full scale; Repeatability: 1% full scale
Range: Flow rates to 3000 GPM liquid or 20000 SCFM
gas; Rangeability: 6:1
Mount: Horizontal (standard), flow to the right
Operating Conditions: Temperature: 212° F max.,
350° F opt.; Pressure: 180 PSIG max., 400 PSIG opt.
Construction: Bronze body, movement, ABS housing
and crystal, Buna-N seal. Call for other materials
Options: Relay: High/Low alarms; Output: 4-20 mA,
0-1000 Hz frequency. Optional Digital Display.
Shown with optional 4-20 mA loop-powered
two-wire indicator. Displays 4-1/2 digits for flow
rate, 8 digits for total­ization. Includes scaled,
open collector output for re­mote totalizer, and
square root extraction for use with W3 solid- state
strain gauge. Call for pricing.
Model Selection Guide
Model Selection Guide for Liquids
Standard mounting is horizontal, (R) designates flow going to the right. For
other configurations, call Lesman. When ordering, please specify media, pressure,
and temperature.
Media
Type
NPT
Connection
0.5 - 6 GPH
1⁄2”
3.0 - 20 GPH
1⁄2”
5.0 - 60 GPH
1⁄2”
15 - 100 GPH
1⁄2”
0.5 - 4.0 GPM
1⁄4”
0.5 - 4.0 GPM
1⁄2”
0.5 - 6.0 GPM
1⁄2”
For
1.5 - 10 GPM
1⁄2”
Liquid
0.5 - 6.0 GPM
3⁄4”
1.5 - 10 GPM
3⁄4”
3.0 - 20 GPM
3⁄4”
3.0 - 20 GPM
1”
5.0 - 40 GPM
1”
5.0 - 40 GPM
1-1⁄2”
15 - 100 GPM
1-1⁄2”
15 - 100 GPM
2”
5.0 - 40 SCFH
1⁄2”
15 - 100 SCFH
1⁄2”
30 - 200 SCFH
1⁄2”
50 - 400 SCFH
1⁄2”
1.5 - 10 SCFM
1⁄4”
4.0 - 30 SCFM
1⁄4”
1.5 - 10 SCFM
1⁄2”
4.0 - 30 SCFM
1⁄2”
For Air
5.0 - 60 SCFM
1⁄2”
or Gas
5.0 - 60 SCFM
3⁄4”
15 - 100 SCFM
3⁄4”
30 - 200 SCFM
3⁄4”
30 - 200 SCFM
1”
50 - 600 SCFM
1-1⁄2”
50 - 600 SCFM
2”
150 - 1000 SCFM
2”
400 - 3000 SCFM
3”
Options: Add as suffix to catalog number
Calibrate for specific gravity other than water
Hi/Lo alarm setpoint relays (Req. 24 VDC power)
NEMA 4X Gasketed Meter Case
Flow Rate
Intrinsically safe switches
available. Call for pricing.
Catalog
Number
1⁄2-71-R-06-ES
1⁄2-71-R-20-ES
1⁄2-71-R-60-ES
1⁄2-71-R-100-ES
1⁄4-71-R-04
1⁄2-71-R-04
1⁄2-71-R-06
1⁄2-71-R-10
3⁄4-71-R-06
3⁄4-71-R-10
3⁄4-71-R-20
1-71-R-20
1-71-R-40
1.5-71-R-40
1.5-71-R-100
2-71-R-100
1⁄2-71-R-40-IES
1⁄2-71-R-100-IES
1⁄2-71-R-200-IES
1⁄2-71-R-400-IES
1⁄4-71-R-10-I
1⁄4-71-R-30-I
1⁄2-71-R-10-I
1⁄2-71-R-30-I
1⁄2-71-R-60-I
3⁄4-71-R-60-I
3⁄4-71-R-100-I
3⁄4-71-R-200-I
1-71-R-200-I
1.5-71-R-600-I
2-71-R-600-I
2-71-R-1000-I
3-71-R-3000-I
-C
-X
-D
Price
$ 580.00
580.00
580.00
580.00
470.00
470.00
470.00
470.00
530.00
530.00
530.00
555.00
555.00
630.00
630.00
730.00
665.00
665.00
665.00
665.00
555.00
555.00
555.00
555.00
555.00
615.00
615.00
615.00
640.00
715.00
815.00
815.00
1000.00
85.00
350.00
50.00
Media
Type
Range
Fittings
GPM Liquid
Flange Size
0.3 – 2.0
1⁄2”
0.4 – 3.0
1⁄2”
0.5 – 4.0
1⁄2”
0.5 – 6.0
1⁄2”
1.5 – 10
1⁄2”
0.5 – 6.0
3⁄4”
1.5 – 10
3⁄4”
2.0 – 15
3⁄4”
3.0 – 20
3⁄4”
2.0 – 15
1”
3.0 – 20
1”
5.0 – 40
1”
4.0 – 30
1-1⁄2”
5.0 – 40
1-1⁄2”
5.0 – 60
1-1⁄2”
15 – 100
1-1⁄2”
5.0 – 40
2”
5.0 – 60
2”
For
15 – 100
2”
Liquid
20 – 150
2”
30 – 200
2”
30 – 200
3”
40 – 300
3”
50 – 400
3”
60 – 500
3”
40 – 300
4”
50 – 400
4”
50 – 600
4”
100 – 800
4”
50 – 600
6”
100 – 800
6”
150 – 1000
6”
300 – 2000
6”
50 – 600
8”
150 – 1000
8”
300 – 2000
8”
400 – 3000
8”
Options: Add as suffix to catalog number
Hi/Low alarm setpoint relays (Req 24 VDC power)
4-20 mA loop-powered output
0-100 Hz output
For gas applications
Catalog
Number
1⁄2-81-R-02
1⁄2-81-R-03
1⁄2-81-R-04
1⁄2-81-R-06
1⁄2-81-R-10
3⁄4-81-R-06
3⁄4-81-R-10
3⁄4-81-R-15
3⁄4-81-R-20
1-81-R-15
1-81-R-20
1-81-R-40
1.5-81-R-30
1.5-81-R-40
1.5-81-R-60
1.5-81-R-100
2-81-R-40
2-81-R-60
2-81-R-100
2-81-R-150
2-81-R-200
3-81-R-200
3-81-R-300
3-81-R-400
3-81-R-500
4-81-R-300
4-81-R-400
4-81-R-600
4-81-R-800
6-81-R-600
6-81-R-800
6-81-R-1000
6-81-R-2000
8-81-R-600
8-81-R-1000
8-81-R-2000
8-81-R-3000
Price
$470.00
470.00
470.00
470.00
470.00
530.00
530.00
530.00
530.00
555.00
555.00
555.00
630.00
630.00
630.00
630.00
730.00
730.00
730.00
730.00
730.00
915.00
915.00
915.00
915.00
995.00
995.00
995.00
995.00
1200.00
1200.00
1200.00
1200.00
1650.00
1650.00
1650.00
1650.00
–X
–W
–Y
–I
350.00
600.00
600.00
85.00
Level Measurement
Instruments
Direct Reading Flowmeters
Flow Measurement
Instruments
59
Pressure Transmitter
FLOW:
MECHANICAL
Temperature Sensors
and Transmitters
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Wireless Sensing and
Communications
www.lesman.com
[email protected]
Analytical Instruments
and Systems
Lesman Instrument Company
V 01.2016
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
FLOW:
TURBINE
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
V 01.2016
Level Measurement
Instruments
60
Lesman Instrument Company
www.lesman.com
[email protected]
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Turbine Flowmeters for Gas and Liquid Service
Low Cost Industrial Flowmeters for Liquid Measurement
Flow Measurement
Instruments
Features
• Simple construction allows for rugged
and dependable service at low cost
• Off-the-shelf delivery; Companion
electronics available in 10 to 15 days
• Outstanding accuracy at low cost,
without compromise in design
Pressure Transmitter
For Gas Service
Specifications
Flowmeter Size: 1/4” to 3” diameter
Repeatable Flow Range: 0.25 to 800 GPM
Accuracy and Linearity: ±1.0% reading or better
Repeatability: ±0.1% reading or better
Temperature: ‑450° to 350° F with UB bearing; ‑450° to
450° F with C bearing
Signal Output: 10 MVRMS or greater with 10KΩ load at
minimum flow rate
Materials: 316 stainless steel; Rotor: 17.4 PH stainless steel;
Bearings: 440C stainless steel or hard carbon composite
For Liquid Service
Features
• Radio frequency (RF or MCP) pickup
coils provide wide rangeability
• Four blade angles available
(15°, 20°, 25°, and 30°) per
flowmeter size for optimum
performance
• Shielded, self-lubricating ball
bearings provide extended life
Temperature Sensors
and Transmitters
The design of these turbine gas meters minimizes drag effects, which
results in wide ranges and long-term accuracy. All meters are equipped
with special self-lubricating, long-life ball bearings and low-drag, magnetic, modulated carrier or pickups.
Gas turbine flowmeters are available with standard flanged, 37° flared,
NPT, or special end fittings. Hazardous and weatherproof coil enclosures
are available.
Specifications
Wireless Sensing and
Communications
Flowmeter Size: 1/2” x 1/4” to 12” diameter
Linear Range: 0.15 to 12,000 ACFM
Overrange: 150% of maximum flow (intermittently)
Linearity: ±1% reading
Repeatability: ±0.25% over usable range
Temperature: ‑450° to 350° F, to 400° F intermittent heat
Bearings: Ceramic hybrid ball bearings only
Materials: 316 SS. Other materials available for corrosive applications.
End Fittings: MS flared and flanged styles recommended
Features
• Threaded or flanged
process connections
• Outstanding accuracy
• Provides wide flow ranges
(10:1 to 100:1 turndown
ranges available)
• Wide variety of process
connections and
construction materials
• Operates over wide range
of temperatures and
pressures
Specifications
Size: 1/4” to 12” diameter
Linear Range: 0.35 to 12,000 GPM
Overrange: 150% of maximum flow (intermittently)
Linearity: ±0.5% reading (±0.25% typical) over tabulated linear flow range
Repeatability: ±0.1% (±0.05% typical) over tabulated repeatable range
Pressure Drop: 4 to 5 PSI at maximum linear flow rate at one CSTK
Turndown: 10:1 to 100:1
Temperature: ‑450° to 450° F; High temperature option to 850° F
End Fittings: NPT, MS flared, and flanged; Others available
Bearings: Ceramic hybrid ball bearings; Sleeve bearings in tungsten carbide;
Teflon and hard carbon composite available
Materials: 316 SS. Other materials available for corrosive applications.
Analytical Instruments
and Systems
Need help with turbine flowmeters?
Fill out the application datasheet from
Lesman.com/datasheets/ and fax it
back to Lesman.
Great for
ne mass flow
ha
et
m
applications!
Model 600-9 Inline Design
The Model 600-9 ther­mal mass flowmeter provides reliable, accurate
flow measurement with no obstructions to the actual flow path. It handles
liquids, slurries, gases, and homogeneous solids through a wide range
of flow rate, temperature, pressure, viscosity, abrasiveness, or chemical
compositions.
The 600-9’s sensor is built into the meter’s outer surface and is completely protected from adverse proc­ess conditions. The spool matches
the actual flow pipe in dimensions and construction material, and is
impervious to fluid, as is the rest of the line.
System electronics include the flow analyzer, temperature compensator, and signal conditioner to provide a linear output directly proportional
to mass flow. An optional output provides continuous temperature
measurement.
ebsite for
Call or visit our w ion.
at
more inform
Specifications
Accuracy: Better of ±1% full scale or 4% reading; Repeatability: Better than
0.2% reading; Linearity: 0.5%
Temperature Limits: ‑20° to 350° F; Calibrated Temperature Range: ±50° F
Pressure Limits: 0 to 1200 PSI (Max. pressure ratings depend on pipe size.)
Pressure Range: Liquids: Unlimited; Gases: 20 atmospheres
Response Time: Liquids: Less than 1/2 second; Gases: 1 to 2 seconds typical,
4 to 8 seconds worst case
Pressure Drop: Negligible, completely unobstructed flow path
Viscosity: Up to 5000 cps
Flow Rate: (Volumetric flow units for gases should be expressed in standard
or normal units.) Liquids: 0.003 grams/min minimum full scale; Gases: 2 SLPM
minimum full scale. Maximum determined by pipe capacity.
Flow Range: 10:1 (100:1, 1000:1, multiple ranges available)
Flow Element: Meets NEMA 4, 7, and 9 explosion-proof requirements. Electrical
connection: 1/2”; Construction: 316 SS standard (316 SS, 304 SS Hastelloy®,
Monel, Inconel®, tantalum, titanium, gold, platinum, nickel, Carpenter 20®,
glass); Connections: Flanged, Swagelok®, NPT, VCR, VCO, Tri-Clamp, concentric reducer, flared, sanitary, high pressure fittings, wafer, barbed, welded,
others; Coatings: Teflon®, tungsten, carbide, HMF®
Remote Flow Transmitter: Model 9200: Panel or wall mount; Model 926A:
NEMA 4 JIC type; Model 926B: NEMA 4, 7, and 9 explosion-proof. Others
available upon request
Outputs: Standard 4-20 mA DC isolated/1000Ω max. load (0-10V DC, 0‑5VDC,
10‑50 mA DC, pulse output)
Options: Digital flow indication, 8-digit LED totalizer, batch counter, hi/lo
alarm setpoints, bidirectional flow, temperature output, multiple ranges
Need help with thermal dispersion mass flowmeters?
Fill out the Thermal Instruments application datasheet from
www.Lesman.com/datasheets and fax it back to Lesman.
Model 62-9 Insertion Design
The Thermal Model 62-9 flow probe
is designed to measure the flow rates of
gases, liquids, or slurries in stacks, irregularly
shaped lines, and process ducts. Unlike
other probe flowmeters, the 62-9 has no
apertures that can become clogged with
par­ticles or distorted by heat. The sensing
element is located on the probe’s inside
leading edge and has no contact with the
flow stream.
The 62-9 can be made of pipe or tubing
using any metal compatible with the flow stream
of a given application. It can also be built with
extra length, so it can be inserted through a gate
valve and packing gland. This will allow easy
insertion and removal while the pipe is in use.
The thermal probe’s electrical connections
can be made either in a gasketed-type conduit
or an explosion-proof conduit. For applications
over 350° F, the sensors are made of platinum
embedded in a ceramic matrix, securely bonded
to the pipe’s inside diameter. An additional
temperature sensor can also be installed, as
well as independent circuitry to provide fluid
temperature readout signals.
Specifications
Flow Range: 10:1 (100:1, 1000:1, multiple ranges available)
Flow Limits: (Volumetric flow units for gases should be expressed in standard
or normal units.) Liquids: 0.02 FPS to 20 FPS FS; Gases: 40 SFPM to 15000
SFPM FS. Maximum determined by pipe capacity.
Accuracy: Better of ±0.5% full scale or 2% reading. Calibrated by weight or
volume (0.5% FS). Repeatability: Better than 0.2% reading; Linearity: 0.5%
Temperature Limits: ‑20° to 1100° F; Calibrated Temperature Range: ±50° F
Pressure Limits: 0 to 60000 depending on size PSI
Response Time: Liquids: Less than 1/2 second; Gases: 1 to 2 seconds typical,
4 to 8 seconds worst case
Viscosity: Up to 5000 cps
Flow Element: Meets NEMA 4, 7, and 9 explosion-proof standards. Construction: 316 SS standard; Connections: Flanged, Swagelok®, NPT sanitary
Tri-Clamp, hot tapping, retractable, saddle mount; Coatings: Teflon®, HMF®,
Nedox®
Remote Flow Transmitter: Model 9200: Panel mount or NEMA 4 box; Model
926A: NEMA 4 JIC; Model 926B: NEMA 4, 7, and 9 explosion- proof.
Pipe Size: 1” minimum
Outputs: Standard 4-20 mA DC isolated/1000Ω max. load (0-10V DC, 0‑5VDC,
10‑50 mA DC, pulse output)
Options: Digital flow indication, 8-digit LED totalizer, batch counter, hi/lo
alarm setpoints, bidirectional flow, temperature output, multiple ranges,
flow profile, multipoint, averaging
Level Measurement
Instruments
Thermal Dispersion Mass Flowmeters
Flow Measurement
Instruments
61
Pressure Transmitter
FLOW:
THERMAL
Temperature Sensors
and Transmitters
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Wireless Sensing and
Communications
www.lesman.com
[email protected]
Analytical Instruments
and Systems
Lesman Instrument Company
V 01.2016
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Level Measurement
Instruments
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
V 01.2016
FLOW
ELEMENTS
62
Lesman Instrument Company
www.lesman.com
[email protected]
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Orifice Plates, Flange Unions, and Pitot Tubes
Please allow 10 days for delivery.
Flow Measurement
Instruments
If you need your order faster, just let us know.
In most cases, we can arrange for overnight
or second-day shipping. Or, we’ll work with
you to arrange delivery by local messenger
service. Same-day shipping is available for a
small premium.
Paddle-Type Orifice Plates
Build a Paddle Type Orifice Plate Part Number
Pressure Transmitter
Pipe
Size
Flange
Rating
Full
Face
Flange?
Plate
Thickness
____
__
__
01
See
Chart
Below
See
Chart
Below
Yes=FF
No= Blank
1/8”
Plate
Material Bore Style
__
C
304SS=04 Concen316SS=16
tric
Weep
Hole?
_
Drain or
Vent=W
No=Blank
What bore size do you need? _________________________________________
Not sure what bore size you need? We can calculate it for you. ($35 flat fee.)
If you need a drain or vent, specify Pipe Schedule or ID: ____________________
Raised Face Weld Neck
Orifice Flange Unions
Temperature Sensors
and Transmitters
All raised face flange unions are made of A105 carbon steel and include
nuts, bolts, and 1/16” gasket.
Build a Raised Face Weld Neck Orifice Flange Part Number
Wireless Sensing and
Communications
Analytical Instruments
and Systems
Pipe
Size
Flange
Rating
Material
Grade
Face
Style
Flange
Style
Pipe
Schedule
Hardware
____
__
CS
R
WN
40
C
See
Chart
Below
300#=03
600#=06
A105
Carbon
Steel
Raised
Face
Weld
Neck
Schedule
40
Complete
with Nuts,
Bolts, and
Gaskets
Code
0300
0400
0500
0600
0800
1000
1200
Pipe Size
14”
16”
18”
20”
24”
30”
36”
Code
1400
1600
1800
2000
2400
3000
3600
Code
03
Flange
600#
Code
06
(No 150#)
Pipe Size and Flange Rating Options
(1) Select Your Pipe Size
Pipe Size
0.5”
0.75”
1”
1.25”
1.5”
2”
2.5”
Code
0050
0750
0100
0125
0150
0200
0250
Pipe Size
3”
4”
5”
6”
8”
10”
12”
Other Flow Elements Available
from Lesman
Pitot Tubes
Inline sensors for measuring flow in pipe
lines from 1/2”to 3”nominal size. Uses two
averaging probes of equal area to sense
differential pressure loss while providing
minimum permanent pressure loss.
Probe or insert-type sensors for measuring flow in pipelines from 3” to 24”, using
equal area double averaging pitot tubes
for low permanent pressure loss.
Venturi Flow Elements
Herschel Type
Classic style Venturi tube designed
in accordance with ASME or ISO standards and offers a constant degree
of accuracy and high repeatability.
Venturi-Nozzle Type
Design uses the classical ASME and ISO
standards for highest accuracy, predictability, and repeata­bility. Flow conditioning gen­erated by unique hydraulic shape
provides a stable signal in a wide range of flows.
Low-Loss Design (Short-Form)
Design provides proven field per­formance in a variety
of applications. Low installation cost due to short laying
length, reduced operating costs, and a wide range of sizes
and materials add up to the right choice for your needs.
Bluff Body Differential Pressure Flowmeters
The bluff body flowmeter is the only differential pressure flowmeter
that fully conditions the flow prior to
measurement. It’s ideal for lines with
limited straight piping. This flowmeter
provides repeatable accuracy up to
±0.5% flow rate, even under the most
difficult flow conditions, and over a wide
range of Reynolds numbers.
Because this meter can accurately
measure disturbed flow, it doesn’t require the upstream or downstream straight pipe runs of many other
flowmeters; so, it can fit where other flowmeters can’t because of
limited space or weight requirements..
Left: Precision flow tube, Right: Insertion weld-on saddle.
(2) Specify the Flange Rating
Flange
150#
Code
01
Flange
300#
Call, fax, or e-mail your completed part number to Lesman
for a quote on price and delivery. Prices are valid for two
weeks from the quote date.
Need help finding the flow element you need? Fill out the application datasheet from
www.Lesman.com/datasheets and send it to Lesman for engineering review.
www.lesman.com
[email protected]
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
MULTIVARIABLE
TRANSMITTER
63
Smart Multivariable Flowmeter for Gas and Steam
Looking for differential pressure smart
transmitters for your flow applications?
See pages 86 to 89.
SMV3000
Level Measurement
Instruments
Lesman Instrument Company
V 01.2016
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Ordering Instructions
Make one selection from each table section below. Check any restriction letters
or notes (E.g.: N3) to be sure the unit is available. A finished catalog number looks
like this: SMA110-E1A-00000-S2,MB,F1C3-XXXX
Model Selection Guide
Turndown Ratio: 150:1
Accuracy: Analog Mode: Greater of ±0.10% calibrated span or URV; Digital
Mode: Lesser of ±0.075% calibrated span or ±0.15% reading.
Temperature Measurement
Range (Pt100Ω RTD): -328° to 1562° F operating; 1.08° F accuracy
Adjustment Range: Limit to zero/span within range.
Accuracy (Reference): Analog Mode: Digital accuracy + Output D/A accuracy; Digital Mode: Digital accuracy; (Output D/A): ±0.025% of span
Thermocouple Burnout: User-selectable detection: ON = up- or downscale failsafe action, critical status message for any open lead.
View full specifications online at Lesman.com
Catalog AvailNumberability
Price
• • •
•••
•••
j j j
1C
24.00
85.00
22.00
211.00
• • •
0.00
• • •
0.00
b
1J
Restrictions
b Select only one option from this group.
j Available only on units with CTFE fill ( _ 2 _ in Fill Fluid).
t Available only with 1/2” NPT adapter flange (Options
S2, T2, or V2).
v Includes side vent drain at no added cost.
w Available only with 316SS process heads. Not available
with side vent/drain (SV).
96
See pagewell
y
e
for Hon 00
SCT30
smart n
tio
configurait.
lk
o
o
t
Add a three-valve manifold to your transmitter!
See page 345. For 100Ω RTDs, see page 98.
Temperature Sensors
and Transmitters
TG
MC
WP
0X
Wireless Sensing and
Communications
A _ _ • • •
0.00
E _ _ • • •
77.00
J _ _ v v 1608.00
L _ _ v
821.00
_ 1 _ • • •
0.00
_ 2 _ • • •
57.00
_ _ A • • •
0.00
_ _ H t t t
0.00
00000 •••
0.00
00
•••
0.00
ME
• • •
170.00
VT
• • •
0.00
MB
• • •
20.00
SB b • • •
75.00
FB
• • •
20.00
LP
• • •
68.00
Pressure Transmitter
SMA110 ↓ $2939.00
SMA125 ↓ 2873.00
SMG170 ↓2938.00
Analytical Instruments
and Systems
Description
Differential Pressure Range
Pressure Range
0”-1” / 25” H2O
0-100 PSIA
Features
0"-1" / 400" H2O
0-750 PSIA
• Single sensor measures absolute and differential pressure
this
0"-1"
400"ed
H2O
0-3000 PSIG
ti/ nu
scon
from one pipe intrusion
Honeywell has di sman
Process
Vent/DrainBarrier
r
fo
ll Le
Head
Valve, Plug Diaphragm
t. Plea
• Calculations for volumetric or mass flow
rate,
or se ca uclinear
prod
t,
emenSteel
ac
pl
re
Material
Carbon
316 SS
316L SS
s
it
square root output conformity for differential
pressure,
on
n
informatio
316
316 SS
316L SS
. SS
and engineering units display for PV, flow rates martLine SMV800
Hastelloy C Hastelloy C Hastelloy C
the S
• Improves efficiency in commissioning, start-up, and on
Monel
Monel
Monel
going maintenance through local and remote interface
Fill Fluid Silicone
CTFE
with SmartLine Configuration Toolkit and host system
Process 1/4" NPT
Condensed Specifications
Head
1/2" NPT with Adapter (1/4" NPT Head)
No Selection
Temperature: -40° to 200° F; Meter Body : -40° to 257° F
None
Pressure: 1” H2O Abs for 2 hrs @ 158° F min.; Overpressure: 3000 PSI
Analog Meter (0-100 Even, 0-10 Sq. Root.) Two-Wire Output: 4–20 mA or digital (DE protocol)
Viton Head Gaskets (1/2" Gaskets Special)
RFI Protection (Std.): Negligible effect (20–1000 MHz @ 30V/meter)
Mounting Bracket — Carbon Steel
Mounting Bracket — Stainless Steel
Materials: Process Interface: 316L SS, Hastelloy C-276, Monel, Tantalum
Flat Mounting Bracket — Carbon Steel
diaphragms; 316 SS, Carbon Steel, Monel, Hastelloy process heads;
Lightning Protection Teflon, Viton head gaskets; Carbon Steel, A286 SS (NACE) bolting; MountStainless Steel Customer Wired-On Tag
ing Bracket: Carbon Steel; Electronics Housing: Low Copper Aluminum
(4 Lines, 28 Char/Line, User-Supplied Info.)
Hazardous Conditions: Housing meets NEMA 4 (watertight) and NEMA
Multivariable
Transmitter Configuration
7 (explosion-proof ); FM, CSA, ATEX approval available.
Write Protection
Differential Pressure Measurement
Clean for Oxygen/Chlorine Service, Certificate
Approval Type
Location/Class
Upper Range Limit (URL): 400” H2O (1000 mbar)
Explosion Proof
Cl I, Div 1, Gr A-D
Turndown Ratio: ±400:1
Dust Ignition Proof Cl II, III, Div 1, Gr E-G
Minimum Span: 20” H2O square root; 1” H2O linear
Suitable for
Cl III, Div 1
Zero Elevation/Suppression: No limit (min. span) within ±100% URL.
Non-Incendive
Cl I, Div 2, Gr A-D
FM Intrinsically Safe
Cl I, II, III, Div 1, Gr A-G
Accuracy: Analog Mode: Greater of ±0.10% calibrated span or URV; Digital
Mode: Lesser of ±0.075% calibrated span or ±0.15% reading.
Explosion Proof
Cl I, Div 1, Gr B-D
Dust Ignition Proof Cl II, III, Div 1, Gr E-G
Absolute Pressure Measurement
Suitable for
Cl III, Div 1
Non-Incendive
Cl I, Div 2, Gr A-D
Upper Range Limit (URL): 750 PSIA; Minimum Span: 5 PSIA
Intrinsically Safe
Cl I, II, III, Div 1, Gr A-G
Flow Measurement
Instruments
Ranges
Differential Pressure:
±400” H2O
Absolute Pressure: 0 to 750 PSIA
Process Temperature:
-328° to 842° F
FLOWMETER
SYSTEMS
V 01.2016
Level Measurement
Instruments
64
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Lesman Instrument Company
www.lesman.com
[email protected]
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Honeywell VersaFlow — Flowmeters for Any Application
Flow Measurement
Instruments
Pressure Transmitter
Electromagnetic Flowmeter
Coriolis Mass Flowmeter
•
•
•
•
• Innovative twin measuring tube sensors with optimized flow
divider for minimal pressure loss
• For applications up to 266° F (130° C)
• Measures from 0.3 to 430,000 kg/h flow
• Pressure-resistant jacket to 1450 PSI (100 bar)
• Excellent zero stability
• Available with hygienic process connections for food and
pharmaceutical applications
• Rapid signal processing, even with product and temperature
changes or sudden changes in density
• Modular electronics concept and data redundancy – sensor
and plug-and-play electronics are easy to replace
• Viscous or shear-sensitive products
• Products requiring low flow velocities, products with entrained solids or gas, or products in homogeneous mixtures
• Flow and purity measurement, density, temperature, and
concentration measurement
•
•
•
Temperature Sensors
and Transmitters
•
•
•
•
•
Wireless Sensing and
Communications
•
Conductivity down to 1 uS/cm
Temperatures to 356° F (180° C)
Available sizes 0.1” to 80” (DN 2.5-3000)
Stainless steel flow tube spool with carbon steel or stainless
steel flanges
Standard liner materials: PTFE, PFA, ETFE, hard rubber, and
polyurethane
Electrodes available in 316 stainless steel, Hastelloy C, platinum, titanium, tantalum, carbon, PTFE, and Cermet
Signal converters available in wall mount, rack mount, compact, and field-ready housings
Signal converter offers local display, infrared interface, HART
communications, four isolated outputs
Diagnostics to standards better than requested by NAMUR
2650: 100% flow sensor and converter check, 100% process/
application check, 100% linearity/calibration check
Accuracy to ±0.15% measured value
Suitable for all conductive applications
Measures flow in any application, from clean liquids to slurries and pastes with high solids content
Abrasion-, chemical-, and vacuum-resistant
Analytical Instruments
and Systems
VersaFlow magnetic flowmeter is suitable for a variety of measuring
tasks and applications, including rapidly changing media, pH jumps, large
amounts of solids, or pulsating flow. It delivers significant cost savings
during planning, procurement, installation, and training.
VersaFlow is wired exactly like a traditional magmeter, but no earth
connection to the liquid is required. This reduces the high costs involved
with purchasing exotic metal grounding rings or electrodes.
A new virtual reference grounding eliminates the need for grounding
electrodes or rings, reducing installation costs and potential leak points.
It provides complete isolation with opto-couplers of the flow converter’s
input amplifier and coil power circuits. The measurement circuit “floats”
at liquid’s potential, sensing only the induced voltage caused by the
velocity of the conductive liquid flowing through the sensor.
A calibrated flow simulator is available for magmeters to troubleshoot
converter and other system indicators and controls. It replaces the flow
sensor in the system and simulates no-flow and up to five flow rates to
troubleshoot flow output issues.
Visit www.Lesman.com for complete specifications.
VersaFlow coriolis measures mass flow, density, volume, temperature,
mass, or volume concentration and solids content with a single device.
It’s the only Coriolis sensor for mass flow in its class with secondary
pressure containment standard. It offers a high degree of accuracy,
even for problematic applications. All meters consist of a sensor and a
converter. The converter is mounted integral to the sensor or remotely
via a field-mount kit, a wall-mount housing, or a 19” rack-mount module.
Condensed Specifications
Flow Rate: 0–240 to 0–15800 lbs/min, depending on sensor model
Accuracy: Liquid: ±0.15% actual measured flow rate; Gas: ±0.5% actual
measured flow rate
Density Measuring Range: 25-155 Lbs/Ft3 (400-2500 Kg/m3)
Temperature Measuring Range: -40° to 302° F (-40° to 150° C); Accuracy:
±1.8° F (1° C)
Materials: Sensors available in Stainless steel, Titanium, Hastelloy, or Tantalum,
aluminum or stainless steel housings
Approvals: FM, CSA, ATEX, 3A (depending on model selected)
Visit www.Lesman.com for complete specifications.
See our viscosity table for common substances, page 489.
www.lesman.com
[email protected]
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
FLOWMETER
SYSTEMS
65
VersaFlow Vortex for Monitoring
Steam Production and Transfer
Level Measurement
Instruments
Lesman Instrument Company
V 01.2016
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Condensed Specifications
Measuring Principle: Karman vortex street
Measured Value: Primary: Number of separated vortices; Secondary: Operating and standard volumetric flow or mass flow
Accuracy: Reynolds numbers (Re)≥20000: ±0.75% for liquids, Re≥20000: ±1%
for gases or vapors; 10000<Re<20000: ±2% for liquids, gases, or vapors;
Repeatability: ±0.1%; Stability: ±0.1% over 1 year
Process Medium Viscosity: <10 cP
Outputs: Current: 4-20 mA; Pulse: Pulse frequency 0.5 Hz; Communications:
HART® protocol
Approvals: FM: Class 1, Div 1; ATEX: II 2G EEx d ia [ia] IIC T6
Visit www.Lesman.com for complete specifications.
To select a Honeywell VersaFlow system for
your application, complete the datasheet from
www.Lesman.com/datasheets/ and send it to
Lesman for engineering review.
Size of Leak
1/8”
3/16”
1/4”
5/16”
3/8”
7/16”
1/2”
Steam Loss per
Month (Lbs)
52,500
117,000
210,00
325,000
470,000
637,000
835,000
Total Cost per
Month
$262.50
$585.00
$1,050.00
$1,625.00
$2,350.00
$3,185.00
$4,175.00
Annual
Cost
$3,150.00
$7,020.00
$12,600.00
$19,500.00
$28,200.00
$38,220.00
$50,100.00
One pound of 100 PSI steam contains about 1,200 BTUs. 1 MCF of
natural gas contains 1 million BTUs.
If the steam is produced at 85% efficiency, the input energy is 1411
BTUs per pound. (1200/0.85=1411) So, 1000 pounds of steam requires
1.4 million BTUs to produce it. The cost to produce 1000 pounds of
steam from natural gas is 1.4 x cost/MCF. So, when natural gas costs
$7/MCF, the cost of 1000 pounds of steam is $9.80.
Further, by using the vortex meter’s local display or the HART®
protocol, you can track temperature and see any extraordinary heat
loss from where you measured at the boiler. Heat loss means energy
costs, so tracking this variable can be critical.
Honeywell’s VersaFlow vortex meter is the only meter of its type
that offers integral temperature compensation standard, and integral
pressure compensation as an option. These features improve accuracy
and significantly reduce energy costs. VersaFlow can also be used for:
• Burner consumption measurement
• Controlling compressor capacity, consumption measurement in
compressed air networks
• SIP and CIP processes in the food, beverage, and pharmaceutical
industries
• Measuring industrial gases (natural gas, oxygen, nitrogen, hydrogen, and argon)
• Conductive and non-conductive liquids
Pressure Transmitter
Temperature Sensors
and Transmitters
For superheated and saturated steam measurement, steam boiler
monitoring, compressor output monitoring, measuring consumption in
compressed air systems, measuring consumption of industrial gases, SIP
and CIP processes in the food, beverage, and pharmaceutical industries
VersaFlow 100 is the only vortex flowmeter with integrated pressure
and temperature compensation in two-wire technology, providing
maximum performance at the lowest installed cost. VersaFlow provides
reliable measurement of operating, standard volumetric, and mass flow
of conductive and non-conductive liquids, gases, and vapors, even with
fluctuating pressures and temperatures.
Cost of steam leaks, given 100 PSI steam flow, at $5.00 per 1000 pounds.
Wireless Sensing and
Communications
• Works with conductive or non-conductive liquids, industrial
compressed gases
• Sensors with 0.5” to 12” flanges or 0.5” to 4” sandwich sizes
• Two-wire device with integrated pressure and temperature
compensation, plus compensation for saturated steam
• Non-wearing, fully welded stainless steel construction with
high corrosion, pressure, and temperature resistance
• Optimal process reliability: Intelligent stable readings, free of
external signal processing
• Maintenance-free sensor design
• Current, pulse, and HART communications outputs
Analytical Instruments
and Systems
Vortex Flowmeter
There are two costs associated with the production of steam. The
first is the gas feed to the boiler. The other is in monitoring the efficiency of the lines transporting the steam.
The major concern, once a line is designed, is the integrity of the
pipeline and how much steam is being lost to leakage.
By placing a vortex meter at the discharge of the boiler and taking advantage of the integral temperature measurement, you can
accurately measure the generated steam. If you have a flow meter
on the gas feed line, you can monitor boiler efficiency by comparing
gas use to pounds of steam produced.
Then, by placing another vortex meter at a designated spot further
downstream of the boiler, you can make the measurement again
and compare the flow rate of the steam to what’s coming off the
boiler. Any reduction in flow not accounted for by any usage points
in between can be attributed to leakage.
As you can see in the table, even a small leak can cost thousands
of dollars per year, not including the additional cost it takes to manufacture more steam to compensate for the loss. Left unchecked, a
1/2” leak can cost upwards of $50,000 per year.
Flow Measurement
Instruments
Cost of a steam leak
MAGNETIC
FLOWMETERS
V 01.2016
Level Measurement
Instruments
66
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Lesman Instrument Company
www.lesman.com
[email protected]
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
SITRANS FM MAGFLO Electromagnetic Flowmeters
Need FM Class I, Div 1 meters?
MAGFLO models are available for harsh
environments. Call Lesman for help.
Flow Measurement
Instruments
Pressure Transmitter
MAGFLO flowmeters make it easier for you to manage flow. Whether
it’s installation, managing operations, or verifying continuous accuracy,
our customers rely on Siemens MAGFLO to improve their processes.
Greater Flexibility and Expandability
• One transmitter/converter electronics box fits all sensor tubes
• Choice of integral mount, remote pipe or wall mount, explosion-proof,
or 19” rack mount electronics styles available
• Ready for your plant data network! Universal communications slot on
each converter
• Communication modules for HART®, Modbus RTU, Profibus PA/DP.
Add-on modules allow upgrades without buying a new flowmeter
Temperature Sensors
and Transmitters
Easier to Operate
Wireless Sensing and
Communications
• Mag 5100W doesn’t require grounding rings
• Robust construction and materials: PTFE, PFA, Ceramic, and NOVALAK
liners; AISI 316 Ti stainless steel, Hastelloy C, Titanium, Tantalum, and
Platinum electrodes
• Only Siemens offers NOVALAK, a revolutionary liner material with a
smooth, hard, non-porous finish that provides the highest level of
protection against corrosion, abrasion, high pressure and temperature,
and vacuum conditions. It has the chemical resistance you expect
from PTFE with the mechanical strength and stability of steel.
• Uniform user interface for all MAGFLO products
Easier to Commission
• Pushbuttons on transmitter electronics make setup easy for technicians and contractors
• SensorPROM holds identity of each flowmeter: Calibration data,
magnetic properties, user setup, and programming.
• SensorPROM module enables instant measurement at power-up
Easier to Service
Analytical Instruments
and Systems
• Transmitter replacement requires no programming
• SensorPROM automatically updates all settings after initialization
Flexible Transmitter Electronics
Choose between Mag 5000 (±0.5% accuracy) and Mag 6000 (±0.25%
accuracy) for high performance, easy operation, and reduced maintenance. Mag 5000 is a robust solution for all-around applications. Mag
6000 is for the more demanding applications where higher accuracy
and greater functionality are required.
The Mag 6000i (Industry) transmitter is designed for the special demands in the process industry. The robust, full-metal housing provides
superb protection, even in the harshest industrial environments. Full
input and output functionality is provided, even in the ATEX EEx d version.
Individual calibration and fingerprint (magnetic property) data are pre-programmed
at the factory and stored in the MAGFLO’s
SensorPROM module. Setup data is added
during configuration. This unique combination ensures a cost-effective, easy, and errorfree installation.
Plug and play communication modules
make your MAGFLO compatible with your plant network protocol.
Changing communications standards or moving the MAGFLO to a different network? Just swap out the communications module. No need
to buy a new magmeter.
Sensor Tube Designs for Every Industry
Mag 5100W: A sensor for all water and wastewater
applications. With its coned design, increased low-flow
accuracy is achieved, making it especially useful for leak
detection. It can be made suitable for direct burial and
constant flooding. Mag 5100W complies with drinking
water and custody transfer approvals.
Mag 1100: The flangeless wafer design that meets all
flange standards. The Mag 1100 is used in all industries
where the corrosion-resistant stainless steel housing and
highly resistant liner and electrodes fit even the most
extreme process media. Mag 1100s are available with FM
and ATEX approvals for installations in hazardous areas.
Its obstruction-free performance minimizes the risk of
deposits. And, it’s unaffected by the suspended solids,
viscosity, and temperatures typically found in pharmaceutical processes. The Mag 1100 is suitable for CIP and SIP cleaning,
and withstands the high pressures of hose-down.
Mag 1100 Food: Specially designed for the food and
beverage industry, Mag 1100F offers unique and flexible
process connections. Mag 1100F was the first to pass
EHEDG hygienic test and meets all sanitary standards. Its
performance is unaffected by suspended solids, viscosity,
and temperature changes.
The Mag 1100F features an AISI 316 stainless steel
enclosure with an IP67/NEMA 4X rating that is upgradable to IP68/NEMA 6P. It’s delivered with your choice of flange adapter,
with metal-to-metal design, and no grounding connection required.
Advanced Diagnostics of Application and Metering
• Identification in clear text and error log
• Error categories: Function, warning, permanent, and fatal
• Transmitter self-check including outputs and accuracy
• Sensor check function
•Overflow
• Empty pipe, partial filling, low conductivity, electrode fouling
• System verification with MAGFLO Verificator
Siemens has
Tri‑Clover and
Tri‑Clamp adapters
in stock, ready for
quick assembly and
shipment!
2
Plug and Play communication modules and swappable SensorPROM
memory module make replacing electronics quick and painless!
Mag 3100: This flexible and comprehensive sensor
program offers a wide range of sizes, to fit a wide variety
of general industry applications. Liners and measuring
electrodes capable of withstanding the most extreme
processes are available. All welded construction provides
a ruggedness that suits the toughest environments.
Mag 3100P: Designed to meet the most common specifications in the
chemical and process industries. It features fully welded construction for
ruggedness, and PTFE or PFA liners and Hastelloy electrodes for flexibility.
Mag 8000W: These battery-powered units give you the flexibility to
install a reliable water meter almost anywhere, without
sacrificing accuracy or performance. It’s optimized for
leakage detection and accurate billing.
The Mag 8000W features a datalogger with selectable
log interval up to 26 months, an infrared (IrDA) port for
on-site downloads, power management with selectable
battery alarm levels, a self-check feature with automated
data backup, and three totalizers, one with user reset.
Transmag 2: For Heavy-Duty Applications
Thanks to its pulsed AC system, the Transmag 2 is
capable of measuring where conventional DC field
technology fails, including applications with high concentrations of pulp stock, heavy slurries, or slurries with
magnetic particles.
Magnetic particles in the media boost the magnetic field in the flowmeter and cause bad readings. Transmag 2 overcomes this issue with
a second compensating coil circuit. The alternating field technology
generates a much stronger magnetic field within the sensor, to measure
more reliability and with greater precision — even when the media has
a high concentration of solids.
There’s a solution to every abrasive media application,
and the choice of construction material is crucial to protect the flowmeter. Besides inlet protection rings, Siemens
offers a broad range of liner and electrode materials —
like the soft LINATEX rubber and NOVALAK liner, which
have proven themselves in these harsh environments.
Need help finding the right magmeter?
Download the application datasheet from
www.Lesman.com/datasheets/ and send it to Lesman for
engineering review.
In-Situ Verification
Call for
Verificator
Service!
Using the MAGFLO Verificator, Siemens offers in-situ verification for documenting continuous accuracy for critical
process applications — especially crucial
when your application is required to
meet ISO 9001, ISO 4001 or other quality
management programs.
Through in-depth analysis, Siemens
has identified the parameters that influence the accuracy of a flowmeter operating in the real world. These parameters
are checked using a patented verification
technique for MAGFLO flowmeters.
In-situ verification requires no interruption of flow, no opening of pipes,
and no disconnection of cabling. The Verificator can run a full installation
test of the transmitter, sensor, and cabling — all in less than 15 minutes!
Transmitter Test: The transmitter test is a flow simulation test that
checks the whole electronic system from signal input to output. Using
the magnetic field energy, the Verificator simulates a flow signal to the
transmitter input. By measuring transmitter output, the Verificator calculates its accuracy against factory-defined values.
Flowmeter Insulation Test: This“cross-talk”test of the entire flowmeter
ensures that the sensor flow signal is unaffected by external influences. In this test,
the Verificator generates a high voltage
disturbance within the coil circuit, and
then looks for any cross-talk induced in the
flow signal circuit. By generating dynamic
disturbances close to the flow signal, the
flowmeter is tested for noise immunity to a maximum level.
Sensor Magnetism Test: This “boost” test of the magnetic field coil
ensures that the electromagnetic signal meets the original settings.
In the boost test, the Verificator changes the magnetic field pattern
and uses high voltage to get quick stable magnetic conditions. Then, it
compares the current sensor magnetism
to the factory “fingerprint” determined
during initial calibration, and stored in
SensorPROM.
An authorized, signed certificate documents the verification, and includes test
results with pass/fail approval, installation specifications, flowmeter specification and configuration, and Verificator
specification with calibration date (to ensure traceability to national and
international standards.)
Level Measurement
Instruments
Flow Measurement
Instruments
(2) SensorPROM
Memory Module
g rings.
• Mag 5100W doesn’t need groundin
so one universal spare covs,
tube
or
sens
all
fits
• One transmitter
ers all applications.
the keypad — contractors
• Easy transmitter configuration with
!
them
love
and technicians
cation service from Siemens,
• Owners can schedule on-site verifi
FLO Verificator unit.
a
or do their own verification with MAG
a quick swap-out.
er
serv
• SensorPROM makes replacement
, it’s easy to get data
ules
mod
on
• With the universal communicati
ork.
onto the plant netw
rd of reliability, with calibration
• They can produce a traceable reco
data and verification test results.
Pressure Transmitter
67
MAGFLO?
Why Do So Many Engineers Choose
(1) Universal
Signal Modules for
Communication
1
MAGNETIC
FLOWMETERS
Temperature Sensors
and Transmitters
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Wireless Sensing and
Communications
www.lesman.com
[email protected]
Analytical Instruments
and Systems
Lesman Instrument Company
V 01.2016
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
MAGNETIC
FLOWMETERS
V 01.2016
Level Measurement
Instruments
68
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Lesman Instrument Company
www.lesman.com
[email protected]
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
SITRANS FM MAGFLO Electromagnetic Flowmeters
Call for
Verificator
service
Flow Measurement
Instruments
Integral Mount
Mag 5000/Mag 6000
Rack/Panel Mount
Mag 5000/Mag 6000
Remote Mount
Mag 6000i (Ex d)
Pressure Transmitter
MAGFLO Transmitter Electronics
• ULc Approved FM Class 1, Div 2
• Rated NEMA 4X and NEMA 6
• Choice of 115–230 VAC or 12–24 VAC/VDC Power
• 3-Line, 20-Character Backlit Display
• Can be Ordered Blind (No Local Digital Display)
MAGFLO Verificator
SensorPROM
Memory Module
MAGFLO Mag 5000
• ±0.5% Accuracy with All Sensors
• 1 Current, 1 Digital, 1 Relay Output Standard
• Available with HART® Communication
• Only Available for Sensors 1/2” to 48”
Step 1: Choose your electronics by accuracy, power, and mounting style.
Add connecting cables and any accessories you need.
Communication
Modules
Wall mount Junction
Box for Mag 5000/6000
MAGFLO Mag 6000
• ±0.25% Accuracy with Selected Sensors
• Advanced Batch Control Functions
• Add-On Plug-In Communication Modules
• Required for Use with Sensors Larger than 56”
• Optional Design: Mag 6000i Industrial Enclosure
Step 2:Choose your flow sensor by size and liner material.
Issue your order to Siemens Industry Inc, c/o Lesman Instrument Company.
Model Selection Guide
Temperature Sensors
and Transmitters
Wireless Sensing and
Communications
Description
Catalog Number
Price
Mag 5000 Transmitters; Max. Measuring Error: 0.5% of Flow Rate
Integral Mount, 115-230 VAC
7ME6910-1AA10-1AA0 $1345.00
Integral Mount, 11-30 VDC 11-24 VAC
7ME6910-1AA30-1AA0
1345.00
Integral Mount, No Display, 115-230 VAC 7ME6910-1AA10-0AA0
1117.00
Integral Mount, HART®, 115-230 VAC
7ME6910-1AA10-1BA0
1555.00
Rack Mount, 115-230 VAC
7ME6910-2CA10-1AA0
1525.00
Mag 6000 Transmitters: Max. Measuring Error: 0.25% of Flow Rate
Integral Mount, 115-230 VAC
7ME6920-1AA10-1AA0
1584.00
Integral Mount, 11-30 VDC 11-24 VAC
7ME6920-1AA30-1AA0
1584.00
Rack Mount, IP20/NEMA 2, 115-230 VAC 7ME6920-2CA10-1AA0
1812.00
IP66/NEMA 4 ABS Plastic Enclosure,
115-230 VAC
7ME6920-2EA10-1AA0
1834.00
Mag 6000i Transmitter: Max. Measuring Error: 0.25% of Flow Rate
Remote Mount IP67/NEMA 4X
Aluminum Enclosure 10-220 VDC/AC 7ME6930-2BA20-1AA2
2095.00
Mounting Kits and Hardware
Wall Mount Junction Box IP67/NEMA 4X/6
FDK:085U1053
235.00
Submersible Kit for Terminal Box, for IP68,
10m w.g. Rating
FDK:085U0220
144.00
21TE Panel Mount Kit for 19” Insert
IP65/NEMA4 Enclosure in ABS Plastic
FDK:083F5030
398.00
21TE Back Panel Mount Kit for 19” Insert
IP20/NEMA 2 Enclosure in Aluminum
FDK:083F5032
182.00
Polyamide Terminal Box with Lid for
Field-Mount MAGFLO Sensors
FDK:085U1052
222.00
Connection Plate for 19” Rack Mount
FDK:083F4117
84.00
Brass Adapters, PG13.5 Male to 1/2” NPTF
FDK:A6X30005543
19.00
Analytical Instruments
and Systems
er?
the right magmet
g
in
nd
fi
lp
he
d
Nee
sheet
s application data back to
en
m
ie
S
e
th
t
ou
it
Fill
d fax
/datasheets/ an
from Lesman.com r engineering review.
Lesman fo
Description
Catalog Number
Price
Interconnect Cables (Price per foot, two lengths required per installation)
Standard Interconnect Cable FDK:001STCAB **
$3.00
Special Interconnect Cable (for Empty Pipe)
FDK:001SPCAB **
4.00
** Choose two standard or one standard and one special cables.
Both are PVC jacket, three-conductor plus overall braided shield.
Plug-In Communications Modules for Mag 6000 Electronics
Mag6000 HART Communication Module
FDK:085U0226
222.00
Mag 6000i HART Communication Module
FDK:085U0321
227.00
Mag 6000 Modbus RTU/RS485 Module
FDK:085U0234
222.00
Spare Parts and Accessories
Mag 5000/Mag 6000 Sensorprom 2KB
FDK:085U1005
69.00
Mag 5000/Mag 6000 Display Unit
FDK:085U1039
170.00
Sun Shield for Remote-Mt Polyamide Covers A5E01209496
229.00
Sun Shield for Integral Polyamide Covers
A5E01209550
368.00
MAGFLO Verificator
MAGFLO Verificator (With Software and
Adapter for IP67/Rack-Mount Models)
FDK:083F5061
18560.00
Great for Drinking Water Applications
Battery
Powered!
Flow Sensor Body Mag 8000W (Drinking Water) 0.5%
Accuracy, Battery-Powered Magmeter with Standard Mag5100W Sensor,
Integral Transmitter, and Integral Battery Pack (2 DCells). Qmax=Volume Unit
2” 277 GPM
7ME6810-2YJ31-2AA1 $3016.00
2.5” 440 GPM
7ME6810-3FJ31-2AA1
3027.00
3” 704 GPM
7ME6810-3MJ31-2AA1 3039.00
4” 1100 GPM
7ME6810-3TJ31-2AA1
3091.00
5” 1761 GPM
7ME6810-4BJ31-2AA1 3303.00
6” 2769 GPM
7ME6810-4HJ31-2AA1 3497.00
8” 4389 GPM
7ME6810-4PJ31-2AA1
3827.00
10” 7044 GPM
7ME6810-4VJ31-2AA1 4321.00
12” 11007 GPM
7ME6810-5DJ31-2AA1 5519.00
Now available with wireless interface. Call for details.
Visit www.Lesman.com for more information on Siemens’ line of SITRANS FM MagFlo magnetic flowmeters.
Get specs, manuals, and quick start guides.
Sensors for General Industrial Applications
Flow Sensor Body Mag3100: Neoprene Liner, 316SS Electrodes, ANSI Class
150 Carbon Steel Flanges, Carbon Steel Housing
1”
7ME6310-2DJ11-1AA2$1454.00
1.5”
7ME6310-2RJ11-1AA21473.00
2”
7ME6310-2YJ11-1AA21520.00
2.5”
7ME6310-3FJ11-1AA21544.00
3”
7ME6310-3MJ11-1AA21564.00
4”
7ME6310-3TJ11-1AA21632.00
6”
7ME6310-4HJ11-1AA22219.00
8”
7ME6310-4PJ11-1AA22769.00
10”
7ME6310-4VJ11-1AA23423.00
12”
7ME6310-5DJ11-1AA24824.00
Flow Sensor Body Mag3100P: PTFE Liner, Hastelloy C-276 Electrodes, ANSI
Class 150 Carbon Steel Flanges, Carbon Steel Housing
0.5”
7ME6340-1VJ13-2AA2$1871.00
1”
7ME6340-2DJ13-2AA21702.00
1.5”
7ME6340-2RJ13-2AA21733.00
2”
7ME6340-2YJ13-2AA21757.00
2.5”
7ME6340-3FJ13-2AA21781.00
3”
7ME6340-3MJ13-2AA21809.00
4”
7ME6340-3TJ13-2AA21899.00
6”
7ME6340-4HJ13-2AA22598.00
8”
7ME6340-4PJ13-2AA23826.00
10”
7ME6340-4VJ13-2AA25209.00
12”
7ME6340-5DJ13-2AA27352.00
Sensors for Food, Beverage, and Pharmaceutical Use
For Water and Wastewater Applications
Flow Sensor Body Mag1100: PFA Liner, Hastelloy-C Electrodes, Includes
EPDM Gaskets, SS Studs and Nuts
3/8” DN10
7ME6110-1RA10-1AA2
$1514.00
1/2” DN15
7ME6110-1VA10-1AA2
1514.00
1” DN25
7ME6110-2DA10-1AA2
1514.00
1.5” DN40
7ME6110-2RA10-1AA2
1793.00
2” DN50
7ME6110-2YA10-1AA2
2073.00
2.5” DN65
7ME6110-3FA10-1AA2
2200.00
3” DN80
7ME6110-3MA10-1AA2
2334.00
4” DN100
7ME6110-3TA10-1AA2
2868.00
Flow Sensor Body Mag1100: Ceramic Liner, Platinum Electrodes, EPDM Gaskets, SS Studs and Nuts
0.078” DN2
7ME6110-1DA20-2AA2
$1577.00
1/8” DN3
7ME6110-1HA20-2AA2
1577.00
1/4” DN6
7ME6110-1MA20-2AA2
1378.00
3/8” DN10
7ME6110-1RA20-2AA2
1378.00
1/2” DN15
7ME6110-1VA20-2AA2
1378.00
1” DN25
7ME6110-2DA20-2AA2
1378.00
1.5” DN40
7ME6110-2RA20-2AA2
1652.00
2” DN50
7ME6110-2YA20-2AA2
1928.00
2.5” DN65
7ME6110-3FA20-2AA2
2063.00
3” DN80
7ME6110-3MA20-2AA2
2202.00
4” DN100
7ME6110-3TA20-2AA2
2788.00
Flow Sensor Body Mag1100 Food: PFA Liner, Hastelloy-C Electrodes.
Select Tri-Clover® or Tri-Clamp® Sanitary Adapter Below
3/8” DN10
7ME6140-1RA10-1AA2
$1514.00
1/2” DN15
7ME6140-1VA10-1AA2
1514.00
1” DN25
7ME6140-2DA10-1AA2
1514.00
1.5” DN40
7ME6140-2RA10-1AA2
1793.00
2” DN50
7ME6140-2YA10-1AA2
2073.00
2.5” DN65
7ME6140-3FA10-1AA2
2200.00
3” DN80
7ME6140-3MA10-1AA2
2329.00
4” DN100
7ME6140-3TA10-1AA2
2759.00
Tri-Clover® Sanitary Weld-In Adapter: Includes 2
Clamp Fittings, 2 Clamps, and 2 EPDM Gaskets
3/8” (1/2” Tri-Clover) FDK:083G2276
$245.00
1/2” (3/4” Tri-Clover) FDK:083G2277
245.00
1”
FDK:083G2279295.00
1.5”
FDK:083G2281343.00
2”
FDK:083G2282369.00
2.5”
FDK:083G2283412.00
3”
FDK:083G2284499.00
4”
FDK:083G2285583.00
Flow Sensor Body Mag 5100W: Nitrile Rubber Liner, Hastelloy C Electrodes,
ANSI Class 150 Carbon Steel Flanges
1”
7ME6580-2DJ14-2AA2$1092.00
1.5”
7ME6580-2RJ14-2AA21105.00
2”
7ME6580-2YJ14-2AA21142.00
2.5”
7ME6580-3FJ14-2AA21154.00
3”
7ME6580-3MJ14-2AA21167.00
4”
7ME6580-3TJ14-2AA21217.00
5”
7ME6580-4BJ14-2AA21429.00
6”
7ME6580-4HJ14-2AA21623.00
8”
7ME6580-4PJ14-2AA21953.00
10”
7ME6580-4VJ14-2AA22447.00
12”
7ME6580-5DJ14-2AA23645.00
14”
7ME6580-5KJ14-2AA25052.00
16”
7ME6580-5RJ14-2AA25653.00
18”
7ME6580-5YJ14-2AA26283.00
20”
7ME6580-6FJ14-2AA26977.00
24”
7ME6580-6PJ14-2AA27755.00
Ideal for Applications with High
Concentration of Suspended Solids
(Pulp and Paper, Cement, Mining)
TransMag2 Electronics: Patented Pulsed AC Magnetic Flowmeter for High Suspended Solids. IP67/
NEMA 4X Enclosure, Max. Measuring Error 0,50%
Rate, 100–230 VAC Power; 1 Current, 1 Digital, 1
Relay (or 1 DI) Outputs
4-20 mA with HART Protocol
7ME5034-0AA11-2AA0
$2348.00
Profibus PA Protocol
7ME5034-1AA11-1AA0
2925.00
Mounting Bracket (Add Suffix to Model Number)
-A02
99.00
Flow Sensor Body 911/E for TransMag 2: PTFE Liner, Hastelloy C4 Electrode,
Remote Design, 1/2” NPT Screwed Gland, IP67/NEMA 5 Protection, ANSI Flanges
1”
7ME5610-2DJ13-2AA2$2785.00
1.5”
7ME5610-2RJ13-2AA22903.00
2”
7ME5610-2YJ13-2AA23130.00
2.5”
7ME5610-3FJ13-2AA23514.00
3”
7ME5610-3MJ13-2AA23636.00
4”
7ME5610-3TJ13-2AA23926.00
5”
7ME5610-4BJ13-2AA24100.00
6”
7ME5610-4HJ13-2AA24355.00
8”
7ME5610-4PJ13-2AA25673.00
10”
7ME5610-4VJ13-2AA26784.00
12”
7ME5610-5DJ13-2AA29108.00
14”
7ME5610-5KJ13-2AA2
9196.00
16”
7ME5610-5RJ13-2AA211011.00
Level Measurement
Instruments
Popular models in 1” to 12” sizes usually available
to ship within two weeks!
Flow Measurement
Instruments
69
Pressure Transmitter
MAGNETIC
FLOWMETERS
Temperature Sensors
and Transmitters
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Wireless Sensing and
Communications
www.lesman.com
[email protected]
Analytical Instruments
and Systems
Lesman Instrument Company
V 01.2016
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
CORIOLIS
FLOWMETERS
V 01.2016
Level Measurement
Instruments
70
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Lesman Instrument Company
www.lesman.com
[email protected]
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
SITRANS FC Coriolis Mass Flowmeters
Flow Measurement
Instruments
Mass 2100 Coriolis Mass Flow Sensor
FC300 Coriolis Mass Flow Sensor
• Accuracy >0.1% mass flow rate
• Dynamic turndown ratio >500:1, from
65 kg/h to a few g/h
• Densitometer performance available
(Accuracy >0.001 g/cm3, repeatability
>0.0002 g/cm3)
• Single continuous tube design, with
no internal welds, reductions or flow
splitters offers optimal hygiene, safety
• Market’s biggest wall thickness
ensures optimal corrosion resistance
and high-pressure durability
• Intrinsically safe Ex ia standard
• Accuracy >0.1% mass flow rate
• Dynamic turndown ratio >500:1
• One tube with no internal welds,
reductions, or flow splitters
• Balanced pipe design ensures
optimal stability under harsh and
unstable process conditions
• Four-wire Pt1000 temperature measurement for accurate mass flow,
density and fractional flow
• Intrinsically safe Ex ia IIC standard
Pressure Transmitter
MASS 2100 coriolis mass flow sensor is designed for low flow measurement in liquids and gases. One unit measurs mass flow, volume
flow, density, temperature and fraction. MASS 2100 can be connected
to MASS 6000 transmitters for remote installation only.
Specifications
Temperature Sensors
and Transmitters
Pipe: Inside Diameter: 1.5 mm (0.06”); Wall Thickness: 0.25 mm (0.010”)
Measuring Range: Mass Flow: 0–143 lb/h; Density: 0–0.10 lb/in3; Fraction:
0–100° Brix; Temperature: -58° to 257° F (Optional 356° F);
Liquid Pressure Measuring Pipe: Stainless steel: 3336 psi at 68° F; Hastelloy
C22/2.4602: 5294 psi at 68° F
Construction: Measuring pipe/connection: 316L stainless steel; Hastelloy
C22/2.4602; Enclosure: IP65 316L stainless steel
Connection: 1/4” NPTM ANSI/ASME B1.20.1
Approval: Ex ia IIC T3-T6, DEMKO 03 ATEX 135252X
Mass 6000 Mass Flow Transmitter
Wireless Sensing and
Communications
Analytical Instruments
and Systems
• For mass flow rate, volume flow rate,
density, temperature, fraction flow
(e.g., Brix)
• One current output, one frequency/
pulse output, one relay output, one
digital input; All outputs can be
individually configured with mass,
volume, or density
• Adjustable flow direction, with single
and bidirectional flow measurement
• Limit switches with one or two limits,
programmable for flow, density or
temperature
• Full batch controller
• Two built-in totalizers count positive, negative or net
• Noise filter for performance in tough environments
• Auto zero adjustment with zero point evaluation feedback
• Full service menu for effective use and troubleshooting
• Compatible with MASS 2100, FC300 and other flow sensors
SITRANS FC300 sensor offers superior performance in flow and density accuracy, and turndown ratio. The compact enclosure fits in tight
installation spaces for measuring liquids and gases. It can be installed in
horizontal or vertical position. FC300 can be connected to MASS 6000
transmitters for remote installation only.
Specifications
Sensor Size: DN 4 (1/6”)
Mass Flow: Range: 0–772 lb/h; Accuracy: 0.1 % of rate; Repeatability: 0.05 of
rate; Max. Zero Point Error: 0.022 lb/h
Density: Range : 0–0.105 lb/in3; Density Error: 0.00025 lb/in3; Repeatability
Temperature: -40° to 239° F (Optional to 356° F); Temperature Error: 0.9° F
Brix: 0–100°; Error: 0.3° Brix
Pipe: Inside diameter: 0.14“; Wall thickness: 0.0098“; Liquid pressure measuring
pipe: 1885 psi at 68° F
Construction: 316L stainless steel; Measuring pipe/connection: Hastelloy
C22/2.4602; Enclosure: IP67/NEMA4 316L stainless steel
Connection: 1/4” NPTM, ANSI/ASME B1.20.1
Approval: UL Class 1 Div. 1, Groups A–D, ATEX
Specifications
t mass
Learn more abou
sman.com.
flowmeters at Le
Current Output: 0/4–20 mA;
Load: < 800 Ω; Time constant: 0–99.9s adjustable
Digital Output: Frequency: 0–10 kHz, 50 % duty cycle; Time constant: 0–99.9s
adjustable; Active: 24 VDC, 30 mA; Passive: 3–30 VDC, max. 110 mA
Change-Over Relay: Load: 42 V/2 A peak; Functions: Error level, error number,
limit, flow direction
Digital Input: 11–30 VDC; Start/hold/continue batch, zero point adjust, reset
totalizer 1/2, force output, freeze output
Cut-Off: Low-flow 0–9.9% max flow; adjustable density or empty pipe cutoff
Limit Function: Mass flow, volume flow, fraction, density, sensor temperature
Totalizer: Two eight-digit counters for forward, net or reverse flow
Display: Backlit alphanumerical text, 3 x 20 characters for flow rate, totalized
values, settings and faults. Reverse flow indicated by negative sign
Zero Point Adjustment: Via keypad or remote via digital input
Communication: Add-on modules: HART®, PROFIBUS PA and DP, MODBUS
RTU RS-485, DeviceNet, FOUNDATION Fieldbus H1
Enclosure: Rating IP67/NEMA 6 Fiberglass reinforced polyamide;
Supply Voltage: 24 VDC/AC, 50–60 Hz
NAMUR: Within the value limits according to "General requirements“ with
error criteria A in accordance with NE 21
Cable Glands: Two 1/2” NPT or M20 polyamide cable glands
SITRANS FC430 Coriolis Mass Flowmeter
• Compact design: Install anywhere,
fit multiple units into tight spaces;
Sizes available from 1.2” to 3”
• Flange, pipe thread, hygienic
thread and hygienic clamp connections available
• HemiShape flow manifold
for low pressure loss; Avoids
cavitation and separation of
fragile fluids; Ideal for hygienic use (EHEDG/3A approved)
• 4-20 mA analog output with HART®
7.2 standard. Other I/O can be configured for analog, pulse,
frequency, relay, or status
• FCT030 transmitter available in remote and compact versions, mountable on all FCS400 sensor sizes DN15 to DN80
• Fully rotatable (0-180°) pedestal makes access possible from
all sides, includes simple one-bolt release clamp
Streamlined, compact SITRANS FCS400 sensor
The SITRANS FCS400 coriolis mass flow sensor was designed for superior
performance and reliability: a very stable zero point, low pressure loss,
and high immunity to process noise and plant vibrations.
FCS400 is the most compact sensor available in today’s mass flowmeter market. The small size makes installation and replacement easy, and
possible to fit multiple units into tight spaces.
The Siemens CompactCurve tube shape offers a 0.1% flow rate accuracy
and high sensitivity for optimal measurement, even with very low flows.
The unit is self-draining and highly resistant to pressure burst. The ultrashort tube provides better than 1 kg/m3 density accuracy.
HemiShape flow manifold design ensures balanced flow between
tubes and makes the FC430 great for use in fragile liquids. It includes
purge connectors for monitoring, safety relief valves, and rupture discs.
The unique design secures low pressure loss and avoids cavitation at the
separation of fragile liquids — ideal in hygienic applications. Its smooth
surface allows for easy cleaning with minimal flow abstraction.
Models can be ordered for standard, hygienic, or NAMUR service, and
can be validated and configured for SIL2 or SIL3 operation standard. (SIL3
requires two flowmeters in series, monitored by a SIL-rated control system).
SITRANS FCS400 Sensor Specifications
Sizes:
DN15 (1/2”) DN25 (1”)
DN50 (2”) DN80 (3”)
Flow Range (Lb/h):8,157 25,353 114,640 300,000
Accuracy: ±0.10%; Repeatability: ±0.05%
Pressure rating: Measuring tube: 1450 PSI; Sensor enclosure: 20 bar for 1/2”
and 1” models, 17 bar for 2” and 3” models
Temperature: Process: -58° to 392° F; Ambient: -40° to 140° F
Material: Wetted parts: 316L SS; Enclosure: IP67-rated 304 SS
Process connections: Flanges: EN1092-1 B1 and D, ANSI/ASME B16.5, JIS; Pipe
threads: ASME (NPT), BSPP, VCO Quick-Connect; Hygienic threads: DIN11851,
DIN11864-1, ISO2853, SMS1145; Hygienic clamps: DIN11864-2, DIN32676,
ISO2853, SMS1145
Approvals: Hazardous area: ATEX, IECEx, FM, NEPSI, CSA, TISS, GOST; Pressure
equipment: PED, CRN; Hygienic: 3A, EHEDG; Custody transfer: SITRANS FC430
OIML R 117; Operational safety: SIL2
• Can be validated and configured for SIL2 or SIL3 operation
• Meets all IEC Ex, ATEX, and FM hazardous area requirements
• Standard Siemens local user interface (LUI): Reduces training needs for added cost and time-efficiency. Full graphical
display, straight-forward commissioning, simple navigation,
customized top-level views, standard programming wizards
provide guidance for the inexperienced user
• Superior isolation and resistance against
external vibrations for 0.1% accuracy,
0.05% repeatability, and no twisting
• MicroSD card stores user and factory settings, calibration data and certificates. For
audit trails and quick transfer of information to PC or between transmitters
• Remote FCS400 model’s digital sensor link guarantees high-speed data
transfer, even with up to 200 meters
between sensor and transmitter
One SITRANS FC coriolis mass flowmeter can measure:
Mass Flow Rate
Total Mass
Density
Temperature
Brix
Volumetric Flow Rate
Level Measurement
Instruments
Need help choosing a coriolis mass flowmeter? Not sure coriolis is right for your application? Fill out
the application datasheet from www.Lesman.com/datasheets and fax it back to Lesman.
Flow Measurement
Instruments
71
Pressure Transmitter
CORIOLIS
FLOWMETERS
Total Volume
Fraction Flow
% or Total Fraction
Innovative and user-friendly SITRANS FCT030 transmitter
Based on patented digital signal processing technology, the SITRANS
FCT030 transmitter delivers true multi-parameter measurements with
enhanced efficiency, security and simplicity. Fully modular for installation
and replacement; can be remote or compact mounted with all SITRANS
FCS400 sensor sizes.
Fully graphical interface display can be customized to show you different information during measurement and diagnostics. Measurement
views include multivariable numeric display, bar graphs, and trend curves.
On-screen diagnostics include timestamp and NAMUR results.
Four navigational buttons, help text, and wizards for processes make
servicing the transmitter easy. The common Siemens menu structure,
display layout, and input methods reduces the need for user training.
The SensorFlash MicroSD card serves as a removable database of
operational user information and provides direct access to all relevant
certificates and audit trails.
SITRANS FCT030 Transmitter Specifications
Input/Output Channels: Up to 4 channels combining analog, relay or digital
outputs and binary input
Signal Processing: 100 Hz
Communication: HART 7.2
Power supply: 24-90 VDC, 100-240 VAC
EMC performance: EN 61326-3-2
Local User Interface (LUI): Full graphical display, 240 x 160 pixels
Construction: IP67-rated aluminum with corrosion-resistant coating
Mechanical load: 18 to 1000 Hz random, 3.17 G rms, in all directions
Approvals: Hazardous areas: ATEX, IECEx, FM, NEPSI, CSA, TISS, GOST; Hygienic:
3A; NAMUR; Custody transfter: SITRANS FC430 OIML R 117; Operational safety:
SIL3 (transmitter and redundant system)
Temperature Sensors
and Transmitters
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Wireless Sensing and
Communications
www.lesman.com
[email protected]
Analytical Instruments
and Systems
Lesman Instrument Company
V 01.2016
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
ULTRASONIC
FLOWMETERS
V 01.2016
Level Measurement
Instruments
72
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Lesman Instrument Company
www.lesman.com
[email protected]
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
SITRANS F US Clamp-On Ultrasonic Flowmeters
Comparing SITRANS F US Clamp-On Flowmeter Configurations
Model
Flow Measurement
Instruments
Replaces...
SITRANS FTS020
Basic
SITRANS FUS1010
Standard
SITRANS FUP1010
Portable
FUE1010
Energy Industry
Applications
FUH1010
Hydrocarbon Industry
Applications
FUG1010
Gas Industry
Applications
Controlotron
1020
Controlotron
1010N, 1010X,
1010WX
Controlotron
1010P,
1010WP
Controlotron
1010EN,
1010EP
Controlotron
1010DV, 1010V, 1010B
Controlotron
1010GC
±40 ft/sec (±12 m/s) bidirectional
Flow Range
Pressure Transmitter
Flow
Sensitivity
0.001 ft/sec
(0.0003 m/sec) flow
rate independent
0.001 ft/sec (0.0003 m/sec) flow
Temperature Sensors
and Transmitters
Optional
Inputs
None
Outputs
4–20 mA DC
1x for single channel
1x 0–5 kHz pulse rate,
digital isolated
RS232
Accuracy
1–2% actual volume
reading
(Higher accuracy is
dependent on pipe
condition)
Wireless Sensing and
Communications
±0.15–1.0% flow
0.05–0.1% actual volume reading for 5-100
ft/sec (1.5–30 m/sec)
velocities, pipe condition dependent
Two 4–20 mA DC, Two 0–10 VDC, Two 4-Wire 1kΩ
RTD
±0.5–1.0% flow for
velocities >1 ft/sec (0.3
m/sec)
±0.005–0.01 ft/sec
(±0.0015–0.003 m/sec)
for velocities <1 ft/sec
(0.3 m/sec)
Analytical Instruments
and Systems
Approvals
Prices Start at
±0.5–2.0% flow for
velocities >1 ft/sec (0.3
m/sec)
±0.005–0.01 ft/sec
(±0.0015–0.003 m/sec)
for velocities <1 ft/sec
(0.3 m/sec)
±0.5–1.0% flow for
velocities >1 ft/sec (0.3
m/sec)
±0.005–0.01 ft/sec
(±0.0015–0.003 m/sec)
for velocities <1 ft/sec
(0.3 m/sec)
±0.15% flow for velocities >1 ft/sec (0.3 m/sec)
±0.0015 ft/sec (0.0005 m/sec) for velocities <1 ft/sec (0.3 m/sec)
5 Hz
NEMA 4/IP65
Liquid
Temperatures
Power Supply
Two 4–20 mA DC, Two
0–10 VDC, Two 4-Wire
1000Ω RTD, Totalizer
commands (clear/hold)
Two 4–20 mA DC (1kΩ at 30 VDC), Two 0–10 VDC (5kΩ min.),
Four SPDT relays for status alarms, Two 0–5 kHz frequency, RS232
Data Refresh
Enclosure
Ratings
1” to 60”
(DN 25 to DN 152)
0.25” to 360” (DN 6.4 to DN 9140)
Pipe Sizes
Batch
Repeatability
0.001 ft/sec (0.003 m/sec) flow rate independent
NEMA 4X/IP65, NEMA
7/IP65, NEMA 7/IP66
Four 4–20 mA user
selectable, Two 4-Wire
1000Ω RTD
Two 4–20 mA, Two
4-Wire 1000Ω RTD
Two 4–20 mA DC (1kΩ
at 30 VDC), Two 0–10
VDC (5kΩ min.), Four
0–5 kHz pulse rate
(None for NEMA 7/IP65
version), RS232
Two 4–20 mA DC programmable standard,
Two 0–10 VDC, Four
0–5 kHz, RS232
0.5–1.0% flow, calibratable to 0.15–0.3%
of flow, 0.05 of API
number (interface
detector)
Out of box 1-2%, calibratable to 0.5%
±0.005–0.01 ft/sec
(±0.0015–0.003 m/sec)
for velocities <1 ft/sec
(0.3 m/sec)
0.05% (depending on
model)
±0.10–0.2% flow for
velocities >1 ft/sec (0.3
m/sec)
±0.15% flow for velocities >1 ft/sec (0.3 m/
sec)
±0.0015 ft/sec (0.0005
m/sec) for velocities <1
ft/sec (0.3 m/sec)
5 Hz (80 Hz output optional)
IP67
NEMA 4X/IP65,
NEMA 1/IP40
NEMA 4X/IP65, NEMA 7/IP65, NEMA 7/IP66
-40° to 250° (-40° to 120° C) standard; -40° to 450° F (-40° to 230° C) optional
-40° to 140° F
(-40° to 60° C)
Call for higher temps.
100–240 VAC, 50/60 Hz,
30 VA, 9–36 VDC, 12W
90–240 VAC, 50/60 Hz,
30 VA, 9–36 VDC, 12W
100–240 VAC, 50/60 Hz,
9–36 VDC, 10W
Internal NiCad battery
(4 hour)
90–240 VAC, 50/60 Hz, 30 VA, 9–36 VDC, 12W
90–240 VAC, 50/60 Hz, 15 VA or 9–36 VDC, 10W
FM, CSA, ATEX, INMETRO, GoST
90–240 VAC, 50/60 Hz
30 VA or 9–36 VDC,
12W
UL, ULc, CE
FM, CSA, ATEX, CCOE,
INMETRO, GoST
UL, ULc, CE
FM, CSA, CE (fixed)
UL, ULc, CE (portable)
$3509.00
$3857.00
$5136.00
$4697.00
$7595.00
$9141.00
Engineering specifications and more available online.
Learn more about Siemens SITRANS F US
Clamp-On Ultrasonic Flowmeters by visiting
www.Lesman.com/get/SICF.php
Don’t guess how much money’s
flowing through your pipe.
Clamp-on and know!
• Measure practically any liquid and gas
• Performance unaffected by viscosity, flow rate, pipe size,
solids and aeration content
• High accuracy and repeatability through automatic temperature compensation and zero drift correction
• Install on pipe sizes up to DN9140 (360”)
With no moving parts to wear or foul, no need to cut the pipe for
installation, and high accuracy WideBeam ultrasonic flow measurement
technology, you have nothing to lose.
Siemens’ clamp-on ultrasonic flow technology offers several advantages over other flow measurement methods. Transducers mount
quickly and easily on the outside of the pipe, so they’re ideal for retrofit
applications or anywhere corrosive, toxic or high pressure liquids and
gases rule out the option of cutting the pipe.
The Transducer is Key
Transducers for Siemens ultrasonic
clamp-on flowmeters are available with
Doppler and WideBeam transit time measurement technologies, so there’s a solution
to work in practically any installation.
Doppler operation is suggested for
liquids with extensive suspended solids or
aeration, and offers up to 2% flow accuracy.
WideBeam transit time operation is the preferred mode for relatively homogeneous
liquids. Accuracy is up to 0.5% of the flow.
The patented WideBeam technology
increases measurement precision by reducing the sensitivity to any change in
the medium type or physical properties. The signal-to-noise ratio is
optimized by using the resonant frequency of the pipe wall to transmit
the sound signal into the media, with the wall acting as a waveguide. This
method produces a focused, coherent signal that makes the technology
particularly valuable for hydrocarbon and gas applications.
For added flexibility, flowmeters are available that allow switching
between Doppler and WideBeam to quickly adapt to varying conditions
without changing meters.
SITRANS FUS1010: Versatility and Flexibility
Ultrasonic flowmeters can be used
within a wide variety of applications
and industries, so they’re quickly becoming the metering technology of
choice. The versatile SITRANS FUS1010
illustrates this perfectly.
It offers numerous advantages in
application adaptability that cannot
be matched by any other single flow
measurement technology: zero pressure drop, insensitivity to outside
noise, high turn-down ratio, interface software, and WideBeam and
Doppler modes.
The SITRANS FUS1010 is available in single, dual
channel/beam, and four channel configurations
plus your choice of three enclosures: NEMA 4X/IP65
wall mount, NEMA 7/IP65 compact, and NEMA 7/
IP66 wall mount.
To accommodate more basic applications, the
low cost SITRANS FTS020 comes with WideBeam
and as single and dual channel versions, allowing
either one or two measurement points.
SITRANS FUP1010 Portable Flowmeter for Check Metering
and Survey Applications
For applications that don’t need constant flow monitoring or pipes
where operators need to check the flow against a known or expected
value, Siemens offers portable clamp-on ultrasonic flowmeters.
The SITRANS FUP1010 is available with a waterproof IP67 enclosure
that makes it ideal for outdoor use. The rugged, impact resistant plastic
case simply enables it to withstand rough treatment that would damage
most other meters.
SITRANS FUP1010 operates on AC or DC power. It has an internal battery
that provides 4 hours of operation and can be recharged in 1.5 hours.
Temperature Sensors
and Transmitters
Flowmeter
configuration...
there’s an App
for that!
Since the accuracy of a clamp-on ultrasonic flowmeter depends on
choosing the right transducer, this is a crucial step in the meter configuration. Siemens offers four types of transducers: universal, universal high
temperature, high precision and Doppler. Before deciding on the most
appropriate transducer, consider these factors: pipe thickness, diameter
and material, liquid/gas type, and amount of aeration.
By evaluating all of these aspects before choosing your final configuration, you are sure that your meter will work exactly the way you want it,
right from day one. With flexible configuration options combined with
permanent and portable versions, finding exactly what you need has
become a lot easier.
Customize your flowmeter by choosing necessary transducers, number of channels and enclosures, or select a complete pre-configured
system available for HVAC, power, and hydrocarbon
industries.
As a crucial accessory, the clamp-on program also
includes an easy-to-use, stand-alone digital ultrasonic
pipe wall thickness gauge. Since even the smallest
pipe thickness miscalculations can have an impact on
accuracy, this high precision gauge is an indispensable flow measurement tool.
Level Measurement
Instruments
73
Flow Measurement
Instruments
ULTRASONIC
FLOWMETERS
Pressure Transmitter
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Wireless Sensing and
Communications
www.lesman.com
[email protected]
Analytical Instruments
and Systems
Lesman Instrument Company
V 01.2016
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
ULTRASONIC
FLOWMETERS
V 01.2016
Level Measurement
Instruments
74
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Lesman Instrument Company
www.lesman.com
[email protected]
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
SITRANS F US Clamp-On Ultrasonic Flowmeters
Flow Measurement
Instruments
Pressure Transmitter
With the dual channel version, switching between WideBeam and
Doppler operation for quick adaptation to varying conditions can take
place without changing meters. This makes is suitable for any liquid; even
those with high aeration or suspended solids. Using the meter’s internal
datalogger, process history can be recorded and stored or downloaded
to a PC or laptop.
Check Metering Kits
Temperature Sensors
and Transmitters
If you need a portable meter that needs to be
moved often as part of a flow survey or flow check
measurement, pre-configured check metering kits
are the ideal solution. They can be used for checking the performance and accuracy of any type and
brand of flow or energy meter.
Kits come in rugged, weatherproof rolling cases with telescoping
handles. The case holds all the equipment — cables, multiple transducers
and the ultrasonic flow computer; no need to order extra parts.
Clamp-on ultrasonic check metering kits are available for water and
wastewater, oil and gas, and energy industry applications.
Water and Wastewater Application Solutions
Wireless Sensing and
Communications
Ultrasonic WideBeam transit time and Doppler flowmeters are engineered to measure a wide range of flow applications found in the
municipal water and wastewater industries.
They can be mounted on any pipe size and material, and range from
simple single meter installations to full flow metering or leak detection
systems in large distribution and collections systems plants.
Single, dual or four channel configurations facilitate the installation
on a very wide range of applications. Dual channel meters can be set
up on two separate applications and can also provide math functions
between the two channels. The same applies for the four channel meter,
which can monitor four lines and also has math and multipath functions.
and specific gravity at base temperature and pressure at both reference
and current operating conditions.
The SITRANS FUH1010 for accurate standard volume/mass flow measurement is required for high end application such as varying viscosity
liquids and multi-product pipelines. It’s also ideal for line balance applications that require normalized volume or mass output.
Outputs are available for density and API. For even more precise density
compensation, analog inputs from densitometers, temperature sensors,
viscometers and pressure transmitters can be used.
SITRANS FUE1010 for Energy and Power Applications
The rugged, high precision SITRANS FUE1010 flowmeter is ideally
suited for thermal energy and power applications, and large pipe sizes.
Key applications include high precision revenue grade sub-metering
of thermal energy production, chilled or hot water HVAC installations,
measurement of ammonia and glycol mixtures, and energy efficiency
monitoring of HVAC equipment and nuclear power plants.
As a stand-alone energy meter, the FUE1010 can be used as a remote
communication module. Inputs from other data sources are transferred
into the built-in data logger, making it easy to time-stamp all data and
download it for billing, efficiency and operation analysis.
SITRANS FUH1010 for Hydrocarbon Industry Applications
Analytical Instruments
and Systems
Siemens SITRANS FUH1010 meters are specifically designed to address
the needs of the hydrocarbon industry in applications where traditional
meters cannot perform.
• Continuous operation with highly aerated liquids
• Flow measurement under a wide range of viscosities
• Easy and quick installation with zero process down time
• High performance under less than ideal flow profile conditions
SITRANS FUH1010 flowmeters are ideal for crude oil, refined petroleum
or liquefied gas applications. They are available in single, dual, three or
four beam versions and use WideBeam technology for maximum accuracy.
Clamp-on flowmeters for the hydrocarbon industry are available in
three different versions. The temperature- and pressure-compensated
SITRANS FUH1010 interface detector offers extremely precise interface,
crude oil and multi­product identification. It is ideal for scraper “pig” and
density indication. The system provides outputs for API number, density,
Flowmeter Software for Diagnostics and Data Analysis
Easy to use DataView software provides diagnostic capabilities, data
logging and trending of meter performance. This diagnostic assures
calibration and operational integrity. AGA-10 speed of sound calculation is incorporated in the software for speed of sound verification.
An internal AGA-8 table for fixed gas composition is available for
standard volume computation. Single, dual, or optional four beam
versions are available along with rugged, stainless steel transducer
enclosures permit permanent and direct burial installations.
Quick Configurations for Popular Models
FUS1010 standard clamp-on flowmeter,
NEMA 4/IP65 enclosure. Includes two 0-10
VDC, two 4-20 mA and two 0-5 kHz pulse outputs and four Form C relay outputs, 90-240 VAC
power, RS232 Modbus RTU communications.
Model Selection Guide
Issue all orders to: Siemens Industry Inc,
c/o Lesman Instrument Company
Description
FUS1010 Standard Clamp-On Flowmeter
Channels/ Single Channel
Beams
Dual Channel/Dual Beam
No Sensor
C3 Universal, 13” Mounting Frame
Channel 1 D3 Universal, 24” Mounting Frame
Transducer D1H High Precision 48” Mounting Frame
D2H High Precision 48” Mounting Frame
Doppler Strap Kit up to 12”
Channel 2 No Transducer
Transducer D1H High Precision 48” Mounting Frame
Doppler Strap Kit up to 12”
ID Tag
Stainless Steel, Max 68 Characters
1 x PVC-Jacket, 20’
Sensor
1 x PVC-Jacket, 50’
Cable
1 x PVC-Jacket, 100’
1 x PVC-Jacket, 150’
1 x PVC-Jacket, 200’
Catalog
NumberPrice
7ME3530- $3857.00
1AA00-
0.00
2AA00-
949.00
0A_ _
0.00
0D_ _
1621.00
0E_ _
1621.00
0P_ _
2147.00
0Q_ _
2345.00
0S_ _
903.00
_ _A1
0.00
_ _P1
2147.00
_ _S1
903.00
,Z-Y19
93.00
,Z-K01
109.00
,Z-K02
121.00
,Z-K03
213.00
,Z-K04
354.00
,Z-K05
400.00
FUP1010 portable clamp-on flowmeter, IP67
weatherproof, battery powered. Includes RTD
mounting hardware and cable, pipe mounting kit
and spacer bars for each transducer. Call for high
temperature transducers.
Model Selection Guide
Issue all orders to: Siemens Industry Inc,
c/o Lesman Instrument Company
Description
FUP1010 Portable Clamp-On Flowmeter
Channels/ Single Channel
Beams
Dual Channel/Dual Beam
No Sensor Cable
Sensor
1 x PVC-Jacket, 20’
Cable
2 x PVC-Jacket, 20’
1 x PVC-Jacket, 50’
2 x PVC-Jacket, 50’
Battery
None
Charger
Charger Type K for U.S. (NEMA 5-15P)
No Transducer
Channel 1 A2 Universal, 3” Track Mount
Transducer B3 Universal, 5” Track Mount
C3 Universal, 13” Mounting Frame
ID Tag
Stainless Steel, Max 68 Characters
Catalog
NumberPrice
7ME3510- $5136.00
10C _ _ _-
0.00
20C _ _ _- 1033.00
_ _ _A0 _-
0.00
_ _ _B0 _-
140.00
_ _ _C0 _-
280.00
_ _ _D0 _-
185.00
_ _ _E0 _-
370.00
_ _ _ _ 0-
0.00
_ _ _ _ 5-
171.00
0AA0
0.00
0BA0
1588.00
0CA0
1588.00
0DA0
1968.00
,Z-Y19
93.00
Siemens portable clamp-on ultrasonic flowmeters
are available for rent for survey metering
applications.Call for details.
FST020 basic clamp-on flowmeter, NEMA 4/
IP65. Includes one 4–20 mA output per channel
and 1 pulse output (single channel model only.)
Transducer includes pipe mounting kit. Unit is
UL, cUL, and CE approved standard.
Model Selection Guide
Issue all orders to: Siemens Industry Inc,
c/o Lesman Instrument Company
Description
FST020 Basic Clamp-On Flowmeter, NEMA 4/IP65
Channels
Single Channel
Meter
100–240 VAC
Power
11.5–28.5 VDC
No Transducer
Channel 1 B3 Universal, 5” Track Mount
Transducer C3 Universal, 13” Mounting Frame
D3 Universal, 24” Mounting Frame
B2H High Precision, 5” Track Mount
Sensor
No Cables
Cables
1 x PVC-Jacket, 20’
1 x PVC-Jacket, 50’
ID Tag
Stainless Steel, Max 68 Characters
Catalog
NumberPrice
7ME3570- $3509.00
1H _ _ _-
0.00
_ _ A00-
0.00
_ _ B00-
0.00
0A _ _
0.00
0C _ _
1453.00
0D _ _
1584.00
0E _ _
1584.00
0L _ _
1636.00
_ _ A0
0.00
_ _ B0
107.00
_ _ C0
118.00
,Z-Y19
93.00
Program your flowmeter
with an iPhone or iPad
SITRANS CONNECTION App for Apple iOS devices enables
direct serial communication between an iPhone, iPad, or
iPod touch and any SITRANS F US clamp-on ultrasonic flow
meter to enhance all meter functions, like programming,
operational review, and data logging and download.
SITRANS CONNECTION App makes connectivity possible
without needing a laptop PC. It simplifies programming with
a full alphanumeric keypad for easier navigation and parameter entry.
Plus, it lets you share access to your terminal window with a qualified
service technician (Wi-Fi or cellular service required).
How to Order
Flowmeter
You can order the SITRANS CONNECTION
configuration...
IOS app through the Apple iTunes store or
there’s an App
from Siemens. When you order the software
for that!
from Siemens, you’ll receive an iTunes
redemption code. At that point, you can
download the app from the iTunes store.
You will need to purchase a Siemens
cable kit to connect your Apple device to the Siemens clamp-on ultrasonic flowmeter. Select the cable (or cables) you need based on your
flowmeter model.
Model Selection Guide
Description
SITRANS Connection App: iTunes Redemption Code
Cable Kit–IP67 FUP Weather Proof Portable Meter
Cable Kit–IP65 FUE, FUG, FUH, FUS Meter (No Ext I/O)
Cable Kit–IP65 FUE, FUG, FUH, FUS Meter (with Ext
I/O), IP40 FUE Portable, FUT, FST020
Catalog No.
A5E32299678
A5E32299677
A5E32299675
Price
$15.00
242.00
184.00
A5E32299674 140.00
Compare SITRANS F US flowmeter models on page 72.
Flow Measurement
Instruments
Level Measurement
Instruments
75
Pressure Transmitter
ULTRASONIC
FLOWMETERS
Temperature Sensors
and Transmitters
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Wireless Sensing and
Communications
www.lesman.com
[email protected]
Analytical Instruments
and Systems
Lesman Instrument Company
V 01.2016
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
OPEN CHANNEL
FLOW MONITOR
V 01.2016
Level Measurement
Instruments
76
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Lesman Instrument Company
www.lesman.com
[email protected]
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
SITRANS LUT440 Open Channel Flow Monitor
Flow Measurement
Instruments
• Industry-leading accuracy to ±0.04” (1 mm)
• Next generation Sonic Intelligence — improved performance in noisy environments
• Echo profile and trend view on the display for enhanced diagnostics
• Energy-saving algorithms and real time clock help you reduce pump operation
cost by avoiding peak energy periods
• HART® communications with access via panel interface,
SIMATIC PDM, Emerson handhelds, and web-browser
• Graphical Quick Start Wizards guide you through setup
• Front interface with four-button programming, menu-driven
parameters, and Wizard support
Replaces
• Datalogger records performance and alarm events
retired
• Wall, pipe, and DIN rail mounting configurations
Siemens
• Removable terminal strips for hassle-free wiring
Milltronics
OCM-III
Pressure Transmitter
A complete LUT440
system includes:
s
See transducer
5.
-3
34
on pages
1.Controller
2. Echomax transducer
3. Additional cable lengths, as
necessary
4. Optional sensor mounting
flanges and aiming kits, as
necessary
Temperature Sensors
and Transmitters
An ultrasonic transducer above the primary
device emits a pulse that
strikes the liquid target
and is reflected back as
an echo.
The transmit and return
times are converted to
digital indications of head,
flow rate, and totalized
flow.
Specifications
Wireless Sensing and
Communications
Analytical Instruments
and Systems
Range: 1 to 200 ft, transducer and material dependent
Accuracy: ±1 mm (0.04”) plus 0.17% distance; High accuracy: ± 0.04” (1 mm), within 10 feet (3 m) range
Resolution: Greater of 0.1% measured range or 0.08”
Temperature: Ambient: -4° to 122° F (-20° to 50° C); Application: -40° to 302° F (-40° to 150° C)
Interface: Back-lit LCD; Removable display, operational
up to 5 m (16 ft) from enclosure base
Communications: HART®, USB
Programming: Four local push buttons, SIMATIC PDM
Emerson AMSTM, web browser (Internet Explorer), Field
Device Tool (DT), Emerson FC375/FC475
Output: Three relays: One Form C (SPDT) relay, two Form
A (SPST) relays; One 4–20 mA output (active or passive)
Input: Two discrete inputs (0-50 VDC max switching level)
with 24 VDC bias for contact level device and/or pump
interlock; One temperature sensor input for optional
TS-3 temperature sensor
Enclosure: Wall/Pipe/DIN Rail mount; 1/2 DIN; Type 4X/
NEMA 4X/IP 65, panel mount display IP 54 (Type 3/
NEMA 3/IP 54); Polycarbonate. Use of the knock-out
on the blind lid for the panel mount version reduces the
electronics enclosure rating to IP 20/NEMA 1.
Power: AC version: 100 to 230 VAC ±15%, 50/60 Hz, 36 VA
10 W; DC version: 10 to 32 VDC 10W
Approvals: General purpose: CE.CSAUS/C, FM, UL Listed,
C-TICK; Hazardous location: CSA Class I, II, III, Division 2
(Groups A–G), CE, ATEX 3D, IECEx, C-TICK
Ordering Instructions
Select one option from each table section below. A complete catalog number looks like this:
7ML5050-_ _ _ _ _ - _ _ _ _ -Z
Model Selection Guides
Please submit orders to: Siemens Industry Inc,
c/o Lesman Instrument Company.
Description
SITRANS LUT440 Ultrasonic Open Channel Flow Monitor
Enclosure With display
Display
With remote panel mount display
Options
No display (blank lid provided)
Input
100 to 230 VAC ± 15%
Voltage
10 to 32 VDC
Cable Inlet 3 cable inlets, cable glands not supplied
3 cable inlets, 3 M20 cable glands supplied
Approvals General purpose CE, FM, CSA US/C, UL, C-TICK
CSA Class I, II, III, Div 2 Groups A–G
Optional
Manufacturer’s test certificate
Adders
Stainless steel tag: Max. 27 char plain text
Preset Namur NE43 failsafe setting – <3.6mA
Documen- Printed English User Manual
tation
Printed Quick-Start Guide
Printed Communications Manual
Accessories Tag, stainless steel, 0.47 x 1.77”, one text line
Panel Mount Cable Extension 2.5 m (8.2 ft)
Cable Glands and Retaining Nuts (3-Pack)
HART Modem, USB
LUT400 Sunshield, 304 Stainless Steel
Catalog Number
7ML5050-0C_ _ _
A _ _B _ _C _ __ _ _ 1 __ _ _ 2 __ _ _ _ 1____21DA0
1DC0
-Z-C11
-Z-Y15
-Z-N07
7ML1998-5MV01
7ML1998-5XU81
7ML1998-5NE01
7ML1930-1AC
7ML1930-1GF
7ML1930-1GB
7MF4997-1DB
7ML1930-1GE
Price
$ 1936.00
135.00
306.00
0.00
0.00
0.00
0.00
17.00
0.00
66.00
25.00
18.00
43.00
48.00
43.00
31.00
48.00
57.00
20.00
603.00
235.00
Want to add a TS-3 temperature sensor? Call Lesman for pricing.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement