13s02 Flow

PricesSee Start at Page Coriolis Flow Honeywell VersaFlow Coriolis Mass Flowmeters Siemens SITRANS FC Coriolis Mass Flowmeters Call Call 64 70 Call Call Call 63 62 62 Call Call 64 66 $55.00 $87.00 $366.00 $470.00 58 56 57 59 Call 61 Call 60 $3509.00 $1936.00 72 76 Call 65 Table of Viscosities of Common Substances 489 Differential Pressure and Multivariable Mass Flow Honeywell SMV3000 Smart Mass Flowmeter Pitot Tubes, Venturi Tubes, and Bluff Body Flowmeters Orifice Plates and Orifice Flange Unions Electromagnetic Flow Honeywell VersaFlow Electromagnetic Flowmeters Siemens SITRANS FM MAGFLO Electromagnetic Flowmeters Mechanical Flow GEMS Flowmeters and Switches Kobold Flow Switches Kobold Temperature Compensated Switches and Transmitters RCM Direct Reading Flowmeters for Liquids, Air, or Gas Thermal Mass Flow Thermal Instrument Company Inline and Insertion Mass Flowmeters Turbine Flow Turbine Flowmeters for Gas and Liquid Service Ultrasonics for Pipes and Open Channel Flow Siemens F US Clamp-On Ultrasonic Flowmeters Siemens SITRANS LUT440 Open Channel Flow Monitor Vortex Flow Honeywell VersaFlow Vortex Flowmeters Reference Materials Prices in this catalog are current at the publication date, and are subject to change without notice. Due to manufacturer agreements, some products may not be available in all Lesman markets or geographic areas. Level Measurement Instruments Flow Measurement Instruments Pressure Transmitter When you need mechanical flow instruments or the most precise non-contacting flow sensors and monitoring systems, look to Lesman. Whatever the media or application, we can help you. When you’re not sure what instrument works best, you can use our collection of application datasheets. Fill in your process information, fax it to Lesman, and we’ll put your process through an engineering review with our manufacturer partners to come up with the exact instrumentation to meet your needs. Temperature Sensors and Transmitters 55 Wireless Sensing and Communications TABLE OF CONTENTS Analytical Instruments and Systems FLOW MEASUREMENT INSTRUMENTS FLOW: MECHANICAL V 01.2016 Level Measurement Instruments 56 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com [email protected] Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Flowmeters, Switches and Visual Flow Indicators PPS Polysulfone Paddle Flow Switch Flow Measurement Instruments Switch: Hermetically sealed, magnetically actuated contact; 15VA max., 0.5A max., 250V max. capacity Pressure: 145 PSI max.; 1.45 PSI max. drop Adjustment Accuracy: ±20% Switch Repeatability: ±3% Maximum Temperature: 225° F Material: NEMA 4 Polysulfone, stainless steel, ceramic magnet Connections: Thread: 1” NPT; Electric: DIN 43650 plug Pressure Transmitter Pipe Cutoff mark Bore “L” Approx. 1” 0.9” 1 1/4” 1.1” 1 1/2” 1.4” 2” 2.0” 2 1/2” 2.4” 3” 2.9” Model Selection Guide Switch Point (GPM Water) Turn-OnTurn-off 9.5 5.0 9.5 5.0 14.5 9.5 19.0 9.5 24.0 14.5 28.5 19.0 Please allow 3-4 weeks for delivery. Switch Type Catalog Number Normally Open, SPST, 15VA Max. PPS-3106 Normally Closed, SPST, 15VA Max. PPS-3105 Price $124.00 124.00 BVO Series Flowmeter/Switch for Water-Like Liquids Accuracy: ±12% full scale; Repeatability: ±2% FS Temperature: -10° to 212° F Pressure: 145 PSIG max. Flow Direction: Vertical, up Switch Characteristics: N/O switch: 240 VAC/200 VDC max. , 1.5 Amp AC/1.0 Amp DC max., 50 VA, 50 W max. power, 4-8 mm float travel hysteresis. SPDT switch: 240 VAC max. , 0.8 Amp AC max. , 30 VA max. power, 4-8 mm float travel hysteresis. Model Selection Guide Water Fitting Pressure Loss Body Range Size @ Max. Flow Brass 0.1 to 1.0 GPM 1/4” NPT 0.9 PSIG Brass 1.0 to 5.0 GPM 1/2” NPT 1.1 PSIG 304 SS 0.1 to 1.0 GPM 1/4” NPT 0.9 PSIG 304 SS 1.0 to 5.0 GPM 1/2” NPT 1.1 PSIG Optional SPDT Contact Catalog Number BVO-6102 BVO-6116 BVO-6202 BVO-6216 Suffix -U Price $283.00 283.00 541.00 541.00 0.00 Insertion Paddle/Bellows Flow Switch for Liquids Temperature Sensors and Transmitters • Position-Independent Installation • Max. Pressure 160 PSI/450 PSI, Media Temperatures to 250° F Kobold FPS paddle bellows flow switches are used wherever reliable control for minimum or maximum liquid flow is required. The flowing medium exerts a force on the paddle to actuate a micro switch. The instrument internals are separated from the process by the bellows, making the FPS an excellent choice for dirty media. Wireless Sensing and Communications Looking for a compact flow switch for non-viscous liquids? Kobold’s KAL-D is a compact all-stainless calorimetric thermal flow switch for use in small spaces and 1/4” NPT fittings. It has a switching range from 0.15 to 6.6 feet per second, works in pressures to 580 PSIG, and temperatures to 176° F. KAL-D can even be used in Clean-in-Place applications with short-term temperature limits of 250° F. KAL-D prices start at $357.00. Analytical Instruments and Systems her Searching for ot rs cato Kobold flow indi ll and switches? Ca t en Lesman for curr lit bi y. pricing and availa Model Selection Guide De-Actuating GPM H2O 2.6–8.8 3.5–12.3 4.8–16.3 9.7–25.1 11.9–28.6 18.9–47.1 50.2–122.0 100.8–234.7 158.1–360.0 319.7–729.6 Please allow 3-4 weeks for delivery. Actuating Pipe Catalog Catalog GPM H2O SizeNumber Price Number Price 4.4–9.3 1” 5.7–13.2 1.25” 7.5–17.6 1.5” 13.7–26.9 2” 17.6–30.2 2.5” FPS-5100 $277.00FPS-5200$368.00 27.3–50.2 3” (Brass) (SS) 64.7–127.7 4” 125.1–244.8 5” 189.8–385.0 6” 374.7–759.5 8” All Metal Paddle Flow Switch Flow Speed: 12 ft/sec max., adjustable flow ranges Contact: Reed switch SPST, N/O or N/C; 50VA, 50 watt, 250V, 1.5A max ratings Pressure: 1450 PSI max. Temperature: 230° F max. Materials: Housing: NEMA 4, Glass-reinforced Polyamid; Paddle, Leaf Spring, Beam: SS; Locking Plate, Screws: Brass; O-Ring: Buna-N Model Selection Guide Brass paddle flow switch, 5’ PVC cable Switch ON GPM H2O 0.9 - 1.3 1.3 - 2.1 3.0 - 4.0 3.2 - 5.0 4.9 - 8.5 9.2 - 15.0 Please allow 3-4 weeks for delivery. Switch OFF NPT Catalog GPM H2OConn. Number 0.6 - 1.2 1/4” PSR-5105 1.0 - 2.0 1/2” PSR-5115 2.2 - 3.0 3/4” PSR-5120 2.4 - 4.5 1” PSR-5125 3.8 - 7.8 1-1/4” PSR-5132 7.9 - 14.3 1-1/2” PSR-5140 Price $87.00 87.00 87.00 99.00 118.00 130.00 Call for stainless steel bodies or larger pipe sizes. u ▲ ▲ ▲ ▲ ▲ ▼ ▼ ▼ ▼ u ▼ ▲ ▼ ▲ ▼ u ▼ ▲ ▼ ▼ ▼ ▲ ▼ ▼ u ▼ u u ▼ ▼ ▼ Technology/Spec. Coriolis Flowmeter 25:1 0.1-6” 0.15% 0.1% 0 L H DP Mass Flowmeter 40:1 — 0.1% 0.1% — — H DP Orifice Plate 4:1 >1” 1% 0.1% 10-30 H L DP Pitot Tube 4:1 0.5-72” 0.75% 0.1% 10 L L DP Venturi 10:1 0.5-72” 1% 0.1% 10 M L DP Wedge 10:1 0.5-30” 3% 0.5% 12 H H Fluidic Oscillatory 15:1 1-3” 1.5% 0.2% 10 L H Magnetic Flowmeter 10:1 >0.1” 0.5% 0.2% 5 L M Paddlewheel 3:10.1-1.5”2.5% 1% 0 H L Positive Displacement 20:1 0.5-6” 1% 0.3% 0 H M Rotameter 5:10.2-3”4-8% 2% 0 ML Thermal Dispersion 100:1 0.2-72” 0.5% 0.2% 10 L H Turbine Flowmeter 10:1 >0.25” 0.5% 0.1% 10-20 H H 50:1 V-Notch 300:1— 2-5% 2% 4H 0L Vortex Flowmeter H >1” 1% 0.2% 20-30 M L Weir 300:1— 2-5% 2% 4H 0L Viscosity table for common substances, page 489. Temperature-Compensated Flow Switches and Transmitters KAL-K Flow Switch/Trend Indicator for Liquids and Oils Features • No moveable parts • Minimal pressure loss • Simple media adjustment • Temperature compensation and switch point stability • Unaffected by viscosity changes — even for the smallest flow velocities! • IP65 enclosure — insensitive to dirt • Designed for minimal pipe intrusion Specifications Measuring Range: Water: 0.05 to 2 m/sec.; Oils: 0.1 to 4 m/sec. approx. Operating Conditions: Pressure: 1450 PSIG max; Temperature: ‑10°–185° F Switching: Adjustment: By potentiometer; Selectable output: NPN or PNP, open collector; Current: 400 mA max.; Voltage: 24 VDC max.; Status indicator: Bicolored LED Power: Supply voltage: 24 VDC ±10%; Current draw: 300 mA max. Materials: Wetted parts: 304 or 316-Ti stainless steel; Housing: NEMA 4 Nylon standard, NEMA 7 Al optional Fittings: 1/2” or 3/4” NPT or 1-1/2” Tri-Clamp®. Flow Trend Indicator: Eight red LEDs Approximate Switch Point (GPM) per Pipe Diameter NominalWaterNominalWaterNominalWater IDRangeIDRangeIDRange 1/2” 0.3 – 5.0 2” 3.1 – 55 8” 50 – 900 3/4” 0.5 – 8.9 2-1/2” 4.4 – 80 10” 78 – 1400 1” 0.8 – 14 3” 7.9 – 140 12” 110 – 2000 1-1/4” 1.1 – 20 4” 12 – 220 16” 200 – 3600 1-1/2” 2.0 – 35 6” 28 – 500 20” 310 – 5600 Model Selection Guide Description Catalog Number Price KAL-K Flow Switch for Liquids, 24 VDC Power 304 SS Wetted Parts, 1/2” NPT KAL-4215 $366.00 316-Ti SS Wetted Parts, 1/2” NPT KAL-4315 414.00 316-Ti SS Wetted Parts, 3/4” NPT KAL-4320 424.00 316-Ti SS Wetted Parts, 3A Sanitary KAL-4340-S 508.00 KAL-K Flow Switch, 110 VAC Power, SPST Dry Contact Output for Liquids 304 SS Wetted Parts, 1/2” NPT KAL-4215-P03R 543.00 316-Ti SS Wetted Parts, 1/2” NPT KAL-4315-P03R 591.00 316-Ti SS Wetted Parts, 3/4” NPT KAL-4320-P03R 601.00 Options Fast Response (2.8-6 Sec.) -F 0.00 Quick Disconnect Plug (24 VDC) -M12 93.00 Pressure Transmitter u ▲ u u ▲ u ▼ ▼ u u ▼ ▲ u ▼ u ▼ Relative Cost Cryogenics u ▲ ▲ ▲ ▲ u ▼ ▼ u ▲ ▲ ▲ ▲ ▼ ▲ ▼ Permanent PSI Drop Steam ▲ u ▼ ▼ ▲ ▼ ▲ ▲ ▼ ▼ ▼ u ▼ u ▼ u Upstream Pipe Diam. Dirty Gas ▲ u ▲ u ▲ u u ▲ u u u u u u u u Repeatability (%) Clean Gas ▲ ▲ u ▼ ▲ u ▲ ▲ u ▲ u u u ▼ u ▼ Accuracy (%FS) Slurries ▲ ▲ u ▼ ▲ ▲ u ▲ ▼ ▲ ▼ u ▼ u u u Sizes Corrosives ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ Key HHigh MMedium LLow Turndown Ratio Viscous Liquid Technology Media Type Coriolis Flowmeter DP Mass Flowmeter DP Orifice Plate DP Pitot Tube DP Wedge DP Venturi Fluidic Oscillatory Magnetic Flowmeter Paddlewheel Positive Displacement Rotameter Thermal Dispersion Turbine Flowmeter V-Notch Vortex Flowmeter Weir Dirty Liquid Key ▲ Excellent: Recommended. u Fair: Works, but depends on the application. ▼ Poor: Do not use. Clean Liquid Need help figuring out which flow measurement instrumentation to use in your process? Start with the reference charts below. Find your media type to help narrow down your choices. Then, take a look at the comparative specifications in the chart at the right. Depending on your application, there may be more than one technology for you. Temperature Sensors and Transmitters What’s the Right Flow Technology for Your Process? Flow Measurement Instruments Level Measurement Instruments 57 Wireless Sensing and Communications FLOW: MECHANICAL Analytical Instruments and Systems Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 www.lesman.com [email protected] V 01.2016 Lesman Instrument Company Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 FLOW: MECHANICAL V 01.2016 Level Measurement Instruments 58 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com [email protected] Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Flowmeters and Switches RotorFlow® Flow Indicators Gems Shuttle Switches Rise to the Occasion! Flow Measurement Instruments Fluid, flowing through the switch housing, displaces a spring-loaded, calibrated shuttle, which is metered relative to a fixed orifice. When flow rate reaches the calibrated setpoint, the shuttle moves up to the stem, actuating the hermetically sealed reed switch. Flow switches respond only to flow — not pressure! RFI is Gems’RotorFlow® at its most basic form — a bright orange rotor turning with fluid flow. Either port can be used for incoming flow. Body: Polypropylene, brass, or 316 stainless steel Other wetted materials: Orange molded Nylon rotor, ceramic rotor pin, polysulfone lens, glassreinforced polypropylene low flow adapter Occasional Cleanout is a Snap! Remove the bonnet easily without disturbing the inline body. Model Selection Guide Pressure Transmitter Flow Ranges (GPM) PressureOperatingCatalog Port Size Low* High Max. Temp. ° F Number RotorFlow® RFI Flow Indicator, Polypropylene Body 0.25” 0.1 to 1.0 0.5 to 5.0 100 PSI 180° Max. 155420 0.50” 1.5 to 12.0 4.0 to 20.0 100 PSI 180° Max. 155480 RotorFlow® RFI Flow Indicator, Brass Body 0.25” 0.1 to 1.0 0.5 to 5.0 200 PSI 212° Max. 142541 0.50” 1.5 to 12.0 4.0 to 20.0 200 PSI 212° Max. 142542 0.75” — 5.0 to 30.0 200 PSI 212° Max. 180392 RotorFlow® RFI Flow Indicator, 316 Stainless Steel Body 9/16” 0.1 to 1.0 0.5 to 5.0 200 PSI 212° Max. 174596 0.50” 1.5 to 12.0 4.0 to 20.0 200 PSI 212° Max. 173138 0.75” — 5.0 to 30.0 200 PSI 212° Max. 181682 Price $55.00 55.00 145.00 145.00 145.00 185.00 185.00 215.00 Low Cost Switches for Threaded Plastic Piping FS-200 flow switches provide accurate flow detection with 1% repeatability. Bronze and Teflon® construction delivers long life in water and oil, and fluid temperatures to 300° F. Setpoints are calibrated using water at 70° F on increasing flow with unit in a horizontal position (lead wires up). Operating Pressure: 400 PSIG @ 100° F Operating Temperature: -20° to 200° F Switch: SPDT, 20 vA Temperature Sensors and Transmitters Gems FS-500 offers low cost flow monitoring with a variety of switch actuation points and low pressure drop. All wetted parts are polypropylene or stainless steel, making this switch ideal for a wide range of chemical and temperature requirements. The materials are also NSF or FDA approved for potable water treatment applications including chlorinators, purifiers and heaters. Wireless Sensing and Communications Wetted Materials: Housing, Bonnet, Shuttle, Shuttle Cap: Polypropylene O-Ring: Viton® or Buna N Spring: 316 Stainless Steel Retaining Clip: PH 15-7 Mo Stainless Steel Maximum Operating Temp.: 0° to 212° F Setpoint Accuracy: ±20% Switch: SPST, N.O. Pilot Duty 20 VA, 120-240 VAC or VDC Inlet/Outlet Ports: 3/4” Female NPT Rugged Flow Switches Deliver Accurate, Reliable Service Model Selection Guide Port Size Model Selection Guide FS-500 Flow Switch Catalog Setpoint Number Price 0.25 170231 $71.00 0.5 170232 71.00 1 170233 71.00 2 175117 71.00 2.5 170234 71.00 5 170235 71.00 1” NPT 1-1/4” NPT General Purpose Switch for Plastic Piping Analytical Instruments and Systems These Gems FS-400P switches have a noncorrosive, clear PVC housing for broad chemical compatibility, and are ideal for flow/no-flow detection. 1-1/2” NPT Materials: PVC, Epoxy, and Buna-N Switch: SPST, 20 VA, N.O. at no-flow Model Selection Guide Connect Size Actuation on Increasing Flow Pressure Max. Operating Temp (° F) 1/2” NPT* 0.5 GPM ± 20% 120 PSIG 120° * 3/4” IPS model with 1/2 NPT port installed. Catalog Number Price 135805 $81.00 Flow Setting (GPM) 0.5 1 2 3 4 5 6 8 1 2 4 6 8 10 12 16 20 1.5 3 5 7.5 10 15 20 30 Bronze Body Catalog Number Price 27051 $191.00 27052 191.00 27053 191.00 27054 191.00 27055 191.00 27056 191.00 27057 191.00 27058 191.00 27067 365.00 27068 365.00 27069 365.00 27070 365.00 27071 365.00 27072 365.00 27073 365.00 27074 365.00 27075 365.00 27085 447.00 27086 447.00 27087 447.00 27088 447.00 27089 447.00 27090 447.00 27081 447.00 27092 447.00 Stainless Steel Body Catalog Number Price 27059 $569.00 27060 569.00 27061 569.00 27062 569.00 27063 569.00 27064 569.00 27065 569.00 27066 569.00 27076 838.00 27077 838.00 27078 838.00 27079 838.00 27080 838.00 27081 447.00 27082 838.00 27083 838.00 27084 838.00 27093 881.00 27094 881.00 27095 881.00 27096 881.00 27097 881.00 27098 881.00 27099 881.00 27100 881.00 Looking for other Gems flow switches or indicators? Need a different material or port size? Call Lesman! Specifications RCM Series 8000 Flo-Gage® is designed for larger pipe sizes and mounts between adjoining flanges (ANSI 150#, 300#, DIN PN10, PN16, JIS, AS). Install the Flo-Gage just as you would install an orifice plate, with flat gaskets and bolts (order separately). Accuracy: ±3% full scale Range: Flow rates to 500 GPM or 4000 SCFM; Rangeability: 6:1 Mount: Horizontal (standard), flow to the right Temperature: 212° F max. , 350° F max. optional Pressure: 180 PSIG max., 400 PSIG max. optional Construction: Diecast aluminum housing, glass or polycarbonate crystal, bronze body, bronze gear movement, Buna-N seals. Other materials available on request Options: High/Low alarm relays, 4-20 mA, 0-1000 Hz output, digital display for flow rate/ totalization Specifications Accuracy: ±3% full scale; Repeatability: 1% full scale Range: Flow rates to 3000 GPM liquid or 20000 SCFM gas; Rangeability: 6:1 Mount: Horizontal (standard), flow to the right Operating Conditions: Temperature: 212° F max., 350° F opt.; Pressure: 180 PSIG max., 400 PSIG opt. Construction: Bronze body, movement, ABS housing and crystal, Buna-N seal. Call for other materials Options: Relay: High/Low alarms; Output: 4-20 mA, 0-1000 Hz frequency. Optional Digital Display. Shown with optional 4-20 mA loop-powered two-wire indicator. Displays 4-1/2 digits for flow rate, 8 digits for totalization. Includes scaled, open collector output for remote totalizer, and square root extraction for use with W3 solid- state strain gauge. Call for pricing. Model Selection Guide Model Selection Guide for Liquids Standard mounting is horizontal, (R) designates flow going to the right. For other configurations, call Lesman. When ordering, please specify media, pressure, and temperature. Media Type NPT Connection 0.5 - 6 GPH 1⁄2” 3.0 - 20 GPH 1⁄2” 5.0 - 60 GPH 1⁄2” 15 - 100 GPH 1⁄2” 0.5 - 4.0 GPM 1⁄4” 0.5 - 4.0 GPM 1⁄2” 0.5 - 6.0 GPM 1⁄2” For 1.5 - 10 GPM 1⁄2” Liquid 0.5 - 6.0 GPM 3⁄4” 1.5 - 10 GPM 3⁄4” 3.0 - 20 GPM 3⁄4” 3.0 - 20 GPM 1” 5.0 - 40 GPM 1” 5.0 - 40 GPM 1-1⁄2” 15 - 100 GPM 1-1⁄2” 15 - 100 GPM 2” 5.0 - 40 SCFH 1⁄2” 15 - 100 SCFH 1⁄2” 30 - 200 SCFH 1⁄2” 50 - 400 SCFH 1⁄2” 1.5 - 10 SCFM 1⁄4” 4.0 - 30 SCFM 1⁄4” 1.5 - 10 SCFM 1⁄2” 4.0 - 30 SCFM 1⁄2” For Air 5.0 - 60 SCFM 1⁄2” or Gas 5.0 - 60 SCFM 3⁄4” 15 - 100 SCFM 3⁄4” 30 - 200 SCFM 3⁄4” 30 - 200 SCFM 1” 50 - 600 SCFM 1-1⁄2” 50 - 600 SCFM 2” 150 - 1000 SCFM 2” 400 - 3000 SCFM 3” Options: Add as suffix to catalog number Calibrate for specific gravity other than water Hi/Lo alarm setpoint relays (Req. 24 VDC power) NEMA 4X Gasketed Meter Case Flow Rate Intrinsically safe switches available. Call for pricing. Catalog Number 1⁄2-71-R-06-ES 1⁄2-71-R-20-ES 1⁄2-71-R-60-ES 1⁄2-71-R-100-ES 1⁄4-71-R-04 1⁄2-71-R-04 1⁄2-71-R-06 1⁄2-71-R-10 3⁄4-71-R-06 3⁄4-71-R-10 3⁄4-71-R-20 1-71-R-20 1-71-R-40 1.5-71-R-40 1.5-71-R-100 2-71-R-100 1⁄2-71-R-40-IES 1⁄2-71-R-100-IES 1⁄2-71-R-200-IES 1⁄2-71-R-400-IES 1⁄4-71-R-10-I 1⁄4-71-R-30-I 1⁄2-71-R-10-I 1⁄2-71-R-30-I 1⁄2-71-R-60-I 3⁄4-71-R-60-I 3⁄4-71-R-100-I 3⁄4-71-R-200-I 1-71-R-200-I 1.5-71-R-600-I 2-71-R-600-I 2-71-R-1000-I 3-71-R-3000-I -C -X -D Price $ 580.00 580.00 580.00 580.00 470.00 470.00 470.00 470.00 530.00 530.00 530.00 555.00 555.00 630.00 630.00 730.00 665.00 665.00 665.00 665.00 555.00 555.00 555.00 555.00 555.00 615.00 615.00 615.00 640.00 715.00 815.00 815.00 1000.00 85.00 350.00 50.00 Media Type Range Fittings GPM Liquid Flange Size 0.3 – 2.0 1⁄2” 0.4 – 3.0 1⁄2” 0.5 – 4.0 1⁄2” 0.5 – 6.0 1⁄2” 1.5 – 10 1⁄2” 0.5 – 6.0 3⁄4” 1.5 – 10 3⁄4” 2.0 – 15 3⁄4” 3.0 – 20 3⁄4” 2.0 – 15 1” 3.0 – 20 1” 5.0 – 40 1” 4.0 – 30 1-1⁄2” 5.0 – 40 1-1⁄2” 5.0 – 60 1-1⁄2” 15 – 100 1-1⁄2” 5.0 – 40 2” 5.0 – 60 2” For 15 – 100 2” Liquid 20 – 150 2” 30 – 200 2” 30 – 200 3” 40 – 300 3” 50 – 400 3” 60 – 500 3” 40 – 300 4” 50 – 400 4” 50 – 600 4” 100 – 800 4” 50 – 600 6” 100 – 800 6” 150 – 1000 6” 300 – 2000 6” 50 – 600 8” 150 – 1000 8” 300 – 2000 8” 400 – 3000 8” Options: Add as suffix to catalog number Hi/Low alarm setpoint relays (Req 24 VDC power) 4-20 mA loop-powered output 0-100 Hz output For gas applications Catalog Number 1⁄2-81-R-02 1⁄2-81-R-03 1⁄2-81-R-04 1⁄2-81-R-06 1⁄2-81-R-10 3⁄4-81-R-06 3⁄4-81-R-10 3⁄4-81-R-15 3⁄4-81-R-20 1-81-R-15 1-81-R-20 1-81-R-40 1.5-81-R-30 1.5-81-R-40 1.5-81-R-60 1.5-81-R-100 2-81-R-40 2-81-R-60 2-81-R-100 2-81-R-150 2-81-R-200 3-81-R-200 3-81-R-300 3-81-R-400 3-81-R-500 4-81-R-300 4-81-R-400 4-81-R-600 4-81-R-800 6-81-R-600 6-81-R-800 6-81-R-1000 6-81-R-2000 8-81-R-600 8-81-R-1000 8-81-R-2000 8-81-R-3000 Price $470.00 470.00 470.00 470.00 470.00 530.00 530.00 530.00 530.00 555.00 555.00 555.00 630.00 630.00 630.00 630.00 730.00 730.00 730.00 730.00 730.00 915.00 915.00 915.00 915.00 995.00 995.00 995.00 995.00 1200.00 1200.00 1200.00 1200.00 1650.00 1650.00 1650.00 1650.00 –X –W –Y –I 350.00 600.00 600.00 85.00 Level Measurement Instruments Direct Reading Flowmeters Flow Measurement Instruments 59 Pressure Transmitter FLOW: MECHANICAL Temperature Sensors and Transmitters Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Wireless Sensing and Communications www.lesman.com [email protected] Analytical Instruments and Systems Lesman Instrument Company V 01.2016 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 FLOW: TURBINE Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 V 01.2016 Level Measurement Instruments 60 Lesman Instrument Company www.lesman.com [email protected] Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Turbine Flowmeters for Gas and Liquid Service Low Cost Industrial Flowmeters for Liquid Measurement Flow Measurement Instruments Features • Simple construction allows for rugged and dependable service at low cost • Off-the-shelf delivery; Companion electronics available in 10 to 15 days • Outstanding accuracy at low cost, without compromise in design Pressure Transmitter For Gas Service Specifications Flowmeter Size: 1/4” to 3” diameter Repeatable Flow Range: 0.25 to 800 GPM Accuracy and Linearity: ±1.0% reading or better Repeatability: ±0.1% reading or better Temperature: ‑450° to 350° F with UB bearing; ‑450° to 450° F with C bearing Signal Output: 10 MVRMS or greater with 10KΩ load at minimum flow rate Materials: 316 stainless steel; Rotor: 17.4 PH stainless steel; Bearings: 440C stainless steel or hard carbon composite For Liquid Service Features • Radio frequency (RF or MCP) pickup coils provide wide rangeability • Four blade angles available (15°, 20°, 25°, and 30°) per flowmeter size for optimum performance • Shielded, self-lubricating ball bearings provide extended life Temperature Sensors and Transmitters The design of these turbine gas meters minimizes drag effects, which results in wide ranges and long-term accuracy. All meters are equipped with special self-lubricating, long-life ball bearings and low-drag, magnetic, modulated carrier or pickups. Gas turbine flowmeters are available with standard flanged, 37° flared, NPT, or special end fittings. Hazardous and weatherproof coil enclosures are available. Specifications Wireless Sensing and Communications Flowmeter Size: 1/2” x 1/4” to 12” diameter Linear Range: 0.15 to 12,000 ACFM Overrange: 150% of maximum flow (intermittently) Linearity: ±1% reading Repeatability: ±0.25% over usable range Temperature: ‑450° to 350° F, to 400° F intermittent heat Bearings: Ceramic hybrid ball bearings only Materials: 316 SS. Other materials available for corrosive applications. End Fittings: MS flared and flanged styles recommended Features • Threaded or flanged process connections • Outstanding accuracy • Provides wide flow ranges (10:1 to 100:1 turndown ranges available) • Wide variety of process connections and construction materials • Operates over wide range of temperatures and pressures Specifications Size: 1/4” to 12” diameter Linear Range: 0.35 to 12,000 GPM Overrange: 150% of maximum flow (intermittently) Linearity: ±0.5% reading (±0.25% typical) over tabulated linear flow range Repeatability: ±0.1% (±0.05% typical) over tabulated repeatable range Pressure Drop: 4 to 5 PSI at maximum linear flow rate at one CSTK Turndown: 10:1 to 100:1 Temperature: ‑450° to 450° F; High temperature option to 850° F End Fittings: NPT, MS flared, and flanged; Others available Bearings: Ceramic hybrid ball bearings; Sleeve bearings in tungsten carbide; Teflon and hard carbon composite available Materials: 316 SS. Other materials available for corrosive applications. Analytical Instruments and Systems Need help with turbine flowmeters? Fill out the application datasheet from Lesman.com/datasheets/ and fax it back to Lesman. Great for ne mass flow ha et m applications! Model 600-9 Inline Design The Model 600-9 thermal mass flowmeter provides reliable, accurate flow measurement with no obstructions to the actual flow path. It handles liquids, slurries, gases, and homogeneous solids through a wide range of flow rate, temperature, pressure, viscosity, abrasiveness, or chemical compositions. The 600-9’s sensor is built into the meter’s outer surface and is completely protected from adverse process conditions. The spool matches the actual flow pipe in dimensions and construction material, and is impervious to fluid, as is the rest of the line. System electronics include the flow analyzer, temperature compensator, and signal conditioner to provide a linear output directly proportional to mass flow. An optional output provides continuous temperature measurement. ebsite for Call or visit our w ion. at more inform Specifications Accuracy: Better of ±1% full scale or 4% reading; Repeatability: Better than 0.2% reading; Linearity: 0.5% Temperature Limits: ‑20° to 350° F; Calibrated Temperature Range: ±50° F Pressure Limits: 0 to 1200 PSI (Max. pressure ratings depend on pipe size.) Pressure Range: Liquids: Unlimited; Gases: 20 atmospheres Response Time: Liquids: Less than 1/2 second; Gases: 1 to 2 seconds typical, 4 to 8 seconds worst case Pressure Drop: Negligible, completely unobstructed flow path Viscosity: Up to 5000 cps Flow Rate: (Volumetric flow units for gases should be expressed in standard or normal units.) Liquids: 0.003 grams/min minimum full scale; Gases: 2 SLPM minimum full scale. Maximum determined by pipe capacity. Flow Range: 10:1 (100:1, 1000:1, multiple ranges available) Flow Element: Meets NEMA 4, 7, and 9 explosion-proof requirements. Electrical connection: 1/2”; Construction: 316 SS standard (316 SS, 304 SS Hastelloy®, Monel, Inconel®, tantalum, titanium, gold, platinum, nickel, Carpenter 20®, glass); Connections: Flanged, Swagelok®, NPT, VCR, VCO, Tri-Clamp, concentric reducer, flared, sanitary, high pressure fittings, wafer, barbed, welded, others; Coatings: Teflon®, tungsten, carbide, HMF® Remote Flow Transmitter: Model 9200: Panel or wall mount; Model 926A: NEMA 4 JIC type; Model 926B: NEMA 4, 7, and 9 explosion-proof. Others available upon request Outputs: Standard 4-20 mA DC isolated/1000Ω max. load (0-10V DC, 0‑5VDC, 10‑50 mA DC, pulse output) Options: Digital flow indication, 8-digit LED totalizer, batch counter, hi/lo alarm setpoints, bidirectional flow, temperature output, multiple ranges Need help with thermal dispersion mass flowmeters? Fill out the Thermal Instruments application datasheet from www.Lesman.com/datasheets and fax it back to Lesman. Model 62-9 Insertion Design The Thermal Model 62-9 flow probe is designed to measure the flow rates of gases, liquids, or slurries in stacks, irregularly shaped lines, and process ducts. Unlike other probe flowmeters, the 62-9 has no apertures that can become clogged with particles or distorted by heat. The sensing element is located on the probe’s inside leading edge and has no contact with the flow stream. The 62-9 can be made of pipe or tubing using any metal compatible with the flow stream of a given application. It can also be built with extra length, so it can be inserted through a gate valve and packing gland. This will allow easy insertion and removal while the pipe is in use. The thermal probe’s electrical connections can be made either in a gasketed-type conduit or an explosion-proof conduit. For applications over 350° F, the sensors are made of platinum embedded in a ceramic matrix, securely bonded to the pipe’s inside diameter. An additional temperature sensor can also be installed, as well as independent circuitry to provide fluid temperature readout signals. Specifications Flow Range: 10:1 (100:1, 1000:1, multiple ranges available) Flow Limits: (Volumetric flow units for gases should be expressed in standard or normal units.) Liquids: 0.02 FPS to 20 FPS FS; Gases: 40 SFPM to 15000 SFPM FS. Maximum determined by pipe capacity. Accuracy: Better of ±0.5% full scale or 2% reading. Calibrated by weight or volume (0.5% FS). Repeatability: Better than 0.2% reading; Linearity: 0.5% Temperature Limits: ‑20° to 1100° F; Calibrated Temperature Range: ±50° F Pressure Limits: 0 to 60000 depending on size PSI Response Time: Liquids: Less than 1/2 second; Gases: 1 to 2 seconds typical, 4 to 8 seconds worst case Viscosity: Up to 5000 cps Flow Element: Meets NEMA 4, 7, and 9 explosion-proof standards. Construction: 316 SS standard; Connections: Flanged, Swagelok®, NPT sanitary Tri-Clamp, hot tapping, retractable, saddle mount; Coatings: Teflon®, HMF®, Nedox® Remote Flow Transmitter: Model 9200: Panel mount or NEMA 4 box; Model 926A: NEMA 4 JIC; Model 926B: NEMA 4, 7, and 9 explosion- proof. Pipe Size: 1” minimum Outputs: Standard 4-20 mA DC isolated/1000Ω max. load (0-10V DC, 0‑5VDC, 10‑50 mA DC, pulse output) Options: Digital flow indication, 8-digit LED totalizer, batch counter, hi/lo alarm setpoints, bidirectional flow, temperature output, multiple ranges, flow profile, multipoint, averaging Level Measurement Instruments Thermal Dispersion Mass Flowmeters Flow Measurement Instruments 61 Pressure Transmitter FLOW: THERMAL Temperature Sensors and Transmitters Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Wireless Sensing and Communications www.lesman.com [email protected] Analytical Instruments and Systems Lesman Instrument Company V 01.2016 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Level Measurement Instruments Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 V 01.2016 FLOW ELEMENTS 62 Lesman Instrument Company www.lesman.com [email protected] Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Orifice Plates, Flange Unions, and Pitot Tubes Please allow 10 days for delivery. Flow Measurement Instruments If you need your order faster, just let us know. In most cases, we can arrange for overnight or second-day shipping. Or, we’ll work with you to arrange delivery by local messenger service. Same-day shipping is available for a small premium. Paddle-Type Orifice Plates Build a Paddle Type Orifice Plate Part Number Pressure Transmitter Pipe Size Flange Rating Full Face Flange? Plate Thickness ____ __ __ 01 See Chart Below See Chart Below Yes=FF No= Blank 1/8” Plate Material Bore Style __ C 304SS=04 Concen316SS=16 tric Weep Hole? _ Drain or Vent=W No=Blank What bore size do you need? _________________________________________ Not sure what bore size you need? We can calculate it for you. ($35 flat fee.) If you need a drain or vent, specify Pipe Schedule or ID: ____________________ Raised Face Weld Neck Orifice Flange Unions Temperature Sensors and Transmitters All raised face flange unions are made of A105 carbon steel and include nuts, bolts, and 1/16” gasket. Build a Raised Face Weld Neck Orifice Flange Part Number Wireless Sensing and Communications Analytical Instruments and Systems Pipe Size Flange Rating Material Grade Face Style Flange Style Pipe Schedule Hardware ____ __ CS R WN 40 C See Chart Below 300#=03 600#=06 A105 Carbon Steel Raised Face Weld Neck Schedule 40 Complete with Nuts, Bolts, and Gaskets Code 0300 0400 0500 0600 0800 1000 1200 Pipe Size 14” 16” 18” 20” 24” 30” 36” Code 1400 1600 1800 2000 2400 3000 3600 Code 03 Flange 600# Code 06 (No 150#) Pipe Size and Flange Rating Options (1) Select Your Pipe Size Pipe Size 0.5” 0.75” 1” 1.25” 1.5” 2” 2.5” Code 0050 0750 0100 0125 0150 0200 0250 Pipe Size 3” 4” 5” 6” 8” 10” 12” Other Flow Elements Available from Lesman Pitot Tubes Inline sensors for measuring flow in pipe lines from 1/2”to 3”nominal size. Uses two averaging probes of equal area to sense differential pressure loss while providing minimum permanent pressure loss. Probe or insert-type sensors for measuring flow in pipelines from 3” to 24”, using equal area double averaging pitot tubes for low permanent pressure loss. Venturi Flow Elements Herschel Type Classic style Venturi tube designed in accordance with ASME or ISO standards and offers a constant degree of accuracy and high repeatability. Venturi-Nozzle Type Design uses the classical ASME and ISO standards for highest accuracy, predictability, and repeatability. Flow conditioning generated by unique hydraulic shape provides a stable signal in a wide range of flows. Low-Loss Design (Short-Form) Design provides proven field performance in a variety of applications. Low installation cost due to short laying length, reduced operating costs, and a wide range of sizes and materials add up to the right choice for your needs. Bluff Body Differential Pressure Flowmeters The bluff body flowmeter is the only differential pressure flowmeter that fully conditions the flow prior to measurement. It’s ideal for lines with limited straight piping. This flowmeter provides repeatable accuracy up to ±0.5% flow rate, even under the most difficult flow conditions, and over a wide range of Reynolds numbers. Because this meter can accurately measure disturbed flow, it doesn’t require the upstream or downstream straight pipe runs of many other flowmeters; so, it can fit where other flowmeters can’t because of limited space or weight requirements.. Left: Precision flow tube, Right: Insertion weld-on saddle. (2) Specify the Flange Rating Flange 150# Code 01 Flange 300# Call, fax, or e-mail your completed part number to Lesman for a quote on price and delivery. Prices are valid for two weeks from the quote date. Need help finding the flow element you need? Fill out the application datasheet from www.Lesman.com/datasheets and send it to Lesman for engineering review. www.lesman.com [email protected] Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 MULTIVARIABLE TRANSMITTER 63 Smart Multivariable Flowmeter for Gas and Steam Looking for differential pressure smart transmitters for your flow applications? See pages 86 to 89. SMV3000 Level Measurement Instruments Lesman Instrument Company V 01.2016 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Ordering Instructions Make one selection from each table section below. Check any restriction letters or notes (E.g.: N3) to be sure the unit is available. A finished catalog number looks like this: SMA110-E1A-00000-S2,MB,F1C3-XXXX Model Selection Guide Turndown Ratio: 150:1 Accuracy: Analog Mode: Greater of ±0.10% calibrated span or URV; Digital Mode: Lesser of ±0.075% calibrated span or ±0.15% reading. Temperature Measurement Range (Pt100Ω RTD): -328° to 1562° F operating; 1.08° F accuracy Adjustment Range: Limit to zero/span within range. Accuracy (Reference): Analog Mode: Digital accuracy + Output D/A accuracy; Digital Mode: Digital accuracy; (Output D/A): ±0.025% of span Thermocouple Burnout: User-selectable detection: ON = up- or downscale failsafe action, critical status message for any open lead. View full specifications online at Lesman.com Catalog AvailNumberability Price • • • ••• ••• j j j 1C 24.00 85.00 22.00 211.00 • • • 0.00 • • • 0.00 b 1J Restrictions b Select only one option from this group. j Available only on units with CTFE fill ( _ 2 _ in Fill Fluid). t Available only with 1/2” NPT adapter flange (Options S2, T2, or V2). v Includes side vent drain at no added cost. w Available only with 316SS process heads. Not available with side vent/drain (SV). 96 See pagewell y e for Hon 00 SCT30 smart n tio configurait. lk o o t Add a three-valve manifold to your transmitter! See page 345. For 100Ω RTDs, see page 98. Temperature Sensors and Transmitters TG MC WP 0X Wireless Sensing and Communications A _ _ • • • 0.00 E _ _ • • • 77.00 J _ _ v v 1608.00 L _ _ v 821.00 _ 1 _ • • • 0.00 _ 2 _ • • • 57.00 _ _ A • • • 0.00 _ _ H t t t 0.00 00000 ••• 0.00 00 ••• 0.00 ME • • • 170.00 VT • • • 0.00 MB • • • 20.00 SB b • • • 75.00 FB • • • 20.00 LP • • • 68.00 Pressure Transmitter SMA110 ↓ $2939.00 SMA125 ↓ 2873.00 SMG170 ↓2938.00 Analytical Instruments and Systems Description Differential Pressure Range Pressure Range 0”-1” / 25” H2O 0-100 PSIA Features 0"-1" / 400" H2O 0-750 PSIA • Single sensor measures absolute and differential pressure this 0"-1" 400"ed H2O 0-3000 PSIG ti/ nu scon from one pipe intrusion Honeywell has di sman Process Vent/DrainBarrier r fo ll Le Head Valve, Plug Diaphragm t. Plea • Calculations for volumetric or mass flow rate, or se ca uclinear prod t, emenSteel ac pl re Material Carbon 316 SS 316L SS s it square root output conformity for differential pressure, on n informatio 316 316 SS 316L SS . SS and engineering units display for PV, flow rates martLine SMV800 Hastelloy C Hastelloy C Hastelloy C the S • Improves efficiency in commissioning, start-up, and on Monel Monel Monel going maintenance through local and remote interface Fill Fluid Silicone CTFE with SmartLine Configuration Toolkit and host system Process 1/4" NPT Condensed Specifications Head 1/2" NPT with Adapter (1/4" NPT Head) No Selection Temperature: -40° to 200° F; Meter Body : -40° to 257° F None Pressure: 1” H2O Abs for 2 hrs @ 158° F min.; Overpressure: 3000 PSI Analog Meter (0-100 Even, 0-10 Sq. Root.) Two-Wire Output: 4–20 mA or digital (DE protocol) Viton Head Gaskets (1/2" Gaskets Special) RFI Protection (Std.): Negligible effect (20–1000 MHz @ 30V/meter) Mounting Bracket — Carbon Steel Mounting Bracket — Stainless Steel Materials: Process Interface: 316L SS, Hastelloy C-276, Monel, Tantalum Flat Mounting Bracket — Carbon Steel diaphragms; 316 SS, Carbon Steel, Monel, Hastelloy process heads; Lightning Protection Teflon, Viton head gaskets; Carbon Steel, A286 SS (NACE) bolting; MountStainless Steel Customer Wired-On Tag ing Bracket: Carbon Steel; Electronics Housing: Low Copper Aluminum (4 Lines, 28 Char/Line, User-Supplied Info.) Hazardous Conditions: Housing meets NEMA 4 (watertight) and NEMA Multivariable Transmitter Configuration 7 (explosion-proof ); FM, CSA, ATEX approval available. Write Protection Differential Pressure Measurement Clean for Oxygen/Chlorine Service, Certificate Approval Type Location/Class Upper Range Limit (URL): 400” H2O (1000 mbar) Explosion Proof Cl I, Div 1, Gr A-D Turndown Ratio: ±400:1 Dust Ignition Proof Cl II, III, Div 1, Gr E-G Minimum Span: 20” H2O square root; 1” H2O linear Suitable for Cl III, Div 1 Zero Elevation/Suppression: No limit (min. span) within ±100% URL. Non-Incendive Cl I, Div 2, Gr A-D FM Intrinsically Safe Cl I, II, III, Div 1, Gr A-G Accuracy: Analog Mode: Greater of ±0.10% calibrated span or URV; Digital Mode: Lesser of ±0.075% calibrated span or ±0.15% reading. Explosion Proof Cl I, Div 1, Gr B-D Dust Ignition Proof Cl II, III, Div 1, Gr E-G Absolute Pressure Measurement Suitable for Cl III, Div 1 Non-Incendive Cl I, Div 2, Gr A-D Upper Range Limit (URL): 750 PSIA; Minimum Span: 5 PSIA Intrinsically Safe Cl I, II, III, Div 1, Gr A-G Flow Measurement Instruments Ranges Differential Pressure: ±400” H2O Absolute Pressure: 0 to 750 PSIA Process Temperature: -328° to 842° F FLOWMETER SYSTEMS V 01.2016 Level Measurement Instruments 64 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com [email protected] Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Honeywell VersaFlow — Flowmeters for Any Application Flow Measurement Instruments Pressure Transmitter Electromagnetic Flowmeter Coriolis Mass Flowmeter • • • • • Innovative twin measuring tube sensors with optimized flow divider for minimal pressure loss • For applications up to 266° F (130° C) • Measures from 0.3 to 430,000 kg/h flow • Pressure-resistant jacket to 1450 PSI (100 bar) • Excellent zero stability • Available with hygienic process connections for food and pharmaceutical applications • Rapid signal processing, even with product and temperature changes or sudden changes in density • Modular electronics concept and data redundancy – sensor and plug-and-play electronics are easy to replace • Viscous or shear-sensitive products • Products requiring low flow velocities, products with entrained solids or gas, or products in homogeneous mixtures • Flow and purity measurement, density, temperature, and concentration measurement • • • Temperature Sensors and Transmitters • • • • • Wireless Sensing and Communications • Conductivity down to 1 uS/cm Temperatures to 356° F (180° C) Available sizes 0.1” to 80” (DN 2.5-3000) Stainless steel flow tube spool with carbon steel or stainless steel flanges Standard liner materials: PTFE, PFA, ETFE, hard rubber, and polyurethane Electrodes available in 316 stainless steel, Hastelloy C, platinum, titanium, tantalum, carbon, PTFE, and Cermet Signal converters available in wall mount, rack mount, compact, and field-ready housings Signal converter offers local display, infrared interface, HART communications, four isolated outputs Diagnostics to standards better than requested by NAMUR 2650: 100% flow sensor and converter check, 100% process/ application check, 100% linearity/calibration check Accuracy to ±0.15% measured value Suitable for all conductive applications Measures flow in any application, from clean liquids to slurries and pastes with high solids content Abrasion-, chemical-, and vacuum-resistant Analytical Instruments and Systems VersaFlow magnetic flowmeter is suitable for a variety of measuring tasks and applications, including rapidly changing media, pH jumps, large amounts of solids, or pulsating flow. It delivers significant cost savings during planning, procurement, installation, and training. VersaFlow is wired exactly like a traditional magmeter, but no earth connection to the liquid is required. This reduces the high costs involved with purchasing exotic metal grounding rings or electrodes. A new virtual reference grounding eliminates the need for grounding electrodes or rings, reducing installation costs and potential leak points. It provides complete isolation with opto-couplers of the flow converter’s input amplifier and coil power circuits. The measurement circuit “floats” at liquid’s potential, sensing only the induced voltage caused by the velocity of the conductive liquid flowing through the sensor. A calibrated flow simulator is available for magmeters to troubleshoot converter and other system indicators and controls. It replaces the flow sensor in the system and simulates no-flow and up to five flow rates to troubleshoot flow output issues. Visit www.Lesman.com for complete specifications. VersaFlow coriolis measures mass flow, density, volume, temperature, mass, or volume concentration and solids content with a single device. It’s the only Coriolis sensor for mass flow in its class with secondary pressure containment standard. It offers a high degree of accuracy, even for problematic applications. All meters consist of a sensor and a converter. The converter is mounted integral to the sensor or remotely via a field-mount kit, a wall-mount housing, or a 19” rack-mount module. Condensed Specifications Flow Rate: 0–240 to 0–15800 lbs/min, depending on sensor model Accuracy: Liquid: ±0.15% actual measured flow rate; Gas: ±0.5% actual measured flow rate Density Measuring Range: 25-155 Lbs/Ft3 (400-2500 Kg/m3) Temperature Measuring Range: -40° to 302° F (-40° to 150° C); Accuracy: ±1.8° F (1° C) Materials: Sensors available in Stainless steel, Titanium, Hastelloy, or Tantalum, aluminum or stainless steel housings Approvals: FM, CSA, ATEX, 3A (depending on model selected) Visit www.Lesman.com for complete specifications. See our viscosity table for common substances, page 489. www.lesman.com [email protected] Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 FLOWMETER SYSTEMS 65 VersaFlow Vortex for Monitoring Steam Production and Transfer Level Measurement Instruments Lesman Instrument Company V 01.2016 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Condensed Specifications Measuring Principle: Karman vortex street Measured Value: Primary: Number of separated vortices; Secondary: Operating and standard volumetric flow or mass flow Accuracy: Reynolds numbers (Re)≥20000: ±0.75% for liquids, Re≥20000: ±1% for gases or vapors; 10000<Re<20000: ±2% for liquids, gases, or vapors; Repeatability: ±0.1%; Stability: ±0.1% over 1 year Process Medium Viscosity: <10 cP Outputs: Current: 4-20 mA; Pulse: Pulse frequency 0.5 Hz; Communications: HART® protocol Approvals: FM: Class 1, Div 1; ATEX: II 2G EEx d ia [ia] IIC T6 Visit www.Lesman.com for complete specifications. To select a Honeywell VersaFlow system for your application, complete the datasheet from www.Lesman.com/datasheets/ and send it to Lesman for engineering review. Size of Leak 1/8” 3/16” 1/4” 5/16” 3/8” 7/16” 1/2” Steam Loss per Month (Lbs) 52,500 117,000 210,00 325,000 470,000 637,000 835,000 Total Cost per Month $262.50 $585.00 $1,050.00 $1,625.00 $2,350.00 $3,185.00 $4,175.00 Annual Cost $3,150.00 $7,020.00 $12,600.00 $19,500.00 $28,200.00 $38,220.00 $50,100.00 One pound of 100 PSI steam contains about 1,200 BTUs. 1 MCF of natural gas contains 1 million BTUs. If the steam is produced at 85% efficiency, the input energy is 1411 BTUs per pound. (1200/0.85=1411) So, 1000 pounds of steam requires 1.4 million BTUs to produce it. The cost to produce 1000 pounds of steam from natural gas is 1.4 x cost/MCF. So, when natural gas costs $7/MCF, the cost of 1000 pounds of steam is $9.80. Further, by using the vortex meter’s local display or the HART® protocol, you can track temperature and see any extraordinary heat loss from where you measured at the boiler. Heat loss means energy costs, so tracking this variable can be critical. Honeywell’s VersaFlow vortex meter is the only meter of its type that offers integral temperature compensation standard, and integral pressure compensation as an option. These features improve accuracy and significantly reduce energy costs. VersaFlow can also be used for: • Burner consumption measurement • Controlling compressor capacity, consumption measurement in compressed air networks • SIP and CIP processes in the food, beverage, and pharmaceutical industries • Measuring industrial gases (natural gas, oxygen, nitrogen, hydrogen, and argon) • Conductive and non-conductive liquids Pressure Transmitter Temperature Sensors and Transmitters For superheated and saturated steam measurement, steam boiler monitoring, compressor output monitoring, measuring consumption in compressed air systems, measuring consumption of industrial gases, SIP and CIP processes in the food, beverage, and pharmaceutical industries VersaFlow 100 is the only vortex flowmeter with integrated pressure and temperature compensation in two-wire technology, providing maximum performance at the lowest installed cost. VersaFlow provides reliable measurement of operating, standard volumetric, and mass flow of conductive and non-conductive liquids, gases, and vapors, even with fluctuating pressures and temperatures. Cost of steam leaks, given 100 PSI steam flow, at $5.00 per 1000 pounds. Wireless Sensing and Communications • Works with conductive or non-conductive liquids, industrial compressed gases • Sensors with 0.5” to 12” flanges or 0.5” to 4” sandwich sizes • Two-wire device with integrated pressure and temperature compensation, plus compensation for saturated steam • Non-wearing, fully welded stainless steel construction with high corrosion, pressure, and temperature resistance • Optimal process reliability: Intelligent stable readings, free of external signal processing • Maintenance-free sensor design • Current, pulse, and HART communications outputs Analytical Instruments and Systems Vortex Flowmeter There are two costs associated with the production of steam. The first is the gas feed to the boiler. The other is in monitoring the efficiency of the lines transporting the steam. The major concern, once a line is designed, is the integrity of the pipeline and how much steam is being lost to leakage. By placing a vortex meter at the discharge of the boiler and taking advantage of the integral temperature measurement, you can accurately measure the generated steam. If you have a flow meter on the gas feed line, you can monitor boiler efficiency by comparing gas use to pounds of steam produced. Then, by placing another vortex meter at a designated spot further downstream of the boiler, you can make the measurement again and compare the flow rate of the steam to what’s coming off the boiler. Any reduction in flow not accounted for by any usage points in between can be attributed to leakage. As you can see in the table, even a small leak can cost thousands of dollars per year, not including the additional cost it takes to manufacture more steam to compensate for the loss. Left unchecked, a 1/2” leak can cost upwards of $50,000 per year. Flow Measurement Instruments Cost of a steam leak MAGNETIC FLOWMETERS V 01.2016 Level Measurement Instruments 66 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com [email protected] Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 SITRANS FM MAGFLO Electromagnetic Flowmeters Need FM Class I, Div 1 meters? MAGFLO models are available for harsh environments. Call Lesman for help. Flow Measurement Instruments Pressure Transmitter MAGFLO flowmeters make it easier for you to manage flow. Whether it’s installation, managing operations, or verifying continuous accuracy, our customers rely on Siemens MAGFLO to improve their processes. Greater Flexibility and Expandability • One transmitter/converter electronics box fits all sensor tubes • Choice of integral mount, remote pipe or wall mount, explosion-proof, or 19” rack mount electronics styles available • Ready for your plant data network! Universal communications slot on each converter • Communication modules for HART®, Modbus RTU, Profibus PA/DP. Add-on modules allow upgrades without buying a new flowmeter Temperature Sensors and Transmitters Easier to Operate Wireless Sensing and Communications • Mag 5100W doesn’t require grounding rings • Robust construction and materials: PTFE, PFA, Ceramic, and NOVALAK liners; AISI 316 Ti stainless steel, Hastelloy C, Titanium, Tantalum, and Platinum electrodes • Only Siemens offers NOVALAK, a revolutionary liner material with a smooth, hard, non-porous finish that provides the highest level of protection against corrosion, abrasion, high pressure and temperature, and vacuum conditions. It has the chemical resistance you expect from PTFE with the mechanical strength and stability of steel. • Uniform user interface for all MAGFLO products Easier to Commission • Pushbuttons on transmitter electronics make setup easy for technicians and contractors • SensorPROM holds identity of each flowmeter: Calibration data, magnetic properties, user setup, and programming. • SensorPROM module enables instant measurement at power-up Easier to Service Analytical Instruments and Systems • Transmitter replacement requires no programming • SensorPROM automatically updates all settings after initialization Flexible Transmitter Electronics Choose between Mag 5000 (±0.5% accuracy) and Mag 6000 (±0.25% accuracy) for high performance, easy operation, and reduced maintenance. Mag 5000 is a robust solution for all-around applications. Mag 6000 is for the more demanding applications where higher accuracy and greater functionality are required. The Mag 6000i (Industry) transmitter is designed for the special demands in the process industry. The robust, full-metal housing provides superb protection, even in the harshest industrial environments. Full input and output functionality is provided, even in the ATEX EEx d version. Individual calibration and fingerprint (magnetic property) data are pre-programmed at the factory and stored in the MAGFLO’s SensorPROM module. Setup data is added during configuration. This unique combination ensures a cost-effective, easy, and errorfree installation. Plug and play communication modules make your MAGFLO compatible with your plant network protocol. Changing communications standards or moving the MAGFLO to a different network? Just swap out the communications module. No need to buy a new magmeter. Sensor Tube Designs for Every Industry Mag 5100W: A sensor for all water and wastewater applications. With its coned design, increased low-flow accuracy is achieved, making it especially useful for leak detection. It can be made suitable for direct burial and constant flooding. Mag 5100W complies with drinking water and custody transfer approvals. Mag 1100: The flangeless wafer design that meets all flange standards. The Mag 1100 is used in all industries where the corrosion-resistant stainless steel housing and highly resistant liner and electrodes fit even the most extreme process media. Mag 1100s are available with FM and ATEX approvals for installations in hazardous areas. Its obstruction-free performance minimizes the risk of deposits. And, it’s unaffected by the suspended solids, viscosity, and temperatures typically found in pharmaceutical processes. The Mag 1100 is suitable for CIP and SIP cleaning, and withstands the high pressures of hose-down. Mag 1100 Food: Specially designed for the food and beverage industry, Mag 1100F offers unique and flexible process connections. Mag 1100F was the first to pass EHEDG hygienic test and meets all sanitary standards. Its performance is unaffected by suspended solids, viscosity, and temperature changes. The Mag 1100F features an AISI 316 stainless steel enclosure with an IP67/NEMA 4X rating that is upgradable to IP68/NEMA 6P. It’s delivered with your choice of flange adapter, with metal-to-metal design, and no grounding connection required. Advanced Diagnostics of Application and Metering • Identification in clear text and error log • Error categories: Function, warning, permanent, and fatal • Transmitter self-check including outputs and accuracy • Sensor check function •Overflow • Empty pipe, partial filling, low conductivity, electrode fouling • System verification with MAGFLO Verificator Siemens has Tri‑Clover and Tri‑Clamp adapters in stock, ready for quick assembly and shipment! 2 Plug and Play communication modules and swappable SensorPROM memory module make replacing electronics quick and painless! Mag 3100: This flexible and comprehensive sensor program offers a wide range of sizes, to fit a wide variety of general industry applications. Liners and measuring electrodes capable of withstanding the most extreme processes are available. All welded construction provides a ruggedness that suits the toughest environments. Mag 3100P: Designed to meet the most common specifications in the chemical and process industries. It features fully welded construction for ruggedness, and PTFE or PFA liners and Hastelloy electrodes for flexibility. Mag 8000W: These battery-powered units give you the flexibility to install a reliable water meter almost anywhere, without sacrificing accuracy or performance. It’s optimized for leakage detection and accurate billing. The Mag 8000W features a datalogger with selectable log interval up to 26 months, an infrared (IrDA) port for on-site downloads, power management with selectable battery alarm levels, a self-check feature with automated data backup, and three totalizers, one with user reset. Transmag 2: For Heavy-Duty Applications Thanks to its pulsed AC system, the Transmag 2 is capable of measuring where conventional DC field technology fails, including applications with high concentrations of pulp stock, heavy slurries, or slurries with magnetic particles. Magnetic particles in the media boost the magnetic field in the flowmeter and cause bad readings. Transmag 2 overcomes this issue with a second compensating coil circuit. The alternating field technology generates a much stronger magnetic field within the sensor, to measure more reliability and with greater precision — even when the media has a high concentration of solids. There’s a solution to every abrasive media application, and the choice of construction material is crucial to protect the flowmeter. Besides inlet protection rings, Siemens offers a broad range of liner and electrode materials — like the soft LINATEX rubber and NOVALAK liner, which have proven themselves in these harsh environments. Need help finding the right magmeter? Download the application datasheet from www.Lesman.com/datasheets/ and send it to Lesman for engineering review. In-Situ Verification Call for Verificator Service! Using the MAGFLO Verificator, Siemens offers in-situ verification for documenting continuous accuracy for critical process applications — especially crucial when your application is required to meet ISO 9001, ISO 4001 or other quality management programs. Through in-depth analysis, Siemens has identified the parameters that influence the accuracy of a flowmeter operating in the real world. These parameters are checked using a patented verification technique for MAGFLO flowmeters. In-situ verification requires no interruption of flow, no opening of pipes, and no disconnection of cabling. The Verificator can run a full installation test of the transmitter, sensor, and cabling — all in less than 15 minutes! Transmitter Test: The transmitter test is a flow simulation test that checks the whole electronic system from signal input to output. Using the magnetic field energy, the Verificator simulates a flow signal to the transmitter input. By measuring transmitter output, the Verificator calculates its accuracy against factory-defined values. Flowmeter Insulation Test: This“cross-talk”test of the entire flowmeter ensures that the sensor flow signal is unaffected by external influences. In this test, the Verificator generates a high voltage disturbance within the coil circuit, and then looks for any cross-talk induced in the flow signal circuit. By generating dynamic disturbances close to the flow signal, the flowmeter is tested for noise immunity to a maximum level. Sensor Magnetism Test: This “boost” test of the magnetic field coil ensures that the electromagnetic signal meets the original settings. In the boost test, the Verificator changes the magnetic field pattern and uses high voltage to get quick stable magnetic conditions. Then, it compares the current sensor magnetism to the factory “fingerprint” determined during initial calibration, and stored in SensorPROM. An authorized, signed certificate documents the verification, and includes test results with pass/fail approval, installation specifications, flowmeter specification and configuration, and Verificator specification with calibration date (to ensure traceability to national and international standards.) Level Measurement Instruments Flow Measurement Instruments (2) SensorPROM Memory Module g rings. • Mag 5100W doesn’t need groundin so one universal spare covs, tube or sens all fits • One transmitter ers all applications. the keypad — contractors • Easy transmitter configuration with ! them love and technicians cation service from Siemens, • Owners can schedule on-site verifi FLO Verificator unit. a or do their own verification with MAG a quick swap-out. er serv • SensorPROM makes replacement , it’s easy to get data ules mod on • With the universal communicati ork. onto the plant netw rd of reliability, with calibration • They can produce a traceable reco data and verification test results. Pressure Transmitter 67 MAGFLO? Why Do So Many Engineers Choose (1) Universal Signal Modules for Communication 1 MAGNETIC FLOWMETERS Temperature Sensors and Transmitters Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Wireless Sensing and Communications www.lesman.com [email protected] Analytical Instruments and Systems Lesman Instrument Company V 01.2016 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 MAGNETIC FLOWMETERS V 01.2016 Level Measurement Instruments 68 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com [email protected] Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 SITRANS FM MAGFLO Electromagnetic Flowmeters Call for Verificator service Flow Measurement Instruments Integral Mount Mag 5000/Mag 6000 Rack/Panel Mount Mag 5000/Mag 6000 Remote Mount Mag 6000i (Ex d) Pressure Transmitter MAGFLO Transmitter Electronics • ULc Approved FM Class 1, Div 2 • Rated NEMA 4X and NEMA 6 • Choice of 115–230 VAC or 12–24 VAC/VDC Power • 3-Line, 20-Character Backlit Display • Can be Ordered Blind (No Local Digital Display) MAGFLO Verificator SensorPROM Memory Module MAGFLO Mag 5000 • ±0.5% Accuracy with All Sensors • 1 Current, 1 Digital, 1 Relay Output Standard • Available with HART® Communication • Only Available for Sensors 1/2” to 48” Step 1: Choose your electronics by accuracy, power, and mounting style. Add connecting cables and any accessories you need. Communication Modules Wall mount Junction Box for Mag 5000/6000 MAGFLO Mag 6000 • ±0.25% Accuracy with Selected Sensors • Advanced Batch Control Functions • Add-On Plug-In Communication Modules • Required for Use with Sensors Larger than 56” • Optional Design: Mag 6000i Industrial Enclosure Step 2:Choose your flow sensor by size and liner material. Issue your order to Siemens Industry Inc, c/o Lesman Instrument Company. Model Selection Guide Temperature Sensors and Transmitters Wireless Sensing and Communications Description Catalog Number Price Mag 5000 Transmitters; Max. Measuring Error: 0.5% of Flow Rate Integral Mount, 115-230 VAC 7ME6910-1AA10-1AA0 $1345.00 Integral Mount, 11-30 VDC 11-24 VAC 7ME6910-1AA30-1AA0 1345.00 Integral Mount, No Display, 115-230 VAC 7ME6910-1AA10-0AA0 1117.00 Integral Mount, HART®, 115-230 VAC 7ME6910-1AA10-1BA0 1555.00 Rack Mount, 115-230 VAC 7ME6910-2CA10-1AA0 1525.00 Mag 6000 Transmitters: Max. Measuring Error: 0.25% of Flow Rate Integral Mount, 115-230 VAC 7ME6920-1AA10-1AA0 1584.00 Integral Mount, 11-30 VDC 11-24 VAC 7ME6920-1AA30-1AA0 1584.00 Rack Mount, IP20/NEMA 2, 115-230 VAC 7ME6920-2CA10-1AA0 1812.00 IP66/NEMA 4 ABS Plastic Enclosure, 115-230 VAC 7ME6920-2EA10-1AA0 1834.00 Mag 6000i Transmitter: Max. Measuring Error: 0.25% of Flow Rate Remote Mount IP67/NEMA 4X Aluminum Enclosure 10-220 VDC/AC 7ME6930-2BA20-1AA2 2095.00 Mounting Kits and Hardware Wall Mount Junction Box IP67/NEMA 4X/6 FDK:085U1053 235.00 Submersible Kit for Terminal Box, for IP68, 10m w.g. Rating FDK:085U0220 144.00 21TE Panel Mount Kit for 19” Insert IP65/NEMA4 Enclosure in ABS Plastic FDK:083F5030 398.00 21TE Back Panel Mount Kit for 19” Insert IP20/NEMA 2 Enclosure in Aluminum FDK:083F5032 182.00 Polyamide Terminal Box with Lid for Field-Mount MAGFLO Sensors FDK:085U1052 222.00 Connection Plate for 19” Rack Mount FDK:083F4117 84.00 Brass Adapters, PG13.5 Male to 1/2” NPTF FDK:A6X30005543 19.00 Analytical Instruments and Systems er? the right magmet g in nd fi lp he d Nee sheet s application data back to en m ie S e th t ou it Fill d fax /datasheets/ an from Lesman.com r engineering review. Lesman fo Description Catalog Number Price Interconnect Cables (Price per foot, two lengths required per installation) Standard Interconnect Cable FDK:001STCAB ** $3.00 Special Interconnect Cable (for Empty Pipe) FDK:001SPCAB ** 4.00 ** Choose two standard or one standard and one special cables. Both are PVC jacket, three-conductor plus overall braided shield. Plug-In Communications Modules for Mag 6000 Electronics Mag6000 HART Communication Module FDK:085U0226 222.00 Mag 6000i HART Communication Module FDK:085U0321 227.00 Mag 6000 Modbus RTU/RS485 Module FDK:085U0234 222.00 Spare Parts and Accessories Mag 5000/Mag 6000 Sensorprom 2KB FDK:085U1005 69.00 Mag 5000/Mag 6000 Display Unit FDK:085U1039 170.00 Sun Shield for Remote-Mt Polyamide Covers A5E01209496 229.00 Sun Shield for Integral Polyamide Covers A5E01209550 368.00 MAGFLO Verificator MAGFLO Verificator (With Software and Adapter for IP67/Rack-Mount Models) FDK:083F5061 18560.00 Great for Drinking Water Applications Battery Powered! Flow Sensor Body Mag 8000W (Drinking Water) 0.5% Accuracy, Battery-Powered Magmeter with Standard Mag5100W Sensor, Integral Transmitter, and Integral Battery Pack (2 DCells). Qmax=Volume Unit 2” 277 GPM 7ME6810-2YJ31-2AA1 $3016.00 2.5” 440 GPM 7ME6810-3FJ31-2AA1 3027.00 3” 704 GPM 7ME6810-3MJ31-2AA1 3039.00 4” 1100 GPM 7ME6810-3TJ31-2AA1 3091.00 5” 1761 GPM 7ME6810-4BJ31-2AA1 3303.00 6” 2769 GPM 7ME6810-4HJ31-2AA1 3497.00 8” 4389 GPM 7ME6810-4PJ31-2AA1 3827.00 10” 7044 GPM 7ME6810-4VJ31-2AA1 4321.00 12” 11007 GPM 7ME6810-5DJ31-2AA1 5519.00 Now available with wireless interface. Call for details. Visit www.Lesman.com for more information on Siemens’ line of SITRANS FM MagFlo magnetic flowmeters. Get specs, manuals, and quick start guides. Sensors for General Industrial Applications Flow Sensor Body Mag3100: Neoprene Liner, 316SS Electrodes, ANSI Class 150 Carbon Steel Flanges, Carbon Steel Housing 1” 7ME6310-2DJ11-1AA2$1454.00 1.5” 7ME6310-2RJ11-1AA21473.00 2” 7ME6310-2YJ11-1AA21520.00 2.5” 7ME6310-3FJ11-1AA21544.00 3” 7ME6310-3MJ11-1AA21564.00 4” 7ME6310-3TJ11-1AA21632.00 6” 7ME6310-4HJ11-1AA22219.00 8” 7ME6310-4PJ11-1AA22769.00 10” 7ME6310-4VJ11-1AA23423.00 12” 7ME6310-5DJ11-1AA24824.00 Flow Sensor Body Mag3100P: PTFE Liner, Hastelloy C-276 Electrodes, ANSI Class 150 Carbon Steel Flanges, Carbon Steel Housing 0.5” 7ME6340-1VJ13-2AA2$1871.00 1” 7ME6340-2DJ13-2AA21702.00 1.5” 7ME6340-2RJ13-2AA21733.00 2” 7ME6340-2YJ13-2AA21757.00 2.5” 7ME6340-3FJ13-2AA21781.00 3” 7ME6340-3MJ13-2AA21809.00 4” 7ME6340-3TJ13-2AA21899.00 6” 7ME6340-4HJ13-2AA22598.00 8” 7ME6340-4PJ13-2AA23826.00 10” 7ME6340-4VJ13-2AA25209.00 12” 7ME6340-5DJ13-2AA27352.00 Sensors for Food, Beverage, and Pharmaceutical Use For Water and Wastewater Applications Flow Sensor Body Mag1100: PFA Liner, Hastelloy-C Electrodes, Includes EPDM Gaskets, SS Studs and Nuts 3/8” DN10 7ME6110-1RA10-1AA2 $1514.00 1/2” DN15 7ME6110-1VA10-1AA2 1514.00 1” DN25 7ME6110-2DA10-1AA2 1514.00 1.5” DN40 7ME6110-2RA10-1AA2 1793.00 2” DN50 7ME6110-2YA10-1AA2 2073.00 2.5” DN65 7ME6110-3FA10-1AA2 2200.00 3” DN80 7ME6110-3MA10-1AA2 2334.00 4” DN100 7ME6110-3TA10-1AA2 2868.00 Flow Sensor Body Mag1100: Ceramic Liner, Platinum Electrodes, EPDM Gaskets, SS Studs and Nuts 0.078” DN2 7ME6110-1DA20-2AA2 $1577.00 1/8” DN3 7ME6110-1HA20-2AA2 1577.00 1/4” DN6 7ME6110-1MA20-2AA2 1378.00 3/8” DN10 7ME6110-1RA20-2AA2 1378.00 1/2” DN15 7ME6110-1VA20-2AA2 1378.00 1” DN25 7ME6110-2DA20-2AA2 1378.00 1.5” DN40 7ME6110-2RA20-2AA2 1652.00 2” DN50 7ME6110-2YA20-2AA2 1928.00 2.5” DN65 7ME6110-3FA20-2AA2 2063.00 3” DN80 7ME6110-3MA20-2AA2 2202.00 4” DN100 7ME6110-3TA20-2AA2 2788.00 Flow Sensor Body Mag1100 Food: PFA Liner, Hastelloy-C Electrodes. Select Tri-Clover® or Tri-Clamp® Sanitary Adapter Below 3/8” DN10 7ME6140-1RA10-1AA2 $1514.00 1/2” DN15 7ME6140-1VA10-1AA2 1514.00 1” DN25 7ME6140-2DA10-1AA2 1514.00 1.5” DN40 7ME6140-2RA10-1AA2 1793.00 2” DN50 7ME6140-2YA10-1AA2 2073.00 2.5” DN65 7ME6140-3FA10-1AA2 2200.00 3” DN80 7ME6140-3MA10-1AA2 2329.00 4” DN100 7ME6140-3TA10-1AA2 2759.00 Tri-Clover® Sanitary Weld-In Adapter: Includes 2 Clamp Fittings, 2 Clamps, and 2 EPDM Gaskets 3/8” (1/2” Tri-Clover) FDK:083G2276 $245.00 1/2” (3/4” Tri-Clover) FDK:083G2277 245.00 1” FDK:083G2279295.00 1.5” FDK:083G2281343.00 2” FDK:083G2282369.00 2.5” FDK:083G2283412.00 3” FDK:083G2284499.00 4” FDK:083G2285583.00 Flow Sensor Body Mag 5100W: Nitrile Rubber Liner, Hastelloy C Electrodes, ANSI Class 150 Carbon Steel Flanges 1” 7ME6580-2DJ14-2AA2$1092.00 1.5” 7ME6580-2RJ14-2AA21105.00 2” 7ME6580-2YJ14-2AA21142.00 2.5” 7ME6580-3FJ14-2AA21154.00 3” 7ME6580-3MJ14-2AA21167.00 4” 7ME6580-3TJ14-2AA21217.00 5” 7ME6580-4BJ14-2AA21429.00 6” 7ME6580-4HJ14-2AA21623.00 8” 7ME6580-4PJ14-2AA21953.00 10” 7ME6580-4VJ14-2AA22447.00 12” 7ME6580-5DJ14-2AA23645.00 14” 7ME6580-5KJ14-2AA25052.00 16” 7ME6580-5RJ14-2AA25653.00 18” 7ME6580-5YJ14-2AA26283.00 20” 7ME6580-6FJ14-2AA26977.00 24” 7ME6580-6PJ14-2AA27755.00 Ideal for Applications with High Concentration of Suspended Solids (Pulp and Paper, Cement, Mining) TransMag2 Electronics: Patented Pulsed AC Magnetic Flowmeter for High Suspended Solids. IP67/ NEMA 4X Enclosure, Max. Measuring Error 0,50% Rate, 100–230 VAC Power; 1 Current, 1 Digital, 1 Relay (or 1 DI) Outputs 4-20 mA with HART Protocol 7ME5034-0AA11-2AA0 $2348.00 Profibus PA Protocol 7ME5034-1AA11-1AA0 2925.00 Mounting Bracket (Add Suffix to Model Number) -A02 99.00 Flow Sensor Body 911/E for TransMag 2: PTFE Liner, Hastelloy C4 Electrode, Remote Design, 1/2” NPT Screwed Gland, IP67/NEMA 5 Protection, ANSI Flanges 1” 7ME5610-2DJ13-2AA2$2785.00 1.5” 7ME5610-2RJ13-2AA22903.00 2” 7ME5610-2YJ13-2AA23130.00 2.5” 7ME5610-3FJ13-2AA23514.00 3” 7ME5610-3MJ13-2AA23636.00 4” 7ME5610-3TJ13-2AA23926.00 5” 7ME5610-4BJ13-2AA24100.00 6” 7ME5610-4HJ13-2AA24355.00 8” 7ME5610-4PJ13-2AA25673.00 10” 7ME5610-4VJ13-2AA26784.00 12” 7ME5610-5DJ13-2AA29108.00 14” 7ME5610-5KJ13-2AA2 9196.00 16” 7ME5610-5RJ13-2AA211011.00 Level Measurement Instruments Popular models in 1” to 12” sizes usually available to ship within two weeks! Flow Measurement Instruments 69 Pressure Transmitter MAGNETIC FLOWMETERS Temperature Sensors and Transmitters Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Wireless Sensing and Communications www.lesman.com [email protected] Analytical Instruments and Systems Lesman Instrument Company V 01.2016 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 CORIOLIS FLOWMETERS V 01.2016 Level Measurement Instruments 70 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com [email protected] Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 SITRANS FC Coriolis Mass Flowmeters Flow Measurement Instruments Mass 2100 Coriolis Mass Flow Sensor FC300 Coriolis Mass Flow Sensor • Accuracy >0.1% mass flow rate • Dynamic turndown ratio >500:1, from 65 kg/h to a few g/h • Densitometer performance available (Accuracy >0.001 g/cm3, repeatability >0.0002 g/cm3) • Single continuous tube design, with no internal welds, reductions or flow splitters offers optimal hygiene, safety • Market’s biggest wall thickness ensures optimal corrosion resistance and high-pressure durability • Intrinsically safe Ex ia standard • Accuracy >0.1% mass flow rate • Dynamic turndown ratio >500:1 • One tube with no internal welds, reductions, or flow splitters • Balanced pipe design ensures optimal stability under harsh and unstable process conditions • Four-wire Pt1000 temperature measurement for accurate mass flow, density and fractional flow • Intrinsically safe Ex ia IIC standard Pressure Transmitter MASS 2100 coriolis mass flow sensor is designed for low flow measurement in liquids and gases. One unit measurs mass flow, volume flow, density, temperature and fraction. MASS 2100 can be connected to MASS 6000 transmitters for remote installation only. Specifications Temperature Sensors and Transmitters Pipe: Inside Diameter: 1.5 mm (0.06”); Wall Thickness: 0.25 mm (0.010”) Measuring Range: Mass Flow: 0–143 lb/h; Density: 0–0.10 lb/in3; Fraction: 0–100° Brix; Temperature: -58° to 257° F (Optional 356° F); Liquid Pressure Measuring Pipe: Stainless steel: 3336 psi at 68° F; Hastelloy C22/2.4602: 5294 psi at 68° F Construction: Measuring pipe/connection: 316L stainless steel; Hastelloy C22/2.4602; Enclosure: IP65 316L stainless steel Connection: 1/4” NPTM ANSI/ASME B1.20.1 Approval: Ex ia IIC T3-T6, DEMKO 03 ATEX 135252X Mass 6000 Mass Flow Transmitter Wireless Sensing and Communications Analytical Instruments and Systems • For mass flow rate, volume flow rate, density, temperature, fraction flow (e.g., Brix) • One current output, one frequency/ pulse output, one relay output, one digital input; All outputs can be individually configured with mass, volume, or density • Adjustable flow direction, with single and bidirectional flow measurement • Limit switches with one or two limits, programmable for flow, density or temperature • Full batch controller • Two built-in totalizers count positive, negative or net • Noise filter for performance in tough environments • Auto zero adjustment with zero point evaluation feedback • Full service menu for effective use and troubleshooting • Compatible with MASS 2100, FC300 and other flow sensors SITRANS FC300 sensor offers superior performance in flow and density accuracy, and turndown ratio. The compact enclosure fits in tight installation spaces for measuring liquids and gases. It can be installed in horizontal or vertical position. FC300 can be connected to MASS 6000 transmitters for remote installation only. Specifications Sensor Size: DN 4 (1/6”) Mass Flow: Range: 0–772 lb/h; Accuracy: 0.1 % of rate; Repeatability: 0.05 of rate; Max. Zero Point Error: 0.022 lb/h Density: Range : 0–0.105 lb/in3; Density Error: 0.00025 lb/in3; Repeatability Temperature: -40° to 239° F (Optional to 356° F); Temperature Error: 0.9° F Brix: 0–100°; Error: 0.3° Brix Pipe: Inside diameter: 0.14“; Wall thickness: 0.0098“; Liquid pressure measuring pipe: 1885 psi at 68° F Construction: 316L stainless steel; Measuring pipe/connection: Hastelloy C22/2.4602; Enclosure: IP67/NEMA4 316L stainless steel Connection: 1/4” NPTM, ANSI/ASME B1.20.1 Approval: UL Class 1 Div. 1, Groups A–D, ATEX Specifications t mass Learn more abou sman.com. flowmeters at Le Current Output: 0/4–20 mA; Load: < 800 Ω; Time constant: 0–99.9s adjustable Digital Output: Frequency: 0–10 kHz, 50 % duty cycle; Time constant: 0–99.9s adjustable; Active: 24 VDC, 30 mA; Passive: 3–30 VDC, max. 110 mA Change-Over Relay: Load: 42 V/2 A peak; Functions: Error level, error number, limit, flow direction Digital Input: 11–30 VDC; Start/hold/continue batch, zero point adjust, reset totalizer 1/2, force output, freeze output Cut-Off: Low-flow 0–9.9% max flow; adjustable density or empty pipe cutoff Limit Function: Mass flow, volume flow, fraction, density, sensor temperature Totalizer: Two eight-digit counters for forward, net or reverse flow Display: Backlit alphanumerical text, 3 x 20 characters for flow rate, totalized values, settings and faults. Reverse flow indicated by negative sign Zero Point Adjustment: Via keypad or remote via digital input Communication: Add-on modules: HART®, PROFIBUS PA and DP, MODBUS RTU RS-485, DeviceNet, FOUNDATION Fieldbus H1 Enclosure: Rating IP67/NEMA 6 Fiberglass reinforced polyamide; Supply Voltage: 24 VDC/AC, 50–60 Hz NAMUR: Within the value limits according to "General requirements“ with error criteria A in accordance with NE 21 Cable Glands: Two 1/2” NPT or M20 polyamide cable glands SITRANS FC430 Coriolis Mass Flowmeter • Compact design: Install anywhere, fit multiple units into tight spaces; Sizes available from 1.2” to 3” • Flange, pipe thread, hygienic thread and hygienic clamp connections available • HemiShape flow manifold for low pressure loss; Avoids cavitation and separation of fragile fluids; Ideal for hygienic use (EHEDG/3A approved) • 4-20 mA analog output with HART® 7.2 standard. Other I/O can be configured for analog, pulse, frequency, relay, or status • FCT030 transmitter available in remote and compact versions, mountable on all FCS400 sensor sizes DN15 to DN80 • Fully rotatable (0-180°) pedestal makes access possible from all sides, includes simple one-bolt release clamp Streamlined, compact SITRANS FCS400 sensor The SITRANS FCS400 coriolis mass flow sensor was designed for superior performance and reliability: a very stable zero point, low pressure loss, and high immunity to process noise and plant vibrations. FCS400 is the most compact sensor available in today’s mass flowmeter market. The small size makes installation and replacement easy, and possible to fit multiple units into tight spaces. The Siemens CompactCurve tube shape offers a 0.1% flow rate accuracy and high sensitivity for optimal measurement, even with very low flows. The unit is self-draining and highly resistant to pressure burst. The ultrashort tube provides better than 1 kg/m3 density accuracy. HemiShape flow manifold design ensures balanced flow between tubes and makes the FC430 great for use in fragile liquids. It includes purge connectors for monitoring, safety relief valves, and rupture discs. The unique design secures low pressure loss and avoids cavitation at the separation of fragile liquids — ideal in hygienic applications. Its smooth surface allows for easy cleaning with minimal flow abstraction. Models can be ordered for standard, hygienic, or NAMUR service, and can be validated and configured for SIL2 or SIL3 operation standard. (SIL3 requires two flowmeters in series, monitored by a SIL-rated control system). SITRANS FCS400 Sensor Specifications Sizes: DN15 (1/2”) DN25 (1”) DN50 (2”) DN80 (3”) Flow Range (Lb/h):8,157 25,353 114,640 300,000 Accuracy: ±0.10%; Repeatability: ±0.05% Pressure rating: Measuring tube: 1450 PSI; Sensor enclosure: 20 bar for 1/2” and 1” models, 17 bar for 2” and 3” models Temperature: Process: -58° to 392° F; Ambient: -40° to 140° F Material: Wetted parts: 316L SS; Enclosure: IP67-rated 304 SS Process connections: Flanges: EN1092-1 B1 and D, ANSI/ASME B16.5, JIS; Pipe threads: ASME (NPT), BSPP, VCO Quick-Connect; Hygienic threads: DIN11851, DIN11864-1, ISO2853, SMS1145; Hygienic clamps: DIN11864-2, DIN32676, ISO2853, SMS1145 Approvals: Hazardous area: ATEX, IECEx, FM, NEPSI, CSA, TISS, GOST; Pressure equipment: PED, CRN; Hygienic: 3A, EHEDG; Custody transfer: SITRANS FC430 OIML R 117; Operational safety: SIL2 • Can be validated and configured for SIL2 or SIL3 operation • Meets all IEC Ex, ATEX, and FM hazardous area requirements • Standard Siemens local user interface (LUI): Reduces training needs for added cost and time-efficiency. Full graphical display, straight-forward commissioning, simple navigation, customized top-level views, standard programming wizards provide guidance for the inexperienced user • Superior isolation and resistance against external vibrations for 0.1% accuracy, 0.05% repeatability, and no twisting • MicroSD card stores user and factory settings, calibration data and certificates. For audit trails and quick transfer of information to PC or between transmitters • Remote FCS400 model’s digital sensor link guarantees high-speed data transfer, even with up to 200 meters between sensor and transmitter One SITRANS FC coriolis mass flowmeter can measure: Mass Flow Rate Total Mass Density Temperature Brix Volumetric Flow Rate Level Measurement Instruments Need help choosing a coriolis mass flowmeter? Not sure coriolis is right for your application? Fill out the application datasheet from www.Lesman.com/datasheets and fax it back to Lesman. Flow Measurement Instruments 71 Pressure Transmitter CORIOLIS FLOWMETERS Total Volume Fraction Flow % or Total Fraction Innovative and user-friendly SITRANS FCT030 transmitter Based on patented digital signal processing technology, the SITRANS FCT030 transmitter delivers true multi-parameter measurements with enhanced efficiency, security and simplicity. Fully modular for installation and replacement; can be remote or compact mounted with all SITRANS FCS400 sensor sizes. Fully graphical interface display can be customized to show you different information during measurement and diagnostics. Measurement views include multivariable numeric display, bar graphs, and trend curves. On-screen diagnostics include timestamp and NAMUR results. Four navigational buttons, help text, and wizards for processes make servicing the transmitter easy. The common Siemens menu structure, display layout, and input methods reduces the need for user training. The SensorFlash MicroSD card serves as a removable database of operational user information and provides direct access to all relevant certificates and audit trails. SITRANS FCT030 Transmitter Specifications Input/Output Channels: Up to 4 channels combining analog, relay or digital outputs and binary input Signal Processing: 100 Hz Communication: HART 7.2 Power supply: 24-90 VDC, 100-240 VAC EMC performance: EN 61326-3-2 Local User Interface (LUI): Full graphical display, 240 x 160 pixels Construction: IP67-rated aluminum with corrosion-resistant coating Mechanical load: 18 to 1000 Hz random, 3.17 G rms, in all directions Approvals: Hazardous areas: ATEX, IECEx, FM, NEPSI, CSA, TISS, GOST; Hygienic: 3A; NAMUR; Custody transfter: SITRANS FC430 OIML R 117; Operational safety: SIL3 (transmitter and redundant system) Temperature Sensors and Transmitters Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Wireless Sensing and Communications www.lesman.com [email protected] Analytical Instruments and Systems Lesman Instrument Company V 01.2016 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 ULTRASONIC FLOWMETERS V 01.2016 Level Measurement Instruments 72 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com [email protected] Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 SITRANS F US Clamp-On Ultrasonic Flowmeters Comparing SITRANS F US Clamp-On Flowmeter Configurations Model Flow Measurement Instruments Replaces... SITRANS FTS020 Basic SITRANS FUS1010 Standard SITRANS FUP1010 Portable FUE1010 Energy Industry Applications FUH1010 Hydrocarbon Industry Applications FUG1010 Gas Industry Applications Controlotron 1020 Controlotron 1010N, 1010X, 1010WX Controlotron 1010P, 1010WP Controlotron 1010EN, 1010EP Controlotron 1010DV, 1010V, 1010B Controlotron 1010GC ±40 ft/sec (±12 m/s) bidirectional Flow Range Pressure Transmitter Flow Sensitivity 0.001 ft/sec (0.0003 m/sec) flow rate independent 0.001 ft/sec (0.0003 m/sec) flow Temperature Sensors and Transmitters Optional Inputs None Outputs 4–20 mA DC 1x for single channel 1x 0–5 kHz pulse rate, digital isolated RS232 Accuracy 1–2% actual volume reading (Higher accuracy is dependent on pipe condition) Wireless Sensing and Communications ±0.15–1.0% flow 0.05–0.1% actual volume reading for 5-100 ft/sec (1.5–30 m/sec) velocities, pipe condition dependent Two 4–20 mA DC, Two 0–10 VDC, Two 4-Wire 1kΩ RTD ±0.5–1.0% flow for velocities >1 ft/sec (0.3 m/sec) ±0.005–0.01 ft/sec (±0.0015–0.003 m/sec) for velocities <1 ft/sec (0.3 m/sec) Analytical Instruments and Systems Approvals Prices Start at ±0.5–2.0% flow for velocities >1 ft/sec (0.3 m/sec) ±0.005–0.01 ft/sec (±0.0015–0.003 m/sec) for velocities <1 ft/sec (0.3 m/sec) ±0.5–1.0% flow for velocities >1 ft/sec (0.3 m/sec) ±0.005–0.01 ft/sec (±0.0015–0.003 m/sec) for velocities <1 ft/sec (0.3 m/sec) ±0.15% flow for velocities >1 ft/sec (0.3 m/sec) ±0.0015 ft/sec (0.0005 m/sec) for velocities <1 ft/sec (0.3 m/sec) 5 Hz NEMA 4/IP65 Liquid Temperatures Power Supply Two 4–20 mA DC, Two 0–10 VDC, Two 4-Wire 1000Ω RTD, Totalizer commands (clear/hold) Two 4–20 mA DC (1kΩ at 30 VDC), Two 0–10 VDC (5kΩ min.), Four SPDT relays for status alarms, Two 0–5 kHz frequency, RS232 Data Refresh Enclosure Ratings 1” to 60” (DN 25 to DN 152) 0.25” to 360” (DN 6.4 to DN 9140) Pipe Sizes Batch Repeatability 0.001 ft/sec (0.003 m/sec) flow rate independent NEMA 4X/IP65, NEMA 7/IP65, NEMA 7/IP66 Four 4–20 mA user selectable, Two 4-Wire 1000Ω RTD Two 4–20 mA, Two 4-Wire 1000Ω RTD Two 4–20 mA DC (1kΩ at 30 VDC), Two 0–10 VDC (5kΩ min.), Four 0–5 kHz pulse rate (None for NEMA 7/IP65 version), RS232 Two 4–20 mA DC programmable standard, Two 0–10 VDC, Four 0–5 kHz, RS232 0.5–1.0% flow, calibratable to 0.15–0.3% of flow, 0.05 of API number (interface detector) Out of box 1-2%, calibratable to 0.5% ±0.005–0.01 ft/sec (±0.0015–0.003 m/sec) for velocities <1 ft/sec (0.3 m/sec) 0.05% (depending on model) ±0.10–0.2% flow for velocities >1 ft/sec (0.3 m/sec) ±0.15% flow for velocities >1 ft/sec (0.3 m/ sec) ±0.0015 ft/sec (0.0005 m/sec) for velocities <1 ft/sec (0.3 m/sec) 5 Hz (80 Hz output optional) IP67 NEMA 4X/IP65, NEMA 1/IP40 NEMA 4X/IP65, NEMA 7/IP65, NEMA 7/IP66 -40° to 250° (-40° to 120° C) standard; -40° to 450° F (-40° to 230° C) optional -40° to 140° F (-40° to 60° C) Call for higher temps. 100–240 VAC, 50/60 Hz, 30 VA, 9–36 VDC, 12W 90–240 VAC, 50/60 Hz, 30 VA, 9–36 VDC, 12W 100–240 VAC, 50/60 Hz, 9–36 VDC, 10W Internal NiCad battery (4 hour) 90–240 VAC, 50/60 Hz, 30 VA, 9–36 VDC, 12W 90–240 VAC, 50/60 Hz, 15 VA or 9–36 VDC, 10W FM, CSA, ATEX, INMETRO, GoST 90–240 VAC, 50/60 Hz 30 VA or 9–36 VDC, 12W UL, ULc, CE FM, CSA, ATEX, CCOE, INMETRO, GoST UL, ULc, CE FM, CSA, CE (fixed) UL, ULc, CE (portable) $3509.00 $3857.00 $5136.00 $4697.00 $7595.00 $9141.00 Engineering specifications and more available online. Learn more about Siemens SITRANS F US Clamp-On Ultrasonic Flowmeters by visiting www.Lesman.com/get/SICF.php Don’t guess how much money’s flowing through your pipe. Clamp-on and know! • Measure practically any liquid and gas • Performance unaffected by viscosity, flow rate, pipe size, solids and aeration content • High accuracy and repeatability through automatic temperature compensation and zero drift correction • Install on pipe sizes up to DN9140 (360”) With no moving parts to wear or foul, no need to cut the pipe for installation, and high accuracy WideBeam ultrasonic flow measurement technology, you have nothing to lose. Siemens’ clamp-on ultrasonic flow technology offers several advantages over other flow measurement methods. Transducers mount quickly and easily on the outside of the pipe, so they’re ideal for retrofit applications or anywhere corrosive, toxic or high pressure liquids and gases rule out the option of cutting the pipe. The Transducer is Key Transducers for Siemens ultrasonic clamp-on flowmeters are available with Doppler and WideBeam transit time measurement technologies, so there’s a solution to work in practically any installation. Doppler operation is suggested for liquids with extensive suspended solids or aeration, and offers up to 2% flow accuracy. WideBeam transit time operation is the preferred mode for relatively homogeneous liquids. Accuracy is up to 0.5% of the flow. The patented WideBeam technology increases measurement precision by reducing the sensitivity to any change in the medium type or physical properties. The signal-to-noise ratio is optimized by using the resonant frequency of the pipe wall to transmit the sound signal into the media, with the wall acting as a waveguide. This method produces a focused, coherent signal that makes the technology particularly valuable for hydrocarbon and gas applications. For added flexibility, flowmeters are available that allow switching between Doppler and WideBeam to quickly adapt to varying conditions without changing meters. SITRANS FUS1010: Versatility and Flexibility Ultrasonic flowmeters can be used within a wide variety of applications and industries, so they’re quickly becoming the metering technology of choice. The versatile SITRANS FUS1010 illustrates this perfectly. It offers numerous advantages in application adaptability that cannot be matched by any other single flow measurement technology: zero pressure drop, insensitivity to outside noise, high turn-down ratio, interface software, and WideBeam and Doppler modes. The SITRANS FUS1010 is available in single, dual channel/beam, and four channel configurations plus your choice of three enclosures: NEMA 4X/IP65 wall mount, NEMA 7/IP65 compact, and NEMA 7/ IP66 wall mount. To accommodate more basic applications, the low cost SITRANS FTS020 comes with WideBeam and as single and dual channel versions, allowing either one or two measurement points. SITRANS FUP1010 Portable Flowmeter for Check Metering and Survey Applications For applications that don’t need constant flow monitoring or pipes where operators need to check the flow against a known or expected value, Siemens offers portable clamp-on ultrasonic flowmeters. The SITRANS FUP1010 is available with a waterproof IP67 enclosure that makes it ideal for outdoor use. The rugged, impact resistant plastic case simply enables it to withstand rough treatment that would damage most other meters. SITRANS FUP1010 operates on AC or DC power. It has an internal battery that provides 4 hours of operation and can be recharged in 1.5 hours. Temperature Sensors and Transmitters Flowmeter configuration... there’s an App for that! Since the accuracy of a clamp-on ultrasonic flowmeter depends on choosing the right transducer, this is a crucial step in the meter configuration. Siemens offers four types of transducers: universal, universal high temperature, high precision and Doppler. Before deciding on the most appropriate transducer, consider these factors: pipe thickness, diameter and material, liquid/gas type, and amount of aeration. By evaluating all of these aspects before choosing your final configuration, you are sure that your meter will work exactly the way you want it, right from day one. With flexible configuration options combined with permanent and portable versions, finding exactly what you need has become a lot easier. Customize your flowmeter by choosing necessary transducers, number of channels and enclosures, or select a complete pre-configured system available for HVAC, power, and hydrocarbon industries. As a crucial accessory, the clamp-on program also includes an easy-to-use, stand-alone digital ultrasonic pipe wall thickness gauge. Since even the smallest pipe thickness miscalculations can have an impact on accuracy, this high precision gauge is an indispensable flow measurement tool. Level Measurement Instruments 73 Flow Measurement Instruments ULTRASONIC FLOWMETERS Pressure Transmitter Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Wireless Sensing and Communications www.lesman.com [email protected] Analytical Instruments and Systems Lesman Instrument Company V 01.2016 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 ULTRASONIC FLOWMETERS V 01.2016 Level Measurement Instruments 74 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com [email protected] Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 SITRANS F US Clamp-On Ultrasonic Flowmeters Flow Measurement Instruments Pressure Transmitter With the dual channel version, switching between WideBeam and Doppler operation for quick adaptation to varying conditions can take place without changing meters. This makes is suitable for any liquid; even those with high aeration or suspended solids. Using the meter’s internal datalogger, process history can be recorded and stored or downloaded to a PC or laptop. Check Metering Kits Temperature Sensors and Transmitters If you need a portable meter that needs to be moved often as part of a flow survey or flow check measurement, pre-configured check metering kits are the ideal solution. They can be used for checking the performance and accuracy of any type and brand of flow or energy meter. Kits come in rugged, weatherproof rolling cases with telescoping handles. The case holds all the equipment — cables, multiple transducers and the ultrasonic flow computer; no need to order extra parts. Clamp-on ultrasonic check metering kits are available for water and wastewater, oil and gas, and energy industry applications. Water and Wastewater Application Solutions Wireless Sensing and Communications Ultrasonic WideBeam transit time and Doppler flowmeters are engineered to measure a wide range of flow applications found in the municipal water and wastewater industries. They can be mounted on any pipe size and material, and range from simple single meter installations to full flow metering or leak detection systems in large distribution and collections systems plants. Single, dual or four channel configurations facilitate the installation on a very wide range of applications. Dual channel meters can be set up on two separate applications and can also provide math functions between the two channels. The same applies for the four channel meter, which can monitor four lines and also has math and multipath functions. and specific gravity at base temperature and pressure at both reference and current operating conditions. The SITRANS FUH1010 for accurate standard volume/mass flow measurement is required for high end application such as varying viscosity liquids and multi-product pipelines. It’s also ideal for line balance applications that require normalized volume or mass output. Outputs are available for density and API. For even more precise density compensation, analog inputs from densitometers, temperature sensors, viscometers and pressure transmitters can be used. SITRANS FUE1010 for Energy and Power Applications The rugged, high precision SITRANS FUE1010 flowmeter is ideally suited for thermal energy and power applications, and large pipe sizes. Key applications include high precision revenue grade sub-metering of thermal energy production, chilled or hot water HVAC installations, measurement of ammonia and glycol mixtures, and energy efficiency monitoring of HVAC equipment and nuclear power plants. As a stand-alone energy meter, the FUE1010 can be used as a remote communication module. Inputs from other data sources are transferred into the built-in data logger, making it easy to time-stamp all data and download it for billing, efficiency and operation analysis. SITRANS FUH1010 for Hydrocarbon Industry Applications Analytical Instruments and Systems Siemens SITRANS FUH1010 meters are specifically designed to address the needs of the hydrocarbon industry in applications where traditional meters cannot perform. • Continuous operation with highly aerated liquids • Flow measurement under a wide range of viscosities • Easy and quick installation with zero process down time • High performance under less than ideal flow profile conditions SITRANS FUH1010 flowmeters are ideal for crude oil, refined petroleum or liquefied gas applications. They are available in single, dual, three or four beam versions and use WideBeam technology for maximum accuracy. Clamp-on flowmeters for the hydrocarbon industry are available in three different versions. The temperature- and pressure-compensated SITRANS FUH1010 interface detector offers extremely precise interface, crude oil and multiproduct identification. It is ideal for scraper “pig” and density indication. The system provides outputs for API number, density, Flowmeter Software for Diagnostics and Data Analysis Easy to use DataView software provides diagnostic capabilities, data logging and trending of meter performance. This diagnostic assures calibration and operational integrity. AGA-10 speed of sound calculation is incorporated in the software for speed of sound verification. An internal AGA-8 table for fixed gas composition is available for standard volume computation. Single, dual, or optional four beam versions are available along with rugged, stainless steel transducer enclosures permit permanent and direct burial installations. Quick Configurations for Popular Models FUS1010 standard clamp-on flowmeter, NEMA 4/IP65 enclosure. Includes two 0-10 VDC, two 4-20 mA and two 0-5 kHz pulse outputs and four Form C relay outputs, 90-240 VAC power, RS232 Modbus RTU communications. Model Selection Guide Issue all orders to: Siemens Industry Inc, c/o Lesman Instrument Company Description FUS1010 Standard Clamp-On Flowmeter Channels/ Single Channel Beams Dual Channel/Dual Beam No Sensor C3 Universal, 13” Mounting Frame Channel 1 D3 Universal, 24” Mounting Frame Transducer D1H High Precision 48” Mounting Frame D2H High Precision 48” Mounting Frame Doppler Strap Kit up to 12” Channel 2 No Transducer Transducer D1H High Precision 48” Mounting Frame Doppler Strap Kit up to 12” ID Tag Stainless Steel, Max 68 Characters 1 x PVC-Jacket, 20’ Sensor 1 x PVC-Jacket, 50’ Cable 1 x PVC-Jacket, 100’ 1 x PVC-Jacket, 150’ 1 x PVC-Jacket, 200’ Catalog NumberPrice 7ME3530- $3857.00 1AA00- 0.00 2AA00- 949.00 0A_ _ 0.00 0D_ _ 1621.00 0E_ _ 1621.00 0P_ _ 2147.00 0Q_ _ 2345.00 0S_ _ 903.00 _ _A1 0.00 _ _P1 2147.00 _ _S1 903.00 ,Z-Y19 93.00 ,Z-K01 109.00 ,Z-K02 121.00 ,Z-K03 213.00 ,Z-K04 354.00 ,Z-K05 400.00 FUP1010 portable clamp-on flowmeter, IP67 weatherproof, battery powered. Includes RTD mounting hardware and cable, pipe mounting kit and spacer bars for each transducer. Call for high temperature transducers. Model Selection Guide Issue all orders to: Siemens Industry Inc, c/o Lesman Instrument Company Description FUP1010 Portable Clamp-On Flowmeter Channels/ Single Channel Beams Dual Channel/Dual Beam No Sensor Cable Sensor 1 x PVC-Jacket, 20’ Cable 2 x PVC-Jacket, 20’ 1 x PVC-Jacket, 50’ 2 x PVC-Jacket, 50’ Battery None Charger Charger Type K for U.S. (NEMA 5-15P) No Transducer Channel 1 A2 Universal, 3” Track Mount Transducer B3 Universal, 5” Track Mount C3 Universal, 13” Mounting Frame ID Tag Stainless Steel, Max 68 Characters Catalog NumberPrice 7ME3510- $5136.00 10C _ _ _- 0.00 20C _ _ _- 1033.00 _ _ _A0 _- 0.00 _ _ _B0 _- 140.00 _ _ _C0 _- 280.00 _ _ _D0 _- 185.00 _ _ _E0 _- 370.00 _ _ _ _ 0- 0.00 _ _ _ _ 5- 171.00 0AA0 0.00 0BA0 1588.00 0CA0 1588.00 0DA0 1968.00 ,Z-Y19 93.00 Siemens portable clamp-on ultrasonic flowmeters are available for rent for survey metering applications.Call for details. FST020 basic clamp-on flowmeter, NEMA 4/ IP65. Includes one 4–20 mA output per channel and 1 pulse output (single channel model only.) Transducer includes pipe mounting kit. Unit is UL, cUL, and CE approved standard. Model Selection Guide Issue all orders to: Siemens Industry Inc, c/o Lesman Instrument Company Description FST020 Basic Clamp-On Flowmeter, NEMA 4/IP65 Channels Single Channel Meter 100–240 VAC Power 11.5–28.5 VDC No Transducer Channel 1 B3 Universal, 5” Track Mount Transducer C3 Universal, 13” Mounting Frame D3 Universal, 24” Mounting Frame B2H High Precision, 5” Track Mount Sensor No Cables Cables 1 x PVC-Jacket, 20’ 1 x PVC-Jacket, 50’ ID Tag Stainless Steel, Max 68 Characters Catalog NumberPrice 7ME3570- $3509.00 1H _ _ _- 0.00 _ _ A00- 0.00 _ _ B00- 0.00 0A _ _ 0.00 0C _ _ 1453.00 0D _ _ 1584.00 0E _ _ 1584.00 0L _ _ 1636.00 _ _ A0 0.00 _ _ B0 107.00 _ _ C0 118.00 ,Z-Y19 93.00 Program your flowmeter with an iPhone or iPad SITRANS CONNECTION App for Apple iOS devices enables direct serial communication between an iPhone, iPad, or iPod touch and any SITRANS F US clamp-on ultrasonic flow meter to enhance all meter functions, like programming, operational review, and data logging and download. SITRANS CONNECTION App makes connectivity possible without needing a laptop PC. It simplifies programming with a full alphanumeric keypad for easier navigation and parameter entry. Plus, it lets you share access to your terminal window with a qualified service technician (Wi-Fi or cellular service required). How to Order Flowmeter You can order the SITRANS CONNECTION configuration... IOS app through the Apple iTunes store or there’s an App from Siemens. When you order the software for that! from Siemens, you’ll receive an iTunes redemption code. At that point, you can download the app from the iTunes store. You will need to purchase a Siemens cable kit to connect your Apple device to the Siemens clamp-on ultrasonic flowmeter. Select the cable (or cables) you need based on your flowmeter model. Model Selection Guide Description SITRANS Connection App: iTunes Redemption Code Cable Kit–IP67 FUP Weather Proof Portable Meter Cable Kit–IP65 FUE, FUG, FUH, FUS Meter (No Ext I/O) Cable Kit–IP65 FUE, FUG, FUH, FUS Meter (with Ext I/O), IP40 FUE Portable, FUT, FST020 Catalog No. A5E32299678 A5E32299677 A5E32299675 Price $15.00 242.00 184.00 A5E32299674 140.00 Compare SITRANS F US flowmeter models on page 72. Flow Measurement Instruments Level Measurement Instruments 75 Pressure Transmitter ULTRASONIC FLOWMETERS Temperature Sensors and Transmitters Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Wireless Sensing and Communications www.lesman.com [email protected] Analytical Instruments and Systems Lesman Instrument Company V 01.2016 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 OPEN CHANNEL FLOW MONITOR V 01.2016 Level Measurement Instruments 76 Illinois, Indiana, Missouri, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com [email protected] Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 SITRANS LUT440 Open Channel Flow Monitor Flow Measurement Instruments • Industry-leading accuracy to ±0.04” (1 mm) • Next generation Sonic Intelligence — improved performance in noisy environments • Echo profile and trend view on the display for enhanced diagnostics • Energy-saving algorithms and real time clock help you reduce pump operation cost by avoiding peak energy periods • HART® communications with access via panel interface, SIMATIC PDM, Emerson handhelds, and web-browser • Graphical Quick Start Wizards guide you through setup • Front interface with four-button programming, menu-driven parameters, and Wizard support Replaces • Datalogger records performance and alarm events retired • Wall, pipe, and DIN rail mounting configurations Siemens • Removable terminal strips for hassle-free wiring Milltronics OCM-III Pressure Transmitter A complete LUT440 system includes: s See transducer 5. -3 34 on pages 1.Controller 2. Echomax transducer 3. Additional cable lengths, as necessary 4. Optional sensor mounting flanges and aiming kits, as necessary Temperature Sensors and Transmitters An ultrasonic transducer above the primary device emits a pulse that strikes the liquid target and is reflected back as an echo. The transmit and return times are converted to digital indications of head, flow rate, and totalized flow. Specifications Wireless Sensing and Communications Analytical Instruments and Systems Range: 1 to 200 ft, transducer and material dependent Accuracy: ±1 mm (0.04”) plus 0.17% distance; High accuracy: ± 0.04” (1 mm), within 10 feet (3 m) range Resolution: Greater of 0.1% measured range or 0.08” Temperature: Ambient: -4° to 122° F (-20° to 50° C); Application: -40° to 302° F (-40° to 150° C) Interface: Back-lit LCD; Removable display, operational up to 5 m (16 ft) from enclosure base Communications: HART®, USB Programming: Four local push buttons, SIMATIC PDM Emerson AMSTM, web browser (Internet Explorer), Field Device Tool (DT), Emerson FC375/FC475 Output: Three relays: One Form C (SPDT) relay, two Form A (SPST) relays; One 4–20 mA output (active or passive) Input: Two discrete inputs (0-50 VDC max switching level) with 24 VDC bias for contact level device and/or pump interlock; One temperature sensor input for optional TS-3 temperature sensor Enclosure: Wall/Pipe/DIN Rail mount; 1/2 DIN; Type 4X/ NEMA 4X/IP 65, panel mount display IP 54 (Type 3/ NEMA 3/IP 54); Polycarbonate. Use of the knock-out on the blind lid for the panel mount version reduces the electronics enclosure rating to IP 20/NEMA 1. Power: AC version: 100 to 230 VAC ±15%, 50/60 Hz, 36 VA 10 W; DC version: 10 to 32 VDC 10W Approvals: General purpose: CE.CSAUS/C, FM, UL Listed, C-TICK; Hazardous location: CSA Class I, II, III, Division 2 (Groups A–G), CE, ATEX 3D, IECEx, C-TICK Ordering Instructions Select one option from each table section below. A complete catalog number looks like this: 7ML5050-_ _ _ _ _ - _ _ _ _ -Z Model Selection Guides Please submit orders to: Siemens Industry Inc, c/o Lesman Instrument Company. Description SITRANS LUT440 Ultrasonic Open Channel Flow Monitor Enclosure With display Display With remote panel mount display Options No display (blank lid provided) Input 100 to 230 VAC ± 15% Voltage 10 to 32 VDC Cable Inlet 3 cable inlets, cable glands not supplied 3 cable inlets, 3 M20 cable glands supplied Approvals General purpose CE, FM, CSA US/C, UL, C-TICK CSA Class I, II, III, Div 2 Groups A–G Optional Manufacturer’s test certificate Adders Stainless steel tag: Max. 27 char plain text Preset Namur NE43 failsafe setting – <3.6mA Documen- Printed English User Manual tation Printed Quick-Start Guide Printed Communications Manual Accessories Tag, stainless steel, 0.47 x 1.77”, one text line Panel Mount Cable Extension 2.5 m (8.2 ft) Cable Glands and Retaining Nuts (3-Pack) HART Modem, USB LUT400 Sunshield, 304 Stainless Steel Catalog Number 7ML5050-0C_ _ _ A _ _B _ _C _ __ _ _ 1 __ _ _ 2 __ _ _ _ 1____21DA0 1DC0 -Z-C11 -Z-Y15 -Z-N07 7ML1998-5MV01 7ML1998-5XU81 7ML1998-5NE01 7ML1930-1AC 7ML1930-1GF 7ML1930-1GB 7MF4997-1DB 7ML1930-1GE Price $ 1936.00 135.00 306.00 0.00 0.00 0.00 0.00 17.00 0.00 66.00 25.00 18.00 43.00 48.00 43.00 31.00 48.00 57.00 20.00 603.00 235.00 Want to add a TS-3 temperature sensor? Call Lesman for pricing.
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement