48040H7K & 68036H5K +
Dryell
PELLERIN MILNOR CORPORATION
POST OFFICE BOX 400, KENNER, LOUISIANA 70063-0400, U.S.A.
MQCLFO01U1/16084A
1
3
1. English
Operator Guide—MilTouch-EX TM Control with Automated
Loading and Discharge
MQCLFO01EN/20160210
1
English
1
Published Manual Number: MQCLFO01
EN
• Specified Date: 20160210
• As-of Date: 20160210
• Access Date: 20160210
• Depth: Detail
• Custom: n/a
• Applicability: CLF
• Language Code: ENG01, Purpose: publication, Format: 1colA
Operator Guide—
MilTouch-EX
TM
Control with Automated
Loading and Discharge
PELLERIN MILNOR CORPORATION
POST OFFICE BOX 400, KENNER, LOUISIANA 70063 - 0400, U.S.A.
3
Applicable Milnor
®
products by model number:
48040H7K 48040H7N 68036H5K 68036H5N
4
Table of Contents
Table of Contents
Sections Figures, Tables, and Supplements
Chapter 1. How to Use the MilTouch-EX Washer-
Extractor Control
1.1.1.1. The Wash Formula Maintenance Display
1.1.1.1.1. To Change an Existing Wash Formula
Supplement 1: MilTouch Simulator for
Windows PCs
Figure 2: The Wash Formula Maintenance
Figure 3: The Steps in a Wash Formula
Figure 4: The Step Choices Display
Supplement 2: About the Steam Codes
1.1.1.1.2. To Add a New Wash Formula
1.1.1.1.3. To Erase a Wash Formula
1.1.1.2. The Data Transfer Display
Figure 5: The Data Transfer Display on the
Figure 6: The Data Transfer Display on the
1.1.1.3. Data Transfer with the MilTouch Programmer
1.1.1.3.1. How to Mount a USB Flash Drive to the Machine
1.1.1.3.2. How to Save Machine Configuration Files
1.1.1.3.3. How to Transfer Machine Configuration Files to a
1.1.1.3.4. How to Save and Transfer Wash Formulas
1.1.1.4. The Data Log Displays
1.1.1.4.1. The Date Selection Display
1.1.1.4.2. The Production Display
1.1.1.4.3. The Configuration and Programming Display
1.1.1.5. The Inputs and Outputs Displays
1.1.2.1. The Names and Timers on the Run Display
1.1.2.2. The Machine Status Data
1.1.2.3. The Machine Operations
Figure 7: Date Selection Display
Figure 9: Configuration and Programming
Figure 11: The Outputs Display
Figure 13: The Analog-Digital Values
Figure 14: The Spray Down Display
Figure 15: The Zones of the Run Display
Figure 16: The Names and the Timers
Figure 17: The Machine Status Data
Figure 18: The Machine Operations
PELLERIN MILNOR CORPORATION
5
Table of Contents
Sections Figures, Tables, and Supplements
1.1.2.4. The Standard and Pop-up Controls on the Run Display Figure 19: Standard Controls
Figure 20: Pop-up Controls for Water
Figure 21: Pop-up Controls for Steam and
Figure 22: Pop-up Controls for Drain
Chapter 2. How to Configure and Program the
Control
2.1. Configuration for the MilTouch ® EX Controller
BICLWC01)
Figure 23: Configuration Screens
Figure 24: Processor Board Revisions
PELLERIN MILNOR CORPORATION
6
Table of Contents
Figures, Tables, and Supplements Sections
2.1.36. Digital-to-Analog Offset
2.2. MilTouch-EX ™ Wash Formula Decisions
BICLUP01)
Figure 25: Nominal Weight button
Supplement 3: The RinSave ® Drain
PELLERIN MILNOR CORPORATION
7
Table of Contents
Sections
2.3. How to Calibrate the Flow Meter
2.4. Using Programmable Outputs
Figures, Tables, and Supplements
Supplement 4: Common Unit Conversions
Figure 29: Calibration by Weight
Figure 32: Flow Meter Calibration screen
Figure 33: Water Quantity screen
Figure 34: Access to the Programmable
Outputs Display
Figure 35: Programmable Outputs Display
Figure 36: Formula Number Data Entry
Figure 37: Programmable Outputs Display
Figure 38: Programming Display for
Chapter 3. Troubleshooting
3.1. MilTouch ™ and MilTouch-EX ™ Error Messages
BICLUT03)
3.1.2. Vibration Switch Tripped
3.1.5. 3-Wire Circuit Disabled
3.1.15. Bearing Pressure Fault
3.1.8. Check Temperature Probe(s)
3.1.18. Recirc Pump ol Tripped
3.1.10. Serial Communication Failure
Figure 39: Transducer Tube at Processor
Figure 40: Schematic of Typical Drain
PELLERIN MILNOR CORPORATION
8
Table of Contents
Sections
Figures, Tables, and Supplements
3.2. Outputs and Inputs for MilTouch-EX Controller
BICLWT02)
Table 1: Outputs on 8-output 16-input
Table 2: Outputs on 24-Output Board 1
Table 3: Outputs on 24-Output Board 2
Table 4: Inputs on 8-output 16-input Board
Table 5: Inputs on 8-output 16-input Board
Chapter 4. Automated Loading and Discharge
Information
4.1. Automated Loading and Discharge
4.1.2. Special Configuration Decisions
4.1.2.1. WTB (Automated Elbow) Configuration
4.1.2.2. Post-wash Data Pass Decisions
4.1.3. Manual Override Position Machine Functions
Figure 41: Automatic/Manual Selection
Figure 42: Main Configuration Menu
Figure 43: WTB Configuration Menu
Figure 44: Home Screen Display
Figure 45: Program Post-wash Data
Figure 46: Manual Override Window
Figure 47: Machine Loaded Prompt
9
PELLERIN MILNOR CORPORATION
Chapter 1. How to Use the MilTouch-EX Washer-Extractor Control
Chapter
1
How to Use the MilTouch-EX Washer-
Extractor Control
BICLWO01 (Published) Book specs- Dates: 20160210 / 20160210 / 20160210 Lang: ENG01 Applic: CLF
1.1. Using the MilTouch
The Milnor ® MilTouch
™
EX Control
™ EX washer-extractor control system uses a touch-sensitive display screen. All the functions and information you need to configure, program, and run the machine appear on this screen.
CAUTION 1 : Avoid Machine Damage—The touch screen works best if you use your finger to touch it with light or moderate pressure.
• Do not push hard on the glass.
• Use only a finger to touch the glass. Do not touch the screen with a tool.
Supplement 1
MilTouch Simulator for Windows PCs
The MilTouch Simulator software lets you prepare wash formulas and perform other MilTouch controller tasks without using the MilTouch or MilTouch-EX control system. The software uses the same interface as the one on the machine to help you program formulas and manage their deployment.
The contents of this document apply to both the MilTouch washer-extractor control and the
MilTouch Simulator software, with the following exceptions:
• In the PC software, the displays described in Section 1.1.1.5 “The Inputs and Outputs
Displays” do not reflect the state of any real hardware. The PC software does not simulate
inputs and outputs.
• The PC software will not simulate the actions of a formula.
• The PC software allows you to export formulas to any suitable storage device attached to your computer. The machine control exports to either a USB flash drive or to memory internal to the controller. See
Section 1.1.1.2 “The Data Transfer Display” for details.
1.1.1.
The Home Display
You can run any available wash formula from the display in
selected.
PELLERIN MILNOR CORPORATION
10
Chapter 1. How to Use the MilTouch-EX Washer-Extractor Control
3. Touch the blue Start button.
See
for information about the Run display.
Figure 1: The Home Display
Typical View
.
Legend
A. Wash Formula number
B. Wash Formula Name button
C. Start button
D. Version data
E. Scroll buttons
F. Wash Formula page indicator
G. Dealer Contact button
H. Data Exchange button
I. Wash Formula
Maintenance button
J. Configuration button
K. View Logs button
L. Inputs, Outputs, and
Digital-to-Analog button
M. Power OFF button
N. Version Details button
O. Search button
1.1.1.1.
The Wash Formula Maintenance Display
—Touch the Wash Formula Maintenance button. You can change, add, and delete wash formulas from this display.
1. Use the scroll buttons if necessary to bring the wash formula you want onto the display.
3. Use the instructions below.
11
PELLERIN MILNOR CORPORATION
Chapter 1. How to Use the MilTouch-EX Washer-Extractor Control
Figure 2: The Wash Formula Maintenance Display
Typical View Legend
A. Back button
B. Scroll Page buttons
C. Search button
D. Home button
E. Add button
F. Copy button
G. Rename button
H. Erase button
I. Programmable Outputs button (optional)
J. Steps button
K. Wash Formula Name buttons
.
1.1.1.1.
1.
To Change an Existing Wash Formula
display the steps.
Figure 3: The Steps in a Wash Formula
Typical View Legend
A. Back button
B. Name button
C. Step Type button
D. Add button
E. Copy button
F. Rename button
G. Erase button
H. Home button
. choices.
3. Touch the step parameter you want to change.
• For selection lists, touch the value you want to use.
• For fields that require a typed value, touch the value in the box at the top. When the box changes color to orange, delete the current value. Touch the desired numbers or letters to
PELLERIN MILNOR CORPORATION
12
Chapter 1. How to Use the MilTouch-EX Washer-Extractor Control enter the new value. Finally, touch the checkmark button to save the new value and go back one level. To abandon the most recent change, touch the Exit button.
Figure 4: The Step Choices Display
Typical View Legend
A. Step Choices buttons
B. Save Changes button
C. Abandon Changes button
. the
Figure 4 ) to save the changes. The control displays the steps
in the formula (
the
Supplement 2
About the Steam Codes
Use the No Steam option unless your machine is configured for steam and connected to a steam supply line.
No Steam—No steam is allowed in this bath step.
After, Runs—Steam starts only after the commanded bath level is achieved. If necessary, steam is allowed to maintain temperature. The timer runs when the steam valve is open.
Stops—Steam begins only after the commanded bath level is achieved. After temperature is first achieved, no more steam is allowed in the step. The timer stops running when the steam valve is open.
After, Stops—Steam begins only after the commanded bath level is achieved. If necessary, steam is allowed to maintain temperature. The timer stops running when the steam valve is open.
Early, After, Runs—Steam starts when the lowest safe bath level is achieved. If necessary, steam is allowed to maintain temperature. The timer runs when the steam valve is open.
Early, Stops—Steam starts when the lowest safe bath level is achieved. After temperature is first achieved, no more steam is allowed in the step. The timer stops running when the steam valve is open.
Early, After, Stops—Steam starts when the lowest safe bath level is achieved. If necessary, steam is allowed to maintain temperature. The timer stops running when the steam valve is open.
PELLERIN MILNOR CORPORATION
13
Chapter 1. How to Use the MilTouch-EX Washer-Extractor Control
1.1.1.1.
2.
To Add a New Wash Formula
2. The control names the new wash formula similar to
[N] Formula - xx
, where xx is a number.
a.
In Formula Name window, touch the formula name.
c.
Use the keypad to enter a formula name.
Maintenance display appears.
a.
Touch Add button. A new step appears with a step type of End Formula (00:00).
• For selection lists, touch the value you want to use.
• For fields that require a typed value, touch the value in the box at the top. When the box changes color to orange, delete the current value. Touch the desired numbers or letters to enter the new value. Finally, touch the checkmark button to save the new value and go back one level. To abandon the most recent change, touch the Exit button.
c.
Touch Type button on the Step Choices display, then select the type of step you want.
new value.
e.
Touch Confirm button to save the step time.
f.
Set the remaining choices for the step.
5. Repeat the steps above to add and modify steps.
1.1.1.1.
3.
To Erase a Wash Formula
3. Confirm that you want to erase the formula.
1.1.1.2.
The Data Transfer Display
—You can save wash formulas from a MilTouch machine to an external USB device or to the internal memory area in the controller.
PELLERIN MILNOR CORPORATION
14
Chapter 1. How to Use the MilTouch-EX Washer-Extractor Control
.
Figure 5: The Data Transfer Display on the Controller
Typical View Legend
A. Scroll buttons
B. Transfer Direction buttons
C. Data Set Name button
D. Transfer Wash Formulas button
E. Transfer Configuration button
F. Media Format Available indicator
G. External Storage button
H. Internal Storage button
I. Home button
J. Copy Data button
K. Rename Data button
L. Delete Data button
M. Update Operating
Software button
N. External Media button
The Media Format Available indicator lights green when the software recognizes a connected
USB device. location. whether to copy the wash formulas or the machine configuration.
Figure 6: The Data Transfer Display on the Programmer Software
Typical View Legend
A. Machine Memory Data
Set button
B. Storage Location button
C. Stored data area
.
15
PELLERIN MILNOR CORPORATION
Chapter 1. How to Use the MilTouch-EX Washer-Extractor Control
1.1.1.3.
Data Transfer with the MilTouch Programmer Software
—Use the procedures in this section to transfer these types of data between a MilTouch machine and a personal computer running the MilTouch Programmer software:
• machine configurations
• wash formulas.
1.1.1.3.
1.
How to Mount a USB Flash Drive to the Machine Controller
—This procedure requires a USB flash drive.
1. At the MilTouch machine, touch the Data Exchange button on the Home display (
access the Data Transfer display (
left side of the machine control box.
3. Touch the button in the Information box to clear the box.
4. If a green "+" is visible on the External Media button, then touch the button to mount the
USB flash drive. If a red "-" is visible on the button, continue with this procedure.
1.1.1.3.
2.
How to Save Machine Configuration Files
—This procedure requires a USB flash drive.
2. To change the name of the configuration file, touch the Rename Data button, replace the original name, and touch the button in the Information box to confirm the change.
3. Touch the bottom green Transfer Direction button to copy the configuration to the flash drive.
4. Touch the button to confirm the successful export.
6. Store the flash drive in a safe place.
1.1.1.3.
3.
How to Transfer Machine Configuration Files to a MilTouch Machine
—This procedure requires a USB flash drive that contains one or more MilTouch configuration files. The previous section describes how to save machine configuration files to a USB memory flash drive.
2. Mount the flash drive according to
4. Touch the desired configuration file in the stored data area (
5. Touch the top green Transfer Direction button to copy the configuration to the machine controller.
6. Confirm the successful import, unmount the flash drive, and remove the flash drive from the machine controller.
1.1.1.3.
4.
How to Save and Transfer Wash Formulas
1. This procedure requires a USB flash drive.
3. Mount the flash drive according to
PELLERIN MILNOR CORPORATION
16
Chapter 1. How to Use the MilTouch-EX Washer-Extractor Control
6. To copy the wash formulas from the machine to the USB flash drive, touch the Data Set
Name button.
7. To copy the wash formulas from the USB flash drive to the machine controller, touch the desired wash formula button in the list at the left of the Transfer Direction buttons.
8. Touch the available Transfer Direction button. Only one of these two buttons will be enabled.
9. When the transfer is complete, confirm the transfer, then store the flash drive in a safe place.
1.1.1.4.
The Data Log Displays
—To view the accumulated data, touch the View Logs button on the
Home display (see
Note 1: Data log displays are not available in version 2.0.112 of the display software. Version data is on the Home display ( Figure 1 ).
1.1.1.4.
1.
The Date Selection Display
—Touch the date for the log files you want to view.
Figure 7: Date Selection Display
1.1.1.4.
2.
The Production Display
—The Production display shows the wash formula number and name, the start time, and the end time for the formula.
17
PELLERIN MILNOR CORPORATION
Chapter 1. How to Use the MilTouch-EX Washer-Extractor Control
Figure 8: Production Display
1.1.1.4.
3.
The Configuration and Programming Display
—The Configuration and Programming log shows a brief description of each change made to the machine configuration or to any wash formula.
Figure 9: Configuration and Programming Display
1.1.1.4.
4.
The Errors Display
—The Errors log shows the error code and a brief description of each error condition the machine encountered.
PELLERIN MILNOR CORPORATION
18
Figure 10: Errors Display
Chapter 1. How to Use the MilTouch-EX Washer-Extractor Control
1.1.1.5.
The Inputs and Outputs Displays
—Touch any output button to actuate the output.
Touch the button again to turn the output OFF. All outputs turn OFF when you exit the Outputs
Display.
Figure 11: The Outputs Display
Typical View Legend
A. Output ACTUATED
B. Inputs Selector button
C. Outputs Selector button
D. Analog and Digital
Selector button
E. Exit button (return to
Home)
F. Scroll Pages buttons
G. Wet-down button
.
19
PELLERIN MILNOR CORPORATION
Chapter 1. How to Use the MilTouch-EX Washer-Extractor Control
Figure 12: The Inputs Display
Typical View Legend
A. Input in MADE state
B. Inputs Selector button
C. Outputs Selector button
D. Analog and Digital
Selector button
E. Exit button (return to
Home)
F. Scroll Pages buttons
G. Wet-down button
.
.
Figure 13: The Analog-Digital Values Display
Typical View Legend
A. Analog and Digital data area
B. Inputs Selector button
C. Outputs Selector button
D. Analog and Digital
Selector button
E. Exit button (return to
Home)
F. Scroll Pages buttons
G. Wet-down button
PELLERIN MILNOR CORPORATION
20
Figure 14: The Spray Down Display
Typical View
.
1.1.2.
The Run Display
[Document BICLJO01]
Figure 15: The Zones of the Run Display
All Zones
Chapter 1. How to Use the MilTouch-EX Washer-Extractor Control
Legend
A. Drain Position controls
B. Spray Down controls
C. Drain to Sewer
D. Drain to Reuse
E. Drain to Sewer Open
F. Drain to Sewer Closed
G. Drain to Reuse Open
H. Drain to Reuse Closed
I. Spray Down Enabled
J. Spray Down Disabled
Legend
A. Names and timers
(
B. Machine status data
(
C. Machine operations
(
D. Standard and Pop-up controls (
.
21
PELLERIN MILNOR CORPORATION
Chapter 1. How to Use the MilTouch-EX Washer-Extractor Control
1.1.2.1.
The Names and Timers on the Run Display
Figure 16: The Names and the Timers
A. Formula number
B. Formula name
C. Step number
D. Duration of step
E. Step time to go
F. Duration of formula
G. Formula time to go
.
1.1.2.2.
The Machine Status Data
Figure 17: The Machine Status Data
A. Status bar for formula
B. Water level achieved
C. Machine data area
D. Water temperature achieved
E. Operation indicators
F. Water valve indicators
G. Chemical signals and chemical flush valve
.
PELLERIN MILNOR CORPORATION
22
Chapter 1. How to Use the MilTouch-EX Washer-Extractor Control
1.1.2.3.
The Machine Operations
Figure 18: The Machine Operations
Legend
A. Step name
B. Cylinder motion
C. Desired water temperature
D. Desired water level
E. Date and time
F. Water level
G. Water temperature
.
1.1.2.4.
The Standard and Pop-up Controls on the Run Display
Figure 19: Standard Controls
Legend
A. Cancel formula
B. Manual controls activation
C. Diagnostics
.
Figure 20: Pop-up Controls for Water Valves
Legend
A. Hot and cold water valves configured
B. Hot water, cold water, and third water valves configured
C. Cold water, second water, and third water valves configured
.
Figure 21: Pop-up Controls for Steam and Cooldown Valves
Legend
A. Steam valve configured
B. Steam and cooldown valves configured
C. Cooldown valve configured
.
PELLERIN MILNOR CORPORATION
23
Chapter 1. How to Use the MilTouch-EX Washer-Extractor Control
.
Figure 22: Pop-up Controls for Drain Valves
A. One drain valve to the sewer
B. Drain valves to the sewer and to a reuse tank
— End of BICLWO01 —
PELLERIN MILNOR CORPORATION
24
Chapter 2. How to Configure and Program the Control
Chapter
2
How to Configure and Program the
Control
BICLWC01 (Published) Book specs- Dates: 20160210 / 20160210 / 20160210 Lang: ENG01 Applic: CLF
2.1. Configuration for the MilTouch
®
EX Controller
Use the fields described below to configure the machine for how you will use it, temperature and water units, etc.
Figure 23: Configuration Screens
Typical
.
2.1.1.
Temperature Unit (A)
Set the unit to program and display bath temperature.
2.1.2.
Language (B)
Set a language for the machine prompts.
25
PELLERIN MILNOR CORPORATION
Chapter 2. How to Configure and Program the Control
2.1.3.
Type (C)
Select the type of machine shown on the machine name plate. The name plate is on the back side of the machine.
2.1.4.
Speed Unit (D)
Set the unit to program and display basket speed.
2.1.5.
Staph Guard (E)
Set whether this machine is a Staph Guard pass-through model.
2.1.6.
Rev G / + (F)
Set whether the processor board in this machine is revision G or later. This affects how the processor board communicates with the peripheral boards.
Figure 24: Processor Board Revisions
Revision F Processor Board Revision G Processor Board
.
2.1.7.
Drain Code (G)
Set the time for drain speed between two bath steps and between a bath step and an extract step.
CAUTION 2 : Avoid Machine Damage—Do not select a drain code that provides less time at drain speed than stated on the machine configuration nameplate.
2.1.8.
Steam Error (H)
Set the time allowed for the machine to use steam to heat the water to the correct temperature.
2.1.9.
Fill Error (I)
Set the maximum time allowed for the machine to fill to the desired level.
2.1.10.
Cooldown Error (J)
Set the time allowed for the machine to complete a cooldown to a programmed bath temperature.
PELLERIN MILNOR CORPORATION
26
Chapter 2. How to Configure and Program the Control
2.1.11.
Extra Water (K)
Set whether this machine is attached to a third water source.
2.1.12.
Reuse Drain (L)
Set whether this machine has a reuse tank and a second drain valve.
2.1.13.
Overhead Tank (M)
Set whether this machine has an overhead tank.
2.1.14.
Flow Meters (N)
Set whether this machine is equipped with flow meters to measure incoming water.
2.1.15.
Tilt Type (O)
Set the tilt system for this machine:
2.1.16.
RPM Control (P)
Set whether this machine has speed control.
2.1.17.
Recirculation (Q)
Set whether this machine has the equipment required to recirculate bath liquor.
2.1.18.
AmpSaver (S)
Set whether this machine is part of a Milnor ® AmpSaver ® system to help reduce peak electricity consumption.
2.1.19.
Temperature Probe (T)
Set whether this machine has a temperature sensor. A temperature sensor allows programming a specific temperature for each bath step.
2.1.20.
Electronic Level (U)
Set whether this machine has electronic level sensing abilities (pressure transducer).
2.1.21.
Variable Speed (W)
Set whether this machine has variable speed abilities.
2.1.22.
Configure Decision Z
not used
2.1.23.
Water Levels
Set a value for each water level. Water Level 1 must be the lowest level. Water Level 3 must be higher than Level 1 and Level 2.
27
PELLERIN MILNOR CORPORATION
Chapter 2. How to Configure and Program the Control
2.1.24.
Wet-Down
Set the wet-down level for this machine.
2.1.25.
Bath Level Offset
Set a digital counts value here so the displayed bath level on the Run screen is the same as the actual bath level in the machine.
2.1.26.
Chemical Valves
Set the number of chemical valves controlled by this machine.
2.1.27.
Drain Washout
Set the number of seconds for the drain washout time.
2.1.28.
Name
Set a machine name to describe the machine on printed reports.
2.1.29.
Simulator
Set this value to YES if this software is running on a personal computer. Set this value to NO if this is a washer-extractor.
2.1.30.
Counts Per 100
Set the number of flowmeter counts accumulated when 100 units of water flow through the flowmeter. This value is calculated and entered by the controller when the flow meter is
calibrated according to Section 2.3. “How to Calibrate the Flow Meter” .
2.1.31.
Offset Valve Time
Set the number of tenths of a second before the desired number of counts is accumulated for the controller to command the water valves to close. This reduces overshoot.
2.1.32.
Jog Speed
Set the basket speed in RPMs when the operator is manually jogging the basket.
2.1.33.
Tank Temperature
Set the temperature for the overhead tank.
2.1.34.
Programmable Outputs
Set the number of programmable outputs available.
2.1.35.
Mildata
Set whether this machine is part of a Mildata network.
2.1.35.1.
Mildata Address
—Set the machine address on the Mildata network.
PELLERIN MILNOR CORPORATION
28
Chapter 2. How to Configure and Program the Control
2.1.35.2.
Formula
—Set whether this machine will pass formula data for each load to the Mildata computer.
2.1.35.3.
Work Order
—Set whether this machine will pass the work order for each load to the Mildata computer.
2.1.35.4.
Goods Code
—Set whether this machine will pass the goods code for each load to the Mildata computer.
2.1.35.5.
Customer
—Set whether this machine will pass the customer code for each load to the Mildata computer.
2.1.35.6.
Employee
—Set whether this machine will pass employee data for each load to the Mildata computer.
2.1.35.7.
Weight
—Set whether this machine will pass weight data for each load to the Mildata computer.
2.1.35.8.
Pieces
—Set whether this machine will pass the number of pieces for each load to the Mildata computer.
2.1.35.9.
Lot
—Set whether this machine will pass the lot number for each load to the Mildata computer.
2.1.36.
Digital-to-Analog Offset
Set this value to calibrate the digital-to-analog board to the inverter for basket speed.
2.1.37.
Staged RPM
Set the maximum allowed speed in RPMs for the first phase of a staged extract step.
2.1.38.
Staged Delay
Set the duration in seconds of the first phase of a staged extract step.
— End of BICLWC01 —
BICLUP01 (Published) Book specs- Dates: 20160210 / 20160210 / 20160210 Lang: ENG01 Applic: CLF
2.2. MilTouch-EX
™
Wash Formula Decisions
2.2.1.
Type
End Formula—The formula is completed and causes the controller to query for how to stop the formula.
1-Way Wash—a bath step in which the cylinder turns in one direction
2-Way Wash—a bath step in which the cylinder turns in the two directions
Soak Wash—a bath step in which the cylinder does not turn
Staged Extract—an extract step used for maximum removal of moisture
1. The cylinder speed increases from drain speed to the extract speed for 150 seconds.
• If the cylinder increases to the set speed in less than 150 seconds, the controller holds the speed until the 150 seconds completes.
PELLERIN MILNOR CORPORATION
29
Chapter 2. How to Configure and Program the Control
• If the cylinder does not increase to the set speed, acceleration continues until the 150 seconds completes.
2. After the 150 seconds completes, the step timer stops.
3. The cylinder speed decreases to a stop.
4. The cylinder turns clockwise for 8 seconds, coasts for 3 seconds, then turns counterclockwise for 8 seconds.
5. The cylinder accelerates to drain speed for 8 seconds.
6. The step timer runs while the basket accelerates to the programmed speed.
7. The step ends when the step timer reaches 0.
Standard Extract—an extract step which accelerates to cylinder to a programmed speed and maintains that speed for the programmed time
2.2.2.
Time
Program the hours, minutes, and seconds that the step timer will run before it declares that this step is complete.
Tip: Some types start the step timer after requirements are met, such as water level. The time required to meet these requirements will affect the total time of the step and the formula.
2.2.3.
Temperature
Set the temperature desired for a bath step. Units are Fahrenheit or Celsius degrees, as configured.
The valid range is 50 to 205 degrees Fahrenheit (10 to 96 degrees Celsius).
2.2.4.
Hot Water
OFF—Do not open the hot water inlet valve while the machine is filling.
ON—Use hot water while the machine is filling.
Raise Fill Temperature—The hot water valve opens only to increase the bath temperature to the desired temperature while the machine is filling.
2.2.5.
Cold Water
OFF—Do not open the cold water inlet valve while the machine is filling.
ON—Use cold water while the machine is filling.
Lower Fill Temperature—The cold water valve opens only to decrease the bath temperature to the desired temperature while the machine is filling.
2.2.6.
3rd Water
OFF—Do not open the 3rd water inlet valve while the machine is filling.
ON—Use 3rd water while the machine is filling.
Raise Fill Temperature—The 3rd water valve opens only to increase the bath temperature to the desired temperature while the machine is filling.
Lower Fill Temperature—The 3rd water valve opens only to decrease the bath temperature to the desired temperature while the machine is filling.
PELLERIN MILNOR CORPORATION
30
Chapter 2. How to Configure and Program the Control
2.2.7.
Level or Liquor Ratio
The amount of water in the machine for each bath step is normally controlled by a pressure transducer. Optionally, some models can be equipped with a flow meter to measure the amount of water that flows into the machine.
2.2.7.1.
Water Level
Level 1, 2, and 3—Fill to the level that was configured for Level 1, 2, or 3.
User Defined—Fill to a user-defined level for this step only. Units are inches or centimeters.
2.2.7.2.
Liquor Ratio
—Machines equipped with a flow meter can fill to a programmed ratio of water to goods. This ratio is defined as a programmed amount of water for the programmed nominal load weight for each formula. When the machine is loaded, the operator enters the actual weight of the load, then the machine calculates the desired number of flow meter counts to achieve the programmed ratio.
For each step that will use liquor ratio, touch the Level button, then the User Defined button. On the Water Level screen, enter the number of water units desired for the programmed nominal weight for the formula. This value must be more than the value configured for Water Level 3. the
Figure 25 ) to go to the Program Nominal Weight screen.
Figure 25: Nominal Weight button the
the formulas that use the flow meter.
31
PELLERIN MILNOR CORPORATION
Chapter 2. How to Configure and Program the Control
Figure 26: Add Formula button
3. For each formula on the Program Nominal Weight screen, touch to select the formula number, then touch the enabled Nominal Weight button to enter a nominal weight.
4. When all formulas have nominal weights assigned, touch the Back button (
return to the Formula screen.
Figure 27: Back button
PELLERIN MILNOR CORPORATION
32
Chapter 2. How to Configure and Program the Control
2.2.8.
Steam
Figure 28: Steam window
Display Legend
A. NO Steam
B. After, Runs
C. Stops
D. After, Stops
E. Early, After, Runs
F. Early, Stops
G. Early, After, Stops
.
A. NO Steam—Do not use steam in this step to achieve or to restore the bath temperature.
B. After, Runs—After the desired bath level is achieved, run the step timer, and use steam to achieve and to maintain the bath temperature.
C. Stops—After the desired bath level is achieved, use steam to achieve the bath temperature with the step timer stopped. Do not use steam to maintain the temperature.
D. After, Stops—After the desired bath level is achieved, use steam to achieve the bath temperature with the step timer stopped. If necessary, use steam to maintain the temperature.
E. Early, After, Runs—At the lowest safe bath level, use steam to achieve the bath temperature.
Start the step timer when the desired level is achieved. If necessary, use steam to maintain the temperature.
F. Early, Stops—At the lowest safe bath level, use steam to achieve the bath temperature. Start the step timer when the desired level and temperature are achieved. Do not use steam to maintain the temperature.
G. Early, After, Stops—At the lowest safe bath level, use steam to achieve the bath temperature.
Start the step timer when the desired level and temperature are achieved. If necessary, use steam to maintain the temperature.
2.2.9.
Chemical
Chemical Number (e.g., 001)—The fixed display of the chemical number.
ON/OFF—Is this chemical used in this step?
Chemical Name (e.g., Chemical 01)—Chemical name, as programmed elsewhere.
When to Inject—Choose the "With Fill" option to start the chemical injection when the water valves open to fill the cylinder. Choose the "Level OK" option to start the chemical injection when the water level in the cylinder is achived. Choose the "Level + Temp" option to start the chemical injection when the water level in the cylinder is achieved and the desired temperature is achieved.
PELLERIN MILNOR CORPORATION
33
Chapter 2. How to Configure and Program the Control
Injection Time—Number of seconds to inject this chemical.
Signal with Injection—Enable this decision to sound the operator signal and require the operator to press the Signal Cancel button before the injection begins.
2.2.10.
Speed
Wash Speed (RPM)—Range is 010 RPMs minimum to 038 RPMs maximum
Extract Speed (RPM)—Minimum value is 200 RPMs. Maximum value is determined by machine model.
2.2.11.
Drain Type
Standard—Basket rotates at approximately 1 G-force for the drain duration. Actual speed is determined by the configured machine type. The drain valve opens after a distribution delay.
2-Way Wash—Basket rotates both directions at wash speed while draining. The drain valve opens when the step timer expires.
Do Not Drain—The drain valve remains closed to keep the bath liquor for the next step. Basket rotation is determined by the following bath step.
Stop with Fill—The basket does not rotate while the machine is filling. The drain valve opens after a distribution delay.
Stop with Drain—The basket does not rotate while the machine is draining. The drain valve opens when the step timer expires.
Stop with Fill and Drain—The basket does not rotate during filling and draining. The drain valve opens when the step timer expires.
RinSave—The basket rotates according to a specific sequence, described below. The drain valve opens 10 to 15 seconds after the step timer expires.
Supplement 3
The RinSave ® Drain Sequence
1. When the bath ends, the cylinder turns clockwise at wash speed for 8 seconds.
2. Before the drain valve opens, the cylinder accelerates to the standard drain speed for 4 seconds.
3. The drain valve opens and the cylinder turns at standard drain speed for a time determined by the configured machine type.
4. The cylinder accelerates to RinSave speed for the remainder of the drain sequence.
5. If the next step is an extract step, the cylinder accelerates to the programmed speed. If the next step is a bath step, the cylinder decelerates to a stop.
2.2.12.
Re-Use Drain
To Sewer—Drain this extract step to the sewer.
Reuse Tank—Drain this extract step to a reuse tank through a secondary drain valve.
2.2.13.
How to End
Stop—The operator signal sounds, and the basket coasts to a stop.
Reversing—The operator signal sounds, and the basket reverses for 20 seconds in each direction with 3 seconds of dwell time between reversals.
PELLERIN MILNOR CORPORATION
34
Chapter 2. How to Configure and Program the Control
Rotating—The operator signal sounds, and the basket rotates clockwise at wash speed.
Tumble—The operator signal sounds, and the basket reverses at wash speed. You can open the door to remove part of the load, then press the Start button to resume basket rotation.
Stop + Signal—The operator signal sounds and the basket coasts to a stop. The operator signal stops sounding after 2 minutes.
Reversing + Signal—The operator signal sounds, and the basket reverses for 20 seconds in each direction with 3 seconds of dwell time between reversals. The operator signal stops sounding after 2 minutes.
Rotating + Signal—The operator signal sounds, and the basket rotates clockwise at wash speed.
The operator signal stops sounding after 2 minutes.
Tumble + Signal—The operator signal sounds, and the basket reverses at wash speed. You can open the door to remove part of the load, then press the Start button to resume basket rotation.
The operator signal stops sounding after 2 minutes.
2.2.14.
On Time
When a bath step turns in two directions, this is the number of seconds the motor is ON, turning the basket.
2.2.15.
Off Time
When a bath step turns in two directions, this is the number of seconds the motor is OFF, letting the basket coast.
2.2.16.
Fill from Tank
If the machine is equiped with an overhead tank, fill from the tank for this step.
2.2.17.
Recirculate Water
If the machine is equiped with recircluation piping, circulate the bath liquor out of the machine, through other devices, and back into the machine.
— End of BICLUP01 —
BICLWC02 (Published) Book specs- Dates: 20160210 / 20160210 / 20160210 Lang: ENG01 Applic: CLF
2.3. How to Calibrate the Flow Meter
The flow meter measures the quantity of water as it flows into the machine cylinder for a bath step. The MilTouch controller uses the value reported by the flow meter to close the water valves when the desired amount of water per weight unit of goods is achieved. Any unit can be used for the water unit, but the controller prompts for the actual weight of goods in each load.
Supplement 4
Common Unit Conversions
Gallons (US) = 0.12 x Pounds (US)
Gallons (US) = 0.264 x Liters or Kilograms
Kilograms = 1.0 x Liters
Kilograms = 0.454 x Pounds (US)
PELLERIN MILNOR CORPORATION
35
Chapter 2. How to Configure and Program the Control
Liters = 1.0 x Kilograms
Liters or Kilograms = 3.785 x Gallons (US)
Pounds (US) = 8.3 x Gallons (US)
Pounds (US) = 2.2 x Kilograms
A paddlewheel, a part of the flow meter located in the path of fresh water flowing into the machine, spins as water flows past it. Each revolution of the paddlewheel sends a pulse to the machine controller. The controller uses the count of the pulses to determine how much water has flowed into the machine.
2.3.1.
Application
If the programmed water level is less than or equal to the configured high water level, the programmed water level (inches or centimeters; not liters, gallons, kilograms, or pounds) is used.
If the machine is configured for a flow meter and programmed for a water level value greater than the configured high water level, the controller uses the flow meter to determine when the desired amount of water is in the cylinder.
When the operator selects a wash formula with a water level value greater than the configured high water level, the controller uses the flow meter and the actual weight of the load to calculate the actual number of units of water required. To determine how many units of water to allow into the machine, the controller prompts for the weight of each load.
For example, assume that a bath step is programmed to use 800 kilograms of water for 400 kg of goods.When the formula containing this step is selected to run, the controller will prompt the operator for a customer number and the actual weight of the load. If the load weight is 375 kilograms, the controller will proportionally reduce the amount of water admitted into the cylinder according to this equation:
(375 / 400) * 800 = 750 kilograms of water
2.3.2.
Preparation
The flow meter calibration procedure requires you to temporarily redirect water from the washerextractor to a container. Depending on the units you choose for metering the water when the machine is operating, you must be able to accurately weigh the container and its contents or accurately determine the volume of water in the container.
PELLERIN MILNOR CORPORATION
36
Figure 29: Calibration by Weight
Suggested Setup
Chapter 2. How to Configure and Program the Control
Legend
A. Weighing scale
B. Clean, empty drum
C. Hose from flow meter output
.
2.3.3.
Procedure
1. Place a large calibration container on an accurate weighing scale. Larger containers provide more accurate calibration.
Tip:
You can choose any convenient unit for calibration. Liters, kilograms, pounds, and gallons are example units.
2. Disconnect the water inlet hose between the flow meter and the machine cylinder.
3. Secure the water inlet hose so that when the water valves open, the water that would normally flow through the flow meter and into the machine cylinder instead flows into the calibration container.
Allow unimpeded flow from the machine water valves to the calibration container.
Restrictions, such as a smaller hose diameter, can make the calibration less accurate.
4. Tare the scale so that it reads zero (0) with the empty container and hose in place.
5. From the main screen, touch the Configure button (
Figure 30: Configure button
6. On the first Configure screen, be sure that the controller is configured for a flow meter
(Decision N = YES).
7. At the bottom of any Configure screen, touch the Flow meter button (
PELLERIN MILNOR CORPORATION
37
Chapter 2. How to Configure and Program the Control
Figure 31: Flow meter button the
Figure 32 ) appears, wait for the flow meter count
field to reset to 0.
Figure 32: Flow Meter Calibration screen the
Figure 32 ) to open the water valves. Water flows into
the calibration container. The flow meter count value increases as water flows past the flow meter.
10. When the desired weight or volume of water is in the container, touch the Water Valve Stop button. Do not overfill the container!
11. Touch the Water Quantity button to open the Water Quantity screen (
PELLERIN MILNOR CORPORATION
38
Figure 33: Water Quantity screen
Chapter 2. How to Configure and Program the Control
12. Enter the quantity of water that is in the calibration container, then touch the checkmark to confirm the value and return to the calibration screen.
13. Touch the Save Data button on the Flow Meter Calibration screen (
14. Connect the water inlet hose to the water inlet on the machine cylinder.
— End of BICLWC02 —
BICLWP02 (Published) Book specs- Dates: 20160210 / 20160210 / 20160210 Lang: ENG01 Applic: CLF
2.4. Using Programmable Outputs
The Milnor ® MilTouch-EX ™ controller can operate up to 20 optional output relays. You assign these relays to operate in specific formulas and steps. You also assign the event that will trigger the output, the delay before the output operates, and the length of time that the output will operate.
Figure 34 shows the button on the Formula Modification display that opens the
Programmable Outputs display.
Figure 34: Access to the Programmable Outputs Display the
Figure 35 ), touch the Add Output button to begin.
PELLERIN MILNOR CORPORATION
39
Chapter 2. How to Configure and Program the Control
Figure 35: Programmable Outputs Display
Display Legend
A. Back button
B. Scroll buttons
C. Search button
D. Data display area
E. Add Output button
F. Erase Output button
. the
Figure 36 ) appears, enter the formula for which this
output will be active.
Figure 36: Formula Number Data Entry Display
Tip:
3. Confirm the formula number to return to the Programmable Outputs display (
data display area shows that the output is available for programming.
Each programmable output usually controls exactly one function, but this function can be used in multiple formulas and steps.
PELLERIN MILNOR CORPORATION
40
Chapter 2. How to Configure and Program the Control
Figure 37: Programmable Outputs Display
Display Legend
A. Formula button
B. Step button
C. Output button
D. Event button
E. Delay button
F. Duration button
.
5. Confirm the step number to return to the Programmable Outputs display.
There are four events that can actuate a programmable output:
0 = Disabled. Use this selection to disable an existing programmable output entry. This setting prevents the output from actuating.
1 = Bath Step. Use this selection to actuate the output at the start of a bath step. The first step of a formula begins immediately after the operator presses the Start button. A bath step begins when the previous step ends. A bath step may begin before the step timer
starts running, as when a bath step requires a specified temperature.
2 = Drain.Use this selection to actuate the output at the start of a drain sequence. A drain sequence begins immediately when the step timer expires for the preceding bath step, before the basket accelerates beyond wash speed.
3 = Extract. Use this selection to actuate the output at the start of an extract step. An extract step always begins a fixed time after the drain opens in the preceding drain sequence, while the basket is accelerating from drain speed to extract speed. output.
The valid range for the delay is from 0 seconds to 9999 seconds (about 2 hours and 47 minutes). The output will not actuate if the delay is longer than the step time.
41
PELLERIN MILNOR CORPORATION
Chapter 2. How to Configure and Program the Control
Figure 38: Programming Display for Programmable Outputs
Tip: actuated.
The output will always turn off at the end of the event which controls it, even if the Duration value has not expired.
— End of BICLWP02 —
PELLERIN MILNOR CORPORATION
42
Chapter
3
Troubleshooting
Chapter 3. Troubleshooting
BICLUT03 (Published) Book specs- Dates: 20160210 / 20160210 / 20160210 Lang: ENG01 Applic: CLF
3.1. MilTouch
™
and MilTouch-EX
™
Error Messages
3.1.1.
Door Opened
The Door Opened: Close the door. Press the Start button to resume operation at the current step.
Electrical Failure: If the door is not open, turn the machine Off. Do a check with the schematic to find the cause of the error.
The controller stops the wash program and turns off all outputs. Correct the error condition, touch the Signal Cancel button, then press the Start button to resume the wash program.
3.1.2.
Vibration Switch Tripped
The Machine is not Anchored: Check the bolts that hold the machine to the floor. Tighten or replace bolts that are loose or broken. Press the Start button to resume operation at the current step.
The Load is Distributed Poorly: Do a check that there is enough water in the bath before the extract step to allow the goods to spread around the basket. Press the Start button to resume operation at the current step.
The Load is too Small: This machine works best when you fill it to the rated capacity of the machine. Wash goods in full loads. Press the Start button to resume operation at the current step.
3.1.3.
Too Long to Fill
Fill Time Configured too Short: Do a check of the configured fill time. Increase the fill time if necessary.
Low Water Pressure: Do a check of the water pressure and volume to the machine.
Water Valve Malfunctioned: Use the schematic to do a check of the water valves and the circuits that control the valves.
The controller closes all water valves and turns off all chemical injections. When you touch the
Signal Cancel button, the controller resets the Fill Error timer and resumes the wash program.
43
PELLERIN MILNOR CORPORATION
Chapter 3. Troubleshooting
3.1.4.
Too Long to Drain
Drain Blocked: The drain pipe from the machine to the sewer may be blocked. Check the drain pipe and remove obstruction.
Transducer Tube Blocked: The tube from the shell to the pressure transducer may be blocked.
Check the tube and remove lint or other obstructions.
Figure 39: Transducer Tube at Processor Board
Drain Valve Malfunctioned: The drain valve or drain valve solenoid may have malfunctioned.
Use the schematic diagram to find the problem.
Figure 40: Schematic of Typical Drain Circuit
The wash program continues, and the display continues to show the error until the operator touches the Signal Cancel button.
3.1.5.
3-Wire Circuit Disabled
This error occurs on MilTouch-EX models. Correct the error. Touch the Start button to enable the circuit.
The controller stops the wash program and turns off all outputs. Correct the error condition, touch the Signal Cancel button, then press the Start button to resume the wash program.
3.1.6.
Too Long to Steam
Low Steam Pressure: Do a check of the steam pressure from the boiler to the machine.
Steam Time Configured too Short: Do a check of the configured steam time. Set this time to the the time required to steam cold water at high level to the hottest temperature used.
Steam Valve Malfunctioned: Use manual operation to turn the steam valve On to confirm proper operation.
PELLERIN MILNOR CORPORATION
44
Chapter 3. Troubleshooting
The wash program continues, and the display continues to show the error until the operator touches the Signal Cancel button.
3.1.7.
Too Long to Cool
Cooldown Time Configured too Short: Do a check of the configured cooldown time. Increase this time if necessary.
Low Water Pressure: Do a check of the cold water pressure and volume to the machine.
Cooldown Valve Malfunctioned: Do a check of the cooldown valve for proper operation.
Temperature Circuit Malfunctioned: Do a check of the temperature probe and the analog-todigital board for proper operation.
The wash program continues, and the display continues to show the error until the operator touches the Signal Cancel button.
3.1.8.
Check Temperature Probe(s)
The Probe is Disconnected: Check the position of the probe and the connections.
The Probe Malfunctioned: Disconnect the probe and measure the resistance between the leads.
The resistance between the leads should be between 2K and 35K Ohms. The resistance between either lead and the ground should be infinite.
The temperature probe detected a temperature below 32° F (0°C) or above 230°F (110°C). If the probe connections are found good, disconnect the probe and do a check that the resistance between the leads is from 2K to 35K Ohms. Also, do a check that the resistance between each lead and ground is infinite. The wash program continues, and the display continues to show the error until the operator touches the Signal Cancel button.
3.1.9.
Level Made After Drain
Drain Blocked: Do a check that the drain valve and drain outlet are clear of debris.
Transducer Tube Blocked:The tube from the shell to the pressure transducer may be blocked.
Check the tube and remove lint or other obstructions.
Drain Valve Malfunctioned:The drain valve or drain valve solenoid may have malfunctioned.
Use the schematic diagram to find the problem.
If a slow drain caused the error, the error clears when the transducer senses that the water level in the cylinder is less than the configured low water level.
3.1.10.
Serial Communication Failure
Board Failure: A peripheral board in the control box cannot communicate with the processor board.
The controller stops basket rotation and waits for the serial communications to resume. Touch the
Signal Cancel button to end the wash program.
3.1.11.
Failed Speed Sensor
Speed Sensor Failure: The sensor that verifies that the device used to determine if the basket has stopped is not working. The processor board must receive a signal from the speed sensor at least
45
PELLERIN MILNOR CORPORATION
Chapter 3. Troubleshooting every 10 seconds to keep the door closed while the basket turns. If this device fails at extract speed, the default coast time must expire before the door will unlock.
The wash program continues. The display shows the error until the operator touches the Signal
Cancel button.
3.1.12.
Inverter Tripped
Inverter error: The inverter that controls the motor had an error. The machine controller cannot tell about the specific error. See the inverter documentation for details.
The controller stops the wash program and turns off all outputs. Correct the error condition, touch the Signal Cancel button, then press the Start button to resume the wash program.
3.1.13.
External Fault Error
This message is triggered by a device external to the Milnor machine.
This error usually originates from the chemical supply system. The wash program continues. The display shows the error until the operator touches the Signal Cancel button.
3.1.14.
Brake Pressure Fault
Brake Pressure: Low air pressure in the brake release air cylinder caused by low air pressure, a leaking air cylinder piston cup, leaking/pinched air lines, leaking quick-release air valves, or a faulty pressure switch or pilot air valve.
If the air pressure in the brake system is less than the required pressure 8 seconds after the beginning of the step, the controller stops the wash program and turns off all the outputs. Correct the error condition, touch the Signal Cancel button to reset the 8-second timer, then press the
Start button to resume the wash program.
3.1.15.
Bearing Pressure Fault
Injecting less than 5 PSI (34.5 kPa): The machine is injecting less than 5 PSI (34.5 kPa) behind the excluder seal to protect the bearings. Do a check of the air supply and the sensor circuit.
If the main bearing pressure is less than the required pressure 8 seconds after the beginning of the step, the controller stops the wash program and turns off all the outputs. Correct the error condition, touch the Signal Cancel button to reset the 8-second timer, then press the Start button to resume the wash program.
3.1.16.
Check Flow Meter
Flow Meter Malfunctioned: The level transducer detected water at the configured high level before the flow meter detected the correct number of units of water. Use the flow meter counts to determine if the flow meter is operational.
3.1.17.
Tank Pump ol Tripped
This error appears only on machines equipped with an external tank. The motor overload device for the tank pump opened to protect the pump motor.
3.1.18.
Recirc Pump ol Tripped
This error appears only on machines equipped with recirculation. The motor overload device for the recirculation pump opened to protect the pump motor.
PELLERIN MILNOR CORPORATION
46
Chapter 3. Troubleshooting
3.1.19.
Loading Aborted
This error appears only on machines equipped with an automatic loading elbow. An error occurred that caused the loading system to stop.
3.1.20.
Discharge Aborted
This error appears only on machines equipped with an automatic loading elbow. An error occurred that caused the discharge system to stop.
3.1.21.
Invalid Formula
The user entered a value for this field that does not exist in the Mildata computer.
3.1.22.
Load Eye Blocked
This error appears only on machines equipped with an automatic loading elbow.
3.1.23.
Up Lock Not Made
This error appears only on machines equipped with an automatic loading elbow. The controller can not be sure that the elbow is up and locked in a safe position.
3.1.24.
Invalid Work Order
The user entered a value for this field that does not exist in the Mildata computer.
3.1.25.
Invalid Goods Code
The user entered a value for this field that does not exist in the Mildata computer.
3.1.26.
Invalid Customer Code
The user entered a value for this field that does not exist in the Mildata computer.
3.1.27.
Invalid Employee Code
The user entered a value for this field that does not exist in the Mildata computer.
3.1.28.
Can't Find Data
Mildata machines only. The formula requested by the machine was not found on the Mildata computer.
3.1.29.
Accumulator was Reset
This error does not occur on MilTouch-EX models. The microprocessor detected that the completed-formula accumulator data was corrupt. All accumulators must be reset to zero.
— End of BICLUT03 —
47
PELLERIN MILNOR CORPORATION
Chapter 3. Troubleshooting
BICLWT02 (Published) Book specs- Dates: 20160210 / 20160210 / 20160210 Lang: ENG01 Applic: CLF
3.2. Outputs and Inputs for MilTouch-EX Controller
3.2.1.
Outputs
Tip: Some outputs can only be enabled when the 3-wire circuit is engaged. To test all outputs, enable the 3 Wire Relay, then enable the 3 Wire Plse output for 2 seconds. Turn off the 3 Wire Plse output, then proceed with testing.
Table 1: Outputs on 8-output 16-input Boards
Output
Number
0
1
2
3
0
1
2
3
Connections on
Board Function
Output
Number
8/16 Board 1
1MTA5-10 & 5-19
1MTA5-9 & 5-18
1MTA5-8 & 5-17
1MTA5-7 & 5-16
Recirculation Pump
Cooldown
Flush
Chemical 4
4
5
6
7
8/16 Board 2
2MTA5-10 & 5-19
2MTA5-9 & 5-18
2MTA5-8 & 5-17
2MTA5-7 & 5-16
Fresh to Machine
Tank to Sewer
Fresh to Tank
Flow Stop
4
5
6
7
Connections on
Board
1MTA5-4 & 5-14
1MTA5-3 & 5-13
1MTA5-2 & 5-12
1MTA5-1 & 5-11
2MTA5-4 & 5-14
2MTA5-3 & 5-13
2MTA5-2 & 5-12
2MTA5-1 & 5-11
Function
Chemical 1
Chemical 3
Chemical 2
Chemical 5
Door Lock
Steam in Tank not used
3-wire Pulse
Table 2: Outputs on 24-Output Board 1
Output
Number
Connections on
Board
0
1
2
3
4
5
6
1MTA13-1 & 13-11
1MTA13-2 & 13-12
1MTA13-3 & 13-13
1MTA13-4 & 13-14
1MTA13-5 & 13-15
1MTA13-6 & 13-16
1MTA13-7 & 13-17
7
8
1MTA13-8 & 13-18
1MTA13-9 & 13-19
9 1MTA13-10 & 14-1
10 1MTA14-11 & 14-2
11 1MTA14-12 & 14-3
Function
Tank to Machine
Alt. Accel/Decel
Door Unlock
Clockwise Wash
C-clockwise Wash
Steam Valve
Operator Signal
3-wire Relay
Brake Release
Hot Water
Cold Water
Third Water
Output
Number
12
13
14
15
16
17
18
19
20
21
22
23
Connections on
Board Function
1MTA14-4 & 14-13
1MTA14-4 & 14-14
1MTA14-10 & 14-5
1MTA14-10 & 14-15
Drain Solenoid
Reuse Drain
Machine to Machine
Machine to Tank
1MTA14-10 & 14-6
1MTA14-10 & 14-16
1MTA14-10 & 14-7
Push-down
T'fer Control #1
T'fer Control Not #1
1MTA14-10 & 14-17 T'fer Control #2
1MTA14-10 & 14-8
1MTA14-10 & 14-18
T'fer Control Not #2
Clean Signal
1MTA14-10 & 14-9
1MTA14-10 & 14-19
Wash Clutch
Spraydown
PELLERIN MILNOR CORPORATION
48
Chapter 3. Troubleshooting
Table 3: Outputs on 24-Output Board 2
Output
Number
0
1
2
3
4
5
6
7
8
9
10
11
Connections on
Board
2MTA13-1 & 13-11
2MTA13-2 & 13-12
2MTA13-3 & 13-13
2MTA13-4 & 13-14
2MTA13-5 & 13-15
2MTA13-6 & 13-16
2MTA13-7 & 13-17
2MTA13-8 & 13-18
2MTA13-9 & 13-19
2MTA13-10 & 14-1
2MTA14-11 & 14-2
2MTA14-12 & 14-3
Function
Chemical 14
Chemical 9
Chemical 13
Chemical Flush
Chemical 15
Chemical 11
ChemSave
Door Unlock Pulse
Chemical 10
Door Lock Pulse
Chemical 6
Chemical 7
Output
Number
12
13
14
15
16
17
18
19
20
21
22
23
Connections on
Board Function
2MTA14-4 & 14-13
2MTA14-4 & 14-14
2MTA14-10 & 14-5
Chemical 8
Chemical 12
Auto Recirculation
2MTA14-10 & 14-15 Drain Motor
2MTA14-10 & 14-6 Low Extract Speed
2MTA14-10 & 14-16 High Extract Speed
2MTA14-10 & 14-7 DrainSaver
2MTA14-10 & 14-17 Move to Load Posi.
2MTA14-10 & 14-8 AmpSaver
2MTA14-10 & 14-18 Move to Wash or Load
2MTA14-10 & 14-9 not used
2MTA14-10 & 14-19 Move to Wash Posi.
3.2.2.
Inputs
Table 4: Inputs on 8-output 16-input Board 1
Input Connection
Number
0
1
2
3
4
5 on Board
1MTA4-1
1MTA4-2
1MTA4-3
1MTA4-4
1MTA4-5
1MTA4-6
6
7
1MTA4-7
1MTA4-8
Function
Tank is Full
Door Closed
Inverter Input
AutoSpot Desired
Wash Position
Load Position
Do Not Allow Chemicals; Timer Stop
Basket Rotating
Input
Number
8
9
10
11
12
13
14
15
Connection on Board
1MTA4-11
1MTA4-12
1MTA4-13
1MTA4-14
1MTA4-15
1MTA4-16
1MTA4-17
1MTA4-18
Function
Excursion
Front Not Down
Brake Pads Worn
Brake is Off
Door Open Desired
Speed Limit Desired
Coarse Balance
Three Wire
Table 5: Inputs on 8-output 16-input Board 2
Input
Number
0
1
2
3
4
5
6
7
Connection on
Board
2MTA4-1
2MTA4-2
2MTA4-3
2MTA4-4
2MTA4-5
2MTA4-6
2MTA4-7
2MTA4-8
Function not used not used not used not used
I Want Clean Control
Bearing Seal Deflated not used
External Fault
Input
Number
8
9
10
11
12
13
14
15
Connection on
Board
2MTA4-11
2MTA4-12
2MTA4-13
2MTA4-14
2MTA4-15
2MTA4-16
2MTA4-17
2MTA4-18
Function not used
OK to Steam Tank
Recirc Pump Overload
Tank Pump Overload
Signal Cancel
Fresh Meter
Sewer Meter
Tank Meter
— End of BICLWT02 —
49
PELLERIN MILNOR CORPORATION
Chapter 4. Automated Loading and Discharge Information
Chapter
4
Automated Loading and Discharge
Information
BICLDO01 (Published) Book specs- Dates: 20160210 / 20160210 / 20160210 Lang: ENG01 Applic: CLF
4.1. Automated Loading and Discharge
4.1.1.
Start-up Procedure
At power-up the display prompts the user to choose either automatic mode or manual mode. See
Automatic Mode—The machine waits for input from the Miltrac control system. The Load Allowed input (2MTA4-6) and Discharge Allowed input (2MTA4-5) must be grounded.
Manual Mode—The operator controls all operations through the touchscreen and the Hydraulic Pump
Enabled button. See Figure 46 .
Figure 41: Automatic/Manual Selection
PELLERIN MILNOR CORPORATION
50
4.1.2.
Special Configuration Decisions
Figure 42: Main Configuration Menu
Menu Window
Chapter 4. Automated Loading and Discharge Information
Legend
A. Standard configuration
B. WTB (automated elbow) configuration
C. Post-wash configuration
.
®
4.1.2.1.
WTB (Automated Elbow) Configuration
Figure 43: WTB Configuration Menu
Menu Window Legend
A. Miltrac Address
B. Bytes in Network
C. Dryell
D. Clockwise Discharge
E. Counter-clockwise
Discharge
F. Dwell Discharge
G. Number of Sequences
H. End Time
I. Post-wash
J. Dryell Delay
K. Dryell Flush
L. Scroll buttons
M. Save button
N. Cancel button
.
A. Miltrac Address—the address this machine occupies on the Miltrac controller system. The valid range is 000 to 255.
B. Bytes in Network—the string length used to communicate with the Miltrac controller system
C. Dryell—set to Yes if the machine is equipped with a Milnor loading elbow. Set to No otherwise.
PELLERIN MILNOR CORPORATION
51
Chapter 4. Automated Loading and Discharge Information
D. Clockwise Discharge—the duration of clockwise rotation while discharging. Units are 1/10 second; valid range is 01 to 99.
E. Counter-clockwise Discharge—the duration of counter-clockwise rotation while discharging.
Units are 1/10 second; valid range is 01 to 99.
F. Dwell Discharge—the duration of dwell between clockwise and counter-clockwise rotation while discharging. Units are 1/10 second; valid range is 00 to 50.
G. Number of Sequences—the number of times to repeat the discharge sequence of clockwise rotation, dwell, then counter-clockwise rotation. The valid range is 02 to 20.
H. End Time—the duration that the machine will run in End mode before it desires to discharge.
Units are minutes; valid range is 0 to 850.
I. Post-wash—set to Yes if the controller should prompt for drycode and destination code information while a formula is being programmed. Set to No otherwise.
J. Dryell Delay—the desired time between when the loading process ends and the controller commands the elbow to tilt up. Units are seconds; valid range is 000 to 255.
K. Dryell Flush—the desired time for the controller to flush the elbow during the loading process. Units are seconds; valid range is 000 to 255.
L. Scroll buttons—not used
M. Save button—saves the current configuration and returns to the home screen display, shown
Figure 44: Home Screen Display
N. Cancel button—abandons the current configuration changes and returns to the home screen
4.1.2.2.
Post-wash Data Pass Decisions
—For each wash formula using post-wash codes, enter the wash formula number, the desired dryer program number, and the desired destination code.
The machine will pass the associated data to the Miltrac network or the non-Milnor allied network when each wash formula runs.
PELLERIN MILNOR CORPORATION
52
Chapter 4. Automated Loading and Discharge Information
Figure 45: Program Post-wash Data Window
Window Legend
A. Formula button
B. Drycode button
C. Destination button
D. Add New Formula button
E. Remove Formula button
. row in the table.
4.1.3.
Manual Override Position Machine Functions
These functions allow you to control certain machine functions that are usually controlled automatically. Manual control is allowed only when the machine controller determines that all requirements are met.
To use a function, first touch the function button and a direction button on the display, then hold the mechanical Hydraulic Pump Enabled button on the control panel until the operation is completed.
53
PELLERIN MILNOR CORPORATION
Chapter 4. Automated Loading and Discharge Information
Figure 46: Manual Override Window
Window Hydraulic Pump Enabled button
Legend
A. Door button
B. Tilt button
C. Elbow button
D. Load button
E. Discharge button
F. Formula button
G. Automatic Mode button
H. Up button
.
I. Down button
A. Door—Touch the Door button on the display, then touch the Up or Down button to select whether to open or close the door. Hold the Hydraulic Pump Enabled button to operate the door.
B. Tilt Rear—Touch the Tilt Rear button on the display, then touch the Up or Down button to select the tilt direction. Hold the Hydraulic Pump Enabled button to tilt the machine.
C. Elbow—Touch the Elbow button on the display, then touch the Up or Down button to select whether to move the loading elbow up or down. Hold the Hydraulic Pump Enabled button to move the elbow.
D. Load—The machine must be in the load position: rear down, door open, elbow down. Begin the load sequence to open the cold water valve and turn the basket at drain speed. The water valve closes when the water level reaches the configured tilt level. After the goods are
completely inside the machine, you must end the load sequence to stop basket rotation and close any open water valve. The sewer remains closed. Basket rotation continues until you press the Done button. Use manual controls to raise the elbow, close the door, and select a formula.
E. Discharge—The machine must be in the discharge position: rear up, door open, elbow up and locked. Begin the discharge sequence to turn the basket in each direction for the configured discharge time. After the goods are completely out of the machine, you must end the
discharge sequence. Basket rotation continues until you press the Done button. Return the machine to automatic mode or use the manual controls to operate the elbow, door, and tiltting functions.
PELLERIN MILNOR CORPORATION
54
Chapter 4. Automated Loading and Discharge Information
F. Formula—Touch the Formula button to exit the Manual Override window and return to the
Home screen.
G. Automatic Mode—Touch the Automatic Mode button to initialize the machine for automatic operation.
4.1.4.
The Recovery Sequence
This machine performs a recovery sequence at power-up to put certain components in their default positions. The default position may vary depending on how the laundry system surrounding this machine operates, but it is similar to this:
1. The elbow moves to the up and locked position.
2. The loading/discharge door opens fully.
3. The machine tilts to the rear fully down position.
4. The controller prompts, "Is there a load in the machine?" See
Figure 47: Machine Loaded Prompt
• If the machine does not have a load, it starts automatic operation at State 00 (see
Figure 48: State 00 Window
• If the machine has a load, the controller prompts whether the machine was loading or discharging when automatic operation was interrupted.
• The controller prompts the operator to enter the batch data for the goods in the machine.
PELLERIN MILNOR CORPORATION
55
Chapter 4. Automated Loading and Discharge Information
» If the machine was interrupted after loading but before the goods were washed:
1. The loading/discharge door closes fully.
2. The machine tilts to the wash position.
3. The controller starts the required formula.
» If the machine was interrupted after washing but before the goods were discharged:
1. The machine tilts to the rear fully up position.
2. The controller starts the discharge sequence.
— End of BICLDO01 —