Whirlpool WHES40 Installation and Operation Manual
Below you will find brief information for Water Softener WHES40. This manual provides instructions on installation, operation, and maintenance of your demand-controlled water softener. It covers topics like water conditioning, installation requirements, programming, and troubleshooting. The document includes safety information and detailed diagrams to help you set up and maintain your system.
Advertisement
Advertisement
Model WHES40
How to install, operate and maintain your Demand
Controlled Water Softener
Do not return water softener to store
If you have questions or concerns when installing, operating or maintaining your softener, call our toll free number:
1-866-986-3223
Monday - Friday, 8 am - 9 pm EST
Click in this page to return to
water softener information
at
InspectApedia.com
TM
7262970 (Rev. D 9/22/04)
Product No. 8562922
Table of Contents
Water Softener Safety ..........................................................................
Before You Start ...............................................................................
Inspect Shipment ..............................................................................
Water Softener Dimensions .....................................................................
How a Water Softener Works ....................................................................
Softening Cycle ............................................................................
Regeneration Cycle .........................................................................
Water Conditioning Information ..................................................................
Water Conditioning .........................................................................
Installation Requirements .......................................................................
Location Requirements ......................................................................
Tools and Parts Needed .....................................................................
Air Gap Requirements ......................................................................
Valve Drain Requirements ...................................................................
Plan the Installation ............................................................................
Inlet - Outlet Plumbing Options ..............................................................
Installation Instructions .........................................................................
Turn Off Water Supply .......................................................................
Install Brine Tank Overflow Elbow .............................................................
Move the Water Softener into Place ...........................................................
Assemble Inlet and Outlet Plumbing ..........................................................
Connect Inlet and Outlet Plumbing ...........................................................
Install Valve Drain Hose .....................................................................
Install Salt Storage Tank Overflow Hose .......................................................
Test for Leaks ..............................................................................
Add Water and Salt to the Salt Storage Tank ...................................................
Sanitize the Water Softener!Sanitize
After Service ...............................................
Plug In the Water Softener ...................................................................
Program the Water Softener .....................................................................
Set Time of Day ............................................................................
Set Water Hardness Number .................................................................
Set Recharge (Regeneration) Time ...........................................................
Set Salt Type ...............................................................................
Start a Recharge ...........................................................................
Customize Features/Options ....................................................................
Recharge ..................................................................................
Recharge Scheduled / Tonight ...............................................................
Set Salt Level ..............................................................................
Tank Light .................................................................................
Timer "Power-Outage Memory" . ............................................................
Water Flow Indicator ........................................................................
Salt Efficiency ..............................................................................
Clean / Clear Water Iron Removal ............................................................
Clean Feature Minutes ......................................................................
Maximum Days Between Regenerations .......................................................
12 or 24 Hour Clock ........................................................................
Routine Maintenance ...........................................................................
Refilling With Salt ...........................................................................
Breaking A Salt Bridge ......................................................................
Cleaning the Nozzle and Venturi ..............................................................
Troubleshooting Guide .........................................................................
Automatic Electronic Diagnostics .............................................................
Manual Advance Diagnostics ................................................................
Manual Advance Regeneration Check ........................................................
Wiring Schematic ..............................................................................
Warranty ......................................................................................
Softener Components ..........................................................................
3
3
9
8
10
10
11
11
11
12
6
6
8
8
8
4
5
5
5
5
13
13
14
20
20
20
20
21
21
17
17
18
19
19
19
19
14
15
15
15
15
16
16
17
22
22
23
26
26
27
29
29
30
23
23
24
25
Water Softener Safety
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This symbol alerts you to potential hazards that can kill or hurt you and others.
This is the safety alert symbol.
or
"WARNING." These words mean:
You can be killed or seriously injured if you don't immediately follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
For installations in the Commonwealth of Massachusetts:
Installation by a licensed plumber is required.
Plumbing code 248-CMR of the Commonwealth of Massachusetts must be used for installation.
For installations in the state of California:
You must turn the Salt Efficiency Feature setting to ON. This may initiate more frequent recharges, however, it will operate at 4,000 grains per pound of salt or higher. To turn on the Salt
Efficiency Feature, t_llow the instructions in the "Salt Efficiency" section of this manual.
Before You Start
See "Location Requirements" section before installing water softener.
Follow the installation instructions carefully.
(Failure to install the water softener properly voids the warranty.)
Befk_re you begin installation, read this entire manual. Then, obtain all the materials and tools you will need to make the installation.
Check local plumbing and electrical codes.
Use only lead-flee solder and flux for all sweat-solder connections, as required by federal codes.
Use care when handling the water softener. Do not turn upside down, drop, or set on sharp protrusions.
Avoid installing in direct sunlight.
Excessive sun heat may cause distortion or other damage to non-metallic parts.
The water softener requires a minimum water flow of 3 gallons per minute at the inlet. Maximum allowable inlet water pressure is 125 psi. If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum.
Use a pressure reducing valve if necessary.
(Adding a pressure reducing valve may reduce the flow.) If your home is equipped with a back flow preventer, an expansion tank must be installed in accordance with local codes and laws.
The water softener works on 24 volt-60 hz electrical power only, supplied by a direct plug-in transformer (included).
Be sure to use the included transfk_rmer and plug it into a nominal 120V, 60 cycle household outlet that is properly protected by an overcurrent device such as a circuit breaker or fuse. If transtk_rmer is replaced, use only the authorized service, Class II, 24V 10VA transformer.
This system is not intended to be used for treating water that is microbiologically unsafc or of unknown quality without adequate disinfection befi)re or after the system.
Inspect Shipment
The parts required to assemble and install the water softener are included with the water softener.
Single valve bypass 20 ft. green drain hose Copper tubes and ground clamp
%
Hose adaptor Hose clamps Copper reducer tubes
Drain line adaptor Clips O-rings
Grommet
Water hardness test strip
I ]
Thoroughly check the water softener tk)r possible shipping damage and parts loss. Also inspect and note any damage to the shipping carton.
Remove and discard (or recycle) all packing materials.
To avoid loss of small parts, we suggest you keep the small parts in the parts bag until you are ready to use them.
Do not return the water softener to store.
If you have any questions, or there are missing parts or damage, please call
1-866-986-3223, Monday Friday, 8 am - 9 pm EST.
Before you call please have your model number, date of purchase, water conditions and number of people living in your home.
Model No. O O
Code O
*Water hardness
For future reference, enter the following information.
gpg
Serial No. O O
Installation date
**Iron content ppm
O on registration decal (located under salt hole cover) O on shipping carton
A hardness test strip is provided with your water sot'tener.
"_* Kits are available at retail hardware stores tk_rtesting water hardness and iron content. Some retail stores will also test your water tk_ra fee.
Water Softener Dimensions
,=_ 19"
Lt c
]FOUl_
18"
C
MODEL
WHES40
NOMINAL RESIN TANK SIZE
10" DIA. X 40"
A
41-1/2"
How a Water Softener Works
Softening Cycle
When the water softener is providing soft water, it is called "service" or the "softening cycle". During this cycle, hard water flows from the main water pipe in the household into the water softener. Inside the resin tank is a bed made up of thousands of tiny, plastic resin beads. As hard water passes through the bed, each bead attracts and holds the hardness minerals. Water without the hardness minerals (soft water) flows from the water softener to the rest of the house.
Regeneration Cycle
Eventually the beads become coated with calcium or magnesium ions. At this point, the water softener needs to replenish the beads with sodium ions. This process is called "regeneration".
Regeneration occurs when the resin beads are washed with a strong salt water solution. The sodium forces the calcium and magnesium ions to be released where they are then discharged as waste during the regeneration cycle. The beads are then ready to once again collect the hardness minerals (calcium and magnesium) from the water. Regeneration consists of five cycles; brine fill, brining, brine rinse, backwash and fast rinse. The total time of the regeneration cycle is approximately two hours.
Water Conditioning Information
Water Conditioning
Water conditioning is the treatment of four general conditions.
These are:
Hardness
Iron
Acidity
Sediments
1.
Hardness is a term to describe the presence of calcium and magnesium minerals in water. A chemical analysis accurately measures the amount of minerals in grain weight. For example, one gallon of water with 5 grains per gallon (gpg) hardness has dissolved minerals, that if solidified, about equals the size of one ordinary aspirin tablet. One gallon of water, 25 gpg hard, has a mineral content equal in size to 5 aspirin tablets.
Water hardness varies greatly across the country.
It generally contains from 3 to 100 gpg.
Hardness minerals combine with soap to make a soap curd. The curd greatly reduces the cleaning action of soap. Precipitated hardness minerals form a crust on cooking utensils, appliances, and plumbing fixtures.
Even the tastes of foods are affected. A water softener removes the hardness minerals to eliminate these effccts, and others.
IMPORTANT: Water softeners using sodium chloride (salt) for regeneration add sodium to the water. Persons on sodium restricted diets should consider the added sodium as part of their overall intake. Water softeners using potassium chloride (salt) for regeneration add sodium to the water.
Persons on potassium restricted diets should consider the added potassium as part of their overall intake.
Factor into your diet the amount of sodium or potassium shown below, based on your water hardness and consumption.
Initial Water Hardness
Grains per Gallon
1
5
10
15
20
30
8
9
6
7
40
Sodium Added to Water from Cation Exchange Softening
Sodium added by Cation
Exchange Softening of Water*
Milligrams Na+/qt.
7.5
37
75
112
150
225
44
52
60
68
300
Potassium added by Cation
Exchange Softening of Water**
Milligrams K+/qt.
12.75
62.9
74.8
88.4
102
115.6
127.5
190.4
255
382.5
510
*If your water supply is 15 grains hard and you drank 3 quarts of softened water you would consume 335 milligrams of sodium. That is equivalent to eating 2-1/2 slices of white bread.
**One large banana, about 9 inches in length, has approximately 600 milligrams of potassium.
2_
3_
4_
Iron in water can cause stains on clothing and plumbing fixtures.
It can negatively affcct the taste of tk)od, drinking water, and other beverages.
Iron in water is measured in parts per million (ppm).
The total* ppm of iron, and type or types*, is determined by chemical analysis. Four different types of iron in water are:
Ferrous (clear water),
Ferric (red water),
Bacterial and organically bound iron,
Colloidal and inorganically bound iron (fcrrous or fcrric).
*Water may contain one or more of the four types of iron and any combination of these. Total iron is the sum of the contents.
Ferrous (clear water) iron is soluble and dissolves in water.
This water softener will remove moderate amounts of this type of iron (see specificatkms).
Ferrous (clear water) iron is usually detected by taking a sample of water in a clear bottle or glass. Immediately after taking, the sample is clear.
As the water sample stands, it gradually clouds and turns slightly yellow or brown as air oxidizes the iron. This usually occurs in 15 to 30 minutes.
When using the softener to remove Ferrous (clear water) iron, add 5 grains to the hardness setting for every t ppm of Ferrous (clear water) iron. See "Set Water Hardness Number" section.
Ferric (red water), and bacterial and organically bound irons are insoluble.
This water softener will not remove fcrric or bacterial iron. This iron is visible immediately when drawn from a faucet because it has oxidized before reaching the home.
It appears as small cloudy yellow, orange, or reddish suspended particles.
After the water stands tk_r a period of time, the particles settle to the bottom of the container.
Generally these irons are removed from water by filtration.
Chlorination is also recommended for bacterial iron.
Colloidal and inorganically bound iron is of fcrric or fcrrous form that will not filter or exchange out of water.
This water softener will not remove colloidal iron. In some instances, treatment may improve colloidal iron water.
Colloidal iron water usually has a yellow appearance when drawn.
After standing for several hours, the color persists and the iron does not settle, but remains suspended in the water.
Acidity or acid water is caused by carbon dioxide and hydrogen sulfide.
This water softener will not improve an acid condition in water.
Acid water can be corrosive to plumbing, plumbing fixtures, water heaters, and other water using appliances.
In can also damage and cause premature failure of seals, diaphragms, etc., in water handling equipment.
A chemical analysis is needed to measure the degree of acidity in water.
This is called the pH of water.
Water testing below 6.9 pH is acidic.
The lower the pH reading, the greater the acidity.
A neutralizer filter or a chemical teed pump are usually recommended to treat acid water.
Sediment is fine, foreign material particles suspended in water.
This water softener will not remove sediment.
This material is most often clay or silt. Extreme amounts of sediment may give the water a cloudy appearance.
A sediment filter installed ahead of the water softener normally corrects this situation.
Installation Requirements
Tools and Parts Needed
Assemble the required tools before starting installation.
Read and %llow tile instructious provided with any tools listed here.
• Screwdriver
• Pliers
• Tape Measure
If using Soldered Copper Pipe
• Tubing cutter
• Propane torch
• Misc. copper pipe fittings
If using Threaded Pipe
• Pipe cutter or hacksaw
• Threading tool
If using CPVC Plastic
• Pipe cutter
• Hacksaw
• Adjustable wrench
• Lead-free solder and flux
* Emery cloth, sandpaper or steel wool
• Pipe joint compound
* Misc. threaded pipe fittings
* Solvent cement
• Primer
• Misc. CPVC pipe fittings
If using Other
• Other pipe and fittings suitable %r potable water supply as required by piping system manufacturer and local codes and/or ordinances.
Location Requirements
Consider all of tile %llowing when selecting all installation location for tile water softener.
• Do not locate the water softener where freezing temperatures occur. Do not attempt to treat water over 120°E Freezing, or hot water damage voids the warranty.
• To condition all water in the home, install the water softener close to the water supply inlet, and before all other plumbing connections, except outside water pipes. Outside faucets should remain on hard water to avoid wasting conditioned water and salt.
• A nearby drain is needed to carry away regeneration discharge (drain) water. Use a floor drain, laundry tub, sump, standpipe, or other options (check your local codes). See "Air
Gap Requirements" and "Valve Drain Requirements" sections.
• The water softener works on 24 volt-60 hz electrical power only, supplied by a direct plug-in trans%rmer (included).
Provide an electrical outlet in accordance with NEC and local codes.
• Always install the water softener between the water heater and water inlet. Any other installed water conditioning equipment should be installed between the water softener and the water inlet (see Figure 1 below).
cold t_ '_
I water heater_ optional sediment filter waterinlet water
softener I I
Figure 1
Air Gap Requirements
A drain is needed for regeneration discharge water. A floor drain, close to the water softener, is preferred.
A laundry tub, standpipe, etc., are other drain options. Secure valve drain hose in place.
drain drain hose j drain hose iose t-1/z' \\ airgap \\ floor drain
] I I
standpipe
1- 1/2" airgap y
1-1/z' \ a)rgap laundry tub
Figure 2
Valve Drain Requirements
Use the flexible green drain hose, that is included, measure and cut to the length needed. Flexible drain hose is not allowed in all localities (check your plumbing codes). If local codes do not allow use of a flexible drain hose, a rigid valve drain run must be used. Buy a compression fitting (garden hose threads x 1/2 in. minimum tube) and 1/2" tubing from your local hardware store. Then plumb a rigid drain as needed (see Figure 3).
NOTE: Avoid long drain hose runs, or elevating the hose more than 8' above the floor. Make the water softener valve drain as short and direct as possible.
valve drain elbow adaptor, garden hose type thread x compression (not provided) clip t
1/2" I.D.
(minimum) copper tube (not provided)
Figure 3
Plan the Installation
Inlet - Outlet Plumbing Options
Always install either a single bypass valve (provided) or, if desired, parts tk)r a 3 valve bypass system
(not included) can be purchased and assembled, as shown in Figure 4. Bypass valves allow you to turn off water to the softener tk_rmaintenance if needed, but still have water in house pipes.
Single valve bypass 3 valve bypass
,, I pull out for service/soft water push in for bypass valve outlet _ valve valve
_ inlet from to water softener water softener
Figure 4 hard water to outside _faucets water softener valve
• Pipe and fittings must be 3/4" minimum.
Use either:
• Copper pipe
• CPVC plastic pipe conditioned water
_" direct plug-in transformer grounding clamp
• Threaded pipe
• Other pipe approved for use with potable water clips I iS
U
1"
1"pipe coupling grounding
_to timer inlet tube
o-r,ng
valve drain elbow drain elbow valve drain hose *
* Do not connect the water softener valve drain tubing to the salt storage tank overflow hose.
floor drain
Figure 5 (typical installation) lubricated o-ring overflow hose * single valve bypass
To keep over floor drain, secure valve drain hose in place.
NOTE:
NOTE:
See "Air Gap Rcqmrements 7,
Shown with salt hole cover and top cover removed.
lO
Installation Instructions
Turn Off Water Supply
1.
Close the main water supply valve, near the well pump or water meter.
2.
Open all faucets to drain all water from the house pipes.
NOTE: Be sure not to drain water from the water heater, as damage to the water heater elements could result.
Install the Brine Tank Overflow Elbow
Install the brine tank overflow grommet and elbow in the 13/16" diameter hole in the back of the salt storage tank sidewall.
NOTE: The brine tank overflow elbow accepts either 1/2" or 3/8" I. D. hose.
Top cover
Nozzle venturi assembly
Brine tank overflow elbow
Nut-ferrule
Salt hole cover
Brine tubing
Brine tank overflow grommet
13/16" hole
Salt storage tank
Stand tube
Brinewell cover
Brinewell stem
Brine valve
Figure 6 li
Move the Water Softener into Place
Excessive Weight Hazard
Use two or more people to move and install water softener.
Use two or more people to move and lift salt bags.
Failure to do so can result in back or other injury.
1.
Move the water softener into desired location. Set it on a level surface. If needed, place the water softener on a section of plywood, a minimum of 3/4" thick. Then, shim under the plywood to level the water softener, see Figure 7.
IMPORTANT: Do not place shims directly under the salt storage tank. The weight of the tank, when full of water and salt, may cause the tank to fracture at the shim.
12
Plywood
Shim i ,,
Figure 7 (if needed tk)r leveling)
2.
Visually check and remove any debris from the water softener valve inlet and outlet ports.
3.
If not already done, put a light coating of silicone grease or petroleum .idly on the single valve bypass o-rings.
4.
Push the single valve bypass into the softener valve as far as it will go. Snap the two large holding clips into place, from the top down as shown in Figure 8.
IMPORTANT: Be sure the clips snap firmly into place so the single valve bypass will not pull out.
correct assembly lie valve bypass outside clip __ diameter of water softener valve inlet and outlet outside diameter of clip channel on single valve bypass
NOTE: Be sure all 3 tabs of the clip go through the matching holes on the water softener valve inlet or outlet, and fully into the channel on the single valve bypass.
Figure 8
Assemble Inlet and Outlet Plumbing
Measure, cut, and loosely assemble pipe and fittings from the main water pipe to the inlet and outlet ports of the water softener valve. Be sure to keep fittings fully together, and pipes squared and straight.
Be sure hard water supply pipe goes to the water softener valve inlet side.
NOTE: Inlet and outlet are marked on the water softener valve. Trace the water flow direction to be sure hard water is to inlet.
IMPORTANT: Be sure to fit, align and support all plumbing to prevent putting stress on the water softener valve inlet and outlet. Undue stress from misaligned or unsupported plumbing may cause damage to the valve.
Connect Inlet and Outlet Plumbing
Complete the inlet and outlet plumbing for the type of pipe as shown below.
Electrical Sl_ock H_ard
Use metal fittings with metal pipe.
Do not use plastic fittings to connect to metal house pipes.
Failure to follow these instructions can result in death or electrical shock.
Ground Clamp _
U U
_!Gou
rn dClamp
Figure 9
Soldered copper
1.
Thoroughly clean and apply solder flux to all joints.
2.
Make all solder connections.
NOTE:
IMPORTANT:
Do not solder with installation tubes attached to single valve bypass. Soldering heat will damage the valve.
When installing the copper tubes and ground clamp assembly to the single valve bypass, the ground clamp must be secured in place. If necessary tighten the screw.
I3
Threaded pipe
1.
Apply pipe joint compound or Teflon ® tape to all male pipe threads.
2.
Tighten all threaded joints and make all solder connections.
NOTE: Do not solder with installation will damage the valve.
tubes attached to single valve bypass. Soldering heat
IMPORTANT: When installing the copper tubes and ground clamp assembly to the single valve bypass, the ground clamp must be secured in place. If necessary tighten the screw.
CPVC plastic pipe
1.
Clean, prime and cement all joints, following the malmfacturer's instructions supplied with the plastic pipe and fittings.
NOTE: Do not solder with installation will damage the valve.
tubes attached to single valve bypass. Soldering heat
IMPORTANT: When installing the copper tubes and ground clamp assembly to the single valve bypass, the ground clamp nmst be secured in place. If necessary tighten the screw.
Other
1.
Follow the piping system manufacturer's instructions when using other pipe approved for potable water.
IMPORTANT: When installing the copper tubes and ground clamp assembly to the single valve bypass, the ground clamp nmst be secured in place. If necessary tighten the screw.
Install Valve Drain Hose
1.
Measure, cut to needed length and connect the 3/8" green drain line (provided) to the water softener valve drain fitting. Use a hose clamp to hold the hose in place.
IMPORTANT: If codes require a rigid drain line see "Valve Drain requirements" section.
2.
Run the green drain hose or copper tubing to the floor drain. Secure green drain hose. This will prevent "whipping" during regenerations.
See "Air Gap Requirements" section.
Install Salt Storage Tank Overflow Hose
1.
Measure, cut to needed length and connect the 3/8" green drain line (provided) to the salt storage tank overflow elbow and secure in place with a hose clamp.
2.
Run the hose to the floor drain, or other suitable drain point no higher than the &ain fitting on the salt storage tank. (This is a gravity drain.) If the tank overfills with water, the excess water flows to the drain point. Cut the green drain line to the desired length and route neatly out of the way.
IMPORTANT: For proper operatkm of the water softener, do not connect the water softener valve drain tubing to the salt storage tank overflow hose.
14
Test for Leaks
To prevent air pressure in the water softener and plumbing system, do the %llowing steps in order.
1.
Fully open two or more softened cold water faucets close by the water softener, located downstream from the water softener.
2.
Place the single valve bypass valve or 3 valve bypass in "bypass" position.
See "Plan The
Installation" section.
3.
Fully open the main water supply valve. Run water until there is a steady flow from the opened faucets, with no air bubbles.
4.
Place bypass valve(s) in "service" or soft water position as follows:
• Single valve bypass: Slowly move the valve stem toward %ervice", pausing several times to allow the water softener to fill with water.
• 3 valve bypass: Fully close the bypass valve and open the outlet valve. Slowly open the inlet valve, pausing several times to allow the water softener to fill with water.
5.
After about three minutes, open a hot water faucet until there is a steady flow and there are no air bubbles, then close.
6.
Close all cold water faucets and check for leaks at the plumbing connections that you made.
Add Water and Salt to the Salt Storage Tank
Excessive Weight Hazard
Use two or more people to move and install water softener.
Use two or more people to move and lift salt bags.
Failure to do so can result in back or other injury.
l.
Using a container, add about three gallons of clean water into the salt storage tank.
2.
Fill the salt storage tank with salt. Use nugget, pellet or coarse solar salts with less than 1% impurities.
NOTE: See "Routine Maintenance Section" for additional information on salt.
Sanitize the Water Softener/Sanitize After Service
t.
Open salt hole cover and remove the brinewell cover and pour about t- 1/2 oz. (2 to 3 tablespoons) of household bleach into the softener brinewell.
Replace the brinewell cover.
2.
Make sure the bypass valve(s) is in the service (open) position.
3.
Sanitize procedure will be completed when first cycle is run and sanitizing solution is flushed from the water softener.
Plug in Water Softener
During installation, the water softener wiring may be moved or jostled from place. Check to be sure all leadwire connectors are secure on the back of the electronic board and be sure all wiring is away from the valve gear and motor area, which rotates during regenerations.
t.
Plug the water softener into an electrical outlet that is not controlled by a switch.
NOTE: The water heater is filled with hard water and, as hot water is used, it refills with conditioned water. In a few days, the hot water will be tully conditioned.
To have tully conditioned hot water immediately, wait until the initial recharge is over. Then, drain the water heater (following instructions for water heater) until water runs cold.
I5
Program the Water Softener
SET SALT LEVEL button Display
/
UP button
TANK LIGHT button
_ECHARGE
TRESS TO SCHEDULE
HOLD TO START
GRAM
RECHARGE button
Figure 10
/
PROGRAM button
\
DOWN Button
If you have questions about installation, programming, operating and routine maintenance...
call 1-866-986-3223, Monday - Friday, 8 am to 9 pm, EST.
J
When the water softener is plugged in, a model code and a test number (example: J1.0), begin to flash in the faceplate display. Then, "12:00 PM" and the ",w rds
"
CURRENT TIME" begin to flash.
NOTE: If ....
shows in the display, press the UP _ or DOWN _ until LE40 shows in the display. Then, press the O PROGRAM button to set, and change to the flashing "CURRENT TIME" display.
Set Time of Day
If the words "CURRENT TIME" do not show in the display, press the O PROGRAM button until they do.
1.
Press the _ Up or _ sets the time back.
Down buttons to set the present time. Up sets the display ahead; down
U'£O,.
l.gO
C_nt
Time
# m.3c
I /.gO
C_nt
Time
Be sure AM or PM is correct.
NOTE: Press buttons and quickly release to slowly advance the display. Hold the buttons down for fast advance.
This procedure applies for all following settings.
16
Set Water Hardness Number
1.
Press the O PROGRAM button once again to display a flashing 2_ and the w( rd HARDNESS .
c
3
Hardness
A_ W7
2.
Press the _ Up or V Down buttons to set your water hardness number.
NOTE: If your water supply contains iron, compensate for it by adding to the water hardness number. For example, assume your water is 20 gpg hard and contains 2 ppm iron. Add
5 to the hardness number for each 1 ppm of iron. In this example, you would use 30 for your hardness number.
2 ppm iron x 5 =
(times)
10
20 gpg hardness
+10
30 HARDNESS NUMBER
Set Recharge (Regeneration) Time
Press the _ PROGRAM button once again to display a flashing 2:00AM and the words
"RECHARGE TIME". This is a good time for the recharge to start in most households because water is not in use.
2.1-11-1,
.UL!
Time
If you want to change the recharge start time, press the _ desired starting time shows.
Up or V Down buttons until the
Set Salt Type
1.
Press the _ PROGRAM button once again to display a flashing "nACL".
nR&
LL
Salt Type alk)ws you to choose between sodium chloride (NaC1), which is regular softener salt, or potassium chloride (KC1), which is an alternative to sodium chloride. KC1 (potassium chloride) may be used if the user of the water softener is on a sodium restricted diet and is concerned about the amount of sodium in the water supply. See "Water Conditioning hfformation" section.
KC1 should be used in accordance to the following steps to help give you years of maintenance free service.
Place one bag only of KC1 in your softener at a time (the salt storage tank should contain no more than 60 pounds of KC1 at any one time);
NOTE: A softener using KC1 should not be placed in areas with high temperature changes or high humidity (KC1 will harden in these environments and may make the softener inoperable);
I7
2.
Check the brine tank and brinewell (black tube in salt storage tank) monthly.
If hardening is present, pour small amounts of warm water on hardened areas until they loosen;
3.
Be sure to set the correct salt type depending on which salt type is used (NaC1 or KC1).
Use the _ Up or _/ Down buttons to toggle between NaC1 or KC1 and press the O
PROGRAM button to enter information.
4.
Press the O PROGRAM button once again to return to normal operating display.
Start a Recharge
Press the O RECHARGE button and hold for three seconds until Recharge begins to flash in the timer display, starting a recharge.
This recharge draws the sanitizing bleach into and through the water softener. Any air remaining in the water softener is purged to the drain.
If you have questions about installation, programming, operating and routine maintenance...
call 1-866-986-3223, Monday - Friday, 8 am to 9 pm, EST.
18
Recharge
Customize Features/Options
Recharge button is used to initiate an immediate recharge.
Press and hold the O RECHARGE button until the words "RECHARGE", "SERVICE" and "FILL" flash in the display, and the softener enters the fill cycle of regeneration right away.
RECHARGE will flash during the regeneration.
When over, full water conditioning capacity is restored.
While water softener is running a recharge, the time remaining until the recharge is completed will show in the display during all cycles except for the Fill cycle.
RECHARGE Initiated
NOTE:
Avoid using hot water while the conditioner is regenerating, because the water heater will refill with bypass hard water.
Recharge Scheduled
If you do not want to start an immediate recharge, but would like an extra recharge at the next preset recharge time, do the following to schedule a recharge.
• Press and release (do not hold) the O RECHARGE button. The ",wrds
"
RECHARGE
•
SCHEDULED" flash in the display, and the softener will recharge at the next recharge time. The word "RECHARGE" will flash during the regeneration.
When over, full water conditioning capacity is restored.
Set Salt Level
The water softener has a salt monitor indicator light to remind you to refill the storage tank with salt.
NOTE: You must set salt level each time salt is added to the water softener.
To set this monitor system, lift the salt hole cover and level the salt in the storage tank.
The salt level decal, on the brinewell inside the tank, has numbers from 0 to 8. Observe the highest number the leveled salt is at, or closest to. Now, press the O SET SALT
LEVEL button until black ovals correspond to the salt level number. At level 2 or below, the indicator LED will flash "Check Salt Level".
If you want to turn the salt monitor off, press the O SET SALT LEVEL button until
"SALT LEVEL OFF" shows in display.
D.U3,.
!{_.-!3
I9
2O
Tank Light
The softener is equipped with a tank light for viewing the salt level in the brine tank. Push the tank light button on the electronic control once and the tank light will turn on. Pushing the tank light button again will turn the light off. The tank light will automatically turn off after a period of fk)ur minutes if the tank light button is not used to turn it off.
"PowerOutage Memory"
If"electrical power to the water softener is lost, "memory" built into the timer circuitry will keep all settings for up to six hours. While the power is out, the display is blank and the water softener will not regenerate.
When electrical power is restored, the fk)llowing will occur.
You have to reset the present time only if the display is flashing. The HARDNESS and RECHARGE
TIME never require resetting unless a change is desired. Even if the clock is incorrect after a long power outage, the softener works as it should to keep your water soft. However, regenerations may occur at the wrong time of day until you reset the clock to the correct time of day.
NOTE: If the water softener was regenerating when power was lost, it will now finish the cycle.
Water Flow Indicator
Whenever tile softener has water flowing from the outlet port, tile display will show water droplets scrolling down the right hand side of the screen. The faster the water flow, the faster the droplets will flash.
3:
li"
6_ j Droplets indicate water Y flow through softener
Salt Efficiency
When this fcature is ON, the water softener will operate at salt efficiencies of 4000 grains of hardness per pound of salt or higher. (May recharge more often using smaller salt dosage and less water). The softener is shipped in the OFF setting.
1.
Press and hold the O PROGRAM button until the following screen is displayed.
i-i t'11-1
s.,i U UU
Once in this display, press the O PROGRAM button once and one of the fk)llowing two displays is shown.
OF; 1
_"-_"__ Efficiency Icon
2.
Press the _ Up or _ Down buttons to set On or Off. When set to On, the efficiency icon will be displayed in the lower left hand corner of the normal run display.
Clean / Clear Water Iron Removal
This fcature is beneficial on water supplies containing iron and/or high amounts of sediments (sand, silt, dirt, etc.). Default setting is "OFF". When set to "ON", an additional backwash and fast rinse cycle will occur first, preceeding the normal regeneration sequence.
This provides extra cleaning of the resin bed betk)re it is regenerated with the salt brine. To conserve water set this fcature "OFF" if your water supply does not contain iron or sediments.
1.
Press and hold the O PROGRAM button until the tk_llowing screen is displayed.
i-i i'11-1
s_,i_ U ULI
Once in this display, press the O PROGRAM button twice and one of the following two displays is shown. Both displays will show the word "Clean".
fin
C/can
tiff:
C/ean
2.
Press the _ Up or _ Down buttons to set On or Off.
Clean Feature Minutes
To adjust the length of the Clean/Clear Water Iron Removal feature, from t to 15 minutes in length.
To change this cycle time, use the UP button to increase the time, or the DOWN button to shorten the time. If you are using this feature the length of the extra backwash cycle automatically sets to 9 minutes.
1.
Press and hold the O PROGRAM button until the fi_llowing screen is displayed.
i-i1"11-1
s.,i_ U UU
Once in this display, press the O PROGRAM button three times and following display is shown.
q Mil_,
C/can
2.
Press the _ Up or _ Down buttons to set number of minutes.
21
Maximum Days Between Regenerations
The water softener automatically controls regeneration frequency. This provides the greatest operating efficiency, and under most conditions, this fcature should be left in this mode. However, modify this feature if you want to force a regeneration every set number of days. For example, if your water supply contains iron and you want the softener to regenerate at least once every fcw days to keep the resin bed clean, set the display as shown below. Setting is available from 1 to 15 days by using the UP and
DOWN buttons.
NOTE: The softener will recharge on its own if needed, even if it is before the set number of days.
1.
Press and hold the O PROGRAM button until the following screen is displayed.
i-inn
s_,,i_ U UU
Once in this display, press the O PROGRAM button four times and following display is shown.
This is the automatic (default) setting.
22
2.
Press the _
12 or 24 Hour Clock
Up or _ Down buttons to set number of days.
All time displays are shown in standard clock time (1 to 12 PM; and 1 to 12 AM) at the 12 hr default setting. If 24 hour clock displays are desired, f()llow steps below.
1.
Press and hold the O PROGRAM button until the folk)wing screen is displayed.
i-i t'11-1
s_,,i_ U UU
Once in this display, press the (_ PROGRAM button five times and the fl)llowing display is shown.
12br = 2qbr
.
Press the _
Time
12 Hour Clock Initiated
Up or _ Down buttons to set clock.
Time
24 Hour Clock Initiated
If you have questions about installation, programming, operating and routine maintenance...
call 1-866-986-3223, Monday - Friday, 8 am to 9 pm, EST.
Routine Maintenance
Refilling With Salt
Lift the salt hole cover and check the salt storage level frequently.
If"the conditioner uses all the salt bef\)re you refill it, you will get hard water. Until you have established a refilling routine, check the salt every two or three weeks. Always refill if less than 1/3 full. Be sure the brinewell cover is on.
NOTE: In humid areas, it is best to keep the salt storage level lower, and to refill more often.
Recommended Salt: Nugget, pellet or coarse solar salts with less than 1% impurities.
Salt Not Recommended: Rock salt, high in impurities, block, granulated, table, ice melting, ice cream making salts, etc., are not recommended.
Breaking A Salt Bridge
NOTE: If you see more thai1 a few inches of water in the bottom of the tallk, see (Jeanlng the Nozzle and Vcnturi" section.
Sometimes, a hard crust or salt bridge forms in the brine tank. It is usually caused by high humidity or the wrong kind of salt. When the salt bridges, an empty space fk)rms between the water and the salt.
Then, salt will not dissolve in the water to make brine. Without brine, the resin bed does not regenerate and you will have hard water.
If the storage tank is full of salt, it is hard to tell if you have a salt bridge. Salt is loose on top, but the bridge is under it. Take a broom handle, or like tool, hold it next to the water softener, measure the distance from the floor to the rim of the water softener. Then push the broom handle straight down into the salt. If a hard object is felt, it's most likely a salt bridge. Carefully push into the bridge in several places to break it. Do not use any sharp or pointed objects as you may puncture the brine tank.
Push Tool into Salt
Bridge to Break
Pencil
Mark
Broom
Handle
Salt
Salt Bridge
Water Level
Figure 11
23
24
Cleaning the Nozzle and Venturi
A clean nozzle and venturi (see Figure 12) is a must for the conditioner to work properly.
This small water softener creates the suction to move brine from the brine tank, into the resin tank. If it should become plugged with sand, silt, dirt, etc., the conditioner will not work, and you will get hard water.
To get to the nozzle and venturi, remove the top cover. Put the bypass valve(s) into bypass position.
Be sure the water softener is in soft water cycle (no water pressure at nozzle andventuri).
Then, holding the nozzle and venturi housing with one hand, turn off the cap. Do not lose the o-ring seal. Lift out the screen support and screen. Then, remove the nozzle and venturi. Wash the parts in warm, soapy water and rinse in fresh water. If needed, use a small brush to remove iron or dirt. Do not scratch, misshape, etc., surfaces of the nozzle and venturi.
Also, check and clean the gasket and flow plug(s).
Replace all parts in the correct order. Lubricate the ()-ring seal with silicone grease and locate in position. Install and tighten the cap, by hand only. Do not overtighten and break the cap or housing.
Put the bypass valve(s) into service/soft water position.
cap@
O-ring seal -----"--_O
Screen support -..___.__@
Nozzle &
Screen ...._..__ _ venturi
Gasket
*Flow plug (HVDC)
Nozzle & venturi housing
*Flow plug
(DUDC or DDUC)
Screen
*Install with lettered side up concave side down.
Ferrule Nut
IMPORTANT: Be sure small hole in the gasket is centered directly over the small hole in the nozzle & venturi housing.
Figure 12
Recharge the softener several times to reduce water level in the tank. This will also assure that the softener is completely recharged and ready to provide softened water again. Once the water level in
3" ) of recharges, do the following:
Remove the brine valve assembly from the brinewell and push float stem down. Place opening of brine valve just under the water and start a recharge.
Move the brine valve down with each recharge, until it rests at the bottom of the tank. Add salt, if needed, and return to normal use.
F
Brine valve assembly is inside the brinewell, located in the salt storage tank.
_
_)_ Float stem
(push down)
Figure 13
If"you have questions about routine maintenance...
call 1-866-986-3223, Monday - Friday, 8 am to 9 pm, EST.
Troubleshooting Guide
Need help troubleshooting?
(?all 1-866-986-3223, Monday - Friday, 8 am to 9 pm, EST.
PROBLEM
No Soft Water
No Soft Water Timer
Display Blank
No Soft Water Salt Level
Not Dropping
No Soft Water, Salt
Storage Tank Full Of
Water
Water Hard Sometimes
Iron In Water
Motor Stalled Or Clicking
Error Code Et, E3, or E4 appears
Error Code E5 appears
Tools Needed For Most Repairs: 5/16 Hex Driver, Phillips Screwdriver, Needle-nose Pliers
CAUSE SOLUTION
1.
No salt in the storage tank.
a.
Refill with salt.
b.
Use Recharge feature.
a.
Check for loss of power and correct.
Reset electronic controls and use the Recharge feature.
1. Transformer unplugged at wail outlet, or power cable disconnected from back of electronic board, transformer defective.
2.
Fuse blown, circuit breaker popped, or circuit switched off.
(See page 20 "Power Outage Memory").
3.
Electronic control board defective,
1. Salt in storage tank bridged,
2.
Manual bypass valve(s) in bypass position,
1.
Dirty, plugged or damaged nozzle & venturL
2.
Valve drain hose plugged,
3.
Low or high system water pressure (low pressure may disrupt brine draw during recharge, high pressures may cause inner valve parts failure),
4.
Brine valve float dirty or defective,
5.
Leak between valve and resin tank assembly, t.
Time setting wrong,
2.
Incorrect water hardness setting,
3.
Incorrect model code programmed,
4.
Hot water being used when softener is regenerating,
5.
Possible increase in water hardness,
6.
Leaking faucet or toilet valve. Excessive water usage, t.
Clear water iron in water supply,
2.
Iron in soft water,
3.
Bacterial or organic bound iron.
t.
Motor defective or inner valve defect causing high torque on motor,
1. Wiring Harness or Connection to Position Switch.
2.
Switch,
3. Valve Defect Causing High Torque.
4.
Motor Inoperative
1.
Electronic Control.
a.
Replace fuse, reset circuit breaker, or switch circuit on use the
Recharge feature.
a.
Replace Electronic Control Board (PWA). * a.
Refer to "Breaking a Salt Bridge" section to break.
a.
Move stem in single valve bypass to service.
a. Take apart, clean and inspect nozzle and venturi, see
"Cleaning the Nozzle and Venturi" section.
a.
Hose must not have any kinks, sharpbendsoranywaterflow blockage, see "Valve Drain Requirements" section.
a.
If pressure is low, increase well pump output to a minimum 20 psi. Add a pressure reducing valve in the supply pipe to the softener, if daytime pressure is over 100 psi. Contact a licensed plumber.
a.
Clean or replace Brine Valve Float assembly.
* a.
Replace o-rings between resin tank and valve. See water softener components.
a.
Check and change time setting.
a.
Refer to "Set Water Hardness Number" section to set correctly.
a.
Refer to "Program The Water Softener" section to set correctly.
a. Avoid using hot water while the softener is regenerating as the water heater will fill with hard water.
a. Testtherawwaterforhardnessandironandprogramthe water softener accordingly, see "Set Water Hardness Number" section to set.
a. A small leak will waste hundreds of gallons of water in a few days. Fix all leaks and always fully close faucets.
a. Test the raw water for hardness and iron and program the water softener accordingly see "Set Water Hardness Number" section to set.
a.
Clean resin bed with Resin Bed Cleaner. Follow instructions on package.
a.
Cannot be treated by water softener.
a.
Replace rotor/seal kit.* b.
Replace motor & switch. See water softener components.
a.
Replace wiring harness or connection to position switch. See water softener components.
a.
Replace switch. See water softener components, a.
Replace rotor/seal kit.* a.
Replace motor. * a.
Replace Electronic Control Board (PWA), *
Assistance from customer service may be needed with the fl)llowing problems and solutions.
PROBLEM
Water Running To The
Drain (While Unit Is In The
Soft Water Cycle)
Resin In Household
Plumbing,
Leaking
Resin Tank
Salt Storage Tank Leaking
CAUSE t.
Inner valve defect causing leak.
1.
Crack in distributor or riser tube.
a.
Replace seals and rotor,
SOLUTION a.
RepIace distributor or risertube.
1.
Crack in brine tank.
a.
Replace salt storage tank.
Instructions included.
Procedure fl)r removing error code from faceplate:
1.
Unplug transfk_rmer from outlet.
2.
Correct defect.
3.
Plug in transfk_rmer.
4.
Wait for 6 minutes.
The error code will return if the defect was not corrected.
25
26
Automatic Electronic Diagnostics
This water softener has a self-diagnostic function for the electrical system (except input power and/or water meter). The water softener monitors electronic components and circuits for correct operation.
If a malfunction occurs, an error code appears in the display.
The troubleshooting chart shows the error codes that could appear, and the possible malfunctions for each code.
While an error code appears in the display, all buttons are inoperable except the PROGRAM button.
PROGRAM remains operational so the service person can perform the Manual Advance Diagnostics, see below, to further isolate the problem.
Manual Advance Diagnostics
Use the following procedures to advance the water softener through the regeneration cycles to check operation.
Lift off the Salt Hole Cover, remove the top cover by unlocking the tabs in the back and rocking forward, to observe cam and switch operation during valve rotation.
1.
Press and hold (_ PROGRAM for 3 seconds until 000 - - shows in the display.
i-it"11-1
s_,i_ U UU
2.
The first 3 digits indicate water meter operation as folk)ws:
000 (steady) = Soft water not in use, and no flow through the meter.
Open a nearby soft water faucet.
000 to 140 (continual) = Repeats display for each galkm of water passing through the meter.
NOTE: If you don't get a reading in the display, with faucet open, pull the sensor from the valve outlet port. Pass a small magnet back and forth in front of the sensor. You should get a reading in the display. If you get a reading, unhook the in and out plumbing and check the turbine for binding.
/ /-Zmoto sensor housing position switch _-_(
J iI turbine turbine support & shaft
3.
valve outlet
Symbols in the display indicate POSITION switch operation.
Switch is open i-i1"11-1
,,11i# UL, L, i-i1"11-11
"11;# U|JL' I_ Switch is closed
.
(cam not rotating) I-''"_._-
L
.._.__
(Cam rotating)
Use the O RECHARGE button to manually advance the valve into each cycle and check correct switch operation.
NOTE:
5.
Be sure water is in contact with the salt, and not separated by a salt bridge.., see
"Breaking A Salt Bridge" section.
While in this diagnostic screen, the following information is available and may be beneficial for various reasons. This information is retained by the computer from the first time electrical power is applied to the face plate.
6.
a.
Press _ applied.
Up to display the number of days this electronic control has had electrical power b.
Press _ Down to display the number of regenerations initiated by this electronic control since the LEcode number was entered.
Press and hold the _ PROGRAM button until LE40 shows in the display.
7.
This code identifies the softener model. If the wrong number shows, the softener will operate on incorrect programming.
Return the present time display -- Press the _ PROGRAM button.
8.
To change LE number -- Press the _ Up or _ Down button until the correct code shows.
Then, press the O PROGRAM button to return to the present time display.
Manual Advance Regeneration Check
This check verifies proper operation of the valve motor, brine tank fill, brine draw, regeneration flow rates, and other controller functions.
Always make the initial checks, and the manual initiated diagnostics.
NOTE: The dectronic control display must show a steady time (not flashing). If an error code shows, first press the _ PROGRAM button to enter the diagnostic display.
1.
Press the (_) RECHARGE button and hold in tk)r 3 seconds.
RECHARGE begins to flash as the softener enters the fill cycle of regeneration.
Remove the brinewell cover and, using a flashlight, observe fill water entering the tank.
If water does not enter the tank, look tk)r an obstructed nozzle, venturi, fill flow plug, brine tubing, or brine valve riser pipe.
2.
After observing fill, press the (_ RECHARGE button to move the softener into brining. A slow flow of water to the drain will begin. Verify brine draw from the brine tank by shining a flashlight into the brinewdl and observing a noticeable drop in the liquid level. This may take 15 to 20 minutes to notice.
NOTE: Be sure water is in contact with the salt, and not separated by a salt bridge.., see
"Breaking A Salt Bridge" section.
If the water softener does not &aw brine, check for (most likely to least likely)
• Dirty or plugged nozzle and venturi, see "Cleaning the Nozzle and Vcnturi" section
• Nozzle and venturi not seated on the gasket, or gasket deformed
• Restriction in valve drain, causing a back-pressure (bends, kinks, elevated too high, etc.), see "Install Valve Drain Hose" section.
• Obstruction in brine valve or brine tubing
• Inner valve failure (obstructed outlet disc, wave washer deformed, etc.)
27
NOTE: If water system pressure is low, an elevated drain hose may cause back pressure, stopping brine &aw.
3.
Again, press the O RECHARGE button to move the softener into backwash.
Look Ik)ra fast flow of water from the drain hose.
An obstructed flow indicates a plugged top distributor, backwash flow plug, or drain hose.
4.
Press the O RECHARGE button to move the softener into fast rinse. Again look for a fast drain flow. Allow the softener to rinse Ik)r a few minutes to flush out any brine that may remain in the resin tank from the brining cycle test.
5.
To return the softener to service, press the O RECHARGE button.
Product Specifications
Rated Service Flow Rate (gpm)
Amount of High Capacity Resin (cu ft)
Pressure Drop at Rated Service Flow (psig)
Water Supply Max. Hardness (gpg)
Water Supply Max. Clear Water Iron (ppm)
Water Pressure Limits (min./max. psi)
Min. - Max. Water Temperature (°F)
Min. Water Supply Flow Rate (gpm)
Max. Drain Flow Rate (gpm)
Salt storage capacity
WHES40
12
1.17
11
125
10
20 - 125
40 - 120
3
2.2
200 Ibs.
Performance Claims
Rated Softening Capacity
(Grains/Pounds of Salt)
WHES40
18,000 @ 3.5
30,900 @ 7.0
40,000 @ 11.2
Rated Efficiency (Grains/Pound of Salt @
Minimum Salt Dose) 5,200 @ 3.5 Ibs.
This system conIk)rms to NSF/ANSI 44 Ik)r the specific perR)rmance claims as verified and substantiated by test data.
The efficiency rating is only valid at the stated salt dose. This softener was efficiency rated according to NSF/ANSI Standard 44.
Variable Salt Dose
The salt dose is selected by the electronic controls at regeneration time based on the amount needed.
28
Wiring Schematic
Back of electronic board
Direct plug-in 118 ,, c .-- .--
12 , 124vac
Tank light iii1 ,j o._NO
NC
Position switch
Warranty
WATER SOFTENER WARRANTY
Warrantor: Ecx_dyne Water Systems Inc., 1890 Woodlane Drive, Woodbury, MN 55125
Warrantor guarantees, to the original owner, that:
One Year Full Warranty:
For a period of one (1) year after installation, all parts will be free of defects in materials and workmanship normal functions.
and will perform their
For a period of one (1) year after installation, labor to repair or replace any part deemed to be defective in materials or workmanship, will be provided at no additional cost.
Limited Warranties:
Limited ten (10) year warranty, from date of purchased, the salt storage tank and fiberglass mineral tank will not rust, corrode, leak, burst, or in any other manner, fail to perform their proper functions; and that
Limited three (3) year warranty, after installation, the electronic control board will be free of defects in materials and workmanship and will perform its normal functions.
If, during such respective period, a part proves to be defective, Warrantor will ship a replacement part, directly to your home, without charge.
After the first year, labor necessary to maintain this product is not covered by the product warranty.
If you have questions regarding a warranted product, need assistance with installation or trouble shooting, wish to order a part or report a warranty issue, we are just a phone call away.
Simply dial 1-866-986-3223, Monday - Friday, 8 am - 9 pm EST, for assistance.
General Provisions
The above warranties are effective provided the water conditioner is operated at water pressm'es not exceeding 125 psi, and at water temperatures not exceeding 120°F; provided further that the water conditioner is not subject to abuse, misuse, alteration, neglect, freezing, accident or negligence; and provided further that the water conditioner is not damaged as the result of any unusual fume of nature such as, but not limited to, flood, hurricane, tornado or earthquake.
Warrantor is excused if failure to perform its warranty obligations is the result of strikes, government regulation, materials shortages, or other circumstances beyond its control.
*THERE ARE NO WARRANTIES ON THE WATER CONDITIONER BEYOND THOSE SPECIFICALLY DESCRIBED ABOVE.
ALL IMPLIED WARRANTIES,
PARTICULAR PURPOSE,
THE SOLE OBLIGATION
INCLUDING
ARE DISCLAIMED
OF WARRANTOR
ANY IMPLIED WARRANTY
UNDER THESE WARRANTIES
OF MERCHANTABILITY
IS TO REPLACE
OR OF FITNESS
OR REPAIR
FOR
TO THE EXTENT THEY MIGHT EXTEND BEYOND THE ABOVE PERIODS.
THE COMPONENT
OR PART WHICH PROVES
FOR CONSEQUENTIAL
PERSON IS AUTHORIZED
TO BE DEFECTIVE
OR INCIDENTAL
TO EXTEND
WITHIN
DAMAGES.
OR EXPAND
THE SPECIFIED
NO WARRANTOR
THE WARRANTIES
TIME PERIOD, AND WARRANTOR
DEALER, AGENT, REPRESENTATIVE,
EXPRESSLY DESCRIBED ABOVE.
IS NOT LIABLE
OR OTHER
A
Some states do not allow limitations on how long an implied warranty lasts or exclusions or limitations of incidental or consequential damage, so the limitations and exclusions in this warranty may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. This warranty applies to consumer-owned installations only.
Registered trademark/TM Trademark of Whirlpool, USA, used under license.
(c) 2004 Whirlpool Corporation.
All rights reserved.
TEFLON is a registered trademark of E. I. DuPont.
29
3O
Softener Components
42
27
26
9
11
10
32 -_----_
0
35
35
4O
41
39
12
28
12
13
14
15
16
17
18
19
20
21
22
23
24
Key
No.
6
7
8
9
10
11
3
4
1
2
5
7113016
7131365
7080653
7092252
1205500
0516924
0516211
7170296
7170254
7077870
7170270
7105047
7176292
7088033
7247996
0502272
7171349
7095470
7170288
7092278
7093216
0516947
70972(t2
0513860
Part No.
O-Ring, 2-7/8" x 3-1/4"
O-Ring, 13/16" x 1-1/16"
Top Distributor
O-Ring, 2-3/4" x 3"
Rep'l Bottom Distributor
Clamp Section (2 req.)
Retainer Clip (2 req.)
Rep'l Resin Tank
Resin, 1 cu. tL
Cone Screen
Brine Tube
Tubing Assembly
Screen
Clip
Brine Valve Body
Clip
Bottom Seal Retainer
Seal
O-Ring, 15/16 x 1-3/16
Guide Cap
Float Rod & Stem
Float Seal
Float (includes Key No. 22)
Float Stop
Softener Components
Description
29
30
31
32
41
42
43
44
37
38
39
40
33
34
35
36
Key
No.
25
26
27
28
Part No.
7168647
7116488
7252373
7264914
7267116
7262857
7262661
7163689
7262768
7218696
7082150
7219888
7137824
9003500
1103200
0900431
7262792
7003847
7264883
7248706
7214383
7170262
Description
Ceramic Weight
Rep'l Brine Valve Asm.
Transtbrmer
Rep'l PWA
Top Cover & Faceplate Asm
(order decal, below)
Faceplate Decal
Salt Itole Cover
Vapor Barrier
Rim
Rep'l Light Asm. (includes O-Ring &
Nut)
Nut
Brinewell Cover
Brinewell
Grommet
Ilose Adaptor
Itose Clamp
Screw
O-Ring
Rep'l Brine Tank
Grounding Kit
Bypass Valve
O-ring, 1-1/8 x 1-3/8 (2 req.)
31
32
Softener Components
J
15
16
11
\
10
9 flow plug assembly assembled
27
19
30
31
26 25
24
20
21
22
23
24
25
26
7
8
9
10
11
12
13
14
15
16
17
18
19
4
5
6
Key Part No.
No.
1
2
3
7224087
7250622
7231393
0900857
7171250
7219545
7169180
0900431
7250347
7172793
7170288
7211644
7170327
7173024
7174313
7185500
7173032
7185495
7172989
7171187
7129889
7089306
7077642
7170262
7094898
7101548
Description
Screw, #8-32 x 1" (2 req.)
Motor (incl.
2 ea. of Key No. 1)
Motor Plate
Screw, #6-20 x 3/8 (3 req.)
Bearing
Cam and Gear
Clip (Drain)
Itose Clamp
Drain Adaptor
Drain Itose Adaptor
O-ring, 15/16 x 1-3/16
How Plug, 2.0 gpm
O-ring, 5/8 x 13/16
O-ring, 1-1/8 x 1-1/2
Bearing, Wave Washer
Rotor & Disc
O-ring, 4-1/2 x 4-7/8
Rotor Seal
Seal
Plug (Drain Seal)
Spring
Clip (2 req.)
Copper Tube, 1" (2 req.)
O-ring, 1-1/8 x 1-3/8 (4 req.)
Turbine Support
Turbine
Softener Components
45
46
47
48
49
38
39
40
41
42
43
44
Key Part No.
No.
27
28
29
30
31
32
33
34
35
7248722
0900060
7081201
7195482
7171145
7170319
70811(t4
1202600
7095030
36
37
1148800
7114533
7204362
7084607
7146043
7167659
7170262
7199729
7175199
7171161
7172997
7145186
7140738
7265287
7104546
•
• 7253808
7185487
Description
Wire Ilamess (Sensor)
O-ring
Retainer (Nozzle & Vcnturi)
Seal (Nozzle & Vcnturi)
Valve Body
O-ring, 1/4 x 3/8 (2 req.)
Nozzle & Vcnturi Itousing
Nut - Ferrule
Cone Screen
Flow Plug, .3 gpm
Nozzle and Vcnturi - Gasket Kit
Gasket only
How Plug, .15 gpm
Screen
Screen Support
O-ring, 1-1/8 x 1-3/8
Cap
Wave Washer
Valve Cover
Screw, #10 x 2-5/8 (8 req.)
Switch
Screw, #4-24 x 3/4 (2 req.)
1-1/4" Installation Adaptor Kit
Plastic PVC Adaptor (2 req.) not included
Nozzle & Vcnturi Asm. (incl.
Key Nos.
33, and 35 through 42)
Seal Kit (incl.
Key Nos. 13, 14, 17, 18,
19 and 30) not illustrated
Manufactured and warranted by
Ecodyne Water Systems, Inc.
1890 Woodlane Drive
Woodbury, MN 55125
33
34
Notes
Notes
35
3/04

Download
Advertisement
Key features
- Demand-controlled operation
- Softening and regeneration cycles
- Salt efficiency feature
- Tank light
- Power-outage memory
- Water flow indicator
- Cleaning feature