Thermo Scientific TriPlus RSH Autosampler Integrated Sampling System You are productive solving your chromatography challenges A step ahead in automated sampling The quality of gas chromatography results depends on many factors – the stability of the gas chromatograph, the ruggedness and sensitivity of the detector, and the skill of the chemist in executing the proper sample workflow. Within this process, sample preparation and introduction provide the foundation for repeatability and reliability that are essential for quality data. The Thermo Scientific TriPlus RSH autosampler utilizes robotic sample handling to expand automated capabilities beyond liquid, headspace and solid-phase microextraction (SPME) injections to advanced sample handling cycles. Your results benefit from improved precision and reproducibility, while your laboratory gains unique advantages from the system’s unattended operations and sample handling flexibility. Exceptional Precision • Reproducible performance • Automate basic sample and standards preparation • Accuracy you can count on 2 Unmatched Flexibility • Scalable capabilities to expand GC and GC-MS application range Ultimate Productivity • Large sample capacities • Accurate micro-sample injections • Designed for full unattended 24/7 operation • Match techniques to sample types • Rugged tireless operations Expand productivity and sample handling with unique and powerful capabilities Experience Seamless Operation with the Innovative Automatic Syringe Exchanger In the modern laboratory, basic sample handling tasks, including standard or stock sample dilutions, internal standard addition and derivatization, require manual pipetting of precise amounts of products before any dilution or chemical reaction occurs. To accurately automate all of these steps, the TriPlus RSH™ autosampler offers a new and innovative ATC (Automatic Tool Change) capability. The ATC feature enables the user to set up a sequence using up to six different syringes, automatically loaded by the autosampler to accurately perform dilutions, calibrations, and sample injections. The ability to exchange syringes for different tasks enables high precision sample-handling in a single, unattended sequence prior to automated sample injection. TriPlus RSH automatic tool change capability 5 microliters of a liquid sample in a 300 microliter vial Developed for increased analytical flexibility and lab productivity, this unique capability automates complex sample preparation and injection workflows, thus eliminating human error. Combination of these features within one single unit, integrated on GC and GC-MS systems, saves precious lab space. Expand Unattended Operations and Productivity with Unprecedented Sample Capacity Unequivocal lab throughput is attainable by using the largest sample capacity available for an autosampler. A maximum of 972, 2 mL vials combined with multiple 100 mL wash/waste bottles, on the TriPlus RSH autosampler, enable week-end long unattended operations – a goal not attainable with most other sampling systems currently on the market. Sequences can be developed in which one autosampler serves multiple GC systems, further expanding lab productivity. This feature enables the powerful combination of screening on a single GC or GC-MS system while simultaneously performing positive confirmation/quantitation on another GC-MS or GC-MS/MS system. Further productivity is achieved by utilizing various injection modes that match techniques to sample types. Liquid, Headspace and SPME injections can all be used within a single sequence, running unattended with the use of the ATC capability, switching the syringe tool automatically as needed. Accurate micro-sample injections 1 µL splitless injection 40 ppm C20 in toluene Volume in vial (microliters) Peak area 50 81244277 40 80268993 30 82088809 20 82095395 10 84436788 5 84312030 RSD% 2.0 The TriPlus RSH autosampler provides excellent repeatability with micro-samples, down to 5 µL in a vial, particularly interesting for trace analysis, radioactive samples, or samples requiring expensive internal standards. 3 Achieve the best results for your sample type The TriPlus RSH robotic sample handling system offers liquid, headspace, and solid phase microextraction – capabilities you expect as being a standard part of a multi-axis autosampler. In these modes, the TriPlus RSH autosampler delivers the precision you demand for achieving exceptional results. Flexible Liquid Sampling and Injection Simple and Reliable Headspace Injection Solvent-free Sample Preparation with SPME The TriPlus RSH autosampler offers optimized liquid injection modes to support a wide range of sample types, inlets, and techniques for syringe filling. Parameters like pull-up strokes, viscosity delay, washing cycles, and needle depths can all be programmed, thus achieving high precision sampling. Additionally, samples can be withdrawn into the syringe using one of the following methods: Static headspace is a straight forward method for volatile analysis. Eliminating the need for a transfer line and/or sample loop, the TriPlus RSH autosampler uses a high temperature resistant gas-tight syringe for direct headspace injection. Overlapping sample incubation capability offers higher productivity. Every sample is ready for injection based on the GC cycle time. The optional Multiple Headspace Extraction (MHE) mode enables accurate quantification of volatiles in a solid or samples with interfering matrices. The TriPlus RSH autosampler automates SPME sample preparation. Optimum performance is achieved through precise control of all steps, from fiber preconditioning, to adsorption and desorption. Samples can be heated and shaken to reduce analysis times. Compounds of interest are extracted from liquid or headspace phases by simply setting the depth of needle penetration into the vials. A great productivity boost is delivered by the fiber conditioning station, which flushes and heats fibers after the injection. •R egular Mode draws the sample plug into the syringe barrel for controlled injections. •S andwich Technique utilizes an additional solvent, standard, or second sample, and provides the optimum sampling conditions even for the most critical samples. USP <467> chromatogram – Residual solvents Class II – mix A by headspace In addition to standard split/splitless injection modes, PTV and cold on-column methods are fully optimized to guarantee the highest quality results. Depending on the sample type, a new fast cold needle injection with cycle times lower than 100 ms is also available. Mixture of seven flavoring standards and two internal standards analyzed by SPME/GC-MS/MS C12 C14C16C18C20C22C24C26C28C30 C32C34C36C38C40 inj 15790321 645483965147386381364642295363416376250327590215161155685938289 58402395608114566661554897995336295 inj 25807141 647697065264546394970644086163553756251328592226561402685947775 58631265634042569096755167985358942 inj 35827629 649799765540586420246645973363791946286949595419461455555984266 59010695682593573098855507515378550 inj 45792134 644151564925786363032640478763274506252542592146960976045949291 58453515611117566433154916975332499 inj 55800582 646823065229116392049643327563608876263864595298160924595979322 58656585637562568818355201195357380 inj 65768772 646489265175036387861643294563515986268676593515561422345972692 58630805635080568777055178325353762 inj 75823193 647618765310496398825644194163672046265981594927961458215989443 58983545662424571753055386845370648 inj 85790579 644070964893386363591640351163285966240425592866060954605966984 58715355627761567937055030105335919 inj 95802600 645824265125546377256642341763493686249385594160360901665964591 58717285643593569609455175805350256 inj 10 5862631 646969265208456388855643588263669096264664594700461414755998001 59003935657099570914155273815358868 mean 5806558 646492765182036386805642993163528226259414593547661206615969065 58720535639939569309955173655353312 sd 25973 172571850516955170911680413295168182461619487 2176522825212741915615098 RSD% 0.4 0.30.30.30.30.30.20.30.40.3 0.40.40.40.30.3 Peak area repeatability of a splitless injection of a “Florida Mix” standard 4 Increased automation and error-free sample handling Move beyond automated sample injections to more advanced tasks, such as sample preparation, dilutions, standard curve generation, and derivatization routines by taking advantage of the newest technology in sample handling systems. Sequential Dilution A high concentration standard is automatically diluted to easily meet your requirements. Sequential dilution Calibration Dilution Reliability and precision for your quantitative calibration. Prepare your calibration points with or without internal standards. Standard Addition Add precise amounts of standards to any vial. Calibrating by standard addition is commonly used in headspace and SPME analyses. The accurate addition of standards is now a reliable, automated step in the measurement cycle. Derivatization Precise volumes, internal standard and reagent additions, with programmed incubation times – an all in one automated procedure that occurs just prior to injection. Mixing Vials undergo automatic agitation after the addition of standard volumes. You can also speed-up headspace and SPME applications to reach the equilibrium faster. Calibration dilution with internal standard Unknown biodiesel analysis with automated derivatization and internal standard addition Incubator for mixing and derivatization Vortexing Physical vortexing for thorough mixing can be used for liquids homogenization and extraction steps with solvents. Vortexer utilizing different vial sizes 5 Powerful options to expand applications, preserve sample integrity and enable sample traceability Expand Applicability to Include Unstable Compounds or Viscous Samples HT SimDist – Heavy fraction crude oil sample analysis and POLYWAX® 1000 standard. Automated On-Column injection systems Temperature-controlled tray options protecting sensitive samples can be incorporated into the TriPlus RSH autosampler quickly at any time. An affordable solution for large 10/20 mL vials can control temperatures from 4 °C up to 70 °C with an external thermostatic bath. Alternatively, a temperature-controlled option can accommodate a wide range of vial types, providing stable temperature control for accurate sampling of very volatile solvents, unstable compounds, or extremely viscous samples. Enhanced Sensitivity for Headspace Analysis Sample enrichment is a valuable tool for the analysis of trace levels of volatile organics in difficult matrices with the use of headspace injections. Combining the TriPlus RSH autosampler capability of handling multiple sequential headspace injections with a cryogenic GC option, sensitivity is greatly enhanced as a larger sample volume can be efficiently analyzed. This capability is ideal for the simplification of demanding environmental analyses. Four sample enrichment MS Quadrupole (Full scan Extracted ions) 5 mL of 500 ppt water solution of Halogenated Volatiles Mix 551A Utilize Barcode Reading for Enhanced Sample Traceability The convenient dual-laser barcode reader is capable of reading vertical 1-D barcode labels on 2,10 and 20 mL vials. The dual-scanner capability allows the TriPlus RSH autosampler to read vial barcodes, regardless of their position in the vial, making it easier to build sequences and ensure complete sample traceability. 6 A fully validated laboratory solution making you productive from day one Validated Consumables for Trusted Results A complete selection of Thermo Scientific consumables complements our innovative range of GC and GC-MS systems. They include micro vials, vials for liquid and headspace, magnetic and plastic caps, snap-on, screw- and crimp-top caps, a wide choice of liquid and gas-tight syringes, well plates, trays and much more. All types of syringes, vials, and caps offered to accommodate the largest choice of application requirements All of these consumables are designed and tested to work problem-free with the TriPlus RSH autosampler. Integrated Software Control for Quick Setup and Intuitive Sample Workflow The TriPlus RSH instrument control – from installation and setup to the most complex sequence – is fully embedded on standard Thermo Scientific Chromatography Data Systems including Chromeleon 7.1. GC-MS operations run smoothly with integrated TriPlus RSH autosampler controls on Thermo Scientific Xcalibur and TraceFinder software. Three basic setup screens (available on all Thermo Scientific software platforms), easily guide the setting of TriPlus RSH parameters for Liquid, Headspace and SPME methods. Despite the large number of configurations and options offered within the basic injection modes, instrument setup and methods are created quickly with just a few mouse clicks. Sample preparation cycles are available as add-ons through pre-compiled sequences with application descriptions. Graphic-assisted flexible instrument programmability for easy start-up and workflow operations. Methods and sequences can be developed and run locally or remotely through the use of a convenient network card. A virtual terminal, fully integrated within the same software control, completely mimics the physical handheld controller and enables easier installation and initial setup. Convenient Handheld Option for Local Control The handheld controller is the ideal solution for displaying instrument status and facilitating setup and maintenance. Laboratories equipped with multiple TriPlus RSH autosamplers will also benefit from the operational flexibility provided by this controlling tool, using a single handheld device to set up all TriPlus RSH autosamplers in the lab. 7 Thermo Scientific solutions for your gas chromatography needs TRACE 1300 GC The Thermo Scientific TRACE 1300 GC is the ideal budget-conscious investment for the basic routine laboratory when lower operator expertise requires ease of use with minimal instrument interaction. TRACE 1310 GC Ideal for larger routine QA/QC laboratories, the TRACE™ 1310 GC offers a complete icon-based touch screen interface, which is ideal for direct instrument control when method development is required. While retaining all of the capabilities and performance of the TRACE 1300 GC model, it also provides local status update of the oven, injectors and detectors, maintenance commands, run log, multiple language capabilities and video tutorials to drive simple instrument interaction. ISQ Single Quadrupole GC-MS The Thermo Scientific ISQ GC-MS system offers rugged and reliable performance and nonstop productivity. The ISQ™ GC-MS features a new source design ideal for continuous high-throughput operation. The vacuum interlock enables source removal without venting the system, for unstoppable productivity. ITQ Series GC-Ion Trap MS TheThermo Scientific ITQ Series GC-Ion Trap MS offers outstanding full-scan electron ionization sensitivity and upgradeability. From a small-footprint entry-level QA/QC instrument to a fully-featured, research-grade system with advanced MSn functionality, the ITQ™ Series GC-MS system offers a broad range of standard features along with an impressive list of options. TSQ 8000 Triple Quadrupole GC-MS/MS The Thermo Scientific TSQ 8000 system is reliable, easy to use and enables faster, more precise analyses with unstoppable productivity. Designed for routine analysis, the TSQ™ 8000 system integrates proven triple quadrupole technology with a rich software suite for uncompromised MS/MS simplicity from startup to final report. TSQ Quantum XLS Series Triple Quadrupole GC-MS/MS The Thermo Scientific TSQ Quantum XLS Ultra is the new “Gold Standard” in GC-MS/MS. Thermo Scientific HyperQuad technology delivers highly increased mass resolving quadrupoles for ultra-selective SRM, with best-in-class sensitivity, and allows unsurpassed analytical performance for the most difficult matrix challenges. www.thermoscientific.com ©2011–2012 Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. Solid Phase Microextraction (SPME) Technology is licensed exclusively to Supelco Inc. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Africa-Other +27 11 570 1840 Australia +61 3 9757 4300 Austria +43 1 333 50 34 0 Belgium +32 53 73 42 41 Canada +1 800 530 8447 China +86 10 8419 3588 Denmark +45 70 23 62 60 Europe-Other +43 1 333 50 34 0 Finland/Norway/Sweden +46 8 556 468 00 France +33 1 60 92 48 00 Germany +49 6103 408 1014 India +91 22 6742 9434 Italy +39 02 950 591 Thermo Fisher Scientific S.p.A. Milan, Italy is ISO Certified. Japan +81 45 453 9100 Latin America +1 561 688 8700 Middle East +43 1 333 50 34 0 Netherlands +31 76 579 55 55 New Zealand +64 9 980 6700 Russia/CIS +43 1 333 50 34 0 South Africa +27 11 570 1840 Spain +34 914 845 965 Switzerland +41 61 716 77 00 UK +44 1442 233555 USA +1 800 532 4752 BR52235_E 09/12M
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement