Cres Cor H137WSUA 12D, 5D, 6D, 12D208, 5D208, 6D208, 12D240, 5D240, 6D240, H138WS18 5D, 34D, 16D, 5D208, 34D208, 16D208, 5D240, 34D240, 16D240 Hot Cabinet Operating and Maintenance Instructions

Cres Cor H137WSUA 12D, 5D, 6D, 12D208, 5D208, 6D208, 12D240, 5D240, 6D240, H138WS18 5D, 34D, 16D, 5D208, 34D208, 16D208, 5D240, 34D240, 16D240 Hot Cabinet Operating and Maintenance Instructions

The Cres Cor 1000-CH-AL Heated Holding Cabinet offers various features to keep food warm and ready to serve. Equipped with a digital control panel, it allows precise temperature adjustment and displays the current temperature inside the cabinet. The unit's insulated walls and doors help retain heat efficiently, reducing energy consumption. Its stainless steel construction ensures durability and easy cleaning. The cabinet's adjustable shelves accommodate different size pans and containers, providing flexible storage options.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Hot Cabinet H137WSUA 12D Operating and Maintenance Instructions | Manualzz

Insulated

Hot Cabinets

Rev. 0 (7/11)

5925 Heisley Road • Mentor, OH 44060-1833

OPERATING and MAINTENANCE INSTRUCTIONS

Models: H137WSUA...D & H137WS18...D Series

Humidity Holding Hot Cabinet

ELECTRICAL SPECIFICATIONS:

Model No.

Volts

H137WSUA12D

H137WSUA5D

H137WSUA6D

H138WS185D

H138WS1834D

H138WS1816D

120

Watts

2000

Amps

16.7

Hertz

60

Phase NEMA

1 5-20P

FL-2355

Page 1 of 6

H137WSUA12D208

H137WSUA5D208

H137WSUA6D208

H138WS185D208

H138WS1834D208

H138WS1816D208

208 2000 9.6

60

H137WSUA12D240

H137WSUA5D240

H137WSUA6D240

H138WS185D240

H138WS1834D240

H138WS1816D240

240 2000 8.3

60

NOTE: The above model numbers are basic models.

They may be followed by letters: M, L, E or ending with S, Z U, and/or HT.

1

1

6-15P

6-15P

HOW TO INSTALL UNIT:

1. Place cabinet on level floor, in a well ventilated area.

2. Unpack and install inner pan slides parts.

3. Plug cord end into proper wall outlet.

FIRST TIME OPERATION:

NOTE: A new oven needs to “burn off” manufacturing oils and excess adhesive before its first use.

Do NOT load food into oven until this has been done!

1. Push the switch on; the light will come on.

NOTE: The letters “LOTPR” (Low Temperature) will show on the control panel until it reaches 140°F (60°C).

WARNING

Air is VERY HOT when door is opened.

2. Turn the control knob to show 220°F. Push the knob to set the temperature. Run the unit for one

(1) hour.

3. Push the switch off the unit off and let cool.

4. Wipe the inside clean with detergent and hot water.

Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

Insulated

Hot Cabinets

Rev. 0 (7/11)

FL-2355

Page 2 of 6

5925 Heisley Road • Mentor, OH 44060-1833

OPERATING and MAINTENANCE INSTRUCTIONS

Models: H137WSUA...D & H137WS18...D Series

Humidity Holding Hot Cabinet

"ON-OFF" SWITCH

"HOT HOLDING"

DIGITAL CONTROL

"AQUATEMP"

DIGITAL CONTROL

ACTUAL CABINET

TEMPERATURE

ON-OFF

LOW WATER LIGHT

HUMIDITY READING

HOW TO HOLD:

No water is needed in pan.

1. Push the switch on; the light will come on.

DIGITAL CONTROL NOTES

*Press the “display” button to see the actual temperature inside the cabinet (press again to shut off).

NOTE: The letters “LOTPR” will show on the control panel until it reaches 140°F (60°C).

*Press the “display actual” button to see the approximate relative humidity (press again to shut off).

2. Turn the “Hot Holding” control knob to a temperature between 140°F (60°C) to 220°F (104°C).

Push the knob to set the temperature.

3. Preheat the cabinet for 30 minutes.

temperature inside the cabinet.

HOW TO HOLD WITH HUMIDITY:

Fill water pan with 4 gallons (15 liters) of HOT water.

*Small letters in upper right corners of the displays are:

Hot Holding control: “S” = setpoint temperature

“A” = actual temperature

X:\ENGINEER\FLSHEETS\FL2355 CONTROL PANEL

(in increments of 5)

“A” = approximate relative humidity reading

1. Push the switch on; the light will come on.

NOTE: When the low water light is on, the “A” numbers will not be close to an accurate reading.

NOTE: The letters “LOTPR” will show on the control panel until it reaches 140°F (60°C).

2. Turn the “Hot Holding” control knob to show 140°F.

(60°C.). Push the knob to set the temperature.

3. Turn the “AquaTemp” knob to “95” setting. Push the knob to set the temperature.

4. Preheat the cabinet for 1/2 hour (30 minutes).

NOTE: These settings are based on laboratory conditions and may differ from conditions at the point of use. Experiment with the settings to determine what is best for your application.

HOW TO TURN UNIT OFF:

Push switch off; light will go out.

Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

Insulated

Hot Cabinets

Rev. 0 (7/11)

FL-2355

Page 3 of 6

5925 Heisley Road • Mentor, OH 44060-1833

OPERATING and MAINTENANCE INSTRUCTIONS

Models: H137WSUA...D & H137WS18...D Series

Humidity Holding Hot Cabinet

DAILY MAINTENANCE:

WATER PAN

Drain, wipe and fill water pan daily. (Clear vinyl drain hose is provided.)

1. Push hose onto drain nozzle under the cabinet base.

2. Turn knob to open the drain.

CABINET

1. Wipe the inside of the cabinet after daily use.

2. LEAVE DOORS SLIGHTLY OPEN TO FULLY

DRY INTERIOR.

Delime or descale water pan parts as required, to prevent damaging buildup. WARRANTY COVERAGE MAY

BE AFFECTED WITHOUT PROPER

CLEANING.

WARNING

BEFORE CLEANING CABINET:

1. Allow cabinet to cool.

2. Do NOT hose cabinet with water.

3. Do NOT get water on controls.

4. Do NOT use abrasives or harsh chemicals.

Cleaning hints:

1. Wipe up spills as soon as possible.

2. Clean cabinet regularly to avoid heavy dirt build-up.

3. Make a test spot with cleaner.

4. Follow manufacturer’s directions on cleaner.

5. Do not mix cleaners.

6. Avoid drips and splashes.

7. Do not use “Cres Clean” on plastic parts or labels.

HOW TO CLEAN THE UNIT:

CABINET

Inside and

Outside

(Stainless Steel)

Soil

ROUTINE CLEANING

STUBBORN SPOTS AND

STAINS

BURNT-ON FOODS OR

GREASE

Cleaner

Soap, Ammonia, or mild

*detergent and water.

Mild abrasive made for stainless steel.

Chemical oven cleaner for stainless steel.

Method

1. Sponge on with cloth.

2. Rinse with water.

3. Wipe dry.

1. Apply with damp sponge or cloth.

2. Rub lightly.

Follow oven cleaner manufacturer’s directions.

HARD WATER SPOTS and SCALE

Vinegar

1. Swab or wipe with cloth.

2. Rinse and dry.

*Mild detergents include soaps and non-abrasive cleaners.

NOTE: Gaskets are removable for cleaning.

Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

Insulated

Hot Cabinets

Rev. 0 (7/11)

FL-2355

Page 4 of 6

5925 Heisley Road • Mentor, OH 44060-1833

OPERATING and MAINTENANCE INSTRUCTIONS

Models: H137WSUA...D & H137WS18...D Series

Humidity Holding Hot Cabinet

WARNING

RISK OF FIRE OR ELECTRIC SHOCK

DO NOT OPEN

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK)

NO USER-SERVICEABLE PARTS INSIDE

REPAIR SHOULD BE DONE BY AUTHORIZED SERVICE

PERSONNEL ONLY

TROUBLE-SHOOTING CHART:

FAILURE:

1. Switch light or control display does NOT light up.

2. Unit gets too hot or won’t shut off.

3. Unit does not heat.

4. No humidity

POSSIBLE CAUSE:

1a. Circuit breaker/fuse to wall outlet is blown

1b. Cord is unplugged from wall outlet.

1c. Switch is “OFF.”

1d. Switch or control defective.

2a. Relay or control defective.

UNPLUG UNIT FROM WALL OUTLET

3. Defective heater, relay, blower or control.

4a. Low water

4b. Air temperature set too high.

4c, Defective heater, relay or control.

Controller (Thermostats) Error codes: err 00 - Temperature probe defective err 01 - Water fill time out

Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

Insulated

Hot Cabinets

Rev. 0 (7/11)

FL-2355

Page 5 of 6

5925 Heisley Road • Mentor, OH 44060-1833

OPERATING and MAINTENANCE INSTRUCTIONS

Models: H137WSUA...D & H137WS18...D Series

Humidity Holding Hot Cabinet

REPLACEMENT PARTS:

Blower Kit

Heater Kit, Air

Heater Kit, Water

High Limit (water pan)

High Limit - 400°F

Power Cord

Relay, Solid State

Switch, Power

Thermostat Control (Hot)

Thermostat Control (Humidity)

Thermostat Probe

Terminal Block

Transformer

Vent Fan

2000W

1000W

1850W

2000W

1000W

120V

0769-180-K

0811-022

0811-297

0811-271

0848-060

0848-033

0810-065-12

0810-029-06

0857-136

0808-125

0848-092-01-K

0848-092-02-K

0848-091-K

0852-119

0769-197

0769-165

208V

0769-182-K

0811-185

0811-298

0811-271

0848-060

0848-033

0810-039-07

0810-039-07

0857-136

0808-125

0848-092-01-K

0848-092-02-K

0848-091-K

0852-119

0769-197

0769-174

240V

0769-182-K

0811-023

0811-299

0811-271

0848-060

0848-033

0810-039-07

0810-039-07

0857-136

0808-125

0848-092-01-K

0848-092-02-K

0848-091-K

0852-119

0769-197

0769-174

Door, Complete

(Stainless Steel)

Door, Gasket

(Stainless Steel)

Door Hinge

Door Latch

Door Handle

Handle, Side Pull

Casters, 5”

Casters, 5” w/brake

UA12/UA6/1834/1816

UA5

UA12/UA6/1834/1816

UA5

1221-579

1221-

0861-185

0861-250

0519-074-K

1006-122-01-K

0911-111

0911-087

0569-306

0569-306-B

Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

Insulated

Hot Cabinets

Rev. 0 (7/11)

FL-2355

Page 6 of 6

5925 Heisley Road • Mentor, OH 44060-1833

OPERATING and MAINTENANCE INSTRUCTIONS

Models: H137WSUA...D & H137WS18...D Series

Humidity Holding Hot Cabinet

WIRING DIAGRAM: 120V

WIRES 1 AND 2. REPLA WITH WIRES 41, 42, 43, 44 AND WIRE AS SHOWN: POWER SWIT

VENT FA VENT FA

AIR PR

L1 T1

A2(-)

A1(+)

UPPER FL

LOWER FL

L1 T1

A2(-)

A1(+)

DOWN OPPOSITE SIDE FR

Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

advertisement

Key Features

  • Digital temperature control
  • Humidity control system
  • Stainless steel construction
  • Easy to clean
  • Durable and reliable

Frequently Answers and Questions

How do I set the temperature on the hot cabinet?
To set the temperature, turn the "Hot Holding" control knob to the desired temperature and push the knob to set it. The control panel will display the setpoint temperature. You can also monitor the actual temperature inside the cabinet by pressing the "display actual" button.
How do I clean the hot cabinet?
To clean the hot cabinet, allow it to cool completely. Wipe the inside of the cabinet with a mild detergent and hot water. You can also use a chemical oven cleaner for stainless steel to remove burnt-on foods or grease. Make sure to follow the manufacturer's directions on the cleaner and avoid getting water on the controls.
What are the different model numbers?
The basic model numbers are followed by letters: M, L, E or ending with S, Z U, and/or HT. The model numbers may vary depending on the specific features and options.

Related manuals

Download PDF

advertisement