Rotel RC-1580 RS232 HEX Protocol

Rotel RC-1580 RS232 HEX Protocol
Rotel RC-1580
RS232 HEX Protocol
Date
February 2, 2012
Version
1.00
Update Description
Original Specification
The RS232 protocol structure for the RC-1580 is detailed below. This is a HEX
based communication protocol.
Connection Settings
Baud Rate
19200
Parity
N
Valid Data Bits
8
Stop Bit Value
1
Handshaking
None
Data Type
String
All commands sent to the attached Rotel device must follow the command structure
detailed below, unless specified otherwise. Send only the bytes only, no spaces,
delimeter, etc.
Standard Command String Format
Start
0xFE
Count
0x03
Device ID
0x08
Type
0x10
Key
0xXX
Checksum
0xXX
Note: The count byte only includes the ID, Type, and Key bytes; it does not include the
Start or Checksum bytes.
Note 2: Do not include any carriage returns or line feeds after the commands
Communication Protocol
Command and response messages are included on the following pages. The
standard response string of the unit mirrors the data that would be available on the front
panel of the unit.
Any change to the status of the front display on the unit will prompt a feedback string
mirroring that change.
Note that the spaces shown between hex bytes below are for clarity only; do not include
spaces in the actual command sent to the unit.
Meta Encoding
The start byte for all command and response strings is FE. To keep the device
from encountering the start byte FE in any position other than as the start byte, any
occurrence of the byes FD or FE in a command string must be converted to either FD 00
(for FD), or FD 01 (for FE). This will allow the string to pass while masking any
occurrence of the byte FE except as the start byte. Commands that have Meta Encoding
applied will be highlighted in red.
1
Section 1: Control Command List
RC-1580 HEX
Command Description
POWER & VOLUME COMMANDS
FE 03 08 10 00 0B
Power Toggle
FE 03 08 10 01 1C
Power Off
FE 03 08 10 02 1D
Power On
FE 03 08 10 13 2E
Volume Up
FE 03 08 10 14 2F
Volume Down
FE 03 08 10 15 30
Mute Toggle
SOURCE SELECTION COMMANDS
FE 03 08 10 03 1E
Source Phono
FE 03 08 10 04 1F
Source CD
FE 03 08 10 05 20
Source Tuner
FE 03 08 10 06 21
Source Aux 1
FE 03 08 10 07 22
Source Aux 2
FE 03 08 10 08 23
Source Aux 3
FE 03 08 10 09 24
Source Tape 1
FE 03 08 10 0A 25
Source Tape 2
RECORD SOURCE SELECTION COMMANDS
FE 03 08 10 0B 26
Record Source Phono
FE 03 08 10 0C 27
Record Source CD
FE 03 08 10 0D 28
Record Source Tuner
FE 03 08 10 0E 29
Record Source Aux 1
FE 03 08 10 0F 2A
Record Source Aux 2
FE 03 08 10 10 2B
Record Source Aux 3
FE 03 08 10 11 2C
Record Source Tape 1
FE 03 08 10 12 2D
Record Source Off
FE 03 08 10 1A 35
Record Function Select
THEATER BYPASS COMMANDS
FE 03 08 10 1B 36
Theater Bypass Toggle
FE 03 08 10 1C 37
Theater Bypass On
FE 03 08 10 1D 38
Theater Bypass Off
Section 2: Feedback String Format
Standard Response String Format
Start
0xFE
Count
0x2C
Device ID
0x08
Type
0x20
Data0 - Data41 (42 Bytes)
ASCII Characters
Checksum
0xXX
The ASCII data will contain the source and record source name information and should
be parsed to obtain unit status. Current volume is not available as this unit uses a rotary
knob for volume not numerical values.