INSTALLATION AND
MAINTENANCE GUIDE
Static Pressure Head
SPH10
– Eliminates effectively wind disturbances from pressure measurements
to many barometers, directly to Vaisala PTB210
– Durable and easy to clean
© Vaisala 2012. All rights reserved.
*M211542EN*
INTRODUCTION
Vaisala model SPH10 Pressure Head provides an effective elimination of pressure variations in the barometer due to the wind. The SPH10 is easy to clean and maintain. It can be integrated directly with the Vaisala PTB210 barometer. To other barometers the SPH10 can be connected with pressure tubing.
ASSEMBLING
1. Screw the lower bar to the threaded sleeve of the lower plates (with 6 holes).
2. Screw the upper bar (with mounting plate) to the threaded sleeve of the upper plates.
MOUNTING
Select an open location, prefereably a place higher than the surroundings, with no buildings or trees nearby. Attach the
SPH10 to a horizontal pole using a mounting plate. A suitable pole is Vaisala sensor mast, type DKP12. However, any other horizontal pole with two screws (M6) in a distance of 41 mm can be used.
NOTE The recommended distance of the SPH10 from the vertical pole is at least 1.5 m.
1. Loosen the two fixing screws of the pole and fix the SPH10
into the pole as indicated in Figure 1.
2. Attach the SPH10 by tightening the screws. (The pressure
Head is removed by loosening the two screws).
CONNECTION TO THE VAISALA PTB210
1. Detach the threaded nipple and the gasket (see figure 1).
2. Place the O-ring into the barometer groove.
3. Attach the PTB210 to the SPH10 with two fixing screws.
CONNECTION TO OTHER BAROMETERS
Connect the barometer to the threaded nipple (Figure 1) by using
a flexible, airtight tube with an inner diameter of 4 mm. To prevent condence water accumulation in the tube, make sure the entire length of the tube goes downwards from the barometer to
SPH10.
Figure 1 SPH10 Static Pressure Head
Figure 2 PTB210 Barometer Connection
For warranty information, visit our Internet pages at: www.vaisala.com/warranty.html
TECHNICAL DATA
Materials
Plates
Bars
Mounting
Weight
Hose connection
Polycarbonate
Offshore Aluminium with 2 bolts
(M6 x minimum 20 mm)
800 g barbed fitting for 4 mm I.D. hose or Rp1/4 thread
(parallel)
WARRANTY
Visit our Internet pages for standard warranty terms and conditions: www.vaisala.com/warranty .
Please observe that any such warranty may not be valid in case of damage due to normal wear and tear, exceptional operating conditions, negligent handling or installation, or unauthorized modifications. Please see the applicable supply contract or
Conditions of Sale for details of the warranty for each product.
TECHNICAL SUPPORT AND PRODUCT
RETURNS
For technical questions, contact the Vaisala technical support by e-mail at [email protected]
.
If the product must be returned for service, see www.vaisala.com/returns .
For contact information of Vaisala Service Centers, see www.vaisala.com/servicecenters .
MAINTENANCE
Figure 3 Detaching the Lower Plate for Cleaning
Cleaning the SPH10 is done by detaching the lower bar and the lower plate. The barometer can be in place while cleaning the plates. Follow the instructions below:
1. Unscrew the lower bar and detach it.
2. Open the self-locking nut with a 13 mm spanner.
3. Remove the threaded sleeve and take out the lower plate and the protective wire net.
4. Clean the plates.
5. Replace the lower plate, the protective wire net and the threaded sleeve, screw back the nut and the lower bar.
Keep the holes of the lower plate open to allow the water run out.
DIMENSIONS
All dimensions in mm.
Visit our Internet pages at www.vaisala.com