Kübler Draw wire encoder Mounting Instruction

Below you will find brief information for Draw wire encoder. The Draw wire encoder is a high quality measuring device and should be mounted to a flat surface. The unit should be used only according to the protection level provided. Protect the encoder if necessary, against environmental influences such as sprayed water, dust, knocks, extreme temperatures.

PDF Download
Document
Draw wire encoder Mounting Instruction | Manualzz

Advertisement

Advertisement

Advertisement

Key features

  • High quality measuring device
  • Can be mounted to a flat surface
  • Protection against environmental influences
  • Can be used with an extension wire
  • Can be used with guide rollers
  • Can be fitted to an incremental or absolute encoder
  • Adjustment of the reference point
  • Maximum extension length must not be exceeded
  • Wire must be extended co-axially to the wire outlet
  • Wire should always be under tension

Frequently asked questions

The encoder's breakaway torque and operational torque must not exceed the admissible value of 3 Ncm.

For adjusting the reference point loosen the screws until the encoder can be turned. Rotate the encoder in arrow direction until the reference point is reached; then re-tighten the screws.

The maximum extension length of the wire must not exceed the overall length of the measuring range + lead length.

The wire must be extended co-axially to the wire outlet to avoid damage to the wire outlet and to ensure the unit’s maximum life.