BOCK OIL-FIRED WATER HEATERS 7
BOCK OIL-FIRED WATER HEATERS
Bock
Oil-Fired Residential Water Heaters
7
NOTE: Purchase burners separately. See below.
Size
BTUH
Firing
Rate
Recovery
90° F
Rise
Delivery
@ 1st Hr.
90° F Rise
Dimensions
H x Dia.
Cold Inlet x
Hot Outlet
HVAC EQUIPMENT
FEATURES:
• Turboflue® heat exchanger – patented multi-finned heat exchanger minimizes
waste heat, transferring it to water for greater efficiency and high energy savings.
• C-glass porcelain enamel lining that exceed industry standards by 53%.
• Two large magnesium anode rods maximize the life of the tank by inhibiting
corrosion. They are easily replaced from the top.
• Center flue – heavy gauge steel traps heat inside. The flue is completely
surrounded by water.
• Refractory combustion chamber adds durability and provides excellent
heat retention.
• T&P safety valve.
• Accessible drain simplifies regular inspection of water condition.
Large enough to flush away lime and sediment deposits.
• UL listed.
• Warranty: 5 year limited warranty.
Wt.
Item#
Price
WATER HEATER ONLY – BURNERS SOLD SEPARATELY
32 gal. 104,000
0.75 gph
112 gph
138 gph
43-1/4" x 24"
3/4" x 3/4"
280 lb.
33E
32 gal.
104,000
0.75 gph
112 gph
138 gph
51" x 20"
3/4" x 3/4"
279 lb.
32E
1,253.14
50 gal.
152,000
1.1 gph
166 gph
206 gph
59" x 24"
1" x 1"
364 lb.
51E
1,672.16
70 gal.
173,000
1.25 gph
185 gph
421 gph
66" x 26"
1" x 1-1/2"
494 lb.
71E
2,358.20
$1,411.18
COMPATIBLE OIL BURNERS FOR USE WITH BOCK OIL-FIRED WATER HEATER MODELS
Bock Model#
Beckett Burner
33E
B5001
$658.76
Price
96828
Carlin Burner
$636.10
Price
371-001
Wayne Burner
$649.18
Price
32E
B5001
658.76
96828
636.10
371-001
649.18
51E
B5003
640.14
96828
636.10
371-003
649.18
71E
B5005
631.50
96828
636.10
371-017
649.18
Tank Flushing Procedure
1. Shut off electrical power to the heater and disconnect the cold water supply.
2. Completely drain the heater and remove the drain valve.
3. Install a 3/4” x 6” nipple with a garden hose adapter into the drain valve spud (opening) and run it to
the floor drain, a bucket, or another method of removing water from the work area.
4. Use a straight adjustable spray nozzle (set for a wide angle) attached to a garden hose. Insert the
nozzle into the cold water inlet spud and wash down the interior sides of the tank. this will remove any
particles that have adhered to the sides of the tank. Slowly begin to lower the nozzle into the tank
until it reaches the bottom. Repeat this process several times to be sure the interior walls are clean.
5. Close the drain valve, refill the heater and return it to service.
SOURCE: BOCK WATER HEATERS, INC.