Viking 100 VGBQ1302, 100 VGBQ1363, 300 VGBQ3302RE, 300 VGBQ3363RE, 500 VGBQ53002RE, 500 VGBQ54203RE, 500 VGIQ54203RE, 500 VGBQ55404RE, 500 VGIQ55404RE Outdoor Gas Grill Installation guide

Viking 100 VGBQ1302, 100 VGBQ1363, 300 VGBQ3302RE, 300 VGBQ3363RE, 500 VGBQ53002RE, 500 VGBQ54203RE, 500 VGIQ54203RE, 500 VGBQ55404RE, 500 VGIQ55404RE Outdoor Gas Grill Installation guide
Add to My manuals

Below you will find brief information for 500 VGBQ53002RE, 500 VGBQ54203RE, 500 VGIQ54203RE, 500 VGBQ55404RE, 500 VGIQ55404RE. This guide describes a comprehensive installation process for the Viking outdoor gas grills. It covers important safety instructions, clearance dimensions, cutout dimensions, gas and electrical connection requirements, LP/propane tank requirements and connection, leak testing, burner adjustment, and rotisserie system. It also provides a performance checklist and information about servicing the grill.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Viking Outdoor Gas Grill Installation Guide | Manualzz

Viking Installation Guide

Viking Range Corporation

111 Front Street

Greenwood, Mississippi 38930 USA

(662) 455-1200

For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.com

F20896A EN (011012)

Outdoor Gas Grills

Table of Contents

Important Safety Instructions __________________________________________________________2

Dimensions (30" & 36" 100 and 300 Series)_____________________________________________4

Specifications (30" & 36" 100 and 300 Series)___________________________________________5

Dimensions (30" & 42" 500 Series Grills) _______________________________________________6

Specifications (30" & 42" 500 Series Grills) _____________________________________________7

Dimensions (54" 500 Series Grill) ______________________________________________________8

Specifications (54" 500 Series Grill) ____________________________________________________9

General Information ________________________________________________________________10

Clearance Dimensions (100 and 300 Series)____________________________________________12

Clearance Dimensions (500 Series)____________________________________________________14

Cutout Dimensions (100 and 300 Series) ______________________________________________17

Cutout Dimensions (500 Series) ______________________________________________________19

Ventilation for Built-In Installations When Using an Enclosed LP-Gas Cylinder ______________22

Gas and Electrical Connection _______________________________________________________23

Natural Fixed Piping Connection _____________________________________________________24

LP/Propane Fixed Piping Connection _________________________________________________25

Built-In Installations _____________________________________________________________26

LP/Propane Tank Requirements ______________________________________________________26

LP/Propane Tank Connection ________________________________________________________27

Leak Testing _______________________________________________________________________28

Burner Adjustment__________________________________________________________________30

Rotisserie System ___________________________________________________________________32

Final Preparation ___________________________________________________________________33

Performance Checklist ______________________________________________________________33

Service & Registration _______________________________________________________________34

IMPORTANT–

Please Read and Follow

• Before beginning, please read these instructions completely and carefully.

• Do not remove permanently affixed labels, warnings, or plates from product. This may void the warranty.

• Please observe all local and national codes and ordinances.

• The installer should leave these instructions with the consumer who should retain for local inspector’s use and for future reference.

• This outdoor cooking appliance shall be only used outdoors and shall not be used in a building, garage or any other enclosed area.

Installation must conform with local codes or in the absence of codes, the National Fuel Gas

Code, ANSI Z223.1/NFPA 54.

In Canada: Installation must be in accordance with the current CSA-B149.1, Natural Gas and Propane

Installation Code or CSA-B149.2, Propane Storage and Handling Code and/or local codes. For units with an external electrical source, when installed, must be electrically grounded in accordance with local codes or with the National Electrical code

ANSI/NFPA 70, or Canadian Electrical code, CSA

C22.1.

WARNING

DANGER

IMPORTANT –

Please Read and Follow

WARNING

This outdoor gas grill is not intended to be installed inside a home or on recreational vehicles and/or boats.

WARNING

This appliance is not fused. Installer must install a ground fault interrupt.

WARNING

ELECTRICAL SHOCK HAZARD

This appliance is equipped with a 3’ (91.4 cm)

3-prong power cord with a grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle. Do not cut or remove the grounding prong from this plug. This unit is not fused and installer must install a GFI. Unit must be grounded in accordance with local codes or with the National Electrical Code ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

DANGER

WHAT TO DO IF YOU SMELL GAS:

• Shut off gas to the appliance.

• Extinguish any open flame.

• Open lid.

• If odor continues, keep away from the appliance, immediately call your gas supplier or your fire ddeeppaarrttm ntt..

WARNING

EXCESSIVE WEIGHT HAZARD

Use two or more people to move and install this unit. Failure to follow this instruction can result in back or other injury.

WARNING

Keep electrical supply cord and the fuel supply

CAUTION

FOR YOUR SAFETY

If not installed, operated and maintained in accordance with the manufacturer’s instructions, this product could expose you to substances in fuel or fuel combustion which can cause death or serious illness and which are known to cause cancer, birth defects or other reproductive harm.

For example, benzene is a chemical which is part of the gas supplied to the cooking product.

It is consu-incomplete combustion. Properly adjusted burners with a bluish rather than yellow flame minimize incomplete combustion.

FOR YOUR SAFETY

• DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

• Any LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.

CAUTION

Conversions should only be performed by an authorized service technician.

CAUTION

Before placing into operation, always check for gas leaks with a soapy water solution. DO NOT

USE AN OPEN FLAME TO CHECK FOR LEAKS.

3

Dimensions

(30" & 36" 100 and 300 Series)

17"

cm

)

30" 100 and 300 Series Grill

27-3

/4"

)

10-5

/8"

)

30"

cm

)

29

"

(73

.6 c m)

10-5

/8”

)

17"

cm

)

36" 100 and 300 Series Grill

34-1

/4"

)

35-7

/8"

)

29

"

(73

.6 c m)

*Rotisserie available in 300 Series Models Only

4

Specifications

(30" & 36" 100 and 300 Series)

Description

Cutout width

Cutout depth

Cutout height

Overall width

Overall depth

Gas requirements

Electrical requirements

30”W. & 36”W. 100 and 300 Series Grills

VGBQ1302/VGBQ3302RE

29-1/4”

(74.2 cm)

VGBQ1363/VGBQ3363RE

24 3/8" (67.9 cm)

10 1/8" (25.7 cm)

35-1/4”

(89.5 cm)

30”

(76.2 cm)

35-7/8”

(91.1 cm)

29” (73.6 cm)

Natural: standard residential 1/2” (1.3 cm) ID gas service line.

LP/Propane: Equipped with high capacity hose/regulator assembly for connection to standard 5gal, 20 lb. LP/Propane gas cylinder with Type 1, QCC-1 connection or standard residential 1/2”

(1.3 cm) ID gas service line.

100 Series Models:

9 volt DC battery for electronic ignition

Grill burner rating

Rotisserie burner rating

(“300” Series only)

Approximate shipping weight

300 Series Models:

120VAC/60HZ - 3’ ( 91.4 cm) power cord supply cord with 3-prong grounded plug attached to grill

120VAC/60HZ - 2’ (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor

25,000 BTU Nat./22,500 BTU LP (7.3 kW Nat./6.5 kW LP)

325 lbs.

(147 kg)

(1) 15,000 BTU Nat./13,500 BTU LP

(4.4 kW Nat./4.0 kW LP)

340 lbs.

(154 kg)

5

Dimensions

(30" & 42" 500 Series Grills)

30" 500 Series Grill

29-1

/2”

cm

)

16-5

/8”

)

10-1

/4”

)

29-1

/2”

)

32

(83

-3/

.2 c

4” m)

42" 500 Series Grill

41-3

/16”

)

16-5

/8”

)

10-1

/4”

)

41-3

/16”

) 32

-3/

4”

(83

.2 c m)

6

Specifications

(30" & 42" 500 Series Grills)

Description

Cutout width

Cutout depth

Cutout height

Overall width

Overall depth

Gas requirements

30”W & 42”W 500 Series Grills

VGBQ53002RE

VGBQ54203RE/

VGIQ54203RE

28-5/8” (72.7cm) 40-1/4” (102.2cm)

28” (71.1 cm)

10-1/4” (26.0 cm)

29-1/2” (74.9 cm) 41-3/16” (104.6 cm)

32-3/4” (83.2 cm)

Natural: standard residential 1/2” (1.3 cm) ID gas service line.

LP/Propane: equipped with high capacity hose/regulator assembly for connection to standard 5gal, 20 lb. LP/Propane gas cylinder with

Type 1, QCC-1 connection or standard residential 1/2” (1.3 cm)

ID gas service line.

Electrical requirements

Grill burner rating

TruSear™ burner rating

(If applicable)

Rotisserie burner rating

Approximate shipping weight

120VAC/60HZ - 3’ ( 91.4 cm) power cord supply cord with 3-prong grounded plug attached to grill

120VAC/60HZ - 2’ (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor

29,000 BTU Nat./28,000 BTU LP (7.3 kW Nat./6.5 kW LP)

NA 30,000 BTU Nat./LP

(8.3 kW Nat./LP)

325 lbs.

(147 kg

15,000 BTU Nat./13,500 BTU LP

(4.4 kW Nat./4.0 kW LP)

350 lbs.

(159 kg)

7

Dimensions

(54" 500 Series Grill)

54” 500 Series Grill

50”

cm

) 16-5

/8”

)

10-1

/4”

)

53-3

/16”

)

32

-3/

4”

(83

.2 c m)

8

Specifications

(54" 500 Series Grill)

Description

Cutout width

Cutout depth

Cutout height

Overall width

Overall depth

Gas requirements

Electrical requirements

Grill burner rating

TruSear™ burner rating

(If applicable)

Rotisserie burner rating

Approximate shipping weight

54”W 500 Series Grills

VGBQ55404RE/VGIQ55404RE

52-1/4” (132.7 cm)

28” (71.1 cm)

10-1/4” (26.0 cm)

53-3/16” (135.1 cm)

Natural:

32-3/4” (83.2 cm) standard residential 1/2” (1.3 cm) ID gas service line.

LP/Propane: equipped with high capacity hose/regulator assembly for connection to standard 5gal, 20 lb. LP/Propane gas cylinder with Type 1, QCC-1 connection or standard residential 1/2” (1.3

cm) ID gas service line.

120VAC/60HZ - 3’ ( 91.4 cm) power cord supply cord with 3-prong grounded plug attached to grill

120VAC/60HZ - 2’ (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor

29,000 BTU Nat./28,000 BTU LP (7.3 kW Nat./6.5 kW LP)

30,000 BTU Nat./LP (8.3 kW Nat./LP)

15,000 Nat./13,500 BTU LP

(4.4 kW Nat./4.0 kW LP)

490 lbs.

(222 kg)

9

General Information

• Keep grill area clear and free from combustible materials, gasoline, and other flammable vapors.

• When the outdoor grill is not in use, the gas supply must be turned off at the LP gas supply cylinder.

• The pressure regulator and hose assembly supplied with the outdoor grill must be used.

Replacement pressure regulators and hose assemblies must be those specified by the manufacturer.

• Finding a leak is not a “do-it-yourself” procedure. Some leaks can only be found with the burner control in the on position and this must be done by a qualified technician.

• The LP supply cylinder to be used must be constructed and marked in accordance with the specifications for LP- gas cylinders of the

U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-

B339, Cylinders, Spheres, and Tubes for the

Transportation of Dangerous Goods.

• Use only extension cords with a 3-prong grounding plug, rated for the power of the equipment, and approved for outdoor use with a W-A marking.

• Gas Manifold Pressure–

Natural gas - 4.0” W.C.P.

LP/Propane - 10.0” W.C.P.

WARNING

If the following instructions are not followed exactly, a fire causing death or serious injury may occur:

• Do not store a spare LP gas cylinder under or near this appliance.

• Never fill the cylinder beyond 80 percent full.

WARNING

This outdoor gas grill is not intended to be installed inside a home or on recreational vehicles and/or boats.

WARNING

Keep electrical supply cord and the fuel supply hose away from heated surfaces.

WARNING

This appliance is not fused. Installer must install a ground fault interrupt.

WARNING

This appliance is not fused. Installer must install a ground fault interrupt.

General Information

• A minimum of 6” (15.2 cm) from the sides, or a minimum of 8” (20.3 cm) from the right side if there is a rotisserie motor and a minimum of 24” (61.0 cm) from the back must be maintained from the grill above the cooking surface to adjacent vertical combustible construction. The grill is not to be located under overhead unprotected combustible construction.

• A minimum of 3” (7.6 cm) clearance from the back of the grill with a canopy and a minimum of 6” (15.2 cm) from the back of the grill without a canopy to noncombustible construction is required for the purpose of allowing the lid to open fully and for proper ventilation.

• Note that the grill exhausts combustion products and cooking greases to the back.

Never locate the grill in a location where the exhaust is directed at a window, less than 24” (61.0 cm) to combustible material or any surface that is difficult to clean.

• It is desirable to allow at least 6” side clearance to non-combustible construction above the cooking surface for counter space. If using the rotisserie option, the space is essential for motor and skewer clearance. The grill can be placed directly adjacent to combustible and/or noncombustible construction below the cooking surface.

• When determining a suitable location for the grill, take into account concerns such as exposure to wind, proximity to traffic paths and keeping gas supply lines as short as possible. Locate the grill only in a well-ventilated area. Never locate the grill in a building, garage, shed or other such fully enclosed areas. During heavy use, the grill will produce a lot of smoke. Ensure there is adequate area for it to dissipate.

300 and 500 Series Grills:

• When using a rear wall, locate a 110/120 volt supply outlet on the bottom left hand side beneath the solid bottom support at a maximum distance of 2 feet. This connection is to be used for the ignition system and canopy lights. In addition, the rotisserie motor requires a separate

110/120 volt supply to be located on the right hand side of the grill. Both the power supply cords for the ignition/lights and the rotisserie motor are equipped with a 3-prong (grounded) plug for protection against shock hazard. Do not cut or remove the grounding from the plug. The electrical service must be equipped with a properly grounded 3prong receptacle as required by the

National Electrical Code ANSI/NFPA 70latest edition. Installation in Canada must be in accordance with the Canadian

Electrical Code, CSA 22.1 and local codes.

IMPORTANT: Gas fittings, regulator, and installer supplied shut-off valve must be easily accessible.

11 10

Clearance Dimensions

(100 and 300 Series 30”W. Grill)

VGBQ1302/VGBQ3302RE

22-1

(58.3

5/16

)

16-5

/8”

)

6”

cm

)

10-5

/8”

)

29-1

/2”

)

5-3/

8”

cm

)

8”

cm

)

(73

29

.6 c m)

/16

27

-13

(70

.6 c m)

3” min

.

(7.6

cm

) to

no ncom bu sta fac e ble

24

” m in.

(61

.0 c m) to com bu sur sta ble fac e

Clearance Dimensions

(100 and 300 Series 36”W. Grill)

VGBQ1363/VGBQ3363RE

22-1

(58.3

5/16

cm

)

34-1

/4”

cm

)

16-5

/8”

)

10-5

/8”

)

6”

cm

)

29

(73

.6 c m)

/16

27

-13

(70

.6 c m)

5-3/

8”

cm

)

8”

cm

)

3” min

.

(7.6

cm

) to

no ncom bu sta fac e ble

24

” m in.

(61 com

.0 c bu sur fac e to m) sta ble

13 12

Clearance Dimensions

(500 Series 30”W. Grill)

VGBQ53002RE

22-1

(58.3

5/16

cm

)

16-5

/8”

)

10-1

/4”

)

6”

cm

)

29-1

/2”

cm

)

5-3/

8”

cm

)

8”

cm

)

32

(83

-3/

.2 c

4” m)

16

31

-9/

(80

.2 c m)

3” min

.

(7.6

cm

) to

no ncom bu sta fac e ble

24

” m in.

(61

.0 c m) to com bu sur sta ble fac e

14

Clearance Dimensions

(500 Series 42”W. Grill)

VGBQ54203RE/VGIQ54203RE

22-1

(58.3

5/16

cm

)

16-5

/8”

)

10-1

/4”

)

6”

cm

)

41-3

/16”

)

32

-3/

4”

(83

.2 c m)

16

31

-9/

(80

.2 c m)

5-3/

8”

cm

)

8”

cm

)

3” min

.

(7.6

cm

) to

no ncom bu sta fac e ble

24

” m in.

(61

.0 c m) to com bu sur sta ble fac e

15

16-5

/8”

)

10-1

/4”

cm

)

6”

cm

)

Clearance Dimensions

(500 Series 54”W. Grill)

VGBQ55404RE/VGIQ55404RE

22-1

(58.3

5/16

)

50”

cm

)

32

-3/

4”

(83

.2 c m)

16

31

-9/

(80

.2 c m)

5-3/

8”

cm

)

cm

) min

.

(7.6

3”

cm com bu sur

) to sta fac e

no ble n-

” m in.

24

(61 com

.0 c bu m) to sta fac e ble

16

Cutout Dimensions

(100 and 300 Series 30”W. Grill)

Gas inlet and power cord location area

(12.7

5”

cm

)

36”

cm

)

5”

(12

.7 cm

)

24

-3/

8”

(61

.9 c m)

*So sup lid b por t otto m

28-5

/8”

)

(7.6 c 3” m) m in.

Electrical connection for rotisserie motor

(position unit so that the plug is always accessible)

**A cces s do or o pen ing

Electrical connection for power supply cord on

300 Series to be located on rear wall with a maximum distance of 2’ (61.0 cm) beneath solid bottom support.

10-1

/4”

)

(1.2

1/2

)

1/

2”

(1.

2 c m)

Countertop typically requires

1/2” wide by 1/2” deep notch cutout on each side of grill.

This allows grill CP to sit back properly in the cutout.

*IMPORTANT

Cabinet cutout must have a solid bottom to support the full weight of the unit.

**Access Doors sold separately - refer to access door installation instructions for correct dimensions.

17

Cutout Dimensions

(100 and 300 Series 36”W. Grill)

Gas inlet and power cord location area

(12.7

5”

cm

)

5”

(12

.7 cm

)

24

-3/

8”

.9 c m)

(61

36”

cm

)

*So sup lid b por t m

35-1

/4” cm)

(7.6 c 3” m) m in.

Electrical connection for rotisserie motor

(position unit so that the plug is always accessible)

**A cces s do or o pen ing

Electrical connection for power supply cord on

300 Series to be located on rear wall with a maximum distance of 2’ (61.0 cm) beneath solid bottom support.

18

10-1

/8”

)

(1.2

cm

)

1/

2”

(1.

2 c m)

Countertop typically requires

1/2” wide by 1/2” deep notch cutout on each side of grill.

This allows grill CP to sit back properly in the cutout.

*IMPORTANT

Cabinet cutout must have a solid bottom to support the full weight of the unit.

**Access Doors sold separately - refer to access door installation instructions for correct dimensions.

Cutout Dimensions

(500 Series 30”W. Grill)

Gas inlet and power cord location area

(12.7

5”

cm

)

36”

cm

)

5”

(12

.7 cm

)

28

(71

.1 c m)

*So sup lid b por t otto m

28-5

/8”

)

(7.6 c 3” m) m in.

Electrical connection for rotisserie motor

(position unit so that the plug is always accessible)

Electrical connection for power supply cord on

**A cces s do or o pen ing

500 Series to be located on rear wall with a maximum distance of 2’ (61.0 cm) beneath solid bottom support.

10-1

/4”

)

(1.2

1/2

)

1/

2”

(1.

2 c m)

Countertop typically requires

1/2” wide by 1/2” deep notch cutout on each side of grill.

This allows grill CP to sit back properly in the cutout.

*IMPORTANT

Cabinet cutout must have a solid bottom to support the full weight of the unit.

**Access Doors sold separately - refer to access door installation instructions for correct dimensions.

19

Cutout Dimensions

Gas inlet and power cord location area

(12.7

5”

)

5”

(12

.7 cm

)

28

(71

.1 c m)

(500 Series 42”W. Grill)

40-1

/4”

)

(7.6 c 3” m) m in.

Electrical connection for rotisserie motor

(position unit so that the plug is always accessible)

36”

cm

)

Cutout Dimensions

(500 Series 54”W. Grill)

Gas inlet and power cord location area

(12.7

5”

cm

)

5”

(12

.7 cm

)

28

(71

.1 c m)

52-1

/4”

)

Electrical connection for rotisserie motor

(position unit so that the plug is always accessible)

(7.6 c 3” m) m in.

*So lid b otto m s upp ort

36”

cm

)

Electrical connection for power supply cord on

500 Series to be located on rear wall with a maximum distance of 2’ (61.0 cm) beneath solid bottom support.

**A cces s do or o pen ing

*IMPORTANT

Cabinet cutout must have a solid bottom to support the full weight of the unit.

**Access Doors sold separately - refer to access door installation instructions for correct dimensions.

*So lid b otto m s upp ort

10-1

/4”

)

20

(1.2

1/2

)

1/

(1.

2”

2 c m)

Countertop typically requires

1/2” wide by 1/2” deep notch cutout on each side of grill.

This allows grill CP to sit back properly in the cutout.

Electrical connection for power supply cord on

500 Series to be located on rear wall with a maximum distance of 2’ (61.0 cm) beneath solid bottom support.

**A cces s do or o pen ing

*IMPORTANT

Cabinet cutout must have a solid bottom to support the full weight of the unit.

**Access Doors sold separately - refer to access door installation instructions for correct dimensions.

21

10-1

/4”

) (1.2

1/2

)

1/

2”

(1.

2 c m)

Countertop typically requires

1/2” wide by 1/2” deep notch cutout on each side of grill.

This allows grill CP to sit back properly in the cutout.

Ventilation for Built-In Installations When

Using an Enclosed LP-Gas Cylinder

Not more than 5.00 inches from inside bottom of countertop.

5.00 inch maximum

Vents

5.00 inch maximum

All vents no more than 5.00 inches above the floor of the installation.

1.00 inch maximum

Bottom Vent not more than 1.00 inch from inside floor of installation.

Vents located on sidewall

An enclosure for an LP-gas cylinder shall be ventilated by openings at both the upper and lower levels of the enclosure. The effectiveness of the opening(s) for purposes of ventilation shall be determined with the

LP-gas supply cylinder in place. This shall be accompanied by one of the following: a.

One side of the enclosure shall be completely open; or b.

For an enclosure having four sides, a top and a bottom:

1. At least two ventilation openings (See Part IV, Definitions) shall be provided in the side walls of the enclosure, located within 5 in. (217 mm) of the top of the enclosure, equally sized, spaced at a minimum of 90 degrees (1.57 rad), and unobstructed. The opening(s) shall have a total free area of not less than 1 in2/lb (1.42 cm2/kg) of stored fuel capacity.

2. Ventilation opening(s) shall be provided at floor level at rear of the enclosure and shall have a total free area of not less than 1/2 in2/lb (7.1 cm2/kg) of stored fuel capacity. The bottom of the openings shall be 1 in. (25.4 mm) or less from the floor level and the upper edge no more than 5 in. (127 mm) above the floor level. The openings shall be equally sized, spaced at a minimum of 90 degrees (1.57 rad) and unobstructed.

3. Every opening shall have minimum dimensions so as to permit the entrance of a 1/8 inch (3.2 mm) diameter rod.

4. Ventilation openings in the side walls shall not communicate directly with other enclosures of the outdoor cooking gas appliance.

22

WARNING

Gas Connection

Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the grill rating plate agrees with that of the supply.

Never connect an unregulated gas line to the appliance. An installer supplied gas shut-off valve must be installed in an easily accessible location.

All installer supplied parts must conform to local codes, or in the absence of local codes, with the

National Electrical Code, ANSI/NFPA 70 and the

National Fuel Code, ANSI Z223.1/NFPA 54.

In Canada: Installation must be in accordance with the current CSA-B149.1, Natural Gas

Installation Code or CSA-B149.2, Propane

Installation Code and/or local codes. All pipe sealants must be an approved type and resistant to the actions of LP gas. Never use pipe sealant on flare fittings. All gas connections should be made by a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation must comply with the National Fuel Gas Code ANSI

Z223.1/NFPA 54. The gas grill and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2

PSIG (3.5 kPa). The gas grill must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that system at test pressures equal to or less than 1/2 psi (3.5 kPa). Built-in installations must be plumbed using a fixed/hard line if the unit is going to be operated at a distance exceeding 3 feet (0.91 meters) from the fuel supply per ANSI Z21.24 CSA.

Gas Conversion

To convert a grill from natural to

LP/Propane or LP/Propane to natural, you

MUST use conversion kit sold seperately.

CAUTION

Conversions should only be performed by an authorized service technician.

Electrical Connection

WARNING

ELECTRICAL SHOCK HAZARD

This appliance is equipped with a 3’

(91.4 cm) 3-prong power cord with a grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle. Do not cut or remove the grounding prong from this plug. This unit is not fused and installer must install a GFI. Unit must be

FOR YOUR SAFETY the Canadian Electrical Code, CSA C22.1.

23

Natural Fixed Piping Connection

Check with your local gas utility company or with local codes for instructions on installing gas supply lines. Be sure to check on type and size of run and how deep to bury the lines. If the gas line is too small, the grill will not function properly.

To connect the supplied regulator assembly to the incoming flexible gas line, attach with a 7/8”

(2.2 cm) female flare adapter to the 7/8” (2.2 cm) male flare adapter on the regulator assembly.

Ensure that the regulator arrow points in the direction of the gas flow towards the unit and away from the supply. Attach the regulator assembly to the grill unit by pulling back the female coupler sleeve towards the regulator.

Insert the coupler into the male coupler fitting on the grill until the sleeve snaps forward securing the connection. Do not forget to place the installer supplied gas valve in an accessible location.

Note: If using a Viking GSH12 flexible hose, remove the 1/2” flare adapter and attach hose to the 7/8” (2.2 cm) male flare on the regulator assembly.

female coupler

7/8” male flare adapter

Regulator

Assembly

Installer supplied flexible gas line with 1/2” female adapter or Viking

GHS12

Installer supplied shut-off valve must be easily accessible

Connection

Standard Residential 1/2" ID gas service line - 1/2" NPT male with

7/8" (2.2 cm) flare adapter.

Operating Pressure

4.0" W.C.P. Nat.

Supply Pressure

6" to 10" W.C.P. Nat. If in excess of 10" W.C.P., a step-down regulator is required.

24

LP/Propane Fixed Piping Connection

Check with your local gas utility company or with local codes for instructions on installing gas supply lines. Be sure to check on type and size of run and how deep to bury the lines. If the gas line is too small, the grill will not function properly.

To connect the supplied regulator assembly to the incoming flexible gas line, attach with a 3/8” female flare adapter to the 3/8” male flare adapter to the regulator assembly. Ensure that the regulator arrow points in the direction of the gas flow towards the unit and away from the supply. Attach the regulator assembly to the grill unit with the 3/8” female flare adapter on the regulator assembly to the 3/8” male flare adapter on the grill. Do not forget to place the installer supplied gas valve in an accessible location

3/8” female flare adapter

3/8” male flare adapter

Regulator

Assembly

Installer supplied flexible gas line with 3/8” female adapter or Viking

GHS12

Installer supplied shut-off valve must be easily accessible

Connection

Standard Residential 1/2" ID gas service line - 1/2” NPT male with

3/8" flare adapter.

Operating Pressure

10.0" W.C.P. LP/Propane

Supply Pressure

11" to 14" W.C.P. LP. If in excess of 14" W.C.P., a step-down regulator is required.

25

LP/Propane Tank Requirements

A dented or rusty LP/Propane tank may be hazardous and should be checked by your tank supplier. Never use a cylinder with a damaged valve. All tanks should be equipped with an OPD

(overfilling protection device). This is a DOT requirement for all tanks purchased after

October 1, 1998 and will ensure that the tank is not overfilled. The LP/Propane tank should be a standard 5-gal, 20 lb. gas cylinder tank approximately 12” in diameter and 18” high which must be constructed and marked in accordance with the Specifications for LP/Propane

Gas Cylinders of the U.S. Department of

Transportation (D.O.T.) or the National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes for Transportation of Dangerous

Goods; and Commission. The cylinder connection device must be compatible with the Type 1,

QCC-1 connector on the outdoor cooking appliance.

All LP/Propane tanks must be mounted in a vertical position for proper ventilation. The cylinder must be provided with a shut-off valve terminating in an LP/Propane gas supply cylinder valve outlet specified. The cylinder supply system must be arranged for vapor withdrawal and provided with a listed overfilling prevention device. If the appliance is stored indoors the cylinder must be disconnected and removed from the appliance. Each tank is supplied with a dust cap. Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane. The cylinder used must include a collar to protect the cylinder valve. Cylinders must be stored outdoors in a well-vented area out of the reach of children.

Built-In Installations

Built-in installations must be plumbed using a fixed/hard line if the unit is going to be operated at a distance exceeding 3 feet (0.91 meters) from the fuel supply per ANSI Z21.24 CSA. Also, in a built-in construction where an LP/Propane tank is going to be used, there MUST be some type of support (braces, cutout, etc.) to prevent tank from moving within the installation. The support must also allow the LP/Propane tank to withstand a horizontal tipping force equal to the weight of the tank without tipping over. The tank can not tip over or deflect more than 1.00 inch when a

8 lb. horizontal force is applied to a 20 lb.

LP/Propane tank

26

LP/Propane Tank Connection

Outdoor grills orificed for use with LP/Propane gas come equipped with a high capacity hose/regulator assembly for connection to a standard 20 lb. LP/Propane cylinder equipped with a Type 1, QCC-1 connector. Hose assembly must comply with Elastomeric Composite Hose and Couplings for conducting Propane and

Natural Gas, CAN/CGA-8.1 standard or the

Theromplastic Hose and Hose Couplings for conducting Propane and Natural Gas connection between the regulator and the

Type 1, QCC-1 fitting for leaks with a soapy water solution. If bubbles appear, tighten the connection. Repeat until all leaks have been stopped. ALWAYS CHECK FOR LEAKS AFTER

EVERY LP/PROPANE TANK CHANGE. Any joint sealant used must be an approved type and be resistive to the actions of LP/Propane gas.

3/8” female flare adapter

3/8” male flare adapter

Regulator

Assembly

CAN1-8.3 standard.

(See LP/Propane tank requirements below). Each tank is supplied with a dust cap. Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.

Connect the regulator to the grill unit by screwing the 3/8” flare coupling to the 3/8” flare adapter. Connect to the tank valve by screwing the Type 1, QCC-connector to the LP/Propane tank. Open the tank valve and check the

Connection

1/2” (1.3 cm) NPT male with a 3/8” (.95) flare adapter

NOTE: Tank must be mounted in vertical position for proper Ventilation

Operating Pressure

10.0” W.C.P. LP/Propane.

Type 1,

QCC-1 connector

27

WARNING

DANGER

Leak Testing

Although all gas connections on the grill are leak tested at the factory prior to shipment, a complete gas tightness check must be performed at the installation due to possible mishandling in shipment or excessive pressure unknowingly being applied to the unit. Periodically check the whole system for leaks, or immediately check if the smell of gas is detected.

• Do not smoke while leak testing.

• Extinguish all flames.

• Never leak test with an open flame

CAUTION

Before placing into operation, always check for gas leaks with a soapy water solution. DO NOT

USE AN OPEN FLAME TO CHECK FOR LEAKS.

1 2

FOR YOUR SAFETY

OFF

Make a soap solution of one part liquid detergent and one part water. You will need a spray bottle, brush or towel to apply the solution to the fittings.

Note: For LP/Propane units, check with a full cylinder.

3

Check that all control knobs are in the “OFF” position.

4

Apply the soap solution to fittings.

28

Turn cylinder valve knob counter clockwise one turn to open.

5 6

Bubbling bubbles in the soap solution indicates that a leak is present.

7

Stop a leak by tightening the loose joint or by replacing the faulty part with a replacement part recommended by the manufacturer.

1

8

2

Do not attempt to repair the cylinder valve if it should become damaged. The cylinder must be replaced.

If you are unable to stop a leak, shut off the gas at the cylinder valve. Remove the cylinder from the grill.

9

Call an authorized gas appliance service technician or LP/Propane gas dealer.

Do not use the grill until the leak is corrected.

29

1

OFF

2

After checking for leaks, push in and turn any control knob to release the pressure in the hose and manifold.

Turn off the control knob.

Burner Adjustment

Each burner is tested and adjusted at the factory prior to shipment; however, variations in the local gas supply may make it necessary to adjust the burners. The flames of the burners (except the rotisserie infrared burner) should be visually checked and compared with the following illustrations.

CORRECT YELLOW BLUE LIFTING

Flames should be blue and stable with no yellow tips, excessive noise or lifting. If any of these conditions exist, check if the air shutter or burner ports are blocked by dirt, debris, spider webs, etc. With a proper flame height, adjust the air shutter to obtain a blue flame with no yellow tipping that sits on the burner at the burner ports.

The air shutter is locked in place by a set screw which must be loosened prior to lighting the burner for adjustments.

1 2

3

To access the air shutter on the grill burners, remove the drip tray.

Remove the knobs and valve panel.

Note: Leave wires connected to switches on valve panel.

4

2

1

HI/L

ITE

With a screw driver, loosen the lock-screw on the face of the air shutter.

30

Push and turn the the valve to light the burner and adjust according to the directions following.

Note: By replacing the knob, it may be easier to light the burner.

5 6

3

CORRECT

YELLOW

BLUE LIFTING

"

cm

)

1/2

"

cm

)

If the flame is yellow, turn the air shutter counter clockwise to allow more air to the burner. If the flame is noisy and lifting away from the burner, turn the air shutter clockwise to reduce the amount of air to the burner.

7

1

Off

2

Once adjusted, turn the burner off, tighten the set screw on the air shutter. For grill burners, replace the valve panel and knobs.

Replace the drip tray

31

Rotisserie System

The rotisserie motor is attached to the mounting bracket located on the right side of the grill frame. The rotisserie motor must be electrically grounded in accordance with local codes. The skewer for the rotisserie is assembled into the gear box assembly by placing the pointed end into the gear box, and resting the threaded end on the support at the left side of the grill. With the skewer pushed as far in as possible, the grooved skewer bushing should rest on the left side bracket. Do not remove the plastic cover on the rotisserie motor switch due to safety consideration.

WARNING

ELECTRICAL SHOCK HAZARD

This appliance is equipped with a grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle. Do not cut or remove the grounding prong from this plug.

Groove skewer support

32

Skewer

Gear box

Mounting bracket

Grounded plug

Performance Checklist

A qualified installer should carry out the following checks:

• All internal packaging removed.

• Specified clearances maintained to combustible materials.

• Pressure regulator connected and set.

• Manual shut-off valve installed and accessible.

• Check air shutter adjustment - sharp blue flame, no yellow tipping.

• Check for gas leaks (odors) at all gas connections.

• Each burner lights satisfactorily, individually or with adjacent burners lit.

Any adjustments necessary that are the result of the installer not following instructions will be responsibility of the installer, dealer or the end user of the product.

Final Preparation

• Some stainless steel parts may have a plastic protective wrap which must be peeled off. The interior should be washed thoroughly with hot, soapy water to remove film residues and any dust or debris before being used, then rinsed and wiped dry. Solutions stronger than soap and water are rarely needed.

• All stainless steel body parts should be wiped with hot, soapy water and with a liquid cleaner designed for this material. If buildup occurs, do not use steel wool, abrasive cloths, cleansers, or powders!

If it is necessary to scrape stainless steel to remove encrusted materials, soak with hot, wet cloths to loosen the material, then use a wool or nylon scraper. Do not use a metal knife, spatula, or any other material tool to scrape stainless steel! Scratches are almost impossible to remove..

33

Service & Registration

Only authorized replacement parts may be used in performing service on the appliance.

All servicing should be referred to a qualified technician.

Contact Viking Range Corporation, 1-888-VIKING1 (845-4641), for the nearest service parts distributor in your area or write to:

VIKING RANGE CORPORATION

PREFERRED SERVICE

1803 Hwy 82W

Greenwood, Mississippi 38930 USA

The serial number and model number for your appliance are located on the identification plate mounted on the bottom left side of the door opening.

Record the following information indicated below. You will need it if service is ever required.

Model number ____________________________________________________________________________________

Serial number _____________________________________________________________________________________

Date of purchase __________________________________________________________________________________

Date installed ______________________________________________________________________________________

Dealer's name _____________________________________________________________________________________

Address ___________________________________________________________________________________________

These installation instructions should remain with the unit for future reference.

34 35

Notes

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

36

Notes

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________

37

advertisement

Key Features

  • Safety instructions
  • Clearance dimensions
  • Cutout dimensions
  • Gas and electrical connection
  • LP/propane tank requirements
  • Leak testing
  • Burner adjustment
  • Rotisserie system
  • Performance checklist
  • Service and registration

Frequently Answers and Questions

What type of gas supply can I use with the grill?
You can use either natural or LP/propane gas. Make sure the grill rating plate matches the type of gas supply you have.
What are the clearance requirements for my grill?
The guide provides detailed clearance dimensions for each model. Ensure you maintain the minimum clearance from combustible materials to prevent fire hazards.
How do I connect the gas supply to the grill?
The instructions cover both natural gas and LP/propane connections. Follow the step-by-step guide for proper connection to ensure safety and functionality.
What are the requirements for the LP/propane tank?
The guide clarifies the types of tanks, their size, and the required connections. Ensure you use the correct tank and follow the connection instructions.
How do I adjust the burners on my grill?
The guide provides illustrated directions for adjusting the burners to ensure proper flame height and stability. Adjust the air shutter to achieve a blue flame with no yellow tipping.
How do I use the rotisserie system?
The guide provides instructions for assembling and using the rotisserie system, which allows you to roast food evenly.

Related manuals