Tower and Obstruction Lighting Controls

Tower and Obstruction Lighting Controls
Series Included
Tower & Obstruction Lighting Controls
136
Beacon Flasher
FA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137
FS155- . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137
FS165- . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137
Lamp Monitors
Incandescent Lamps
FB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138
SCR490D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
SCR430T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140
SCR630T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140
LED Lamps
FB9L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141
SCR9L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142
Photo Controls
PCR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143
www.ssac.com • 800-843-8848 • fax: 605-348-5685
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Beacon Tower Flasher
FS & FA Series
B-KON Flashers have proven their reliability
through years of use on communication towers,
smoke stacks, cooling towers, tall buildings,
bridges and utility towers. The highest quality
components are encapsulated in a rugged plastic
housing with a molded-in heat transfer plate. The
flash rate, ratio, and fail-safe design meet FAA
regulations. Zero voltage switching can increase
lamp life up to ten times. The FS155-30RF &
FS165-30RF include superior RF filtering circuitry
for use in high RF installations; including AM hot
towers .
For more information see:
Appendix B, page 165, Figure 4 for dimensional drawing.
Appendix C, page 171, Figure 30 for connection diagram.
Operation
FS Series - Flasher (OFF First)
FA Series - Flashers & Aux. Modules
Upon application of input voltage, the T2 OFF time begins.
At the end of the OFF time, the T1 ON time begins and the
load energizes. At the end of T1, T2 begins and the load
de-energizes. This cycle repeats until voltage is removed.
Reset: Removing input voltage resets the output and the
sequence to T2 .
Features:
• Zero voltage switching - up to 10 times
longer lamp life
• No RFI caused by contacts closing
• High inrush capability - up to 200A
• RF model for AM hot towers & other high
RF installations
• Auxiliary units for synchronous flashing or
constant line loading
Approvals:
(FS155 & FA155 models only)
Auxiliary Products:
• Quick connect to screw adaptor:
P/N: P1015-18
• Female quick connect:
P/N: P1015-13 (AWG 10/12)
P/N: P1015-64 (AWG 14/16)
P/N: P1015-14 (AWG 18/22)
Available Models:
FA155
FA155-2
FA165
FA165-2
FS155-30RF
FS155-30T
FS165-30T
If desired part number is not listed, please call us to
see if it is technically possible to build .
Order Table:
Input
120VAC
120VAC
230VAC
230VAC
120VAC
120VAC
230VAC
120VAC
230VAC
Wattage
2500W
2500W
5000W
5000W
2500W
3000W
5000W
2500W
5000W
Inrush
200A
200A
200A
200A
200A
300A
200A
200A
200A
Description
For High RF Radiation locations including AM Hot Towers
Standard Flasher
For High RF Radiation locations including AM Hot Towers
Standard Flasher
Auxiliary unit for synchronous operating of additional beacons
Auxiliary unit with optical isolation between input and load contacts
Auxiliary unit for sychronous operating of additional beacons
Auxiliary unit to provide constant line loading
Auxiliary unit to provide constant line loading
Part Number
FS155-30RF
FS155-30T
FS165-30RF
FS165-30T
FA155-2
FA155-3
FA165-2
FA155
FA165
Specifications
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single & multiple beacon flashing with
auxiliary modules
Flash Rate (FS Series Only) . . . . . . . . . . . . . . . . . . . 30 ±10 FPM
ON/OFF Ratio (FS Series Only) . . . . . . . . . . . . . . . 50 - 67% ON time; 33 - 50% OFF time
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 or 230VAC ±20%
AC Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . . 50/60Hz
Output Rating (Zero Voltage Switching) . . . . . . . 2500W @ 120VAC; 5000W @ 230VAC
Inrush Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200A peak for 1 cycle of AC line
Mounting* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Surface mount with one #10 (M5 x 0.8) screw
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 x 2 x 1.51 in. (50.8 x 50.8 x 38.4 mm)
Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.25 in. (6.35 mm) male quick connect terminals
Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Encapsulated
Operating / Storage Temperature . . . . . . . . . . . . -40° to 65°C / -40° to 85°C
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95% relative, non-condensing
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 3.9 oz (111 g)
* Note: Must be mounted to metal surface using the included heat sink compound. The
maximum mounting surface temperature is 90°C.
www.ssac.com • 800-843-8848 • fax: 605-348-5685
137
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Flasher & Incandescent Beacon Alarm Relay
The FB120A and FB230A are used to monitor the
operation of one two-lamp incandescent beacon
and one beacon flasher (or auxiliary module).
The flasher and lamps are monitored by sensing
the flow of current in the circuit. If the lamp(s) or
the flasher fail to operate properly, a solid-state
output and an isolated SPDT relay energize. When
connected to a site monitoring system, this unit
provides the remote beacon monitoring protection
required by the FAA/FCC. On a multiple beacon
structure, one unit is required for each two-lamp
incandescent beacon (one unit per beacon for
LED beacons) .
For more information see:
Appendix B, page 167, Figure 32 for dimensional drawing.
Appendix C, page 171, Figure 31 for connection diagram.
FB120A/FB230A
Features:
• Senses failed flashing incandescent beacon
lamps & beacon flashers
• Toroidal current sensing
• One isolated, 5A, SPDT alarm output
• Two 1A, solid-state line voltage alarm
outputs
• Trip delays prevent nuisance alarms
Available Models:
FB120A
FB230A
Operation
If one lamp in an incandescent beacon fails, the relay
and solid-state lamp failure outputs energize after 10s.
If the flasher fails in the ON or OFF condition, the relay
and the solid-state flasher failure output energizes after
6s. If both failures occur, all three outputs energize after
their trip delays.
Note: If both incandescent lamps fail, all three outputs will
energize. The relay and solid-state flasher failure output
energizes after 6s, and the solid-state lamp failure output
energizes after 10s.
Order Table:
Input
120VAC
230VAC
Lamp Type
Incandescent Beacon
Incandescent Beacon
Part Number
FB120A
FB230A
Specifications
Input Voltage
FB120A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120VAC ±15%
FB230A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230VAC ±15%
AC Line Frequency . . . . . . . . . . . . . . . . . . 50/60Hz
Lamp Socket Voltage . . . . . . . . . . . . . . . . . ±10%; 50/60Hz
Alarm Outputs
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 total - 1 relay, 2 solid state;
One isolated SPDT relay rated 5A resistive
Two solid-state line voltage outputs
rated 0.5A steady, 5A inrush
Lamp Failure Detection
FB120A . . . . . . . . . . . . . . . . . . . . . . . . . . . . For two 620W or 700W lamps
FB230A . . . . . . . . . . . . . . . . . . . . . . . . . . . . For two 500W or 700W lamps
Trip Delays
Flasher Failure . . . . . . . . . . . . . . . . . . . . . . Fixed at 6s; -0/+40%
138
Lamp Failure . . . . . . . . . . . . . . . . . . . . . . . Fixed at 10s; -0/+40%
LEDs
Lamp Failure (Red) . . . . . . . . . . . . . . . . . . Glows when one or both lamps fail
Flasher Failure (Red) . . . . . . . . . . . . . . . . . Glows when the flasher fails
Protection
Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . Encapsulated
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . Surface mount with two #6 (M3.5 x 0.6) screws
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . 3.5 x 2.5 x 1.75 in. (88.9 x 63.5 x 44.5 mm)
Termination . . . . . . . . . . . . . . . . . . . . . . . . 7 position barrier block for 20 AWG (0.5 mm2)
to 14 AWG (2.5 mm2) wire
Environmental
Operating / Storage Temperature . . . . . -40° to 60°C / -40° to 85°C
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 7 oz (198 g)
www.ssac.com • 800-843-8848 • fax: 605-348-5685
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Obstruction Lamp Alarm Relay
SCR490D
The SCR490D Series is used to provide remote
monitoring of steady burning incandescent marker
and obstruction lighting. Four onboard switches
allow operator programming for lighting systems
with two through nine lamps on a single AC
circuit. The SCR490D uses a toroidal sensor and
electronic circuitry to sense the failure of one or
more lamps .
For more information see:
Appendix B, page 167, Figure 32 for dimensional drawing.
Appendix C, page 171, Figure 32 for connection diagram.
Operation
When a lamp fails, the SCR490D senses a decrease in
current flow. Then, after a fixed time delay, it transfers
to its alarm mode. In alarm mode, the LED indicator, the
output relay (SPDT isolated contacts), and a non-isolated
solid-state output are energized. Replacement of the failed
lamps resets the alarm outputs and the LED indicator.
To prevent false alarm signals, power must be applied to
the SCR490D at the same time that lamps are energized.
Features:
• Senses failed obstruction lamps
• 2 - 9 steadily burning lamps can be
monitored
• Toroidal current sensing
• Isolated, 10A, SPDT alarm output contacts
• 1A, solid-state line voltage alarm output
• 6 second trip delay prevents nuisance
alarms
Approvals:
Available Models:
SCR490D
Order Table:
Input
120VAC
Part Number
SCR490D
Specifications
Operation
Number of Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 9 (selectable)
Lamp Wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116W, incandescent lamps
Rated Lamp Voltage . . . . . . . . . . . . . . . . . . . . . . . . . 120 or 130VAC (selectable)
Monitored Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . 120VAC ±3%
Trip Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 6s fixed
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120VAC
AC Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . 50/60Hz
Tolerance
120VAC . . . . . . . . . . . . - 20% - 10%
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Surface mount with two #6 (M3.5 x 0.6)
screws
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5 x 2.5 x 1.75 in. (88.9 x 63.5 x 44.5 mm)
Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Screws with captive clamps for up to
14 AWG (2.45 mm2) wire
Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Encapsulated
Operating / Storage Temperature . . . . . . . . . . . . . -40° to 65°C / -40° to 85°C
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95% relative, non-condensing
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 6.8 oz (193 g)
Line Voltage Output (Solid State Rated) . . . . . . . . ≤ 125W to operate a spare lamp or alarm
Isolated Alarm Output . . . . . . . . . . . . . . . . . . . . . . . 10A @ 120VAC or 30VDC resistive;
1/4 hp @ 125VAC; 1/2 hp @ 250VAC
www.ssac.com • 800-843-8848 • fax: 605-348-5685
139
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Universal Lamp Alarm Relay
SCR Series
The SCR series is a universal lamp alarm relay
designed to sense the failure of flashing or steady
incandescent beacon lamps or steady side lights.
The toroidal current sensor provides isolation and
allows monitoring of more than one line at a time.
The SCR Series energizes when one or more lamps
fail. It will monitor the operation of one to four
side lights and up to four beacon lamps.
For more information see:
Appendix B, page 167, Figure 32 for dimensional drawing.
Appendix C, page 171, Figure 33 for connection diagram.
Operation
When a lamp fails, the SCR Series senses a decrease in
current flow. After a fixed time delay, the LED glows
and the two alarm outputs energize. The outputs and the
LED are reset when the failed lamps are replaced and the
current returns to the nominal setting, or when the input
voltage is removed. The SCR will sense an open flasher,
it will not sense a continuously ON flasher (see FB Series).
Order Table:
Input
120VAC
230VAC
Lamp Type
Incandescent
Incandescent
Features:
• Monitors incandescent lamps for failure
• Senses failed flashing beacon or obstruction
lamps
• Switch selectable number, voltage, &
wattage of lamps
• Isolated, 10A, SPDT alarm output contacts
• 1A, solid-state line voltage alarm output
• Toroidal current sensing
Approvals:
(SCR430T only)
Available Models:
SCR430T
SCR630T
Part Number
SCR430T
SCR630T
Specifications
Lamp Monitoring
Capacity (in lamps) . . . . . . . . . . . . . . . . . . . . . . . . .100W 116W 620W 700W
SCR430T 120VAC Lamps . . . . . 4
4
4
n/a
SCR630T 230VAC Lamps . . . . . . n/a
4
n/a
4
Time Delay
Trip Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Factory fixed ≅ 6s
Input
Input Voltage/Tolerance . . . . . . . . . . . . . . . . . . . .SCR430T - 120VAC ±10%
SCR630T - 230VAC ±10%
AC Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . .50/60Hz
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .To operate a spare lamp or alarm
Line Voltage Output (Solid-state Rated) . . . . . . .≤ 125W @ 120VAC
≤ 250W @ 240VAC
Isolated Alarm Output (SPDT) . . . . . . . . . . . . . . .10A @ 240VAC or 30VDC resistive;
1/4 hp @ 125VAC; 1/2 hp @ 250VAC
140
Mechanical
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Two #6 (M3.5 x 0.6) screws
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.5 x 2.5 x 1.75 in. (88.9 x 63.5 x 44.5 mm)
Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Screws with captive clamps for up to
14 AWG (2.45 mm2) wire
Protection
Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Encapsulated
Environmental
Operating Temperature . . . . . . . . . . . . . . . . . . . . .-40° to 65°C
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≅ 6.8 oz (193 g)
www.ssac.com • 800-843-8848 • fax: 605-348-5685
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Universal Lamp Alarm Relay
FB9L
The FB series is a universal lamp alarm relay
designed to sense the failure of flashing LED
beacon lamps. It will monitor the operation of
one to eight beacons connected to a single flasher
and/or auxiliary modules and the operation of
the flasher. The FB Series output relay energizes
when one or more lamps fail. All monitored lamps
must be the same wattage and voltage. The 0.5A
solid-state output energizes when a flasher failure
is sensed .
For more information see:
Appendix B, page 167, Figure 32 for dimensional drawing.
Appendix C, page 171, Figure 31 for connection diagram.
Features:
• Senses failed flashing beacon lamps
• Switch selectable number of beacons
• Senses flasher failure
• Isolated, 10A, SPDT alarm output contacts
• 10A, NO line voltage alarm output
• 0.5A, solid-state flasher failure output “F”
• Self calibrating; no fine adjustment required
• Meets FAA-AC No: 150/5345-43E
Approvals:
Auxiliary Products:
• DIN mount adaptor:
P/N: P1023-20
• DIN rail: P/N: C103PM (Al)
Operation
When a LED beacon lamp fails, the FB senses a decrease in current flow. After a 10s lamp failure trip delay, the
isolated SPDT (4-5-6) and non-isolated SPNO (3-1) relay contacts energize. These contacts are used to indicate a
Available Models:
beacon failure has occurred. The “L” onboard LED indicator flashes green during the trip delay and glows red
after the output relay energizes. Connected to a site monitoring system, it provides remote beacon monitoring
FB9L
required by FAA-AC No: 150/5345-43E.
The FB also monitors the operation of the flasher. If the flasher remains in the ON or OFF condition for more than
6s the solid-state output energizes and the “F“ flasher failure, onboard LED glows red. This output is normally
used to energize an external flasher bypass relay. The contacts of the bypass relay are used to route voltage around
the failed flasher and to indicate an alarm condition.
Note: In a single flasher, single beacon system, if the beacon lamp fails, zero current flow is detected. This will
cause the flasher failure output to energize after 6s and then the beacon failure outputs after 10s. This is normal
operation and can be expected anytime zero current is flowing through the monitored conductor.
Calibration
The alarm relays must be calibrated after initial installation and each time the LED lamps are replaced. In order to calibrate or re-calibrate the alarm relay, the internal memory
must be cleared .
Clearing Memory:
Remove input voltage, transfer the calibration switch to the off position, re-apply input voltage. The LED will flash Red to indicate the memory is clear and the relay is ready
for calibration.
Calibration:
1) Perform visual inspection of the structure’s lighting to assure all lamps and flashers are operating properly.
2) Remove input voltage, and check to ensure the calibrate switch is in the OFF position. Adjust the lamp selector switches for the correct number of similar (see note a) lamps
to be monitored .
3) Reapply input voltage, the LED should flash Red. After confirming the LED is flashing Red and the lamp selector switches are properly adjusted, transfer the calibrate switch
from OFF to ON. The LED will alternately flash Red & Green. Within 30 seconds the LED will glow Green indicating input power is applied and the unit is calibrated. Leave the
calibrate switch in the ON position. Reapplying input voltage when this switch is in the ON position does not affect the calibration settings.
Calibration Failed:
4) If the relay is unable to establish trip points for the setup conditions within 60 seconds, the LED will double blink Red. Remove input voltage and repeat steps 2 and 3.
Notes:
a. Monitoring a mixture of LED beacons and LED obstruction lamps is not possible with the SCR9L.
b. This alarm relay is not designed to monitor incandescent lamps.
c. This alarm relay must be recalibrated each time an LED lamp is replaced.
d. Due to LED lamp aging, recalibration every 12 months is recommended.
e. Applying input voltage when the calibrate switch is in the OFF position, erases the previous calibration settings. The LED will flash Red. The output relays are OFF and the
unit will not sense lamp failures.
f. Only one (1) temperature compensated LED Beacon can be monitored with this product. A combination of temperature compensated and standard LED Beacons cannot be
monitored .
Indicator Table:
Order Table:
Input
120 - 230VAC
Beacon Type
LED
Part Number
FB9L
L
Green
Input ON & Calibrated
L
Green Flashing
Trip Delay
L
Red
Lamp Failure
L
Red/Green Flashing
Calibrating
L
Red Flashing
Not Calibrated
F
Red
Flasher Failure
Specifications
Sensors
Calibration Range (total all Lamps) . . . . . . . .
Absolute Max Current (total all Lamps) . . . .
Single Lamp Current . . . . . . . . . . . . . . . . . . . .
Trip Delay
Flasher Failure . . . . . . . . . . . . . . . . . . . . . . . . . .
Lamp Failure . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input
Input Voltage/Tolerance . . . . . . . . . . . . . . . . .
AC Line Frequency . . . . . . . . . . . . . . . . . . . . . .
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Line Voltage Output (SPNO) . . . . . . . . . . . . . .
150mA - 8.0A
15A max. (may not calibrate above 8A)
150mA - 8.0A (total all lamps < 8.0A)
Fixed at 6s; -0/+40%
Fixed at 10s; -0/+40%
120 to 230VAC / ±15%
50/60Hz
To operate a spare lamp or alarm
5A @ 240VAC or 30VDC resistive;
1/4 hp @ 125VAC; 1/2 hp @ 250VAC
Isolated Alarm Output (SPDT) . . . . . . . . . . . . 10A @ 240VAC or 30VDC resistive;
1/4 hp @ 125VAC; 1/2 hp @ 250VAC
www.ssac.com • 800-843-8848 • fax: 605-348-5685
Solid-state Line Voltage Output (F) . . . . . . . .
Mechanical
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LEDs
Power/Timing/Lamp Failure (Bi color) . . . .
Flasher Failure (Red) . . . . . . . . . . . . . . . . . . . . .
Protection
Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Environmental
Operating / Storage Temperature . . . . . . . . .
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0.5A steady; 5A inrush
One #10 (M5 x 0.8) screw
3 x 2 x 1.64 in (76.7 x 51.3 x 41.7 mm)
IP20 screw terminals for up to 14 AWG
(2.45 mm2) wire or two 16 AWG
(1.3 mm2)w ires
Glows red when one or more lamps fail
Glows red when the flasher fails
Encapsulated
-40° to 60°C / -40° to 85°C
≅ 3.9 oz (111 g)
141
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Universal Lamp Alarm Relay
SCR9L
The SCR series is a universal lamp alarm relay
designed to sense the failure of flashing or steady
LED beacon lamps or obstruction lamps. The SCR
Series energizes when one or more lamps fail. It
will monitor the operation of one to eight beacon
or obstruction lamps . All monitored lamps must
be the same wattage and voltage When connected
to a site monitoring system, it provides the remote
lamp monitoring protection required by the FAAAC No: 150/5345-43E.
For more information see:
Appendix B, page 167, Figure 32 for dimensional drawing.
Appendix C, page 172, Figure 35 for connection diagram.
Features:
• Monitors LED lamps for failure
• Senses failed flashing or steady beacon or
obstruction lamps
• Switch selectable number of lamps
• Isolated, 10A, SPDT alarm output contacts
• 5A, NO line voltage alarm output
• Self calibrating; no fine adjustment required
• Meets FA-AC No: 150/5345-43E
Approvals:
Available Models:
SCR9L
Operation
When a lamp fails, the SCR Series senses a decrease in current flow. After a 10s trip delay, the onboard LED
glows and the two alarm outputs energize. The outputs and the LED are reset when the failed lamps are replaced
and the unit is recalibrated. The SCR will sense an open flasher, it will not sense a continuously ON flasher (see
FB Series). Removing input voltage de-energizes the output and the LED‘s. It does not change the calibration.
Calibration
The alarm relays must be calibrated after initial installation and each time the LED lamps are replaced. In order to calibrate or re-calibrate the alarm relay, the internal memory
must be cleared .
Clearing Memory:
Remove input voltage, transfer the calibration switch to the off position, re-apply input voltage. The LED will flash Red to indicate the memory is clear and the relay is ready
for calibration.
Calibration:
1) Perform visual inspection of the structure’s lighting to assure all lamps and flashers (if used) are operating properly.
2) Remove input voltage, and check to ensure the calibrate switch is in the OFF position. Adjust the lamp selector switches for the correct number of similar (see note a) lamps
to be monitored .
3) Reapply input voltage, the LED should flash Red. After confirming the LED is flashing Red and the lamp selector switches are properly adjusted, transfer the calibrate switch
from OFF to ON. The LED will alternately flash Red & Green. Within 30 seconds the LED will glow Green indicating input power is applied and the unit is calibrated. Leave the
calibrate switch in the ON position. Reapplying input voltage when this switch is in the ON position does not affect the calibration settings.
Calibration Failed:
4) If the relay is unable to establish trip points for the setup conditions within 60 seconds, the LED will double blink Red. Remove input voltage and repeat steps 2 and 3.
Notes:
a. Monitoring a mixture of LED beacons and LED obstruction lamps is not possible with the SCR9L.
b. This alarm relay is not designed to monitor incandescent lamps.
c. This alarm relay must be recalibrated each time an LED lamp is replaced.
d. Due to LED lamp aging, recalibration every 12 months is recommended.
e. Applying input voltage when the calibrate switch is in the OFF position, erases the previous calibration settings. The LED will flash Red. The output relays are OFF and the
unit will not sense lamp failures.
f. Only one temperature compensated LED Beacon can be monitored with this product. A combination of temperature compensated and standard LED Beacons cannot be
monitored .
Indicator Table:
Order Table:
Input
120 - 230VAC
Lamp Type
LED
Part Number
SCR9L
L
Green
Input ON & Calibrated
L
Green Flashing
Trip Delay
L
Red
Lamp Failure
L
Red/Green Flashing
Calibrating
L
Red Flashing
Not Calibrated
Specifications
Sensors
Calibration Range (total all Lamps) . . . . . . . . . 150mA - 8.0A
Absolute Max Current (total all Lamps) . . . . . 15A max. (may not calibrate above 8A)
Single Lamp Current . . . . . . . . . . . . . . . . . . . . . 150mA - 8.0A (total all lamps < 8.0A)
Time Delay
Trip Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Factory fixed ≅10s
Input
Input Voltage/Tolerance . . . . . . . . . . . . . . . . . . 120 to 230VAC ±15%
AC Line Frequency . . . . . . . . . . . . . . . . . . . . . . . 50/60Hz
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . To operate a spare lamp or alarm
Line Voltage Output (SPNO) . . . . . . . . . . . . . . 5A @ 240VAC or 30VDC resistive;
1/4 hp @ 125VAC; 1/2 hp @ 250VAC
Isolated Alarm Output (SPDT) . . . . . . . . . . . . . 10A @ 240VAC or 30VDC resistive;
1/4 hp @ 125VAC; 1/2 hp @ 250VAC
142
Auxilliary Input Voltage (H) . . . . . . . . . . . . . . . < 2A @ 230VAC
Mechanical
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . One #10 (M5 x 0.8) screw
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 x 2 x 1.64 in (76.7 x 51.3 x 41.7 mm)
Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP20 screw terminals for up to 14 AWG
(2.45 mm2) wire or two 16 AWG (1.3 mm2)w ires
Protection
Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Encapsulated
Environmental
Operating / Storage Temperature . . . . . . . . . . -40° to 60°C / - 40° to 85°C
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 3.9 oz (111 g)
www.ssac.com • 800-843-8848 • fax: 605-348-5685
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Photo Control
PCR Series
Features:
The PCR Series of photo control is a combination
of precision electronic circuitry, electromechanical
output, and unique molded plastic housing.
Designed and built to meet the demands of
the most rigorous requirement of tower and
obstruction lighting control, each unit is factory
calibrated to meet FAA and FCC specifications.
Electronic circuit, output contactor, and terminal
block are all contained within front plastic
housing. Edge support molded into the bottom
edge of housing allows easy wiring of new and
existing installations. Available with or without
cast aluminum junction box.
• Automatic lighting circuit operation: dusk
to dawn
• Meets FAA/FCC requirements for
obstruction lighting
• Two 20A load contacts
• Direct replacement of popular photo
controls
• Time delay eliminates contact chatter
For more information see:
Appendix B, page 167, Figure 33 for dimensional drawing.
Appendix C, page 172, Figure 36 for connection diagram.
PCR10
PCR11
PCR12
PCR13
Available Models:
Operation
When the amount of light sensed falls below the actuation
level for energization, the output relay energizes.
Conversely, when the amount rises above the actuation
level for de-energization, the output relay de-energizes.
Order Table:
Input
120VAC
230VAC
120VAC
230VAC
Conversion Chart
Description
Photo Control without aluminum box
Photo Control without aluminum box
Photo Control with aluminum box
Photo Control with aluminum box
Part Number
PCR10
PCR12
PCR11
PCR13
REPLACES
Part
Number
Hughey &
Phillips
PCR11
PC800 120V
PEC52010
PCR13
PC800 240V
PEC52010-1
Crouse Hinds
Specifications
Indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LED indicates power is applied
Light Actuation Levels (Factory Calibrated) . . . . . Energized: ≤ 35 fc
De-energized: ≥ 60 fc
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120VAC or 230VAC
AC Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . 50/60Hz
Tolerance
120 & 230VAC . . . . . . . -20% - 10%
Output Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Two SPST NO 20A contacts
1 hp @ 120VAC
2.5 hp @ 240VAC
Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Screw terminals for up to #8 (M4 x 0.7) AWG wire
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ABS plastic housing with gasket seal.
Multiple knockout holes for optional mounting
to Crouse Hinds or Hughey & Phillips cast
aluminum electrical boxes.
www.ssac.com • 800-843-8848 • fax: 605-348-5685
143