The Bosch LTC-0485-21 is a high-performance 1/3-inch CCD camera with 15-bit digital signal processing for outstanding picture performance in all lighting conditions. It features three pre-programmed operation modes, noise elimination, true color reproduction, adaptive dynamic range optimization, Bilinx™ bi-directional coaxial communications, genlock including sub-carrier locking, and enhanced video motion detection.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
DinionXFFrontPage.fm Page 1 Friday, January 21, 2005 4:13 PM
Dinion
XF
– LTC 0610 & LTC 0485 series cameras
EN
Installation Instructions
15-bit digital color camera
FR
Manuel d’installation
Caméra numérique couleur
15 bits
DE
Installationshandbuch
15-Bit digitale Farbkamera
ES
Manual de instalación
Cámara digital en color de
15 bits
NL
Installatiehandleiding
15-bits digitale kleurencamera
IT
Manuale di installazione
Telecamera digitale a colori
15 bit
PT
ZH
Manual de Instalação
Câmara digital policromática de 15 bits
安装说明
15 位数码彩色摄像机
Dinion XF | Installation Manual
SAFETY PRECAUTIONS
EN | 3
Danger
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product's enclosure that may be of sufficient magnitude to constitute a risk to persons.
Warning
The exclamation mark within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Caution
To reduce the risk of electric shock, do not remove cover (or back). No user-serviceable parts inside. Refer servicing to qualified service personnel.
Important Safeguards
1. Read these instructions.
2. Keep these instructions.
3. Comply with all warnings.
4. Follow all instructions.
5. Do not use this equipment near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other equipment (including amplifiers) that produce heat.
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 4
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. Both the wide blade and the third prong are provided for your safety. If the supplied plug does not fit into your outlet, consult an electrician for advice.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the equipment.
11. Only use attachments/accessories specified by the manufacturer.
12. Unplug this equipment during lightning storms or when unused for long periods of time.
13. Refer all servicing to qualified service personnel. Servicing is required when the equipment has been damaged in any way, such as when power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the equipment, the equipment has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. An all-pole mains switch with a contact separation of at least 3mm in each pole shall be incorporated in the electrical installation of the building.
Warning
To reduce the risk of fire or electric shock, this apparatus should not be exposed to rain or moisture and objects filled with liquids, such as vases, should not be placed on this apparatus.
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 5
FCC Information
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
•
•
•
• particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/ TV technician for help.
Note
Any change or modification of the equipment, not expressly approved by
Bosch authorization, could void the user's authority to operate the equipment. For additional information or to speak to a representative, please contact the Bosch Security Systems location nearest to you or visit our web site at www.boschsecuritysystems.com
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 6
Introduction
The Dinion XF is a high-performance smart surveillance color camera. It incorporates 15-bit digital signal processing for outstanding picture performance under all lighting conditions. The Dinion XF is easy to install and ready to use, and offers the best solution for demanding scene conditions. Features include:
• Three pre-programmed operation modes
• Noise elimination, true color reproduction
• Adaptive dynamic range optimization
• Bilinx™ bi-directional coaxial communications
• Genlock including sub-carrier locking
• Enhanced video motion detection
Type number overview
Type number
Standard
Supply voltage
CCD type
LTC
0610/11
LTC
0610/21
PAL NTSC
24 VAC or 12 VDC
PAL NTSC
230 VAC 50Hz 110 VAC 60Hz
1/2"
LTC
0610/51
LTC
0610/61
Type number
Standard
Supply voltage
CCD type
LTC
0485/11
LTC
0485/21
PAL NTSC
24 VAC or 12 VDC
PAL NTSC
230 VAC 50Hz 110 VAC 60Hz
1/3"
LTC
0485/51
LTC
0485/61
Caution
Ensure that your power supply matches the rated voltage of your camera before installing.
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 7
Unpacking
Unpack carefully and handle the equipment with care. The packaging contains:
• Dinion XF camera
• CCD protection cap
• Spare lens connector (male)
• These instructions
Note
If equipment appears to have been damaged during shipment, repack it in the original packaging and notify the shipping agent or supplier.
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual
Connections
Power
Low voltage versions
10mm
VIDEO
DC 12V
AC 24V
SVHS
SYNC
ALARM
High voltage versions
VIDEO
SVHS
SYNC
ALARM
EN | 8
For low voltage cameras:
• push in the tabs to open the quick-connectors (these connections are not polarity sensitive).
• use AWG16 to 22 stranded wire or AWG16 to 26 solid wire; cut back
10mm (0.4") of insulation.
Composite video
VIDEO
DC 12V
AC 24V
SVHS
SYNC
ALARM
VIDEO
SVHS
SYNC
ALARM
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual
Sync
VIDEO
DC 12V
AC 24V
SVHS
SYNC
ALARM
Y/C
VIDEO
DC 12V
AC 24V
SVHS
SYNC
ALARM
Pin
3
4
1
2
Y/C socket
GND Y
GND C
Y
C
3
1
4
2
VIDEO
SVHS
SYNC
ALARM
VIDEO
SVHS
SYNC
ALARM
EN | 9
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 10
Alarm connector
Pin Alarm socket
Alarm
3
4
1
2
Ground
Alarm in
Relay out contact 1
Relay out contact 2
Pin 1 Pin 4
• Max. wire diameter AWG 22-28 for both stranded and solid
• Default relay position n.o. (normally open), no alarm
• Alarm output relay switching capability: Max voltage 30VAC or
+40VDC. Max 0.5 A continuous, 10VA.
• Alarm in: TTL logic, +5V nominal, +40VDC max, DC coupled with
22k
Ω pull-up to +3.3V
• Alarm in: configurable as active low or active high
• Max. 42V allowed between camera ground and each of the relay pins.
Lens mounting
The camera accepts both C and CS-mount lenses. DC-iris lenses are recommended for the best picture performance. The camera automatically detects the type of lens used and optimizes performance accordingly.
A spare male lens connector is provided.
Caution
To avoid damaging the CCD sensor when using a C-mount lens, turn the red back focus ring counterclockwise until it stops (see back focus adjustment) before mounting the lens.
Lenses weighing more than 0.5 kg (1.1lbs) must be separately supported.
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 11
Bosch
Bosch
Pin
3
4
1
2
Video iris lens
Supply (11.5V ±0.5, 50mA max.)
Not used
Video signal 1Vpp 1kOhm
Ground
DC iris lens
Damp -
Damp +
Drive +
Drive -
Note
If a short circuit is detected on the lens connector, the on-screen display
(OSD) failure message LENS SHORT CIRCUIT is shown. The lens circuit is automatically disabled to avoid internal damage. Remove the lens connector and check the pin connections.
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 12
Back focus adjustment
To optimize picture sharpness in both bright and low-level lighting, adjust the back focus. Use the camera's unique Lens Wizard (see Advanced Setup). This ensures that the object of interest always remains in focus even when focusing at the maximum lens opening.
When back focusing vari-focus lenses, adjust to obtain a sharp picture in both wide-angle and tele positions for both far and near focus.
When back focusing zoom lenses, ensure the object of interest remains in focus throughout the entire zoom range of the lens.
To adjust back focus:
1.
Open the slide door at the side of the camera
2.
Unlock the back focus locking button.
Bosch
Bosch
3.
Turn the back focus adjustment as required.
Bosch
4.
Lock the back focus locking button.
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 13
M ounting the camera
The camera can be mounted from the top or bottom. The bottom mounting is isolated from ground. With outdoor scenes, a DC-iris lens is recommended.
Caution
Do not point the camera/lens into direct sunlight.
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 14
Advanced Set-up
The Dinion XF normally provides an optimal picture without the need for further adjustments. However, advanced set-up options are available for getting the best results from the camera under special circumstances. There are two main menus; a Mode menu and an Installer menu.
The camera has three pre-programmed operating modes that can be selected in the Mode menu. These modes are pre-programmed by default but you can adjust them according to your preferences. The Mode menu allows you to select and set-up the picture enhancement functions for each mode. If you are not happy with your changes, you can always recall the default values for the mode.
The camera also has an Installer menu in which the installation settings can be set.
The Mode and Installer menus have functions that can be selected directly or submenus for more detailed set-up.
Accessing and navigating menus
Five keys, located behind the side panel, are used for navigating through the various menus.
To access the set-up menus, press the menu/select key (center).
Bosch
Bosch
The main menu appears on the OSD. Use the arrow keys for navigation.
When the Bilinx™ communications link is active, the buttons on the camera are disabled. You can also set up Bilinx™ so that the camera buttons remain disabled even when Bilinx™ is not actively controlling the camera. This prevents unauthorized change of the camera settings.
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual
Menu Structure
MODE
ALC
ENHANCE
COLOR
BLC
VMD
MODE ID
DEFAULTS
MODE x ALC
ALC LEVEL
SHUT/GAIN
PEAK / AVERAGE
ALC SPEED
MODE X ENHANCE
AUTO BLACK
BLACK LEVEL
CONTOUR
DNR
XF-DYNAMIC
MODE X COLOR
WHITE BALANCE
WBSPEED
R GAIN
G-GAIN
B-GAIN
SATURATION
MODE X BLC
BLC
BLC LEVEL
BLC AREA
MODE X VMD
VMD
AREA
ACTIVE
MOTION
SENSITIVITY
MODE X DEFAULTS
CONFIRM
Bosch Security Systems | 2003-10 | V0.5
EN | 15
MODE x SHUTGAIN
SHUTTER
DEFSHUT
SENS UP
GAIN
MAX GAIN
NIGHTSENSE
Dinion XF | Installation Manual
INSTALL
LENS WIZARD
I/O
SYNC
CAMERA ID
DEFAULTS
INSTALL LENS WIZARD
LENS TYPE
DETECTED
SET BACK FOCUS
SET LEVEL
INSTALL I/O
SYNC INPUT
COMMUNICATION
CABLE COMP
COMP LEVEL
ALARM
INSTALL SYNC
SYNC
DETECTED SYNC
V PHASE
H PHASE
SUB PHASE
INSTALL CAMERA ID
CAMERA ID
ID POSITION
MAC ADDRESS
EN | 16
INSTALL I/O ALARM
ALARM IN
ACTIVE
ACTION
ALARM OUT
ALL DEFAULTS
CONFIRM
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual
Hints for menu navigation
How to use the 5 keys
Up key
EN | 17
Menu/select key
Left key Right key
Lock
Down key
• Press the menu/select key to access the menus or to move to the next or previous menu.
• Press the menu/select key for approximately 1.5 seconds to open the
Installer menu.
• Use the up or down keys to scroll up or down through a menu.
• Use the left or right keys to move through options or to set parameters.
• When in a menu, quickly pressing the menu/select key twice restores the selected item to its factory default.
• To close all menus at once from any menu, select the Exit item and hold down the menu/select key until the menu display disappears.
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 18
Mode menu
Function Selection
MODE
ALC
1, 2, 3
Select submenu
ENHANCE Select submenu
Description
Select operating mode
Select to access the video level control menu
Select to access the picture enhancement menu
COLOR
BLC
VMD
Select submenu
ON, OFF,
Select submenu
OFF, SIL, OSD
Select submenu
Select to access the color control menu
• To enable Back Light Compensation (BLC) operation set to ON
• Select to access the BLC menu
• To enable Video Motion Detection (VMD) operation set to SIL (silent) or OSD (monitor alarm generates on-screen message)
• Select to access the VMD menu
MODE ID 10 character string Editable name for the selected mode
DEFAULTS Select submenu Return all settings for the selected mode to factory defaults
EXIT Exit the menu
ALC submenu
Function Selection
ALC LEVEL -15 - 0 - +15
SHUTGAIN Select submenu
Description
Adjusts the video output level
PEAK
AVERAGE
-15 - 0 - +15
Select to access the Shutter and Gain control menu
Adjust the balance between peak and average video control
ALC SPEED Slow, Medium, Fast Adjust the speed of the video level control loop.
EXIT Return to MODE menu
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 19
ALC --> Shutter/Gain submenu
Function
SHUTTER
Selection
AES, FL, FIXED
Description
• AES - auto-shutter - the camera automatically sets the optimum shutter speed for manual iris lenses
• FL - flickerless mode avoids interference from light sources (recommended for use with video iris or DC iris lenses only)
• FIXED - allows a user defined shutter speed
Only available if SHUTTER is AES. The camera tries to maintain the selected shutter speed as long as the light level of the scene permits.
DEFSHUT 1/60 (1/50), 1/100,
1/120, 1/250,
1/500, 1/1000,
1/2000, 1/5000,
1/10K
FIX SHUT 1/60 (1/50), 1/100,
1/120, 1/250,
1/500, 1/1000,
1/2000, 1/5000,
1/10K
SENSUP
GAIN
Only available if SHUTTER is FIXED. Selects shutter speed.
OFF, 2x, 3x, …,10x Selects the factor by which the sensitivity of the camera is increased.
AGC, FIXED • In AGC mode the camera automatically sets the gain to the lowest possible value needed to maintain a good picture
• In FIXED mode the gain is set at a predefined not scene dependent value
MAXGAIN 0, 1, ... 28
FIXGAIN
NIGHTSENSE
EXIT
0, 1, ... 28
OFF, FORCED,
AUTO
Available in AGC mode only. Selects the maximum value the gain can have during AGC operation.
Available in FIXED gain operation only. Selects the gain setting.
Nightsense™ extends the low-light performance of the camera.
• In AUTO mode, the camera automatically inches to monochrome in low-light conditions.
• In FORCED mode, the camera remains in highsensitivity monochrome operation.
Return to the ALC menu
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 20
Note
If SENS UP or NIGHTSENSE is active, some noise or spots may appear in the picture. This is normal camera behavior. SENS UP may cause some motion blur on moving objects.
If GAIN is set to FIXED, NIGHTSENSE will not become active.
If NIGHTSENSE is active, all color related menu items are disabled and cannot be accessed.
Enhance submenu
Function
AUTO
BLACK
Selection
ON, OFF
BLK LEVEL -50, ... 0, ...+50
CONTOUR -15 - 0 - +15
DNR
XF-DYN
EXIT
AUTO, OFF
OFF, LOW, MID,
HIGH
Description
Autoblack ON automatically increases the visibility of details
Adjusts the black level between 0 and approx
110mV. Zero position of slider corresponds to the factory default black level
Adjusts the sharpness of the picture. 0 corresponds to the default position.
In AUTO mode the camera automatically reduces the noise in picture. This may cause some motion blur on moving objects.
In XF-DYN mode the camera automatically optimizes the contrast in the picture.
Return to MODE menu
Color submenu
Function
WHITE
BALANCE
Selection
ATW, MANUAL,
AWB HOLD
Description
• ATW: Auto tracking white balance allows the camera to constantly adjust for optimal color reproduction.
• AWB HOLD: Puts the ATW on hold and saves the color settings.
• In MANUAL mode the Red, Green and Blue gain can be manually set to a desired position
WB SPEED Slow, Medium, Fast Adjust the speed of the white balance control loop.
RED gain -5 - 0 - +5 • ATW mode and AWB hold mode: adjusts the
Red gain to optimize the white point.
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 21
BLUE gain -5 - 0 - +5
RED
GREEN
BLUE
SAT
EXIT
-50 - 0 - +50
-15, … , 0 , … +5
• ATW mode and AWB hold mode: adjusts the B gain to optimize around the white point.
Controls all the colors individually for manual white balance only.
Adjusts the color saturation. -15 will lead to a monochrome image
Return to MODE menu
Back Light Compensation (BLC) submenu
Function
BLC
BLC LVL
AREA
EXIT
Selection
ON, OFF
-15,..0,..+15
Select submenu
Description
When ON, the video level is optimized for the selected area of the image. Parts outside this area may be underexposed or overexposed (this is normal).
BLC LEVEL adjust the balance between the selected BLC area and its surrounding.
Select to access the Back Light Compensation area menu (see selecting an area).
Return to MODE menu
Selecting an area
To set-up an area for BLC (or VMD), access the area menu by selecting the
AREA option from the BLC (or VMD) menu. Upon entering the AREA menu, the current area is displayed with the upper left corner flashing. The flashing corner of the image can be moved with the Up, Down, Left, Right arrow keys. Pressing the Select key moves the flashing cursor to the opposite corner, which can now be moved. Pressing Select again freezes the area and exits the area menu.
Video Motion Detection (VMD) submenu
Function
VMD
Selection
OFF, SIL, OSD
Description
When VMD is enabled and the camera can generate SIL (silent) or OSD (monitor alarm generates on-screen message) motion alarms.
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 22
AREA
ACTIVE
MOTION
SENS
EXIT
1, 2, 3, 4,
Select submenu
ON, OFF
Press SELECT to reset indicator
• It is possible to set 4 motion sensitive areas (per
MODE).
• Press SELECT to enter the area set-up menu.
Every area can be enabled individually by selecting YES.
Indicates the peak of measured motion in the selected area
Use the LEFT/RIGHT keys to set the SENSitivity for motion to the desired level. Motion above this level triggers alarm.
Return to MODE menu
Note
If VMD areas overlap, motion is only detected in the area with the lowest sequence number.
Defaults submenu
Selection Function
MODE
DEFAULTS
EXIT
Description
Select to restore the factory defaults. A confirmation screen appears. Allow 5 seconds for the camera to optimize the picture after a mode reset.
Return to MODE menu
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual
Installer Settings
EN | 23
Install menu
Function
LENS
WIZARD
Selection
Select submenu
I/O
SYNC
CAMERA ID Select submenu
DEFAULTS Select submenu
EXIT
Select submenu
Select submenu
Description
Select to optimize camera lens combination
Select to access the I/O functions
Select to access the synchronization functions
Select to access ID menu
Return all settings for all modes to factory defaults
Exit the menu
Install lens wizard submenu
Function Selection
LENS TYPE AUTO, MANUAL,
DCIRIS, VIDEO
DETECTED
SET BACK
FOCUS
NOW
SET LVL
EXIT
Description
In AUTO mode the camera auto detects the type of lens used or force the camera into a mode.
If the LENS TYPE detection is in AUTO, the detected lens type will be shown.
Select to force lens to its maximum opening. After focusing the lens the object of interest remains in focus in bright and low light conditions.
(Video iris lenses only). The level detector indicator must be set to the center by adjusting the level potentiometer on the lens, to obtain the best picture performance.
Return to the INSTALL menu
Adjustment procedure DC-iris Lens:
1.
Unlock the back focus locking button.
2.
Access the Lens Wizard menu.
3.
SET BACK FOCUS NOW is highlighted in the menu.
4.
Turn the back focus adjustment as required.
5.
Lock the back focus locking button.
6.
Exit the menu.
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 24
Adjustment procedure Manual-iris Lens:
1.
Unlock the back focus locking button.
2.
Adjust the lens to the maximum lens opening.
3.
Turn the back focus adjustment as required.
4.
Lock the back focus locking button.
Adjustment procedure Video-iris Lens:
1.
Unlock the back focus locking button.
2.
Access the Lens Wizard menu.
3.
SET BACK FOCUS NOW is highlighted in the menu.
4.
Turn the back focus adjustment as required.
5.
Lock the back focus locking button.
6.
Select SET LVL in the menu; the LEVEL bar appears.
7.
Point the camera at the scene it will be mostly viewing.
8.
Adjust the level potentiometer located on the lens until the
LEVEL bar is in the central position.
9.
Exit the menu.
Note
The best performance with video iris lenses is obtained when the peak/ average potentiometer of the lens is set to either full average or full peak matching the position of the peak/average balance in the MODE x ALC menu.
Install I/O submenu
Function
SYNC IN
Selection
75 Ohm, HIGH
COMM
CABLE
COMP
ON, OFF
OFF, DEFAULT,
RG59, COAX12,
COAX6
0, 1, .. +15
Description
Select 75 Ohm if the external sync input is not terminated elsewhere.
If OFF, Bilinx communication is disabled.
Cable compensation is used to avoid the need for amplifiers in long distance coax connections up to
1000m (3000ft). For optimum results select the coaxial cable type used or if unknown, DEFAULT.
Sets the level of cable compensation.
COMP
LEVEL
ALARM
EXIT
Select submenu
Return to the INSTALL menu
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 25
Install I/O --> Alarm submenu
Function
ACTIVE
ACTION
ALARM
OUT
EXIT
Selection
NONE, MODE1,
MODE2, MODE3
VMD, REMOTE
Description
NONE, HIGH, LOW Selects active_HIGH or active_LOW for the alarm input connector. Select NONE to disable alarm switching.
Selects the operating mode of the camera upon switching the alarm input.
Select VMD to close the output relay upon VMD alarms. Select REMOTE to make the output relay available to remote communication devices.
Return to the I/O menu
Install sync submenu
Function
SYNC
Selection
INTERNAL, LINE
LOCK, HV LOCK,
GENLOCK
Description
Select INTERNAL for free running camera operation, select LINE LOCK to lock to the power supply frequency, select HV LOCK to lock to the signal supplied to the external sync input, select
GENLOCK to lock the subcarrier as well.
Shows the actual sync mode used by the camera.
DETECTED
SYNC
VPHASE
HPHASE
SUB
PHASE
EXIT
0, 2, … 358 Adjusts the vertical phase offset (when in LINE
LOCK mode and a valid power supply frequency is detected).
-25, …, 0, … +125 Adjust the horizontal phase offset (when in EXT lock mode and a valid input signal is detected)
0, 2, … 358 Adjusts the sub-carrier phase offset (when in EXT
LOCK mode and a valid sub-carrier is detected).
Return to the INSTALL menu
Note
VPHASE, HPHASE and SUB-PHASE cannot be accessed if there is no valid locking signal.
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual
Install ID submenu
Function
CAMERA ID
Selection
ID POS OFF, TOP, BOT
EN | 26
Description
Enter a 16 character camera name string. Use
LEFT/RIGHT to change position in the string, use
UP/DOWN to select the character. Use SELECT to exit the string edit screen.
Select TOP to display the camera ID in the upper left corner; select BOT for the lower left corner.
The ID string is not displayed when the OSD menus are open.
Return to the INSTALL menu EXIT
Defaults submenu
Selection Function
ALL
DEFAULTS
EXIT
Description
Select to restore the factory defaults. A confirmation screen appears. Allow 5 seconds for the camera to optimize the picture after a mode reset.
Return to MODE menu
Camera Control Communication
This camera is equipped with a coaxial communications transceiver. In combination with VP-CFGSFT, the camera can be adjusted from the headend side of the coaxial cable. All menus can be accessed remotely giving full control of the camera. With this communication it is also possible to disable the local keys on the camera.
To avoid loss of communication on an installed camera, the
COMMUNICATION ON/OFF selection is NOT available while using remote control. This function can only be accessed with the camera buttons.
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual
Technical specification
1/2" CCD versions
Type number
Standard
Active pixels
Rated supply voltage
LTC
0610/11
PAL
752x582
LTC
0610/21
NTSC
768x492
24 VAC or 12 VDC
12-28 VAC (50/60 Hz)
12-36 VDC
Min illumination 0.18 lx
0.08 lx with NightSense
EN | 27
LTC
0610/51
PAL
752x582
LTC
0610/61
NTSC
768x492
230 VAC 50Hz, (/50)
110 VAC 60Hz, (/60)
Range: 100-2
30 VAC ±10%
50/60Hz
1/3" CCD versions
Type number
Standard
Active pixels
Rated supply voltage
LTC
0485/11
PAL
752x582
LTC
0485/21
NTSC
768x492
24 VAC or 12 VDC
12-28 VAC (50/60 Hz)
12-36 VDC
Min illumination < 0.24 lux
< 0.1 lux (with Nightsense)
LTC
0485/51
PAL
752x582
LTC
0485/61
NTSC
768x492
230 VAC 50Hz, (/50)
110 VAC 60Hz, (/60)
Range: 100-2
30 VAC ±10%
50/60Hz
All versions
Imager
Resolution
SNR
Video output
Y/C output
Interline CCD
540 TVL
> 50 dB
1 Vpp, 75 Ohm
Y: 1 Vpp
C: 0.3 Vpp
Synchronization Internal or HV-lock or Genlock or Line Lock selectable
Shutter AES (1/60 (1/50) to 1/100000), Flickerless, Fixed selectable
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 28
All versions
NightSense
Sens Up
Auto black
AGC
XF-DYN
DNR
Contour
BLC
Automatic dynamic range enhancement level selectable
Automatic noise filtering ON/OFF selectable
Sharpness enhancement level selectable
BLC On or Off selectable, with programmable area
White balance Automatic 2500 - 9000K (with AWB hold mode and manual mode)
Color saturation Adjustable from monochrome (0%) to 133% color
Lens Mount
ALC lens
Power consumption
C and CS compatible
Video or DC iris auto detect
< 5 W
Dimensions
Weight
Tripod Mount
Operating temperature
Controls
On, Off, Auto
Adjustable from OFF to 10x
On, Off selectable
AGC on or off (0 dB) selectable.
Maximum level selectable upto 28 dB
58 x 66 x 122 mm (HxWxL) without lens
450g without lens
Bottom (isolated) and Top ¼" 20 UNC
-20° to 50° C
OSD with softkey operation
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual
Accessories
Power transformers
• TC1334
• TC120PS
120VAC, 60Hz
120VAC, 60Hz
- 24VAC, 30VA
- 15VDC, 9VA
• TC220PSX-24 220-240VAC, 50/60Hz - 24VAC, 30VA
• TC220PS 220-240VAC, 50/60Hz - 15VDC, 9VA
EN | 29
Interface box:
• VP-CFGSFT Bilinx™ communication interface box and software
Recommended lenses
Varifocal lenses:
• LTC 3264/30
• LTC 3274/40
• LTC 3364/21
• LTC 3364/31
• LTC 3364/40
• LTC 3374/20
Zoom lenses:
• LTC 3283/20
• LTC 3384/21
1/2" DC-iris, 4.5-10mm F1.6-360
1/2" DC-iris, 7.5-75mm F2.2-360
1/3" DC-iris, 2.8-6mm F1.4-300 - IR
1/3" DC-iris, 3.5-8mm F1.4-300 - IR
1/3" DC-iris, 2.8-12mm F1.4-360
1/3" DC-iris, 5-50mm F1.4-185
1/2" Video iris, 8-48mm F1.4-360
1/3" DC-iris, 6-60mm F1.4-360
Bosch Security Systems | 2003-10 | V0.5
Dinion XF | Installation Manual EN | 30
Bosch Security Systems | 2003-10 | V0.5
Bosch Sicherheitssysteme GmbH
Ludwig-Bölkow-Allee
85521 Ottobrunn
Germany www.bosch-sicherheitssysteme.de
© 2003 Bosch Security Systems B.V.
Subject to change. Printed in Portugal.
3122 165 23051
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven
The Netherlands www.boschsecuritysystems.com
advertisement
Key Features
- 15-bit digital signal processing
- Three pre-programmed operation modes
- True color reproduction
- Adaptive dynamic range optimization
- Bilinx bi-directional coaxial communications