Bosch LTC 0610, LTC 0485 security camera Installation Instructions

Bosch LTC 0610, LTC 0485 security camera Installation Instructions

The Bosch LTC-0485-21 is a high-performance 1/3-inch CCD camera with 15-bit digital signal processing for outstanding picture performance in all lighting conditions. It features three pre-programmed operation modes, noise elimination, true color reproduction, adaptive dynamic range optimization, Bilinx™ bi-directional coaxial communications, genlock including sub-carrier locking, and enhanced video motion detection.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Bosch LTC 0610 & LTC 0485 series security cameras Installation Instructions | Manualzz

DinionXFFrontPage.fm Page 1 Friday, January 21, 2005 4:13 PM

Dinion

XF

– LTC 0610 & LTC 0485 series cameras

EN

Installation Instructions

15-bit digital color camera

FR

Manuel d’installation

Caméra numérique couleur

15 bits

DE

Installationshandbuch

15-Bit digitale Farbkamera

ES

Manual de instalación

Cámara digital en color de

15 bits

NL

Installatiehandleiding

15-bits digitale kleurencamera

IT

Manuale di installazione

Telecamera digitale a colori

15 bit

PT

ZH

Manual de Instalação

Câmara digital policromática de 15 bits

安装说明

15 位数码彩色摄像机

Dinion XF | Installation Manual

SAFETY PRECAUTIONS

EN | 3

Danger

The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product's enclosure that may be of sufficient magnitude to constitute a risk to persons.

Warning

The exclamation mark within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

Caution

To reduce the risk of electric shock, do not remove cover (or back). No user-serviceable parts inside. Refer servicing to qualified service personnel.

Important Safeguards

1. Read these instructions.

2. Keep these instructions.

3. Comply with all warnings.

4. Follow all instructions.

5. Do not use this equipment near water.

6. Clean only with dry cloth.

7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8. Do not install near any heat sources such as radiators, heat registers, stoves, or other equipment (including amplifiers) that produce heat.

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 4

9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. Both the wide blade and the third prong are provided for your safety. If the supplied plug does not fit into your outlet, consult an electrician for advice.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the equipment.

11. Only use attachments/accessories specified by the manufacturer.

12. Unplug this equipment during lightning storms or when unused for long periods of time.

13. Refer all servicing to qualified service personnel. Servicing is required when the equipment has been damaged in any way, such as when power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the equipment, the equipment has been exposed to rain or moisture, does not operate normally, or has been dropped.

14. An all-pole mains switch with a contact separation of at least 3mm in each pole shall be incorporated in the electrical installation of the building.

Warning

To reduce the risk of fire or electric shock, this apparatus should not be exposed to rain or moisture and objects filled with liquids, such as vases, should not be placed on this apparatus.

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 5

FCC Information

This equipment has been tested and found to comply with the limits for a

Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a

• particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/ TV technician for help.

Note

Any change or modification of the equipment, not expressly approved by

Bosch authorization, could void the user's authority to operate the equipment. For additional information or to speak to a representative, please contact the Bosch Security Systems location nearest to you or visit our web site at www.boschsecuritysystems.com

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 6

Introduction

The Dinion XF is a high-performance smart surveillance color camera. It incorporates 15-bit digital signal processing for outstanding picture performance under all lighting conditions. The Dinion XF is easy to install and ready to use, and offers the best solution for demanding scene conditions. Features include:

• Three pre-programmed operation modes

• Noise elimination, true color reproduction

• Adaptive dynamic range optimization

• Bilinx™ bi-directional coaxial communications

• Genlock including sub-carrier locking

• Enhanced video motion detection

Type number overview

Type number

Standard

Supply voltage

CCD type

LTC

0610/11

LTC

0610/21

PAL NTSC

24 VAC or 12 VDC

PAL NTSC

230 VAC 50Hz 110 VAC 60Hz

1/2"

LTC

0610/51

LTC

0610/61

Type number

Standard

Supply voltage

CCD type

LTC

0485/11

LTC

0485/21

PAL NTSC

24 VAC or 12 VDC

PAL NTSC

230 VAC 50Hz 110 VAC 60Hz

1/3"

LTC

0485/51

LTC

0485/61

Caution

Ensure that your power supply matches the rated voltage of your camera before installing.

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 7

Unpacking

Unpack carefully and handle the equipment with care. The packaging contains:

• Dinion XF camera

• CCD protection cap

• Spare lens connector (male)

• These instructions

Note

If equipment appears to have been damaged during shipment, repack it in the original packaging and notify the shipping agent or supplier.

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual

Connections

Power

Low voltage versions

10mm

VIDEO

DC 12V

AC 24V

SVHS

SYNC

ALARM

High voltage versions

VIDEO

SVHS

SYNC

ALARM

EN | 8

For low voltage cameras:

• push in the tabs to open the quick-connectors (these connections are not polarity sensitive).

• use AWG16 to 22 stranded wire or AWG16 to 26 solid wire; cut back

10mm (0.4") of insulation.

Composite video

VIDEO

DC 12V

AC 24V

SVHS

SYNC

ALARM

VIDEO

SVHS

SYNC

ALARM

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual

Sync

VIDEO

DC 12V

AC 24V

SVHS

SYNC

ALARM

Y/C

VIDEO

DC 12V

AC 24V

SVHS

SYNC

ALARM

Pin

3

4

1

2

Y/C socket

GND Y

GND C

Y

C

3

1

4

2

VIDEO

SVHS

SYNC

ALARM

VIDEO

SVHS

SYNC

ALARM

EN | 9

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 10

Alarm connector

Pin Alarm socket

Alarm

3

4

1

2

Ground

Alarm in

Relay out contact 1

Relay out contact 2

Pin 1 Pin 4

• Max. wire diameter AWG 22-28 for both stranded and solid

• Default relay position n.o. (normally open), no alarm

• Alarm output relay switching capability: Max voltage 30VAC or

+40VDC. Max 0.5 A continuous, 10VA.

• Alarm in: TTL logic, +5V nominal, +40VDC max, DC coupled with

22k

Ω pull-up to +3.3V

• Alarm in: configurable as active low or active high

• Max. 42V allowed between camera ground and each of the relay pins.

Lens mounting

The camera accepts both C and CS-mount lenses. DC-iris lenses are recommended for the best picture performance. The camera automatically detects the type of lens used and optimizes performance accordingly.

A spare male lens connector is provided.

Caution

To avoid damaging the CCD sensor when using a C-mount lens, turn the red back focus ring counterclockwise until it stops (see back focus adjustment) before mounting the lens.

Lenses weighing more than 0.5 kg (1.1lbs) must be separately supported.

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 11

Bosch

Bosch

Pin

3

4

1

2

Video iris lens

Supply (11.5V ±0.5, 50mA max.)

Not used

Video signal 1Vpp 1kOhm

Ground

DC iris lens

Damp -

Damp +

Drive +

Drive -

Note

If a short circuit is detected on the lens connector, the on-screen display

(OSD) failure message LENS SHORT CIRCUIT is shown. The lens circuit is automatically disabled to avoid internal damage. Remove the lens connector and check the pin connections.

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 12

Back focus adjustment

To optimize picture sharpness in both bright and low-level lighting, adjust the back focus. Use the camera's unique Lens Wizard (see Advanced Setup). This ensures that the object of interest always remains in focus even when focusing at the maximum lens opening.

When back focusing vari-focus lenses, adjust to obtain a sharp picture in both wide-angle and tele positions for both far and near focus.

When back focusing zoom lenses, ensure the object of interest remains in focus throughout the entire zoom range of the lens.

To adjust back focus:

1.

Open the slide door at the side of the camera

2.

Unlock the back focus locking button.

Bosch

Bosch

3.

Turn the back focus adjustment as required.

Bosch

4.

Lock the back focus locking button.

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 13

M ounting the camera

The camera can be mounted from the top or bottom. The bottom mounting is isolated from ground. With outdoor scenes, a DC-iris lens is recommended.

Caution

Do not point the camera/lens into direct sunlight.

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 14

Advanced Set-up

The Dinion XF normally provides an optimal picture without the need for further adjustments. However, advanced set-up options are available for getting the best results from the camera under special circumstances. There are two main menus; a Mode menu and an Installer menu.

The camera has three pre-programmed operating modes that can be selected in the Mode menu. These modes are pre-programmed by default but you can adjust them according to your preferences. The Mode menu allows you to select and set-up the picture enhancement functions for each mode. If you are not happy with your changes, you can always recall the default values for the mode.

The camera also has an Installer menu in which the installation settings can be set.

The Mode and Installer menus have functions that can be selected directly or submenus for more detailed set-up.

Accessing and navigating menus

Five keys, located behind the side panel, are used for navigating through the various menus.

To access the set-up menus, press the menu/select key (center).

Bosch

Bosch

The main menu appears on the OSD. Use the arrow keys for navigation.

When the Bilinx™ communications link is active, the buttons on the camera are disabled. You can also set up Bilinx™ so that the camera buttons remain disabled even when Bilinx™ is not actively controlling the camera. This prevents unauthorized change of the camera settings.

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual

Menu Structure

MODE

ALC

ENHANCE

COLOR

BLC

VMD

MODE ID

DEFAULTS

MODE x ALC

ALC LEVEL

SHUT/GAIN

PEAK / AVERAGE

ALC SPEED

MODE X ENHANCE

AUTO BLACK

BLACK LEVEL

CONTOUR

DNR

XF-DYNAMIC

MODE X COLOR

WHITE BALANCE

WBSPEED

R GAIN

G-GAIN

B-GAIN

SATURATION

MODE X BLC

BLC

BLC LEVEL

BLC AREA

MODE X VMD

VMD

AREA

ACTIVE

MOTION

SENSITIVITY

MODE X DEFAULTS

CONFIRM

Bosch Security Systems | 2003-10 | V0.5

EN | 15

MODE x SHUTGAIN

SHUTTER

DEFSHUT

SENS UP

GAIN

MAX GAIN

NIGHTSENSE

Dinion XF | Installation Manual

INSTALL

LENS WIZARD

I/O

SYNC

CAMERA ID

DEFAULTS

INSTALL LENS WIZARD

LENS TYPE

DETECTED

SET BACK FOCUS

SET LEVEL

INSTALL I/O

SYNC INPUT

COMMUNICATION

CABLE COMP

COMP LEVEL

ALARM

INSTALL SYNC

SYNC

DETECTED SYNC

V PHASE

H PHASE

SUB PHASE

INSTALL CAMERA ID

CAMERA ID

ID POSITION

MAC ADDRESS

EN | 16

INSTALL I/O ALARM

ALARM IN

ACTIVE

ACTION

ALARM OUT

ALL DEFAULTS

CONFIRM

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual

Hints for menu navigation

How to use the 5 keys

Up key

EN | 17

Menu/select key

Left key Right key

Lock

Down key

• Press the menu/select key to access the menus or to move to the next or previous menu.

• Press the menu/select key for approximately 1.5 seconds to open the

Installer menu.

• Use the up or down keys to scroll up or down through a menu.

• Use the left or right keys to move through options or to set parameters.

• When in a menu, quickly pressing the menu/select key twice restores the selected item to its factory default.

• To close all menus at once from any menu, select the Exit item and hold down the menu/select key until the menu display disappears.

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 18

Mode menu

Function Selection

MODE

ALC

1, 2, 3

Select submenu

ENHANCE Select submenu

Description

Select operating mode

Select to access the video level control menu

Select to access the picture enhancement menu

COLOR

BLC

VMD

Select submenu

ON, OFF,

Select submenu

OFF, SIL, OSD

Select submenu

Select to access the color control menu

• To enable Back Light Compensation (BLC) operation set to ON

• Select to access the BLC menu

• To enable Video Motion Detection (VMD) operation set to SIL (silent) or OSD (monitor alarm generates on-screen message)

• Select to access the VMD menu

MODE ID 10 character string Editable name for the selected mode

DEFAULTS Select submenu Return all settings for the selected mode to factory defaults

EXIT Exit the menu

ALC submenu

Function Selection

ALC LEVEL -15 - 0 - +15

SHUTGAIN Select submenu

Description

Adjusts the video output level

PEAK

AVERAGE

-15 - 0 - +15

Select to access the Shutter and Gain control menu

Adjust the balance between peak and average video control

ALC SPEED Slow, Medium, Fast Adjust the speed of the video level control loop.

EXIT Return to MODE menu

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 19

ALC --> Shutter/Gain submenu

Function

SHUTTER

Selection

AES, FL, FIXED

Description

• AES - auto-shutter - the camera automatically sets the optimum shutter speed for manual iris lenses

• FL - flickerless mode avoids interference from light sources (recommended for use with video iris or DC iris lenses only)

• FIXED - allows a user defined shutter speed

Only available if SHUTTER is AES. The camera tries to maintain the selected shutter speed as long as the light level of the scene permits.

DEFSHUT 1/60 (1/50), 1/100,

1/120, 1/250,

1/500, 1/1000,

1/2000, 1/5000,

1/10K

FIX SHUT 1/60 (1/50), 1/100,

1/120, 1/250,

1/500, 1/1000,

1/2000, 1/5000,

1/10K

SENSUP

GAIN

Only available if SHUTTER is FIXED. Selects shutter speed.

OFF, 2x, 3x, …,10x Selects the factor by which the sensitivity of the camera is increased.

AGC, FIXED • In AGC mode the camera automatically sets the gain to the lowest possible value needed to maintain a good picture

• In FIXED mode the gain is set at a predefined not scene dependent value

MAXGAIN 0, 1, ... 28

FIXGAIN

NIGHTSENSE

EXIT

0, 1, ... 28

OFF, FORCED,

AUTO

Available in AGC mode only. Selects the maximum value the gain can have during AGC operation.

Available in FIXED gain operation only. Selects the gain setting.

Nightsense™ extends the low-light performance of the camera.

• In AUTO mode, the camera automatically inches to monochrome in low-light conditions.

• In FORCED mode, the camera remains in highsensitivity monochrome operation.

Return to the ALC menu

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 20

Note

If SENS UP or NIGHTSENSE is active, some noise or spots may appear in the picture. This is normal camera behavior. SENS UP may cause some motion blur on moving objects.

If GAIN is set to FIXED, NIGHTSENSE will not become active.

If NIGHTSENSE is active, all color related menu items are disabled and cannot be accessed.

Enhance submenu

Function

AUTO

BLACK

Selection

ON, OFF

BLK LEVEL -50, ... 0, ...+50

CONTOUR -15 - 0 - +15

DNR

XF-DYN

EXIT

AUTO, OFF

OFF, LOW, MID,

HIGH

Description

Autoblack ON automatically increases the visibility of details

Adjusts the black level between 0 and approx

110mV. Zero position of slider corresponds to the factory default black level

Adjusts the sharpness of the picture. 0 corresponds to the default position.

In AUTO mode the camera automatically reduces the noise in picture. This may cause some motion blur on moving objects.

In XF-DYN mode the camera automatically optimizes the contrast in the picture.

Return to MODE menu

Color submenu

Function

WHITE

BALANCE

Selection

ATW, MANUAL,

AWB HOLD

Description

• ATW: Auto tracking white balance allows the camera to constantly adjust for optimal color reproduction.

• AWB HOLD: Puts the ATW on hold and saves the color settings.

• In MANUAL mode the Red, Green and Blue gain can be manually set to a desired position

WB SPEED Slow, Medium, Fast Adjust the speed of the white balance control loop.

RED gain -5 - 0 - +5 • ATW mode and AWB hold mode: adjusts the

Red gain to optimize the white point.

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 21

BLUE gain -5 - 0 - +5

RED

GREEN

BLUE

SAT

EXIT

-50 - 0 - +50

-15, … , 0 , … +5

• ATW mode and AWB hold mode: adjusts the B gain to optimize around the white point.

Controls all the colors individually for manual white balance only.

Adjusts the color saturation. -15 will lead to a monochrome image

Return to MODE menu

Back Light Compensation (BLC) submenu

Function

BLC

BLC LVL

AREA

EXIT

Selection

ON, OFF

-15,..0,..+15

Select submenu

Description

When ON, the video level is optimized for the selected area of the image. Parts outside this area may be underexposed or overexposed (this is normal).

BLC LEVEL adjust the balance between the selected BLC area and its surrounding.

Select to access the Back Light Compensation area menu (see selecting an area).

Return to MODE menu

Selecting an area

To set-up an area for BLC (or VMD), access the area menu by selecting the

AREA option from the BLC (or VMD) menu. Upon entering the AREA menu, the current area is displayed with the upper left corner flashing. The flashing corner of the image can be moved with the Up, Down, Left, Right arrow keys. Pressing the Select key moves the flashing cursor to the opposite corner, which can now be moved. Pressing Select again freezes the area and exits the area menu.

Video Motion Detection (VMD) submenu

Function

VMD

Selection

OFF, SIL, OSD

Description

When VMD is enabled and the camera can generate SIL (silent) or OSD (monitor alarm generates on-screen message) motion alarms.

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 22

AREA

ACTIVE

MOTION

SENS

EXIT

1, 2, 3, 4,

Select submenu

ON, OFF

Press SELECT to reset indicator

• It is possible to set 4 motion sensitive areas (per

MODE).

• Press SELECT to enter the area set-up menu.

Every area can be enabled individually by selecting YES.

Indicates the peak of measured motion in the selected area

Use the LEFT/RIGHT keys to set the SENSitivity for motion to the desired level. Motion above this level triggers alarm.

Return to MODE menu

Note

If VMD areas overlap, motion is only detected in the area with the lowest sequence number.

Defaults submenu

Selection Function

MODE

DEFAULTS

EXIT

Description

Select to restore the factory defaults. A confirmation screen appears. Allow 5 seconds for the camera to optimize the picture after a mode reset.

Return to MODE menu

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual

Installer Settings

EN | 23

Install menu

Function

LENS

WIZARD

Selection

Select submenu

I/O

SYNC

CAMERA ID Select submenu

DEFAULTS Select submenu

EXIT

Select submenu

Select submenu

Description

Select to optimize camera lens combination

Select to access the I/O functions

Select to access the synchronization functions

Select to access ID menu

Return all settings for all modes to factory defaults

Exit the menu

Install lens wizard submenu

Function Selection

LENS TYPE AUTO, MANUAL,

DCIRIS, VIDEO

DETECTED

SET BACK

FOCUS

NOW

SET LVL

EXIT

Description

In AUTO mode the camera auto detects the type of lens used or force the camera into a mode.

If the LENS TYPE detection is in AUTO, the detected lens type will be shown.

Select to force lens to its maximum opening. After focusing the lens the object of interest remains in focus in bright and low light conditions.

(Video iris lenses only). The level detector indicator must be set to the center by adjusting the level potentiometer on the lens, to obtain the best picture performance.

Return to the INSTALL menu

Adjustment procedure DC-iris Lens:

1.

Unlock the back focus locking button.

2.

Access the Lens Wizard menu.

3.

SET BACK FOCUS NOW is highlighted in the menu.

4.

Turn the back focus adjustment as required.

5.

Lock the back focus locking button.

6.

Exit the menu.

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 24

Adjustment procedure Manual-iris Lens:

1.

Unlock the back focus locking button.

2.

Adjust the lens to the maximum lens opening.

3.

Turn the back focus adjustment as required.

4.

Lock the back focus locking button.

Adjustment procedure Video-iris Lens:

1.

Unlock the back focus locking button.

2.

Access the Lens Wizard menu.

3.

SET BACK FOCUS NOW is highlighted in the menu.

4.

Turn the back focus adjustment as required.

5.

Lock the back focus locking button.

6.

Select SET LVL in the menu; the LEVEL bar appears.

7.

Point the camera at the scene it will be mostly viewing.

8.

Adjust the level potentiometer located on the lens until the

LEVEL bar is in the central position.

9.

Exit the menu.

Note

The best performance with video iris lenses is obtained when the peak/ average potentiometer of the lens is set to either full average or full peak matching the position of the peak/average balance in the MODE x ALC menu.

Install I/O submenu

Function

SYNC IN

Selection

75 Ohm, HIGH

COMM

CABLE

COMP

ON, OFF

OFF, DEFAULT,

RG59, COAX12,

COAX6

0, 1, .. +15

Description

Select 75 Ohm if the external sync input is not terminated elsewhere.

If OFF, Bilinx communication is disabled.

Cable compensation is used to avoid the need for amplifiers in long distance coax connections up to

1000m (3000ft). For optimum results select the coaxial cable type used or if unknown, DEFAULT.

Sets the level of cable compensation.

COMP

LEVEL

ALARM

EXIT

Select submenu

Return to the INSTALL menu

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 25

Install I/O --> Alarm submenu

Function

ACTIVE

ACTION

ALARM

OUT

EXIT

Selection

NONE, MODE1,

MODE2, MODE3

VMD, REMOTE

Description

NONE, HIGH, LOW Selects active_HIGH or active_LOW for the alarm input connector. Select NONE to disable alarm switching.

Selects the operating mode of the camera upon switching the alarm input.

Select VMD to close the output relay upon VMD alarms. Select REMOTE to make the output relay available to remote communication devices.

Return to the I/O menu

Install sync submenu

Function

SYNC

Selection

INTERNAL, LINE

LOCK, HV LOCK,

GENLOCK

Description

Select INTERNAL for free running camera operation, select LINE LOCK to lock to the power supply frequency, select HV LOCK to lock to the signal supplied to the external sync input, select

GENLOCK to lock the subcarrier as well.

Shows the actual sync mode used by the camera.

DETECTED

SYNC

VPHASE

HPHASE

SUB

PHASE

EXIT

0, 2, … 358 Adjusts the vertical phase offset (when in LINE

LOCK mode and a valid power supply frequency is detected).

-25, …, 0, … +125 Adjust the horizontal phase offset (when in EXT lock mode and a valid input signal is detected)

0, 2, … 358 Adjusts the sub-carrier phase offset (when in EXT

LOCK mode and a valid sub-carrier is detected).

Return to the INSTALL menu

Note

VPHASE, HPHASE and SUB-PHASE cannot be accessed if there is no valid locking signal.

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual

Install ID submenu

Function

CAMERA ID

Selection

ID POS OFF, TOP, BOT

EN | 26

Description

Enter a 16 character camera name string. Use

LEFT/RIGHT to change position in the string, use

UP/DOWN to select the character. Use SELECT to exit the string edit screen.

Select TOP to display the camera ID in the upper left corner; select BOT for the lower left corner.

The ID string is not displayed when the OSD menus are open.

Return to the INSTALL menu EXIT

Defaults submenu

Selection Function

ALL

DEFAULTS

EXIT

Description

Select to restore the factory defaults. A confirmation screen appears. Allow 5 seconds for the camera to optimize the picture after a mode reset.

Return to MODE menu

Camera Control Communication

This camera is equipped with a coaxial communications transceiver. In combination with VP-CFGSFT, the camera can be adjusted from the headend side of the coaxial cable. All menus can be accessed remotely giving full control of the camera. With this communication it is also possible to disable the local keys on the camera.

To avoid loss of communication on an installed camera, the

COMMUNICATION ON/OFF selection is NOT available while using remote control. This function can only be accessed with the camera buttons.

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual

Technical specification

1/2" CCD versions

Type number

Standard

Active pixels

Rated supply voltage

LTC

0610/11

PAL

752x582

LTC

0610/21

NTSC

768x492

24 VAC or 12 VDC

12-28 VAC (50/60 Hz)

12-36 VDC

Min illumination 0.18 lx

0.08 lx with NightSense

EN | 27

LTC

0610/51

PAL

752x582

LTC

0610/61

NTSC

768x492

230 VAC 50Hz, (/50)

110 VAC 60Hz, (/60)

Range: 100-2

30 VAC ±10%

50/60Hz

1/3" CCD versions

Type number

Standard

Active pixels

Rated supply voltage

LTC

0485/11

PAL

752x582

LTC

0485/21

NTSC

768x492

24 VAC or 12 VDC

12-28 VAC (50/60 Hz)

12-36 VDC

Min illumination < 0.24 lux

< 0.1 lux (with Nightsense)

LTC

0485/51

PAL

752x582

LTC

0485/61

NTSC

768x492

230 VAC 50Hz, (/50)

110 VAC 60Hz, (/60)

Range: 100-2

30 VAC ±10%

50/60Hz

All versions

Imager

Resolution

SNR

Video output

Y/C output

Interline CCD

540 TVL

> 50 dB

1 Vpp, 75 Ohm

Y: 1 Vpp

C: 0.3 Vpp

Synchronization Internal or HV-lock or Genlock or Line Lock selectable

Shutter AES (1/60 (1/50) to 1/100000), Flickerless, Fixed selectable

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 28

All versions

NightSense

Sens Up

Auto black

AGC

XF-DYN

DNR

Contour

BLC

Automatic dynamic range enhancement level selectable

Automatic noise filtering ON/OFF selectable

Sharpness enhancement level selectable

BLC On or Off selectable, with programmable area

White balance Automatic 2500 - 9000K (with AWB hold mode and manual mode)

Color saturation Adjustable from monochrome (0%) to 133% color

Lens Mount

ALC lens

Power consumption

C and CS compatible

Video or DC iris auto detect

< 5 W

Dimensions

Weight

Tripod Mount

Operating temperature

Controls

On, Off, Auto

Adjustable from OFF to 10x

On, Off selectable

AGC on or off (0 dB) selectable.

Maximum level selectable upto 28 dB

58 x 66 x 122 mm (HxWxL) without lens

450g without lens

Bottom (isolated) and Top ¼" 20 UNC

-20° to 50° C

OSD with softkey operation

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual

Accessories

Power transformers

• TC1334

• TC120PS

120VAC, 60Hz

120VAC, 60Hz

- 24VAC, 30VA

- 15VDC, 9VA

• TC220PSX-24 220-240VAC, 50/60Hz - 24VAC, 30VA

• TC220PS 220-240VAC, 50/60Hz - 15VDC, 9VA

EN | 29

Interface box:

• VP-CFGSFT Bilinx™ communication interface box and software

Recommended lenses

Varifocal lenses:

• LTC 3264/30

• LTC 3274/40

• LTC 3364/21

• LTC 3364/31

• LTC 3364/40

• LTC 3374/20

Zoom lenses:

• LTC 3283/20

• LTC 3384/21

1/2" DC-iris, 4.5-10mm F1.6-360

1/2" DC-iris, 7.5-75mm F2.2-360

1/3" DC-iris, 2.8-6mm F1.4-300 - IR

1/3" DC-iris, 3.5-8mm F1.4-300 - IR

1/3" DC-iris, 2.8-12mm F1.4-360

1/3" DC-iris, 5-50mm F1.4-185

1/2" Video iris, 8-48mm F1.4-360

1/3" DC-iris, 6-60mm F1.4-360

Bosch Security Systems | 2003-10 | V0.5

Dinion XF | Installation Manual EN | 30

Bosch Security Systems | 2003-10 | V0.5

Bosch Sicherheitssysteme GmbH

Ludwig-Bölkow-Allee

85521 Ottobrunn

Germany www.bosch-sicherheitssysteme.de

© 2003 Bosch Security Systems B.V.

Subject to change. Printed in Portugal.

3122 165 23051

Bosch Security Systems B.V.

P.O. Box 80002

5600 JB Eindhoven

The Netherlands www.boschsecuritysystems.com

advertisement

Key Features

  • 15-bit digital signal processing
  • Three pre-programmed operation modes
  • True color reproduction
  • Adaptive dynamic range optimization
  • Bilinx bi-directional coaxial communications

Frequently Answers and Questions

What are the different models in the LTC 0610 series?
The LTC 0610 series includes models for PAL and NTSC standards, with different power supply options (24 VAC or 12 VDC, or 230 VAC/110 VAC).
What are the different models in the LTC 0485 series?
Similar to the LTC 0610 series, the LTC 0485 series offers PAL and NTSC models with various power supply options (24 VAC or 12 VDC, or 230 VAC/110 VAC).
How do I adjust the back focus of the camera?
You can use the camera's Lens Wizard feature to adjust the back focus for optimal picture sharpness in both bright and low-level lighting. Follow the steps provided in the instruction manual.
What is the purpose of the Bilinx communication feature?
The Bilinx communication feature allows you to adjust the camera remotely from the headend side of the coaxial cable using a VP-CFGSFT interface box. You can access all menus and control the camera settings remotely. You can also disable the local keys on the camera to prevent unauthorized changes.
What are the minimum illumination levels for these cameras?
The LTC 0610 series cameras have a minimum illumination of 0.18 lx, while the LTC 0485 series cameras have a minimum illumination of < 0.24 lux. Both series offer low-light performance enhancement with the NightSense feature.

Related manuals

Download PDF

advertisement