Salamander_Brochure

Salamander_Brochure
Contents
01
Making water perform
02
Know H2Ow - shower pumps explained
04
Identifying your household plumbing system
06
Pump application chart
08
CT pumps
10
Right pumps
12
Right whole house pumps
14
ESP CPV pumps
18
NEW
CT Regenerative pumps
Pg. 08
Right Centrifugal pumps
Pg. 10
Force pumps
22
PumpWise - An initiative to help customers
23
Warranty
24
Customer service
25
General specification
26
Typical shower pump applications schematic drawings
28
S flange - Hot water connection & supply
29
Hot water supply blending valve
29
Anti-Vibration couplers
Making water perform
ESP CPV Centrifugal pumps
Pg. 14
NEW
Salamander FORCE
Brass regenerative pumps
Pg. 18
Quality
Achievement of ISO9000 compliance reflects our
commitment to deliver high quality in all facets of our
business. All of our pumps are tested to ensure they are leak
free and in full working order before leaving the factory.
Technology
Choose a Salamander pump
and enjoy stimulating
power from your shower. Our
comprehensive range of
pumps brings you the latest
technology and an
assurance of quality and
reliability – all at exceptional
value for money.
Salamander pumps are
manufactured in the UK from
top quality components, the
majority of which are
sourced from the EU.
Each component is
extensively tested for long
life and every pump is subject
to strict quality controls
before it leaves our factory
in Sunderland.
Our sophisticated use
of technology, which
incorporates micro
electronics and sensors in
the ESP range, delivers
unrivalled performance that
retains pressure even under
high flow rate conditions.
All pumps come with
installation guidelines and
access to our free technical
helpline.
When installed in accordance
with those guidelines we are
confident that you will enjoy
trouble free ownership of
your Salamander pump for
many years to come.
We have pioneered the use of centrifugal technology to
deliver some of the quietest and most flow efficient shower
pumps in the market. Technology is particularly evident in the
innovative ESP range. It utilises electronic sensors to activate
and protect the pump whatever the consumer’s household
plumbing situation is, enabling the shower pump to identify
whether the consumer has a positive or negative
head situation.
Service
With over 70 years of plumbing experience on our technical
advice lines and a team that is highly responsive to all
customer service needs, our service provision is second
to none.
Value
Our competitive pricing has helped drive our accelerated
sales growth over the last decade to get Salamander to its
position as one of the leading shower pump manufacturers in
the UK today. We believe our pumps deliver outstanding value
for money.
Salamander Pumps
Salamander Pumps
01
Know H2Ow
Shower pumps explained
Positive head system (Gravity-fed)
Usable capacity minimum
50 gallons per bathroom
and 30 gallons per en suite
Positive head systems (Gravity-fed)
Several different plumbing systems are used in UK
homes, the most common of which is a gravity-fed
system detailed in the schematic diagram.
In these types of systems there is usually a cold
water cistern in the loft with a hot water tank
below it, probably in an airing cupboard. If your
shower is not forceful enough due to insufficient
water pressure, this can be easily boosted by the
installation of a pump.
Positive head
Vent
and other
services
The hot
connection
must be via
an approved
side or top
entry flange
The diagram shows where the pump should be
situated for gravity-fed systems.
MAX
65°C
Non return valve
Hot outlet ONLY
Outlets
C
H
Inlet
Negative head
When the distance
between the cold water
storage cistern and the
shower head is 600 mm
or less, or when the
natural flow is poor or
less than 2 litres per
minute of combined hot
and cold it is possible a
negative head pump may
be required.
Negative head systems (Gravity-fed)
Twin Impeller
Single Impeller
Negative head systems are where poor natural flow
of water goes to the shower head because it is above
the height of the base of the cold water tank or
there is limited height between the base of the cold
water tank and the shower head. Most instances of
negative head systems occur in loft conversions or
where the cold water tank sits on the joists in
the loft.
Twin impeller pumps pump both hot and cold water
supplies, one impeller on the cold inlet and one
impeller on the hot inlet.
Single impeller pumps simply take one inlet, and that
can be cold or hot water, or blended water after a
shower or mixing valve.
Each impeller on the pump then goes on to supply
the outlet, which is commonly a shower valve.
Typically single impeller pumps can be used to
supply single hot or cold taps, electric showers,
combination boilers and washing machines.
See page 14 for our range of negative head pumps.
Making water perform
02
Air vents, both
hot and cold
Electric showers and combination boilers need to be
fed via a header tank.
See pages 4 and 5 for where these pumps could be
used in a property.
Continuous Rating
Regenerative
Continuous rating determines how long the pump can run for before the motor
begins to overheat. For family showering, pumps can run for a long time, particularly
in the morning. All Salamander pumps with the exception of RSP, RHP, ESP CPV 140
are continuously rated.
Water is fed into the
side inlet where it is then
forced around anticlockwise by the blades
of the impeller and is
deflected through
the outlet.
Training
Whether you need merchant trade
counter training, showroom staff
training, or you are at college requiring
training, our dedicated training manager,
Malcolm Campbell, can come to you and
deliver training bespoke to your needs.
Call 0191 516 2002 for more information
on how this training might benefit you.
For installers check out Malcolm’s (AKA Big Malc)
blog at: http://askbigmalc.wordpress.com/about.
Centrifugal
Water is fed into the
centre of the rotating
impeller (shown in red).
Centrifugal action
causes the water to
flow radially, outwards
through impeller and
on to the fixed blades
(around the pump casing)
which deflect and force
the water through
the outlet.
Salamander Pumps
Salamander Pumps
03
Identify your household plumbing system
and where pumps can be used in the home
Baths and handbasins
Pumps can be used in a variety of locations in the home.
Generally they can be used to give enhanced shower
performance or simply to ensure household appliances or
washbasins/baths have continuity of supply and pressure.
Combination boilers
Where incoming mains cold pressure iis
insufficient to operate the combination boiler
effectively, a cold water ‘break’ tank can be
installed. A single impeller pump can be installed
with the supply from the header tank and then
into the combination boiler.
Dishwashers
Quite often, because
se of low water
pressure in the home a single impeller
pump can be used to supply the
dishwasher to ensure consistency of
supply and pressure.
Making water perform
04
Appliances in loft conversions - Negative head
Negative head generally occurs where no natural flow of water can
get to the shower head or outlet. Loft conversions are commonly
in negative head mode. A negative head pump needs to be used,
where the pump starts automatically when the outlet is opened.
The outlet can be a tap, shower or bath fill application.
Reducing air in
the system
Air is an enemy of all shower pumps and we
recommend the use of an ‘S’ type Salamander flange.
The flange is installed on top of the hot water
cylinder and reduces air ingress from the hot water
storage where, typically, air is prevalent.
Washing machines
Quite often, because of low
w water pressure in
n
the home, a twin impeller pump can be
b used
d
to supply the washing machine to ensure
consistency of supply and pressure.
Taps and basins
Where water pressure is
i low
l in
i a property,
t th
the
restriction from hot and cold water taps can mean
that no flow is forthcoming. The fitting of whole
house pumps can be used to boost the supply of hot
and cold water to taps and basins.
If in doubt as to which Pump to use please call
on 0191 516 2002
Salamander Pumps
Salamander Pumps
05
Find the right pump for your application
1
2
To a combi boiler
Where mains
pressure is low,
the supply to the
combi boiler can
be boosted via a
header tank and
single impeller
pump.
8
Instant electric
shower
Where mains
pressure is low
the supply to an
electric shower
can be boosted
via a header tank
and single impeller
pump.
9
Massage
function
We recommend a
minimum 1.5 bar
pump to ensure
good performance
through the shower
head.
Champagne
spray
We recommend a
minimum 1.5 bar
pump to ensure
good performance
through the shower
head.
If in doubt as to which Pump
to use please call
on 0191
06
516 2002
3
Instant electric
water heater
Where mains
pressure is low
the supply to an
electric shower or
water heater can
be boosted via a
header tank and
single impeller
pump.
10
Body jets
(4 max)
We recommend a
minimum 3.0 bar
pump to ensure
good performance
through the shower
head.
4
Washing machine
or dishwasher
Boost supply
of hot or cold
water or both, to
ensure continuing
pressure of supply.
11
Whole house
showers
We have a range of
house pumps for
all household needs
such as showers,
taps, bath fill and
en suite shower
rooms.
5
Conventional
shower
A conventional
shower can be
boosted depending
on the needs of the
consumer from 1.5
to 4.3 bar.
12
Toilets
We recommend 1.5
or 2.0 bar single
impeller pumps to
boost toilet flush.
6
Victorian can
shower head
Victorian can
shower heads can
be boosted by 2.0
bar shower pumps.
Large shower
heads may need
larger pumps consult PumpWise
if unsure.
13
Washbasins
We recommend
twin impeller
pumps for
monobloc mixer
taps or single
impeller pumps for
single tap supply.
Model
7
Multi-function
shower
We recommend a
minimum 1.5 bar
pump to ensure
good performance
through the shower
head.
14
Individual hot/
cold taps or bath
Depending on need,
we recommend
single impeller
pumps from 1.5 bar
for basin fill or 3.0
bar plus for bath fill
applications.
Application notes
1 CT 50, 55, 75 and 85 are supplied with 15mm hoses with isolating valves on the inlets. CT 50+, 55+, 75+, 85+, RSP 50 and
RGP 50 are supplied with 15mm hoses with isolating valves on the inlets and outlets. All remaining pumps are supplied
with 22mm hoses with isolating valves on the inlets and outlets.
2 May require RCM control modules.
Twin or
Single impeller
Bar Rating
CT 501 CT 50+
Twin
1.5
CT 751 CT 75+
Twin
2.1
CT 551 CT 55+
Single
1.6
CT 851 CT 85+
Single
2.5
RGP 50
Single
1.3
RGP 80
Single
2.4
RGP 120
Single
3.6
RSP 50
Twin
1.5
RSP 75
Twin
2.2
RSP 100
Twin
3.0
RHP 50
Twin
1.5
RHP 75
Twin
2.2
RHP 100
Twin
3.0
RHP 140
Twin
4.3
ESP 55 CPV
Single
1.5
ESP 80 CPV
Single
2.4
ESP 120 CPV
Single
3.6
ESP 150 CPV
Single
4.5
ESP 50 CPV
Twin
1.5
ESP 75 CPV
Twin
2.2
ESP 100 CPV
Twin
3.0
ESP 140 CPV
Twin
4.3
ESP 80 CPV SB
Twin singles
2.4
ESP 120 CPV SB
Twin singles
3.6
ESP 150 CPV SB
Twin singles
4.5
Force 15 PT
Twin
1.5
Force 20 PT
Twin
2.0
Force 30 PT
Twin
3.0
Force 20 PS
Single
2.0
Force 30 PS
Single
3.0
Force 15 TU
Twin
1.5
Force 20 TU
Twin
2.0
Force 30 TU
Twin
3.0
Force 20 SU
Single
2.0
Force 30 SU
Single
3.0
Twin or
le impeller
Bar Rating
Closed head Centrifugal or
Positive or
pressure
regenerative Negative head
Rating
Max
amps
Max
watts
1
2
3
4
5
Twin
1.5
50ft
Regenerative
Positive
Continuous
2.0
480

Twin
2.1
75ft
Regenerative
Positive
Continuous
2.1
500

Single
1.6
55ft
Regenerative
Positive
Continuous
2.0
450
2

Single
2.5
85ft
Regenerative
Positive
Continuous
2.1
460
2
Single
1.3
43ft
Centrifugal
Positive
Continuous
2.0
480

Single
2.4
80ft
Centrifugal
Positive
Continuous
2.4
580
Single
3.6
115ft
Centrifugal
Positive
Continuous
2.7
Twin
1.5
50ft
Centrifugal
Positive
Continuous
1.8
Twin
2.2
75ft
Centrifugal
Positive
Continuous
Twin
3.0
100ft
Centrifugal
Positive
Continuous
Twin
1.5
50ft
Centrifugal
Positive
Twin
2.2
75ft
Centrifugal
Twin
3.0
100ft
Centrifugal
6
7
8
9
10
11
12
13
14
08-09



Page
index

08-09

08-09
2

08-09
2
2
2
2





650





430

3.2
720





4.0
960





Continuous
1.8
430

Positive
Continuous
3.2
720





Positive
Continuous
4.0
960









13
13
13

11

11
11

Twin
4.3
140ft
Centrifugal
Positive
20 mins on /off
6.0
1,440





Single
1.5
50ft
Centrifugal
Pos & Neg
Continuous
1.8
430









Single
2.4
80ft
Centrifugal
Pos & Neg
Continuous
2.4
580









Single
3.6
120ft
Centrifugal
Pos & Neg
Continuous
2.7
650










Single
4.5
150ft
Centrifugal
Pos & Neg
30 mins on/off
5.0
750







Twin
1.5
50ft
Centrifugal
Pos & Neg
Continuous
1.8
430

Twin
2.2
75ft
Centrifugal
Pos & Neg
Continuous
3.2
720

Twin
3.0
100ft
Centrifugal
Pos & Neg
Continuous
4.0
960




12




12


12


12
16-17
16-17
16-17
16-17










14-15








14-15








14-15








14-15
Twin
4.3
142ft
Centrifugal
Pos & Neg
Continuous
6.0
1,440
n singles
2.4
80ft
Centrifugal
Pos & Neg
Continuous
1.8
430









n singles
3.6
120ft
Centrifugal
Pos & Neg
Continuous
3.2
720










16-17
n singles
4.5
150ft
Centrifugal
Pos & Neg
30 mins on /off
5.0
750










16-17
Twin
1.5
50ft
Regenerative
Positive
Continuous
2.0
480




Twin
2.0
75ft
Regenerative
Positive
Continuous
3.2
580





Twin
3.0
100ft
Regenerative
Positive
Continuous
4.0
960





Single
2.0
75ft
Regenerative
Positive
Continuous
3.2
580








20
Single
3.0
100ft
Regenerative
Positive
Continuous
4.0
960








21
Twin
1.5
50ft
Regenerative
Pos & Neg
Continuous
2.0
480




Twin
2.0
75ft
Regenerative
Pos & Neg
Continuous
3.2
580










Twin
3.0
100ft
Regenerative
Pos & Neg
Continuous
4.0
960
Single
2.0
75ft
Regenerative
Pos & Neg
Continuous
3.2
580








Single
3.0
100ft
Regenerative
Pos & Neg
Continuous
4.0
960








16-17
19
20
21

19


20

21
20

21
07
CT pumps
CT 50/50+/75/75+ twin impeller pumps
Robust entry level regenerative shower pumps
The new range of CT shower pumps includes even more
features in its robust, installer friendly design.
• One of the biggest selling range of shower pumps in the UK
• For installers, these compact pumps are now even easier to fit in tight
spaces with isolating valves as standard on inlet couplers
Regenerative, positive head
Tough, easy to fit general purpose
twin booster pumps, this range
will boost the hot and cold
water supplies to thermostatic
or manual shower mixer valves.
Suitable for a wide range of
shower types and heads.
Available in twin or single impeller variants,
performance ranges from 1.5 to 2.5 bar pressure.
Push fit anti-vibration couplers (AV) are supplied with all
Salamander pumps
Push fit anti-vibration
couplers have isolating
valves on the inlets on the
standard CT range.
“Great pump easy to fit
very reliable good for the
DIYer. Fit and forget, great.”
Making water perform
08
EW
M
N
CT 50+ and CT 75+ are supplied
with anti-vibration couplers and
isolating valves as standard on
both inlets and outlets.
• For householders, the re-designed foot arrangement and improved
switching will mean enhanced reliability, performance and longevity
• The CT range gives an excellent boost to hot and cold water supplies to
thermostatic shower valves and can be used with multi-function,
conventional or Victorian ‘can style’ shower heads
L
E
OD
CT 50
CT 55/55+/85/85+ single impeller pumps
Regenerative, positive head
Tough, easy to fit general purpose
single outlet pumps designed to
boost supplies to the bathroom
and the rest of the house. These
pumps will increase flow to any
tank-fed appliance.
L
E
OD
EW
N
CT 55+ and CT 85+ are supplied
with anti-vibration couplers and
an isolating valve as standard on
the inlet.
CT 85
M
CT 50&75 twin
CT twin
FT BAR
3
100
PRESSURE
75
For conventional showers and multifunction showers.
For conventional showers, Victorian
can style shower heads, multi-function
showers, massage function or
champagne spray.
Performance
Quiet*
Quiet*
1.40
1
CT 50
1.20
1.05
0.875
0.75
0.65
0.45
0.40
0
CT 75/75+ twin
Twin shower specific pumps
2 CT 75
50
25
Applications
CT 50/50+ twin
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
50ft head (1.5 bar)
2.0 amps/480 watts
65 dB
Continuous
75ft head (2.0 bar)
2.1 amps/500 watts
65.1 dB
Continuous
Shower head
CT 55&85 single
CT single
FT BAR
3
100
PRESSURE
75
2
50
25
CT 85
0
1.40
For washing machines and dishwashers
as well as conventional showers and
multi-function showers.
For washing machines and dishwashers
as well as conventional showers,
Victorian can style shower heads, multifunction showers, massage function
or champagne spray.
Performance
Quiet*
Quiet*
1.30
1.05
5
10
1.00
0.80
15
0.60
0.50
20
CT85/85+ single
To boost supplies to a variety of tankfed appliances
1.65
CT 55
1
Applications
CT55/55+ single
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
55ft head (1.6 bar)
2.0 amps/450 watts
63dB
Continuous
85ft head (2.5 bar)
2.1 amps/460 watts
63.3dB
Continuous
Shower head
* We state ‘quiet’ on our CT range of shower pumps as we believe they are quiet in operation relative to other shower pumps
available in the UK. Pumps are mechanical in operation, the movement of water in volume or at high pressure will generate some
background noise.
Key:
Victorian Can Shower heads
Conventional spray
Multi-function massage – champagne spray
Salamander Pumps
Salamander Pumps
09
Right pumps
Reliable and smooth running centrifugal shower pumps
A range of premium pumps designed for smooth running with high levels of
flow to boost pressures to appliances throughout the home. They can boost
supplies to washbasins, baths and showers, whether the requirement is
for multi-function, conventional or Victorian ‘can style’ shower heads. The
centrifugal impeller gives them quiet running with sustained pressure and
flow relative to other shower pump types.
Available in twin or single impeller variants, performances range from 1.5 to
4.3 bar pressure.
Push fit anti-vibration couplers (AV) with isolating valves
are supplied with all Right and ESP pumps
Push fit anti-vibration
couplers help make pump
installation easier.
See page 29 for more details.
The RSP 50 is the quietest 1.5 bar
shower pump available in the UK
and Ireland at
54dB
which is quieter than the average
household kettle.
General household item decibel ratings:
Normal breathing 10dB
Whisper 30dB
Running stream/refrigerator humming 40dB
Normal conversation 50 – 65dB
Laughter 60 – 65dB
Vacuum cleaner 70dB
Washing machine 78dB
Making water perform
10
Right shower pumps
Positive head
Designed purely for showers, these premium twin ended pumps boost the
hot and cold supplies to thermostatic or manual mixer valves in positive
head systems.
These pumps are capable of feeding multi-outlet applications and are supplied
with anti-vibration couplers complete with isolating valves.
The Right shower pump range achieve their quietness of operation
as they use centrifugal type impellers. Utilising centrifugal force they
are generally quieter and more flow efficient than regenerative
shower pumps.
RHP 50,75,100_NEW
Right pump
Applications
2.80
2.10
1.30
2.55
1.95
1.10
2.35
1.75
1.00
2.05
1.55
0.75
1.45
1.10
1.05
0.55
60
70
12 13 14 15
RSP 50
RSP 50 twin
RSP 75 twin
Quiet running pumps for
showers. Not suitable to
boost toilets, washing
machines or individual
hot and cold taps.
Purpose made for one
or more conventional
shower heads and
multi-function showers.
As the RSP 50 twin
plus showers with a
massage function or
champagne spray.
Performance
Quieter*
Quieter*
Closed head pressure
Max amps/watts
Typical Decibel Rating
Rating
50ft head (1.5 bar)
1.8 amps/430 watts
54dB
Continuous
75ft head (2.2 bar)
3.2 amps/720 watts
55.4dB
Continuous
RSP 100 twin
As RSP 50 and RSP 75
plus up to four body jets.
Definitely the Right
choice for 3.0 bar
shower heads.
Quieter*
100 ft head (3.0 bar)
4.0 amps/960 watts
57.6dB
Continuous
Shower head
* We state ‘quieter’ on our centrifugal range of pumps as they are quiet in operation relative to other shower pumps available.
Pumps are mechanical in operation and the need to move water in volume or at high pressure will generate some background noise.
Key:
Victorian Can Shower heads
Conventional spray
Multi-function massage
– champagne spray
3 bar shower heads
Body sprays
Salamander
Pumps
Multiple body sprays
Salamander Pumps
11
Right whole house pumps
Positive head
Designed specifically for whole house systems, or just the bathroom,
these twin-ended premium pumps are uniquely equipped to handle single
or multi-outlet use, i.e. the hot or cold taps being used individually or both
at the same time.
These pumps are supplied with isolating valve anti-vibration couplers.
RHP 75
RHP 45,75&100&140
Right pump
Applications
4.00
2.80
2.10
1.30
25
3.70
3.15
2.55
1.95
1.10
2.35
1.75
1.00
2.05
1.55
0.75
2.30
Quiet running, high
performance pumps for
the whole house
including toilets,
washbasins or individual
hot and cold taps.
Houses and flats with
low resistance outlets.
Conventional showers,
whole house showers,
toilets, washbasins,
baths, individual hot and
cold taps.
Performance
Quieter*
1.70
1.45
1.05
RHP 50 twin
1.10
0.55
60
70
12 13 14 15
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
50ft head (1.5 bar)
1.8 amps/430 watts
54dB
Continuous
RHP 75 twin
As the RHP 50 whole
house pump for
houses and flats but
also suitable for high
resistance outlets
such as multi-function
showers and showers
with a massage function
or champagne spray.
Quieter*
75ft head (2.2 bar)
3.2 amps/720 watts
55.4dB
Continuous
RHP 100 twin
RHP 140 twin
The RHP 100 and RHP 140 have the same
application specifications as the RHP 50 and RHP
75 but can also power showers with up to four
body jets.
Quieter*
100 ft head (3.0 bar)
4.0 amps/960 watts
57.6dB
Continuous
Quieter*
140 ft head (4.3 bar)
6 amps/1440 watts
60.8dB
20 mins on/off
Shower head
* We state ‘quieter’ on our centrifugal range of pumps as they are quiet in operation relative to other shower pumps available.
Pumps are mechanical in operation and the need to move water in volume or at high pressure will generate some background noise.
Making water perform
12
Right single pumps
Positive head
An innovative range of premium single outlet pumps.
They are compact and smooth running with sustained flow and come
supplied with isolating valves on the anti-vibration couplers.
“Excellent product which produces a really good surge for a gravity fed shower.
Amazingly cheap for such good quality and also very easy to fit.
The pump is also very compact so excellent for confined spaces and transforms a
poor or average flow shower into an exceptionally powerful one. The pump can also
be fitted several metres from the shower and still be extremely efficient.”
Right pump
Applications
3.18
2.81
2.15
RGP 50
1.09
1.81
RGP 50 single
RGP 80 single
The right single pump
to boost supplies to a
variety of appliances.
The ideal pump for
a washing machine,
dishwasher or a
conventional shower.
As the RGP50 and will
also power Victorian
can shower heads,
multifunction showers,
massage functions and
champagne sprays.
Performance
Quieter*
Quieter*
2.21
1.39
1.00
RGP 80
RGP 120 single
As the RGP50 and
RGP80 and will power
up to four body jets.
0.72
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
43ft head (1.3 bar)
2.0 amps/480 watts
55dB
Continuous
80ft head (2.4 bar)
2.4 amps/580 watts
58dB
Continuous
Quieter*
115ft head (3.6 bar)
2.7 amps/650 watts
62.6dB
Continuous
Shower head
* We state ‘quieter’ on our centrifugal range of pumps as they are quiet in operation relative to other shower pumps available.
Pumps are mechanical in operation and the need to move water in volume or at high pressure will generate some background noise.
Key:
Victorian Can Shower heads
Conventional spray
Multi-function massage
– champagne spray
3 bar shower heads
Body sprays
Salamander
Pumps
Multiple body sprays
Salamander Pumps
13
ESP CPV pumps
ESP 50 CPV and ESP 75 CPV twin
Positive and/or negative head systems
Reliable and smooth running centrifugal pumps that
can operate in positive or negative head installations
Salamander’s electronic range of premium shower and whole house
pumps, take away the confusion of which pump to buy for the respective
plumbing system as they are capable of working in positive and negative
head installations. The ESP CPV pumps are a result of extensive research
to develop these advanced pumps that incorporate micro-electronic
technology and sensors. Quiet running relative to other shower pump types,
they are reliable and high in quality.
The first intelligent shower pump with electronic system protection (ESP),
can be used for appliances throughout the home, boosting supply to
washbasins, baths and showers. The high pressure variants can also be used
to boost supplies to body jets and steam cabinets. Available in twin or single
impeller variants, performances range from 1.5 to 4.5 bar pressure.
Automatic pump
protection and simple
LED indication
Clear indicators on the top of
the pump show the electronic
system protection is working
correctly.
Making water perform
14
N
Negative head operation
P
Positive head operation
1
System hunting protection
2
Dry run protection
3
Supply water temperature
protection
Designed specifically for one or
two bathroom systems where
there is a need to boost baths,
basins or showers which may
be above and/or below the cold
water storage tank(s), typically
flats, loft and barn conversions.
These pumps are supplied with
isolating valve anti-vibration
couplers.
ESP 50 CPV twin
ESP 100 CPV and ESP 140 CPV twin
Positive and/or negative head systems
As ESP 50 CPV and ESP 75 CPV
twin above, but also suitable for
systems where there is a need for
greater performance or flow, e.g.
shower columns, steam cubicles and
multiple body sprays.
These pumps are supplied with
isolating valve anti-vibration
couplers.
ESP 100CPV twin
ESP CPV twin
Applications
For flats and houses where the
requirement is for a positive and/or
negative head pump.
2.10
1.30
1.95
1.10
1.75
1.00
1.55
1.05
0.75
ESP 50 CPV twin
ESP 75 CPV twin
For tank-fed shower and/or whole
house systems in flats and houses
where the pressure requirement is up to
1.5 bar (30-42ft head). For conventional
showers, multi-function showers, whole
house showers, toilets, washbasins and
individual hot/cold taps/bath.
As the ESP 50 CPV plus multiple shower
systems where the pressure
requirement is up to 2.2 bar
(65-75ft head).
Quieter*
Quieter*
Also suitable for showers with a
massage function or champagne spray.
0.55
60
12 13
Performance
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
50ft head (1.5 bar)
1.8 amps/430 watts
54dB
Continuous
75ft head (2.2 bar)
3.2 amps/720 watts
55.4dB
Continuous
Shower head
ESP CPV twin
Applications
4.00
2.80
3.70
2.55
3.15
2.05
60
1.70
1.40
1.10
70
80
12 13 14 15 16 17
ESP 140 CPV twin
As ESP 50/75 CPV above but where
there may also be shower columns,
steam cubicles or body jets/sprays.
As ESP 75 CPV above but also where
there may be up to four body jets in the
system where the pressure
requirements is up to 3.0 bar
(100ft head).
As ESP 100 CPV and where the
pressure requirement is up to 4.3 bar
typically in pre-formed shower columns
and cubicles.
Performance
Quieter*
Quieter*
2.30
1.45
ESP 100 CPV twin
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
100ft head (3.0 bar)
4 amps/960 watts
57.6dB
Continuous
142ft head (4.3 bar)
6 amps/1440 watts
60.8dB
20 mins on/off
Shower head
* We state ‘quieter’ on our centrifugal range of pumps as they are quiet in operation relative to other shower pumps available.
Pumps are mechanical in operation and the need to move water in volume or at high pressure will generate some background noise.
Key:
Victorian Can Shower heads
Conventional spray
Multi-function massage
– champagne spray
3 bar shower heads
Body sprays
Salamander
Pumps
Multiple body sprays
Salamander Pumps
15
ESP pumps continued
“Excellent value for money.
Terrific power from this size of pump.
Fitting made easy due to push fit
connections. As a 3 point plug is already
fitted there are no wiring difficulties.
As a plumber I have fitted several of
these and will be back for more.”
“Nice solid feel to it and works
beautifully. It is so quiet when running,
I thought it hadn’t switched on!!
The old pump used to wake everyone up
if used early but this really is great.”
ESP 80 CPV and ESP 120 CPV single
Positive and/or negative head systems
These single pumps boost
supplies to a variety of
appliances from tank-fed
systems, and are suitable for
both positive and negative head
systems.
Selection should be based on
pressure requirements.
These pumps are supplied with
isolating valve anti-vibration
couplers.
ESP 80 CPV single
ESP CPV super boosters
Positive and/or negative head systems
The choice of super booster is
determined by establishing the
pressure required at the outlets.
These boosters are suitable for
both positive and negative head
systems and these pumps are
supplied with isolating
valve anti-vibration couplers.
ESP 120CPV super booster
Making water perform
16
ESP CPV single
Applications
4.20
ESP 150
3.75
3.18
2.81
2.15
1.81
3.10
2.21
1.39
ESP 55 CPV single
ESP 80 CPV single
ESP 120 CPV single ESP 150 CPV single
To boost tank-fed
supplies to combination
boilers, instantaneous
electric showers,
instantaneous electric
water heaters, and
washing machines/
dishwashers – according
to inlet pressure
requirements.
These pumps will also power conventional showers, Victorian shower heads, multi-function showers,
showers with massage functions or champagne spray. The ESP 120 CPV and ESP 150 CPV will also power
up to four body jets. Consult PumpWise for help selecting the correct pump, see page 22.
Performance
Quieter*
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
50ft head (1.5 bar)
1.8 amps/430 watts
58dB
Continuous
Quieter*
Quieter*
80ft head (2.4 bar)
2.4 amps/580 watts
58dB
Continuous
120ft head (3.6 bar)
2.7 amps/650 watts
60.4dB
Continuous
Quieter*
150ft head (4.5 bar)
5 amps/750 watts
62.6dB
30 mins on/off
Shower head
ESP CPVSB
Applications
ESP 150
4.20
3.18
2.15
3.75
2.81
1.61
3.10
2.21
1.39
ESP 80 CPVSB
ESP 120 CPVSB
ESP 150 CPVSB
Created to meet the
requirements of those who
live in larger houses or whose
idea of a really good shower
is a total deluge.
Each Super Booster comprises two single pumps, one each to independently boost tank-fed hot
and cold water services. These pumps can be positioned together or remotely one from the other.
Application specification is the same as single versions above.
Performance
Quieter*
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
80ft head (2.4 bar)
1.8 amps/430 watts
58dB
Continuous
Quieter*
120ft head (3.6 bar)
3.2 amps/720 watts
60.4dB
Continuous
Quieter*
150ft head (4.5 bar)
5 amps/750 watts
62.6dB
30 mins on/off
Shower head
* We state ‘quieter’ on our centrifugal range of pumps as they are quiet in operation relative to other shower pumps available.
Pumps are mechanical in operation and the need to move water in volume or at high pressure will generate some background noise.
Key:
Victorian Can Shower heads
Conventional spray
Multi-function massage
– champagne spray
3 bar shower heads
Body sprays
Salamander
Pumps
Multiple body sprays
Salamander Pumps
17
W
NE
W
NE
FORCE Pumps
FOR
The new range of brass ended regenerative shower pumps
from Salamander.
PRESSURE (bar)
2.5
Individual Hot/
Cold Taps/Bath
Whole House
Installations
Body Jets (Max 4)
Champagne Spray
Massage Function
Multi-Function Shower
FORCE 30
Pg. 21
FORCE 15 PT
FORCE 20 PT
2
FORCE 30 PT
1.5
1
FORCE 20 PS
†
**
FORCE 30 PS
†
**
0.5
FORCE 15 TU
0
FORCE 20 TU
AT 20 L/MIN
AT 10 L/MIN
FORCE 30
FORCE 20
Making water perform
18
Victorian can
head shower
3
Conventional Shower
ANDER PU
M
AM
3.5
Washing Machine/
Dishwasher
To a Combi Boiler
on 0191 516 2002
FORCE 20
Pg. 20
Instant Electric
Water Heater
SA
L
PS
The standard warranty on the Force range of shower pumps is
3 years. The warranty can be extended to 5 years by registering
the installation with:
FORCE 15
Pg. 19
Instant Electric Shower
S WARRA
AR
N
YE
TY
5
Quieter than our competitors equivalent products,
the whole of the range operates at 60dB or under.
FORCE 15
FORCE 30 TU
FORCE 20 SU
FORCE 30 SU
**
**
** Check with manufacturer’s minimum pressure requirements. † When installed via a cold water storage tank.
W
5
PS
FORCE 15 PT / FORCE 15 TU
ANDER PU
M
AM
A range of brass ended 1.5 bar shower pumps
– ideal for boosting shower performance
SA
L
FORCE 15
FOR
S WARRA
AR
N
YE
TY
NE
FORCE 15 PT
“I bought this shower pump to replace another, a well known brand
beginning with T! - This is a much better pump, quiet, more powerful
and cost about the same.
The previous pump was one of three that have lasted, on average,
2-3 years each. We do have a lot of showers here but I’m confident
that this pump will outlast the others already.”
New solid state
switching on
the pump for
outstanding
reliability and
repeatability.
1.5 bar twin brass ended positive head
shower pump
Performance
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
Quieter*
50ft head (1.5bar)
2.0 amps/480 watts
56dB
Continuous
Shower head
FORCE 15 TU
1.5 bar twin brass ended positive and
negative head universal shower pump
Performance
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
Quieter*
50ft head (1.5bar)
2.0 amps/480 watts
56dB
Continuous
Shower head
Continuously rated motor as used in the
Salamander CT50, the UK’s best selling
shower pump and another proven performer.
Key:
Victorian Can Shower heads
Solid brass, Salamander
branded end caps for
robustness and durability.
Conventional spray
* We state ‘quieter’ on the Force range of pumps as they are quiet in operation relative to other brass
shower pumps available. Pumps are mechanical in operation and the need to move water in volume
or at high pressure will generate some background noise.
Multi-function massage
– champagne spray
3 bar shower heads
Body sprays
Salamander
Pumps
Multiple body sprays
Salamander Pumps
19
W
W
5
PS
FORCE 20 PT / FORCE 20 TU / FORCE 20 PS / FORCE 20 SU
SA
L
FORCE 20
FOR
S WARRA
AR
N
YE
TY
NE
ANDER PU
M
AM
A range of brass ended 2.0 bar shower pumps
– ideal for providing powerful shower performance
FORCE 20 PT
FORCE 20 TU
2.0 bar twin brass ended positive head
shower pump
2.0 bar twin brass ended positive and
negative head universal shower pump
Performance
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
Quieter*
75ft head (2.0bar)
3.2 amps/580 watts
56dB
Continuous
Performance
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
Quieter*
75ft head (2.0bar)
3.2 amps/580 watts
56dB
Continuous
Shower head
Shower head
FORCE 20 PS
FORCE 20 SU
2.0 bar single brass ended positive head
shower pump
2.0 bar single brass ended positive and
negative head universal shower pump
Performance
Performance
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
Quieter*
75ft head (2.0bar)
3.2 amps/580 watts
56dB
Continuous
Shower head
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
Quieter*
75ft head (2.0bar)
3.2 amps/580 watts
56dB
Continuous
Shower head
* We state ‘quieter’ on the Force range of pumps as they are quiet in operation relative to other
brass shower pumps available. Pumps are mechanical in operation and the need to move water in
volume or at high pressure will generate some background noise.
Making water perform
20
NE
W
5
PS
FORCE 30 PT / FORCE 30 TU / FORCE 30 PS / FORCE 30 SU
SA
L
FORCE 30
FOR
S WARRA
AR
N
YE
TY
ANDER PU
M
AM
NE
A range of brass ended 3.0 bar shower pumps
– ideal for powerful showering and multi-outlet applications
FORCE 30 PT
FORCE 30 TU
3.0 bar twin brass ended positive head
shower pump.
3.0 bar twin brass ended positive and
negative head universal shower pump.
Performance
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
Quieter*
Performance
100ft head (3.0bar)
4.0 amps/960 watts
60dB
Continuous
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
Quieter*
100ft head (3.0bar)
4.0 amps/960 watts
60dB
Continuous
Shower head
Shower head
FORCE 30 PS
FORCE 30 SU
3.0 bar single brass ended positive head
shower pump.
3.0 bar single brass ended positive and
negative head universal shower pump.
Performance
Performance
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
Quieter*
100ft head (3.0bar)
4.0 amps/960 watts
60dB
Continuous
Closed head pressure
Max amps/watts
Typical Decibel rating
Rating
Shower head
Quieter*
100ft head (3.0bar)
4.0 amps/960 watts
60dB
Continuous
Shower head
* We state ‘quieter’ on the Force range of pumps as they are quiet in operation relative to other
brass shower pumps available. Pumps are mechanical in operation and the need to move water in
volume or at high pressure will generate some background noise.
Key:
Victorian Can Shower heads
Conventional spray
Multi-function massage
– champagne spray
3 bar shower heads
Body sprays
Salamander
Pumps
Multiple body sprays
Salamander Pumps
21
PumpWise
An initiative to help customers
PumpWise is the cornerstone of Salamander’s support
service to customers and the means by which our
customers are guaranteed:
• Selection of the right pump for the job
• The avoidance of installation pitfalls
• A third year’s warranty FREE on CT, RSP, RGP, RHP & ESP pumps
• Third and fourth year warranty FREE on all Force pumps
Selecting the right pump for the job
We offer technical assistance, guidance or advice to anyone who asks.
Contact our PumpWise team.
Eliminate the risk of an incorrect installation
If your installation is not straightforward or if you have any reservations or
doubts, contact our PumpWise team.
Extend your warranties free of charge
On the CT, RSP, RGP, RHP & ESP ranges get your warranty extended to 3
years free of charge. On the Force brass range get your warranty extended
to 5 years free of charge. All you have to do is contact our PumpWise team,
register and follow our engineer’s installation advice.
On-site nationwide support
To resolve any on-site technical issues contact us. A Salamander engineer
will endeavour to resolve your problem quickly over the phone, or if
that’s not possible, arrange an on-site visit from one of our Salamander
service engineers.
Making water perform
22
For PumpWise help, guidance or advice simply call
0191 516 2002
(08.30-17.30 Mon - Thurs, 08.30-17.00 Fri)
Sales & Technical: 0191 516 2002
Fax:
0191 548 4445
Email:
[email protected]
[email protected]
Warranty
Two years warranty
Salamander customers benefit from a two year warranty on the CT, RSP, RGP, RHP
and ESP ranges. This warranty will operate from date of purchase and is subject to
the installation guidelines being followed correctly.*
Three years warranty
Salamander customers benefit from a standard three year warranty on the new
brass ended FORCE range. This warranty will operate from date of purchase and is
subject to the installation guidelines being followed correctly.*
Third, fourth & fifth year warranty FREE
Under the PumpWise Scheme customers who consult Salamander and register
the pump by phone immediately after installation, and who implement our
recommendations, will benefit from a third year warranty FREE on the CT, RSP,
RHP, RGP & ESP ranges. They will enjoy an extra two years warranty free on the
FORCE range.
The Extended Warranty Scheme
Your pump warranty can be extended for an additional three years on the CT, RSP,
RHP, RGP & ESP ranges only.
The Extended Warranty Scheme exists to protect customers from unexpected or
unforeseen pump breakdown.
Under the Extended Warranty Scheme we guarantee to repair or replace your
pump FREE* for a further three years on top of your existing warranty.
Participation in the Extended Warranty Scheme is activated on completion of a
direct debit mandate for payment of a nominal designated amount. Call sales on
0191 516 2002 and ask for details.
*Due to the technical nature of our pumps, please ensure that you follow our fitting
guidelines carefully as failure to do so could invalidate the pump’s warranty.
Precision
robotic
measuring tools
are used to ensure consistency
of pump housing diameters.
100%
of our products are tested
prior to leaving the factory.
Salamander Pumps
Salamander Pumps
23
Customer service
Sales
Our experienced team of internal sales
operators are on hand to advise on all enquiries
relating to sales orders and to advise on which
pump best fits your application.
On average,
we receive
in excess of
For sales help
Tel: 0191 516 2002
Fax: 0191 548 4445
Email: [email protected]
Mon - Thu
08:30 - 17:30
Fri
08:30 - 17:00
Technical advice
Our knowledgeable team of technical
advisers are at the end of the phone to
answer any queries of a technical nature
whether pre or post installation.
With over 70 years combined plumbing
experience, they are well equipped to handle
any technical enquiry from householders
and installers alike.
For technical help
Tel: 0191 516 2002
Email: [email protected]
Mon - Thu
08:30 - 17:30
Fri
08:30 - 17:00
Making water perform
24
We answer
350
90%
calls per day
of incoming calls in
less than a minute
Training
We offer dedicated
training with our
Training Manager for
Installers, Merchants,
Showroom Staff and
Colleges which can be
arranged by calling
0191 516 2002.
Do you need help selecting the right pump for your application?
Then either call PumpWise on 0191 516 2002 and they will walk you
through a pump selection process or they can send you
our new interactive CD.
General specification
Applications
Anti-vibration couplers
Electrical rating
All Salamander pumps are designed to boost low
pressure hot and cold supplies from tank-fed
services. When supplies from a water heater or a
combination boiler are to be boosted contact the
Salamander PumpWise helpline
0191 516 2002 for guidance.
CT50, 55, 75 and 85 are supplied with 15mm hoses
with isolating valves on the inlets. CT 50+, 55+, 75+,
85+, RSP 50 and RGP 50 are supplied with 15mm
hoses with isolating valves on the inlets and outlets.
Single Pumps – continuous. Except for ESP 150 CPV
single and ESP 150 CPVSB which are 30 mins on/off.
All remaining pumps are supplied with 22mm hoses
with isolating valves on the inlets and outlets.
All Salamander pumps are fitted with a mains lead
and an appropriately fused moulded three-pin plug,
except for the ESP 140 CPV and RHP 140.
Voltage
Mechanical seals
220-240 volts 50 Hz.
Motor type
Capacitor start and run induction type motor with
stainless steel shaft and in-built resetting thermal
protection (complies with BS5000 part 11).
Rotary mechanical face seals comprise a carbon
rotary element and a ceramic counter face. This
combination is resistant to mineral deposits and
to abrasion.
Connections
Twin pumps continuous except RHP 140 and ESP
140 CPV which are 20 mins on/off.
Continuous improvement
The company operates a policy of continuous
development and reserves the right to change any
of the specifications of its products without prior
notice. All information data, and illustrations given
may be subject to variation.
Pump materials
3/4” BSP male.
Standards and approvals
All moulded components are manufactured from
WRAS approved Acetal Copolymer.
Initiation
Splash proof rating IPX2.
Maximum head
ESP 50 CPV
5 metres
CT50/50+/55/55+/75/75+/85/85+
15 metres
All other pumps
10 metres
Pumps fitted with RCM3 maximum 3 metres
static head.
ESP CPV pumps are fully automatic for both positive
and negative head systems. All other pumps
require a natural flow of at least 2 litres per minute
of combined hot and cold outlets for automatic
operation in positive head systems.
Temperature
Complies with the requirements of current British
and European safety standards for household and
similar electrical appliances.
Complies with European Community Directives (CE).
Due to continuous improvement and updating,
specifications may be altered without prior notice.
Maximum fluid temperature 65ºC. ESP CPV pumps
will automatically stop running if the hot water
temperature exceeds acceptable limits.
Salamander Pumps
Salamander Pumps
25
Typical Right Pump and ESP CPV Pump applications
Positive head system
Pump fitted above cylinder
Usable capacity
minimum 50 gallons
per bathroom
Usable capacity
minimum 50 gallons
per bathroom
Air vents, both
hot and cold
Min
600mm
Positive
head
Cold water cistern
Cold water
cistern
Inlet
Negative head system
S
Air vents, both
hot and cold
Outlets
C
H
Shower head
Hot water cylinder
Shower valve
The hot
connection
must be via
an approved
side or top
entry flange
MAX
65°C
H
RSP Twin Pump with up and over pipework and natural flow of
1Litre/min per side.
G
Cold water cistern
No Stop Essex Flange
MUST be used with an
anti-gravity loop at least
200mm in depth
Vent and other
services
Hot water cylinder
Bas
The hot
connection
must be via
an approved
side or top
entry flange
Pump fitted in loft above cylinder. Must use no stop Essex
flange and anti-gravity loop.
MAX
65°C
Pump
Outlets
Inlet C
H
Inlet
Lar
ind
ESP CPV Twin Pump to a bathroom in a loft conversion.
Pump feeding two showers
Whole house system
Usable capacity
minimum 50 gallons
per bathroom
Positive
head
Vent and other
services
C
The hot
connection
must be via
an approved
side or top
entry flange
H
Pump Inlet
Cold water
cistern
Positive head
Shower valve
Outlets
Usable capacity
minimum 50 gallons
per bathroom
Cold water cistern
Shower head
Hot water
cylinder
MAX
65°C
Pump on steam cabinet
Usable capacity
minimum 50 gallons
per bathroom
Cold water cistern
Fit an
equilibrium
ball valve
Vent and other
services
The hot
connection
must be via
an approved
side or top
entry flange
Fit an
equilibrium
ball valve
Shower head
Pump
Pump
Inlet
Shower valve
Usable capacity
minimum 50 gallons
per bathroom
Shower valve
MAX
60°C
Non-return valve
hot outlet only
Outlets
C
Hot water
cylinder
Vent and other
services
NEGATIVE HEAD
Non-return valve
hot outlet only
Shower head
Vent and other
services
La
Min
600mm
Inlet
Hot water
cylinder
Shower head
Pu
pr
Air vents, both
hot and cold
Outlets
C
H
Pump
Shower head
Shower valve
MAX
65°C
Pump
Outlets
C
H
Inlet
Vent and other
services
RSP Twin Pump feeding two showers.
MAX
60°C
Shower valve
No Stop Essex Flange
MUST be used with an
anti-gravity loop at least
250mm in depth
C
Hot water cylinder
RHP Twirl Pump on a whole house system.
ESP CPV Pump fitted above cylinder on a steam shower cabinet.
Making water perform
26
Tan
to
to
Large whole house system
Large whole house system
Combi with CWS tanks and cylinder
Cold water cistern
Usable capacity
minimum 50 gallons
per bathroom
Whole House
•
Shower head
Shower valve
8ft
Second
Fit an
librium
ll valve
Fit an
equilibrium
ball valve
Usable capacity
minimum 50 gallons
per bathroom
Cold water cistern
MAXIMUM
10 METRES
Shower valve
Pump
7ft
Basement
MUST USE
No Stop
Essex Flange
with 3 inch
insert into
cylinder
Shower head
•
Vent and
other
services
Fit an
equilibrium
ball valve
MAX
60°C
Hot water cylinder
Hot water cylinder
MAX
65°C
Positive
head
Outlets
C
Cylinder heated
by Economy Seven
or indirectly from the
combination boiler
H
Shower head
Pump
Shower valve
MAX
65°C
H
•
Shower valve
Whole
house
antigravity
loop
Vent and other
services
Cold water cistern
The hot
connection
must be via
an approved
side or top
entry flange
8ft
Ground
Hot water
cylinder
Usable capacity
minimum 50 gallons per bathroom
Shower head
Pump
Min
600mm
Pump
Pump
Combi
boiler
Washing
machine
Large whole house system with the ESP CPV SB hot and cold pumps
independently mounted with hot pump above cylinder.
Incoming
water mains
Large whole house system with the ESP CPV SB hot and cold pumps
mounted in the airing cupboard.
Combi boiler system with RSP twin pump to boost the shower from a
CWS tank and a direct cylinder.
Pumped tank supplies to combi or
pressurised cylinder
Multiple showers
Pumping hot water only
Usable capacity
minimum 50 gallons
per bathroom
Min
600mm
Cold water cistern
Positive
head
Cold water cistern
Usable capacity
minimum 50 gallon
per bathroom
Shower head
Pump
Hot water
cylinder
MAX
65°C
MAX
65°C
•
Incoming cold water mains
Hot water
cylinder
MAX
65°C
Shower valve
Combi
boiler
Shower head
Mixer valve
Vent and other
services
Sports complex with multiple showers.
Pump
Shower valve
Double action
non-return valves
Incoming cold water mains
Tank-fed (hot) with cw mains cold systems MUST USE Right ESP CPV.
H
Pump
Tank-fed, pressurised cylinder or combi boiler system with ESP CPV single
to boost the hot supply water pressure and cold water mains supplies “cold”
to shower, bath, basin and toilet.
Salamander Pumps
Salamander Pumps
27
S flange
Salamander’s uniquely different top entry DZR cylinder flange
• Plumbing is not an exact science and aeration of the supply water to
showers and other outlets is a common problem.
• When a pump is fitted to boost the supplies from the cold water storage
tank and from the cylinder to showers, baths and basins the risk of
aeration is increased many times.
Typical pipework
arrangement
Systems without a
flange will risk
aeration of the supply
water to the pump.
Aerated supply water to pumps and to showers and other outlets means an
increased risk of:
• Unnecessary, perhaps sudden temperature fluctuation at the shower or
other outlets.
• A noisy pump.
• Premature pump breakdown.
MAX
65°C
Cold feed
to cylinder
Pump
A correctly fitted approved cylinder flange will mitigate if not prevent
these risks.
22mm compression
outlet to the pump
1” BSP female adaptor to facilitate connection
to both female and male outlet cylinder
S flange
The S flange will
encourage aeration
to follow a natural
path to vent and
prevents aerated
supply water being
drawn into the pump.
To vent
S flange
HOT WATER
CYLINDER
28mm compression fitting includes
a 28mm x 22mm reducing set
Making water perform
28
To pump
Hot water supply
blending valve
The hot water supply blending valve is
designed to protect booster pumps fitted to
systems where the stored domestic hot water
temperature is uncontrolled e.g. Aga, solid fuel
appliances or automatic boilers very crudely
controlled by the boiler thermostat.
Example shows a centrifugal twin pump with hot
water supply blending valve protection.
Usable capacity minimum
50 gallons per bathroom
and 30 gallons per en suite
Vent and other
services
Can be off the vent
if the distance is
at least 1 metre
Surrey or
No Stop
Essex flange
Outlets
Inlet C
H
Inlet
Hot water supply blending valve controller is
factory set at 55-60°C
Anti-vibration couplers
All Salamander pumps are supplied with antivibration (AV) couplers in order to limit the
transfer of pump vibration to the associated
pipe work.
The beneficial effect of anti-vibration (AV)
couplers is lost if they are bent or twisted
on installation.
CT50, 55, 75 and 85 are supplied with 15mm
hoses with isolating valves on the inlets. CT
50+, 55+, 75+, 85+, RSP 50 and RGP 50 are
supplied with 15mm hoses with isolating valves
on the inlets and outlets. All remaining pumps
are supplied with 22mm hoses with isolating
valves on the inlets and outlets.
Each pump whether a single or twin pump is
supplied with one or two straight and angled
anti-vibration (AV) couplers. This arrangement
of couplers facilitates the connection of the
supply pipework from any direction.
Salamander Pumps
Salamander Pumps
29
Salamander Pumped Shower Systems Limited
Unit 2c Colima Avenue, Enterprise Park West,
Sunderland, SR5 3XE
Telephone: 0191 516 2002
Facsimile: 0191 548 4445
Email:
[email protected]
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement