Product Selection Guide Satchwell Control Systems Ltd Advanced Building Systems Farnham Road Slough Berkshire SL1 4UH United Kingdom Telephone +44 (0) 1753 611000 Facsimile +44 (0) 1753 611001 Website www.satchwell.com An Invensys Controls Company Printed in England 12/04 © 2004 Satchwell Control Systems Ltd All rights reserved INDEX Welcome to this new edition of our Product Selection Guide, encompassing Satchwell, Drayton and Controlli products in a single publication, complete with recommended retail prices. The Guide is designed to make it as easy as possible for you to identify the items you need, for both new projects and replacement of installed items. Range Description MICRONET SYSTEM Software VisiView MicroNet View VisiSat™ Configuration Tool WorkPlace Tech Tool Remote Alarm Manager CSM Tool Controllers (LONMARK®) MN 11 & 13 Fan Coil Unit Controller MN 50 Programmable Controller MN 100, 150 & 200 Programmable Controllers VAV Controllers with/without Integral Actuator Controllers (Bus-du-jour®) MN 300, 440 Controllers with NCP MN 500, 620 Controllers with NCP Digital Modules Digital Output Module Fan Coil Unit Solutions Bonsai® Pro & Lite Fan Coil Unit Controller UniFact® Pro Terminal Unit Controller Interfaces Manager Interface with Bus-du-jour ARCNET® Router Touch Screen Display LCD Display Digital Room Temperature Sensors Sensors Room Temperature Sensors Valves Bonsai Fan Coil Unit Valves USING THE PRODUCT SELECTION GUIDE Index Pages The individual products are listed in the order that they appear in the main section of the Guide. If they also appear in the Product Compatibility and Obsolete Product sections, the relevant page numbers are shown in the adjacent columns (applies only to Satchwell brand products). Brands Drayton brand products can be found on page 34 Controlli brand products and supporting information can be found on pages 66 - 74 The remainder of the Guide is devoted to Satchwell brand products. Data Sheets The Guide provides a convenient summary of the functionality and technical specification of each product. For full technical information, the reference number of the relevant data sheet is shown. DRAYTON RANGE FURTHER INFORMATION We provide a series of additional resources in the form of printed documentation, electronic files, an Internet site, and the services of our Customer Care Centre. Details are shown below. Product Range Catalogue The Product Range Catalogue is a compendium of all our data sheets. It is available in both CD-ROM and ring binder formats. Contact Customer Care to obtain a copy. Web Site Check our total portfolio by visiting our Internet site at www.satchwell.com, which also gives direct access to the latest versions of all our data sheets in pdf format. Customer Care Centre Our Customer Care Centre is available to answer all your questions, and can put you in direct contact with the sales office responsible for your area. Customer Care details are as follows: Tel: +44 (0) 1753-611000 Fax: +44 (0) 1753-611001 Email: [email protected] Controllers Self Configuring Optimiser/Compensator Sensors Room, outside, immersion, duct and surface Relay and Switching Units Relay Units Remote Switch Unit (RSU) SATCHWELL Optimiser CONTROLLERS 7-day Optimiser Compensator Compensator Controller Main Plant Controllers AHU Room Reset Controller PID Pulse Controller PID 0...10V Controller Keyboard C/O Step Control Function Module Multiple Application PID Controller Universal Air Handling Unit Controller Multi-Loop District Heating Controller Terminal Unit Fan Coil Unit Controller Networking Modem Interface Unit Intelligent/Programmable Universal Multi-loop Intelligent Advanced Controllers Touchscreen for IAC Controllers SENSORS Price List Product Selection Product Compatibility Obsolete Products VV-LITE, VV-LITE-TO-STD, VV-STANDARD MN-VW, MN-VWP, MN-VWIO MN-VSCORE, MN-VSLON WP-TECH MN-RAM, MN-RAM-OUT CSM-CORE 6 6 6 6 6 6 25 25 25 26 26 26 - - MN MN MN MN 6 6 6 6 26 27 27 27, 28 53 53 53 53 - MN 300, MN 440 MN 500, MN 620 6 6 28 29 53 53 - 579-1-360 9 30 - - BRC URC 7 7 31 31 53 53 - MN MI MNA R10 MN TS, MNL TS MN LCD, MNL LCD MN Sx 7 7 7 7 7 32 32 32 32 33 - - DU, DUS, DUSF 7 33 - - BFB 8 31 - - DC1100, DC1100C 8 34 - - A type 8 34 - - RB 04 03 109 8 8 34 34 - - SVT 9 35 53 55 CSC 9 35 53 55 CXR CXT CZT 9 9 9 35 36 36 53 53 53 56 56 56 FLS KMC MMC MMC 9 9 9 9 36 36 37 37 53 53 53 55 55, 56 55, 56 55, 56 CZU 9 37 53 55 MIU 9 38 - - IAC 420, IAC 600 IAC-TS 9 9 38, 39 39 - - DR/DRT DRT DU, DUS, DUSF DRTE DRH, DRTH DRCO 10 10 10 10 10 10 39 40 40 40 40 41 53 53 53 - 56 56 56 - DDT DDU DDH, DDTH 10 10 10 41 41 41 53 53 53 56 56 56 Code Room Temperature & Humidity Sensors Air Temperature Sensors Temperature Sensors with Fan Speed Switches UniFact Pro and MicroNet Sensors Active Temp. Sensors with/without Fan Speed Switches Humidity/Temperature Sensors Carbon Dioxide Sensors Duct Temperature, Humidity, Pressure & Air Velocity Sensors Air Temperature Sensor Fan Coil Unit Return Air Temperature Sensors Humidity/Temperature Sensors 3 11, MN 13 50 100, MN 150, MN 200 VAV INDEX INDEX Range Description Code Price List SENSORS (cont) Duct Temp., Humidity, Pressure & Air Velocity Sensors (cont) Differential Air Pressure Sensor Air Velocity Sensor Carbon Dioxide Sensors DDP DDV DDCO 10 10 10 41 42 42 - 57 - Pipe Temperature Sensors Water Temperature Sensor (Surface Pipe) Water Temperature Sensor (Immersion) Fast Response Water Sensor (Immersion) DST DWT DWT 10 10 10 42 42 42 53 53 53 56 56 56 Outside Sensors Outside Temperature Sensor Outside Solar Sensor Wind Influence Sensor DOT DOS DOW 11 11 11 43 43 43 53 53 53 56 56 - Remote Adjustment Remote Setting Unit RPW 11 43 53 - Cast Iron Bodies, Screwed, Short Stroke VSBT 17 67 72 - Cast Steel Bodies, Flanged ” ” ” ” (Low Temperature) ” ” (High Temperature) Balanced Valves, Flanged SS-AA, DS-AA SS-AACP DS-AACP SS-AACP VBS, VBG 17 18 18 18 18 67 67 67 67 68 72 72 72 72 72 - 2-port Butterfly Valves Cast Iron Bodies, Flanged VFG 18 68 72 - 3-port Valves (plug & seat) Cast Iron Bodies, Screwed ” Flanged VMB, VMBT VMB.F, VMS, 3V-SA, 3V-GA 19 19 67, 68 67, 68 72 72 - Cast Iron Bodies, Screwed, Short Stroke VMBT 19 67 72 - Cast Steel Bodies, Flanged ” ” (Low Temperature) ” ” (High Temperature) 3V-AA 3V-AACP 3V-AACP 19 20 20 69 69 69 72 72 72 - Linear Drives Pulsed and On/off (100N) MVA 21 70 72 - Pulsed and Proportional Actuators ” ” ” ” ” ” ” ” (200N) (200N) (450N) (1200N) (700N & 1500N) MVT44 MVT56 MVB SH MVL 21 21 21 21 21 70 70 70 70 71 72 72 72 72 72 - Rotary Drives ” (10Nm) (6, 20 & 30Nm) ST MDL 21 21 71 71 72 72 - PRICE SUMMARY Alphanumeric List, Controlli – 23 - - - VALVE SIZING INFORMATION – - 73, 74 72 - SWITCHES & Duct Thermostats, Pressure & Air Velocity Switches THERMOSTATS Air Temperature Thermostats Universal Differential and Universal Pressure Switches Air Flow Switch Air Differential Pressure Switch Product Selection Product Compatibility Obsolete Products TDR, TDC SPA SFA SPA 11 11 11 11 44 44 44 44 - - Pipe Thermostats and Flow Switches Water Flow Switch Water Immersion Thermostat Water Immersion Thermostats (manual reset) SFW TWK TWL, TWM 11 11 11 44 44 44 - - Pipe Temperature Switch Strap-on Pipe Thermostat TSM 11 45 - - Outside and Pipe Frost Thermostats Air Temperature Thermostats TCL 11 45 - - EPT 11 45 - 57 Zone Valve Actuators Zone Valve Actuators (0-10V) Zonemaster Actuators (24V) Zone Valve Actuators (ON/OFF) Electro-thermic Actuators AVE AVU AY AVX, AVM 12 12 12 12 46 46 46 49 54 54 - 58 - Mid Size Valve/actuators Valve/actuator (0...10V) Valve Actuators (Pulsed) AVUE AVUX, AVUM 12 12 46 46 54 54 58 58 Rotary Actuators Modulating and Two-position Light Duty Actuators Rotary Actuators Spring Return Actuator RM, XRM ARX, ARE, ARM RXS, RES, RMS 12 12, 13 13 47 47 47 54 54 54 58 57, 58 - Linear Actuators Self Stroking Intelligent Linear Actuator ‘AL’ Linear Actuators ‘AL-S’ Spring Return Actuators ALi ALX, ALE, ALM ALXS, ALES, ALMS 12 12 12 48 48 48 54 54 54 57 57 57 Small Valves (2, 3 and 4-port) Zone Valves Unit Valves Zone Valves Electro-thermic Valves Bonsai Valves ZY VEU, MEU, FEU ZVX VEX, MEX, FEX BFB 14, 15 14-16 15 14-16 8 49 49 49 49 31 54 - 58 58, 61 58 - 2-port Valves Seat Valves Seat Valves VZX VZ, VZF, VSF 14 14 50 50 54 58 59, 60 3-port Valves Rotary Valves Rotary Valves Seat Valves Seat Valves MB, MBF MBX MZX MZ, MZF, MJF 15 15 15 15 50 50 50 51 54 54 54 59, 61 61 Satchwell Actuators to Satchwell & Third Party Valves Linkage Kits LK, LNK 15 51 - - TRANSFORMERS TR 16 51 - - SPARES – 16 52 - - TRANSDUCERS Transducer Electro Pneumatic Transducer ACTUATORS VALVES LINKAGE KITS Range PRICE SUMMARY Alphanumeric List, Satchwell and Drayton – 22 - - - VALVE SIZING INFORMATION – 62, 63 - - - SENSOR RESISTANCE CHARTS – 64 - - - 4 Price List Product Selection Product Compatibility Obsolete Products VST VSZ 17 17 66 66 72 72 - 3-port Valves (fan-coil) Fan Coil Bodies, Threaded ” ” (for Electro-thermal) VMT VMZ 19 19 66 66 72 72 - 4-port Valves (fan-coil) Fan Coil Bodies, Threaded ” ” (for Electro-thermal) VTT VTZ 20 20 66 66 72 72 - 2-port Valves (plug & seat) Cast Iron Bodies, Screwed ” Flanged VSB, VSBT VSB.F, VSG, SS-GA, VSS 17 17 66, 67 67, 68 72 72 - SMALL VALVES 2-port Valves (fan-coil) Fan Coil Bodies, Threaded ” ” (for Electro-thermal) VALVES ACTUATORS Spares for Actuators, Controllers, Sensors and Valves Code Description 5 PRICE SUMMARY PRICE SUMMARY SATCHWELL & DRAYTON PRODUCTS - ALPHANUMERIC PRICE LIST Code List Price 04-03-109 . . . . . . . . . . . .83.00 0477-9-241 . . . . . . . . . .160.00 0561-9-220 . . . . . . . . . . .39.00 0561-9-260 . . . . . . . . . .110.00 0561-9-261 . . . . . . . . . .225.00 0563-9-231 . . . . . . . . . . .39.00 0579-1-360 . . . . . . . . . .360.00 0588-9-210 . . . . . . . . . . .39.00 0617-9-410 . . . . . . . . . .130.00 0617-9-411 . . . . . . . . . .148.00 0617-9-412 . . . . . . . . . .163.00 0617-9-413 . . . . . . . . . .163.00 0618-9-210 . . . . . . . . . . .58.00 0618-9-510 . . . . . . . . . .225.00 0618-9-511 . . . . . . . . . .238.00 0618-9-512 . . . . . . . . . .238.00 0623-9-201 . . . . . . . . . . .26.00 0626-9-203 . . . . . . . . . . .82.00 0626-9-204 . . . . . . . . . . .50.00 0626-9-310 . . . . . . . . . .124.00 0626-9-311 . . . . . . . . . .155.00 0626-9-312 . . . . . . . . . . .22.00 0626-9-313 . . . . . . . . . . .20.00 0667-9-201 . . . . . . . . . .112.00 0823-2-801 . . . . . . . . . . .18.00 0837-1-203 . . . . . . . . . . .44.00 0837-1-352 . . . . . . . . . . .18.00 0841-1-201 . . . . . . . . . . .72.00 0841-2-201 . . . . . . . . . . .72.00 0851-2-401 . . . . . . . . . . .22.00 0862-7-702 . . . . . . . . . . . .8.00 0866-1-405 . . . . . . . . . . .27.00 A701 . . . . . . . . . . . . . . . .52.00 A702 . . . . . . . . . . . . . . . .71.00 A703 . . . . . . . . . . . . . . .106.00 A704 . . . . . . . . . . . . . . . .76.00 A705 . . . . . . . . . . . . . . .114.00 AD-8961-220 . . . . . . . . .23.00 AD-8969-202 . . . . . . . . .20.00 ALA1211 . . . . . . . . . . . . .36.00 ALA1751 . . . . . . . . . . . . .51.00 ALE1302 . . . . . . . . . . . .760.00 ALE1352 . . . . . . . . . . . .740.00 ALES1302 . . . . . . . . . . .899.00 ALES1352 . . . . . . . . . . .899.00 ALI1576 . . . . . . . . . . . .610.00 ALI1577 . . . . . . . . . . . .650.00 ALI1676 . . . . . . . . . . . .530.00 ALI1677 . . . . . . . . . . . .615.00 ALM1601 . . . . . . . . . . .479.00 ALMS1601 . . . . . . . . . .769.00 ALMS1651 . . . . . . . . . .769.00 ALX1201 . . . . . . . . . . . .439.00 ALX1251 . . . . . . . . . . . .399.00 ALXS1201 . . . . . . . . . . .769.00 ALXS1251 . . . . . . . . . . .769.00 AM-135 . . . . . . . . . . . . .13.00 ARE2302 . . . . . . . . . . . .179.00 ARE2303 . . . . . . . . . . . .185.00 ARE2304 . . . . . . . . . . . .219.00 ARE2352 . . . . . . . . . . . .149.00 ARE2354 . . . . . . . . . . . .179.00 ARE2355 . . . . . . . . . . . .175.00 ARM2606 . . . . . . . . . . .135.00 ARM2607 . . . . . . . . . . .165.00 ARM2656 . . . . . . . . . . .105.00 ARM2657 . . . . . . . . . . .135.00 ARX2202 . . . . . . . . . . . .129.00 ARX2203 . . . . . . . . . . . .159.00 ARX2252 . . . . . . . . . . . .105.00 ARX2253 . . . . . . . . . . . .135.00 AVA1752 . . . . . . . . . . . . .44.00 AVE0001 . . . . . . . . . . . .145.00 AVE0002 . . . . . . . . . . . .155.00 AVM7301 . . . . . . . . . . . .55.00 AVM7351 . . . . . . . . . . . .55.00 AVU2201 . . . . . . . . . . . .83.00 AVUE4304 . . . . . . . . . . .206.00 AVUE4354 . . . . . . . . . . .215.00 AVUM4601 . . . . . . . . . .196.00 AVUX4202 . . . . . . . . . .181.00 AVX7201 . . . . . . . . . . . . .55.00 AVX7251 . . . . . . . . . . . . .55.00 AY1201 . . . . . . . . . . . . . .61.00 AY1251 . . . . . . . . . . . . . .61.00 AY1301 . . . . . . . . . . . . . .61.00 Code List Price AY1351 . . . . . . . . . . . . . .61.00 BCA1601 . . . . . . . . . . . . .49.00 BCA1602 . . . . . . . . . . . . .20.00 BCA9201 . . . . . . . . . . . . .49.00 BCA9202 . . . . . . . . . . . . .39.00 BFB1500 . . . . . . . . . . . . .98.00 BFB1501 . . . . . . . . . . . . .98.00 BFB1506 . . . . . . . . . . . . .92.00 BFB1510 . . . . . . . . . . . . .92.00 BFB1516 . . . . . . . . . . . . .92.00 BFB1520 . . . . . . . . . . . . .92.00 BFB1525 . . . . . . . . . . . . .92.00 BRC-41N-100 . . . . . . . .295.00 BRC-41N-101 . . . . . . . .295.00 BRC-41N-500 . . . . . . . .195.00 BRC-41N-501 . . . . . . . .185.00 BRC-51N-100 . . . . . . . .295.00 BRC-51N-101 . . . . . . . .295.00 BRC-51N-500 . . . . . . . .195.00 BRC-51N-501 . . . . . . . .185.00 BSA1501 . . . . . . . . . . . . .29.00 CSC5252 . . . . . . . . . . . .525.00 CSC5352 . . . . . . . . . . . .550.00 CSM-CORE . . . . . . . . . .250.00 CXR5805 . . . . . . . . . . . .600.00 CXT5605 . . . . . . . . . . . .520.00 CZT5305 . . . . . . . . . . . .650.00 CZU4201 . . . . . . . . . . . .115.00 DC1100 . . . . . . . . . . . . .750.00 DC1100C . . . . . . . . . .1,200.00 DC2100 . . . . . . . . . . . . .299.00 DC2100H . . . . . . . . . .2,250.00 DDC2601 . . . . . . . . . . .120.00 DDCO2602 . . . . . . . . . .963.00 DDH7602 . . . . . . . . . . .356.00 DDH7603 . . . . . . . . . . .276.00 DDP3601 . . . . . . . . . . . .21.00 DDP5601 . . . . . . . . . . .366.00 DDP5610 . . . . . . . . . . .366.00 DDP6601 . . . . . . . . . . .398.00 DDP6610 . . . . . . . . . . .398.00 DDT0001 . . . . . . . . . . . .70.00 DDTH7612 . . . . . . . . . .367.00 DDTH7613 . . . . . . . . . .318.00 DDU0001 . . . . . . . . . . . .20.00 DDU1803 . . . . . . . . . . . .28.00 DDV1201 . . . . . . . . . . .318.00 DOS0002 . . . . . . . . . . . .77.00 DOT0002 . . . . . . . . . . . .70.00 DOW2701 . . . . . . . . . . .276.00 DR3253 . . . . . . . . . . . . . .54.00 DRCO2702 . . . . . . . . . .816.00 DRH7702 . . . . . . . . . . .318.00 DRH7703 . . . . . . . . . . .297.00 DRT3451 . . . . . . . . . . . . .50.00 DRT3453 . . . . . . . . . . . . .52.00 DRT3651 . . . . . . . . . . . . .54.00 DRT3652 . . . . . . . . . . . . .79.00 DRT3801 . . . . . . . . . . . . .85.00 DRT3851 . . . . . . . . . . . . .98.00 DRT4453 . . . . . . . . . . . . .58.00 DRTE2201 . . . . . . . . . . .128.00 DRTE2801 . . . . . . . . . . .185.00 DRTE2851 . . . . . . . . . . .219.00 DRTH7712 . . . . . . . . . .333.00 DRTH7713 . . . . . . . . . .308.00 DRTH8731 . . . . . . . . .1,130.00 DST0001 . . . . . . . . . . . . .64.00 DU4301 . . . . . . . . . . . . .81.00 DUS4302 . . . . . . . . . . . .90.00 DUSF4351 . . . . . . . . . . .149.00 DUSF4352 . . . . . . . . . . .149.00 DWA0001 . . . . . . . . . . . .30.00 DWA0002 . . . . . . . . . . . .73.00 DWA0003 . . . . . . . . . . . .57.00 DWA0004 . . . . . . . . . . . .79.00 DWA0005 . . . . . . . . . . . .22.00 DWT0001 . . . . . . . . . . . .61.00 DWT0002 . . . . . . . . . . . .83.00 EPT7401 . . . . . . . . . . . .330.00 FEU5626 . . . . . . . . . . . . .80.00 FEU5627 . . . . . . . . . . . . .80.00 FEU6414 . . . . . . . . . . . . .52.00 FEU6415 . . . . . . . . . . . . .52.00 Code List Price FEU6416 . . . . . . . . . . . . .52.00 FEU6451 . . . . . . . . . . . . .48.00 FEU6452 . . . . . . . . . . . . .48.00 FEU6454 . . . . . . . . . . . . .48.00 FEX7401 . . . . . . . . . . . . .34.00 FLS1502 . . . . . . . . . . . .699.00 HDS9102 . . . . . . . . . . . .134.00 HDS9103 . . . . . . . . . . . .101.00 HDS9201 . . . . . . . . . . . .268.00 HDS9202 . . . . . . . . . . . .206.00 IAC2602 . . . . . . . . . . . . .75.00 IAC420-F . . . . . . . . . . . .599.00 IAC420-P . . . . . . . . . . . .625.00 IAC600-B . . . . . . . . . .1,200.00 IAC-TS . . . . . . . . . . . . . .830.00 KMC3201 . . . . . . . . . . .550.00 LIB-4-485 . . . . . . . . . . .189.00 LK2407 . . . . . . . . . . . . . .58.00 LK2408 . . . . . . . . . . . . . . .4.00 LK2701 . . . . . . . . . . . . . .44.00 LK2702 . . . . . . . . . . . . . .39.00 LK2703 . . . . . . . . . . . . . .49.00 LNK1402 . . . . . . . . . . . . .17.00 LNKFS01 . . . . . . . . . . . .109.00 LNKFS02 . . . . . . . . . . . .109.00 LNKHW01 . . . . . . . . . . . .44.00 LNKHY01 . . . . . . . . . . .109.00 LNKHY02 . . . . . . . . . . .109.00 LNKIN01 . . . . . . . . . . . . .27.00 LNKLS01 . . . . . . . . . . . . .44.00 LON-TERM1 . . . . . . . . . .35.00 LON-TERM2 . . . . . . . . . .35.00 MB1402 . . . . . . . . . . . .120.00 MB1452 . . . . . . . . . . . .126.00 MB1502 . . . . . . . . . . . .142.00 MB1552 . . . . . . . . . . . .200.00 MB1602 . . . . . . . . . . . .244.00 MB1652 . . . . . . . . . . . .282.00 MBF4732 . . . . . . . . . . .411.00 MBF4782 . . . . . . . . . . .488.00 MBF4857 . . . . . . . . . . .505.00 MBX4401 . . . . . . . . . . . .99.00 MBX4451 . . . . . . . . . . .106.00 MBX4501 . . . . . . . . . . .111.00 MBX4551 . . . . . . . . . . .116.00 MBX4601 . . . . . . . . . . .128.00 MBX4651 . . . . . . . . . . .176.00 MEU4422 . . . . . . . . . . . .71.00 MEU4423 . . . . . . . . . . . .71.00 MEU4425 . . . . . . . . . . . .71.00 MEU4626 . . . . . . . . . . .116.00 MEU4627 . . . . . . . . . . .116.00 MEX7301 . . . . . . . . . . . .28.00 MIU4252 . . . . . . . . . . . .599.00 MJF3426 . . . . . . . . . . . .351.00 MJF3427 . . . . . . . . . . . .351.00 MJF3476 . . . . . . . . . . . .409.00 MJF3526 . . . . . . . . . . . .457.00 MJF3576 . . . . . . . . . . . .549.00 MJF3626 . . . . . . . . . . . .609.00 MJF3676 . . . . . . . . . . . .651.00 MMC4601 . . . . . . . . . . .799.00 MMC4701 . . . . . . . . . . .799.00 MNA-C . . . . . . . . . . . . . .89.00 MNA-FLO-1 . . . . . . . . . .41.00 MNA-R10 . . . . . . . . . . .750.00 MN-DK . . . . . . . . . . . . . .89.00 MN-ETH . . . . . . . . . . . .399.00 MNL-10RF2 . . . . . . . . . .425.00 MNL-10RH2 . . . . . . . . .425.00 MNL-10RR2 . . . . . . . . .425.00 MNL-10RS1 . . . . . . . . . .425.00 MNL-10RS2 . . . . . . . . . .425.00 MNL-11RF2 . . . . . . . . . .395.00 MNL-13RF2 . . . . . . . . . .425.00 MNL-15RF2 . . . . . . . . . .425.00 MNL-15RH2 . . . . . . . . .425.00 MNL-15RR2 . . . . . . . . .425.00 MNL-15RS1 . . . . . . . . . .425.00 MNL-15RS2 . . . . . . . . . .425.00 MNL-20RF2 . . . . . . . . . .555.00 MNL-20RH2 . . . . . . . . .555.00 MNL-20RR2 . . . . . . . . .555.00 MNL-20RS1 . . . . . . . . . .555.00 MNL-20RS2 . . . . . . . . . .555.00 MNL-5RF2 . . . . . . . . . . .295.00 List prices are quoted in UK Sterling (£) CONTROLLI VALVES AND ACTUATORS - ALPHANUMERIC PRICE LIST Code List Price MNL-5RH2 . . . . . . . . . .295.00 MNL-5RR2 . . . . . . . . . .295.00 MNL-5RS1 . . . . . . . . . . .295.00 MNL-5RS2 . . . . . . . . . . .295.00 MNL-C . . . . . . . . . . . . .139.00 MN-LCD-100 . . . . . . . . .375.00 MN-LCDP-100 . . . . . . . .375.00 MNL-FLOW-BAL . . . . . .204.00 MNL-TS-100 . . . . . . . . .894.00 MNL-TSP-100 . . . . . . . .990.00 MNL-V1RV2 . . . . . . . . .395.00 MNL-V2RV2 . . . . . . . . .420.00 MNL-V3RV2 . . . . . . . . .420.00 MN-MER . . . . . . . . . .2,500.00 MN-MER-OUT . . . . . . . .850.00 MNN-30-100 . . . . . . . . .495.00 MNN-44-100 . . . . . . . . .475.00 MNN-50-100 . . . . . . . . .695.00 MNN-62-100 . . . . . . .1,050.00 MNN-COM . . . . . . . . . . .60.00 MNN-MI-100 . . . . . . . .425.00 MNN-RTC . . . . . . . . . . . .65.00 MNN-TS-100 . . . . . . . . .695.00 MNN-TSP-100 . . . . . . . .780.00 MN-S1 . . . . . . . . . . . . . .89.00 MN-S2 . . . . . . . . . . . . . .99.00 MN-S3 . . . . . . . . . . . . .109.00 MN-S4 . . . . . . . . . . . . .125.00 MN-S4-FCS . . . . . . . . . .120.00 MN-S5 . . . . . . . . . . . . .155.00 MN-TK . . . . . . . . . . . . . .55.00 MN-VSCORE . . . . . . . . .500.00 MN-VSLON . . . . . . . . . .350.00 MN-VW100-UK . . . . .1,400.00 MN-VW10K-UK . . . . .5,500.00 MN-VW2K-UK . . . . . .4,000.00 MN-VW500-UK . . . . .2,800.00 MN-VW60K-UK . . . .10,000.00 MN-VWIO-MOD . . . . .1,600.00 MN-VWIO-NCP . . . . .1,100.00 MN-VWION-NCP . . . .1,100.00 MN-VWION-SNP . . . .1,100.00 MN-VWIO-SNP . . . . . .1,100.00 MN-VWP100-UK . . . .4,000.00 MN-VWP10K-UK . . . .8,200.00 MN-VWP2K-UK . . . . .7,000.00 MN-VWP500-UK . . . .5,500.00 MN-VWP60K-UK . . .13,000.00 MZ3402 . . . . . . . . . . . .174.00 MZ3452 . . . . . . . . . . . .188.00 MZ3501 . . . . . . . . . . . .215.00 MZ3551 . . . . . . . . . . . .232.00 MZ3601 . . . . . . . . . . . .337.00 MZ3651 . . . . . . . . . . . .455.00 MZF3729 . . . . . . . . . . .865.00 MZF3779 . . . . . . . . . .1,138.00 MZF3854 . . . . . . . . . .1,415.00 MZF3904 . . . . . . . . . .1,688.00 MZF3958 . . . . . . . . . .2,097.00 MZX4402 . . . . . . . . . . .126.00 MZX4452 . . . . . . . . . . .137.00 MZX4501 . . . . . . . . . . .155.00 MZX4551 . . . . . . . . . . .185.00 MZX4601 . . . . . . . . . . .203.00 MZX4651 . . . . . . . . . . .245.00 RB1 . . . . . . . . . . . . . . . . .64.00 RB2 . . . . . . . . . . . . . . . . .64.00 RES7354 . . . . . . . . . . . .374.00 RES7355 . . . . . . . . . . . .185.00 RM3601 . . . . . . . . . . . .379.00 RMS7654 . . . . . . . . . . .361.00 RMS7655 . . . . . . . . . . .387.00 RMS7656 . . . . . . . . . . .237.00 RMS7657 . . . . . . . . . . .237.00 RPW4425 . . . . . . . . . . .169.00 RXS7254 . . . . . . . . . . . .361.00 RXS7255 . . . . . . . . . . . .387.00 RXS7256 . . . . . . . . . . . .232.00 RXS7257 . . . . . . . . . . . .258.00 SFA1451 . . . . . . . . . . . . .83.00 SFW1251 . . . . . . . . . . . .98.00 SPA1401 . . . . . . . . . . . . .46.00 SPA1402 . . . . . . . . . . . . .46.00 SPA1501 . . . . . . . . . . . .140.00 SPA1502 . . . . . . . . . . . .140.00 SPA1503 . . . . . . . . . . . .175.00 Code List Price SPA1504 . . . . . . . . . . . .175.00 SPA1505 . . . . . . . . . . . . .73.00 SPA1506 . . . . . . . . . . . . .73.00 SVT4201 . . . . . . . . . . . .499.00 SVT4251 . . . . . . . . . . . .549.00 TCL1601 . . . . . . . . . . . . .65.00 TCL1602 . . . . . . . . . . . . .62.00 TCL1603 . . . . . . . . . . . . .62.00 TDC2202 . . . . . . . . . . . . .57.00 TDR2201 . . . . . . . . . . . . .54.00 TR1 . . . . . . . . . . . . . . . . .52.00 TR2 . . . . . . . . . . . . . . . . .71.00 TR3 . . . . . . . . . . . . . . . . .96.00 TR4 . . . . . . . . . . . . . . . .132.00 TR5 . . . . . . . . . . . . . . . .214.00 TSM2501 . . . . . . . . . . . .26.00 TWK2301 . . . . . . . . . . . .57.00 TWL2302 . . . . . . . . . . . .52.00 TWM2401 . . . . . . . . . . . .84.00 URC-41N-100 . . . . . . . .195.00 URC-41N-101 . . . . . . . .195.00 URC-41N-102 . . . . . . . .195.00 URC-41N-103 . . . . . . . .195.00 URC-51N-100 . . . . . . . .210.00 URC-51N-101 . . . . . . . .210.00 URC-51N-102 . . . . . . . .210.00 URC-51N-103 . . . . . . . .220.00 URC-IR-100 . . . . . . . . . .450.00 URC-SET-100 . . . . . . . . .120.00 VEU4414 . . . . . . . . . . . . .71.00 VEU4415 . . . . . . . . . . . . .71.00 VEU4416 . . . . . . . . . . . . .71.00 VEU4626 . . . . . . . . . . . .116.00 VEX7201 . . . . . . . . . . . . .27.00 VSF1476 . . . . . . . . . . . .462.00 VSF1526 . . . . . . . . . . . .529.00 VSF1576 . . . . . . . . . . . .611.00 VSF1626 . . . . . . . . . . . .741.00 VSF1676 . . . . . . . . . . . .801.00 VSF2426 . . . . . . . . . . . .455.00 VSF2427 . . . . . . . . . . . .455.00 VSF2428 . . . . . . . . . . . .455.00 VSF2429 . . . . . . . . . . . .455.00 VSF2430 . . . . . . . . . . . .455.00 VV-LITE . . . . . . . . . . .1,000.00 VV-LITE-TO-STD . . . . .1,100.00 VV-STANDARD . . . . . .2,000.00 VZ1401 . . . . . . . . . . . . .174.00 VZ1402 . . . . . . . . . . . . .174.00 VZ1403 . . . . . . . . . . . . .174.00 VZ1404 . . . . . . . . . . . . .174.00 VZ1451 . . . . . . . . . . . . .188.00 VZ2501 . . . . . . . . . . . . .215.00 VZ2551 . . . . . . . . . . . . .232.00 VZ2601 . . . . . . . . . . . . .337.00 VZ2651 . . . . . . . . . . . . .560.00 VZF1727 . . . . . . . . . . . .783.00 VZF1777 . . . . . . . . . . .1,057.00 VZF1852 . . . . . . . . . . .1,468.00 VZF1902 . . . . . . . . . . .1,605.00 VZF1954 . . . . . . . . . . .2,015.00 VZX4404 . . . . . . . . . . . .114.00 VZX4451 . . . . . . . . . . . .124.00 VZX4501 . . . . . . . . . . . .142.00 VZX4551 . . . . . . . . . . . .169.00 VZX4601 . . . . . . . . . . . .190.00 VZX4651 . . . . . . . . . . . .231.00 WP-TECH-32 . . . . . . . .3,000.00 WP-TECH-CD-E-32 . . . . .250.00 XRM3201 . . . . . . . . . . .379.00 ZVX4201 . . . . . . . . . . . . .61.00 ZVX4202 . . . . . . . . . . . . .66.00 ZVX4203 . . . . . . . . . . . . .72.00 ZVX4301 . . . . . . . . . . . . .48.00 ZVX4302 . . . . . . . . . . . . .64.00 ZVX4303 . . . . . . . . . . . . .70.00 ZVX4401 . . . . . . . . . . . . .81.00 ZY1201 . . . . . . . . . . . . . .33.00 ZY1202 . . . . . . . . . . . . . .33.00 ZY1203 . . . . . . . . . . . . . .33.00 ZY1204 . . . . . . . . . . . . . .37.00 ZY1205 . . . . . . . . . . . . . .37.00 ZY1206 . . . . . . . . . . . . . .37.00 ZY1301 . . . . . . . . . . . . . .33.00 ZY1302 . . . . . . . . . . . . . .33.00 ZY1303 . . . . . . . . . . . . . .33.00 ZY1304 . . . . . . . . . . . . . .37.00 ZY1305 . . . . . . . . . . . . . .37.00 ZY1306 . . . . . . . . . . . . . .37.00 Code List Price 244 . . . . . . . . . . . . . . . .185.00 245 . . . . . . . . . . . . . . . .195.00 246 . . . . . . . . . . . . . . . .195.00 51938 . . . . . . . . . . . . . . .32.00 52554 . . . . . . . . . . . . . .£27.00 52980 . . . . . . . . . . . . . . .47.00 260915 . . . . . . . . . . . . . .47.00 3V-AA100 . . . . . . . . . .4,716.00 3V-AA125 . . . . . . . . . .6,407.00 3VAA25 . . . . . . . . . . .1,346.00 3V-AA25I . . . . . . . . . .1,346.00 3V-AA25R . . . . . . . . .1,346.00 3V-AA32 . . . . . . . . . .1,609.00 3V-AA40 . . . . . . . . . .1,859.00 3V-AA50 . . . . . . . . . .2,202.00 3V-AA65 . . . . . . . . . .2,691.00 3V-AA80 . . . . . . . . . .3,179.00 3V-AACP100 . . . . . . . .5,811.00 3V-AACP100B . . . . . .5,811.00 3V-AACP125 . . . . . . . .7,826.00 3V-AACP125B . . . . . .7,826.00 3V-AACP25 . . . . . . . .1,951.00 3V-AACP25B . . . . . . .1,951.00 3V-AACP25I . . . . . . . .1,951.00 3V-AACP25IB . . . . . . .1,951.00 3V-AACP25R . . . . . . .1,951.00 3V-AACP25RB . . . . . .1,951.00 3V-AACP32 . . . . . . . .2,293.00 3V-AACP32B . . . . . . .2,293.00 3V-AACP40 . . . . . . . .2,560.00 3V-AACP40B . . . . . . .2,557.00 3V-AACP50 . . . . . . . .2,903.00 3V-AACP50B . . . . . . .2,903.00 3V-AACP65 . . . . . . . .3,446.00 3V-AACP65B . . . . . . .3,446.00 3V-AACP80 . . . . . . . .4,098.00 3V-AACP80B . . . . . . .4,098.00 3V-GA100 . . . . . . . . .2,631.00 3V-GA125 . . . . . . . . .4,292.00 3V-SA80 . . . . . . . . . . .1,795.00 AF22 . . . . . . . . . . . . . . .159.00 AG21 . . . . . . . . . . . . . . .27.00 AG31 . . . . . . . . . . . . . . .27.00 D36 . . . . . . . . . . . . . . . .47.00 D5 . . . . . . . . . . . . . . . . .47.00 DMVL . . . . . . . . . . . . . . .73.00 DS-AA100 . . . . . . . . .5,200.00 DS-AA125 . . . . . . . . .6,789.00 DS-AA150 . . . . . . . . .8,967.00 DS-AA32 . . . . . . . . . .1,796.00 DS-AA40 . . . . . . . . . .2,129.00 DS-AA50 . . . . . . . . . .2,524.00 DS-AA65 . . . . . . . . . .2,921.00 DS-AA80 . . . . . . . . . .3,586.00 DS-AACP100 . . . . . . .6,690.00 DS-AACP100B . . . . . .6,690.00 DS-AACP125 . . . . . . .8,469.00 DS-AACP125B . . . . . .8,469.00 DS-AACP150 . . . . . .10,891.00 DS-AACP150B . . . . .10,891.00 DS-AACP32 . . . . . . . .2,550.00 DS-AACP32B . . . . . . .2,550.00 DS-AACP32R . . . . . . .2,550.00 DS-AACP32RB . . . . . .2,550.00 DS-AACP40 . . . . . . . .2,875.00 DS-AACP40B . . . . . . .2,875.00 DS-AACP50 . . . . . . . .3,358.00 DS-AACP50B . . . . . . .3,358.00 DS-AACP65 . . . . . . . .3,930.00 DS-AACP65B . . . . . . .3,930.00 DS-AACP80 . . . . . . . .4,695.00 DS-AACP80B . . . . . . .4,695.00 MDL22 . . . . . . . . . . . . .490.00 MDL24 . . . . . . . . . . . . .502.00 MDL26 . . . . . . . . . . . . .541.00 MDL42 . . . . . . . . . . . . .490.00 MDL44 . . . . . . . . . . . . .502.00 MDL46 . . . . . . . . . . . . .544.00 MDL52 . . . . . . . . . . . . .599.00 MDL54 . . . . . . . . . . . . .685.00 Code List Price MDL56 . . . . . . . . . . . . .649.00 MVA21 . . . . . . . . . . . . . .30.00 MVA23 . . . . . . . . . . . . . .28.00 MVA41 . . . . . . . . . . . . . .30.00 MVA43 . . . . . . . . . . . . . .28.00 MVB26 . . . . . . . . . . . . .256.00 MVB46 . . . . . . . . . . . . .237.00 MVB52 . . . . . . . . . . . . .314.00 MVB56 . . . . . . . . . . . . .307.00 MVBC . . . . . . . . . . . . . . .32.00 MVBHT . . . . . . . . . . . . . .19.00 MVBPA2 . . . . . . . . . . . . .57.00 MVL26 . . . . . . . . . . . . .603.00 MVL46 . . . . . . . . . . . . .603.00 MVL46A . . . . . . . . . . . .703.00 MVL46C . . . . . . . . . . . .703.00 MVL56 . . . . . . . . . . . . .694.00 MVL56A . . . . . . . . . . . .832.00 MVL56C . . . . . . . . . . . .832.00 MVLPA2 . . . . . . . . . . . . .85.00 MVLPA4 . . . . . . . . . . . . .85.00 MVLPA4M . . . . . . . . . . . .85.00 MVT44 . . . . . . . . . . . . . .73.00 MVT56 . . . . . . . . . . . . .132.00 P-1000-1 . . . . . . . . . . . . .85.00 P-140-1 . . . . . . . . . . . . . .85.00 SH222 . . . . . . . . . . . . . .481.00 SH242 . . . . . . . . . . . . . .506.00 SH522 . . . . . . . . . . . . . .593.00 SS-AA15 . . . . . . . . . . . .797.00 SS-AA15R . . . . . . . . . . .797.00 SS-AA20 . . . . . . . . . . . .864.00 SS-AA25 . . . . . . . . . . . .953.00 SS-AA32 . . . . . . . . . . .1,115.49 SS-AA40 . . . . . . . . . . .1,296.00 SS-AA50 . . . . . . . . . . .1,551.00 SS-AA65 . . . . . . . . . . .1,971.00 SS-AA80 . . . . . . . . . . .2,549.00 SS-AACP15 . . . . . . . . .1,298.00 SS-AACP15B . . . . . . . .1,298.00 SS-AACP15R . . . . . . . .1,298.00 SS-AACP15RB . . . . . . .1,298.00 SS-AACP20 . . . . . . . . .1,375.00 SS-AACP20B . . . . . . . .1,375.00 SS-AACP25 . . . . . . . . .1,495.00 SS-AACP25B . . . . . . . .1,496.00 SS-AACP32 . . . . . . . . .1,783.00 SS-AACP32B . . . . . . . .1,782.00 SS-AACP40 . . . . . . . . .1,978.00 SS-AACP40B . . . . . . . .1,978.00 SS-AACP50 . . . . . . . . .2,260.00 SS-AACP50B . . . . . . . .2,260.00 SS-AACP65 . . . . . . . . .2,875.00 SS-AACP65B . . . . . . . .2,875.00 SS-AACP80 . . . . . . . . .3,615.00 SS-AACP80B . . . . . . . .3,615.00 SS-GA100 . . . . . . . . . .1,820.00 SS-GA15 . . . . . . . . . . . .358.00 SS-GA15R . . . . . . . . . . .358.00 SS-GA20 . . . . . . . . . . . .362.00 SS-GA25 . . . . . . . . . . . .381.00 SS-GA32 . . . . . . . . . . . .459.00 SS-GA40 . . . . . . . . . . . .508.00 SS-GA50 . . . . . . . . . . . .729.00 SS-GA65 . . . . . . . . . . . .950.00 SS-GA80 . . . . . . . . . . .1,198.00 ST404 . . . . . . . . . . . . . .373.00 ST405 . . . . . . . . . . . . . .280.00 VBG100 . . . . . . . . . . .1,751.00 VBG125 . . . . . . . . . . .2,208.00 VBG150 . . . . . . . . . . .2,687.00 VBG80 . . . . . . . . . . . .1,364.00 VBS25 . . . . . . . . . . . . . .610.00 VBS251 . . . . . . . . . . . . .610.00 VBS252R . . . . . . . . . . . .610.00 VBS32 . . . . . . . . . . . . . .713.00 VBS40 . . . . . . . . . . . . . .783.00 VBS50 . . . . . . . . . . . .1,104.00 VBS65 . . . . . . . . . . . .1,392.00 VFG10-100 . . . . . . . . . .420.00 VFG10-125 . . . . . . . . . .459.00 Code List Price VFG10-150 . . . . . . . . . .591.00 VFG10-200 . . . . . . . . . .844.00 VFG10-40 . . . . . . . . . . .369.00 VFG10-50 . . . . . . . . . . .366.00 VFG10-65 . . . . . . . . . . .369.00 VFG10-80 . . . . . . . . . . .390.00 VMB1 . . . . . . . . . . . . . .103.00 VMB11 . . . . . . . . . . . . .103.00 VMB11F . . . . . . . . . . . .190.00 VMB15 . . . . . . . . . . . . .103.00 VMB15F . . . . . . . . . . . .190.00 VMB16100 . . . . . . . . . .838.00 VMB16125 . . . . . . . . .1,419.00 VMB16150 . . . . . . . . .1,902.00 VMB1665 . . . . . . . . . . .512.00 VMB1680 . . . . . . . . . . .610.00 VMB1F . . . . . . . . . . . . .190.00 VMB2 . . . . . . . . . . . . . .103.00 VMB2F . . . . . . . . . . . . .190.00 VMB3 . . . . . . . . . . . . . .108.00 VMB3F . . . . . . . . . . . . .199.00 VMB4 . . . . . . . . . . . . . .117.00 VMB4F . . . . . . . . . . . . .210.00 VMB5 . . . . . . . . . . . . . .151.00 VMB5F . . . . . . . . . . . . .235.00 VMB6 . . . . . . . . . . . . . .184.00 VMB6F . . . . . . . . . . . . .259.00 VMB8 . . . . . . . . . . . . . .227.00 VMB8A . . . . . . . . . . . . .227.00 VMB8AF . . . . . . . . . . . .298.00 VMB8F . . . . . . . . . . . . .298.00 VMB9F . . . . . . . . . . . . .564.00 VMBT3 . . . . . . . . . . . . .131.00 VMBT4 . . . . . . . . . . . . .144.00 VMBT5 . . . . . . . . . . . . .163.00 VMBT6 . . . . . . . . . . . . .184.00 VMS25 . . . . . . . . . . . . .704.00 VMS251 . . . . . . . . . . . .704.00 VMS25R . . . . . . . . . . . .704.00 VMS32 . . . . . . . . . . . . .886.00 VMS40 . . . . . . . . . . . . .886.00 VMS50 . . . . . . . . . . . .1,115.00 VMS65 . . . . . . . . . . . .1,390.00 VMT09 . . . . . . . . . . . . . .35.00 VMT1 . . . . . . . . . . . . . . .35.00 VMT10 . . . . . . . . . . . . . .35.00 VMT11 . . . . . . . . . . . . . .35.00 VMT12 . . . . . . . . . . . . . .35.00 VMT13 . . . . . . . . . . . . . .35.00 VMT2 . . . . . . . . . . . . . . .44.00 VMZ09B . . . . . . . . . . . . .35.00 VMZ10B . . . . . . . . . . . . .35.00 VMZ11B . . . . . . . . . . . . .35.00 VMZ12B . . . . . . . . . . . . .35.00 VMZ13B . . . . . . . . . . . . .35.00 VMZ1B . . . . . . . . . . . . . .35.00 VMZ2B . . . . . . . . . . . . . .44.00 VSB1 . . . . . . . . . . . . . . .103.00 VSB11 . . . . . . . . . . . . . .103.00 VSB11F . . . . . . . . . . . . .168.00 VSB15 . . . . . . . . . . . . . .106.00 VSB15F . . . . . . . . . . . . .173.00 VSB1F . . . . . . . . . . . . . .173.00 VSB2 . . . . . . . . . . . . . . .109.00 VSB2F . . . . . . . . . . . . . .173.00 VSB3 . . . . . . . . . . . . . . .108.00 VSB3F . . . . . . . . . . . . . .182.00 VSB4 . . . . . . . . . . . . . . .117.00 VSB4F . . . . . . . . . . . . . .194.00 VSB5 . . . . . . . . . . . . . . .151.00 VSB5F . . . . . . . . . . . . . .210.00 VSB6 . . . . . . . . . . . . . . .184.00 VSB6F . . . . . . . . . . . . . .236.00 VSB8 . . . . . . . . . . . . . . .228.00 VSB8A . . . . . . . . . . . . . .228.00 VSB8AF . . . . . . . . . . . . .276.00 VSB8F . . . . . . . . . . . . . .276.00 VSB9F . . . . . . . . . . . . . .595.00 VSBT3 . . . . . . . . . . . . . .132.00 VSBT4 . . . . . . . . . . . . . .144.00 VSBT5 . . . . . . . . . . . . . .164.00 List prices are quoted in UK Sterling (£) 22 23 Code List Price VSBT6 . . . . . . . . . . . . . .184.00 VSG100 . . . . . . . . . . . . .886.00 VSG125 . . . . . . . . . . .1,537.00 VSG150 . . . . . . . . . . .2,239.00 VSG65 . . . . . . . . . . . . . .541.00 VSG80 . . . . . . . . . . . . . .681.00 VSS25 . . . . . . . . . . . . . .633.00 VSS251 . . . . . . . . . . . . .633.00 VSS25R . . . . . . . . . . . . .633.00 VSS32 . . . . . . . . . . . . . .835.00 VSS40 . . . . . . . . . . . . . .982.00 VSS50 . . . . . . . . . . . .1,188.00 VSS65 . . . . . . . . . . . .1,495.00 VST09 . . . . . . . . . . . . . . .33.00 VST1 . . . . . . . . . . . . . . . .33.00 VST10 . . . . . . . . . . . . . . .33.00 VST11 . . . . . . . . . . . . . . .33.00 VST12 . . . . . . . . . . . . . . .33.00 VST13 . . . . . . . . . . . . . . .33.00 VST2 . . . . . . . . . . . . . . . .41.00 VST21 . . . . . . . . . . . . . . .41.00 VSZ09B . . . . . . . . . . . . . .33.00 VSZ10B . . . . . . . . . . . . . .33.00 VSZ11B . . . . . . . . . . . . . .33.00 VSZ12B . . . . . . . . . . . . . .33.00 VSZ13B . . . . . . . . . . . . . .33.00 VSZ1B . . . . . . . . . . . . . . .33.00 VSZ21B . . . . . . . . . . . . . .41.00 VSZ2B . . . . . . . . . . . . . . .41.00 VTT09 . . . . . . . . . . . . . . .37.00 VTT1 . . . . . . . . . . . . . . . .37.00 VTT10 . . . . . . . . . . . . . . .37.00 VTT11 . . . . . . . . . . . . . . .37.00 VTT12 . . . . . . . . . . . . . . .37.00 VTT13 . . . . . . . . . . . . . . .37.00 VTT2 . . . . . . . . . . . . . . . .47.00 VTT21 . . . . . . . . . . . . . . .47.00 VTZ09B . . . . . . . . . . . . . .37.00 VTZ10B . . . . . . . . . . . . . .37.00 VTZ11B . . . . . . . . . . . . . .37.00 VTZ12B . . . . . . . . . . . . . .37.00 VTZ13B . . . . . . . . . . . . . .37.00 VTZ1B . . . . . . . . . . . . . . .37.00 VTZ21B . . . . . . . . . . . . . .47.00 VTZ2B . . . . . . . . . . . . . . .47.00 Satchwell MicroNet NOTES PRODUCT SELECTION Software VisiView is a state-of-the-art graphical user interface for MicroNet and Satchnet networking controllers, utilising the latest web technology to give users total visibility of heating, ventilation and air conditioning installations in their buildings. VisiView VV-LITE VV-STANDARD VV-LITE-TO-STD VisiView, provides fully flexible access to system parameters, status and performance via users’ own PC browsers. Up to three users can log on concurrently. Installed on a simple plug-and-play basis, VisiView uses industry-standard Windows XP Pro and Microsoft Explorer software. FEATURES (cont) • Graphical User Interface (GUI) using Internet Explorer • Scalable Vector Graphics (SVG) enable dynamically generated, high-quality graphics from real-time data • Comprehensive library of SVG objects provides graphical controls for a wide range of schemes • Provides visualisation of live schemes from any location connected to the Internet/Intranet • Resolution independent graphics rendering • End user requires Web browser only • Alarms: value and state based with alarms transmitted by email • Only authorised users can log on to VisiView projects • Open architecture: can stream third-party data • Live information, streamed direct to the browser • User interface available in multiple languages • Uses VisiSat Points List as basis for project design • Any number of users (clients) possible, with up to 3 concurrent users • MicroNet data source provided as standard • Administrator configuration of users, projects and communications • Supports MicroNet, IAC and MMC controllers • Security/Access: access rights can extend to individual rights on each Point of data • Logging: both historical and live-trend display MicroNet View is a software platform that provides an intuitive, graphical interface for network-level supervisory and control functions. MicroNet View works on any of the MicroNet network options, LONWORKS® FTT-10 Free Topology, NCP (Native Communications Protocol), and ARCNET, and works with the MicroNet family. MicroNet View supports also Satchnet range products such as IAC controllers and third party products such as chillers, boilers and access control systems. FEATURES MicroNet View • Real-time data on active, multi-media graphical displays • Provides intuitive operation via customised control panels • Support for DDE, and fast DDE standards • Supports the use of bitmaps, photos, and other graphic formats when designing the network reporting display • Comprehensive logging and alarm management utilities Description Type MN-VW100-UK MN-VW500-UK MN-VW2K-UK MN-VW10K-UK MN-VW60K-UK MicroNet View ” ” ” ” 100 tag, English version 500 tag, English version 2,000 tag, English version 10,000 tag, English version 60,000 tag, English version MN-VWIO-NCP MN-VWIO-SNP MN-VWION-NCP MN-VWION-SNP I/O-servers (dongles) ” ” NCP/ARCNET I/O-server, dongle Satchnet I/O-server, dongle NCP/ARCNET I/O-server, for existing dongle Satchnet I/O-server, for existing dongle MN-VWP100-UK MN-VWP500-UK MN-VWP2K-UK MN-VWP10K-UK MN-VWP60K-UK MicroNet View Pro (development) ” ” ” 100 tag, English version 500 tag, English version 2,000 tag, English version 10,000 tag, English version 60,000 tag, English version Data Sheet 10.201 HARDWARE SPECIFICATIONS See data sheet for minimum hardware requirements. ACCESSORIES ECH-37200 ECH-42100 ECH-42102 ECH-42105 ECH-48222 ECH-73403 ECH-74401 WPA-LON-1 WPA-LON-2 SPI-1111 SPI-1112 MicroNet View Pro • Allows graphics generation and development of the application • Powerful scripting editor for creating and performing system tasks • Use of ActiveX® Controls and Wizards makes the system configuration easy • Allows monitoring and editing of system variables 24 up to 250 points, 2 concurrent clients up to 2000 points, 3 concurrent clients HARDWARE SPECIFICATIONS See data sheet for minimum hardware requirements. FEATURES VisiSat™2 Configuration Tool Type VisiView Lite VisiView Standard VisiView Lite to Standard Upgrade Data Sheet 10.204 VisiView is ideal for smaller sites (and networks of sites) where cost-effective solutions are required. It is particularly effective where maintenance people require remote access via a standard browser, and where ease of installation and engineering is critical. MicroNet View Description This software is a cohesive, flexible, system engineering tool compatible with Microsoft Windows 2000 Professional and Windows XP. It uses Visio 2000 or Visio 2002 32-bit drawing interface for graphic representation of control applications and control objects. With this configuration tool, a designer can customise an application to match specific project requirements then loads the application to a stand alone or networked controller. LNS DDE server edition LPR-10 Router Module TP/FT-10 to TP/FT-10 LPR-12 Router Module TP/FT-10 to TPXF-1250 LPR-15 Router Module TP/XF-1250 to TP/XF-1250 Type 2D DIN Base Plate PCLTA-10/TP-1250 ISA (16-bit) Desktop interface PCLTA-20/FT-10 PCI (32-bit) Desktop interface PC ISA Card (16-bit) to connect PCs to LONWORKS FTT-10 network PCMCIA Card to connect Laptop PCs to LONWORKS FTT-10 network SPI Main Software (with dongle) SPI Main Software (for existing dongle) Description MN-VSCORE MN-VSLON VisiSat 2 ” Type Configuration tool, core software Plug-in option for LON devices Data Sheet 10.202 HARDWARE SPECIFICATIONS See data sheet for minimum hardware requirements. ACCESSORIES LIB-4-485 WPA-LON-1 WPA-LON-2 ECH-33100-10 ECH-37000 ECH-37100 ECH-73403 ECH-74401 FEATURES • Runs under Visio 2000 or Visio 2002 • Compatible with Windows 2000 Professional or Windows xp • Controllers are programmed using graphical objects in "Bubbleland" • Powerful and intuitive configuration of interfaces • Unique mechanism to change LON controller profiles • 'Custom' object creation for standard repeated applications • Configuration report generation • Autogeneration of wiring diagrams • Multiple trends on single page. 25 RS 232/RS 485 Converter to connect PC to NCP network PCISA Card (16-bit) to connect PCs to LONWORKS FTT-10 network PC (PCMCIA) Card to connect Laptop PCs to LONWORKS FTT-10 network LonManager PCC-10 Protocol analyzer LonMaker for Windows Integration Tool Siebe edition LonMaker Credits (1 unit = 1 credit) PCLTA-10/TP-1250 ISA (16-bit) Desktop interface PCLTA-20/FT-10 PCI (32-bit) Desktop interface PRODUCT SELECTION Software Satchwell MicroNet WP Tech is a Windows 2000 compatible program used to create and download control logic applications to MicroNet LONMARK® controllers. The program uses a Visio 32-bit drawing interface for a graphical representation of applications control logic. CSM Tool Description Type WP-TECH-CD-E-32 Workplace Tech CD-Rom WP-TECH-32 Workplace Tech Licence Configuration tool files for LONMARK controllers Software unlock codes and licence Data Sheet – FEATURES/BENEFITS • Easy operation – modify existing pre-engineered applications – engineer a complete custom application – compile and download control logic applications to controllers – examine controller memory usage required by an application • Object-oriented programming environment • Programmable shapes • Visio drawing environment HARDWARE SPECIFICATIONS See data sheet for minimum hardware requirements. ACCESSORIES WPA-LON-1 WPA-LON-2 ECH-33100-10 ECH-37000 ECH-37100 ECH-73403 ECH-74401 Remote Alarm Manager is a powerful software package for routing alarm information to management and service personnel. It integrates seamlessly to Micronet View and includes comprehensive alarm tracking and history. Remote Alarm Manager MN 50 PC ISA Card (16-bit) to connect PCs to LONWORKS FTT-10 network PC (PCMCIA) Card to connect Laptop PCs to LONWORKS FTT-10 network LonManager PCC-10 Protocol analyzer LonMaker for Windows Integration Tool Siebe edition LonMaker Credits (1 unit = 1 credit) PCLTA-10/TP-1250 ISA (16-bit) Desktop interface PCLTA-20/FT-10 PCI (32-bit) Desktop interface Description Programmable Controllers System software, includes 1 output driver Output drivers (see data sheet) HARDWARE SPECIFICATIONS See data sheet for minimum hardware requirements. FEATURES (cont) • Core software includes Web and WAP interfaces • Self-monitoring of system hardware and software • Console for system configuration and full alarm history FEATURES • Alarm information collected automatically from Micronet View • Output drivers to fax, remote printer, Web pages, SMS messaging or E-mail. MN 100, 150 & 200 Programmable controllers The Commissioning, Service and Maintenance Tool (CSM Tool) is an engineering tool used by field engineers to modify (and monitor) a standard MicroNet system, by downloading VisiSat applications to one or more selected bus-du-jour (and LON) controllers and changing the properties of those controllers to suit the local requirements. All controllers supported by VisiSat are supported by the CSM Tool. The CSM Tool is based on VisiSat COM objects which enable communications, downloading of schemes and editing of properties. It is a stand-alone application intended to be run on a laptop connected to a Satchnet (IAC), NCP ARCNET® or LON network via a communications server. There is no need for Microsoft® Visio to be installed on the same computer. The CSM Tool is compatible with Microsoft® Windows® XP Professional and Windows 2000 Professional (Windows XP preferred). Description CSM-CORE CSM Tool Type Commissioning, Service and Maintenance Tool Data Sheet 10.203 HARDWARE SPECIFICATIONS See data sheet for minimum hardware requirements Controllers (LONM FEATURES (cont) • Supports all controllers, network management and display devices supported by VisiSat Controllers with Integral Actuator ) The MNL-11RF2 is an interoperable, LONMARK Compliant Controller. When programmed using WorkPlace Tech Tool it provides control for fan coil applications. The controller conforms to the LONMARK fan coil unit functional profile (8020), for open communication and interoperability with third party LONMARK devices - providing greater freedom in system design. Fan Coil Unit Controller The controller can function in a stand-alone mode or as part of a LONWORKS FTT-10 free topology network. MNL-11RF2 Controller with Fan Coil Profile LONMARK profile Fan Coil Inputs/outputs 3 x universal input (UI) 4 x digital outputs (DO) 1 x 230Vac, 3A relay MNL-13RF2 with Fan Coil Profile Fan Coil 3 x universal input (UI) 4 x digital outputs (DO) 3 x 230Vac, 3A relays Data Sheet – F26886/7 Power supply - 24Vac, 50/60Hz Protection class - IP 20 Mounting - Wall mounted or DIN rail Sensor inputs - MN Sx digital sensor link Universal inputs - 10k resistance, 1kΩ Balco input, 1kΩ Platinum input, 1k resistance, 10kΩ thermistor with 11k shunt resistors, voltage, current, digital input Digital outputs - MN 11: 1 x relay output, 4 x 24Vac triac outputs MN 13: 3 x relay outputs, 4 x 24Vac triac outputs FEATURES • LONTalk® FTT-10 support • LONMARK® fan coil profile 8020 support • Fully programmable using WorkPlace Tech Tool • S-link support • On board LED indication without cover removal • Built-in LON jack, for connection to a LON network ACCESSORIES – see page 28 26 FEATURES • LONMARK compliant, programmable • Capability to function in stand-alone mode or as part of a LONWORKS FTT-10 Free Topology communications network • Proportional (P), Proportional Plus Integral (PI), and Proportional Plus Integral and Derivative (PID) control for cooling and heating • LED indication • Plenum-rated enclosure • Satellite profile allows controller to be used in a broad range of applications Power supply - 20.4...30Vac, 50/60Hz Consumption - 84VA max : 12VA plus DO loads (24Vac each) Surge immunity compliance - ANSI C62.41 (IEEE-587, Category A & B) Protection class - IP 20 Mounting - 35mm DIN rail or panel Sensor inputs - MN Sx digital sensor link Digital input - Input type: Dry contact Universal inputs - 10k resistance, 1kΩ Balco input, 1kΩ Platinum input, 1k resistance, 10kΩ thermistor with 11k shunt resistors, voltage, current, digital input Digital outputs - Relay outputs: SW24H1, 2 & 3 current ratings LONMARK profile Fan Coil Heat Pump Rooftop Satellite Inputs/outputs 1 x digital input (DI) 1 x universal input (UI) 3 x digital outputs (DO) ACCESSORIES – see page 28 Controller MNL-10RF2 with Fan Coil Profile MNL-10RH2 with Heat Pump Profile MNL-10RR2 with Roof Top Profile MNL-10RS2 with Satellite Profile MNL-15RF2 with Fan Coil Profile MNL-15RH2 with Heat Pump Profile MNL-15RR2 with Roof Top Profile MNL-15RS2 with Satellite Profile MNL-20RF2 with Fan Coil Profile MNL-20RH2 with Heat Pump Profile MNL-20RR2 with Roof Top Profile MNL-20RS2 with Satellite Profile Data Sheet 10.100 All controllers use the same physical packaging, but differ in the onboard I/O points they provide. FEATURES • LONMARK compliant, programmable • Capability to function in stand-alone mode or as part of a LONWORKS FTT-10 Free Topology communications network • Proportional (P), Proportional Plus Integral (PI), and Proportional Plus Integral and Derivative (PID) control for cooling and heating • LED indication • Plenum-rated enclosure • Satellite profile allows controller to be used in a broad range of applications The VAV Series (Variable Air Volume) Controllers are interoperable, LONMARKcompliant devices. When loaded with an application from the WorkPlace Tech Tool application library or programmed with the WorkPlace Tech Tool, they provide a wide range of control strategies for pressure independent terminal boxes with, or without, reheat capabilities. Both models provide an integral actuator with manual override and an integral patented pressure transducer. LONMARK profile Fan Coil Heat Pump Packaged Rooftop Satellite Fan Coil Heat Pump Packaged Rooftop Satellite Fan Coil Heat Pump Packaged Rooftop Satellite Inputs/outputs 1 x digital input (DI) 2 x universal inputs (UI) 4 x digital outputs (DO) 3 x universal inputs (UI) 2 x digital outputs (DO) 2 x analogue outputs (AO) 2 3 6 2 x x x x digital inputs (DI) universal inputs (UI) digital outputs (DO) analogue outputs (AO) INSTALLATION DETAILS (cont) Protection class - IP 20 Mounting - 35mm DIN rail or panel Sensor inputs - MN Sx digital sensor link Digital inputs (MN 100 & 200 only) - Input type: Dry contact Universal inputs - 10kΩ thermistor, voltage, current, digital input Digital outputs - Current ratings: 24VA @ 24Vac, pilot duty Analogue outputs (MN 150 & 200 only) - Current: 0...20mA. (Output load 80...550Ω.) INSTALLATION DETAILS Power supply - 20.4...30Vac, 50/60Hz Consumption - 15VA @ 24Vac, 50/60Hz, excluding relay output power Surge immunity compliance - ANSI C62.41 (IEEE-587, Category A & B) ACCESSORIES LIB-4-485 RS 232/RS 485 converter to connect laptop to NCP network. PCM20H-485 PCMCIA Card to connect laptop PCs to ARCNET network (available from www.ccontrols.co.uk). Note: only suitable for use with Windows XP. WPA-LON-2 PC (PCMCIA) Card to connect laptop PCs to LONWORKS FTT-10 network. MN VAV ARK ® Controller MNL-5RF2 with Fan Coil Profile MNL-5RH2 with Heat Pump Profile MNL-5RR2 with Roof Top Profile MNL-5RS2 with Satellite Profile Data Sheet 10.070 MicroNet MN 100, 150 and 200 controllers are interoperable, LONMARK compliant units. When loaded with an application from the WorkPlace Tech Tool application library or programmed with the WorkPlace Tech Tool, these controllers provide control for packaged rooftops, heat pumps, fan coils, unit ventilators and similar applications. Data Sheet 10.220 Alarms can be acknowledged remotely from a GSM or WAPenabled mobile phone or from a Web browser. Message content can be customised and alarms can be routed according to alarm priority, type of alarm and time of day. This range of MicroNet MN 50 Controllers are interoperable, LONMARK compliant units. When loaded with an application from the WorkPlace Tech Tool application library or programmed with the WorkPlace Tech Tool, these controllers provide control for packaged rooftops, heat pumps, fan coils, unit ventilators and similar applications. Type MN-RAM Remote Alarm Manager, core MN-RAM-OUT ” FEATURES • Download VisiSat applications to single or multiple controllers and edit their properties • Uses VisiSat COM objects to communicate to the controller network • Utilises the well established reliability and ease of use of VisiSat MN 11 & 13 PRODUCT SELECTION Controllers (LONMARK®) (cont) Workplace Tech Tool Satchwell MicroNet ACCESSORIES – see page 28 Controller MNL-V1RV2 with integral actuator MNL-V2RV2 with integral actuator and fan and/or reheat control Control Cooling, none Cooling, series fan, induction, parallel fan, time prop, none Inputs/outputs 1 x digital input (DI) 1 x universal input (UI) 1 x digital input (DI) 1 x universal input (UI) 3 x digital outputs (DO) 1 x analogue output (AO) Reheat type None Other None Staged electric, Occupancy floating/proport satellite hydronic reheat, time proportioned, none Data Sheet 10.120 FEATURES • LONMARK compliant, programmable • Capability to function in stand-alone mode or as part of a LONWORKS FTT-10 Free Topology communications network • Integrated packaging with actuator, pressure transducer, and controller • Integral actuator with manual override and travel limit settings for easy set up and support • Proportional (P), Proportional Plus Integral (PI), and Proportional Plus Integral and Derivative (PID) control for cooling and heating • Plenum-rated enclosures • Air balancing using the MicroNet VAV Flow Balance software INSTALLATION DETAILS (cont) Velocity pressure input - Operating range: 0.0...0.622kPa Control range: 0.0025...0.498kPa Accuracy: ±5% @ 0.249kPa with Laminar flow @ 25°C and suitable flow station Protection class - IP 20 Sensor inputs - MN Sx digital sensor link Actuator output - Torque rating: 6Nm Stroke: Fully adjustable from 0...90°C Timing: Approximately 3 minutes at 60Hz (3.6 minutes at 50Hz) for 90° rotation @ 24Vac Position indication: Manual override: Pushbutton Digital (relay) outputs - MNL-V2RV2: SW24H1, 2 & 3 current ratings 24VA each @ 24Vac, 50/60Hz Digital input - Input type: Dry contact Universal input - 10k thermistor input, voltage, current, digital input Analogue output - MNL-V2RV2: Current 0...20mA (output load from 80...550Ω). INSTALLATION DETAILS Power supply - 20.4...30Vac, 50/60Hz Consumption - MNL-V1RV2: 12VA max. MNL-V2RV2: 84VA max. (12Va plus DO loads @ 24VA each) Surge immunity compliance - IEC 1000-4-5. ANSI C62.41 (IEEE-587, Category A & B) ACCESSORIES – see below and page 28 3/8” (9.5mm) to 1/2” (12.8mm) shaft adaptor AM-135 MNA-FLO-1 MicroNet VAV Enclosure for conduit applications MNL-FLOW-BAL MicroNet Flow Balance Software 27 PRODUCT SELECTION Controllers (LONMARK®) MN VAV Controller only for MicroNet LONMARk Controllers The MicroNet VAV Series (Variable Air Volume) Controller is an interoperable, LONMARKcompliant device. When loaded with an application from the WorkPlace Tech Tool application library or programmed with the WorkPlace Tech Tool, it provides control strategies for pressure independent terminal boxes, with or without reheat capabilities. Controller MNL-V3RV2 with fan and/or reheat control Control Cooling, series induction, parallel fan Inputs/outputs 1 x digital input (DI) 1 x universal input (UI) 3 x digital outputs (DO) 1 x analogue output (AO) 2 x triac outputs (TO) Reheat type Other Staged electric, Occupancy floating/proportional satellite hydronic, time Proportioned MN 500 INSTALLATION DETAILS (cont) Velocity pressure input - Operating range: 0.0...2.5” of W.C. (0.0...0.622kPa) Control range: 0.01...2.00” of W.C. (0.0025...0.498kPa) Accuracy: ±5% @ 1.00” of W.C. (0.249kPa) with Laminar flow @ 77°F (25°C) and suitable flow station Protection class - IP 20 Sensor inputs - MN Sx digital sensor link Digital outputs - Relay: SW24H1, 2 & 3 current ratings 24VA each @ 24Vac, 50/60Hz Triac: current ratings 0.75A (18VA) each output at 24Vac. Total of 18VA for both outputs Typical load: 24Vac synchronous motor with impedance protected windings Digital input - Input type: Dry contact Universal input - 10k thermistor input, voltage, current, digital input Analogue output - Current 0...20mA (output load from 80...550Ω). Programmable Bus-du-jour® controller ACCESSORIES – and see below MNA-FLO-1 MicroNet VAV Enclosure for conduit applications MNL-FLOW-BAL MicroNet Flow Balance Software Voltage Divider (converts 1...11Vdc signal to 0.45...5Vdc signal) for universal inputs 250Ω Shunt Resistor Kit for 4...20mA universal inputs Single LON Terminator for Free Topologies Double LON Terminator for Bus Topologies (two required) MicroNet Digital Sensors PC ISA Card (16-bit) to connect PCs to LONWORKS FTT-10 network PCMCIA Card to connect Laptop PCs to LONWORKS FTT-10 network PCLTA_20/FT-10 PCI 932-bit) Desktop Interface WorkPlace Tech Tool WorkPlace Tech Tool Unlock Codes Programmable Bus-du-jour® Controller Controllers (Bus-du-jour®) Programmable Bus-du-jour® Controller MN 440 Programmable Bus-du-jour® Controller The MN 300 controller is designed for unitary control, boilers and special applications that may require built-in transformers and relays. MNN-30-100 Controller Comms protocol Inputs/outputs NCP Controller NCP as standard ARCNET with plug-in card LONWORKS with plug-in card 8 x universal inputs 4 x triac outputs 3 x relay outputs The controller can function in stand-alone mode or as part of a networked system using Bus-du-jour communication options. Data Sheet 10.101 INSTALLATION DETAILS Power supply - 24Vac or 230Vac, 50/60Hz Consumption - 12VA Protection class - IP 20 Mounting - Wall or 35mm DIN rail Sensor inputs - MN Sx digital sensor link Inputs - 8 universal inputs (digital, resistive, 0...10Vdc) Outputs - 4 triac outputs for switching 24Vac 3 SPDT 230Vac relays (Line Relays) Current ratings (for triac outputs): 6Va at 230Vac supply, 18VA at 24Vac supply Power failure reserve - Controller EEPROM preserves memory for 10 years under normal conditions of use. The software clock will stop during a power failure. However, if the controller has an RTC card, the time will not be lost. FEATURES • LONWORKS FTT-10, ARCNET and NCP communications options - Bus-du-jour • Fully programmable using graphical objects • Three built-in 230Vac relays • 230Vac or 24Vac power supply combined with compact size • Time schedules • Switched outputs may be configured as stepped outputs (including plant rotation), actuator outputs or outputs for lights and fans • Eight fully programmable inputs - digital, analogue 0...10V, resistive 0...10Ω ACCESSORIES – see page 29 Controller Comms protocol Inputs/outputs NCP Programmable Controller NCP as standard ARCNET with plug-in card LONWORKS with plug-in card 6 x universal inputs 6 x digital outputs 3 x analogue outputs This controller is designed for rooftop, unit vent, air handling unit (AHU), and central heating and cooling applications. MNN-44-100 The controller can function in stand-alone mode or as part of a networked system using Bus-du-jour communication options. An optional Real Time Clock Card can be fitted to the MN 440 on an NCP network. Data Sheet 10.102 INSTALLATION DETAILS Power supply - 24Vac, 50/60Hz Consumption - 10VA Protection class - IP 20 Mounting - Wall or 35mm DIN rail Inputs - 6 universal inputs (digital, resistive, 0...10Vdc) Outputs - 6 digital outputs (triac) for switching 24Vac 3 analogue outputs (0...10Vdc) Current ratings for triacs: 18VA at 24Vac. Also has a 15Vdc power supply output capable of sourcing 25mA Power failure reserve - Controller EEPROM preserves memory for 10 years under normal conditions of use. The software clock will stop during a power failure. However, if the controller has an RTC card, the time will not be lost. FEATURES • LONWORKS FTT-10, ARCNET and NCP communications options - Bus-du-jour concept • Fully programmable using graphical objects • Intelligent multi-loop controller - up to 7 PID control loops • Time schedules • Proportional, integral and derivative control actions • 0...10Vdc for stepped fan control • Averaging module for analogue inputs • Six easily configurable inputs - digital, analogue 0...10V, resistive 0...10kΩ MNN-50-100 The controller can function in stand-alone mode or as part of a networked system using Bus-du-jour communication options. An optional Real Time Clock Card (RTC) can be fitted to the MN 500 on an NCP network. Other options include a remote mounting Touch Screen Display which allows the user to view, query and edit controller properties. An LCD display option is also available to review the controller parameters locally. Accessories for MicroNet Bus-du-jour Controllers Comms protocol Inputs/outputs NCP Programmable Controller NCP as standard ARCNET with plug-in card LONWORKS with plug-in card 2 x digital inputs 10 x universal inputs 6 x relay outputs 4 x analogue outputs INSTALLATION DETAILS Power supply - 24Vac, 50/60Hz Consumption - 12VA Protection class - IP 40 Mounting - Wall or 35mm DIN rail Inputs - 2 digital pulse counting inputs, 10 universal inputs (digital, resistive, 0...10Vdc) Outputs - 6 digital outputs (Line Relay) 5A resistive at 230Vac 4 analogue outputs (0...10Vdc) Power failure reserve - Controller EEPROM preserves memory for 10 years under normal conditions of use. The software clock will stop during a power failure. If the controller has an RTC card, then the time will not be lost. ACCESSORIES – and see main section below MN-DK Display Wall Mounting Kit MN-LCD-100 MicroNet LCD Display MN-LCDP-100 MicroNet LCD Display (for panel mounting) MN-TK Trunking Mounting Kit MNN-COM NCP Plug-in card MNN-TS-100 MicroNet Touch NCP Screen Display MNN-TSP-100 MicroNet Touch NCP Screen Display (for panel mounting) Controller Comms protocol Inputs/outputs NCP Programmable Controller NCP as standard ARCNET with plug-in card LONWORKS with plug-in card 8 x digital inputs 12 x universal inputs 8 x digital outputs 4 x analogue outputs The MN 620 Controller is designed for rooftop, unit vent, air handling unit (AHU) and central heating and cooling applications. MNN-62-100 The controller can function in stand-alone mode or as part of a networked system using Bus-du-jour communication options. An optional Real Time Clock Card can be fitted to the MN 620 on an NCP network. Other options include a touch screen and an LCD display. Data Sheet 10.104 INSTALLATION DETAILS Power supply - 24Vac, 50/60Hz Consumption - 15VA Protection class - IP 40 Mounting - Wall or 35mm DIN rail Inputs - 8 digital inputs, 12 universal inputs (digital, resistive, 0...10Vdc) Outputs - 8 digital outputs (triac). Current ratings 1A at 24Vac (24VA). 4 analogue outputs (0...10V) Power failure reserve - Controller EEPROM preserves memory for 10 years under normal conditions of use. The software clock will stop during a power failure. If the controller has an RTC card, then the time will not be lost. FEATURES • LONWORKS FTT-10, ARCNET and NCP communications options • Fully programmable using graphical objects • Intelligent multi-loop controller - up to 8 PID control loops • Optimisation module • Time schedules for plant and controller switching • Proportional, integral and derivative control actions can be individually set using controller objects • Twelve easily configurable inputs, 8 digital inputs • Eight triac outputs, four 0...10Vdc outputs ECH-74401 LIB-4-485 LON-TERM1 LON-TERM2 MN Sx MNA-C MNA-R10 MNL-C MNN-MI-100 MNN-RTC MN-VSCORE MN-VSLON WPA-LON-1 WPA-LON-2 ACCESSORIES – see main section below MN-DK Display Wall Mounting Kit MN-LCD-100 MicroNet LCD Display MN-LCDP-100 MicroNet LCD Display (for panel mounting) MN-TK Trunking Mounting Kit MNN-COM NCP Plug-in Card required for installation in MN 500 or MN 620, when connecting controller to NCP network MNN-TS-100 MicroNet Touch Screen Display MNN-TSP-100 MicroNet Touch Screen Display (for panel mounting) PCLTA-20/FT-10 PCI (32-bit) Desktop Interface RS 232/RS 485 Converter to connect PC to NCP network Single LON Terminator for Free Topologies Double LON Terminator for Bus Topologies (two required) MicroNet Sensors ARCNET Plug-in Card ARCNET Router LONWORKS Plug-in Card MicroNet Manager Interface Real Time Clock Card VisiSat Configuration Tool (requires Visio 2000 software), core software (NCP & ARCNET) VisiSat LON plug-in (requires MN-VSCORE), required for Bus-du-jour LON devices PC ISA card (16-bit) to connect PCs to LONWORKS FTT-10 network PC (PCMCIA) card to connect Laptop PCs to LONWORKS FTT-10 network ACCESSORIES – see page 29 28 Controller Data Sheet 10.103 FEATURES • LONWORKS FTT-10, ARCNET and NCP communications options • Fully programmable using graphical objects • Intelligent multi-loop controller - up to 8 PID control loops • Optimisation module and time schedules • Proportional, integral and derivative control actions • Ten fully configurable inputs - digital, analogue 0...10V, resistive 0...10kΩ • Six built-in line voltage relays, 230Vac 5A resistive • Optional LCD Display for interrogation of local parameters MN 620 MN 300 PRODUCT SELECTION The MN 500 controller is designed for district heating, boiler plant, air handling unit (AHU), and zone heating and cooling applications. Data Sheet 10.121 FEATURES • LONMARK compliant, programmable • Proportional (P), Proportional Plus Integral (PI), and Proportional Plus Integral and Derivative (PID) control for cooling and heating • Plenum-rated enclosure • Air balancing using the MicroNet VAV Flow Balance software • Directly compatible with terminal boxes which contain a synchronous-motor-driven damper actuator AD-8961-220 AD-8969-202 LON-TERM1 LON-TERM2 MN Sx WPA-LON-1 WPA-LON-2 ECH-74401 WP-TECH-CD-E-32 WP-TECH-32 Satchwell MicroNet Controllers (Bus-du-jour®) (cont) INSTALLATION DETAILS Power supply - 20.4...30Vac, 50/60Hz Consumption - 102VA max: 12VA plus DO loads (24VA each) and triac load (total 18VA) Surge immunity compliance - IEC 1000-4-5. ANSI C62.41 (IEEE-587, Category A & B) Accessories Satchwell MicroNet 29 PRODUCT SELECTION Satchwell MicroNet Digital Modules Fan Coil Unit Solutions The Digital Output Module is designed for use with Satchwell controllers having one or more 0...10Vdc outputs. The module allows the 0...10Vdc output(s) to drive voltage free single pole Changeover (SPCO) contacts that are mains rated. Each module has four relay output channels. 579-1-360 Control Input Output 4-channel 0...10Vdc 250Vac 3A resistive, 1A inductive Data Sheet 2.191 Associated controllers: IAC, MMC, CZT, KMC Fan Coil Control Loop Fan Coil Unit Solutions Air side control (4-pipe) Actuator slaving Sensor slaving URC-51N-103 BRC-41N-100 BRC-41N-101 BRC-51N-100 BRC-51N-101 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ On board transformer On board relays ✓ ✓ ✓ ✓ 1 1 1 1 Output for electric heater DX cooling ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Fan on/off Fan 3-speed control DRT DU DUS S1 (S-Link) S2 ” S3 ” S4 ” S4-FCS ” ✓ Duct sensors DDU DDT Actuator/valves AVU AVX BFB (Bonsai) ✓ ✓ ✓ ✓ Room sensors See page 37 ✓ ✓ ✓ MNL-13RF2 URC-51N-102 ✓ ✓ MNL-11RF2 URC-51N-101 ✓ ✓ BRC-51N-501 URC-51N-100 ✓ ✓ BRC-51N-500 URC-41N-103 ✓ ✓ ✓ ✓ BRC-41N-501 URC-41N-102 ✓ ✓ BRC-41N-500 URC-41N-101 2-pipe 2-pipe auto changeover 4-pipe ✓ ✓ ✓ ✓ ✓ ✓ URC-41N-100 Controllers CZU 4201 Networkable Standalone ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 3 3 3 3 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 31 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 1 3 1 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 3 1 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 1 3 ✓ 31 ✓ 3 1 3 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Controllers Type Bonsai Pro 230Vac BRC-41N-10X with on/off fan control (networkable) BRC-51N-10X with 3-speed fan control (networkable) Bonsai Lite 24Vac BRC-41N-50X with on/off fan control (stand-alone) BRC-51N-50X with 3-speed fan control (stand-alone) Where X denotes the pre-loaded application (possible to change on the field) 0 = 4-pipe FCU, 1 = 2-pipe with changeover URC-IR-100 Infra-red/RS 232 receiver URC-SET-100 NCP Palm/Expert commissioning software UniFact® Pro Terminal Unit Controllers x x x x x x DI DI – temperature AI – setpoint DO – triacs (-41N- only) DO – relays (-51N- only) Bonsai outputs Data Sheet 4.102 & 4.103 INSTALLATION DETAILS Control range - 0...40°C Control algorithm - Proportional + integral (time adjustable), or proportional only Power supply - 230Vac (+10%...–6%) Bonsai Pro, 24Vac (+10%...–6%) Bonsai Lite Power failure reserve - E2PROM preserves configuration data and user settings Triac for heater battery - 24Vac output, 2.4VA max Relay outputs - 230Vac, 5A resistive Network interface - RS 485 to Sigma or MicroNet network (-10X only) Sensor types - DU 4301, DUS 4302 or DDU 0001 (return air), MN-S1, S2, S3, S4 Controller protection class - IP 10 Mounting - Wall mounting or DIN rail mounting ACCESSORIES BCA 1601 – Controller enclosure for field mounting BCA 1602 – Controller set-point adjustment module (±3°C) BCA 9202 – Spare fuses (packet of 5) VALVE/ACTUATORS BFB 1500 BFB 1501 BFB 1506 BFB 1510 BFB 1516 BFB 1520 BFB 1525 Data Sheet 4.102 Size/Kvs 15mm – 15mm – 15mm – 15mm – 15mm – 15mm – 15mm – 1.6, 2.0, 2.5 Kvs * 0.6, 1.0 Kvs * 0.6 Kvs 1.0 Kvs 1.6 Kvs 2.0 Kvs 2.5 Kvs Loop compatible with: Bonsai BRC Controller Kvs = Flow in m3 to produce a 1 bar pressure drop when the valve is fully open. * Kvs is determined by a selectable Kv clip. INSTALLATION DETAILS Protection class - IP 52 Control medium - water or glycol solution in water (25% max, freeze protection) Temperature Limits - 2...95°C Bypass Kvs - 70% of rated Kvs International Pressure Rating - PN 10 Type of Operation - Rotary Actuator Protection Class - IP 52 Cable - 3 core fly lead with controller connection, length 1.5m Manual Override - By rotary movement of valve arm Position Indication - Reference moving part to actuator body ACCESSORIES BSA 1501 – 1m extension lead (one per actuator) URC-41N-10X URC-51N-10X Controller type with on/off fan control and S-link support with 3-speed fan control and S-link support Where X denotes the pre-loaded application (possible to change on the field) 0 = 4-pipe FCU, 1 = 2-pipe with changeover, 2 = DX cooling and electric heater, 3 = airside control URC-IR-100 Infra-red/RS 232 Receiver URC-SET-100 NCP Palm Commissioning Software The controller has three main modes: comfort (day), night (off) and economy. The controller can be switched into any of these three modes from the MicroNet View PC (if used). When used stand-alone, the controller can be switched between two modes: either comfort and economy, or comfort and night, as selected during commissioning. A voltage-free input (a timer switch, digital room sensor or PIR) can be used to switch between the two modes. A second voltage-free digital input is available for connection to a thermostat for automatic changeover between cooling and heating modes for 2-pipe fan coil unit (FCU) applications. Inputs/outputs 2 x DI 1 x RI – temperature 1 x AI – setpoint 4 x DO – triacs 3 x DO – relays Data Sheet 10.130 INSTALLATION DETAILS Control range - 0...40°C Power supply - 230Vac (+10%...–6%) Power failure reserve - E2PROM preserves configuration data and user settings Sensor types - DU 4301, DUS 4302, S1, S2, S3, S4 (room) or DDU 0001 (return air) Protection class - IP 20 Mounting - Wall mounting or DIN rail mounting FEATURES • Fully networkable or stand-alone controllers • Selectable control applications (fan-coil applications) • Low installation cost • Simple setup using PDA hand-held computer or PC via infra-red or RS 232 link • Designed to maximise energy savings • Optional networking to an MicroNet system 30 2 1 1 1 3 2 Valves • Patented Fluid Control Methodology • 3 main valve parts ensures reliable operation • Ultra low torque valve requirement/Low to silent operation • High speed of response • Dramatically reduces the chances of valve blockage • No user maintenance required • 'Tool free' manual override • Position indication • Variable Kv allows large range of applications • Modified equal percentage characteristic • 1.5m fly lead • IP 52 (actuator) • Market leading technology • Accurate performance across full ambient temperature range • Coil balancing bypass as standard • High differential pressure • Simple installation and commissioning The UNIFACTPRO Terminal Unit Controllers have been designed to meet virtually any fan-coil heating/cooling applications. The controllers can be used as stand-alone devices or can be networked to MicroNet systems. 26 Inputs/outputs FEATURES Controllers • Fully networkable or stand-alone controllers • Easy upgrade of old systems • High resolution control • Simple connection to controller • Controller tests and simulates operation to reduce commissioning times • Controller has built in maintenance cycles • Automated installation and commissioning • Selectable control applications (fan-coil applications) • Low installation cost • Simple setup using PDA hand-held computer or PC via infra-red or RS 232 link • Designed to maximise energy savings • Optional networking to an MicroNet system ✓ ✓ (cont) Select from a choice of controllers, valves and sensors to build your control loop. The control loop can be programmed locally and can be connected to Sigma or MicroNet if required (Bonsai Pro only). Alternatively it can be left to function stand-alone (Bonsai Lite). The controller meets the latest CEN application requirements and offers low cost engineering without maintenance. The patented valve design ensures long trouble free life Bonsai Pro & Bonsai Lite Function/associated products PRODUCT SELECTION Bonsai is a revolutionary new Fan Coil Control Loop that offers incredible performance and features. The loop is configurable to suit your applications by offering the latest technology and variable options. INSTALLATION DETAILS Power supply - 24Vac (±10%) 50Hz (–10%) to 60Hz (+10%) Consumption - 4VA max at 24Vac 50Hz Protection class - IP20 Indication - LED indication of channel status Overrides - 1 switch per channel giving ‘HAND’, ‘OFF’ and ‘AUTO’ positions FEATURES • Enables controller 0...10Vdc outputs to be used to switch mains relay contacts • LED indication of module output status • ‘HAND’ /‘OFF’ /‘AUTO’ override switch for each channel 579-1-360 Satchwell MicroNet 31 PRODUCT SELECTION Satchwell MicroNet Interfaces ® Bus-du-jour Manager Interface MNA-R10 ARCNET Router MNN-MI-100 MN-MI features two RS 232 ports that can be connected to a PC running VisiSat Configuration Tool or MicroNet View graphical user interface. One of the ports can be connected to a modem/Ethernet device server on a remote site to provide WAN connectivity. MN-MI can be configured to monitor alarm conditions and collect data logs. Touch Screen Display LCD Display Number of devices 20 x 61 max (per network) 31 x 94 max (per network INSTALLATION DETAILS Mounting - Panel or DIN rail Power supply - 24Vac Protection class - IP 40 This Router provides the means to extend an ARCNET network of MicroNet controllers and displays. MNA-R10 Up to 31 ARCNET sub-nets can sit on the back-bone. Routers can also provide opto-isolation between sub-nets. Data Sheet 10.215 FEATURES • Expands number of network devices • Extends network length • Parameter transfer between sub nets • Provides opto-isolation between networks • Complete with dedicated ARCNET card Controller MicroNet ARCNET Router MN Sx Digital Temperature Sensors Comms protocol ARCNET MNN-TS-100 MNN-TSP-100 MNL-TS-100 MNL-TSP-100 Number of devices 31 x 94 max (per network) FEATURES • NCP, ARCNET and LONWORKS Communications options • Intuitive, graphics-based menu system • Unique display for any LONWORKS systems • Built-in RTS and scheduling for LONWORKS networks Description NCP Touch Screen Display NCP Touch Screen Display (panel mounting) LON Touch Screen Display LON Touch Screen Display (panel mounting) Data Sheet 10.050 ACCESSORIES MN-DK Display Wall Mounting Kit for Touch Screen, available for MNN-TS-100 MNA-C ARCNET Plug-in Communications Card, available for MNN-TS-100 & MNN-TSP-100 INSTALLATION DETAILS Power supply - 24Vac Consumption - 2.5VA max Power failure reserve - EEPROM technology – clock backed up with battery The MicroNet Sensors MN Sx Series are a family of digital wall temperature sensors for use with I/A Series MicroNet Controllers. These sensors feature a Sensor Link (S-LK) communication protocol which provides a simple two-wire interface for power and exchange of sensor and subbase information. Subbase information includes selecting setpoint, fan speed, operating mode, or emergency heat. Available in six models, MicroNet Sensors provide an integral analogue-to-digital conversion for elimination of sensor-tocontroller noise effects and wire resistance offset. FEATURES • Aesthetically styled, low profile packaging • Digital zone temperature indication with variable resolution and unit of measure • Self-compensating temperature conversions remove the need for periodic calibration • Override button allows the user to switch to operation mode for out of hours occupation • Displays selected system values such as setpoint, external air temperature and operating mode • Enables the alteration of operating modes INSTALLATION DETAILS Power supply - 24Vac No. and type of PC communication ports - 1 RS 232 Power failure reserve - Non-rechargeable Lithium battery supports the unit’s RAM for up to 350 days Mounting - Wall or DIN rail Protection class - IP 40 This LCD Display is a text menu driven LCD display that allows a user to monitor and configure parameters of an MN 500 or an MN 620 controller. The display is fully programmable using the VisiSat Configuration Tool. Up to 246 lines of data can be displayed. MN LCD Controller Comms protocol MicroNet NCP as standard NCP Interface ARCNET with plug-in card Data Sheet 10.210A The Touch Screen Display is a graphic LCD display that allows a user to monitor and configure parameters for multiple controllers on a Native Communications Protocol (NCP) or an ARCNET communications network. MN TOUCH PRODUCT SELECTION Sensors The MicroNet Interface (MI) provides network-level supervision functions for a network of MicroNet controllers and displays. MN-MI Satchwell MicroNet MicroNet Sensors Keypad Display Sensor only none none MN-S2 Sensor with override 1 button LED override status indication MN-S3 Sensor with setpoint adjustment 2 buttons and override LCD and LED override status indication MN-S4 Sensor with setpoint, override and controller mode functions 5 buttons LCD and LED override status indication MN-S4-FCS Sensor with setpoint, on/off and fan speed functions 5 buttons LCD and LED fan status indication MN-S5 Sensor with setpoint, override controller mode functions and emergency heat key/indication 6 buttons LCD and LED override status indication Data Sheet 10.000 INSTALLATION DETAILS Power supply - Powered from the controller Protection class - IP 20 Ambient limits - Operating temperature 0...50°C, humidity 5...95% rh, non-condensing Adjustable Sensing Fan speed Switch scale range override function DU 4301 none –5...+50°C – – DUS 4302 +/– –5...+50°C – – DUSF 4351 +/– –5...+50°C Auto, off, on • DUSF 4352 +/– –5...+50°C Auto, off, 1, 2, 3 • Data Sheet 1.020 Associated controllers: MN 200/440/500/620 (DU & DUS only URC) These sensors are specifically used for Satchwell controllers. Models types have light that informs you that the controller is running. All sensors use the same single gang sized case. DU, DUS DUSF Description MN-S1 FEATURES • Small physical size • Attractive case design and neutral colour fits in with most room designs • Extra low voltage on all sensor types including fan speed control versions • Simple wiring connections • Simple commissioning • Controller running power light on the sensor INSTALLATION DETAILS Sensing element - Negative temp. coefficient thermistor Wiring - Low voltage dc (15Vdc), DU 3 wire, DUS 4 wire, DUSF 7 wire Power supply - 15Vdc from UniFact controller ACCESSORY 837-1-203 Guard Kit Description MN-LCD-100 LCD Display MN-LCDP-100 LCD Display (panel mounting) Data Sheet 10.060 FEATURES • Clear, high contrast LCD Display • Intuitive, text based menu system • Fully programmable with VisiSat Configuration Tool • Built-in Real Time Clock with battery back-up ACCESSORIES MNN-COM NCP Plug-in Card required for installation in MN 500 or MN 620, when connecting controller to NCP network MN-DK Display Wall Mounting Kit for LCD display, available for MN-LCD-100 MNN-50-100 MicroNet MN 500 NCP Controller MNN-62-100 MicroNet MN 620 NCP Controller MNA-C ARCNET Plug-in Card for MNN-50-100 or MNN-62-100 MNL-C LONWORKS Plug-in Card for MNN-50-100 or MNN-62-100 INSTALLATION DETAILS Power supply - 24Vac Consumption - 2.5VA max 15 Volt dc output - 30 mA max Power failure reserve - EEPROM technology – clock backed up with battery MicroNet System components can only be installed and commissioned by qualified MicroNet Partner engineers. 32 33 PRODUCT SELECTION Drayton Range Controllers Networkable Range DC1100 No –20...+120°C Inputs DC1100C Yes * for replacement purposes only A separate channel is provided for the control of hot water. Data Sheet 2.042 Each of the control routines can be used independently or combined. In effect the unit can be a compensator, an optimiser or a combined unit. Associated sensors - A701 (space), A702 (outdoor), A703 (immersion), A704 (strap-on), A705 (duct) LEDs provide an immediate visual indication of output status. INSTALLATION DETAILS Power supply - 230Vac, 50/60 Hz Protection class - IP 40 FEATURES • Controller can be a combined or stand-alone optimiser or compensator • One or two boiler control • Self learning compensator or fully settable • Self configuring or settable • Optimum start- and stop-self learning • Valve and boiler compensated flow • Hot water timed channel • Remote input (Auto/Summer/On/Holiday) • Frost protection – Multi stage ACCESSORIES 04 03 109 (RSU) RB1 This Fuel-saving Controller can replace a conventional time switch on a heating system and provides a variable start time dependent on the fall of room temperature during the off period. Output relay 6 x temperature sensors, 230V, 1A inductive 1 x remote switch unit (SPNO) (auto/summer/heating on/holiday) It will control one or two boilers, with requirements for optimum start and with direct or valve compensation. Self Configuring Optimiser/ Compensator SVT 7-day Optimiser Remote Switch Unit Interface Relay FEATURES (cont) • Day economy • Pump run on • Alarms on low temperatures, controller and sensor faults • Pump and valve exerciser • Space temperature influence of compensator A701 A702 A703 A704 A705 In addition to the regular sensors, there are also range variants and special limit sensors. Room, Outside, Immersion, Duct and Surface Sensors The space sensors are mounted in attractive white plastic housings to complement any decor. All other types are housed in sturdy diecast units with mounting arrangements suitable for their duties. Type Sensing range Associated controllers Room (Iss E) Outside (Iss E) Immersion (Iss D) Surface (strap on) (Iss J) Duct (Iss F) 0...45°C 0...120°C 0...120°C 0...120°C 0...120°C DC Range ” ” ” ” Output relays Plant, 250V, 2A (1A inductive) Control, 250V, 2A (1A inductive) Data Sheet 2.001 It is used to switch on and off central heating systems and will substantially reduce fuel consumption compared with fixed time starting. In all but the very coldest weather the start time is delayed until the latest time consistent with the amount of heat necessary to regain the required temperature at occupancy time. Compatible room sensor: DR 3253 (supplied with controller) INSTALLATION DETAILS Power supply - 230V 50/60Hz Power failure reserve - For clock - 100 hours, 2 hours for a short power interruption Protection class - IP 41 Compensators CSC Compensators are designed for use in residential/ commercial radiator systems to control either a three port mixing valve or a boiler. The controller senses outside temperature and varies the water flow temperature to the radiators. As the outside temperature falls, the radiator temperature is increased. The wide range of temperature sensors is designed specifically for use with Theta, and DC controllers and provides a selection suitable for most HVAC applications. Version Analogue clock Digital clock SVT 4201 SVT 4251 FEATURES • Easy installation - only one sensor required (packed with the controller) • Programme override switch • Choice of day control by separate compensator or built-in on/off day control • Minimum night ‘inside’ temperature protection • Analogue and Digital clock versions available Sensors A70 – PRODUCT SELECTION Optimiser The DC1100 is a stand-alone Direct Digital Controller, which has been designed to suit the control needs of the smaller commercial and larger domestic property. DC1100 DC1100C* Satchwell Controllers CSC Compensator Controllers Data Sheet 1.955 INSTALLATION DETAILS Sensoring element - Negative temp. coefficient thermistor Wiring - 2 wire non-polarised low voltage dc Adjustments - Concealed Protection class - IP 40 (space), IP 55 other types CSC 5252 CSC 5352 Control Mains or 24V output with no clock Mains or 24V output with clock Output Valve or boiler, 24Vac or 230Vac Valve or boiler, 24vac or 230Vac, Pump triac, 24Vac, 1A maximum Data Sheet 2.021 INSTALLATION DETAILS Power supply - 230Vac (+10%, –6%) 50/60Hz Power failure reserve - Settings stored in memory, 1 year battery for clock Protection class - IP 30 Switched inputs - Night Set Back (NSB): Voltage free, make/break contacts. Normally closed. Set Up (Boost): Voltage free, make/break contacts. Normally closed. Outputs - Valve actuator or boiler output relays: 2 x single pole ON/OFF (interlocked) 230Vac, 10A resistive, 6A inductive. Pump Output: 1 x 24Vac triac, 1A (0V switched). Clock version only. Output Supply: 2 x 24Vac terminals used to power external devices up to a total of 10VA maximum. Sensor inputs - ‘T’ type sensors Sensor types - DRT 3453, 3451 (optional), DWT 0001, DST 0001, DOT 0002 (see table below) An optional room temperature sensor can be used to trim the water temperature based on room temperature. The CSC can average up to four room sensors. FEATURES • Easy to install and commission • Shipped with typical default values • Operates a three port valve or boiler • Max. return function for District Heating applications • Adjustable economy function • Night Set Back (NSB) and set-up/boost inputs • Flow high limit feature • User configurable Day/Night plant operation • Room influence mode selection • Cost effective upgrade of all obsolete Climatronic controllers Relay & Switching Units Drayton relay units will operate over a wide range of ambient temperatures and are especially suited to heating and ventilating installations where they might be mounted in close proximity to boilers and other heat emitters. No. of switches Contact rating Suitable for: RB1 2 x DPCO 230V, 6A resistive General purpose RB2 3 x DPCO 230V, 6A resistive Valve/actuator Main Plant Controllers The CXR Controller is used to control room temperature by resetting the supply duct air temperature. The room sensor resets the duct supply temperature to achieve the desired room temperature. The room temperature can be sensed in the room or extract duct. The supply duct loop has a purely proportional control action with the room reset being a proportional plus integral control action. Data Sheet 21.685 RB1, RB2 FEATURES • Enclosed and easy to mount • Hassle free (time saving) • Simple design INSTALLATION DETAILS Power supply - 230V ac, 45/60 Hz Ambient limits - –18...66°C Relay Units CXR AHU Room Reset Controller This mode switch gives an easy means of overriding the DC1100 controller. The remote switch has four settings – Auto, Summer, Heating On and Holiday. 04 03 109 Data Sheet 2.043 FEATURES • User friendly • Clearly labelled • Positive feel switch reduces ambiguity of position 04 03 109 (RSU) Remote Switch Unit For use with DC 1100 controllers only CXR 5805 Control Single, two or three stage Output 24V actuator control Data Sheet 2.110 INSTALLATION DETAILS Power supply - 230Vac (+10%, –6%) 50/60Hz Power failure reserve - settings stored in memory, 1 year battery for clock Protection class - IP 30 Switched inputs - Night Set Back (NSB): Voltage free, make/break contacts. Normally closed. Set Up: Voltage free, make/break contacts. Normally closed. Remote Low Limit (Summer): Voltage free, make/break contacts. Normally closed. Night Sensor Selection: Voltage free, make/break contacts. Normally closed. Outputs - Valve Actuator Output Triacs: 2 x 24Vac triacs, 1A (0V switched and software interlocked). Output Supply: 2 x 24Vac terminals used to power the actuator up to a total of 10VA maximum. Sensor inputs - ‘T’ type sensors Sensor types - DRT 3651, 3453, DDT 0001, DWT 0001, DST 0001, RPW 4425 (see table below) FEATURES • Easy to install and commission • Shipped with typical default values • Quick set mode allows basic settings to be easily checked and set • Simple override switch • Night Set Back (NSB), set-up, summer and night sensor selection switched inputs • Optional Scandinavian night sensor • Up to 4 room sensors can be used for average room temperature • Remote setting input for room set value (RPW) • Cost effective upgrade of all obsolete Climatronic controllers SENSORS AND REMOTE SETTING UNIT DRT 3651, 3453, 3451 DDT 0001 DWT 0001 DST 0001 DOT 0002 RPW 4425 34 35 Type Room Duct Water Water (strap on) Outside Remote Set Value Range –5...+40°C –5...+100°C –10...+120°C 5...120°C –40...+55°C 5...50°C PRODUCT SELECTION Satchwell Controllers Main Plant Controllers PID Pulse 24V Controller CZT PID 0-10Vdc Controller Control Single or two stage CXT 5605 Output 24V actuator control This PID Controller can be used to control humidity or temperature in various ventilation and air conditioning system applications. Data Sheet 2.101 INSTALLATION DETAILS Power supply - 230Vac (+10%, –6%) 50/60Hz Power failure reserve - Settings stored in memory, 1 year battery for clock Protection class - IP 30 Switched inputs - Night Set Back (NSB): Voltage free, make/break contacts. Normally closed. Set Up: Voltage free, make/break contacts. Normally closed. Outputs - Valve Actuator Output Triacs: 2 x 24Vac triacs, 1A (0V switched and software interlocked). Output Supply: 2 x 24Vac terminals used to power the actuator up to a total of 10VA maximum. Sensor inputs - ‘T’ type sensors Sensor types - DDT 0001, DWT 0001, DST 0001, RPW 4425 (see table on previous page) FEATURES • Easy to install and commission • Shipped with typical default values for the parameters, decreasing commissioning time • Quick set mode allows basic settings to be easily checked and set • Simple override switch • Operates single or two stage systems • Night Set Back (NSB) and set-up inputs • Supports new or old generation Satchwell sensors • Remote setting input for room set value (RPW) • Cost effective upgrade of all obsolete Climatronic controllers The CZT Controller is designed for use in systems such as room or return water control. the CZT can be used for single or two stage control. the CZT is suitable for use with 0 to 10Vdc actuators and/or step controllers. CZT 5305 Control Single or two stage FEATURES • Easy to install and commission • Shipped with typical default values for the parameters, decreasing commissioning time • Quick set mode allows basic settings to be easily checked and set • Simple override switch • Operates single or two stage systems • Standard 0...10Vdc output • Night Set Back (NSB) and set-up inputs • Existing CZT sensors can be used • Remote setting input for room set value (RPW) • Cost effective upgrade of all obsolete Climatronic controllers INSTALLATION DETAILS Power supply - 230Vac (+10%, –6%) 50/60Hz Power failure reserve - Settings stored in memory, 1 year battery for clock Protection class - IP 30 Switched inputs - Night Set Back (NSB): Voltage free, make/break contacts. Normally closed. Set Up: Voltage free, make/break contacts. Normally closed. Outputs - Control outputs: 2 x 0...10Vdc outputs for heating and cooling. Output Supply: 2 x 24Vac terminals used to power the actuator(s) up to a total of 10VA maximum. Sensor inputs - ‘T’ type sensors. Sensor types - DRT 3651, 3453, 3451, DDT 0001, DWT 0001, DST 0001, RPW 4425 (see table on previous page) MMC 4701 Universal Air Handling Unit Controller Output 0...10Vdc for heating and cooling Data Sheet 2.105 MMC 4601 Multi-loop District Heating Controller The FLS is a Step Control Function Module which is designed to be used in conjunction with 0 to 10Vdc output Controllers thus providing a stepped on/off output from one or more stages. C/O Step Control Function Module Relays Voltage Free ContactsPower Supply 6 230Vac, 2A (IA inductive) 24Vac Control PID Range –40…+150°C 0…100% rh Output 3 x 0...10Vdc 2 x 24V digital Power Supply 24vac Data Sheet 2.701 FEATURES • Serial link • Can be programmed through its own keyboard • Low voltage (24Vac) • Proportional + Integral + Derivative control action for stable control without offset • Eleven applications to deal with most humidity and temperature control schemes • Built-in real time clock and time schedule The controller can be configured to run in one of the applications by simply selecting that application number. 1. Single Stage Temperature Controller 2. Two Stage Temperature Controller 3. Three Stage Temperature Controller 4. Three Stage Room Temperature Reset Controller with Heat Recovery 5. Three Stage Cascade Temperature Controller 6. Single Stage Temperature Controller (24Vac Actuator Output) 7. Single Stage Humidity Controller 8. Two Stage Humidity Controller 9. Simple Single Stage Temperature Controller 10. Simple Two Stage Temperature Controller 11. Simple Three Stage Temperature Controller INSTALLATION DETAILS Power failure reserve - Settings stored in memory for 1 year, 5 year battery Inputs - Sensors: DRT, DDT, DOT, DRH, DDH, DOW, DOS, DWT Outputs - Actuators: ALi, ALE, ALES, AVUE 24Vac switched outputs: 2 x digital outputs, ALX, ALXS, ARX Protection class - IP 40 when flush mounted Control Multi-loop The MMC is a Multi-loop Controller for use in district heating schemes. MMC 4601 The controller incorporates three separate control loops, two compensated and the other a constant temperature loop. Data Sheet 2.751 Up to 3 specific points are programmed for the compensation graph. The MMC automatically joins up these points to produce a user defined compensation curve. This adjusts and calculates the required set value of the supply temperature to the compensated system to match the prevailing requirements. Range –40…+150°C Output 2 x 0...10Vdc 2 x 24V digital Power Supply 24Vac FEATURES (cont) • Fast response time ensures suitability for tap water control • Compensation curve can have up to three programmable points giving the curve two calculated ratios • Supply high limit • Built-in ‘default programme’ of typical settings for every parameter operates on initial start-up • 0...10Vdc control outputs • PID programmable control loops • Periodic pump cycling • Frost protection logic INSTALLATION DETAILS Power failure reserve - Settings stored in memory for 1 year, 5 year battery Inputs - Global sensors Outputs - Actuators: ALi, ALE, ALES, AVUE 24Vac switched outputs: 2 x digital outputs Protection class - IP 40 when flush mounted Associated input devices - IAC, MMC, CZT, KMC INSTALLATION DETAILS Running time though 0...10V stroke - 180 seconds (adjustable 60 to 720 seconds) Protection class - IP 40 when flush mounted Terminal Unit ACCESSORY 866-1-405 Panel Mounting Kit KMC 3201 Control Range PID –40…+150°C 3-stage temp. 0…100% rh 2-stage humidity Output 0...10Vdc for heating or cooling FEATURES (cont) • Low voltage (24Vac) • Proportional + Integral + Derivative control action for stable control without offset • Default programme of typical settings for each parameter operates on initial start-up • Security code prevents unauthorised access to setting parameters • Five applications to deal with most humidity and temperature control schemes, see the previous section for details of each scheme • The KMC can be used in place of the Satchwell KZT, KZH and KET controllers • Real Time Clock (RTC) on the two humidity applications The KMC control stage outputs are all 0...10Vdc, except the single stage humidity application that has an optional 24Vac pulsed output. The controller can be configured to run in one of the applications by simply selecting that application number. 1. Single Stage Humidity Controller 2. Two Stage Humidity Controller 3. Single Stage Temperature Controller 4. Two Stage Temperature Controller 5. Three Stage Temperature Controller The CZU is an Electronic Modulating Controller for the control of terminal units or fan coils in air conditioning systems serving small zones of buildings such as individual offices and hotel bedrooms. Power Supply 24Vac Data Sheet 2.120 The KMC is designed to carry out the general control functions of the Satchwell KZT, KZH and KET controllers with the added benefit of a digital display. Multiple Application PID Controller The serial link function allows the MMC to be fully integrated into a networking system with all the advantages of remote monitoring, alarms, logging, graphics and remote setting of all control parameters. The MMC can work as a fully stand-alone controller. FEATURES • Serial link • Can be programmed through its own keyboard • Real Time Clock (RTC) • Self tuning for each control loop, maximises efficiency for each loop Data Sheet 2.195 FEATURES • Six steps available • Indication LEDs show status of each relay step • Provides step control of electric heaters and alike • Panel mounting optional The KMC Controller can be used to control humidity or temperature in ventilation and air conditioning systems. The KMC uses Satchwell sensors to monitor humidity or temperature and control the plant. KMC Control Input 0...10Vdc FLS 1502 MMC 4701 The MMC has a self tuning function that allows each of the 3 control loops to have its proportional band, integral action and derivative action values automatically tuned. Self tuning can be carried out from the MMC keyboard or from optional external momentary switches connected to it. Self tuning maximises the efficiency of control loop operation. Keyboard FLS PRODUCT SELECTION Keyboard The CXT Controller is primarily designed to control systems with short time constants and fast response times. This would typically be the control of heat exchangers, non storage calorifiers or ventilation plant where the sensor is placed directly in the controlled medium. The CXT operates 24Vac actuators on two or three port valves. It is capable of operating single or two stage systems. CXT Satchwell Controllers CZU 4201 Fan Coil Unit Controller 36 Output 24V actuator control INSTALLATION DETAILS Power supply - 24Vac (±10%) 50/60Hz Protection class - IP 20 Override inputs - TSM 1501: Pipe surface thermostat Adjustments - Set Value: 10…40°C, Proportion Band: 0…3°K per stage Dead Zone: 0…6°K, Actuator Stroke Setting: 12.5…75mm Sensor inputs Type Range DRT 3451, 3453, 3801, 3851 Room –5...+40°C DDT 0001 Duct –5...+100°C DDU 0001, 1803 Duct –5...+40°C FEATURES • Simple installation • Three wire connection to actuators • Optional auto changeover • Minimal commissioning time INSTALLATION DETAILS Power failure reserve - Settings stored in memory, 5 year battery for clock Inputs - Sensors: DRT, DDT, DOT, DRH, DDH Outputs - Actuators: ALi, ALE, ALES, AVUE 24Vac switched outputs: 2 x digital outputs, ALX, ALXS, ARX Protection class - IP 40 when flush mounted FEATURES • Direct digital control • Programmed via the keyboard and display • Digital display provides comprehensive indications of all current parameter values, settings and measurements Range 10...40°C Data Sheet 2.201 The range includes temperature sensors and actuators for valve operation and associated two, three and four port valves. CZU Control 2-stage heating and cooling with dead zone 37 PRODUCT SELECTION Satchwell Controllers Networking Intelligent/Programmable The Modem Interface Unit provides the necessary link between a modem and Satchwell Networking controllers on a remote site, when using Satchnet Pro Networking Software. An RS232 input is provided for connection to a modem on a Wide Area Network (WAN). The MIU is then able to be connected (via its RS422/485 link) to upto 31 Networking controllers. MIU Modem Interface Unit Satchwell Controllers/Sensors MIU 4252 Comms. ports Comms. speed Max. cable length 1 - RS232 1200, 2400, 4800 or 9600 BPS 15m 2 - RS422/485 1200, 2400, 4800 or 9600 BPS (opto isolated) 1000m IAC 600 INSTALLATION DETAILS Power supply - 24Vac (±15%) 47/63Hz Protection class - IP 41, IP 00 if the RS232 connected is used Mounting - DIN rail or surface mounting Status display - 5 LEDs Power failure reserve - E2PROM preserves configuration data such as password, telephone numbers, baud rate (if LK 5 is not used) etc. Universal MultiLoop Intelligent Advanced Controller ACCESSORY 841-2-201 Real Time Clock Board IAC 420 Universal MultiLoop Intelligent Advanced Controller Terminals Fixed Plug-in IAC 420 - F IAC 420 - P The IAC has pre-sets to control common applications such as terminal unit control, VAV and zone control. In addition the controller can be customised to work on other less common applications. Data Sheet 2.801 Control 3 loop Range –40…+150°C 20…90% rh 250…9750 Ohms 0…10,000 Lux FEATURES (cont) • 15Vdc supply output for humidity, pressure and UniFact sensors • 0...10Vdc or stepped fan control • Averaging of temperature (resistive) sensors and analogue inputs • Three off two stage controllers with each stage individually selected as PID, PI or P only • Three cascade controllers • Optional Real Time Clock (RTC) board available The Satchnet software is used to program and monitor the IAC controllers. FEATURES • Compact size allows mounting in a confined space such as on a fan coil unit • Serial link • IACs configured from a computer using the simple Bubbleland graphical interface • Internal software time clock, controller and lighting time schedules • Complies with latest European EMC standards • Switched outputs may be configured as stepped outputs (including plant rotation), actuator outputs or outputs for lights and fans • Six configurable inputs that can be individually configured as temperature (resistive), analogue (0...10Vdc) or Digital (Switched) inputs • 0...10 volt inputs can be used for humidity/pressure/velocity control or as a reset input • Resistive inputs can be used for Satchwell “T” type temperature sensors, RPW remote setting units, Ohms and Light sensors (NORP-12 Light Dependent Resistor (LDR)). The base unit’s 6 control loops are configurable and can be used, for instance, to control the pre-heater, the main duct temperature, humidity, and re-heat. One advantage of this integrated multi-loop controller is that the normal interlocks set up between discrete controllers on a typical system, are carried out internally by the controller, thus saving on external wiring. The IAC unit also has a clock and time schedules built-in which are used to switch plant control modules etc. the IAC includes full plant sequence control and rotation based on plant hours run to control Chillers and Boilers as required. The controller also includes a number of preset applications in the software to cater for typical control schemes. for IAC 600 Controller INSTALLATION DETAILS Power supply - 24Vac (±10%) 47/63Hz 15 Volt dc Output - 25 mA max Power failure reserve - E2PROM preserves configuration data and user settings. Inputs: 6 x configurable inputs Outputs: 3 x 0...10V outputs, 6 x digital (triacs on/off) outputs Protection class - IP 20 Mounting - DIN rail or surface mounting Outputs 4 x 0...10Vdc 8 x on/off triac 1 x 15Vdc FEATURES (cont) • Six temperature (resistive) sensor inputs • Six 0...10Vdc inputs for humidity, pressure and velocity • Eight Voltage free switched inputs for use as alarms, Pulse counting etc • Proportional, Integral and Derivative control actions can be individually set on each controller module • Lighting and chiller/boiler Sequence control • Internal time clock and time schedules for plant and controller switching INSTALLATION DETAILS Power supply - 24Vac (±10%) 50/60Hz 15 volt dc output - 30 mA max Power failure reserve - Non volatile RAM preserves memory for 10 years under normal conditions of use. Inputs - Sensors: Six temperature (resistive). Six 0...10 Volt dc, max input 10 Volts dc Digital input: Eight voltage free contacts, opto isolated. the inputs can be used for pulse counting, 0.5Hz max. They can also be used for alarms, overrides etc. Serial link: EIA standard RS422/485 half duplex opto isolated Outputs - Actuators: Four 0...10 Volt dc. Eight digital (triac on/off) outputs Protection class - IP 20 Mounting - DIN rail or surface mounting This optional Touchscreen gives access to upto 31* IAC base units on its own sub LAN (including the IAC 600, 400, 420 and 200). The Touchscreen is mounted direct on the IAC base unit. Touchscreen Range –40…+150°C 20…90% rh 250…9750 Ohms 0…10,000 Lux Data Sheet 2.951 FEATURES • Intelligent Multi-loop Controller – up to 6 PID control loops • Compensation and optimisation modules • Configured via Satchsoft Networking • Standard selectable applications built in to the controller Outputs 3 x 0...10Vdc 3 x 24V pulsed 24V switched 1 x 15Vdc Control 6 x PID loops IAC 600-B The Satchnet Bubbleland software is fully graphical. Setting and amending the IAC configurations involves selecting and joining the required modules using the mouse. Intelligent/Programmable This Intelligent Advanced Controller is designed for use in small and large buildings such as office blocks, hotels and schools. The IAC has a stand alone capability, and may be configured from a central computer over the serial link. (cont) The IAC 600 is a Multi-loop Configurable Controller designed primarily for use in typical multi-loop situations such as air-conditioning systems and Central Plant Heating/Cooling Systems. Data Sheet 2.511 FEATURES • RS232 and RS422/485 ports • Autoanswer operation on modem sites • Optional battery backed up Real Time Clock Board • Allows a further 32 Networking controllers to be connected, making a maximum of 63 on a single LAN PRODUCT SELECTION Part number & item IAC-TS Touchscreen Data Sheet 2.951 The Touchscreen allows the user to interrogate the IACs by using the touch sensitive screen and menu system. Information on the sensor values and outputs can be displayed and parameters can be altered if required. The Touchscreen contains a battery backed clock that is used by the IACs on the sub LAN as a back up to their own internal clocks. INSTALLATION DETAILS Power supply - Powered from the IAC unit Power failure reserve - Non volatile RAM with built-in Real Time Clock gives 3 year back up of clock and memory under normal conditions of use. ACCESSORY DDC 2601 Remote Touchscreen Adaptor Kit * Dependent on the number of parameters to be displayed. Each Touchscreen can display upto 256 parameters. FEATURES • Mounts on IAC base unit or optional panel mounting • Touch sensitive graphic LCD screen • Menu operation for interrogation and setting • Back-lit screen for easy viewing • Communicate with up to 31 - IACs • Battery backed clock provides time synchronisation ACCESSORY 841-1-201 Real Time Clock Board Room Temperature, Temperature/humidity & Carbon Dioxide Sensors Designed for use with Satchwell controllers to provide temperature control of heating and air conditioning plant. DR/DRT Air Temperature Sensors FEATURES • Aesthetically pleasing case designs • Small physical size • Wide temperature sensing range • Simple wiring connections • Simple commissioning INSTALLATION DETAILS Sensing element - Negative temp. coefficient thermistor (0...10k ohm) Wiring - Low voltage dc, DRT - 2, 3 or 4 wire and DR - 2 wire Designed for use with controllers to provide temperature control of heating and air conditioning plant. DRT Room Temperature Sensors 38 FEATURES • Aesthetically pleasing case designs • Small physical size • Wide temperature sensing range • Simple wiring connections • Simple commissioning DR 3253 DRT 3451 DRT 3453 DRT 3651 DRT 3652 Data sheet Adjustable scale (exposed) none 10...35°C none 10...35°C 10...35°C + LED For use with controller or controller actuator types Sensing CZT CSC LIB MMC CZU KMC IAC SVT BAS range CXR MN Sigma –5...+40°C – – – – – – – – • –5...+40°C – – – – – • – • – –5...+40°C • • • • • • • – • –5...+40°C • – – • – • • – • –5...+40°C – – – – – – – • – 2.105 2.021 2.041 2.701 2.201 2.120 2.951 2.001 13.341 2.110 2.541 2.751 10.XXX 13.XXX Data Sheet 1.001 ACCESSORIES 837-1-203 DR/DRT Guard Kit - protects against impact and tampering 837-1-352 DRT +/– Scale Converter – used to convert standard exposed adjustment types. Consists of just the sensor front cover. Suitable for DRT 3451 and 3651. For use with controller or controller actuator types Adjustable scale Sensing CZT CSC LIB MMC CZU KMC IAC SVT BAS (exposed) range CXR MN Sigma DRT 4453 none –5...+40°C • • • • • • • – • Data sheet 2.105 2.021 2.041 2.701 2.201 2.120 2.951 2.001 13.341 2.110 2.541 2.751 10.XXX 13.XXX Data Sheet 1.040 INSTALLATION DETAILS Sensing element - Negative temp. coefficient thermistor (0...10k ohm) Wiring - Low voltage dc, DRT - 2, 3 or 4 wire 39 PRODUCT SELECTION Satchwell Sensors Room Temperature, Temperature/humidity & Carbon Dioxide Sensors Sensors incorporate fan speed control switches and are used with CZU and IAC temperature controllers. This system is used for the control of temperature zones in buildings, such as hotel bedrooms or individual offices, which are air conditioned by fan coil units. DRT Temperature Sensors with Fan Speed Switches Satchwell Sensors Room Temperature, Temperature/humidity & Carbon Dioxide Sensors (cont) Adjustable scale Sensing range No. switch Switch positions position DRT 3801 10...35°C 10...35°C 2 0, 1 DRT 3851 10...35°C 10...35°C 4 0, 1, 2, 3 Switch function Off, on Off, on, medium, high Associated controllers: CZU, IAC INSTALLATION DETAILS Sensing element - Negative temp. coefficient thermistor Wiring - 2 wire low voltage dc, non-polarised to controller Switch rating - 2.5A 250Vac. Motor full load current. 12A motor starting, 250Vac. Note: manual switches suitable for choke controlled or capacitor controlled fan motors. DRCO Infrared Analyser CO2 Sensor (cont) Measurement Repeatability Operating range (selectable) temp. The DRCO is a non-dispersive infrared analyser designed for measuring environmental CO2 concentration in indoor living spaces. Its measurement range of 0...2000 or 0...5000 ppm covers the range required to monitor compliance with ASHRAE or other ventilation efficiency standards. Data Sheet 1.002 FEATURES • Aesthetically pleasing case designs • Robust • Easy to operate • Simple wiring connections • Simple commissioning PRODUCT SELECTION DRCO 2702 An LCD display is available to provide local indication of CO2 concentration and facilitate the setup and calibration process. An adjustable setpoint relay is available for direct control and alarm applications. Microprocessor-based digital electronics and a unique self-calibration algorithm improves long-term stability and accuracy. 0...2000 or 0...5000 ppm ±20 ppm 0...50°C Input voltage Analogue output (selectable) 20...30V ac/dc 0...5Vdc, 0...10Vdc or 4...20mA Data Sheet 1.601 Protection class - IP 20 Accuracy - ±75 ppm Response time - <60 seconds for 90% step change Duct Temperature, Temperature/humidity, Carbon Dioxide & Pressure Sensors Adjustable Sensing Fan speed Switch scale range override function DU 4301 none –5...+50°C – – DUS 4302 +/– –5...+50°C – – DUSF 4351 +/– –5...+50°C Auto, off, on • DUSF 4352 +/– –5...+50°C Auto, off, 1, 2, 3 • Data Sheet 1.020 Associated controllers: MN 200/440/500/620 (DU & DUS only URC) These sensors are specifically used for Satchwell controllers. Models types have light that informs you that the controller is running. All sensors use the same single gang sized case. DU, DUS DUSF MicroNet Sensors FEATURES • Small physical size • Attractive case design and neutral colour fits in with most room designs • Extra low voltage on all sensor types including fan speed control versions • Simple wiring connections • Simple commissioning • Controller running power light on the sensor INSTALLATION DETAILS Sensing element - Negative temp. coefficient thermistor Wiring - Low voltage dc (15Vdc), DU 3 wire, DUS 4 wire, DUSF 7 wire Power supply - 15Vdc from UniFact controller This sensor’s revolutionary adjustable probe length enables the user to find the best monitoring position with ease. It is designed to be used with Satchwell controllers to provide temperature control in ventilation systems. DDT 0001 Air Temperature Sensor ACCESSORY 837-1-203 Guard Kit The DRTE Active Sensor gives proportional 0...10Vdc output for control of rooms or small zones. The sensor will control actuators such as Satchwell ALi and ARE. Alternately the output can be used as a low limit on other 10 volt equipment or as a reset signal to other controllers. DRTE Active Temperature Sensor DRTE 2201 Data Sheet 1.101 FEATURES • Tamperproof • Small physical size • Reversible output ramp: heating or cooling • Low cost installation • Simple commissioning Active Temperature Sensors with Fan Speed Switches Room Humidity/ Temperature Sensors Sensing range No.switch positions Switch position Switch function DRTE 2801 10...40°C 10...35°C DRTE 2851 10...40°C 10...35°C 2 0, 1 Off, on 4 0, 1, 2, 3 Off, on, medium, high Data Sheet 1.102 INSTALLATION DETAILS Sensing element - Negative temp. coefficient thermistor Switch rating - 2.5A 250Vac. Motor full load current. 12A motor starting, 250Vac. Note: manual switches suitable for choke controlled or capacitor controlled fan motors. DRH 7702 Sensing Accuracy Temp. sensor Control range Relative humidity only ±2% rh* None 0...90% rh and 0...+50°C T type Humidity: 0...90% rh and 0...+50°C Temperature 0...+100°C DRH 7703 Models are available with humidity sensing only or humidity combined with temperature sensing. Two ranges of resistive outputs are available across the monitored temperature range i.e. T type or standard NTC thermistor. 2% and 1% accuracy versions are available certified for the National Institute of Standards Technology (NIST). DRTH 7712 “ ±3% rh* Relative humidity and temp. ±2% rh* DRTH 7713 “ DRTH 8731 “ Data Sheet 1.502/1.504 ±3% rh* ±1% rh** 0...10Vdc *@10...90% rh ACCESSORIES HDS 9201 1% Humidity Element (NIST Certified) HDS 9202 2% Humidity Element (NIST Certified) HDS 9102 Replacement Humidity Element (2%) HDS 9103 Replacement Humidity Element (3%) DDH 7602 Spring clip Sensing Accuracy Temp. sensor Control range Relative humidity only ±2% rh* None 0...90% rh and 0...+50°C NTC thermistor Humidity: 0...90% rh and 0...+50°C DDH 7603 “ DDTH 7612 ±3% rh* Relative humidity and temp. ±2% rh* DDTH 7613 “ ±3% rh* Temperature: 0...+100°C FEATURES • 0...10Vdc or 0...5Vdc humidity output • 24Vac or 12...24Vdc input power • Humidity sensor element contained in removable probe tip; replacement element available • Small physical size • Simple wiring connections and commissioning Data Sheet 1.503 *@10...90% rh ACCESSORIES HDS 9201 1% Humidity Element (NIST Certified) HDS 9202 2% Humidity Element (NIST Certified) HDS 9102 Replacement Humidity Element (2%) HDS 9103 Replacement Humidity Element (3%) FEATURES • Suitable for clean, dry air or any inert gas • Field selectable output voltages • Rapid dynamic response • Short circuit and reverse polarity protection Mounting type LCD display DDP 5601 DDP 5610 Duct ” No ” 24.9/62.2/124.5/249 4...20mA or 0...5/0...10V ±24.9/±62.2/±124.5/±249 ” DDP 6601 DDP 6610 Panel ” Yes “ 249/622/1245/2490 4...20mA or 0...5/0...10V ±249/±622/±1245/±2490 ” Data Sheet 21.606 Pressure ranges (pa) (field selectable) 41 Output (field selectable) Associated controllers: URC, IAC 420, IAC 600, MN300...620, BAS, Sigma INSTALLATION DETAILS Accuracy - ±1% f.s. Dynamic response - <5msec Protection class - IP 65 ACCESSORY 40 5573Ω INSTALLATION DETAILS Sensing element - Negative temp. coefficient thermistor Wiring - 2 wire non-polarised low voltage dc These sensors are for the control of air pressure in duct-work by the regulation of variable volume fans and pressure regulating dampers in distribution systems and terminal units. They can also be used for monitoring air filter conditions. Differential Air Pressure Sensor Direct Associated controllers: CZU, IAC, URC, BRC, MN300...MN620, Sigma INSTALLATION DETAILS Power supply - 24Vac or 12...24Vdc for humidity sensors Humidity sensor - Digitally profiled thin-film capacitive element Temperature effect - ±0.03% rh/°C over 0...50°C Stability - ±1% rh annually at 20°C Protection class - IP 65 Ambient limits - Operating temperature 0...60°C, humidity 10...90% rh, non-condensing Compatible controllers - KMC, MMC, IAC, MicroNet, BAS, Sigma DDP Fixing 5573Ω DDU 1803 Models are available with humidity sensing only or humidity combined with temperature sensing. Two ranges of resistive outputs are available across the monitored temperature range i.e. T type or standard NTC thermistor. INSTALLATION DETAILS Power supply - 24Vac or 12...24Vdc for humidity sensors Humidity sensor - Digitally profiled thin-film capacitive element Temperature effect - ±0.03% rh/°C over 0...50°C Stability - ±1% rh annually at 20°C Protection class - IP 20 Ambient limits - Operating temperature 0...60°C, humidity 10...90% rh, non-condensing Compatible controllers - KMC, MMC, IAC, MicroNet, BAS, Sigma FEATURES • Aesthetically styled, low profile packaging • 0...10Vdc humidity output • 24Vac or 12...24Vdc input power • Humidity or humidity and temperature output • Removable Humidity sensor element; replacement elements available • 1% and 2% versions supplied with NIST certificate Resistance at 20°C –5...+40°C (non adjust.) “ Data Sheet 1.030 This sensor range is designed for use with controllers to provide relative humidity measurement and temperature control in ventilation systems. **NIST Certified 5573Ω Sensing range DDU 0001 Fan Coil Unit Return Air Temp. Sensors DDH, DDTH Resistance at 20°C INSTALLATION DETAILS Sensing element - Negative temp. coefficient thermistor Wiring - 2 wire non-polarised low voltage dc (safety extra low voltage SELV) Protection class - IP 65 DDU 0001, 1803 Duct Humidity/ Temperature Sensors Associated actuators: ALE, ALES, ARE, ARES, AVE, AVUE, ALi This sensor range is designed for use with controllers to provide relative humidity measurement and temperature control in ventilation systems. DRH, DRTH Adjustable scale Min 100mm, max 330mm infinitely variable between limits Compatible controllers: CSC, CXR, CXT, CZT, CZU, IAC, KMC, MMC, MicroNet, BAS, Sigma FEATURES • Simple fixing (direct or spring clip) • Compact size • 1.5m fly lead Associated controllers: MMC and IAC (reset or low limit) Associated actuators: ALE, ALES, ARE, ARES, AVE, AVUE, ALi Stem length –5...+100°C Data Sheet 1.003 FEATURES • Very fast response to temperature changes • Stylish design has easily removable screw lid • Simple wiring connections • Simple commissioning • Variable probe length (covers many applications) • Optimum sensing position can be easily set • Simple replacement of existing sensors Temperature sensors specifically designed for use in return air space of terminal units. Sensing range 0...40°C INSTALLATION DETAILS Sensing element - Negative temp. coefficient thermistor Output - 1 reversible 0...10Vdc signal (heating or cooling), 1 fixed 10Vdc output. Proportional band - 2...15K Power supply - 24Vac (+/–10%) 50/60Hz Protection class - IP 20 Sensors incorporate fan speed control switches. These devices are used for the control of temperature zones in buildings, such as hotel bedrooms or individual offices, which are air conditioned by fan coil units. Can be used with any 0...10V actuator. DRTE Adjustable scale none Sensing range DDT 0001 DDP 3601 Fitting Kit PRODUCT SELECTION Satchwell Sensors Duct Temperature, Temperature/humidity, Carbon Dioxide & Pressure Sensors DDCO Infrared Analyser CO2 Sensor Measurement Repeatability Operating range (selectable) temp. Input voltage Analogue output (selectable) 20...30V ac/dc 0...5Vdc, 0...10Vdc or 4...20mA The DDCO is a non-dispersive infrared analyser designed for measuring environmental CO2 concentration in ventilation systems and indoor living spaces. Its measurement range of 0...2000 or 0...5000 ppm covers the range required to monitor compliance with ASHRAE or other ventilation efficiency standards. DDCO 2602 An LCD display is available to provide local indication of CO2 concentration and facilitate the setup and calibration process. An adjustable setpoint relay is available for direct control and alarm applications. Microprocessor-based digital electronics and a unique self-calibration algorithm improves long-term stability and accuracy. Protection class - IP 65 Accuracy - ±75 ppm Response time - <60 seconds for 90% step change Sensor connection - 2 plastic tubes with inside diameter of 6mm ?????? ±20 ppm 0...50°C This sensor is for use with Satchwell controllers to provide relevant temperature influence on the heating and air conditioning plant, in accordance with prevailing weather conditions. Data Sheet 1.601 The DDV gives a 0...5Vdc output over a range of 0.4...10 m/s. The velocity range may be limited if required to give greater resolution. On its minimum setting the range is approximately 0.4 to 4 m/s. DDV 1201 Output Measuring range (adjustable by min/max knob) 0...5Vdc 0.4...10 m/s (max) 0.4...4 m/s (min) Data Sheet 21.671 Air Velocity Sensor DOT 0002 DOT 0002 Outside Solar Sensor Resistance at 20°C –40...+55°C 5573Ω 12490Ω Compatible controllers: CSC, IAC, KMC, MMC, LIB, MicroNet, BAS, Sigma INSTALLATION DETAILS Sensing element - Negative temp. coefficient thermistor Wiring - 2 wire non-polarised low voltage dc (safety extra low voltage SELV) Protection class - IP 65 The DOS Solar Sensor has particular advantages to combat the specific effect of solar heat gain. Its application is a true benefit to modern glass/translucent buildings where solar gain is a negative influence on comfort and occupant efficiency. Energy savings will be realised by allowing for solar contributions. DOS 0001 Sensing range Data Sheet 1.402 FEATURES • Fully backwards compatible • Small physical size • Simple commissioning Outside Temp. Sensor Associated controllers: IAC, MicroNet, BAS, Sigma INSTALLATION DETAILS Sensing element - Negative temp. coefficient thermistor Wiring - 3 wire (signal, earth and 24Vac power supply) Protection class - IP 41 DDV PRODUCT SELECTION Outside Sensors (cont) 0...2000 or 0...5000 ppm Satchwell Sensors DOS 0001 Sensing range Resistance at 20°C –40...+55°C 5573Ω Data Sheet 1.402 Compatible controllers: CSC, IAC, KMC, MMC, LIB, MicroNet, BAS, Sigma FEATURES • Fully backwards compatible • Small physical size • Simple commissioning INSTALLATION DETAILS Sensing element - Negative temp. coefficient thermistor Wiring - 2 wire non-polarised low voltage dc (safety extra low voltage SELV) Protection class - IP 65 This sensor is used with Satchwell controllers to influence temperature or time control of heating and air conditioning plant in accordance with prevailing weather conditions. DOW 2701 Pipe Temperature Sensors The DST 0001 permits the monitoring and control of fluid temperature through its specially designed thermistor housing. Its simple installation promotes its flexible use for temporary or permanent monitoring/control applications. DST 0001 Water Temp. Sensor (surface) DST 0001 FEATURES • Allows direct mounting to pipe surface, allowing any point to be monitored • Easily fitted, making it perfect for permanent or temporary situations • Simple commissioning Water Temperature Sensor (immersion) Fast Response Water Sensor (immersion) Resistance at 20°C Pipe surface 5573Ω Data Sheet 1.401 INSTALLATION DETAILS Sensing element - Negative temp. coefficient thermistor Output signal - 0...10V signal Power supply - 24Vac Protection class - IP 47 Sensing range Stem length –10...+120°C Min 100mm, max 330mm infinitely variable between limits Resistance at 20°C DOW Wind Sensor Remote Adjustment Units 5573Ω The RPW Unit is used for adjusting the controller’s setpoint from remote site. INSTALLATION DETAILS Sensing element - Negative temp. coefficient thermistor Wiring - 2 wire non-polarised low voltage dc (safety extra low voltage SELV) Protection class - IP 65 Time constant - 7 secs. ACCESSORIES DWA 0001 – Brass Pocket Adaptor DWA 0002 – Immersion Pocket, 120mm, DWA 0003 – Immersion Pocket, 200mm, DWA 0004 – Immersion Pocket, 200mm, DWA 0005 – Immersion Pocket, 120mm, DWT 0002 Scale range RPW 4425 –5...+50°C Data Sheet 1.901 These units are used on various Satchwell temperature controllers to give remote set value adjustment. Compatible controllers: CSC, CXR, CXT, CZT, IAC, KMC, MMC, LIB, MicroNet, BAS, Sigma RPW Remote Setting Unit INSTALLATION DETAILS Indication - Graduated dial Adjustment - Dial Mounting - Suitable for surface or conduit box mounting Protection class - IP 20 stainless steel brass stainless steel brass Sensing range Stem length Resistance at 20°C –10...+120°C 120mm (non adjustable) 5573Ω Data Sheet 1.204 Compatible controllers: CSC, CXR, CXT, CZT, IAC, KMC, MMC, LIB, MicroNet, BAS, Sigma FEATURES INSTALLATION DETAILS • Very fast response to temperature change Sensing element - Negative temp. coefficient thermistor • Small probe diameter for direct insertion into small pipes Wiring - 2 wire non-polarised low voltage dc (safety extra low voltage SELV) • Stainless steel probe Protection class - IP 65 • Simple commissioning Time constant - 2 secs 42 Sensing range –40...+40°C (wind effect zero above 20°C) Compatible controllers: CSC, CXR, CXT, CZT, IAC, KMC, MMC, LIB, MicroNet, BAS, Sigma Data Sheet 1.203 FEATURES • Variable stem length - 100mm to 330mm • Sensor crown ensures good thermal contact with pocket end • Fast response • 120mm brass pocket (DWA 0005) and heat conductive paste supplied as standard • Simple commissioning Control function Wind effect only Data Sheet 1.203 DWT 0001 The DWT 0002 sensor is designed for use in the most demanding control schemes. Many modern applications call for above average performance and this device is key to stability and efficiency. The sensing element is encased in the optimum amount of high quality stainless steel, permitting ultra fast detection of temperature change. DWT 0002 Mounting 5...120°C INSTALLATION DETAILS Sensing element - Negative temp. coefficient thermistor Wiring - 2 wire non-polarised low voltage dc (safety extra low voltage SELV) Protection class - IP 65 Fixing strap - Metal, sufficient for pipes up to 100mm This sensor simplifies product selection and improves control loop performance with its unique probe assembly. The shaft is simply extended and inserted into the pocket, ensuring a good contact. The sensor can be used with a vast range of other manufacturer’s pockets when used in conjunction with the pocket adaptor DWA 0001. The use of the adaptor avoids system drain downs and costly down time. DWT 0001 Sensing range 43 Controlled condition Temperature CZT CXR CXT • For use with controller type MMC KMC IAC MN (300, 440, 500, 620) • • • • PRODUCT SELECTION Satchwell Switches & Thermostats Duct Temperature Thermostats, Pressure and Air Flow Switches These thermostats are for duct applications and incorporate a single pole double throw contact switch. FEATURES • Simple installation and commissioning • Cable gland supplied Satchwell Switches & Thermostats Pipe Temperature Thermostat Sensing range Adjustment Stem type Contact rating TDR 2201 0...60°C Exposed Rigid stem (190mm x 8mm Ø) 230Vac, 16A SPDT TDC 2202 0...60°C Exposed Capillary stem (1 metre) The TSM Thermostat is typically used in water control applications where it is not possible to insert a pocket into the pipe. The thermostat is attached to the pipe by a spring strap (supplied). Data Sheet 21.001 TDR, TDC The SPA 1501…1504 Differential Pressure Switches can be used to signal when the pressure difference is too high due to a blocked filter, too low due to flow failure, or for level control in a pressurised vessel. Suitable for use on a vacuum. SPA Universal Differential and Universal Pressure Switches TSM Protection class - IP 40 Max head temperature - 80°C Air Temperature Thermostats The SPA 1505 &1506 Pressure Switches can be wired into control circuits or contactors to provide a high or low pressure cut-out. Alternatively, they can be wired directly to a bell or light to provide a high or low pressure alarm. Not suitable for use on a vacuum. Spec. no. Sensing range Reset differential* Contact rating Universal Differential Pressure SPA 1501 150 - 1000 mbar 50 - 100 1A @ 250v SPA SPA SPA SPA 1502 1503 1504 1505 6 - 20 mbar 15 - 60 mbar 40 - 200 mbar 120 - 2200 mbar 3-8 5 - 16 20 - 60 110 - 450 1A 1A 1A 6A SPA 1506 1000 - 6000 mbar 200 - 1500 6A @ 250v 250v 250v 250v 250v TCL SFA 1451 Adjustment Contact rating 0...90°C Exposed 230Vac, 16A SPDT Data Sheet 21.003 FEATURES • Simple installation and commissioning • Cable gland supplied Ambient temperature limits - Maximum sensing plate temperature 100°C Maximum pipe diameter - 150mm Protection class - IP 40 Outside and Pipe Frost Thermostats @ @ @ @ Protection class - SPA 1501-1504 IP 65, SPA 1505/1506 IP 54. *Adjustable between (mbar) Max line pressure - SPA 1501 - 20 bar, SPA 1502-1504 - 10 bar, SPA 1505/1506 - 6 bar This switch is designed to control air flow using a paddle to switch on and off the power supply. The paddle can be trimmed if the air flow is above 5 metres per second. Sensing range TSM 2501 Strap-on Pipe Thermostat Type Universal Pressure PRODUCT SELECTION Flow setting Contact rating 1 m/s, 2.5 m/s (paddle untrimmed) 24...230Vac, 15A single pole, double throw The range of TCL Freeze Thermostats covers both outside, heater battery and water pipe freeze protection. Sensing range Type Stem type Contact rating TCL 1601 –15...+10°C – The TCL 1601 wall mounting freeze thermostat is suitable for outside mounting. Outside (auto reset) 230Vac SPDT heating 10A, cooling 3A TCL 1602 –18...+13°C Coil and pipe (manual reset) Capillary stem (6m) 230Vac, 6A SPDT TCL 1603 –18...+13°C Coil and pipe (auto reset) Capillary stem (6m) The TCL 1602 and TCL 1603 have a capillary that will sense the lowest temperature on the face of the battery or the surface of a pipe. Data Sheet 21.004 Air Temperature Thermostats INSTALLATION DETAILS Protection class - TCL 1601: IP 65, TCL 1602/3: IP 43 Data Sheet 21.670 Head protection class - IP 65 SFA Transducer Air Flow Switch The SPA Differential Pressure Switch is used to monitor non-inflammable and non-aggressive gases. Typical applications are filter dirty and fan run/stop detection. ACCESSORY DDP 3601 Fitting Kit (containing 2 metres of PVC tubing and 2 duct mounting pitot tubes) Adjustable range for trip pressure Max. operating pressure Repeatability Contact rating SPA 1401 0.2...3.0 mbar 50 mbar 0.025 mbar 230Vac, 1A SPDT SPA 1402 1.0...10.0 mbar 50 mbar 0.05 mbar EPT Data Sheet 21.601 SPA Electro Pneumatic Transducer Protection class - IP 54 Pressure connection - 2 plastic tubes with inside diameter of 6mm Air Differential Pressure Switch Pipe Temperature Thermostats and Flow Switches The SFW Flow Switch is designed to control water flow, in pipe diameters from 1” to 6”, using a paddle to switch on and off the power supply. The paddle can be trimmed to suit the flow required. It is designed to be mounted in a short necked welded socket or a tee with a short branch. This transducer is used as an interface between an electronic controller and a pneumatically operated control valve or damper. It is set to receive a 0...10Vdc input and converts it to a proportional 0...20 PSI output signal. The input may be configured, if required, for 0...5Vdc or 4...20mA by using the jumpers on the PCB. Max fluid temp. Contact rating 85°C 24...230Vac, 15A single pole, double throw SFW 1251 EPT 7401 FEATURES • Smooth stable linear performance • Choice of input signals to meet most control applications. 0...10Vdc, 0...5Vdc or 4...20mA selected from onboard jumpers • LED indication of supply status and increasing/decreasing pressure signal • Indication gauge for actual air pressure output • Manual override of output pressure signal Water Flow Switch Adjustment 0...90°C Exposed FEATURES • Simple installation and commissioning • Cable gland supplied Data Sheet 21.001 Pocket Contact rating 1/2” NPT (100mm x 8mm Ø) 230Vac, 16A SPDT Protection class - IP 40 Max head temperature - 80°C TWK Water Immersion Thermostat These thermostats are typically used in water high limit/control applications such as HWS cylinders or boilers. The TWL is a manual reset, high limit thermostat with a Single Pole Double Throw (SPDT) action. The TWM is a combined control thermostat and manual reset, high limit thermostat allowing independent setting of both the control point and high limit temperature. TWL, TWM Water Immersion Thermostats (manual reset) Sensing range Adjustment TWL 2302 65...85°C Exposed Pocket NPT (100mm x 8mm Ø) TWM 2401 0...90°C (control) 70...90°C (limit) Exposed Concealed 1/2” NPT (100mm x 16mm Ø) 1/2” Contact rating 230Vac, 16A SPDT Data Sheet 21.002 Protection class - IP 40 Max head temperature - 80°C FEATURES • Simple installation and commissioning • Cable gland supplied • Manual reset • Concealed setting for reset temperature 44 Input power 0...10Vdc 0...5vdc 0...20 psi or 3...15 psi 45 psi 24Vac/dc nominal INSTALLATION DETAILS Indication - Output air pressure gauge (indication only) Power on LED Pressure increasing LED Pressure decreasing LED Head protection class - IP 65 Sensing range Max supply pressure 4...20mA SFW TWK 2301 Output signal Data Sheet 25.021 Data Sheet 21.670 The TWK Thermostat is for water applications and incorporate a single pole double throw contact switch. Input signal 45 PRODUCT SELECTION Satchwell Actuators Zone Valves & Actuators Zonemaster Control System (24Vac) AVU 2201 Zone Valve Actuator (0-10vdz) Zone Valve Actuators Control action Thrust 24Vac Reversing-modulating 105N INSTALLATION DETAILS Stroke - 11.5mm Stroke time - 60 secs Action - Reversing-modulating Associated controllers - CZU, IAC, URC, MN Manual override - Adjusted by means of a screwdriver slot in the top of the cover Protection class - IP 41 FEATURES • Simple installation and commissioning (self stroking) • Direct coupling without the use of tools • Built-in manual operator • Connect up to seven AVU actuators in parallel from one CZU or IAC controller output These actuators operate Satchwell MB valves. The XRM is a modulating actuator for use with Climatronic integral controllers and the MMC controller. The RM is a 230V reversing actuator for two-position control when used with a changeover type thermostat or modulating control when used with an appropriate controller. On power failure the actuator can be operated manually. Power supply Input control Control action Thrust AVE0001 24Vac, 50Hz 0...10Vdc Direct acting 105N AVE0002 24Vac, 50Hz 0...10Vdc Reversing acting 105N INSTALLATION DETAILS Action - Direct or Reverse Acting specifications available Stroke - Approximately 9.5mm Stroke time - 60 secs Associated controllers - DRTE, CZT, IAC, KMC, MMC, URC, MN, BAS, Sigma Associated valves - VEU, MEU, FEU Manual Override - Reset button on underside for use when manual override is operated when AVE is powered up. Protection class - IP 40 FEATURES • Simple installation and commissioning (self referencing) • Direct coupling without use of tools • Built-in Manual Operator and Override Reset • Connect up to 10 AVE actuators in parallel from one controller output The ‘AR’ range of Reversing Actuators have a rotary output for coupling to air dampers or rotary valves requiring a rotary drive through approximately 95°. These can be used for either modulating or ON/OFF control depending on the control signal supplied to the actuator. FEATURES • Normally open and normally closed models available in both 230Vac and 24Vac • Direct coupling to the ZY range of valves without the need for linkage kits • High performance duty for commercial HVAC applications • Positive spring return for fail safe operation • Manual Override Lever • ON/OFF Control Power supply Spring return AY 1201 AY 1251 230Vac 230Vac Normally closed Normally open AY 1301 AY 1351 24Vac 24Vac Normally closed Normally open Rotary Actuators Data Sheet 3.030 INSTALLATION DETAILS Valve running time - Power stroke 9...11 secs, Spring return stroke 4...5 secs Max different pressure - 350 kPa Compatible valves - ZY range of Zone Valves Compatible controllers - IAC, BAS, Sigma and thermostats Manual operation - By means of a lever located on the side of the body Protection class - IP 41 AVUE Valve Actuators (0-10V) These proportional actuators utilise a linear output drive and are used in conjunction with any controller providing a 0...10Vdc output signal. These control valves are applied, typically, to regulate the flow of either hot or chilled water supplying heating or cooling coils in various types of terminal unit, for example fan coils units, reheat coils associated with variable air volume units, also small air handling plants and heat exchangers. Valve Actuators (pulsed) FEATURES • Compact size • Hollow actuator drive output shaft accommodates any length of damper shaft without the need to cut it • Simple to install, most dampers do not require universal joints or rods • Accommodates shaft diameters from 10...20mm and square shafts from 10...16mm square • Stroke limiter supplied with the actuator • Double insulated, no earth required • 0...10V Feedback signal for monitoring the actual actuator position via BMS (ARE only) Input control Control action Thrust 24Vac 0...10Vdc Direct acting 220N AVUE 4354 24Vac 0...10Vdc Reversing acting 220N • Direct coupling to all normal dampers without mounting brackets linkage kits • Positive spring return operation INSTALLATION DETAILS Action - Reversing, modulating Stroke - 12.7mm (1/2”) Stroke time - 150 secs/50Hz, 125 secs/60Hz Associated controllers - DRTE, CZT, KMC, MMC, IAC, URC, MN, BAS, Sigma Associated valves - VEU, MEU, FEU, VZX, MZX Manual operator - By thumb rotation of partially exposed gear wheel Protection class - IP 40 FEATURES • Simple to install. Direct coupling to valve without use of tools • Minimal commissioning. No site adjustments required (self stroking) • Compact size • Built in manual operator 230Vac (5VA) 230Vac/3A Two-position (controlled by changeover thermostat or switch). Also suitable for CSC, CMC. RMS, RXS, RES Spring Return Rotary Actuators Power supply Control action Thrust AVUX 4202 24Vac Reversing-modulating 220N AVUM 4601 230Vac Reversing-modulating 220N ARX 2252 ARX 2253 ARE 2302 ARE 2303 ARE 2304 ARE 2352 ARE 2354 ARE 2355 ARM 2606 ARM 2607 ARM 2656 ARM 2657 24Vac 24Vac 24Vac 24Vac 230Vac 230Vac Input signal Pulsed 24Vac Pulsed 24Vac 0...10Vdc 0...10Vdc Pulsed 230Vac Pulsed 230Vac Torque 15 Nm 8 Nm 15 Nm 8 Nm 15 Nm 8 Nm Start & span 2202 - no 2203 - no 2252 - no 2253 - no 2302 - no 2303 - yes 2304 - yes 2352 - no 2354 - yes 2355 - no 2606 - no 2607 - no 2656 - no 2657 - no Auxiliary switches 2202 - no 2203 - yes 2252 - no 2253 - yes 2302 - no 2303 - no 2304 - yes 2352 - no 2354 - yes 2355 - yes 2606 - no 2607 - yes 2656 - no 2657 - yes Data Sheet 3.215 INSTALLATION DETAILS Action - Reversing-modulating Stroke time - 90...220 seconds Angular stroke - 95° Protection class - IP 54 Position indicator - Marked 0...10 representing 0...100% of the actuator stroke Built-in auxiliary switches Running time (approx) RXS 7254 RXS 7255 LINKAGE LK 2701 LK 2702 LK 2703 LK 2407 LK 2408 KIT ACCESSORIES MBF 3-port Flanged Valves 65...100mm MB 3-port Screwed Valves 1/2”...2” VV Butterfly Valve 2...4” Traditional Connection to Damper Boxes Direct Damper Mounting Kit RES 7354 RMS 7654 RMS 7655 RXS 7256 RXS 7257 RES 7355 RMS 7656 RMS 7657 24Vac 24Vac 24Vac 230Vac 230Vac 24Vac 24Vac 230Vac Pulsed 24Vac Pulsed 24Vac 0...10Vdc Pulsed 230Vac Pulsed 230Vac Pulsed 24Vac 0...10Vdc Pulsed 230Vac 15 Nm 15 Nm 15 Nm 15 Nm 15 Nm 4 Nm 4 Nm 4 Nm - 2 SPDT (3A) - - - 1 SPDT (1.5A) (7657 only) 150s 150s 150s 150s 150s 40...70s INSTALLATION DETAILS Action - Open/close Angular stroke - 95° Protection class - IP 54 Data Sheet 3.005 INSTALLATION DETAILS Action - Reversing, modulating Stroke - 12.7mm Stroke time - 100 secs Associated controllers - CSC, MMC, CXT, CXR, IAC, URC, MN, BAS, Sigma Associated valves - VEU, MEU, FEU, VZX, MZX Manual operator - By thumb rotation of partially exposed gear wheel Protection class - IP 40 ACCESSORY AVUA 1752 Rain Protection Cover 46 RM 3601 Power supply ACCESSORY AVA 1752 Rain Protection Cover FEATURES • Simple to install. Direct coupling to valve without use of tools • Minimal commissioning. No site adjustments required (self stroking) • Compact size • Built in manual operator Integral (controlled by CXT, CXR, CSC, MMC, URC or IAC Data Sheet 3.305/3.310 Data Sheet 3.001 These valve actuators are designed to be used on the VZX two port and the MZX three port valves. The AVUX is a 24 volt ac reversing actuator suitable for modulating the VZX and MZX valves from any 24 Volt ac controller or device. The AVUM is a mains Voltage reversing actuator and can be controlled from any controller or device having a mains switched output. AVUX, AVUM Power supply AVUE 4304 Application 24Vac/0.02A ARX 2202 ARX 2203 These actuators have a rotary output for direct coupling to air dampers. Models are available for on/off Power supply operation from 230V or 24V power supplies. There is also a 0...10Vdc input Input signal version that is fully modulating. Torque FEATURES Mid-sized Actuators Transfer switch 24Vac (0.5VA) INSTALLATION DETAILS Stroke - 90° angular in 4 minutes. Reversing Torque - 2 Nm Associated valves - MB valves (3-port) Actuator position indicator - Marked 0...10 visible from both sides Transfer switches - Two single pole. Not electrically separate Protection class - IP 41 Modulating and Two-position Light Duty Actuators ARX, ARE, ARM Power supply XRM 3201 Data Sheet 3.201 RM, XRM Data Sheet 3.011 The AY range of actuators has been designed for use on the ZY range of Zone Valves in ON/OFF HVAC applications. They mount directly onto the valves without the need for linkages or calibration. Flexibility is provided with the variety of voltages and functions, all making for ease of installation. AY Power supply Data Sheet 3.010 The AVE 24Vac zone valve actuator is designed for use on the Satchwell VEU, MEU and FEU valves and is used in conjunction with any controller providing a 0-10Vdc output signal. The AVE has a linear output and is suitable for use on hot or chilled water applications on terminal units. AVE PRODUCT SELECTION Rotary Actuators The AVU Mk 2, 24Vac Valve Actuator is designed for use on Satchwell zone valves such as the VEU, MEU and FEU. The AVU has a linear output and is suitable for use on hot or chilled water applications on terminal units. The AVU is controlled by the Satchwell CZU, IAC, URC and MicroNet MN controllers. AVU Mk2 Satchwell Actuators 47 2 SPDT 1 SPDT (1.5A) (3A) (7257 only) 150s 40...70s PRODUCT SELECTION Satchwell Actuators Linear Actuators ALi 1576 ALi 1577 ALi 1676 ALi 1677 0...10Vdc feedback No Yes No Frame Standard Short Short Standard Power supply Input signal The ALi has several modes of operation, from start and span settings to reverse acting including two safety modes. It incorporates a manual override with a gear train disengagement feature by means of a manual operation key located on top of the case. Intelligent Linear Actuators 0...10Vdc, 0...4Vdc, 6...10Vdc, 2...10Vdc (safety mode) 700N Running speed ZY 1 s/mm Max stroke 38mm 38mm Auxiliary switches 25mm 25mm Use kit ALA 1211 (2 x 5A, 250V adjustable) 2 and 3-port Zone Valves INSTALLATION DETAILS Stroke - 0...38mm max (11/2”) Associated controllers - CZT Mk 5 (separate transformer required), IAC, KMC, MMC, MN 440, MN 500, MN 620, URC, BAS, Sigma Associated 2-port valves - VSF, VZF, VZ Associated 3-port valves - MJF, MZF, MZ Type of operation - Reversing, modulating Protection class - IP 54 Drive - Operates on screw-jack principle. Ultra reliable Spindle coupling - Freely rotating coupling, screwed 3/8” (24UNF) Manual operator and override - Hand operator with gear train disengagement failure Satchwell Linear Actuators type ‘AL’ are reversing actuators having a linear output, for direct coupling to Satchwell lift and lay seattype control valves or other seat valves requiring a linear driver over stroke lengths of up to 38mm (11/2”), within the limits of output thrust and with compatible mounting arrangements. Linear Actuators The ALE actuator can be set to operate a low hysteresis when used for tight control applications on microprocessor based controllers such as the KMC and MMC. FEATURES • Direct coupling to Satchwell and third party valves • Universal for valve strokes, up to 38mm (11/2”). Actuator stroke is self-setting to suit valve stroke • Alternative stroke times, to suit application • Standard or low hysterisis selection on ALE types ALX 1201 Frame Power supply Input signal Thrust Running speed Max stroke Auxiliary switches ALX 1251 ALE 1302 Standard Short 24Vac 24Vac Pulsed 24Vac Pulsed 24Vac ALE 1352 ALM 1601 Standard Short Standard 24Vac 24Vac 230Vac 0...10Vdc 0...10Vdc Pulsed 230Vac 538N 311N 538N 311N 538N 8.5 s/mm 5.0 s/mm 8.5 s/mm 5.0 s/mm 8.5 s/mm 38mm 16mm 38mm 16mm 38mm Use kit ALA 1211 1 x 5A, 250V fixed, built-in Use kit ALA 1211 1 x 5A, 250V fixed, built-in Use kit ALA 1211 ALXS, ALES, ALMS Spring Return Linear Actuators Accessories for ‘AL-’ Type Actuators The ALES actuator can be set to operate a low hysteresis when used for tight control applications on microprocessor based controllers such as the CZT, KMC and MMC. FEATURES • Positive power failure operation • Patented maintenance free air brake system • Spring return action to ‘spindle retracted’ or ‘spindle extended’ position • Direct coupling to Satchwell and third party valves • Universal for valve strokes, up to 25.4mm (1”). Actuator stroke is self-setting to suit valve stroke • Standard or low hysteresis selection on ALES types 2, 3 and 4-port Unit Valves 1/2” 3/4” 1/2” 3-port BSP (female), parallel fitting 1/2” 1/2” 3/4” 3/4” 3/4” Cvs Max ∆p (kPa) 1201 1202 1203 1204 1205 1206 1.0 2.6 3.6 3.6 5.2 7.3 350 350 350 175 175 175 AY AY AY AY 1201 1251 1301 1351 – – – – 230Vac NC 230Vac NO 24Vac NC 24Vac NO ZY ZY ZY ZY ZY ZY 1301 1302 1303 1304 1305 1306 1.0 2.6 3.6 3.6 3.6 7.3 350 350 350 175 175 175 AY AY AY AY 1201 1251 1301 1351 – – – – 230Vac NC 230Vac NO 24Vac NC 24Vac NO Data Sheet 4.001 This range of characterised Plug and Seat Control Valves for operation by AVU actuators and principally for use in conjunction with the CZU temperature controller, IAC controllers and MicroNet MN controllers. The valves are designed to regulate the flow of hot or chilled water to air heaters and coolers in fan coil units, induction units, small hot water re-heaters associated with V.A.V units or other similar types of terminal unit for the control of room temperature. Size Type Flow 1/2” 2-port BSP (male), parallel fitting 1/2” 1/2” 3/4” 1/2” 3-port BSP (male), parallel fitting 1/2” 1/2” 3/4” FEATURES • Small compact unit valves • Wide range of Kv/Cv values • Long plug travel improves performance and reduces the risk of blockage • Direct coupling actuators 3/4” 4-port BSP (male), parallel fitting The ZVX 2-port Flow Control and 3-port Diverter Valves are for the regulation of low pressure heating and chilled water circuits where on/off control is required. FEATURES • Complete compact unit; no site assembly required • Two-wire control with positive spring return ZVX ALXS 1201 ALXS 1251 ALES 1302 ALES 1352 Power supply 24Vac 24Vac 24Vac 24Vac ALMS 1601 ALMS 1651 230Vac 230Vac Input signal Pulsed 24Vac Pulsed 24Vac 0...10Vdc 0...10Vdc Pulsed 230Vac Pulsed 230Vac 2 and 3-port Zone Valves Compatible actuators ZY ZY ZY ZY ZY ZY Cvs Bypass INSTALLATION DETAILS Valve type - Paddle Power supply - 230Vac, 50Hz Operation - 2-port valve: NC, 3-port valve: Port A is NC Pipe connections - BSP parallel female or compression (includes nuts and olives) Temperature limits Max internal pressure (kPa) VEU VEU VEU VEU 4414 4415 4416 4626 0.63 1.0 1.6 4.0 – – – – 2...120°C 2200 MEU MEU MEU MEU MEU 4422 4423 4425 4626 4627 0.63 1.0 2.0 4.0 6.0 – – – – – 2...120°C 2200 FEU FEU FEU FEU FEU FEU FEU FEU 6414 6415 6416 6451 6452 6454 5626 5627 0.63 1.0 2.0 0.63 1.0 2.0 4.0 5.6 0.5 0.7 1.4 0.5 0.7 1.4 2.8 4.0 2...120°C 2200 1/2” 1/2” 1/2” 15mm 15mm 15mm 3/4” 3/4” Data Sheet 4.101 INSTALLATION DETAILS Action - Reversing-modulating Stroke time - 5 sec/min minimum (see data sheet for other actuator/valve stroke times) Protection class - IP 54 Associated controllers - ALX: MMC, CXR, CSC, CXT, IAC, MicroNet, URC ALE: MMC, KMC, CZT, MicroNet, IAC (sensors DRTE, DDTE, DWTE), BAS, Sigma ALM: CSC Associated valves - See valve data sheets Drive - Operates on screw-jack principle Spindle coupling - Freely rotating coupling, screwed: 3/8” 24-UNF, female (ALM 1601, ALX 1201, ALE 1302), 1/4” 32-UNEF, female (ALX 1251, ALE 1352) Thrust 1/2” 3/4” FEATURES • Suitable for chilled and hot water applications, up to 50% glycol • Range of actuators available for direct connection • 100% tight shut-off INSTALLATION DETAILS Power supply - 24Vac International pressure rating - PN 22 Data Sheet 3.401 ACCESSORIES - see below ‘AL-S’ Actuators are power failure return types having a linear output, for direct coupling to Satchwell lift and lay seat-type control valves. They are also suitable for other seat valves requiring a linear drive over stroke lengths of up to 25.4mm (1”), within the limits of output thrust, with compatible mounting arrangements and spindle projections. VEU, MEU, FEU Type 1/2” 3/4” INSTALLATION DETAILS Pipe connections - BSP parallel female Operating pressure limits - 300 PSI - PN20 (2,100kPa) Seat leakage - 100% tight shut-off - (zero leakage) Valve type - Paddle action Data Sheet 3.601 FEATURES • Self-stroking • Various operating modes • Direct coupling to Satchwell and 3rd party seat valves • Electronic control of thrust under stall conditions • LED indication of actuator status • Safety modes in the event of controller failure reducing software engineering • Selectable resolution 200 or 25 steps • No need to re-stroke after power failure • 0...10V feedback (ALi 1577 & 1677) Size 2-port BSP (female), parallel fitting It is imperative that the valves be piped so that the paddle closes against the direction of the flow. 34Vdc or 24Vac Thrust The ALi has the ability to provide a 0...10V feedback signal for monitoring purposes. This range of Zone Valves are designed to be used with the AY range of actuators. The use of these valves in open systems is not recommended. Yes ACCESSORIES - see below ALX, ALE, ALM PRODUCT SELECTION Small Valves The Satchwell ALi is an Intelligent Linear Actuator providing a modulating output for the control of two and three port seat valves with a stroke of up to 38mm (11/2”). It is selfstroking, automatically adjusting for any valve within the stroke range. ALi Satchwell Valves (fittings not provided) Size Type Cvs Temperature limits Max differential (kPa) 2-port BSP (female), parallel fitting 1/2” ZVX 4201 ZVX 4202 ZVX 4203 3.2 4.5 5.8 5...110°C 200 150 100 3-port BSP (female), parallel fitting 1/2” ZVX 4301 ZVX 4302 ZVX 4303 3.8 5.8 5.8 5...110°C 200 200 200 ZVX 4401 5.8 5...110°C 200 3/4” 1” 3/4” 1” 3-port 22mm compression fitting Data Sheet 24.001 311N Running speed Spring return speed Max stroke Auxiliary switches 7 s/mm These valves are designed to control heating/cooling coils in terminal units such as fan coils and reheat coils. 0.3 s/mm 25.4mm The thermo-electric actuator is suitable for either on/off or pulse width modulation operation. 2 x 5A, 250V fixed, built-in Data Sheet 3.501 INSTALLATION DETAILS Action - Reversing-modulating Stroke time - 8.5 sec/min minimum (see data sheet for other actuator/valve stroke times) Spindle coupling - Freely rotating coupling, screwed: 3/8” 24-UNF, female, adaptor to 1/4” 32-UNEF, female, supplied fitted Protection class - IP 54 Associated controllers - ALXS: MMC, CXR, CSC, CXT, IAC, MicroNet, URC ALES: MMC, KMC, CZT, MicroNet, IAC (sensors DRTE, DDTE, DWTE), BAS, Sigma ALMS: CSC Associated valves - VZ, MZ, VSF, MZF, VZF, MJF (up to 25mm stroke) Size VEX, MEX, FEX, AVX, AVM 2, 3 and 4-port Electro-thermic Valves FEATURES • Small compact valves particularly suitable for mounting in small enclosures • Fly lead for easy electrical connection INSTALLATION DETAILS Power supply - AVX: 24Vac ±10%. AVM: 230Vac ±10% Thrust - 110N International pressure rating - PN16 Protection class - IP 44 Operation - On/off pulse width modulation Associated devices - AVX - IAC, BAS, Sigma AVM - Thermostats and time clocks 48 49 Cvs Temp. limits 2-port BSP (male) 1/2” VEX 7201 0.2-1.9 4...100°C 3-port BSP (male) 1/2” MEX 7301 4-port BSP (male) 1/2” Data Sheet 24.020 Auxiliary switches – ALA 1211 Available for internal mounting. Two voltage-free change-over switches rated 5A, 250V Spindle adaptor – LNK 1402 1/4” 32-UNEF female x 3/8” 24-UNF male. One supplied with each actuator, except ALX 1251 and ALE 1352, for which it is not required Rain protection cover – ALA 1751 Type FEX 7401 1.7 1.7 4...100°C 4...100°C Mode Max. diff. pressure (bar) AVX 7201 AVX 7251 AVM 7301 AVM 7351 (NO) (NC) – 7 7 2.5 Mix 2.5 Divert 3 7 Mix 2.5 2.5 Divert 3 7 (fittings not provided) PRODUCT SELECTION Satchwell Valves 2-port Valves 3-port Valves Size These seat valves are of ‘Globe’ construction with a linear moving spindle and equal percentage characterised plug which closes against the seat when the spindle is lifted. 2-port Seat Valves VZ, VZF, VSF 2-port Seat Valves 1/2” VZX Screwed, bronze The valves are suitable for the control of hot or chilled water and brine or glycol solutions within their limits – see data sheet. They are suitable for operation by the AVUX, AVUM and AVUE actuators only. VZX Satchwell Valves & Linkage Kits 3/4” 1” 11/4” 1 1 /2” 2” INSTALLATION DETAILS Pipe connections - Screwed BSP to BS 21 female – taper Screwed BSP to BS21 female - parallel Characteristic - Equal percentage Rangeability - 50:1 International pressure rating - PN16 Data Sheet 4.401 These seat valves are of ‘Globe’ construction with a linear moving spindle and equal percentage characterised plug which closes against the seat when the spindle is lifted. They are suitable for the control of hot or chilled water, steam, brine or glycol solutions within their limitations – see data sheet. Size Type VZX VZX VZX VZX VZX VZX 4404 4451 4501 4551 4601 4651 Cvs Stroke Max ∆p pressure (kPa) Temperature limits 2 4 8 12 20 32 12.7mm 1180 720 340 200 120 60 2...120°C MZ, MZF, MJF 3-port Seat Valves 1/2” VZ Screwed bronze Cvs Stroke Max ∆p Temperature limits pressure (max internal (kPa) pressure kPa) 1401 1402 1403 1404 1451 0.2 0.5 1.0 2.0 4.0 9.5mm 3/4” VZ VZ VZ VZ VZ INSTALLATION DETAILS Pipe connections - Screwed BSP to BS 21 female - taper Screwed BSP to BS 21 female - parallel Flanged BS 4504 16/11. = DIN 2533 ND 16 Control medium - Brine, 15% max. NaCl or CaCl2 (freeze protection), Glycol solution, 25% max. (freeze protection) International pressure rating - PN16 MJF Flanged cast iron 2...130°C at (1500 kPa) or 2...120°C at (1600 kPa) – – – – – 1” 11/4” 1 1 /2” 2” VZ VZ VZ VZ 2501 2551 2601 2651 8 12 20 32 15.9mm 970 580 410 240 2...200°C at (1300 kPa) or 2...120°C at (1600 kPa) 823-2-801 ” ” ” 15mm 15mm 15mm 15mm 15mm VSF VSF VSF VSF VSF 2426 2427 2428 2429 2430 0.63 9.5mm 1.0 1.6 2.5 4.0 1600 1600 1600 1600 1600 “ – – – – – 20mm 25mm VSF 1476 VSF 1526 6.3 15.9mm 10 1600 1170 “ – 823-2-801 32mm 40mm 50mm VSF 1576 VSF 1626 VSF 1676 16 25 40 640 400 240 “ 823-2-801 ” ” 65mm 80mm 100mm VZF 1727 VZF 1777 VZF 1852 63 25.4mm 80 125 140 100 50 “ – – – 125mm 150mm VZF 1902 VZF 1954 200 315 28 18 “ – – 1/2” VSF Flanged SG iron VSF Flanged cast iron 24.5mm 38mm MZF Flanged cast iron Spring access. kit 1600 1600 1600 1600 1600 1/2” 1/2” INSTALLATION DETAILS Pipe connections - Screwed BSP to BS 21 female - taper Screwed BSP to BS 21 female - parallel Flanged BS 4504 16/11 = DIN 2533 ND 16 Face to Face dimension to DIN 3300 International pressure rating - PN16 Type Max ∆p Temperature limits pressure (kPa) (max internal pressure kPa) Size Type Cvs Stroke 1/2” MZ 3402 MZ 3452 2.5 4 9.5mm 1600 1600 1” 11/4” 11/2” 2” MZ MZ MZ MZ 3501 3551 3601 3651 8 12 20 32 15.9mm 970 580 410 240 15mm 15mm MJF 3426 MJF 3427 1.0 4.0 9.5mm 1600 1600 20mm 25mm MJF 3476 MJF 3526 6.3 10 15.9mm 1300 850 32mm 40mm 50mm MJF 3576 MJF 3626 MJF 3676 16 25 40 24.5mm 550 350 220 65mm 80mm 100mm MZF 3729 MZF 3779 MZF 3854 63 80 125 25.4mm 140 100 50 125mm 150mm MZF 3904 MZF 3958 200 315 38mm 28 18 3/4” 2...200°C at (1300 kPa) or 2...120°C at (1600 kPa) 2...200°C at (1300 kPa) or 2...120°C at (1600 kPa) 2...200°C at (1300 kPa) or 2...120°C at (1600 kPa) Data Sheet 4.610 Satchwell Actuators to Satchwell Valves and Dampers LK 2701, 2702, 2703, 2408, 2407 RM, XRM, ARM, ARX, ARE Actuators to ... Valve type Suitable actuators Linkage kit Comprises Valve type Suitable actuators Linkage kit Comprises MB Valves 1/2”...2” RM, XRM None require – Dampers LK 2407 (866-2-407) ARM 2657 ARX 2253 ARE 2354 LK 2702 (826-2-702) Bracket 2 x screws Output shaft adapter MBF Valves 65...100mm ARM 2607 ARX 2203 ARE 2304 LK 2701 (826-2-701) Bracket Actuator crank with pin Valve crank with slot and manual override lever ARM 2607 ARX 2203 ARE 2304 ARM 2657 ARX 2253 ARE 2354 Bracket Output shaft Adjustable crank Universal coupling Universal coupling for damper LK 2408 (866-2-408) Anti-rotation bracket Stroke limiter VV Valves 2...4” ARM 2607 ARX 2203 ARE 2304 LK 2703 (826-2-703) Bracket, linkage, screws and spring ARM 2607 ARX 2203 ARE 2304 ARM 2657 ARX 2253 ARE 2354 Data sheet 5.001 Data sheet 5.001 Data Sheet 4.410 Satchwell Actuators to Third Party Valves 3-port Valves These 3-port Rotary-shoe Type Valves are characterised for use as mixing or diverting, with hot or chilled water, in heating, ventilating and air conditioning applications. Size ACCESSORIES Reconditioning Kits 617-9-410 MB 1/2...1” 617-9-411 MB 11/4” 617-9-412 MB 11/2” 617-9-413 MB 2” Cvs Max internal pressure (kPa) Temperature limits (kPa) 1402 1452 1502 1552 1602 1652 1.8 4.0 8.0 12.0 20.0 32.0 1000 2...120°C 65mm MBF 4732 80mm MBF 4782 100mm MBF 4857 63 80 120 600 1.8 4.0 8.0 12.0 20.0 32.0 1000 1/2” MB 3/4” Screwed BSP parallel 1” female 11/4” 11/2” 2” INSTALLATION DETAILS Pipe connections - Screwed parallel (female) BSP to BS 21 Flanged BS 4504, Table 6/11 International pressure rating - MB: PN10, MBF: PN6 MBF Flanged 1/2” MBX 3/4” Screwed BSP parallel 1” female 11/4” 11/2” 2” 618-9-510 MBF 65mm 618-9-511 MBF 80mm 618-9-512 MBF 100mm 3-port Rotary Valves Type MB MB MB MB MB MB MBX MBX MBX MBX MBX MBX 4401 4451 4501 4551 4601 4651 LNK LNK LNK LNK LNK LNK LNK 2...120°C LS01 HW01 FS01 FS02 HY01 HY02 IN01 2...110°C Data Sheet 4.501 & 4.502 These ‘Globe’ construction valves are suitable for the control of hot or chilled water and brine or glycol solutions within their limits - see DS 4.601. They are suitable for operation by the AVUM, AVUX and AVUE actuators only. 3-port Seat Valves MZ Screwed bronze ACCESSORIES Replacement Gland Kits 626-9-203 MZ, MJF 626-9-311 MZF VZF Flanged cast iron MZX (cont) These ‘Globe’ construction Seat Valves are suitable for the control of hot or chilled water and brine or glycol solutions within the limits below. ACCESSORY 626-9-204 Replacement Gland Kit ACCESSORIES Replacement Gland Kits 626-9-203 VZ, VSF 15, 20 & 25mm 667-9-201 VSF 32...50mm 626-9-311 VZF Spring Accessory Kit 823-2-801- Available for use in conjunction with ALM 1601, ALX 1201, ALE 1302, to increase maximum differential pressure. MB, MBF, MBX PRODUCT SELECTION Size MZX Screwed BSP bronze INSTALLATION DETAILS Pipe connections - Screwed BSP to BS 21 female - taper Screwed BSP to BS 21 female - parallel Control medium - Brine, 15% max. NaCl or CaCl2 (freeze protection), Glycol solution, 25% max. (freeze protection) International pressure rating - PN16 1/2” 3/4” 1” 11/4” 11/2” 2” Data Sheet 4.601 ACCESSORY 626-9-204 Replacement Gland Kit 50 Type MZX MZX MZX MZX MZX MZX 4402 4452 4501 4551 4601 4651 Cvs Stroke Max ∆p pressure (kPa) Max internal pressure (kPa) Temp. limits 2.5 4 8 12 20 32 12.7mm 1180 720 340 200 120 60 1600 2...120°C ALX, ALE, ALM, ALi Actuators* to ... Valve type Linkage kit Comprises Landis & Staefa VVF and VXF 20mm valve stroke LNK LS01 – Honeywell V5011A 20mm valve stroke LNK HW01 – Fisher Y body 3/4”...11/2”, A body 11/2” Y body 2”...3”, A body 2”...4” LNK FS01 LNK FS02 – – Hymatic 1700 3/4”...11/2”, 1450 11/4”, 1400R 11/2” 1400R 2”...3”, 1700 2”...3” LNK HY01 LNK HY02 – – Siebe VB valves up to 2” LNK IN01 – Data sheet 3.601 * Not ALX 1251 and ALE 1352 Transformers If mains voltage electricity supply is available locally, e.g. at a fan coil unit, it is convenient to use one transformer for each control system. If mains supply is not available locally it may be more convenient to use a larger central transformer. TR1 TR2 TR3 TR4 TR5 Two fly leads are provided for the primary and secondary electrical connections, for ease of installation. 230Vac/24Vac Isolating Transformers Code Size 871-1-201 871-1-202 871-1-203 871-1-204 871-1-205 25VA 50VA 80VA 200VA 300VA Data Sheet 25.001 These transformers conform to EN 60742. 51 INSTALLATION DETAILS Primary - 230V, 50/60 Hz Secondary - 24V r.m.s. Electrical connections 3-core input (fly lead) cable, 0.5m long 2-core output (fly lead) cable, 0.5m long PRODUCT SELECTION Satchwell Linkage Kits & Spares PRODUCT COMPATIBILITY CSC Controller Spares Actuators Satchwell Controllers & Sensors MMC Controllers DRT DRT DWT DWT DST DOT 3451 3453 0001 0002 0001 0002 PCB Board Model Description Part number Data sheet ALE ALES Circuit board ” 477-9-241 477-9-241 3.401 3.501 Adjustable scale Location Spec. no. Time control Compensators CSC 5252 None CSC 5352 Controllers exp. none none none none none room room imm. imm. clamp outs. Adjustable scale Location Spec. no. Output 230V or 24Vac Digital Data sheet DS 2.021 Product Selection - page no. DRT 3453 none room Control Batteries Model Model Description Part number Data sheet CSC SVT Analogue T/S ” 561-9-260 561-9-260 2.021 2.001 CSC SVT Digital T/S ” 561-9-261 561-9-261 2.021 2.001 ● ● ● ● ● ● ● ● ● ● ● ● 39 39 42 42 42 43 CMC 1 CMC 3 – – – CSMC 3 – – – MMC 2 – – – MMC 3 – – – SMT SVT – – – – – – – Part number Micro Management Controller with built-in time schedules MMC 4701 –40...150°C Pulsed ● ● ● 24V or 0...10Vdc 561-9-220 563-9-231 563-9-231 563-9-231 563-9-231 563-9-231 588-9-210 – – – – – – 2.001 Adjustable scale Location Spec. no. Time control Optimisers SVT 4201 Analogue Data sheet 851-2-401 – Adjustable scale Location none none none none none none none exp. room room imm. imm. clamp outs. outs. room Spec. no. 230V on/off Digital Control none room Valves Adjustable scale Location Spec. no. Lug Nuts Part number 626-9-313 626-9-312 valves 21/2”...6” valves DOT, DOS none outs. DOW 2701 none outs. RPW 4425 exp. room ● ● ● ● ● ● ● ● ● ● 42 42 43 43 43 Control Climatronic CXT 5605 –10...120°C Data sheet – – ● (included) Data sheet DS 2.701 Product Selection - page no. 39 39 42 42 42 43 43 41 43 DRT 3451 exp. room DRT 3453 none room DRT 3801 exp. room DRT 3851 exp. room DDT 0001 none duct DDU 0001 none duct DDU 1803 none duct ● ● ● ● ● ● ● 39 39 40 40 41 41 41 CZU Controller exp. none exp. none none none none exp. room room room duct imm. imm. clamp room Adjustable scale Location Spec. no. 24V modulating ● ● ● ● CZT 5305 –10...120°C 0...10Vdc ● ● ● ● ● ● ● CXR 5805 –10...120°C ● ● ● ● ● ● ● 39 39 39 41 42 42 42 Data sheet DS 2.101, 2.105, 2.110 Product Selection - page no. 40 43 Output 24V modulating none duct RPW 4425 exp. room Output DRT DRT DRT DDT DWT DWT DST RPW 3451 3453 3651 0001 0001 0002 0001 4425 1/2”...2” 41 ● (included) CXT, CZT, CXR Controllers Description 39 Micro Management Controller with built-in time schedules MMC 4701 20...90%rh Pulsed ● ● ● 24V or 0...10Vdc Output Product Selection - page no. Part number 39 DRTH DDTH DR DRT DWT DWT DST DOT DOS RPW 3253 3453 0001 0002 0001 0002 0001 4425 Pockets Description DST 0001 none clamp Output Data sheet SVT 4251 (T) Range 125mm immersion DWT 0001 none imm. SVT Controllers Description Sensors Model DDT 0001 none duct District Heating Controller MMC 4601 –40...150°C 0...10Vdc Data sheet DS 2.751, 2.701 Product Selection - page no. Clocks DRT 3651 exp. room Control Output Zonemaster CZU 4201 10...40°C 24V Data sheet DS 2.201 Product Selection - page no. 43 1 MN Controllers (LONMARK®) KMC Controller Replacement Gland Nut and Tube of Grease Kits Model Description Part number Data sheet General notes MEU MJF MZ FEU VEU VJF VSF VZ MZX VZX – – 1/2”...2” valves – – – 15...25mm 1/2”...2” valves 1/2”...2” valves 1/2”...2” valves 623-9-201 626-9-203 626-9-203 623-9-201 623-9-201 626-9-203 626-9-203 626-9-203 626-9-204 626-9-204 4.101 4.610 ” 4.101 ” 4.610 4.110 4.110 4.601 4.101 Adjustable scale Location Spec. no. – series 3 valves Reconditioning Kits Model Description Part number MB 1/2”...1” valves 11/4” valves 11/2” valves 2” valves 617-9-410 617-9-411 617-9-412 617-9-413 4.501 ” ” ” 65mm valves 80mm valves 100mm valves 618-9-510 618-9-511 618-9-512 4.501 ” ” – series 1 & 2 valves MBF Data sheet Control DRT 3453 none room DRT 3451 exp. room DDT 0001 none duct DWT 0001 none imm. DST 0001 none clamp Adjustable scale Location DOT DRTH DDTH RPW 0002 4425 none none none exp. outs. room duct room Data sheet DS 2.101, 2.105, 2.110 Product Selection - page no. ● ● ● ● ● ● ● ● ● 39 39 41 42 42 43 40 41 43 MN MN MN MN MN MN DDU 0001 none duct DOT DOS none outs. DOW 2701 none outs. DRH DRTH none room DDH DDTH none duct ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 39 39 40 33 42 42 43 43 43 40 41 Note 1: MN-S1 is not adjustable, MN-S2/3/4/5 are adjustable URC, BRC Controller MN Controllers (Bus-du-jour®) 1 DU 1 Adjustable scale Location DUS MN-S 1-5 none exp. note1 room room room DDU 0001 none duct DDT 0001 none duct Adjustable scale Location Spec. no. Replacement Gland Assembly, Gland Nut and Tube of Grease Kits Model Description Part number Data sheet General notes MZ MZF VSF VZ VZF 1/2”...2” 626-9-310 626-9-311 667-9-201 626-9-310 626-9-311 4.610 ” ” 4.110 ” 11/13 50 100 150 200 VAV Product Selection - page no. 2 valves 65...150mm 32...50mm 1”...2” valves 65...150mm DST 0001 none clamp Spec. no. Output Keyboard KMC 3201 –40...150°C 0...10Vdc or 0...100% rh DRT DRT DU MN-S DWT 3453 3651/2 4301 1-5 0001/2 none yes none note1 none room room room room imm. – series 1 valves – series 1 valves – series 1 valves Reconditioning Kit Model Description Part number VV 2”...4” valves 618-9-210 Data sheet – DWT 0001/2 none imm. DST 0001 none clamp DDU 0001 none duct DOT, DOS none outs. DOW 2701 none outs. RPW 4425 exp. room DRH DRTH none room DDH DDTH none duct Spec. no. UniFact Pro URC-41 URC-51 ● ● ● ● ● ● ● ● ● ● Bonsai BRC-41 (Pro) BRC-51 (Lite) ● ● ● ● ● ● ● ● ● ● Data sheet DS 10.130 & 4.103 Product Selection - page no. 40 40 33 41 41 MN MN MN MN 300 440 500 620 Product Selection - page no. ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 39 39 43 33 42 42 41 43 43 43 40 41 Note 1: DU 4301 is non adjustable, DUS 4302 and DUSF 4351/4352 are adjustable Note 2: MN-S1 is not adjustable, MN-S2/3/4/5 are adjustable Note 1: MN-S1 is not adjustable, MN-S2/3/4/5 are adjustable 52 DRT DRT DU MN-S 3453 3651/2 DUS 1-5 none yes note1 note2 room room room room 53 24V 8 Types std std Force (N) 538 538 8 ALE 1302 ALE 1352 ALi 1576 1577 24V 0..10V 0..10V 0..10V 24V 24V 24V short std short s.fast* ALi 1676 1677 0..10V 24V s.fast* CvS MB Screwed, BSP parallel, female, rotary shoe (2...120°C max water) 1/2” MB 1402 1.8 ● ● LK2702 3/4” MB 1452 4 ● ● LK2702 1” MB 1502 8 ● ● LK2702 1 ● ● LK2702 1 /4” MB 1552 12 1 ● ● LK2702 1 /2” MB 1602 20 2” MB 1652 32 ● ● LK2702 MBF Flanged, table 6/11, BS 4504, rotary shoe (2...120°C max water) 65mm MBF 4732 63 X X LK2701 X 80mm MBF 4782 80 X X LK2701 X 100mm MBF 4857 120 X X LK2701 X Size X X X X X X MBX Screwed, BSP parallel, female, rotary shoe (2...110°C max water) 1/2” MBX 1401 1.8 ● ● LK2702 3/4” MBX 1451 4 ● ● LK2702 1” MBX 1501 8 ● ● LK2702 ● ● LK2702 11/4” MBX 1551 12 ● ● LK2702 11/2” MBX 1601 20 2” MBX 1651 32 ● ● LK2702 47 47 47 47 47 47 47 47 X NOT compatible Spec. no. 311 538 511 700 230V 24V 0..10V 24V spring spring spring return return return 311 311 700 VZ Screwed, bronze, hot/chilled water, 1/2” VZ 1401 0.2 ● 1/2” VZ 1402 0.5 ● 1/2” VZ 1403 1 ● 1/2” VZ 1404 2 ● 3/4” VZ 1451 4 ● globe ● ● ● ● ● construction, linear movement (2...120°C max water) ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● VZ Screwed, bronze, hot/chilled water, 1” VZ 2501 8 ● 11/4” VZ 2551 12 ● 11/2” VZ 2601 20 ● 2” VZ 2651 32 ● globe ● ● ● ● construction, linear movement (2...200°C max water) ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● VZF Flanged, table 16/11, BS4505, cast 65mm VZF 1727 63 ● 80mm VZF 1777 80 ● 100mm VZF 1852 125 ● 125mm VZF 1902 200 ● 150mm VZF 1954 315 ● iron, globe construction, linear movement (2...200°C max water) ● X ● X ● ● ● ● ● ● X ● X ● ● ● ● ● ● X ● X ● ● ● ● ● ● X ● X ● X X X X ● X ● X ● X X X X Product Selection - page no. 48 ● Direct coupling X NOT compatible 48 48 48 48 48 48 48 * Self stroking, superfast/low hysteresis MZ, MZF Valves ALX 1201 230V 24V Types std std Force (N) 538 538 Input Control Signal Size Spec. no. ALX 1251 ALi 1576 1577 24V 0..10V 0..10V 0..10V 24V 24V 24V short std short s.fast* 311 ALE 1302 538 ALE 1352 511 700 ALi 1676 1677 0..10V 24V s.fast* 700 0..10V 24V spring spring spring return return return 311 311 311 24V Input Control Signal Types Force (N) Size CvS MZ Screwed, bronze globe construction, linear moving spindle (2...200°C max water) 1/2” MZ 3402 2.5 ● ● ● ● ● ● ● ● 3/4” MZ 3452 4 ● ● ● ● ● ● ● ● 1” MZ 3501 8 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 11/4” MZ 3551 12 ● ● ● ● ● ● ● ● 11/2” MZ 3601 20 2” MZ 3651 32 ● ● ● ● ● ● ● ● ● ● ● ● ● ● 48 48 48 48 48 48 48 48 48 Spec. no. AVUX AVUM AVUE AVUE 4202 4601 4304 4354 24V 230V 0...10V 0..10V – – DA RA 220 220 220 220 X NOT compatible ● ● ● ● ● ● VZX Screwed BSP, bronze globe 1/2” VZX 4404 3/4” VZX 4451 1” VZX 4501 11/4” VZX 4551 11/2” VZX 4601 2” VZX 4651 48 Size ALX 1201 230V 24V Types std std Force (N) 538 538 ALX 1251 ALi 1576 1577 24V 0-10V 0-10V 0-10V 24V 24V 24V short std short s.fast* 311 ALE 1302 538 ALE 1352 511 700 ALi 1676 1677 0-10V 24V s.fast* SETH 565-1-601 to 565-1-610 Item Spec. no. Range Current Equipment 574-2-701 45...65% rh ● ● Climatronic CZH 562-3-501 562-3-502 30...55% rh 45...70% rh ● ● ● ● Keyboard 20...80% 20...90% 20...90% 20...90% 20...90% 20...90% 20...90% 20...90% ● ● ● ● ● ● ● ● ● Monotronic ZH KZH 4551 MMC 2401 MMC 2402 MMC 2403 MMC 2451 MMC 2452 MMC 2453 MMC 3701 rh rh rh rh rh rh rh rh Notes 700 230V 46 46 46 Spec. no. No. of steps Switch rating MC and MD MC 1201 MC 1202 MC 1203 MD 3201 MD 3226 6 9 12 5 10 6 Amp 6 Amp 6 Amp 20 Amp 20 Amp 46 TSU 569-2-402 2 Notes ● ● ● ● ● 583-1-551 Size linear moving spindle (2...200°C max ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● – ● – ● ● – ● – ● ● – ● – ● ● steam) ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Spec. no. ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● MEU 3-port unit 1/2” 1/2” 1/2” 3/4” 3/4” valves (2...120°C max water) MEU 4422 0.63 ● MEU 4423 1 ● MEU 4425 2 ● MEU 4426 4 ● MEU 4427 6 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 46 46 46 46 46 46 Product Selection - page no. Product Selection - page no. 48 48 48 48 48 48 48 48 48 valves (2...120°C max water) FEU 6414 0.63 ● FEU 6415 1 ● FEU 6416 2 ● FEU 5626 4 ● FEU 5627 5.6 ● FEU 6451 0.63 ● FEU 6452 1 ● FEU 6454 2 ● ● Direct coupling * Self stroking, superfast/low hysteresis 54 Spec. no. 6 Control X NOT compatible 46 Zonemaster 569-1-201 10...40°C CZU 569-2-201 10...40°C 569-3-201 10...40°C 569-1-202 10...40°C 569-2-202 10...40°C 569-3-202 10...40°C 569-1-203 10...40°C 569-2-203 10...40°C 569-3-203 10...40°C NSU Binary ● CXOC 562-3-713 562-3-715 ● CD 567-1-201 567-2-201 ● ● CSC 561-2-701 561-2-702 561-2-703 561-2-726 561-2-727 561-2-776 561-2-777 ● ● ● Output 24V 24V 24V 24V 24V 24V 24V 24V 24V ● ● Current Equipment ● ● ● ● ● ● ● ● ● The IACs need to be engineered ● CZV 569-2-501 0.4...10 m/s ● TSU 569-2-402 0...10Vdc ● ● Actuator to be replaced with XRM 3201. ● ● ● ● No equivalent available SXC 565-1-217 565-1-218 565-1-219 565-1-220 565-1-223 565-1-224 4201 4301 4202 4302 Used with the C4X and C5X system. Change complete system to CSC. * If original actuator is to be used and it is a K or P series than a transformer must be supplied with the compensator. ● ● ● ● ● ● ● 573-1-201 573-1-251 573-1-276 CSC CSC CSC CSC If original actuator is ALXS then a separate transformer is required. No direct replacement Use MMC and associated detectors/sensors. See above remark*. Replace C7W and C7P detectors/sensors. ● ● ● ● ● No direct replacement Refer to Customer Care Centre or your local sales engineer. See above remark*. Replace detectors/sensors. ● ● ● ● ● ● ● CMC CMC 3803 No direct replacement CSMC CSMC 3804 CSMC 3805 No direct replacement Optimiser Controllers Notes Item Remarks ● ● 569-1-501 0...250mm 0.5 + 569-2-501 H2O 10Vdc ● ● If original actuator is to be used and it is a K or P series then a transformer must be supplied with CSC compensator. Product Selection - page no. 35 35 The CZU 4201 must be installed adjacent to the fan coil unit with a DRT 3451 if temp adjustment from the room is required. CZP ● ● RR XC10 C7 CSC 38 39 36 569-1-401 0...10V dc 569-2-401 to reset CZU Product Selection - page no. 562-3-704 562-3-707 562-3-710 565-1-221 565-1-222 565-1-225 Zonemaster & Temperature Controllers Item Mark 5 CSC's can use existing sensors. Remarks Note: The FLS requires a 0...10 volt dc control signal. ● 5 Amp CvS valves (2...120°C max water) VEU 4414 0.63 ● VEU 4415 1 ● VEU 4416 1.6 ● VEU 4626 4 ● FEU 4-port unit 1/2” 1/2” 1/2” 3/4” 3/4” 15mm 15mm 15mm 48 AVUX AVUM AVUE AVUE AVE AVE 3202 3601 3304 3354 0001 0002 24V 230V 0..10V 0..10V 0..10V 0..10V – – DA RA DA RA 220 220 220 220 105 105 VEU 2-port unit 1/2” 1/2” 1/2” 3/4” MJF Flanged, table 16/11, BS 4504, cast iron globe construction, linear movement (2...200°C max water) 15mm MJF 3426 2.5 ● ● ● ● ● ● ● ● ● ● 15mm MJF 3427 4 ● ● ● ● ● ● ● ● ● ● 20mm MJF 3476 6.3 ● ● ● ● ● ● ● ● ● ● 25mm MJF 3526 10 ● ● ● ● ● ● ● ● ● ● 32mm MJF 3576 16 ● ● X ● X ● ● ● ● ● 40mm MJF 3626 25 ● ● X ● X ● ● ● ● ● 50mm MJF 3676 40 ● ● X ● X ● ● ● ● ● X NOT compatible AVU 2201 24V – 105 ● Calibrator Box CC C4 C4X C5 C5X There is no direct replacement. However, if the controls are being replaced and they are installed within a panel then the FLS may be considered. Remarks 562-3-702 562-3-706 562-3-711 Compensators C6 572-1-276 572-1-376 Current Equipment Notes Alternatively use MMC 4701 and associated detectors/sensors. Response Regulator KZH and KMC terminals are different X NOT compatible Input Control Signal Types Force (N) 0-10V 24V spring spring spring return return return 311 311 311 If KMC/MMC is supplied then actuators to be changed to 0...10V signal 36 37 Product Selection - page no. 24V Remarks Detectors/ sensors to be changed Current Equipment ● ● COC Humidity Controllers Item construction, linear movement (2...120°C max water) 2 ● ● ● ● 4 ● ● ● ● 8 ● ● ● ● 12 ● ● ● ● 20 ● ● ● ● 32 ● ● ● ● ALMS ALXS ALES 1601/ 1201/ 1302/ 1651 1251 1352 CvS VSF Flanged, table 16/11, BS 4504, cast iron, 15mm VSF 2426 0.63 ● ● 15mm VSF 2427 1 ● ● 15mm VSF 2428 1.6 ● ● 15mm VSF 2429 2.5 ● ● 15mm VSF 2430 4 ● ● 20mm VSF 1476 6.3 ● ● 25mm VSF 1526 10 ● ● 32mm VSF 1576 16 ● ● 40mm VSF 1626 25 ● ● 50mm VSF 1676 40 ● ● ● Direct coupling 565-1-501 VEU, MEU, FEU Valves ALM 1601 Spec. no. SEH FBS VSF, MJF Valves 565-1-404 to 565-1-455 Spec. no. Compensators CXC 562-3-701 Refer to Satchwell with full specification of obsolete control and temperature range controller or contact your local sales engineer. Step Controllers * Self stroking, superfast/low hysteresis ● Direct coupling Input Control Signal 48 Duotronic 565 SET CvS Product Selection - page no. ● Direct coupling 576-2-201 to 576-2-458 Item No single direct replacement for these controls however a combination of keyboard or climatronic may be suitable. Product Selection - page no. MZX Screwed BSP, bronze globe construction, linear movement (2...120°C max water) 1/2” MZX 4402 2.5 ● ● ● ● 3/4” MZX 4452 4 ● ● ● ● 1” MZX 4501 8 ● ● ● ● 11/4” MZX 4551 12 ● ● ● ● 11/2” MZX 4601 20 ● ● ● ● 2” MZX 4651 32 ● ● ● ● MZF Flanged, table 16/11, BS 4504, cast iron globe construction, linear movement (2...200°C max water) 65mm MZF 3729 63 ● ● X ● X ● ● ● ● ● 80mm MZF 3779 80 ● ● X ● X ● ● ● ● ● 100mm MZF 3854 125 ● ● X ● X ● ● ● ● ● 125mm MZF 3904 200 ● ● X ● X ● X X X X 150mm MZF 3958 315 ● ● X ● X ● X X X X Product Selection - page no. Duotronic E MZX, VZX Valves ALMS ALXS ALES 1601/ 1201/ 1302/ 1651 1251 1352 230V EC1-2 to EC26-2 IAC 420 ALM 1601 311 CvS 48 Duotronic EC ALMS ALXS ALES 1601/ 1201/ 1302/ 1651 1251 1352 Spec. no. Current Equipment Notes SVT 4201 Product Selection - page no. ● Direct coupling 230V Input Control Signal ALX 1251 Remarks CSC 5352 15 ALX 1201 Compensator Controllers Notes CSC 5252 2 ALM 1601 Current Equipment MMC 4701 2 ARX ARE 2253 2354 24V 0...10V Spec. no. FLS 1502 Spec. no. ARX ARE ARM 2203 2304 2657 24V 0...10V 230V adj span 24V 15 15 8 Item KMC 3201 Size ARM 2607 230V Humidity & Temperature Controllers IAC 420 Types Torque (Nm) XRM 3201 24V OBSOLETE PRODUCTS CZU 4201 Input Control Signal RM 3601 230V VZ, VZF Valves Satchwell Controllers IAC 600 MB, MBF Valves with linkage kits Satchwell Valves & Actuators Optimisers SST 1801 565-1-801 SST 1802 SST 1803 SST 1804 565-1-802 565-1-803 565-1-804 SST 1805 565-1-805 SST 1806 SST 1871 565-1-806 565-1-871 ESS 2202 SMT 1201 588-2-202 587-1-201 ● ● No direct replacement No direct replacement ● ● CMC 3803 561-3-803 CSMC 3804 561-3-804 CSMC 3805 561-3-805 Use relays to cover the 5A rating 37 38 Product Selection - page no. 35 35 55 The detector/sensor is supplied with the SVT but it has no outside detector. ● ● Optimiser/Compensators CMC 1801 561-1-801 CMC 1803 561-1-803 CMC 1826 561-1-826 10Vdc and 15Vdc fixed Remarks SVT 4251 PRODUCT COMPATIBILITY No direct replacement No direct replacement Refer to Customer Care Centre or your local sales engineer. Temperature Controllers Adjustable scale Location ● ● ● ● ● Climatronic 562-3-601 562-3-602 562-3-603 562-3-604 562-4-601 562-4-604 CXT –5...40°C 20...70°C 35...120°C 35...120°C 0...50°C 30...120°C Climatronic 566-1-601 566-1-602 566-1-603 566-1-651 AXT Controller-motor 5...40°C ● 20...65°C 35...120°C 5...40°C ● Climatronic 566-1-301 566-1-302 566-1-303 566-1-351 566-1-352 AZT Controller-motor –5...40°C –5...40°C 35...120°C –5...40°C –5...40°C Climatronic 562-3-301 562-3-302 562-3-303 562-4-302 562-4-303 CZT –5...40°C –5...40°C 35...120°C –5...40°C 30...120°C ● ● ● ● ● ● ● ● ● AZT Controller-motor 10...35°C 10...35°C 10...35°C 10...35°C 10...35°C CXT 5605 can use existing sensors Controller-actuator AET, AEST 568-1-201 10...40°C 568-1-202 10...40°C 568-1-301 10...40°C 568-1-302 10...40°C ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● These controls are controller/actuator combined therefore a replacement actuator will be required. 583-1-801 583-1-601 583-1-001 583-1-401 583-1-251 KET 4201 5...50°C 0...10Vdc 5...50°C 0...10Vdc 331-3-601 331-3-602 DRH 331-3-401 ● Actuators and detectors/sensors to be replaced. If valve fitted check suitable actuator replacement. Direct replacement ABC = 123 ● 331-4-401 7722 DRTH 7723 DDH 331-3-451 ● DDH 3451 uses 15Vdc power supply DDTH 7551 requires 24Vac power supply. ● 331-7-451 Fixing is the same but enclosure size is slightly different. ● 336-1-204 No direct equivalent available DW 1204 Refer to Satchwell or contact your local sales engineer. Detectors/sensors to be changed if MMC being installed. DR 3252 DRT 215-1-601 DDE 331-3-301 DDTE 1601 DWTE 1201 DWTE 1202 Product Selection - page no. 41 41 Adjustable scale Location Spec. no. Range CXR 5805 can use existing sensors 41 300mm – 125mm 200mm 165mm – – – – Product Selection - page no. Item Spec. no. Range 40 DDU 1803 none duct 40 DDT 0001 none duct DWT 0001 none imm. DWT 0002 none imm. DST 0001 none clamp DOT 0002 none outs. DOS 0001 none outs. MMC 4701 can use existing sensors Current Equipment No equivalent replacements Spec. no. Selectable range EPT 7301 0...10Vdc, 0...5Vdc, 4...20mA ● Product Selection - page no. 45 Item/ Voltage Input Spec. no. Current Equipment ● ● 41 41 42 42 42 43 AE 568-1-501 568-1-502 568-1-503 568-1-504 24V 24V 24V 24V 0...10V 0...10V 0...10V 0...10V ● ● ● ● ● ● ● ● AEH 568-1-552 24V 0...10V ● ● ● AES 568-1-601 568-1-602 24V 24V 0...10V 0...10V AEHS 568-1-651 24V 0...10V Item 43 Outside Pilot CP No equivalent available Change complete system to CSC with detectors/sensors. If actuator is XKM or XPM then a transformer must be supplied. ET ZW No equivalent available 325-1-201 325-1-251 325-1-301 323-2-201 323-2-204 323-2-207 No equivalent available ZHO 331-2-701 EO 326-1-303 DP 334-1-201 Limiting Detectors LO 137-1-452 ● ● Product Selection - page no. 35 36 36 36 37 No equivalent available 327-1-202 56 5...60°C LR 167-1-253 20...90°C LZS 315-1-201 10...40°C Remarks When selecting the ‘AL’ range of actuators check size of valve - you may be able to supply the short stroke actuator. ● ● ● ● Other combinations available consult Satchwell. ● ● ● ● When replacement actuators are No direct replacement required please check suitability (ie) shoe or lift and lay valves. ‘P, K, & M’ Series Actuators – 230V/24V ● ● No equivalent available C7W 323-2-501 ● ● ● ● ● ● ● Notes ● CRX CO EPT 7401 yes panel Product Selection - page no. 47 48 48 48 48 48 48 ●* ●* Remarks Detectors C7P 326-2-501 Refer to Satchwell or contact your local sales engineer. 41 ● ● Notes Regulator Thermostats CR ● ● 41 Transducers Spec no. Volt. Pot. Current Equipment Change system. 41 Stem/pocket DDT 1701 –5...+100°C DDU 1801 –5...+40°C DWT 1701 –10...+120°C DWT 1702 –10...+120°C DWT 1801 –10...+120°C DST 1601 5...120°C DOT 2301 –40...+40°C DOT 0001 –40...+55°C DOS 2501 – Controller/actuator combined therefore actuator to be replaced. Product Selection - page no. 339-1-304 DR 3251 Detectors/sensors to be changed if adjustable type. Also if MMC, KMC is installed. ● ‘AE’ Series Actuators – 24V DW 1202 Controller/actuator combined therefore actuator to be replaced. ● 331-3-551 DD 1403 Detectors/sensors to be changed if MMC, KMC is being installed. –125...+250pa –3750...+7500 Requires remounting DD 1401 DWS Selectable range DDP 4201 DDP 4203 Change terminal nos. ● DO 2202 CZT 5305 can use existing sensors Spec. no. LCD display Location DRTH DDH No equivalent replacement Micro Management MMC 2401 –40...140°C MMC 2402 –40...140°C MMC 2403 –40...140°C MMC 2451 –40...150°C MMC 2452 –40...150°C MMC 2453 –40...150°C MMC 3701 –40...150°C Keyboard KZT 4351 DRH Change complete system to KMC or MMC. No direct equivalent available DDTH 331-7-551 Climatronic CZS 562-3-201 MPD 1801 COE 1601 FSS 1001 FSS 1401 FSC 1251 331-3-702 331-3-704 DDH Climatronic AZS Controller-motor 485-1-201 563-1-201 583-1-201 Remarks Item/ Spec. no. Change complete system to CSC or MMC with detectors/sensors. If actuator is XKM or XPM then a transformer must be supplied. Change control system dependant upon existing controls. Refer to Satchwell with full specification number of obsolete control and temperature range of controller or contact your local sales engineer. 'M' Series Actuators 458-1-201 230V 458-1-301 230V No No 'P' Series Actuators PM 453-1-203 230V No SPM – 230V EPM 31 24V 1000Ω ZPM 31 24V 135Ω XPM 31 24V No 'K' Series Actuators KM 454-2-202 230V No Current Equipment Notes Remarks ● ● ● ● N.D.R. N.D.R. ● ● ● Check valve type if replacement actuator can be fitted without valve change as well. SKM 455-2-202 230V 455-2-252 230V EKM 475-2-401 24V 1000Ω SEKM 484-2-401 24V 1000Ω When replacement actuators are required please check suitability No direct (ie) shoe or lift replacement and lay valves. ZKM 475-2-201 SZKM 484-2-201 24V 135Ω 24V 135Ω No direct replacement XKM 474-2-201 SXKM 483-2-201 24V 24V Product Selection - page no. Pot. ● ● ● No No ● ● Current Equipment AM 456-2-201 230V 456-2-401 230V 456-2-402 230V No No No ● ● ● ● AMH 457-2-451 230V No ● ● AMS 457-2-201 230V No 457-2-202 230V No AMHS 457-2-251 230V No Notes ARM not compatible with CMC 3803 ● ● ● ● ● ● ● 47 47 48 48 48 48 48 48 48 N.D.R.= No direct replacement No equivalent available 57 Remarks When selecting the ‘AL’ range of actuators check size of valve you may be able to supply the short stroke actuator. No direct replacement When replacement actuators are No direct required please replacement check suitability (ie) shoe or lift and lay valves. AZM 476-1-401 476-1-402 476-1-451 476-1-801 476-1-851 24V 24V 24V 24V 24V AZ 476-2-401 476-2-451 24V 135Ω 24V 135Ω AZH 476-2-851 24V 135Ω AZS 476-2-401 476-2-451 24V 135Ω 24V 135Ω AXM 476-1-201 476-1-202 476-1-251 24V 24V 24V No No No AX 476-2-701 476-2-751 476-2-201 476-2-251 24V 24V 24V 24V No No No No ● ● ● ● ● ● AXH 476-2-276 476-2-776 24V 24V No No ● ● ● ● ● ● AXS 485-2-201 485-2-251 24V 24V No No AXHS 485-2-276 24V No ALM 477-1-626 230V 477-1-651 230V No No ALX 477-1-226 24V No ALE 477-1-327 477-1-376 24V 24V No No 135Ω 135Ω 135Ω 135Ω 135Ω No direct replacement No direct replacement ● ● ● ● ● When selecting the ‘AL’ range of actuators check size of valve you may be able to supply the short stroke actuator. ● ● ● ● ● ● ● ● ● ● ● No direct replacement ● ● ● ● ● ● ● Product Select. - page no. 47 47 48 48 48 48 48 48 48 47 47 48 48 Replace valve actuator with MB /ARM linkage kit. No No No Volt. DDP DDP DDP DDP 5601 5610 6601 6610 no no yes yes duct duct panel panel LCD display Location Notes DRTH 331-7-501 Detectors/sensors to be changed if MMC, KMC is being installed DRTH 7XXX 8XXX none room * note: DWA 0001 is required Monotronic Balancing Relay (ZC) 581-2-201 Keyboard CMT 1201 FMS 1201 331-2-601 DDH DRH ARE actuator + linkage kit ● ● ● ● ● DRH 7XXX 8XXX none room Spec. no. ZHT DD ● ● ● ● ● ● ● ● ● DDTH 7XXX 8XXX none duct Detectors EH 331-1-401 ● ● ● ● ● ● ● ● ● ● ● ● ● ● Climatronic CXR 562-1-801 562-2-801 562-3-801 562-4-831 10...40°C 562-4-801 10...40°C Actuators must be replaced with a 0...10V type when used with CZT/KMC or multi-stage MMC’s. ● ● CD 567-2-401 Controller-motor AXR 566-1-801 Detectors/sensors to be replaced ‘A’ Series Actuators – 230V/24V Current Equipment ARM 2607 ARX 2203 ALM 1601 ALX 1201 ALX 1251 ALMS 1601 ALMS 1651 ALXS 1201 ALXS 1251 ● ● DDH 7XXX 8XXX none duct OBSOLETE PRODUCTS Pressure Sensors Current Equipment MMC 4701 KMC 3201 CZT 5305 Remarks Item ● 6...40°C 40...110°C Monotronic 574-2-551 6...40°C 574-2-552 20...95°C 574-2-553 45...125°C Climatronic 566-3-001 566-3-302 566-3-304 566-3-352 566-3-354 Notes Sensors, Transducer and Valves ARE 2304 ALE 1302 ALE 1352 ALES 1302 ALES 1352 ALi 1576 ALi 1577 Intronic X 575-1-201 575-1-202 Detectors/sensors Current Equipment CXT 5605 Range CXR 5805 Item/ Spec. no. Satchwell Controllers & Detectors/Sensors ARM 2607 ARX 2203 ALM 1601 ALX 1201 ALX 1251 ALMS 1601 ALMS 1651 ALXS 1201 ALXS 1251 RM 3601 XRM 3201 ALi 1576 ALi 1577 OBSOLETE PRODUCTS Check VA rating. Check if feedback signal is required. 24V ” 4 Nm 8 Nm ZV Actuators 2-port, BSP parallel 1/2” ZV 1201 3/4” ZV 1202 ● ● No direct replacement 1” ● No direct replacement ● Product Selection - page no. 47 47 47 ‘RMV, RXV, REV’ Series Actuators – 230V/24V Current Equipment RMV 7653 230V 12 Nm RMV 7653 ” ” RXV 7253 RXV 7253 24V ” ” ” REV 7353 24V ” Notes Remarks ● ● ● ● ● ● Volt. Pot. 47 47 Current Equipment ● ● No No ERM 472-1-401 472-2-401 24V 1000Ω 24V 1000Ω ZRM 472-1-201 472-2-201 472-1-202 472-2-202 472-1-203 472-2-203 472-3-201 472-3-202 472-3-203 24V 24V 24V 24V 24V 24V 24V 24V 24V 'AR' Series Actuators ARM 473-7-601 473-1-602 473-1-601 ARM 2601 Notes ARX ARE ● ● Remarks When replacement No direct actuators are replacement required please check suitability No direct replacement (ie) shoe or lift and lay valves. 135Ω 135Ω 135Ω 135Ω 135Ω 135Ω 135Ω 135Ω 135Ω No No No No ● ● ● ● ARM 2605 230V ARM 2651 230V No No ● 473-7-201 473-1-202 473-1-201 ARX 2201 ARX 2251 24V 24V 24V 24V 24V No No No No No 473-7-301 473-1-302 473-7-303 473-1-301 ARE 2301 ARE 2351 24V 24V 24V 24V 24V 24V 0...10V 0...10V 0...10V 0...10V 0...10V 0...10V ● ● ● ● ● ● ZV 1303 7.6 No equivalent available ● ● ● ● ● No equivalent available 3-port, compression fitting 15mm ZV 1304 6 22mm ZV 1305 7 28mm ZV 1306 7.6 No equivalent available FEU MK2 (4-Port) 628-2 AVUE Mk2 No No No AVUE Mk1 Yes Yes Yes Current Equipment 6 7 7.6 No equivalent available 3-port, BSP parallel 1/2” ZVX 3301 3/4” ZVX 3302 1” ZVX 3303 6 7 7.6 No equivalent available ● 49 49 49 49 49 49 49 49 49 VEU Mk4 (2-Port) 623-4 Item Spec no. Voltage Signal AVU 478-1-201 24V No 478-2-451 24V – Current Equipment Notes FEU Mk4 (4-Port) 628-4 FEU Mk5 (4-Port) 628-5 VZX MZX (2-Port) 624-4 (3-Port) 626-4 Yes Yes Yes Yes Yes Yes No No No No Yes Yes 24V 0...10V 24V 24V 0...4V 6...10V 478-2-304 478-3-304 24V 24V 0...10V 0...10V 478-1-354 24V 0...10V 478-1-355 478-1-356 24V 24V 0...4V 6...10V 478-2-354 478-3-354 24V 24V 0...10V 0...10V 478-1-201 478-1-202 478-3-202 24V 24V 24V – – – AVUM 478-1-601 478-2-601 478-3-601 230V 230V 230V – – – AVUX MEU Mk4 (3-Port) 627-4 478-1-304 478-1-305 478-1-306 Product Selection - page no. 58 ● Notes construction, linear moving spindle) 2.5 ● ● ● ● ● 5.6 ● ● 8 ● ● 16 ● ● 20 ● ● 50 50 50 50 50 50 ● ● ● ● ● ● ● ● ● ● ● ● ● ● 50 50 50 50 50 50 50 50 50 50 Size Spec. no. CvS MV (Water) 11/4” 11/2” 2” 21/2” 3” 4” 612-1-551 612-1-601 612-1-651 612-1-701 612-1-751 612-1-826 68 100 180 270 470 620 Current Equipment Remarks Notes ● ● ● VV Screwed, BSP parallel female, butterfly on/off, control not tight shut off (2...120°C 2” VV 3651 180 ● No direct VV 3701 270 ● replacement 21/2” 3” VV 3751 470 ● 4” VV 3826 620 ● Product Selection - page no. Remarks Change actuator and linkage. For 11/4” & 11/2” use MB valve and blank off third port. max water) 2” use MB valve, for 21/2”...4” use MBF and blank off third port. CVS value is different and must be checked. 50 50 50 50 50 50 50 2-port Valves continued next page. See notes on VEU, MEU, FEU No replacement and valve/ actuators compatibility below before No replacement specifying replacement actuators. ● ● ● These valves are normally open i.e. lift to open when new valve is fitted to terminals 1 & 2 the actuator must be reversed ● 50 50 50 50 50 50 50 50 Remarks Use MB valves blanking plug in third port with RM or ARM actuator linkage kit 2-port Valves Item ZVX Actuators 2-port, BSP parallel 1/2” ZVX 3201 3/4” ZVX 3202 1” ZVX 3203 AVUE (RA) ● 47 47 47 47 47 47 MEU Mk2 (3-Port) 627-2 CvS Product Selection - page no. 3-port, compression fitting 15mm ZV 1304 6 22mm ZV 1305 7 28mm ZV 1306 7.6 AVUE (DA) ● VEU Mk2 (2-Port) 623-2 Spec. no. VMF (Cast iron, globe construction, linear moving spindle, hot water or steam) VMF 3430 0.25 VMF 3431 1 VMF 3432 2.5 VMF 3433 4 VMF 3477 6.3 VMF 3527 10 VMF 3577 16 VMF 3627 25 VMF 3677 40 No equivalent available 6 7 Product Selection - page no. Valve/actuator compatibility Actuator No equivalent available 3-port, compression fitting 22mm ZVX 3401 7 Not compatible with CSMC controller ● Product Selection - page no. 2-port, compression fitting 15mm ZV 1204 6 22mm ZV 1205 7 28mm ZV 1206 7.6 ‘AVU & AVUE’ Valve/actuators – 230V/24V 0...10Vdc 230V 230V 230V 230V Size VM (Cast iron, globe construction, linear moving spindle, hot water or steam) VM 1405 0.2 ● VM 1406 0.5 ● VM 1407 1.2 ● VM 1408 2.5 VM 1452 5 VM 1502 8 VM 1552 12 VM 1602 20 AVU 2201 AVUE 4304 AVUE 4354 AVUX 4202 AVUM 4601 'R' Series Actuators RM 471-1-601 230V 471-2-601 230V Item VG (Screwed, bronze body, globe 1/2” VG 1401 3/4” VG 1451 1” VG 1501 VG 1551 11/4” 11/2” VG 1601 No equivalent available No equivalent available 1” ARM 2607 ARM 2657 ARX 2203 ARX 2253 ARE 2304 ARE 2354 RM 3601 Spec no. 7.6 2-port, BSP parallel with auxiliary switch 1/2” ZV 1251 6 3/4” ZV 1252 7 1” ZV 1253 7.6 – 8 Nm for MBF – for MB valves ‘AR & R’ Series Actuators – 230V/24V Item ZV 1203 3-port, BSP parallel 1/2” ZV 1301 3/4” ZV 1302 – 8 Nm for MBF – for MB valves ● Product Selection - page no. 47 47 47 47 47 Remarks ● ● 6 7 2-port, compression fitting with auxiliary switch 15mm ZV 1254 6 22mm ZV 1255 7 28mm ZV 1256 7.6 XRM 3201 RM 3601 Volt. Torque ARM 2656 ARM 2657 ARX 2252 ARX 2253 ARE 2352 Item 2-Port Valves Notes 2426 2427 2428 2429 2430 1476 1526 1576 1626 1676 RE 7352 RE 7351 Current Equipment VSF VSF VSF VSF VSF VSF VSF VSF VSF VSF 4 Nm 8 Nm CvS 1401 1402 1403 1404 1451 2501 2551 2601 24V ” Spec. no. VZ VZ VZ VZ VZ VZ VZ VZ RX 7252 RX 7251 Size MBF 4732 MBF 4782 MBF 4857 4 Nm 8 Nm Item Remarks MB 1552 MB 1602 MB 1652 230V ” ‘ZV & ZVX’ Valve/actuators – 230V/24V Notes OBSOLETE PRODUCTS ZVX 4201 ZVX 4202 ZVX 4203 ZVX 4301 ZVX 4302 ZVX 4303 ZVX 4401 ZY 1306 ZY 1206 RM 7652 RM 7651 Current Equipment ARM 2656 ARX 2252 ARE 2352 Volt. Torque Satchwell Valves 1402 1452 1502 1552 1602 1652 ‘RM, RX, RE’ Series Actuators – 230V/24V Item Satchwell Actuators & Valve/Actuators MB MB MB MB MB MB OBSOLETE PRODUCTS ● No replacement ● ● ● ● ● ● ● ● 46 46 46 46 46 59 OBSOLETE PRODUCTS Satchwell Valves 3-port Valves MA (Steam and high pressure hot water) 666-2-577 15 11/4” 666-2-627 15 11/2” 2” 666-2-677 39 ● No direct replacements ● ● ● ● ● ● ● ● ● ● ● ● ● ● 641-1-401 641-1-451 641-1-501 641-1-551 641-1-601 2.7 5.6 8.2 15 18 ● ● ● ● ● ● VM (Water) 1/2” 3/4” 1” 11/4” 1 1 /2” 641-1-401 641-1-451 641-1-501 641-1-551 641-1-601 2.7 5.6 8.2 15 18 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● VZ (Screwed, cast 1” 11/4” 11/2” 2” iron, globe construction, linear moving spindle (2 to 130°C max water) VZ 2502 8 ● VZ 2552 12 ● VZ 2602 20 ● VZ 2652 32 ● ● ● ● ● ● ● ● 633-1-203 633-1-253 633-1-303 633-1-353 633-1-403 633-1-453 633-1-503 633-1-533 633-1-603 633-1-653 633-1-727 633-1-777 0.18 0.33 0.68 1.2 2.2 5.6 10 15 22 39 56 82 ● ● ● ● ● ● MF (Water) 1/8” 3/16” 1/4” 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2” 21/2” 3” 633-1-201 633-1-251 633-1-301 633-1-351 633-1-401 633-1-451 633-1-501 633-1-551 633-1-601 633-1-651 633-1-726 633-1-776 0.18 0.33 0.68 1.2 2.2 5.6 10 15 22 39 56 82 ● ● ● ● ● MS (Steam) 3/4” 1” 11/2” 2” 631-1-453 631-1-503 631-1-603 631-1-677 12 18 33 68 ● MS (Water) 3/4” 1” 11/2” 2” 631-1-451 631-1-501 631-1-601 631-1-676 12 18 33 68 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● MM (Water) 1/2” 3/4” 654-1-401 654-1-451 2.7 5.6 MZ Screwed, cast 1” 11/4” 11/2” 2” 3729 3779 3854 3904 3958 ● MZF MZF MZF MZF MZF N/A N/A N/A N/A N/A N/A N/A N/A 3402 3452 3501 3551 3601 3651 MY MY MY MY MY MY MY MY MZ MZ MZ MZ MZ MZ MY (Water) 3/4” 1” 11/4” 11/2” 2” 21/2” 3” 4” ● ● Change actuator. ● ● ● ● Check application of valve and flow rate when replacing an MT with a MZ valve. ● ● ● ● ● ● ● ● ● ● ● ● ● Actuator to be changed. ● ● ● ● Check flow rate before selecting replacement valve. ● ● ● ● ● ● ● ● ● ● ● ● Actuator to be changed. ● iron, globe construction, linear moving spindle MZ 3502 8 MZ 3552 12 MZ 3602 20 MZ 3652 32 50 50 50 50 50 50 ● ● ● ● 50 50 50 51 51 51 51 51 51 51 51 51 51 51 ● ● ● ● VEU, MEU, FEU Valves ● Item Size Spec. no. CvS Current Equipment Notes Remarks ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Check Cv rating duty and absolute pressure Actuator must be replaced ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 VEU 2-port Unit Valves (2...120°C max water) 1/2” VEU 2414 0.63 ● 1/2” VEU 2415 1 ● 1/2” VEU 2416 1.6 ● 3/4” VEU 2626 4 ● MEU 3-port Unit 1/2” 1/2” 1/2” 3/4” 3/4” ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 60 Note:- All VSF valves are flanged ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● MH (Steam and high pressure hot water) 3/8” 656-1-377 1.2 ● ● ● ● ● 1/2” 656-1-427 2.2 ● ● ● ● ● 3/4” 656-1-478 5.6 ● 1” 656-1-528 10 656-1-578 15 11/4” 656-1-628 22 11/2” 2” 656-1-678 39 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Remarks ● ● ● ● ● ● ● ● ● ● ● N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Product Select. - page no. ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● MT MT MT MT MT MT MT MT MT MT Notes Check Cv rating duty and absolute pressure Actuator must be replaced Note:- All VSF valves are flanged 6414 6415 6416 6451 6452 6454 5626 5627 MF (Steam) 1/8” 3/16” 1/4” 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2” 21/2” 3” Product Selection - page no. Actuator to be replaced ● iron, globe construction, linear moving spindle (steam) 644-4-426 0.25 644-4-427 1 644-4-428 2.5 644-4-429 4 644-4-476 6.3 644-4-526 10 644-4-576 16 644-4-626 25 644-4-676 40 N/A N/A N/A N/A N/A N/A N/A Check Cv rating duty and absolute pressure ● VJF (Flanged, cast 15mm 15mm 15mm 15mm 20mm 25mm 32mm 40mm 50mm 656-1-376 656-1-426 656-1-477 656-1-527 656-1-577 656-1-627 656-1-677 Actuator to be replaced ● VM (Steam) 1/2” 3/4” 1” 11/4” 11/2” MH (Water) 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2” Check Cv rating duty and absolute pressure ● ● ● ● MT (Water) 3/4” 1” 11/4” 11/2” 2” 21/2” 3” 4” 5” 6” 1402 1452 1502 1552 1602 1652 ● ● Current Equipment FEU FEU FEU FEU FEU FEU FEU FEU 15 22 39 56 100 150 CvS 4422 4423 4425 4626 4627 666-2-576 666-2-626 666-2-676 666-2-726 666-2-776 666-2-861 Spec. no. MEU MEU MEU MEU MEU 56 100 150 Size 4414 4415 4416 4626 666-2-727 666-2-777 N/A Item VEU VEU VEU VEU 21/2” 3” 4” MA (Water) 11/4” 11/2” 2” 21/2” 3” 4” Remarks MB MB MB MB MB MB 2426 2427 2428 2429 2430 1476 1526 1576 1626 1676 VZ VZ VZ VZ VZ VZ VZ VZ VZ Notes VSF VSF VSF VSF VSF VSF VSF VSF VSF VSF Current Equipment 1727 1777 1852 1902 1954 CvS VZF VZF VZF VZF VZF Spec. no. 1401 1402 1403 1404 1451 2501 2551 2601 2651 Size OBSOLETE PRODUCTS MBF 4732 MBF 4782 MBF 4857 2-Port Valves Item Satchwell Valves Valves MEU MEU MEU MEU MEU (2...120°C max water) 2422 0.63 2423 1 2425 2 2626 4 2627 6 FEU 4-port Unit Valves (2...120°C 1/2” FEU 2414 1/2” FEU 2415 1/2” FEU 2416 15mm FEU 2451 15mm FEU 2462 15mm FEU 2454 3/4” FEU 2626 3/4” FEU 2627 1/2” FEU 5414 1/2” FEU 5415 1/2” FEU 5416 15mm FEU 5451 15mm FEU 5452 15mm FEU 5454 Product Selection - page no. See notes on valve/actuator compatibility above before specifying replacement valves. Applies to all valves. ● ● ● ● ● max water) 0.63 1 2 0.63 1 2 4 5.6 0.63 1 2 0.63 1 2 49 49 49 49 ● This is not a direct replacement as ports 1 and 2 have been reversed and pipe work modifications will have to be carried out. ● ● ● ● ● ● ● ● ● ● ● ● ● 49 49 49 49 49 49 49 49 49 49 49 49 49 Check Cv rating duty and absolute pressure Actuator must be replaced Note:- All VSF valves are flanged 61 SATCHWELL VALVE SIZING INFORMATION SATCHWELL VALVE SIZING INFORMATION CVs Values 40 25 16 10 6.3 4.0 2.0 2.5 0.5 0.2 0.25 2 3 1 0.8 0.6 0.5 0.4 0.3 0 3 0 10 0 9 0 8 0 7 0 1. .9 0 .8 0 .7 0 .6 0 Water Flow (l/s) 0. 60 50 40 30 5 0. 20 4 0 .3 0. 10 2 0.2 1 0. 26 0.6 0.5 0.4 0.2 20 0.1 0.08 0.06 0.05 0.04 0.3 26 00 20 10 9 00 8 0.03 7 0.1 0.08 0.06 0.05 0.04 0.03 (a) MZ, MZX, MZF, MJF, MEU, MB or MBF Valves 6 8 4 5 3 2 0.8 1 0.4 0.5 0.6 0.3 0.2 0.08 0.1 0.04 0.05 0.06 0.03 0.02 0.008 0.01 0.006 0.003 0.004 0.002 Valve Type P1 2 3 Source of heat Load Pump 3 2 1 3 Source of heat Load P2 Pump 1 (a) MB or MBF Valves only 2 Source of heat P1 Load P2 Pump (a) MB or MBF Valves only 62 For full details see Data Sheet ▼ VEU DS 4.101 MEU DS 4.101 FEU DS 4.101 BFB DS 4.103 VZ, VZX, VZF DS 4.110, 4.101 VSF DS 4.110 MB, MBF DS 4.501 MZ, MZX, MZF DS 4.610, 4.601 MJF DS 4.610 ra) ) Pa (k Pa ) e ur (k ss Pr es su re re tP le In le t In te ut e Required flow greater than 15 kg/h CVs = Q 13 (P1) 0.98 Note: The formulae take into account the 40% optimum pressure of drop automatically. Cvs = Flow in UK gal/min to produce 1lbf/in2 pressure drop when the valve is fully open Kvs = Cvs x 1.038. Kvs = Flow in m2/hr to produce 1 bar pressure drop when the valve is fully open. (a) MZ, MZX, MZF, MJF, MEU, MB or MBF Valves 1 e(b (ab leet tP Pr ess ssu nInl 30,000 20,000 8000 10,000 4000 5000 6000 3000 2000 800 1000 300 400 500 600 200 80 100 40 50 60 30 20 8 10 6 P1 + P2 so l 8 10 800 1000 2 Ab 4 5 6 3 1 ol u 3 300 400 500 600 3 4 5 6 8 10 2 0.4 0.5 0.6 0.8 1 0.3 Pump bs 2 200 Load Pump A 0.8 1 80 100 bAs 0.3 0.4 0.5 0.6 30 40 50 60 A 0.2 20 0.03 0.04 0.05 0.06 0.08 0.1 0.02 0.004 0.005 0.006 0.008 0.01 0.003 0.002 0.2 0.04 0.05 0.06 0.08 0.1 Pump Load 0 Source of heat 40 Load 0 Source of heat 50 FLOW COEFFICIENTS: Cvs Valve Source of heat 60 30 Required flow less than 15 kg/h CVs = Q 8 (P1) 1.56 P1 1 0 50 40 ALTERNATIVE STEAM VALVE SIZING METHOD As an alternative to the table the following formulae may be used:Q = Required flow in kg/h, P1 = Absolute inlet pressure in Bar. CONSTANT TEMPERATURE – VARIABLE VOLUME 3 0 60 3 Steam Flow (kg/h) Steam Flow (kg/s) 2 30 4 0. Note: Refer to appropriate valve Data Sheet for maximum allowable differential pressure. 1 l/s = 3.6m3/h 100 kPa = 1 Bar approximately equal to 1.02 kgf/cm2 approximately equal to 14.5 lbf/in CONSTANT VOLUME – VARIABLE TEMPERATURE 0 10 0 9 0 8 0 7 0. Pressure Drop (bar) Pressure Drop (kPa) 20 0.01 urer 3 0.006 0.005 0.004 0.003 0.02 00 10 00 9 00 8 00 7 0 4 0.01 0.008 r) 5 0.02 bos olul utet eI Water Flow (m3/hr) Water Flow (l/s) 6 5 4 1 .9 0 .8 0 7 0. .6 0 5 0. 0.006 0.005 0.004 0.003 0.25 0.2 20 4 2 0.01 0.008 1 0.8 5 10 8 2 0 6 0.02 0.63 0.5 0.4 2 30 7 ) a) PaP (k(k pp ro o DDr ree suur es s Pres 0.03 3 8 Pr 0.1 0.08 0.06 0.05 0.04 1.0 10 9 6 1.6 6 5 4 CVs Values Note: For maximum temperatures, internal pressures and differential pressures, refer to Data Sheet DS 4.110. ) ) arar (b(b pp ro o DDr ree suur es s Pres 10 8 4 3.2 2.5 2.0 00 10 00 9 00 8 00 7 0 60 0 50 0 40 Pr 3 6.3 * This is only 18% of absolute inlet pressure and the control quality will not be good until the valve has partially closed. As with all steam valves this compromise is necessary since the next smaller valve would not pass the required flow. Required flow: 900 kg/h Absolute inlet pressure: 2.5 bar Optimum pressure drop through valve = 40% of 2.5 = 1.0 bar Ideal Cvs = 27 Nearest available valve has Cvs 25. This is inadequate because the maximum flow = 800 kg/h ∴ Use next larger valve which has Cvs = 40 Pressure drop through valve = 0.45 bar* Max flow for same inlet pressure & Cvs = 1300 kg/h 20 16 12 10 8 30 20 0.2 40 32 25 60 50 40 6 5 4 0.6 0.5 0.4 0.3 100 80 60 50 40 30 80 63 100 80 10 8 1 0.8 120 200 20 Example: 200 200 600 500 400 300 100 80 60 50 40 30 2 280 1000 800 0.0003 0.0004 0.0005 0.0006 0.0008 0.001 200 0.03 280 STEAM VALVE SIZING CHART 1.0 WATER VALVE SIZING CHART ∆p (bar) = flow (m 3/h) Kvs 2 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 3/4” 3/4” 1” 11/4” 11/2” 2” 21/2” 3” 4” 5” 6” 15 mm 15 mm 15 mm 15 mm 15 mm 15 mm 20 mm 20 mm 25 mm 32 mm 40 mm 50 mm 65 mm 80 mm 100 mm 125 mm 150 mm – – – 0.4 – – – – – – – – 0.6 – 0.63 – – – – – – 1.0 0.2 1.0 – – – 0.63 0.63 0.63 1.6 0.5 1.6 – – – 1.0 1.0 1.0 2.0 1.0 2.5 – – 1.0 1.6 2.0 2.0 2.5 2.0 4.0 1.8 2.5 4.0 4.0 4.0 4.0 – 4.0 6.3 4.0 4.0 6.3 – 6.0 5.6 – – – – – – – – – – 8.0 10.0 8.0 8.0 10.0 – – – – 12 16 12 12 16 – – – – 20 25 20 20 25 – – – – 32 40 32 32 40 – – – – 63 – 63 63 – – – – – 80 – 80 80 – – – – – 125 – 120 125 – – – – – 200 – – 200 – – – – – 315 – – 315 – 63 SUPPORTING INFORMATION SENSOR RESISTANCE CHARTS °C –40 –39 –38 –37 –36 –35 –34 –33 –32 –31 –30 –29 –28 –27 –26 –25 –24 –23 –22 –21 –20 –19 –18 –17 –16 –15 –14 –13 –12 –11 –10 –9 –8 –7 –6 –5 –4 –3 –2 –1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 Ohms DR 2253 DW 1202 DWS 1202 DD 1401 DW 1305 DD 1403 DO 2202 DW 1204 DD 1304 2317.20 2462.00 2304.00 2459.00 2290.30 2455.80 2276.20 2452.30 2261.50 2448.70 2246.30 2444.90 2230.50 2440.80 2214.30 2436.50 2197.60 2432.00 2180.40 2427.20 2162.60 2422.10 2144.50 2416.80 2125.80 2411.20 2106.70 2405.30 2087.20 2399.10 2067.20 2392.50 2046.90 2385.70 2026.10 2378.50 2005.00 2371.00 1983.60 2363.10 1961.90 2354.80 1939.90 2346.20 1917.60 2337.10 1895.10 2327.70 1872.30 2317.90 1849.40 2307.70 1826.40 2297.00 1803.20 2285.90 1780.00 2274.40 1756.20 2262.40 1733.30 2250.00 1709.90 2237.20 1686.60 2223.90 1663.30 2210.10 1640.10 2195.90 1617.00 2181.20 1594.00 2166.00 1571.20 2150.40 1548.60 2134.40 1526.20 2117.80 1504.00 2100.90 1482.00 3033.10 2083.50 1460.30 3020.60 2065.60 1438.90 3007.70 2047.30 1417.80 2994.40 2028.60 1396.90 2980.50 2009.50 1376.40 2966.30 1990.00 1356.30 2951.60 1970.10 1336.50 2936.40 1949.90 1317.00 2920.80 1929.30 1297.90 2904.70 1908.30 1279.20 2888.20 1887.00 1260.80 2871.10 1865.50 1242.80 2853.70 1843.60 1225.30 2835.80 1821.50 1208.10 2817.40 1799.10 1191.20 2798.50 1776.50 1174.80 2779.30 1753.70 1158.80 2759.50 1730.70 1143.10 2739.40 1707.50 1127.90 2718.80 1684.20 1113.00 2697.80 1660.80 1098.50 2676.40 1637.30 1084.40 2654.60 1613.80 1070.60 2632.40 1590.20 1057.20 2609.80 1566.60 1044.20 2586.80 1542.90 1031.60 2563.50 1519.30 1019.20 2539.90 1495.80 1007.30 2515.90 1472.30 995.70 2491.70 1448.90 984.40 2467.10 1425.60 973.40 2442.30 1402.50 962.80 2417.20 1379.40 952.50 2391.90 1356.60 NOTES °C DWT DDT DDU DRT DST DOT DOS 9711.43 9692.31 9672.02 9650.72 9628.11 9604.43 9579.30 9552.97 9525.17 9495.97 9465.53 9433.11 9399.40 9364.27 9327.05 9288.26 9247.56 9205.09 9161.07 9115.04 9066.90 9016.81 8964.70 8910.56 8854.26 8795.91 8735.46 8672.68 8607.82 8540.79 8471.65 8400.00 8326.36 8250.52 8172.52 8092.69 8010.35 7925.74 7839.71 7751.29 7660.82 7568.68 7474.75 7378.77 7281.87 7182.31 7082.00 6979.77 6876.95 6772.11 6666.67 6560.03 6452.64 6343.69 6234.94 6125.53 6015.94 5905.00 5794.79 5684.07 5573.26 5462.80 5353.16 5242.63 5133.82 5024.89 4916.89 4809.78 4702.55 4596.64 4492.48 4389.27 4286.69 4185.03 4085.29 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 Ohms DR 2253 DW 1202 DWS 1202 DD 1401 DW 1305 DD 1403 DO 2202 DW 1204 DD 1304 942.40 2366.30 1333.90 932.70 2340.60 1311.50 923.30 2314.60 1289.30 914.10 2288.50 1267.20 905.30 2262.30 1245.50 896.70 2235.90 1224.00 2209.50 1202.70 2182.90 1181.80 2156.30 1161.10 2129.70 1140.80 2103.00 1120.70 2076.30 1101.00 2049.70 1081.60 2023.10 1062.50 1996.50 1043.80 1970.00 1025.40 1943.60 1007.30 1917.40 989.60 1891.20 972.20 1865.20 955.20 1839.40 938.50 1813.70 922.20 1788.20 906.20 1762.90 890.60 1737.80 875.30 1713.00 860.40 1688.40 845.80 1664.10 831.60 1640.00 817.60 1616.20 804.00 1592.70 790.80 1569.50 777.80 1546.50 765.20 1523.90 752.90 1501.60 740.90 1479.60 729.20 1458.00 717.80 1436.90 706.70 1415.60 695,90 1394.90 685.30 1374.60 675.10 1354.60 665.10 1334.90 655.40 1315.60 645.90 1296.70 636.70 1278.00 627.70 1259.70 619.00 1241.80 610.50 1224.20 602.30 1206.90 594.30 1190.00 586.50 1173.40 578.90 1157.10 571.50 1141.20 564.30 1125.60 557.30 1110.30 550.60 1095.40 544.00 1080.70 537.50 1066.40 531.30 1052.40 525.20 1038.60 519.40 1025.20 513.60 1012.10 508.10 99.30 502.70 986.70 497.40 974.40 492.30 962.50 487.30 950.70 482.50 939.30 477.80 928.10 473.20 917.20 468.80 906.50 464.40 896.10 460.20 885.90 456.20 875.90 452.20 64 °C DWT DDT DDU DRT DST DOT DOS 3986.77 3890.15 3795.37 3701.58 3609.00 3517.86 3428.40 3340.89 3255.55 3170.80 3089.15 3006.99 2927.86 2852.04 2776.13 2702.33 2629.17 2559.52 2490.80 2423.67 2358.25 2294.65 2232.41 2172.21 2112.94 2055.93 2000.00 1945.83 1892.99 1841.40 1791.84 1743.04 1695.73 1649.97 1605.81 1562.61 1520.39 1479.21 1439.82 1401.55 1363.68 1327.73 1292.23 1258.74 1225.76 1193.31 1162.17 1132.39 1103.20 1074.62 1047.45 1020.11 994.24 969.60 945.31 921.47 899.16 876.75 855.05 834.10 814.73 794.44 775.76 757.00 739.88 721.84 705.46 689.01 673.38 657.70 642.84 628.81 614.74 601.50 588.24 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 Ohms DWT DDT DDU DRT DST DOT DOS 574.93 563.37 550.88 539.26 527.61 516.83 506.03 496.10 486.16 476.19 466.20 457.11 448.90 439.77 431.54 423.29 415.03 407.67 400.31 392.93 385.54 379.07 371.65 365.16 358.65 353.08 346.56 340.96 335.36 329.76 324.14 319.46 313.83 309.14 304.44 299.74 295.03 290.32 286.55 281.83 278.05 DR 2253 DW 1202 DWS 1202 DD 1401 DW 1305 DD 1403 DO 2202 DW 1204 DD 1304 866.20 448.30 856.70 444.60 847.50 440.90 838.40 437.40 829.60 433.90 821.00 430.60 812.60 427.30 804.40 424.20 796.40 421.10 788.50 418.10 780.90 415.10 773.40 412.30 766.20 409.50 759.10 406.80 752.10 404.20 745.40 401.70 738.80 399.20 732.30 396.80 726.00 394.40 719.90 392.10 713.90 389.90 708.10 387.80 702.40 385.60 696.80 383.60 691.40 381.60 686.00 379.60 680.90 377.70 675.80 375.90 670.90 374.10 666.10 372.30 661.40 370.60 656.80 369.00 652.30 367.40 647.90 365.80 643.70 364.20 639.50 362.70 635.40 361.30 631.40 359.80 627.60 358.50 623.80 357.10 620.10 355.80 DC Range Sensor Resistance Chart °C –20 –18 –16 –14 –12 –10 –8 –6 –4 –2 0 2 4 6 8 10 12 14 16 18 20 22 24 26 A701, A702, A703, A704, A705 °C Ohms °C Ohms 331,020 293,370 260,370 231,410 205,960 183,560 163,820 146,400 131,000 117,380 105,310 94,596 85,080 76,614 69,078 62,355 56,352 50,985 46,185 41,883 38,022 34,557 31,440 28,634 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 26,107 23,827 21,768 19,907 18,223 16,697 15,314 14,059 12,919 11,882 10,937 10,077 9,292 8,577 7,922 7,324 6,777 6,275 5,815 5,394 5,006 4,650 4,323 4,021 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 Ohms 3,743 3,487 3,251 3,033 2,831 2,644 2,472 2,312 2,164 2,026 1,899 1,780 1,670 1,568 1,473 1,384 1,301 1,224 1,153 1,085 1,023 964 909 65 PRODUCT SELECTION Valves Valves Valves These valves are used for hot and/or chilled water control fan-coil units, induction units, solar energy on plants, small reheaters and dehumidifiers (in electric/electronic temperature control systems). VST, VMT, VTT Fan-coil Unit and Zone Valves (2, 3 & 4-port) INSTALLATION DETAILS Stroke - 5.5mm Pipe connections - male thread Characteristic - equal percentage A-AB port (VMT and VTT – B-AB linear) Rangeability - ≥ 50 Max fluid speed - 3m/sec International pressure rating - PN 16 This range of valves are used to control hot and cool water in zone systems, two/fourpipes terminal units and solar plants. VSZ, VMZ, VTZ INSTALLATION DETAILS Stroke - 3.5mm Pipe connections - male thread Characteristic - linear Max fluid speed - 3m/sec International pressure rating - PN 16 Fan-coil Unit and Zone Valves (2, 3 & 4-port) Order code** PN16 Valves (2 & 3-port) Size Two-port VST09 15mm VST10 15mm VST11 15mm VST12 15mm VST13 15mm VST1 15mm VST21 20mm VST2 20mm Three-port VMT09 15mm VMT10 15mm VMT11 15mm VMT12 15mm VMT13 15mm VMT1 15mm VMT2 20mm Three-port with built-in by-pass VTT09 15mm VTT10 15mm VTT11 15mm VTT12 15mm VTT13 15mm VTT1 15mm VTT21 20mm VTT2 20mm Data Sheet - VST-VMT-VTT Order code** Size Two-port VSZ09B 15mm VSZ10B 15mm VSZ11B 15mm VSZ12B 15mm VSZ13B 15mm VSZ1B 15mm VSZ21B 20mm VSZ2B 20mm Three-port VMZ09B 15mm VMZ10B 15mm VMZ11B 15mm VMZ12B 15mm VMZ13B 15mm VMZ1B 15mm VMZ2B 20mm Three-port (4-port) VTZ09B 15mm VTZ10B 15mm VTZ11B 15mm VTZ12B 15mm VTZ13B 15mm VTZ1B 15mm VTZ21B 20mm VTZ2B 20mm Data Sheet - VSZ-VMZ-VTZ Both 2-port VSB and 3-port VMB valve bodies can be used to control flow in air-conditioning, thermoventilation and heating systems, in environmental and industrial plants for machines employed for thermic treatment of products. 3-port valves must be used as mixing valves only; the angle port should never be used for control purposes. Valve stem down: straight-port open. VSB, VMB Valves Flow rate Kvs*, m3/h Max pressure rating (kPa) Limits 0.25 0.4 0.6 1 1.6 2.5 2.5 4 350 350 350 350 350 350 250 250 Water - 95°C max, 2°C min 0.25 (0.25) 0.4 (0.25) 0.6 (0.4) 1 (0.6) 1.6 (1) 2.5 (1.6) 4 (2.5) (4-port) 0.25 (0.25) 0.4 (0.25) 0.6 (0.4) 1 (0.6) 1.6 (1) 2.5 (1.6) 2.5 (1.6) 4 (2.5) 350 350 350 350 350 350 250 Flow rate Kvs*, m3/h 0.25 0.4 0.6 1 1.6 2.5 2.5 4 (0.25) (0.25) (0.4) (0.6) (1) (1.6) (2.5) 150 150 150 150 150 150 150 0.25 0.4 0.6 1 1.6 2.5 2.5 4 (0.25) (0.25) (0.4) (0.6) (1) (1.6) (1.6) (2.5) 150 150 150 150 150 150 150 150 Order codes 2-port 3-port VSB11 VMB11 VSB1 VMB1 VSB15 VMB15 VSB2 VMB2 VSB3 VMB3 VSB4 VMB4 VSB5 VMB5 VSB6 VMB6 VSB8 VMB8 VSB8A VMB8A Data Sheet - VSB-VMB INSTALLATION DETAILS Stroke - 16.5mm (max 18.5mm) Pipe connections - female thread Characteristic - VSB - equal percentage VMB - straight port - equal percentage, angle port - linear Rangeability - ≥ 50 International pressure rating - PN 16 Size 15mm 15mm 15mm 15mm 20mm 25mm 32mm 40mm 50mm 50mm Notes: 100 KPa = 1 bar = 10 m H2O ∆Pmax = maximum guaranteed differential pressure with closed valve and opened flow. VT valves are motorised with MVT actuators. * The values in brackets represent kvs on angle ways. ** Valves can be supplied NPT threaded. To order, add N to the ordering code, ie VST2N. Flow rate Kvs, m3/h 1 1.6 2.5 4 6.3 8 16 22 30 40 66 PN16 Valves (2 & 3-port) VSBT (2-port) and VMBT (3-port) valves can be used for fluid control in heating and air conditioning plants for both residential and industrial use, as well as with machines for thermic treatment. 3-port valves will only be used for mixing. Angle port (B-AB) is never to be used for control. Order codes 2-port 3-port VSBT3 VMBT3 VSBT4 VMBT4 VSBT5 VMBT5 VSBT6 VMBT6 INSTALLATION DETAILS Stroke - 5.5mm Pipe connections - female thread Characteristic - linear Rangeability - ≥ 50 Data Sheet - VSBT-VMBT These 2-port single seat valves are used to control fluids in air-conditioning, thermoventilation, heating plants and industrial processes. INSTALLATION DETAILS Stroke - see data sheet Characteristic - equal percentage Limits SS, VS Water - 95°C max, 5°C min Glycol added 50% max Single Seat Globe valves (2-port) ACCESSORY 245 – stem heater (24V) motorised with MVL actuator MAX DIFFERENTIAL PRESSURE (bar) Size Kvs mm VSG VSS SS SH 15R – – 1.6 – 15 – – 4 – 25R 4 4 – 2 (10) 20 – – 6.3 – 25I 6.3 6.3 – 2 (10) 25 10 10 10 2 (10) 32 – 16 16 – 40 25 25 22 2 (7.5) 50 32 40 32 2 (4.7) 65 63 63 63 2 (2.8) 80 100 – 110 1.7 100 130 – 140 0.8 125 200 – – 0.5 150 300 – – 0.3 15mm valve bodies can be supplied with CONEX connections (DN15). Add C to the order code, ie VST2C. Size 20mm 25mm 32mm 40mm Flow rate Kvs, m3/h 6.3 10 13 16 Max pressure rating (kpa) 1600 (16 bar) VSG 25...150mm 16 Cast iron Brass 150°C –10°C NP16 Water - 95°C max, 5°C min Glycol added 50% max MAX DIFFERENTIAL PRESSURE (bar) Order codes Actuators – max ∆P (bar) MVL VSBT3 170 VSBT4 100 VSBT5 70 VSBT6 50 VMBT3 170 VMBT4 100 VMBT5 70 VMBT6 50 Construction Limits Notes: 100 KPa = 1 bar ∆Pmax = max differential pressure value ensured by actuator for regular working conditions. SS-GA VSS SS-AA SS-AACP 15...100mm 25...65mm 15...100mm 15...100mm 16 25 40 40 Cast iron Cast iron Cast steel Cast steel Stainless steel Stainless steel Stainless steel Stainless steel 200°C 230°C 230°C 350°C** –10°C –10°C –10°C –30°C*** NP16 NP25 NP40 NP40 Body rating (bar) Body Plug Max. fluid temp. Min. fluid temp.* Flanged Data Sheet - SS-VS Notes: * For applications free from icing on stem and packing, see accessory option 245. ** With finned bonnet, high temp and forced lubrication. Low temp Teflon packing. *** For fluid temperature from –10 to –30°C add ‘B’ to the order code. VSG MVL – 2 (10) – 2 (10) 2 (10) – 2 (9.5) 2 (6) 2 (3.6) 2 (2.3) 1.4 0.8 0.4 MVLA/C – – 2 (10) – 2 (10) 2 (10) – 2 (3.5) 2 (2.4) 1.4 0.8 0.4 – – SH 6 (16) 6 (16) – 6 (16) – 6 (16) 6 (16) 6 (10) 6 (7) 2.5 1.5 1 – – SS-GA MVL MVLA/C 6 (16) 6 (16) 6 (16) 6 (16) – – 6 (16) 6 (14) – – 6 (16) 6 (9) 6 (16) 6 (9) 6 (13.5) 5.5 6 (9) 3.5 3.5 1.4 2.3 0.9 1.4 0.5 – – – – SH – – 8 (20) – 8 (18) 8 (16) 7.5 (12) 6.5 (8) 5.2 2.7 – – – – VSS MVL MVLA/C – – – – 8 (20) 7 (10) – – 8 (20) 7 (10) 8 (20) 7 (10) 8 (14) 6 8 (10) 4.5 6.5 2.7 3.7 1.4 – – – – – – – – SS-AA / MVL 10 (30) 10 (30) – 10 (30) – 10 (20) 10 (20) 10 (13) 8 3.5 2.4 1.4 – – SS-AACP MVLA/C 10 (30) 10 (20) – 10 (12) – 7.5 7.5 4.5 3 1 0.8 0.4 – – Notes: (100 KPa = 1 bar ∆Pmax = max differential pressure value ensured by the actuator for operation control. Values in brackets are the maximum differential pressure values when valve is fully closed. Max pressure rating (kpa) 1600 (16 bar) MAX DIFFERENTIAL PRESSURE (bar) Order codes Actuators – max ∆P (bar) 2-port 3-port MVB MVLA/C MVL SH +AG31 +AG31 +AG21 VSB1 VMB1 2 (10) 2 (10) 2 (10) 2 (10) VSB11 VMB11 2 (10) 2 (10) 2 (10) 2 (10) VSB15 VMB15 2 (10) 2 (10) 2 (10) 2 (10) VSB2 VMB2 2 (10) 2 (10) 2 (10) 2 (10) VSB3 VMB3 2 (10) 2 (10) 2 (10) 2 (10) VSB4 VMB4 2 (6.5) 2 (10) 2 (10) 2 (10) VSB5 VMB5 2 (4) 2 (6) 2 (10) 2 (10) VSB6 VMB6 2 (2.5) 2 (4) 2 (8) 2 (8) VSB8A VMB8A 2 (2) 2 (3) 2 (6) 2 (6) ACCESSORIES AG21 – linkage kit for SH actuators AG31 – linkage kit for MVL-MVLA/C actuators VSBT, VMBT 15mm valve bodies can be supplied with CONEX connections (DN15). Add C to the order code, ie VST2C. Max pressure rating (kPa) 0.25 0.4 0.6 1 1.6 2.5 4 (cont) Glycol added 50% max 350 350 350 350 350 350 250 250 150 150 150 150 150 150 150 150 PRODUCT SELECTION Water - 120°C max –10°C min Glycol added 50% max Saturated steam 120°C max 1.5 bar absolute max pressure Construction 2-port double seat valves are used to control fluids in air-conditioning, thermoventilation, heating plants and industrial processes. Limits Double Seat Globe Valves (2-port) DS-AACP 25...150mm 40 Cast steel Stainless steel 350°C** –30°C*** NP40 Body rating (bar) Body Plug Max. fluid temp. Min. fluid temp.* Flanged Data Sheet - DS Notes: * For applications free from icing on stem and packing, see accessory 245. ** With finned bonnet, high temp and forced lubrication. Low temp Teflon packing. *** For fluid temperature from –10 to –30°C add ‘B’ to the order code. INSTALLATION DETAILS Stroke - see data sheet Characteristic - equal percentage DS DS-AA 32...150mm 40 Cast steel Stainless steel 230°C –10°C NP40 ACCESSORY 245 – stem heater (24V) motorised with MVL and SH actuators MAX DIFFERENTIAL PRESSURE (bar) Size Actuators – max ∆P (bar) mm Kvs MVL MVLA/C 32R (rid.) 10 12 (30) 12 (30) 32 16 12 (30) 12 (30) 40 22 12 (30) 12 (30) 50 32 12 (30) 12 (30) 65 63 12 (30) 12 (14) 80 85 12 (30) 11 100 160 12 (20) 8.5 125 200 12 (20) 8 150 300 12 (14) 7 200 500 – – Notes: 100 KPa = 1 bar ∆Pmax = max differential pressure value ensured by the actuator for operation control. Values in brackets are the maximum differential pressure values when valve is fully closed. 67 Notes: 100 KPa = 1 bar ∆Pmax = max differential pressure value ensured by the actuator for operation control. Values in brackets are the maximum differential pressure values when valve is fully closed. PRODUCT SELECTION Valves Valves Valves (cont) VBS, VBG Balanced Valves PN16, PN25 (2-port) Valves Order codes VBS25R VBS25I VBS25 VBS32 VBS40 VBS50 VBS65 VBG80 VBG100 VBG125 VBG150 VBS and VBG balanced valve bodies can be used to control flow in air-conditioning, thermo-ventilation and heating systems, in environmental plants for both residential and industrial units. The special characteristic of these valves is they can work under high close off pressure and wherever low leakage is required. This makes them particularly suitable for applications with super-heated water (i.e. remote heating plants, boiler feeding, etc) and steam. INSTALLATION DETAILS Characteristic - equal percentage ACCESSORIES 244 – stem heater (24V) motorised with MVB actuator 246 – stem heater (24V) motorised with MVL and SH actuators Size Flow rate Kvs, m3/h 25mm 4 25mm 6.3 25mm 10 32mm 16 40mm 25 50mm 40 65mm 63 80mm 100 100mm 130 125mm 200 150mm 300 Stroke (mm) 16.5 16.5 16.5 25 25 25 25 45 45 45 45 Pressure rating PN25 PRODUCT SELECTION (cont) Limits Water - 230°C max, –10°C min Glycol added – 50% max Saturated steam 230°C max 7 bar absolute max pressure VM, 3V PN16 Water - 150°C max, –10°C min Glycol added – 50% max Saturated steam 150°C max 2 bar absolute max pressure Globe Valves (3-port) 3-port motorised valves are used to control fluids in air-conditioning thermo-ventilation, heating plants and industrial processes. Construction VMB16 25...150mm INSTALLATION DETAILS Stroke - see data sheet Characteristic - all valves linear, except VMB16 - straight port angle port = linear ACCESSORY 245 – stem heater (24V) motorised with SH and MVL actuators Body rating (bar) 16 Body Cast iron Plug Brass Max. fluid temp. 150°C Min. fluid temp.* –10°C Flanged NP16 Data Sheet - VM-3V 3V-GA 100...125mm VMS 3V-AA 3V-AACP 25...65mm 25...125mm 25...125mm 3VSA 80mm 16 25 40 40 Cast iron Cast iron Cast steel Cast steel Stainless steel Stainless steel Stainless steel Stainless steel 200°C 230°C 230°C 350°C** –10°C –10°C –10°C –30°C*** NP16 NP25 NP40 NP40 Notes: * For applications free from icing on stem and packing, see options 245. ** With finned bonnet, high temp and forced lubrication. Low temp Teflon packing. *** For fluid temperature from –10 to –30°C add ‘B’ to the order code. Data Sheet - VBS-VBG MAX DIFFERENTIAL PRESSURE (bar) Order codes Actuators – max ∆P (bar) MVL MVLA/C SH VBS25 7 (25) 12 (30) 7 (25) VBS32 7 (25) 12 (30) 7 (25) VBS40 7 (25) 12 (30) 7 (25) VBS50 7 (25) 12 (30) 7 (25) VBS65 7 (25) 12 (14) 7 (25) VBG80 2 (16) 2 (10) 2 (16) VBG100 2 (16) 2 (8) 2 (16) VBG125 2 (16) 2 (5.5) 2 (13.5) VBG150 2 (14.5) 2 (4.5) 2 (10.5) Notes: 100 KPa = 1 bar ∆Pmax = max differential pressure value ensured by the actuator for operation control. Values in brackets are the maximum differential pressure values when valve is fully closed. MAX DIFFERENTIAL PRESSURE (bar) Size Kvs VMB 16 mm VMB16 VMS 3V SH MVL MVLA/C 25R 4 4 4 2 (10) 2 (10) 2 (8) 25I 6.3 6.3 6.3 2 (10) 2 (10) 2 (8) 25 10 10 10 2 (10) 2 (10) 2 (8) 32 – 19 16 – – – 40R 19 – – 2 (8) 2 (10) 2 (4) 40 25 25 22 2 (8) 2 (10) 2 (4) 50 32 40 32 2 (5) 2 (6.7) 2 (2.6) 65 63 63 70 2 (3) 2 (4) 1.5 80 100 – 110 1.8 2 (2.4) 0.9 100 130 – 140 1 1.5 0.5 125 200 – 250 0.6 0.9 0.25 150 300 – – 0.4 0.5 0.15 VMS 3V-GA (DN 100 and 125) 3V-SATS (DN 80) 3V-SA (DN 80) SH MVL MVLA/C SH MVL MVLA/C MVL MVLA/C 8 (16) 8 (20) 7 (10) 6 (16) 6 (16) 6 (9) 5 5 8 (16) 8 (18) 7 (9) – – – – – 8 (16) 8 (18) 7 (9) 6 (16) 6 (16) 6 (9) 5 5 7.5 (10) 8 (13) 5.5 6 (10) 6 (14) 5.5 5 4 – – – – – – – – 7 7.5 (9) 4 6 (7) 6 (9) 3.5 5 2.5 5 6.3 2.5 5 6 2.5 5 1.5 2.7 3.5 1.4 2.5 3.5 1.4 3 1 – – – 1.5 2 0.8 2 0.5 – – – 1 1.3 0.5 – – – – – 0.5 0.8 0.2 – – – – – – – – – – Notes: (100 KPa = 1 bar ∆Pmax = max differential pressure value ensured by the actuator for operation control. Values in brackets are the maximum differential pressure values when valve is fully closed. Butterfly motorised valves are used in heating, refrigerating and hydraulic plants. Order codes INSTALLATION DETAILS Angular travel - 90° Maximum fluid temperature - 120°C VFG10-40 40mm 85 VFG10-50 50mm 130 VFG10-65 65mm 220 VFG10-80 80mm 340 VFG10-100 100mm 550 VFG10-125 125mm 900 VFG10-150 150mm 1400 VFG10-200 200mm 2500 Data Sheet - VF-ST400 Notes: Use ST or MDL actuators to drive valves. 2-port VSB.F and 3-port VMB.F valves can be used either for flow control in air-conditioning, thermo-ventilation and heating plants, both environmental and industrial, in machines for product thermal process. 3-port valves should be used only as mixing valves; angle port should never be used for control purposes. Order codes Size 2-port 3-port VSB11F VMB11F 15mm VSB1F VMB1F 15mm VSB15F VMB15F 15mm VSB2F VMB2F 15mm VSB3F VMB3F 20mm VSB4F VMB4F 25mm VSB5F VMB5F 32mm VSB6F VMB6F 40mm VSB8F 50mm VSB8AF VMB8F 50mm VSB9F VMB9F 65mm Data Sheet - VSB.F-VMB.F VFG10 PN10 Flanged Valves (2-port) VSB.F, VMB.F PN16 Flanged Valves (2 & 3-port) INSTALLATION DETAILS Stroke - 16.5mm (VSB9F & VMB9F 20mm) Characteristic - VSB - equal percentage VMB - straight port - equal percentage, angle port - linear Rangeability - ≥ 50 International pressure rating - PN 16 ACCESSORIES AG21 – linkage kit for SH actuators AG31 – linkage kit for MVL-MVLA/C actuators Size Flow rate Kvs, m3/h Max. differential pressure rating (kPa) with ST actuator 200 200 200 200 150 100 70 40 Flow rate Kvs, m3/h 1 1.6 2.5 4 6.3 8 16 22 30 40 63 Max pressure rating (kpa) 1600 (16 bar) MAX DIFFERENTIAL PRESSURE (bar) Order codes Actuators – max ∆P (bar) 2-port 3-port MVB MVLA/C MVL SH +AG31 +AG31 +AG21 VSB1F VMB1F 2 (10) 2 (10) 2 (10) 2 (10) VSB11F VMB11F 2 (10) 2 (10) 2 (10) 2 (10) VSB15F VMB15F 2 (10) 2 (10) 2 (10) 2 (10) VSB2F VMB2F 2 (10) 2 (10) 2 (10) 2 (10) VSB3F VMB3F 2 (10) 2 (10) 2 (10) 2 (10) VSB4F VMB4F 2 (6.5) 2 (10) 2 (10) 2 (10) VSB5F VMB5F 2 (4) 2 (6) 2 (10) 2 (10) VSB6F VMB6F 2 (2.5) 2 (4) 2 (8) 2 (8) VSB8AF VMB8F 2 (2) 2 (3) 2 (6) 2 (6) VSB9F VMB9F 1.5 1.5 2 (4) – 68 Limits Water - 120°C max –10°C min Glycol added 50% max Saturated steam 120°C max 1.5 bar (absolute) max pressure Notes: 100 KPa = 1 bar ∆Pmax = max differential pressure value ensured by the actuator for operation control. Values in brackets are the maximum differential pressure values when valve is fully closed. 69 3V-AA/3V-AACP MVL MVLA/C 10 (20) 7.5 – – 10 (20) 7.5 10 (12) 4.5 – – 8.5 3 5.5 2 3.5 1 2 0.7 1.3 0.4 0.8 0.2 – – PRODUCT SELECTION Actuators Actuators Actuators Actuators MVA actuators are used in V-ZB globe valve coupling for cool/warm water control in two and four pipe terminal units and zone systems. Model Control Control signal (power supply) MVA21 MVA23 On/off (with cable) On/off 110...230Vac ” MVA41 MVA43 On/off PWM (with cable) On/off PWM 24Vac ” PRODUCT SELECTION (cont) MVL actuators have linear characteristic (linear ratio between input signal and valve coupling joint movement). They are used for fluid control in air-conditioning-heating systems and in industrial processes. Data Sheet - MVA2./4 MVA INSTALLATION DETAILS Action - direct Stroke - 3.5mm (max) Stroke time - 3 min (opening), 8 min (closing) Thrust - 100 N (min) Protection class - IP 31 Electro-thermal Terminal Unit and Zone Valve Actuators MVT4 actuator is designed to provide, with VST and VSBT valve bodies, floating control of hot/cool water in two/four-pipe fan-coil units, zone and solar plants, reheat coils and dehumidification batteries. Model Control Control signal MVT44 3 position 24Vac MVL Pulsed and Proportional Linear Valve Actuators (700N & 1500N) Mod. Two different control types are available: - floating (3-point) - proportional (dc voltage or current) Raise Lower Actuators MVL26 22 MVL46 22 MVL46A 22 (16) MVL46C 22 (16) They are designed for direct coupling on all Controlli globe valves (add AG31 linkage for V.B valves) and they may also be used easily on valves of other manufacturers with 0...45 mm stroke for floating action models or 10...45 mm stroke for proportional action models. Proportional Actuators MVL56 22 MVL56A 22 (16) MVL56C 22 (16) Data Sheet - MVL Remark: INSTALLATION DETAILS Stroke - MVL2/4 0...45 mm, MVL5 10...45 mm Running speed - 1.33 s/mm Thrust - MVL 1500 N, MVL.A/C 700 N Protection class - IP 55 INSTALLATION DETAILS Action - direct/reversing Stroke - 6.5mm Running speed - 30 s/mm at 50 Hz, 25 s/mm at 60 Hz Thrust - 200 N Protection class - IP 40 Fan-coli Pulsed Valve Actuator ST actuators are used to control VFG butterfly valves in heating, refrigeration and hydraulic plants. The MVT5 actuator is designed to provide proportional control of both VST and VSBT valve bodies in fan-coil units, solar plants, reheaters and recoolers using hot and/or cold water. Control signal 24Vac Proportional – ranges 0...10, 6...10, 0...4, 2...10, 4...7, 6...9, 8...11Vac ST INSTALLATION DETAILS Action - direct/reversing Stroke - 6.5mm Running speed - 30 s/mm at 50 Hz, 25 s/mm at 60 Hz Thrust - 200 N Protection class - IP 40 Fan-coil Proportional Valve Actuator Pulsed and Proportional Linear Valve Actuators (450N) Supply MVT56 Data Sheet - MVT5 MVT56 MVB Model Rotary Valve Actuators (100N) These actuators are equipped with a reversing synchronous motor and an electronic board available in three different models respectively for: - floating control - proportional control (d.c. voltage or current) Model Timing (secs) Supply Control signal MVB26 MVB46 MVB56 MVB52 65 65 65 30 230Vac 24Vac 24Vac 24Vac Floating ” Proportional (V– or mA) ” Due to their versatility these actuators can be mounted both on new ‘Controlli’ globe valves up to DN 2” as well as on different manufacturers valves, with stroke from 10.8 to 20mm. Data Sheet - MVB Body valve Nominal diameter Model PN16 PN16 DN 1/2”...2” DN 1/2”...2” VSB (2-port) VMB (3-port) INSTALLATION DETAILS Angular travel - 90° Timing - 360 secs Torque - 10 Nm Radial force - 100 N (max) Protection class - IP 20 Shaft - Ø 20mm with 18x6 key MDL INSTALLATION DETAILS Action - direct/reversing Stroke - 21mm max (mechanical end stroke) Thrust - 450 N Protection class - IP 50 Output signal - for remote position indication 0...10V, 10...0V Damper Actuators SH INSTALLATION DETAILS Angular travel - 160° Timing - 80 secs Torque - 12 Nm Radial force - 1200 N (max) Protection class - IP 40 Shaft - Ø 16mm with pin hole Ø 4mm Manual override Model Supply Control signal SH222 SH242 SH522 24Vac 230Vac 24Vac 2 positions, 3 points from controller ” voltage or current variation from controller 60 60 60 (45) 60 (45) 230 V 24 V 24 V 24 V floating floating floating floating 33 33 (25) 33 (25) 60 60 (45) 60 (45) 24 V 24 V 24 V prop. (V or mA) prop. (V or mA) prop. (V or mA) MVL A/C models are fitted with spring return device. Values in brackets indicate the spring return time. A – spring return retracts (valve stem up) C – spring return extends (valve stem down) Supply Control signal ST404 ST405 24Vac 230Vac 2 positions, 3 points from controller ” Stroke time (s) 90°C 160°C Torque (Nm) Power supply Control signal MDL22 MDL24 MDL26 15 45 60 27 80 107 6 20 30 (8) (27) (40) 230Vac ” ” 3-point ” ” MDL42 MDL44 MDL46 15 45 60 27 80 107 6 20 30 (8) (27) (40) 24Vac ” ” 3-point ” ” MDL52 15 MDL54 45 MDL56 60 Data Sheet - MDL 27 80 107 6 20 30 (8) (27) (40) 24Vac ” ” proportional ” ” INSTALLATION DETAILS Action - direct/reversing Angular travel - 90° preset, 0...160° adjustable (55...160° adjustable - MDL5-) Thrust - 500 N max Protection class - IP 55 ACCESSORY AF22 – coupling for VFG butterfly valves. Data Sheet - SH--2 ACCESSORIES AG21 – linkage kit for fitting actuator to VMB and VSB valves D5 – one auxiliary microswitch (SPST) at end of stroke, rated 230V P-140-1 – auxiliary potentiometer 140Ω P-1000-1 – auxiliary potentiometer 1000Ω 245 – stem heater 24V (for valve applications with fluids below –10°C) Pulsed and Proportional Linear Valve Actuators (1200N) 70 33 33 33 (25) 33 (25) Model Model ACCESSORIES D36 – two auxiliary microswitches (SPDT) adjustable, rated 230V MVBPA2 – potentiometer for MVB46 (pcb with 1KΩ auxiliary pot.) 244 – stem heater 24V (for valve applications with fluids below –10°C) Series SH actuators are used in air conditioning, thermoventilation, heating systems and in industrial processes to drive dampers. Input Control Signal Data Sheet - VF-ST400 The MDL actuators are used in civil and industrial systems for driving dampers and other devices that require the control of an angular position within a maximum angle of 160° (e.g. for adjusting the flame n liquid or gas burners). Note: Timings refer to 16.5mm standard stroke. For different strokes see data sheet. Supply ACCESSORIES DMVL – two auxiliary microswitches (SPDT) adjustable, rated 230V, 10 (3) amp. MVLPA2 – potentiometer for MVL2 (pcb with 1KΩ auxiliary pot.) MVLPA4 – potentiometer for MVL4 ” MVLPA4M – potentiometer for MVL46A and MVL46C ” 245 – stem heater 24V (for valve applications with fluids below –10°C) AG31 – linkage kit for fitting actuator to VMB and VSG valves Data Sheet - MVT MVT44 Input Stroke/Time(s) 16.5 25 45 71 PRODUCT COMPATIBILITY Compatibilty and Selection Chart CONTROLLI VALVE SIZING INFORMATION Actuators FLUID VALVE SIZING CHART Flow liquid with specific gravity 1 kg/d3 m3/h Kvs = Q - 10 ∆pv Q = flow m3/h Flow liquid with specific gravity ∆pv = pressure drop (kPa) Flow pressure drop kPa (100 kPa = 1 bar = –10m H2O) different than 1 kg/dm3 m3/h Specific gravity Example for fluids with specific gravity 1 kg/dm3 (water) Example for fluids with specific gravity different than 1 kg/dm3 m3/h Flow : 30 m3/h fluid with specific gravity 0.9 kg/dm3 Pressure Drop : 20 kPa – Locate the crossing point (right side of diagram) between the line with starting point at specific gravity value 0.9 kg/dm3 and the sloping line at flow value 30 m3/h. – Locate the crossing point between the line with starting point at above crossing point and the line at pressure drop value 20 kPa. water Flow : 7.5 Pressure Drop : 55 kPa – Locate the crossing point between the line with starting point at flow value 7.5 m3/h and the line at pressure drop value 55 kPa. This point corresponds to flow coefficient Kvs 10, therefore control valve must have Kvs = 10. This point corresponds to flow coefficient Kvs 63, therefore control valve must have size Kvs = 63 (DN65). 72 73 CONTROLLI VALVE SIZING INFORMATION STEAM VALVE SIZING CHART CONDITIONS OF SALE 1. 2. a) b) c) 3. a) b) c) 4. 5. 6. a) b) c) d) e) f) g) 7. 8. a) b) c) d) e) f) g) h) i) j) k) Pr es su re dr op l) 9. a) C i rit ca l e pr ss u re dr op b) 10. 11. a) b) 12. a) Example for superheated steam: Flow : 140 kg/h superheated steam Absolute Inlet Pressure : 350 kPa Temperature : 209°C Pressure Drop : 100 kPa Calculate the superheating degree as follows: – Read the temperature value corresponding to 350 kPa (139°C) Superheating degree – 209 –139 = 70°C – Locate the crossing point (right side of diagram) between the line with starting point at superheating 70°C and the sloping line of 140 kg/h flow. – Locate the crossing point between the line with starting point at 350 kPa inlet pressure and the sloping line at 100 kPa pressure drop. – Locate the crossing point between lines with starting points. Example for saturated steam: Flow : 4700 kg/h saturated steam Absolute Inlet Pressure : 850 kPa Pressure Drop : 160 kPa – Locate the crossing point between the line with starting point at absolute inlet pressure 850 kPa and the sloping line of 160 kPa pressure drop. – Locate the crossing point between the line with starting point at above crossing point and the line of 4700 kg/h flow. This point corresponds to flow coefficient Kvs 63, DN 65, therefore control valve must have size 65mm. This point corresponds to flow coefficient Kvs 4. 74 b) c) d) 13. a) Definitions "Seller" means Satchwell Control Systems Limited. "Purchaser" means any party to whom Goods and/or Software are supplied by the Seller. "Goods" means the products which are the subject of sale between the Purchaser and the Seller. "Software" means the software or programs included in the Goods or ordered for use with the Goods. "Order" means any contract for the sale of Goods and/or Software by the Seller to the Purchaser. General Orders are accepted by the Seller subject to these terms and conditions and any special conditions, which together form the entire understanding between the parties, take precedence over any terms in the Purchaser's Order and supersede any previous agreements statements or representations for which the Seller can accept no liability, save in the case of fraudulent misrepresentation. Unless otherwise stated quotations lapse 30 (thirty) days from the date they were made. The Purchaser acknowledges that the Purchaser is not purchasing as a consumer. Price Unless otherwise specified, the price and relevant discount (if any) for the Goods and/or Software shall be that ruling at date of despatch. All prices are strictly nett and are exclusive of VAT and of all non-UK taxes, duties and levies. The Seller reserves the right to review all prices quoted for the Goods and/or Software in the event of devaluation of the pound sterling or fluctuation in rates of foreign exchange or the Euro. Packing Where special packing is ordered by the Purchaser, or is deemed necessary by the Seller, then the Seller will charge the Purchaser with the full cost of such special packing. Otherwise packing in accordance with the Seller's standard procedure is included in the product prices charged. Limits of Contract The Seller's acceptance of the Purchaser's Order includes only such Goods and/or Software as are specified in such acceptance. Specifications The descriptions and illustrations contained in the Seller's catalogues, brochures, price lists and other advertising media are intended merely to present a general idea of the Goods and/or Software described therein and do not form part of any contract for sale of the Goods and/or Software and no responsibility is accepted by the Seller for any errors or omissions therein or for any loss and/or damage resulting from the Purchaser's reliance on such descriptions and illustrations. Any performance figures given by the Seller are based upon the Seller's experience and are such as the Seller would expect to obtain on test in the Seller's works. The Seller shall be under no liability for damages for failure to attain such figures unless the Seller has guaranteed such performance figures in writing for the specific installation. If the Goods and/or Software performance criteria obtained on any test is outside the guaranteed performance figures referred to in 6.b) above, then the Seller will be given reasonable time and opportunity to rectify the said performance requirements. Should the Seller fail to rectify the said performance requirements, then the Purchaser will be entitled to reject the Goods and/or Software within twelve months of the date of delivery unless agreed otherwise in writing by the Seller. The Purchaser assumes responsibility that the Goods and/or Software stipulated by the Purchaser are sufficient and suitable for the Purchaser's intended purpose. Unless expressly stated otherwise by the Seller, no responsibility is accepted by the Seller for any errors, omissions or other defects in any drawings, designs or specifications not prepared by the Seller. The Purchaser will indemnify the Seller against any and all liabilities and/or expenses so incurred by the Seller as a consequence of any such error, omission or other defect. The Purchaser shall not copy, without the prior written consent of the Seller, any documentation supplied by the Seller. All documentation supplied by the Seller shall remain at all times the property of the Seller. Inspection and Tests The Seller's products are carefully inspected and submitted to the Seller's standard tests at the Seller's works before despatch. If tests in the presence of the Purchaser or the Purchaser's representative are required, these will be charged for. In the event of any delay on the Purchaser's part in attending such tests or in carrying out any inspection required by the Purchaser after seven days notice that the Seller is ready, the tests will proceed in the Purchaser's absence and shall be deemed to have been made in the Purchaser's presence. Despatch and Delivery Any times quoted for despatch will date from the Seller's acceptance of the Purchaser's written Order and where necessary the opening of an Irrevocable Letter of Credit. Any dates given for despatch by the Seller are estimates only and will not involve the Seller in any liability for failure to despatch on any particular date or dates. In the event that the Seller shall fail to despatch the Goods and/or Software within 30 days of the estimated date, then the Purchaser shall be entitled to serve notice upon the Seller requiring the Seller to effect despatch within 30 days of receipt of such notice, failing which, the Purchaser may terminate the Order without further charge on either side. If no delivery date is stated by the Purchaser then the Seller will deliver the Goods and/or Software within such reasonable period as the Seller shall determine. The Purchaser's Order may be dispatched in installments provided always that any such despatch will be deemed to be a separate contract governed by these Conditions of Sale. Unless expressly stated otherwise by the Seller, the Seller's price includes the cost of delivery of the Goods and/or Software to an address or a carrier within the UK. The Purchaser shall state the point of delivery on the Order. The Seller retains the right to select the method of carriage. Where the Purchaser orders any special carriage requirements, or these are deemed necessary by the Seller, then the Seller will charge the Purchaser for the full cost of such special carriage requirements. Off-loading at the point of delivery shall in all circumstances be at the Purchaser's cost and risk unless otherwise agreed in writing by the Seller. Any dimensions, weight or quantities of packing stated by the Seller are estimates only. In the event that the Purchaser or carrier fails to accept delivery of the Goods and/or Software, the Purchaser shall on demand pay the Seller for and/or indemnify the Seller against any liabilities for all services provided or used by the Seller in consequence, including, but not limited to, insurance, storage or handling and the Seller shall have a lien over any such Goods and/or Software. If the quantity of Goods and/or Software received by the Purchaser does not equate to the quantity of Goods and/or Software ordered, (or in the case of part-shipments the quantities advised by the Seller) then the Purchaser is required to notify the Seller in writing of the discrepancy within 7 calendar days of receipt of the Goods and/or Software. The Purchaser will not be entitled to reject any Goods and/or Software by reason of short delivery. Should the Purchaser return Goods and/or Software which the Seller has dispatched in accordance with the terms and conditions of the Order without reason, then the Purchaser will pay a re-stocking charge to a maximum of 25% of the price of the Goods and/or Software so returned. Time for delivery shall not be of the essence. Loss or Damage in Transit The Seller will repair, or at the Seller's option replace, free of charge, Goods and/or Software lost or damaged up to the point of delivery provided that the Seller and the carriers receive written notification of such damage within three days of delivery, or if lost, within ten days from the date the Seller has acknowledged the Goods and/or Software will be dispatched. The Seller's obligations hereunder are in lieu of all other liabilities that might otherwise arise in respect of such loss or damage and it's consequences. The Purchaser will afford the Seller reasonable opportunity to inspect the Goods and/or Software alleged to be damaged, as and where delivered, should the Seller wish to do so. Storage If the Seller does not receive forwarding instructions sufficient to enable the Seller to despatch the Goods and/or Software within 14 days of the acknowledged despatch date, the Seller shall be entitled to arrange alternative storage facilities or reallocate the Goods and/or Software at the Seller's sole discretion and any costs incurred by the Seller for storage, insurance or demurrage shall be charged to the Purchaser. Risk Risk in the Goods and/or Software will pass to the Purchaser at the point of delivery. It is a condition of the Order that both the Purchaser and the Seller shall individually effect and maintain adequate insurance cover in respect of the risks each party has accepted under these Conditions of Sale. Title Title in the Goods (excluding Software) will not pass to the Purchaser until payment in full for the Goods has been received by the Seller. Until such time, the Purchaser's possession of the Goods shall be as bailee for the Seller and the Purchaser will store the Goods in a manner which enables the Goods to be clearly identified as the property of the Seller. Notwithstanding 12(a) above:- (i) if the Goods and/or Software are purchased for re-sale by the Purchaser in the normal course of the Purchaser's business, then the Purchaser may as agent for the Seller sell and deliver the Goods and/or Software to the third party strictly on condition that all proceeds of such sales shall be held in trust and in a separate account for the Seller until the time that full payment to the Seller has been effected. Until such time, the Seller reserves the option, on written notice to the Purchaser, to have assigned to the Seller, all rights and claims which the Purchaser may have against third parties arising from such sales. (ii) Should the Goods and/or Software be incorporated or combined with other items of equipment or materials by the Purchaser or others acting on his behalf, then the Seller shall retain the legal and beneficial title to the Goods and/or Software and the Purchaser agrees to store the Goods and/or Software so incorporated or combined in accordance with the provisions of 12(a) above or the Purchaser may re-sell such Goods and/or Software to a third party subject to the terms of 12(b)i) above. Should payment to the Seller for any Goods and/or Software become overdue, then the Seller reserves the right to repossess any such Goods and/or Software and to re-sell the same. For this purpose the Purchaser will grant the Seller's representative vehicular access, during normal business hours, to all or any of the premises used by the Purchaser for storing the Goods and/or Software. Title in the Software will remain at all times vested in the Seller. Terms of Payment Unless otherwise agreed in writing by the Seller payment in full for Goods and/or Software shall be received by the Seller at Farnham Road, Slough, Berkshire SL1 4UH, England prior to date of despatch. Payment will be made in pounds sterling unless REGISTERED IN ENGLAND: No. 00081433 agreed otherwise by the Seller and if made by cheque or other negotiable instrument, will not be effective until it is honoured and the Seller's bank account is credited with the amount due. b) Payment by the due date is the essence of every Order. Failure by the Purchaser to ensure payment is received by the Seller on or before the due date shall entitle the Seller without prejudice to any other rights or remedies which the Seller may possess:- (i) to withhold further despatches under this and any other contract existing between the Seller and the Purchaser for the purchase of Goods and/or Software. (ii) to offset overdue monies against any sums which may be owed by the Seller to the Purchaser under any other contract. (iii) to charge interest at 8 percent above the Bank of England's base rate in accordance with The Late Payment of Commercial Debts (interest) Act 1998. c) Any payment made by the Purchaser to the Seller which has not been apportioned by the Purchaser to specific debts will be apportioned as the Seller believes to be correct. d) Credit facilities extended by the Seller to the Purchaser are at the sole discretion of the Seller and may be revised or withdrawn at any time without prior notification being provided to the Purchaser. 14. Defects after Delivery a) Unless expressly stated otherwise by the Seller, the Seller will make good, by repair or at the Seller's option by the supply of a replacement, defects which, under proper storage and use, appear in the Goods and/or Software within a period of twelve calendar months after the Goods and/or Software have been dispatched and which arise solely from faulty design (other than a design made, furnished or specified by the Purchaser for which the Seller has disclaimed responsibility in writing), materials or workmanship: provided always that defective parts have been returned to the Seller if the Seller shall have so required. The repaired or new parts will be delivered by the Seller free of charge as provided in condition 8 above. b) In the case of Goods and/or Software not of the Seller's manufacture the Purchaser is entitled only to such benefits as the Seller may receive under guarantees given to the Seller in respect thereof, but not so as to impose on the Seller in respect of such parts or components a liability greater than that imposed upon the Seller by the preceding paragraph of this condition. c) The Seller's liability under this condition 14. shall be in lieu of any warranty or condition implied by law as to the quality or fitness for any particular purpose of the Goods and/or Software, and save as provided in this condition 14., the Seller shall not be under any liability, whether in contract, tort or otherwise, in respect of defects in Goods and/or Software delivered or for any injury (other than personal injury caused by the Seller's negligence as defined in Section 1 of the Unfair Contract Terms Act, 1977), damage or loss resulting from such defects or from any work done in connection therewith. 15. Patents The Seller will indemnify the Purchaser against any claim for infringement of Letters Patent, Registered Design, Trade Mark or Copyright (published at the date of the Order) by the use or sale of any article or material supplied by the Seller to the Purchaser and against all costs and damages which the Purchaser may incur in any action for such infringement or for which the Purchaser may become liable in any such action. Provided always that this indemnity shall not apply to any infringement which is due to the Seller having followed a design or instruction furnished or given by the Purchaser or to the use of such article or material in a manner or for a purpose or in a country not specified by or disclosed to the Seller, or to any infringement which is due to the use of such article or material in association or combination with any other article or material not supplied by the Seller. Provided also that this indemnity is conditional on the Purchaser giving to the Seller the earliest possible notice in writing of any claim being made or action threatened or brought against the Purchaser, the Purchaser not making any admission of liability and on the Purchaser permitting the Seller at the Seller's own expense to conduct any litigation that may ensue and all negotiations for a settlement of the claim. The Purchaser on his part warrants that any design or instruction furnished or given by the Purchaser shall not be such as will cause the Seller to infringe any Letters Patent, Registered Design, Trade Mark or Copyright in the execution of the Purchaser's order. 16. Liability a) Notwithstanding the provisions of condition 14. above, the Seller will not, in any circumstances, be liable to the Purchaser or a third party for any loss of use, loss of production, loss of reputation, loss of goodwill, loss of profit, loss of business, loss of contracts, loss of revenues, loss of anticipated savings, increase in operating costs, financial or economic loss, indirect loss, consequential loss or any other damage suffered. b) Subject to condition 16 (c) below, the exclusions and limitations of liability set out in condition 16 (a) above will apply to all claims of any kind whether as a result of breach of contract, statutory duty or warranty, negligence or otherwise on the part of the Seller, its employees, agents, subcontractors or suppliers who will have no greater liability in relation to these Conditions of Sale than the Seller. c) The Seller will compensate the Purchaser for any legal liability for personal injury to or death of any person or damage to any property to the extent that such personal injury or death or damage is caused by the negligence of the Seller or of its employees or agents. d) In the case of damage to property, other than the Goods and/or Software supplied under these Conditions of Sale, such compensation will unless otherwise specified in these Conditions of Sale be limited to the value of Goods and/or Software ordered in respect of any one occurrence or series of occurrences originating from one incident. e) The total aggregate liability of the Seller for all other claims of any kind for any loss or damage resulting from its performances or lack of performance under these Conditions of Sale in any twelve calendar month period will not in any event exceed an amount equal to the value of Orders accepted by the Seller from the Purchaser in that twelve calendar month period. f) The Purchaser will indemnify the Seller against any and all claims in respect of or consequent to pollution or to the release of substances capable of causing harm to living organisms or interference with ecological systems arising from the Goods and/or Software except in respect of personal injury or death, whether or not resulting from the negligence of any person. g) If the Purchaser is not the sole end user and ultimate owner of the Goods and/or Software, then the Purchaser will ensure by its contract with the end user or ultimate owner or its buyer that the Seller is given the benefit of the exclusions and limitations of liability set out in these Conditions of Sale by all such users, owners and buyers and will indemnify the Seller against claims of any kind by them to the extent that the Seller would not be liable to the Purchaser under these Conditions of Sale if the claim had been made by the Purchaser. 17. Force Majeure Should the Seller be delayed, hindered or otherwise prevented from complying with the terms of the Order by reason of events or circumstances beyond the reasonable control of the Seller including but not limited to Acts of God, wars, riots, strikes, lockouts, trade disputes, fuel shortages or labour disturbances, breakdown of plant or machinery, accident, storm, fire, flood, difficulties in obtaining materials, transport or labour or any other circumstances affecting the supply of the Goods and/or Software, then the Seller shall not be liable to the Purchaser for any loss or damage which may be suffered by the Purchaser whether as a direct or indirect result of any such occurrences. 18. Software All rights in the Software will remain at all times vested in the Seller. The Seller shall licence the Purchaser to use any Software that is specified in an Order on the terms set out in the Seller's applicable Software/Computer Program Licence Agreement provided with the Software. In the event that the Seller shall not have received payment in full for the Goods and/or Software to which the licence relates within 30 days of the due payment date then the Purchaser's right to use the Software pursuant to such Software/Computer Program Licence Agreement shall cease without further notice. 19. Cancellation Should the Order be cancelled in whole or in part by the Purchaser prior to despatch of the Goods and/or Software then the Purchaser agrees to reimburse the Seller for all costs arising from design, manufacture, packing and storage of the Goods and/or Software and in addition shall pay compensation at a level of 20% of the Order value in respect of loss of profit, restocking and administrative charges. The rights of the Purchaser to cancel the Order under this condition are without prejudice to the rights of the Seller if such cancellation is executed vexatiously or otherwise amounts to a wrongful repudiation of the Order. 20. Licences Should any licence or consent of any government or other authority be required for procurement, carriage or use of the Goods and/or Software by the Purchaser, then the Purchaser shall acquire the appropriate licence or consent at the Purchaser's own expense and if requested by the Seller, shall produce evidence of the same on demand. The failure of the Purchaser to obtain any necessary licence or consent will not entitle the Purchase to withhold or delay payment of the purchase price beyond the due date. Should the Seller incur any additional direct or indirect expenses or charges resulting from the Purchaser's failure to obtain any necessary licence or consent, then these will be for the Purchaser's account. 21. Statutory and Other Regulations If the cost to the Seller of performing the Seller's obligations under the Order shall be increased by reasons of the making or amendment of any law or of any other regulation or bye-law having the force of law that shall affect the performance of the Seller's obligation under the Order, the amount of such increase shall be added to the Order price. 22. Insolvency The Seller shall, without prejudice to any of its other rights, be entitled at any time to stop any Goods and/or Software in transit and/or suspend further deliveries or services and/or by notice in writing to the Purchaser determine the Order should the Purchaser become bankrupt, make a composition or arrangement with its creditors, have a winding up order made or (except for the purposes of amalgamation or reconstruction) a resolution for voluntary winding up passed or have a provisional liquidator, receiver or manager of his business or undertaking duly appointed or having possession taken, by or on behalf of the holders of any debentures secured by a floating charge. 23. Waiver The failure by the Seller to exercise or enforce any rights under these Conditions of Sale shall not be deemed to be a waiver of any such rights, neither will it operate so as to prevent the exercise or enforcement of the Seller's right at any time or times thereafter. 24. Notices Any notices given hereunder by the Seller or the Purchaser shall be deemed to have been duly given if sent to the last known address of either party, by first class post three days after despatch or, on the date of despatch if given by telefax, telex, telegraph or other electronic system of communication. 25. Contracts (Rights of Third Parties) Act 1999 The parties agree that no term or condition of these Conditions of Sale will be enforceable by virtue of the Contracts (Rights of Third Parties) Act 1999 by any third party. 26. Legal Construction Unless otherwise agreed in writing the Order shall in all respects be construed and operate as an English contract and in conformity with English Law and is subject to the exclusive jurisdiction of the English Courts. REGISTERED OFFICE: INVENSYS HOUSE, CARLISLE PLACE, LONDON SW1P 1BX, UNITED KINGDOM 75 SATCHWELL CONTROL SYSTEMS LIMITED (T/A CLIMATE CONTROLS EUROPE)
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement