INDEX
Welcome to this new edition of our Product Selection Guide,
encompassing Satchwell, Drayton and Controlli products in a single
publication, complete with recommended retail prices. The Guide is
designed to make it as easy as possible for you to identify the items you
need, for both new projects and replacement of installed items.
Range
Description
MICRONET
SYSTEM
Software
VisiView
MicroNet View
VisiSat™ Configuration Tool
WorkPlace Tech Tool
Remote Alarm Manager
CSM Tool
Controllers (LONMARK®)
MN 11 & 13 Fan Coil Unit Controller
MN 50 Programmable Controller
MN 100, 150 & 200 Programmable Controllers
VAV Controllers with/without Integral Actuator
Controllers (Bus-du-jour®)
MN 300, 440 Controllers with NCP
MN 500, 620 Controllers with NCP
Digital Modules
Digital Output Module
Fan Coil Unit Solutions
Bonsai® Pro & Lite Fan Coil Unit Controller
UniFact® Pro Terminal Unit Controller
Interfaces
Manager Interface with Bus-du-jour
ARCNET® Router
Touch Screen Display
LCD Display
Digital Room Temperature Sensors
Sensors
Room Temperature Sensors
Valves
Bonsai Fan Coil Unit Valves
USING THE PRODUCT SELECTION GUIDE
Index Pages
The individual products are listed in the order that they appear in the main section of the
Guide. If they also appear in the Product Compatibility and Obsolete Product sections, the
relevant page numbers are shown in the adjacent columns (applies only to Satchwell brand
products).
Brands
Drayton brand products can be found on page 34
Controlli brand products and supporting information can be found on pages 66 - 74
The remainder of the Guide is devoted to Satchwell brand products.
Data Sheets
The Guide provides a convenient summary of the functionality and technical specification
of each product. For full technical information, the reference number of the relevant data
sheet is shown.
DRAYTON
RANGE
FURTHER INFORMATION
We provide a series of additional resources in the form of printed documentation,
electronic files, an Internet site, and the services of our Customer Care Centre.
Details are shown below.
Product Range Catalogue
The Product Range Catalogue is a compendium of all our data sheets. It is available in both
CD-ROM and ring binder formats. Contact Customer Care to obtain a copy.
Web Site
Check our total portfolio by visiting our Internet site at www.satchwell.com, which also
gives direct access to the latest versions of all our data sheets in pdf format.
Customer Care Centre
Our Customer Care Centre is available to answer all your questions, and can put you in
direct contact with the sales office responsible for your area.
Customer Care details are as follows:
Tel: +44 (0) 1753-611000
Fax: +44 (0) 1753-611001
Email: [email protected]
Controllers
Self Configuring Optimiser/Compensator
Sensors
Room, outside, immersion, duct and surface
Relay and Switching Units
Relay Units
Remote Switch Unit (RSU)
SATCHWELL
Optimiser
CONTROLLERS 7-day Optimiser
Compensator
Compensator Controller
Main Plant Controllers
AHU Room Reset Controller
PID Pulse Controller
PID 0...10V Controller
Keyboard
C/O Step Control Function Module
Multiple Application PID Controller
Universal Air Handling Unit Controller
Multi-Loop District Heating Controller
Terminal Unit
Fan Coil Unit Controller
Networking
Modem Interface Unit
Intelligent/Programmable
Universal Multi-loop Intelligent Advanced Controllers
Touchscreen for IAC Controllers
SENSORS
Price
List
Product
Selection
Product
Compatibility
Obsolete
Products
VV-LITE, VV-LITE-TO-STD,
VV-STANDARD
MN-VW, MN-VWP, MN-VWIO
MN-VSCORE, MN-VSLON
WP-TECH
MN-RAM, MN-RAM-OUT
CSM-CORE
6
6
6
6
6
6
25
25
25
26
26
26
-
-
MN
MN
MN
MN
6
6
6
6
26
27
27
27, 28
53
53
53
53
-
MN 300, MN 440
MN 500, MN 620
6
6
28
29
53
53
-
579-1-360
9
30
-
-
BRC
URC
7
7
31
31
53
53
-
MN MI
MNA R10
MN TS, MNL TS
MN LCD, MNL LCD
MN Sx
7
7
7
7
7
32
32
32
32
33
-
-
DU, DUS, DUSF
7
33
-
-
BFB
8
31
-
-
DC1100, DC1100C
8
34
-
-
A type
8
34
-
-
RB
04 03 109
8
8
34
34
-
-
SVT
9
35
53
55
CSC
9
35
53
55
CXR
CXT
CZT
9
9
9
35
36
36
53
53
53
56
56
56
FLS
KMC
MMC
MMC
9
9
9
9
36
36
37
37
53
53
53
55
55, 56
55, 56
55, 56
CZU
9
37
53
55
MIU
9
38
-
-
IAC 420, IAC 600
IAC-TS
9
9
38, 39
39
-
-
DR/DRT
DRT
DU, DUS, DUSF
DRTE
DRH, DRTH
DRCO
10
10
10
10
10
10
39
40
40
40
40
41
53
53
53
-
56
56
56
-
DDT
DDU
DDH, DDTH
10
10
10
41
41
41
53
53
53
56
56
56
Code
Room Temperature & Humidity Sensors
Air Temperature Sensors
Temperature Sensors with Fan Speed Switches
UniFact Pro and MicroNet Sensors
Active Temp. Sensors with/without Fan Speed Switches
Humidity/Temperature Sensors
Carbon Dioxide Sensors
Duct Temperature, Humidity, Pressure & Air Velocity Sensors
Air Temperature Sensor
Fan Coil Unit Return Air Temperature Sensors
Humidity/Temperature Sensors
3
11, MN 13
50
100, MN 150, MN 200
VAV
INDEX
INDEX
Range
Description
Code
Price
List
SENSORS
(cont)
Duct Temp., Humidity, Pressure & Air Velocity Sensors (cont)
Differential Air Pressure Sensor
Air Velocity Sensor
Carbon Dioxide Sensors
DDP
DDV
DDCO
10
10
10
41
42
42
-
57
-
Pipe Temperature Sensors
Water Temperature Sensor (Surface Pipe)
Water Temperature Sensor (Immersion)
Fast Response Water Sensor (Immersion)
DST
DWT
DWT
10
10
10
42
42
42
53
53
53
56
56
56
Outside Sensors
Outside Temperature Sensor
Outside Solar Sensor
Wind Influence Sensor
DOT
DOS
DOW
11
11
11
43
43
43
53
53
53
56
56
-
Remote Adjustment
Remote Setting Unit
RPW
11
43
53
-
Cast Iron Bodies, Screwed, Short Stroke
VSBT
17
67
72
-
Cast Steel Bodies, Flanged
”
”
”
”
(Low Temperature)
”
”
(High Temperature)
Balanced Valves, Flanged
SS-AA, DS-AA
SS-AACP
DS-AACP
SS-AACP
VBS, VBG
17
18
18
18
18
67
67
67
67
68
72
72
72
72
72
-
2-port Butterfly Valves
Cast Iron Bodies, Flanged
VFG
18
68
72
-
3-port Valves (plug & seat)
Cast Iron Bodies, Screwed
”
Flanged
VMB, VMBT
VMB.F, VMS, 3V-SA, 3V-GA
19
19
67, 68
67, 68
72
72
-
Cast Iron Bodies, Screwed, Short Stroke
VMBT
19
67
72
-
Cast Steel Bodies, Flanged
”
”
(Low Temperature)
”
”
(High Temperature)
3V-AA
3V-AACP
3V-AACP
19
20
20
69
69
69
72
72
72
-
Linear Drives
Pulsed and On/off
(100N)
MVA
21
70
72
-
Pulsed and Proportional Actuators
”
”
”
”
”
”
”
”
(200N)
(200N)
(450N)
(1200N)
(700N & 1500N)
MVT44
MVT56
MVB
SH
MVL
21
21
21
21
21
70
70
70
70
71
72
72
72
72
72
-
Rotary Drives
”
(10Nm)
(6, 20 & 30Nm)
ST
MDL
21
21
71
71
72
72
-
PRICE SUMMARY Alphanumeric List, Controlli
–
23
-
-
-
VALVE SIZING INFORMATION
–
-
73, 74
72
-
SWITCHES &
Duct Thermostats, Pressure & Air Velocity Switches
THERMOSTATS Air Temperature Thermostats
Universal Differential and Universal Pressure Switches
Air Flow Switch
Air Differential Pressure Switch
Product
Selection
Product
Compatibility
Obsolete
Products
TDR, TDC
SPA
SFA
SPA
11
11
11
11
44
44
44
44
-
-
Pipe Thermostats and Flow Switches
Water Flow Switch
Water Immersion Thermostat
Water Immersion Thermostats (manual reset)
SFW
TWK
TWL, TWM
11
11
11
44
44
44
-
-
Pipe Temperature Switch
Strap-on Pipe Thermostat
TSM
11
45
-
-
Outside and Pipe Frost Thermostats
Air Temperature Thermostats
TCL
11
45
-
-
EPT
11
45
-
57
Zone Valve Actuators
Zone Valve Actuators (0-10V)
Zonemaster Actuators (24V)
Zone Valve Actuators (ON/OFF)
Electro-thermic Actuators
AVE
AVU
AY
AVX, AVM
12
12
12
12
46
46
46
49
54
54
-
58
-
Mid Size Valve/actuators
Valve/actuator (0...10V)
Valve Actuators (Pulsed)
AVUE
AVUX, AVUM
12
12
46
46
54
54
58
58
Rotary Actuators
Modulating and Two-position Light Duty Actuators
Rotary Actuators
Spring Return Actuator
RM, XRM
ARX, ARE, ARM
RXS, RES, RMS
12
12, 13
13
47
47
47
54
54
54
58
57, 58
-
Linear Actuators
Self Stroking Intelligent Linear Actuator
‘AL’ Linear Actuators
‘AL-S’ Spring Return Actuators
ALi
ALX, ALE, ALM
ALXS, ALES, ALMS
12
12
12
48
48
48
54
54
54
57
57
57
Small Valves (2, 3 and 4-port)
Zone Valves
Unit Valves
Zone Valves
Electro-thermic Valves
Bonsai Valves
ZY
VEU, MEU, FEU
ZVX
VEX, MEX, FEX
BFB
14, 15
14-16
15
14-16
8
49
49
49
49
31
54
-
58
58, 61
58
-
2-port Valves
Seat Valves
Seat Valves
VZX
VZ, VZF, VSF
14
14
50
50
54
58
59, 60
3-port Valves
Rotary Valves
Rotary Valves
Seat Valves
Seat Valves
MB, MBF
MBX
MZX
MZ, MZF, MJF
15
15
15
15
50
50
50
51
54
54
54
59, 61
61
Satchwell Actuators to Satchwell & Third Party Valves
Linkage Kits
LK, LNK
15
51
-
-
TRANSFORMERS
TR
16
51
-
-
SPARES
–
16
52
-
-
TRANSDUCERS Transducer
Electro Pneumatic Transducer
ACTUATORS
VALVES
LINKAGE KITS
Range
PRICE SUMMARY Alphanumeric List, Satchwell and Drayton
–
22
-
-
-
VALVE SIZING INFORMATION
–
62, 63
-
-
-
SENSOR RESISTANCE CHARTS
–
64
-
-
-
4
Price
List
Product
Selection
Product
Compatibility
Obsolete
Products
VST
VSZ
17
17
66
66
72
72
-
3-port Valves (fan-coil)
Fan Coil Bodies, Threaded
”
”
(for Electro-thermal)
VMT
VMZ
19
19
66
66
72
72
-
4-port Valves (fan-coil)
Fan Coil Bodies, Threaded
”
”
(for Electro-thermal)
VTT
VTZ
20
20
66
66
72
72
-
2-port Valves (plug & seat)
Cast Iron Bodies, Screwed
”
Flanged
VSB, VSBT
VSB.F, VSG, SS-GA, VSS
17
17
66, 67
67, 68
72
72
-
SMALL VALVES 2-port Valves (fan-coil)
Fan Coil Bodies, Threaded
”
”
(for Electro-thermal)
VALVES
ACTUATORS
Spares for Actuators, Controllers, Sensors and Valves
Code
Description
5
PRICE SUMMARY
PRICE SUMMARY
SATCHWELL & DRAYTON PRODUCTS - ALPHANUMERIC PRICE LIST
Code
List Price
04-03-109 . . . . . . . . . . . .83.00
0477-9-241 . . . . . . . . . .160.00
0561-9-220 . . . . . . . . . . .39.00
0561-9-260 . . . . . . . . . .110.00
0561-9-261 . . . . . . . . . .225.00
0563-9-231 . . . . . . . . . . .39.00
0579-1-360 . . . . . . . . . .360.00
0588-9-210 . . . . . . . . . . .39.00
0617-9-410 . . . . . . . . . .130.00
0617-9-411 . . . . . . . . . .148.00
0617-9-412 . . . . . . . . . .163.00
0617-9-413 . . . . . . . . . .163.00
0618-9-210 . . . . . . . . . . .58.00
0618-9-510 . . . . . . . . . .225.00
0618-9-511 . . . . . . . . . .238.00
0618-9-512 . . . . . . . . . .238.00
0623-9-201 . . . . . . . . . . .26.00
0626-9-203 . . . . . . . . . . .82.00
0626-9-204 . . . . . . . . . . .50.00
0626-9-310 . . . . . . . . . .124.00
0626-9-311 . . . . . . . . . .155.00
0626-9-312 . . . . . . . . . . .22.00
0626-9-313 . . . . . . . . . . .20.00
0667-9-201 . . . . . . . . . .112.00
0823-2-801 . . . . . . . . . . .18.00
0837-1-203 . . . . . . . . . . .44.00
0837-1-352 . . . . . . . . . . .18.00
0841-1-201 . . . . . . . . . . .72.00
0841-2-201 . . . . . . . . . . .72.00
0851-2-401 . . . . . . . . . . .22.00
0862-7-702 . . . . . . . . . . . .8.00
0866-1-405 . . . . . . . . . . .27.00
A701 . . . . . . . . . . . . . . . .52.00
A702 . . . . . . . . . . . . . . . .71.00
A703 . . . . . . . . . . . . . . .106.00
A704 . . . . . . . . . . . . . . . .76.00
A705 . . . . . . . . . . . . . . .114.00
AD-8961-220 . . . . . . . . .23.00
AD-8969-202 . . . . . . . . .20.00
ALA1211 . . . . . . . . . . . . .36.00
ALA1751 . . . . . . . . . . . . .51.00
ALE1302 . . . . . . . . . . . .760.00
ALE1352 . . . . . . . . . . . .740.00
ALES1302 . . . . . . . . . . .899.00
ALES1352 . . . . . . . . . . .899.00
ALI1576 . . . . . . . . . . . .610.00
ALI1577 . . . . . . . . . . . .650.00
ALI1676 . . . . . . . . . . . .530.00
ALI1677 . . . . . . . . . . . .615.00
ALM1601 . . . . . . . . . . .479.00
ALMS1601 . . . . . . . . . .769.00
ALMS1651 . . . . . . . . . .769.00
ALX1201 . . . . . . . . . . . .439.00
ALX1251 . . . . . . . . . . . .399.00
ALXS1201 . . . . . . . . . . .769.00
ALXS1251 . . . . . . . . . . .769.00
AM-135 . . . . . . . . . . . . .13.00
ARE2302 . . . . . . . . . . . .179.00
ARE2303 . . . . . . . . . . . .185.00
ARE2304 . . . . . . . . . . . .219.00
ARE2352 . . . . . . . . . . . .149.00
ARE2354 . . . . . . . . . . . .179.00
ARE2355 . . . . . . . . . . . .175.00
ARM2606 . . . . . . . . . . .135.00
ARM2607 . . . . . . . . . . .165.00
ARM2656 . . . . . . . . . . .105.00
ARM2657 . . . . . . . . . . .135.00
ARX2202 . . . . . . . . . . . .129.00
ARX2203 . . . . . . . . . . . .159.00
ARX2252 . . . . . . . . . . . .105.00
ARX2253 . . . . . . . . . . . .135.00
AVA1752 . . . . . . . . . . . . .44.00
AVE0001 . . . . . . . . . . . .145.00
AVE0002 . . . . . . . . . . . .155.00
AVM7301 . . . . . . . . . . . .55.00
AVM7351 . . . . . . . . . . . .55.00
AVU2201 . . . . . . . . . . . .83.00
AVUE4304 . . . . . . . . . . .206.00
AVUE4354 . . . . . . . . . . .215.00
AVUM4601 . . . . . . . . . .196.00
AVUX4202 . . . . . . . . . .181.00
AVX7201 . . . . . . . . . . . . .55.00
AVX7251 . . . . . . . . . . . . .55.00
AY1201 . . . . . . . . . . . . . .61.00
AY1251 . . . . . . . . . . . . . .61.00
AY1301 . . . . . . . . . . . . . .61.00
Code
List Price
AY1351 . . . . . . . . . . . . . .61.00
BCA1601 . . . . . . . . . . . . .49.00
BCA1602 . . . . . . . . . . . . .20.00
BCA9201 . . . . . . . . . . . . .49.00
BCA9202 . . . . . . . . . . . . .39.00
BFB1500 . . . . . . . . . . . . .98.00
BFB1501 . . . . . . . . . . . . .98.00
BFB1506 . . . . . . . . . . . . .92.00
BFB1510 . . . . . . . . . . . . .92.00
BFB1516 . . . . . . . . . . . . .92.00
BFB1520 . . . . . . . . . . . . .92.00
BFB1525 . . . . . . . . . . . . .92.00
BRC-41N-100 . . . . . . . .295.00
BRC-41N-101 . . . . . . . .295.00
BRC-41N-500 . . . . . . . .195.00
BRC-41N-501 . . . . . . . .185.00
BRC-51N-100 . . . . . . . .295.00
BRC-51N-101 . . . . . . . .295.00
BRC-51N-500 . . . . . . . .195.00
BRC-51N-501 . . . . . . . .185.00
BSA1501 . . . . . . . . . . . . .29.00
CSC5252 . . . . . . . . . . . .525.00
CSC5352 . . . . . . . . . . . .550.00
CSM-CORE . . . . . . . . . .250.00
CXR5805 . . . . . . . . . . . .600.00
CXT5605 . . . . . . . . . . . .520.00
CZT5305 . . . . . . . . . . . .650.00
CZU4201 . . . . . . . . . . . .115.00
DC1100 . . . . . . . . . . . . .750.00
DC1100C . . . . . . . . . .1,200.00
DC2100 . . . . . . . . . . . . .299.00
DC2100H . . . . . . . . . .2,250.00
DDC2601 . . . . . . . . . . .120.00
DDCO2602 . . . . . . . . . .963.00
DDH7602 . . . . . . . . . . .356.00
DDH7603 . . . . . . . . . . .276.00
DDP3601 . . . . . . . . . . . .21.00
DDP5601 . . . . . . . . . . .366.00
DDP5610 . . . . . . . . . . .366.00
DDP6601 . . . . . . . . . . .398.00
DDP6610 . . . . . . . . . . .398.00
DDT0001 . . . . . . . . . . . .70.00
DDTH7612 . . . . . . . . . .367.00
DDTH7613 . . . . . . . . . .318.00
DDU0001 . . . . . . . . . . . .20.00
DDU1803 . . . . . . . . . . . .28.00
DDV1201 . . . . . . . . . . .318.00
DOS0002 . . . . . . . . . . . .77.00
DOT0002 . . . . . . . . . . . .70.00
DOW2701 . . . . . . . . . . .276.00
DR3253 . . . . . . . . . . . . . .54.00
DRCO2702 . . . . . . . . . .816.00
DRH7702 . . . . . . . . . . .318.00
DRH7703 . . . . . . . . . . .297.00
DRT3451 . . . . . . . . . . . . .50.00
DRT3453 . . . . . . . . . . . . .52.00
DRT3651 . . . . . . . . . . . . .54.00
DRT3652 . . . . . . . . . . . . .79.00
DRT3801 . . . . . . . . . . . . .85.00
DRT3851 . . . . . . . . . . . . .98.00
DRT4453 . . . . . . . . . . . . .58.00
DRTE2201 . . . . . . . . . . .128.00
DRTE2801 . . . . . . . . . . .185.00
DRTE2851 . . . . . . . . . . .219.00
DRTH7712 . . . . . . . . . .333.00
DRTH7713 . . . . . . . . . .308.00
DRTH8731 . . . . . . . . .1,130.00
DST0001 . . . . . . . . . . . . .64.00
DU4301 . . . . . . . . . . . . .81.00
DUS4302 . . . . . . . . . . . .90.00
DUSF4351 . . . . . . . . . . .149.00
DUSF4352 . . . . . . . . . . .149.00
DWA0001 . . . . . . . . . . . .30.00
DWA0002 . . . . . . . . . . . .73.00
DWA0003 . . . . . . . . . . . .57.00
DWA0004 . . . . . . . . . . . .79.00
DWA0005 . . . . . . . . . . . .22.00
DWT0001 . . . . . . . . . . . .61.00
DWT0002 . . . . . . . . . . . .83.00
EPT7401 . . . . . . . . . . . .330.00
FEU5626 . . . . . . . . . . . . .80.00
FEU5627 . . . . . . . . . . . . .80.00
FEU6414 . . . . . . . . . . . . .52.00
FEU6415 . . . . . . . . . . . . .52.00
Code
List Price
FEU6416 . . . . . . . . . . . . .52.00
FEU6451 . . . . . . . . . . . . .48.00
FEU6452 . . . . . . . . . . . . .48.00
FEU6454 . . . . . . . . . . . . .48.00
FEX7401 . . . . . . . . . . . . .34.00
FLS1502 . . . . . . . . . . . .699.00
HDS9102 . . . . . . . . . . . .134.00
HDS9103 . . . . . . . . . . . .101.00
HDS9201 . . . . . . . . . . . .268.00
HDS9202 . . . . . . . . . . . .206.00
IAC2602 . . . . . . . . . . . . .75.00
IAC420-F . . . . . . . . . . . .599.00
IAC420-P . . . . . . . . . . . .625.00
IAC600-B . . . . . . . . . .1,200.00
IAC-TS . . . . . . . . . . . . . .830.00
KMC3201 . . . . . . . . . . .550.00
LIB-4-485 . . . . . . . . . . .189.00
LK2407 . . . . . . . . . . . . . .58.00
LK2408 . . . . . . . . . . . . . . .4.00
LK2701 . . . . . . . . . . . . . .44.00
LK2702 . . . . . . . . . . . . . .39.00
LK2703 . . . . . . . . . . . . . .49.00
LNK1402 . . . . . . . . . . . . .17.00
LNKFS01 . . . . . . . . . . . .109.00
LNKFS02 . . . . . . . . . . . .109.00
LNKHW01 . . . . . . . . . . . .44.00
LNKHY01 . . . . . . . . . . .109.00
LNKHY02 . . . . . . . . . . .109.00
LNKIN01 . . . . . . . . . . . . .27.00
LNKLS01 . . . . . . . . . . . . .44.00
LON-TERM1 . . . . . . . . . .35.00
LON-TERM2 . . . . . . . . . .35.00
MB1402 . . . . . . . . . . . .120.00
MB1452 . . . . . . . . . . . .126.00
MB1502 . . . . . . . . . . . .142.00
MB1552 . . . . . . . . . . . .200.00
MB1602 . . . . . . . . . . . .244.00
MB1652 . . . . . . . . . . . .282.00
MBF4732 . . . . . . . . . . .411.00
MBF4782 . . . . . . . . . . .488.00
MBF4857 . . . . . . . . . . .505.00
MBX4401 . . . . . . . . . . . .99.00
MBX4451 . . . . . . . . . . .106.00
MBX4501 . . . . . . . . . . .111.00
MBX4551 . . . . . . . . . . .116.00
MBX4601 . . . . . . . . . . .128.00
MBX4651 . . . . . . . . . . .176.00
MEU4422 . . . . . . . . . . . .71.00
MEU4423 . . . . . . . . . . . .71.00
MEU4425 . . . . . . . . . . . .71.00
MEU4626 . . . . . . . . . . .116.00
MEU4627 . . . . . . . . . . .116.00
MEX7301 . . . . . . . . . . . .28.00
MIU4252 . . . . . . . . . . . .599.00
MJF3426 . . . . . . . . . . . .351.00
MJF3427 . . . . . . . . . . . .351.00
MJF3476 . . . . . . . . . . . .409.00
MJF3526 . . . . . . . . . . . .457.00
MJF3576 . . . . . . . . . . . .549.00
MJF3626 . . . . . . . . . . . .609.00
MJF3676 . . . . . . . . . . . .651.00
MMC4601 . . . . . . . . . . .799.00
MMC4701 . . . . . . . . . . .799.00
MNA-C . . . . . . . . . . . . . .89.00
MNA-FLO-1 . . . . . . . . . .41.00
MNA-R10 . . . . . . . . . . .750.00
MN-DK . . . . . . . . . . . . . .89.00
MN-ETH . . . . . . . . . . . .399.00
MNL-10RF2 . . . . . . . . . .425.00
MNL-10RH2 . . . . . . . . .425.00
MNL-10RR2 . . . . . . . . .425.00
MNL-10RS1 . . . . . . . . . .425.00
MNL-10RS2 . . . . . . . . . .425.00
MNL-11RF2 . . . . . . . . . .395.00
MNL-13RF2 . . . . . . . . . .425.00
MNL-15RF2 . . . . . . . . . .425.00
MNL-15RH2 . . . . . . . . .425.00
MNL-15RR2 . . . . . . . . .425.00
MNL-15RS1 . . . . . . . . . .425.00
MNL-15RS2 . . . . . . . . . .425.00
MNL-20RF2 . . . . . . . . . .555.00
MNL-20RH2 . . . . . . . . .555.00
MNL-20RR2 . . . . . . . . .555.00
MNL-20RS1 . . . . . . . . . .555.00
MNL-20RS2 . . . . . . . . . .555.00
MNL-5RF2 . . . . . . . . . . .295.00
List prices are quoted in UK Sterling (£)
CONTROLLI VALVES AND ACTUATORS - ALPHANUMERIC PRICE LIST
Code
List Price
MNL-5RH2 . . . . . . . . . .295.00
MNL-5RR2 . . . . . . . . . .295.00
MNL-5RS1 . . . . . . . . . . .295.00
MNL-5RS2 . . . . . . . . . . .295.00
MNL-C . . . . . . . . . . . . .139.00
MN-LCD-100 . . . . . . . . .375.00
MN-LCDP-100 . . . . . . . .375.00
MNL-FLOW-BAL . . . . . .204.00
MNL-TS-100 . . . . . . . . .894.00
MNL-TSP-100 . . . . . . . .990.00
MNL-V1RV2 . . . . . . . . .395.00
MNL-V2RV2 . . . . . . . . .420.00
MNL-V3RV2 . . . . . . . . .420.00
MN-MER . . . . . . . . . .2,500.00
MN-MER-OUT . . . . . . . .850.00
MNN-30-100 . . . . . . . . .495.00
MNN-44-100 . . . . . . . . .475.00
MNN-50-100 . . . . . . . . .695.00
MNN-62-100 . . . . . . .1,050.00
MNN-COM . . . . . . . . . . .60.00
MNN-MI-100 . . . . . . . .425.00
MNN-RTC . . . . . . . . . . . .65.00
MNN-TS-100 . . . . . . . . .695.00
MNN-TSP-100 . . . . . . . .780.00
MN-S1 . . . . . . . . . . . . . .89.00
MN-S2 . . . . . . . . . . . . . .99.00
MN-S3 . . . . . . . . . . . . .109.00
MN-S4 . . . . . . . . . . . . .125.00
MN-S4-FCS . . . . . . . . . .120.00
MN-S5 . . . . . . . . . . . . .155.00
MN-TK . . . . . . . . . . . . . .55.00
MN-VSCORE . . . . . . . . .500.00
MN-VSLON . . . . . . . . . .350.00
MN-VW100-UK . . . . .1,400.00
MN-VW10K-UK . . . . .5,500.00
MN-VW2K-UK . . . . . .4,000.00
MN-VW500-UK . . . . .2,800.00
MN-VW60K-UK . . . .10,000.00
MN-VWIO-MOD . . . . .1,600.00
MN-VWIO-NCP . . . . .1,100.00
MN-VWION-NCP . . . .1,100.00
MN-VWION-SNP . . . .1,100.00
MN-VWIO-SNP . . . . . .1,100.00
MN-VWP100-UK . . . .4,000.00
MN-VWP10K-UK . . . .8,200.00
MN-VWP2K-UK . . . . .7,000.00
MN-VWP500-UK . . . .5,500.00
MN-VWP60K-UK . . .13,000.00
MZ3402 . . . . . . . . . . . .174.00
MZ3452 . . . . . . . . . . . .188.00
MZ3501 . . . . . . . . . . . .215.00
MZ3551 . . . . . . . . . . . .232.00
MZ3601 . . . . . . . . . . . .337.00
MZ3651 . . . . . . . . . . . .455.00
MZF3729 . . . . . . . . . . .865.00
MZF3779 . . . . . . . . . .1,138.00
MZF3854 . . . . . . . . . .1,415.00
MZF3904 . . . . . . . . . .1,688.00
MZF3958 . . . . . . . . . .2,097.00
MZX4402 . . . . . . . . . . .126.00
MZX4452 . . . . . . . . . . .137.00
MZX4501 . . . . . . . . . . .155.00
MZX4551 . . . . . . . . . . .185.00
MZX4601 . . . . . . . . . . .203.00
MZX4651 . . . . . . . . . . .245.00
RB1 . . . . . . . . . . . . . . . . .64.00
RB2 . . . . . . . . . . . . . . . . .64.00
RES7354 . . . . . . . . . . . .374.00
RES7355 . . . . . . . . . . . .185.00
RM3601 . . . . . . . . . . . .379.00
RMS7654 . . . . . . . . . . .361.00
RMS7655 . . . . . . . . . . .387.00
RMS7656 . . . . . . . . . . .237.00
RMS7657 . . . . . . . . . . .237.00
RPW4425 . . . . . . . . . . .169.00
RXS7254 . . . . . . . . . . . .361.00
RXS7255 . . . . . . . . . . . .387.00
RXS7256 . . . . . . . . . . . .232.00
RXS7257 . . . . . . . . . . . .258.00
SFA1451 . . . . . . . . . . . . .83.00
SFW1251 . . . . . . . . . . . .98.00
SPA1401 . . . . . . . . . . . . .46.00
SPA1402 . . . . . . . . . . . . .46.00
SPA1501 . . . . . . . . . . . .140.00
SPA1502 . . . . . . . . . . . .140.00
SPA1503 . . . . . . . . . . . .175.00
Code
List Price
SPA1504 . . . . . . . . . . . .175.00
SPA1505 . . . . . . . . . . . . .73.00
SPA1506 . . . . . . . . . . . . .73.00
SVT4201 . . . . . . . . . . . .499.00
SVT4251 . . . . . . . . . . . .549.00
TCL1601 . . . . . . . . . . . . .65.00
TCL1602 . . . . . . . . . . . . .62.00
TCL1603 . . . . . . . . . . . . .62.00
TDC2202 . . . . . . . . . . . . .57.00
TDR2201 . . . . . . . . . . . . .54.00
TR1 . . . . . . . . . . . . . . . . .52.00
TR2 . . . . . . . . . . . . . . . . .71.00
TR3 . . . . . . . . . . . . . . . . .96.00
TR4 . . . . . . . . . . . . . . . .132.00
TR5 . . . . . . . . . . . . . . . .214.00
TSM2501 . . . . . . . . . . . .26.00
TWK2301 . . . . . . . . . . . .57.00
TWL2302 . . . . . . . . . . . .52.00
TWM2401 . . . . . . . . . . . .84.00
URC-41N-100 . . . . . . . .195.00
URC-41N-101 . . . . . . . .195.00
URC-41N-102 . . . . . . . .195.00
URC-41N-103 . . . . . . . .195.00
URC-51N-100 . . . . . . . .210.00
URC-51N-101 . . . . . . . .210.00
URC-51N-102 . . . . . . . .210.00
URC-51N-103 . . . . . . . .220.00
URC-IR-100 . . . . . . . . . .450.00
URC-SET-100 . . . . . . . . .120.00
VEU4414 . . . . . . . . . . . . .71.00
VEU4415 . . . . . . . . . . . . .71.00
VEU4416 . . . . . . . . . . . . .71.00
VEU4626 . . . . . . . . . . . .116.00
VEX7201 . . . . . . . . . . . . .27.00
VSF1476 . . . . . . . . . . . .462.00
VSF1526 . . . . . . . . . . . .529.00
VSF1576 . . . . . . . . . . . .611.00
VSF1626 . . . . . . . . . . . .741.00
VSF1676 . . . . . . . . . . . .801.00
VSF2426 . . . . . . . . . . . .455.00
VSF2427 . . . . . . . . . . . .455.00
VSF2428 . . . . . . . . . . . .455.00
VSF2429 . . . . . . . . . . . .455.00
VSF2430 . . . . . . . . . . . .455.00
VV-LITE . . . . . . . . . . .1,000.00
VV-LITE-TO-STD . . . . .1,100.00
VV-STANDARD . . . . . .2,000.00
VZ1401 . . . . . . . . . . . . .174.00
VZ1402 . . . . . . . . . . . . .174.00
VZ1403 . . . . . . . . . . . . .174.00
VZ1404 . . . . . . . . . . . . .174.00
VZ1451 . . . . . . . . . . . . .188.00
VZ2501 . . . . . . . . . . . . .215.00
VZ2551 . . . . . . . . . . . . .232.00
VZ2601 . . . . . . . . . . . . .337.00
VZ2651 . . . . . . . . . . . . .560.00
VZF1727 . . . . . . . . . . . .783.00
VZF1777 . . . . . . . . . . .1,057.00
VZF1852 . . . . . . . . . . .1,468.00
VZF1902 . . . . . . . . . . .1,605.00
VZF1954 . . . . . . . . . . .2,015.00
VZX4404 . . . . . . . . . . . .114.00
VZX4451 . . . . . . . . . . . .124.00
VZX4501 . . . . . . . . . . . .142.00
VZX4551 . . . . . . . . . . . .169.00
VZX4601 . . . . . . . . . . . .190.00
VZX4651 . . . . . . . . . . . .231.00
WP-TECH-32 . . . . . . . .3,000.00
WP-TECH-CD-E-32 . . . . .250.00
XRM3201 . . . . . . . . . . .379.00
ZVX4201 . . . . . . . . . . . . .61.00
ZVX4202 . . . . . . . . . . . . .66.00
ZVX4203 . . . . . . . . . . . . .72.00
ZVX4301 . . . . . . . . . . . . .48.00
ZVX4302 . . . . . . . . . . . . .64.00
ZVX4303 . . . . . . . . . . . . .70.00
ZVX4401 . . . . . . . . . . . . .81.00
ZY1201 . . . . . . . . . . . . . .33.00
ZY1202 . . . . . . . . . . . . . .33.00
ZY1203 . . . . . . . . . . . . . .33.00
ZY1204 . . . . . . . . . . . . . .37.00
ZY1205 . . . . . . . . . . . . . .37.00
ZY1206 . . . . . . . . . . . . . .37.00
ZY1301 . . . . . . . . . . . . . .33.00
ZY1302 . . . . . . . . . . . . . .33.00
ZY1303 . . . . . . . . . . . . . .33.00
ZY1304 . . . . . . . . . . . . . .37.00
ZY1305 . . . . . . . . . . . . . .37.00
ZY1306 . . . . . . . . . . . . . .37.00
Code
List Price
244 . . . . . . . . . . . . . . . .185.00
245 . . . . . . . . . . . . . . . .195.00
246 . . . . . . . . . . . . . . . .195.00
51938 . . . . . . . . . . . . . . .32.00
52554 . . . . . . . . . . . . . .£27.00
52980 . . . . . . . . . . . . . . .47.00
260915 . . . . . . . . . . . . . .47.00
3V-AA100 . . . . . . . . . .4,716.00
3V-AA125 . . . . . . . . . .6,407.00
3VAA25 . . . . . . . . . . .1,346.00
3V-AA25I . . . . . . . . . .1,346.00
3V-AA25R . . . . . . . . .1,346.00
3V-AA32 . . . . . . . . . .1,609.00
3V-AA40 . . . . . . . . . .1,859.00
3V-AA50 . . . . . . . . . .2,202.00
3V-AA65 . . . . . . . . . .2,691.00
3V-AA80 . . . . . . . . . .3,179.00
3V-AACP100 . . . . . . . .5,811.00
3V-AACP100B . . . . . .5,811.00
3V-AACP125 . . . . . . . .7,826.00
3V-AACP125B . . . . . .7,826.00
3V-AACP25 . . . . . . . .1,951.00
3V-AACP25B . . . . . . .1,951.00
3V-AACP25I . . . . . . . .1,951.00
3V-AACP25IB . . . . . . .1,951.00
3V-AACP25R . . . . . . .1,951.00
3V-AACP25RB . . . . . .1,951.00
3V-AACP32 . . . . . . . .2,293.00
3V-AACP32B . . . . . . .2,293.00
3V-AACP40 . . . . . . . .2,560.00
3V-AACP40B . . . . . . .2,557.00
3V-AACP50 . . . . . . . .2,903.00
3V-AACP50B . . . . . . .2,903.00
3V-AACP65 . . . . . . . .3,446.00
3V-AACP65B . . . . . . .3,446.00
3V-AACP80 . . . . . . . .4,098.00
3V-AACP80B . . . . . . .4,098.00
3V-GA100 . . . . . . . . .2,631.00
3V-GA125 . . . . . . . . .4,292.00
3V-SA80 . . . . . . . . . . .1,795.00
AF22 . . . . . . . . . . . . . . .159.00
AG21 . . . . . . . . . . . . . . .27.00
AG31 . . . . . . . . . . . . . . .27.00
D36 . . . . . . . . . . . . . . . .47.00
D5 . . . . . . . . . . . . . . . . .47.00
DMVL . . . . . . . . . . . . . . .73.00
DS-AA100 . . . . . . . . .5,200.00
DS-AA125 . . . . . . . . .6,789.00
DS-AA150 . . . . . . . . .8,967.00
DS-AA32 . . . . . . . . . .1,796.00
DS-AA40 . . . . . . . . . .2,129.00
DS-AA50 . . . . . . . . . .2,524.00
DS-AA65 . . . . . . . . . .2,921.00
DS-AA80 . . . . . . . . . .3,586.00
DS-AACP100 . . . . . . .6,690.00
DS-AACP100B . . . . . .6,690.00
DS-AACP125 . . . . . . .8,469.00
DS-AACP125B . . . . . .8,469.00
DS-AACP150 . . . . . .10,891.00
DS-AACP150B . . . . .10,891.00
DS-AACP32 . . . . . . . .2,550.00
DS-AACP32B . . . . . . .2,550.00
DS-AACP32R . . . . . . .2,550.00
DS-AACP32RB . . . . . .2,550.00
DS-AACP40 . . . . . . . .2,875.00
DS-AACP40B . . . . . . .2,875.00
DS-AACP50 . . . . . . . .3,358.00
DS-AACP50B . . . . . . .3,358.00
DS-AACP65 . . . . . . . .3,930.00
DS-AACP65B . . . . . . .3,930.00
DS-AACP80 . . . . . . . .4,695.00
DS-AACP80B . . . . . . .4,695.00
MDL22 . . . . . . . . . . . . .490.00
MDL24 . . . . . . . . . . . . .502.00
MDL26 . . . . . . . . . . . . .541.00
MDL42 . . . . . . . . . . . . .490.00
MDL44 . . . . . . . . . . . . .502.00
MDL46 . . . . . . . . . . . . .544.00
MDL52 . . . . . . . . . . . . .599.00
MDL54 . . . . . . . . . . . . .685.00
Code
List Price
MDL56 . . . . . . . . . . . . .649.00
MVA21 . . . . . . . . . . . . . .30.00
MVA23 . . . . . . . . . . . . . .28.00
MVA41 . . . . . . . . . . . . . .30.00
MVA43 . . . . . . . . . . . . . .28.00
MVB26 . . . . . . . . . . . . .256.00
MVB46 . . . . . . . . . . . . .237.00
MVB52 . . . . . . . . . . . . .314.00
MVB56 . . . . . . . . . . . . .307.00
MVBC . . . . . . . . . . . . . . .32.00
MVBHT . . . . . . . . . . . . . .19.00
MVBPA2 . . . . . . . . . . . . .57.00
MVL26 . . . . . . . . . . . . .603.00
MVL46 . . . . . . . . . . . . .603.00
MVL46A . . . . . . . . . . . .703.00
MVL46C . . . . . . . . . . . .703.00
MVL56 . . . . . . . . . . . . .694.00
MVL56A . . . . . . . . . . . .832.00
MVL56C . . . . . . . . . . . .832.00
MVLPA2 . . . . . . . . . . . . .85.00
MVLPA4 . . . . . . . . . . . . .85.00
MVLPA4M . . . . . . . . . . . .85.00
MVT44 . . . . . . . . . . . . . .73.00
MVT56 . . . . . . . . . . . . .132.00
P-1000-1 . . . . . . . . . . . . .85.00
P-140-1 . . . . . . . . . . . . . .85.00
SH222 . . . . . . . . . . . . . .481.00
SH242 . . . . . . . . . . . . . .506.00
SH522 . . . . . . . . . . . . . .593.00
SS-AA15 . . . . . . . . . . . .797.00
SS-AA15R . . . . . . . . . . .797.00
SS-AA20 . . . . . . . . . . . .864.00
SS-AA25 . . . . . . . . . . . .953.00
SS-AA32 . . . . . . . . . . .1,115.49
SS-AA40 . . . . . . . . . . .1,296.00
SS-AA50 . . . . . . . . . . .1,551.00
SS-AA65 . . . . . . . . . . .1,971.00
SS-AA80 . . . . . . . . . . .2,549.00
SS-AACP15 . . . . . . . . .1,298.00
SS-AACP15B . . . . . . . .1,298.00
SS-AACP15R . . . . . . . .1,298.00
SS-AACP15RB . . . . . . .1,298.00
SS-AACP20 . . . . . . . . .1,375.00
SS-AACP20B . . . . . . . .1,375.00
SS-AACP25 . . . . . . . . .1,495.00
SS-AACP25B . . . . . . . .1,496.00
SS-AACP32 . . . . . . . . .1,783.00
SS-AACP32B . . . . . . . .1,782.00
SS-AACP40 . . . . . . . . .1,978.00
SS-AACP40B . . . . . . . .1,978.00
SS-AACP50 . . . . . . . . .2,260.00
SS-AACP50B . . . . . . . .2,260.00
SS-AACP65 . . . . . . . . .2,875.00
SS-AACP65B . . . . . . . .2,875.00
SS-AACP80 . . . . . . . . .3,615.00
SS-AACP80B . . . . . . . .3,615.00
SS-GA100 . . . . . . . . . .1,820.00
SS-GA15 . . . . . . . . . . . .358.00
SS-GA15R . . . . . . . . . . .358.00
SS-GA20 . . . . . . . . . . . .362.00
SS-GA25 . . . . . . . . . . . .381.00
SS-GA32 . . . . . . . . . . . .459.00
SS-GA40 . . . . . . . . . . . .508.00
SS-GA50 . . . . . . . . . . . .729.00
SS-GA65 . . . . . . . . . . . .950.00
SS-GA80 . . . . . . . . . . .1,198.00
ST404 . . . . . . . . . . . . . .373.00
ST405 . . . . . . . . . . . . . .280.00
VBG100 . . . . . . . . . . .1,751.00
VBG125 . . . . . . . . . . .2,208.00
VBG150 . . . . . . . . . . .2,687.00
VBG80 . . . . . . . . . . . .1,364.00
VBS25 . . . . . . . . . . . . . .610.00
VBS251 . . . . . . . . . . . . .610.00
VBS252R . . . . . . . . . . . .610.00
VBS32 . . . . . . . . . . . . . .713.00
VBS40 . . . . . . . . . . . . . .783.00
VBS50 . . . . . . . . . . . .1,104.00
VBS65 . . . . . . . . . . . .1,392.00
VFG10-100 . . . . . . . . . .420.00
VFG10-125 . . . . . . . . . .459.00
Code
List Price
VFG10-150 . . . . . . . . . .591.00
VFG10-200 . . . . . . . . . .844.00
VFG10-40 . . . . . . . . . . .369.00
VFG10-50 . . . . . . . . . . .366.00
VFG10-65 . . . . . . . . . . .369.00
VFG10-80 . . . . . . . . . . .390.00
VMB1 . . . . . . . . . . . . . .103.00
VMB11 . . . . . . . . . . . . .103.00
VMB11F . . . . . . . . . . . .190.00
VMB15 . . . . . . . . . . . . .103.00
VMB15F . . . . . . . . . . . .190.00
VMB16100 . . . . . . . . . .838.00
VMB16125 . . . . . . . . .1,419.00
VMB16150 . . . . . . . . .1,902.00
VMB1665 . . . . . . . . . . .512.00
VMB1680 . . . . . . . . . . .610.00
VMB1F . . . . . . . . . . . . .190.00
VMB2 . . . . . . . . . . . . . .103.00
VMB2F . . . . . . . . . . . . .190.00
VMB3 . . . . . . . . . . . . . .108.00
VMB3F . . . . . . . . . . . . .199.00
VMB4 . . . . . . . . . . . . . .117.00
VMB4F . . . . . . . . . . . . .210.00
VMB5 . . . . . . . . . . . . . .151.00
VMB5F . . . . . . . . . . . . .235.00
VMB6 . . . . . . . . . . . . . .184.00
VMB6F . . . . . . . . . . . . .259.00
VMB8 . . . . . . . . . . . . . .227.00
VMB8A . . . . . . . . . . . . .227.00
VMB8AF . . . . . . . . . . . .298.00
VMB8F . . . . . . . . . . . . .298.00
VMB9F . . . . . . . . . . . . .564.00
VMBT3 . . . . . . . . . . . . .131.00
VMBT4 . . . . . . . . . . . . .144.00
VMBT5 . . . . . . . . . . . . .163.00
VMBT6 . . . . . . . . . . . . .184.00
VMS25 . . . . . . . . . . . . .704.00
VMS251 . . . . . . . . . . . .704.00
VMS25R . . . . . . . . . . . .704.00
VMS32 . . . . . . . . . . . . .886.00
VMS40 . . . . . . . . . . . . .886.00
VMS50 . . . . . . . . . . . .1,115.00
VMS65 . . . . . . . . . . . .1,390.00
VMT09 . . . . . . . . . . . . . .35.00
VMT1 . . . . . . . . . . . . . . .35.00
VMT10 . . . . . . . . . . . . . .35.00
VMT11 . . . . . . . . . . . . . .35.00
VMT12 . . . . . . . . . . . . . .35.00
VMT13 . . . . . . . . . . . . . .35.00
VMT2 . . . . . . . . . . . . . . .44.00
VMZ09B . . . . . . . . . . . . .35.00
VMZ10B . . . . . . . . . . . . .35.00
VMZ11B . . . . . . . . . . . . .35.00
VMZ12B . . . . . . . . . . . . .35.00
VMZ13B . . . . . . . . . . . . .35.00
VMZ1B . . . . . . . . . . . . . .35.00
VMZ2B . . . . . . . . . . . . . .44.00
VSB1 . . . . . . . . . . . . . . .103.00
VSB11 . . . . . . . . . . . . . .103.00
VSB11F . . . . . . . . . . . . .168.00
VSB15 . . . . . . . . . . . . . .106.00
VSB15F . . . . . . . . . . . . .173.00
VSB1F . . . . . . . . . . . . . .173.00
VSB2 . . . . . . . . . . . . . . .109.00
VSB2F . . . . . . . . . . . . . .173.00
VSB3 . . . . . . . . . . . . . . .108.00
VSB3F . . . . . . . . . . . . . .182.00
VSB4 . . . . . . . . . . . . . . .117.00
VSB4F . . . . . . . . . . . . . .194.00
VSB5 . . . . . . . . . . . . . . .151.00
VSB5F . . . . . . . . . . . . . .210.00
VSB6 . . . . . . . . . . . . . . .184.00
VSB6F . . . . . . . . . . . . . .236.00
VSB8 . . . . . . . . . . . . . . .228.00
VSB8A . . . . . . . . . . . . . .228.00
VSB8AF . . . . . . . . . . . . .276.00
VSB8F . . . . . . . . . . . . . .276.00
VSB9F . . . . . . . . . . . . . .595.00
VSBT3 . . . . . . . . . . . . . .132.00
VSBT4 . . . . . . . . . . . . . .144.00
VSBT5 . . . . . . . . . . . . . .164.00
List prices are quoted in UK Sterling (£)
22
23
Code
List Price
VSBT6 . . . . . . . . . . . . . .184.00
VSG100 . . . . . . . . . . . . .886.00
VSG125 . . . . . . . . . . .1,537.00
VSG150 . . . . . . . . . . .2,239.00
VSG65 . . . . . . . . . . . . . .541.00
VSG80 . . . . . . . . . . . . . .681.00
VSS25 . . . . . . . . . . . . . .633.00
VSS251 . . . . . . . . . . . . .633.00
VSS25R . . . . . . . . . . . . .633.00
VSS32 . . . . . . . . . . . . . .835.00
VSS40 . . . . . . . . . . . . . .982.00
VSS50 . . . . . . . . . . . .1,188.00
VSS65 . . . . . . . . . . . .1,495.00
VST09 . . . . . . . . . . . . . . .33.00
VST1 . . . . . . . . . . . . . . . .33.00
VST10 . . . . . . . . . . . . . . .33.00
VST11 . . . . . . . . . . . . . . .33.00
VST12 . . . . . . . . . . . . . . .33.00
VST13 . . . . . . . . . . . . . . .33.00
VST2 . . . . . . . . . . . . . . . .41.00
VST21 . . . . . . . . . . . . . . .41.00
VSZ09B . . . . . . . . . . . . . .33.00
VSZ10B . . . . . . . . . . . . . .33.00
VSZ11B . . . . . . . . . . . . . .33.00
VSZ12B . . . . . . . . . . . . . .33.00
VSZ13B . . . . . . . . . . . . . .33.00
VSZ1B . . . . . . . . . . . . . . .33.00
VSZ21B . . . . . . . . . . . . . .41.00
VSZ2B . . . . . . . . . . . . . . .41.00
VTT09 . . . . . . . . . . . . . . .37.00
VTT1 . . . . . . . . . . . . . . . .37.00
VTT10 . . . . . . . . . . . . . . .37.00
VTT11 . . . . . . . . . . . . . . .37.00
VTT12 . . . . . . . . . . . . . . .37.00
VTT13 . . . . . . . . . . . . . . .37.00
VTT2 . . . . . . . . . . . . . . . .47.00
VTT21 . . . . . . . . . . . . . . .47.00
VTZ09B . . . . . . . . . . . . . .37.00
VTZ10B . . . . . . . . . . . . . .37.00
VTZ11B . . . . . . . . . . . . . .37.00
VTZ12B . . . . . . . . . . . . . .37.00
VTZ13B . . . . . . . . . . . . . .37.00
VTZ1B . . . . . . . . . . . . . . .37.00
VTZ21B . . . . . . . . . . . . . .47.00
VTZ2B . . . . . . . . . . . . . . .47.00
Satchwell MicroNet
NOTES
PRODUCT SELECTION
Software
VisiView is a state-of-the-art graphical user interface for
MicroNet and Satchnet networking controllers, utilising
the latest web technology to give users total visibility of
heating, ventilation and air conditioning installations in
their buildings.
VisiView
VV-LITE
VV-STANDARD
VV-LITE-TO-STD
VisiView, provides fully flexible access to system
parameters, status and performance via users’ own PC
browsers. Up to three users can log on concurrently.
Installed on a simple plug-and-play basis, VisiView uses
industry-standard Windows XP Pro and Microsoft Explorer
software.
FEATURES (cont)
• Graphical User Interface (GUI) using Internet Explorer
• Scalable Vector Graphics (SVG) enable dynamically generated, high-quality
graphics from real-time data
• Comprehensive library of SVG objects provides graphical controls for a wide range
of schemes
• Provides visualisation of live schemes from any location
connected to the Internet/Intranet
• Resolution independent graphics rendering
• End user requires Web browser only
• Alarms: value and state based with alarms transmitted by email
• Only authorised users can log on to VisiView projects
• Open architecture: can stream third-party data
• Live information, streamed direct to the browser
• User interface available in multiple languages
• Uses VisiSat Points List as basis for project design
• Any number of users (clients) possible, with up to 3 concurrent users
• MicroNet data source provided as standard
• Administrator configuration of users, projects and communications
• Supports MicroNet, IAC and MMC controllers
• Security/Access: access rights can extend to individual rights on each Point of data
• Logging: both historical and live-trend display
MicroNet View is a software platform that provides an
intuitive, graphical interface for network-level supervisory
and control functions. MicroNet View works on any of the
MicroNet network options, LONWORKS® FTT-10 Free Topology,
NCP (Native Communications Protocol), and ARCNET, and
works with the MicroNet family. MicroNet View supports
also Satchnet range products such as IAC controllers and
third party products such as chillers, boilers and access
control systems.
FEATURES
MicroNet View
• Real-time data on active, multi-media
graphical displays
• Provides intuitive operation via customised
control panels
• Support for DDE, and fast DDE standards
• Supports the use of bitmaps, photos, and other
graphic formats when designing the network
reporting display
• Comprehensive logging and alarm
management utilities
Description
Type
MN-VW100-UK
MN-VW500-UK
MN-VW2K-UK
MN-VW10K-UK
MN-VW60K-UK
MicroNet View
”
”
”
”
100 tag, English version
500 tag, English version
2,000 tag, English version
10,000 tag, English version
60,000 tag, English version
MN-VWIO-NCP
MN-VWIO-SNP
MN-VWION-NCP
MN-VWION-SNP
I/O-servers
(dongles)
”
”
NCP/ARCNET I/O-server, dongle
Satchnet I/O-server, dongle
NCP/ARCNET I/O-server, for existing dongle
Satchnet I/O-server, for existing dongle
MN-VWP100-UK
MN-VWP500-UK
MN-VWP2K-UK
MN-VWP10K-UK
MN-VWP60K-UK
MicroNet View Pro
(development)
”
”
”
100 tag, English version
500 tag, English version
2,000 tag, English version
10,000 tag, English version
60,000 tag, English version
Data Sheet 10.201
HARDWARE SPECIFICATIONS
See data sheet for minimum hardware requirements.
ACCESSORIES
ECH-37200
ECH-42100
ECH-42102
ECH-42105
ECH-48222
ECH-73403
ECH-74401
WPA-LON-1
WPA-LON-2
SPI-1111
SPI-1112
MicroNet View Pro
• Allows graphics generation and development of
the application
• Powerful scripting editor for creating and performing
system tasks
• Use of ActiveX® Controls and Wizards makes the
system configuration easy
• Allows monitoring and editing of system variables
24
up to 250 points, 2 concurrent clients
up to 2000 points, 3 concurrent clients
HARDWARE SPECIFICATIONS
See data sheet for minimum hardware requirements.
FEATURES
VisiSat™2
Configuration
Tool
Type
VisiView Lite
VisiView Standard
VisiView Lite to
Standard Upgrade
Data Sheet 10.204
VisiView is ideal for smaller sites (and networks of sites)
where cost-effective solutions are required. It is
particularly effective where maintenance people require
remote access via a standard browser, and where ease of
installation and engineering is critical.
MicroNet
View
Description
This software is a cohesive, flexible, system engineering tool
compatible with Microsoft Windows 2000 Professional and
Windows XP. It uses Visio 2000 or Visio 2002 32-bit drawing
interface for graphic representation of control applications
and control objects. With this configuration tool, a designer
can customise an application to match specific project
requirements then loads the application to a stand alone or
networked controller.
LNS DDE server edition
LPR-10 Router Module TP/FT-10 to TP/FT-10
LPR-12 Router Module TP/FT-10 to TPXF-1250
LPR-15 Router Module TP/XF-1250 to TP/XF-1250
Type 2D DIN Base Plate
PCLTA-10/TP-1250 ISA (16-bit) Desktop interface
PCLTA-20/FT-10 PCI (32-bit) Desktop interface
PC ISA Card (16-bit) to connect PCs to LONWORKS FTT-10 network
PCMCIA Card to connect Laptop PCs to LONWORKS FTT-10 network
SPI Main Software (with dongle)
SPI Main Software (for existing dongle)
Description
MN-VSCORE
MN-VSLON
VisiSat 2
”
Type
Configuration tool, core software
Plug-in option for LON devices
Data Sheet 10.202
HARDWARE SPECIFICATIONS
See data sheet for minimum hardware requirements.
ACCESSORIES
LIB-4-485
WPA-LON-1
WPA-LON-2
ECH-33100-10
ECH-37000
ECH-37100
ECH-73403
ECH-74401
FEATURES
• Runs under Visio 2000 or Visio 2002
• Compatible with Windows 2000 Professional or
Windows xp
• Controllers are programmed using graphical objects in
"Bubbleland"
• Powerful and intuitive configuration of interfaces
• Unique mechanism to change LON controller profiles
• 'Custom' object creation for standard repeated
applications
• Configuration report generation
• Autogeneration of wiring diagrams
• Multiple trends on single page.
25
RS 232/RS 485 Converter to connect PC to NCP network
PCISA Card (16-bit) to connect PCs to LONWORKS FTT-10 network
PC (PCMCIA) Card to connect Laptop PCs to LONWORKS FTT-10 network
LonManager PCC-10 Protocol analyzer
LonMaker for Windows Integration Tool Siebe edition
LonMaker Credits (1 unit = 1 credit)
PCLTA-10/TP-1250 ISA (16-bit) Desktop interface
PCLTA-20/FT-10 PCI (32-bit) Desktop interface
PRODUCT SELECTION
Software
Satchwell MicroNet
WP Tech is a Windows 2000 compatible program used to
create and download control logic applications to MicroNet
LONMARK® controllers. The program uses a Visio 32-bit
drawing interface for a graphical representation of
applications control logic.
CSM Tool
Description
Type
WP-TECH-CD-E-32
Workplace Tech CD-Rom
WP-TECH-32
Workplace Tech Licence
Configuration tool files for
LONMARK controllers
Software unlock codes and licence
Data Sheet –
FEATURES/BENEFITS
• Easy operation
– modify existing pre-engineered applications
– engineer a complete custom application
– compile and download control logic applications
to controllers
– examine controller memory usage required by
an application
• Object-oriented programming environment
• Programmable shapes
• Visio drawing environment
HARDWARE SPECIFICATIONS
See data sheet for minimum hardware requirements.
ACCESSORIES
WPA-LON-1
WPA-LON-2
ECH-33100-10
ECH-37000
ECH-37100
ECH-73403
ECH-74401
Remote Alarm Manager is a powerful software package for
routing alarm information to management and service
personnel. It integrates seamlessly to Micronet View and
includes comprehensive alarm tracking and history.
Remote Alarm
Manager
MN 50
PC ISA Card (16-bit) to connect PCs to LONWORKS FTT-10 network
PC (PCMCIA) Card to connect Laptop PCs to LONWORKS FTT-10 network
LonManager PCC-10 Protocol analyzer
LonMaker for Windows Integration Tool Siebe edition
LonMaker Credits (1 unit = 1 credit)
PCLTA-10/TP-1250 ISA (16-bit) Desktop interface
PCLTA-20/FT-10 PCI (32-bit) Desktop interface
Description
Programmable
Controllers
System software, includes 1 output driver
Output drivers (see data sheet)
HARDWARE SPECIFICATIONS
See data sheet for minimum hardware requirements.
FEATURES (cont)
• Core software includes Web and WAP interfaces
• Self-monitoring of system hardware and software
• Console for system configuration and full alarm history
FEATURES
• Alarm information collected automatically from
Micronet View
• Output drivers to fax, remote printer, Web pages,
SMS messaging or E-mail.
MN 100, 150
& 200
Programmable
controllers
The Commissioning, Service and Maintenance Tool (CSM Tool)
is an engineering tool used by field engineers to modify (and
monitor) a standard MicroNet system, by downloading VisiSat
applications to one or more selected bus-du-jour (and LON)
controllers and changing the properties of those controllers to
suit the local requirements. All controllers supported by
VisiSat are supported by the CSM Tool. The CSM Tool is based
on VisiSat COM objects which enable communications,
downloading of schemes and editing of properties. It is a
stand-alone application intended to be run on a laptop
connected to a Satchnet (IAC), NCP ARCNET® or LON network
via a communications server. There is no need for Microsoft®
Visio to be installed on the same computer. The CSM Tool is
compatible with Microsoft® Windows® XP Professional and
Windows 2000 Professional (Windows XP preferred).
Description
CSM-CORE
CSM Tool
Type
Commissioning, Service and
Maintenance Tool
Data Sheet 10.203
HARDWARE SPECIFICATIONS
See data sheet for minimum hardware requirements
Controllers (LONM
FEATURES (cont)
• Supports all controllers, network management and display devices
supported by VisiSat
Controllers with
Integral Actuator
)
The MNL-11RF2 is an interoperable, LONMARK Compliant
Controller. When programmed using WorkPlace Tech Tool it
provides control for fan coil applications. The controller
conforms to the LONMARK fan coil unit functional profile
(8020), for open communication and interoperability with
third party LONMARK devices - providing greater freedom in
system design.
Fan Coil Unit
Controller
The controller can function in a stand-alone mode or as part
of a LONWORKS FTT-10 free topology network.
MNL-11RF2
Controller
with Fan Coil Profile
LONMARK profile
Fan Coil
Inputs/outputs
3 x universal input (UI)
4 x digital outputs (DO)
1 x 230Vac, 3A relay
MNL-13RF2
with Fan Coil Profile
Fan Coil
3 x universal input (UI)
4 x digital outputs (DO)
3 x 230Vac, 3A relays
Data Sheet – F26886/7
Power supply - 24Vac, 50/60Hz
Protection class - IP 20
Mounting - Wall mounted or DIN rail
Sensor inputs - MN Sx digital sensor link
Universal inputs - 10k resistance, 1kΩ Balco input, 1kΩ Platinum input, 1k resistance,
10kΩ thermistor with 11k shunt resistors, voltage, current, digital input
Digital outputs - MN 11: 1 x relay output, 4 x 24Vac triac outputs
MN 13: 3 x relay outputs, 4 x 24Vac triac outputs
FEATURES
• LONTalk® FTT-10 support
• LONMARK® fan coil profile 8020 support
• Fully programmable using WorkPlace Tech Tool
• S-link support
• On board LED indication without cover removal
• Built-in LON jack, for connection to a LON network
ACCESSORIES – see page 28
26
FEATURES
• LONMARK compliant, programmable
• Capability to function in stand-alone mode or as part
of a LONWORKS FTT-10 Free Topology communications
network
• Proportional (P), Proportional Plus Integral (PI), and
Proportional Plus Integral and Derivative (PID) control
for cooling and heating
• LED indication
• Plenum-rated enclosure
• Satellite profile allows controller to be used in a
broad range of applications
Power supply - 20.4...30Vac, 50/60Hz
Consumption - 84VA max : 12VA plus DO loads (24Vac each)
Surge immunity compliance - ANSI C62.41 (IEEE-587, Category A & B)
Protection class - IP 20
Mounting - 35mm DIN rail or panel
Sensor inputs - MN Sx digital sensor link
Digital input - Input type: Dry contact
Universal inputs - 10k resistance, 1kΩ Balco input, 1kΩ Platinum input, 1k resistance,
10kΩ thermistor with 11k shunt resistors, voltage, current, digital input
Digital outputs - Relay outputs: SW24H1, 2 & 3 current ratings
LONMARK profile
Fan Coil
Heat Pump
Rooftop
Satellite
Inputs/outputs
1 x digital input (DI)
1 x universal input (UI)
3 x digital outputs (DO)
ACCESSORIES – see page 28
Controller
MNL-10RF2 with Fan Coil Profile
MNL-10RH2 with Heat Pump Profile
MNL-10RR2 with Roof Top Profile
MNL-10RS2 with Satellite Profile
MNL-15RF2 with Fan Coil Profile
MNL-15RH2 with Heat Pump Profile
MNL-15RR2 with Roof Top Profile
MNL-15RS2 with Satellite Profile
MNL-20RF2 with Fan Coil Profile
MNL-20RH2 with Heat Pump Profile
MNL-20RR2 with Roof Top Profile
MNL-20RS2 with Satellite Profile
Data Sheet 10.100
All controllers use the same physical packaging, but differ in
the onboard I/O points they provide.
FEATURES
• LONMARK compliant, programmable
• Capability to function in stand-alone mode or as
part of a LONWORKS FTT-10 Free Topology
communications network
• Proportional (P), Proportional Plus Integral (PI), and
Proportional Plus Integral and Derivative (PID) control
for cooling and heating
• LED indication
• Plenum-rated enclosure
• Satellite profile allows controller to be used in a
broad range of applications
The VAV Series (Variable Air Volume)
Controllers are interoperable, LONMARKcompliant devices. When loaded with an
application from the WorkPlace Tech Tool
application library or programmed with the
WorkPlace Tech Tool, they provide a wide range
of control strategies for pressure independent
terminal boxes with, or without, reheat
capabilities. Both models provide an integral
actuator with manual override and an integral
patented pressure transducer.
LONMARK profile
Fan Coil
Heat Pump
Packaged Rooftop
Satellite
Fan Coil
Heat Pump
Packaged Rooftop
Satellite
Fan Coil
Heat Pump
Packaged Rooftop
Satellite
Inputs/outputs
1 x digital input (DI)
2 x universal inputs (UI)
4 x digital outputs (DO)
3 x universal inputs (UI)
2 x digital outputs (DO)
2 x analogue outputs (AO)
2
3
6
2
x
x
x
x
digital inputs (DI)
universal inputs (UI)
digital outputs (DO)
analogue outputs (AO)
INSTALLATION DETAILS (cont)
Protection class - IP 20
Mounting - 35mm DIN rail or panel
Sensor inputs - MN Sx digital sensor link
Digital inputs (MN 100 & 200 only) - Input type: Dry contact
Universal inputs - 10kΩ thermistor, voltage, current, digital input
Digital outputs - Current ratings: 24VA @ 24Vac, pilot duty
Analogue outputs (MN 150 & 200 only) - Current: 0...20mA. (Output load
80...550Ω.)
INSTALLATION DETAILS
Power supply - 20.4...30Vac, 50/60Hz
Consumption - 15VA @ 24Vac, 50/60Hz, excluding relay
output power
Surge immunity compliance - ANSI C62.41 (IEEE-587,
Category A & B)
ACCESSORIES
LIB-4-485 RS 232/RS 485 converter to connect laptop to NCP network.
PCM20H-485 PCMCIA Card to connect laptop PCs to ARCNET network
(available from www.ccontrols.co.uk).
Note: only suitable for use with Windows XP.
WPA-LON-2 PC (PCMCIA) Card to connect laptop PCs to LONWORKS FTT-10 network.
MN VAV
ARK ®
Controller
MNL-5RF2
with Fan Coil Profile
MNL-5RH2 with Heat Pump Profile
MNL-5RR2
with Roof Top Profile
MNL-5RS2
with Satellite Profile
Data Sheet 10.070
MicroNet MN 100, 150 and 200 controllers are
interoperable, LONMARK compliant units. When loaded with
an application from the WorkPlace Tech Tool application
library or programmed with the WorkPlace Tech Tool, these
controllers provide control for packaged rooftops, heat
pumps, fan coils, unit ventilators and similar applications.
Data Sheet 10.220
Alarms can be acknowledged remotely from a GSM or WAPenabled mobile phone or from a Web browser. Message
content can be customised and alarms can be routed
according to alarm priority, type of alarm and time of day.
This range of MicroNet MN 50 Controllers are interoperable,
LONMARK compliant units. When loaded with an application
from the WorkPlace Tech Tool application library or
programmed with the WorkPlace Tech Tool, these controllers
provide control for packaged rooftops, heat pumps, fan
coils, unit ventilators and similar applications.
Type
MN-RAM Remote Alarm Manager, core
MN-RAM-OUT
”
FEATURES
• Download VisiSat applications to single or multiple
controllers and edit their properties
• Uses VisiSat COM objects to communicate to the
controller network
• Utilises the well established reliability and ease of use
of VisiSat
MN 11 & 13
PRODUCT SELECTION
Controllers (LONMARK®)
(cont)
Workplace
Tech Tool
Satchwell MicroNet
ACCESSORIES – see page 28
Controller
MNL-V1RV2 with integral
actuator
MNL-V2RV2 with integral
actuator and
fan and/or
reheat control
Control
Cooling,
none
Cooling,
series fan,
induction,
parallel fan,
time prop,
none
Inputs/outputs
1 x digital input (DI)
1 x universal input (UI)
1 x digital input (DI)
1 x universal input (UI)
3 x digital outputs (DO)
1 x analogue output (AO)
Reheat type
None
Other
None
Staged electric,
Occupancy
floating/proport
satellite
hydronic reheat,
time proportioned,
none
Data Sheet 10.120
FEATURES
• LONMARK compliant, programmable
• Capability to function in stand-alone mode or as
part of a LONWORKS FTT-10 Free Topology
communications network
• Integrated packaging with actuator, pressure
transducer, and controller
• Integral actuator with manual override and travel
limit settings for easy set up and support
• Proportional (P), Proportional Plus Integral (PI), and
Proportional Plus Integral and Derivative (PID) control
for cooling and heating
• Plenum-rated enclosures
• Air balancing using the MicroNet VAV Flow
Balance software
INSTALLATION DETAILS (cont)
Velocity pressure input - Operating range: 0.0...0.622kPa
Control range: 0.0025...0.498kPa
Accuracy: ±5% @ 0.249kPa with Laminar flow @ 25°C and suitable flow station
Protection class - IP 20
Sensor inputs - MN Sx digital sensor link
Actuator output - Torque rating: 6Nm
Stroke: Fully adjustable from 0...90°C
Timing: Approximately 3 minutes at 60Hz (3.6 minutes at 50Hz) for 90° rotation @ 24Vac
Position indication:
Manual override: Pushbutton
Digital (relay) outputs - MNL-V2RV2: SW24H1, 2 & 3 current ratings 24VA each @
24Vac, 50/60Hz
Digital input - Input type: Dry contact
Universal input - 10k thermistor input, voltage, current, digital input
Analogue output - MNL-V2RV2: Current 0...20mA (output load from 80...550Ω).
INSTALLATION DETAILS
Power supply - 20.4...30Vac, 50/60Hz
Consumption - MNL-V1RV2: 12VA max.
MNL-V2RV2: 84VA max. (12Va plus DO loads @ 24VA each)
Surge immunity compliance - IEC 1000-4-5. ANSI C62.41
(IEEE-587, Category A & B)
ACCESSORIES – see below and page 28
3/8” (9.5mm) to 1/2” (12.8mm) shaft adaptor
AM-135
MNA-FLO-1
MicroNet VAV Enclosure for conduit applications
MNL-FLOW-BAL MicroNet Flow Balance Software
27
PRODUCT SELECTION
Controllers (LONMARK®)
MN VAV
Controller only
for MicroNet
LONMARk Controllers
The MicroNet VAV Series (Variable Air Volume)
Controller is an interoperable, LONMARKcompliant device. When loaded with an
application from the WorkPlace Tech Tool
application library or programmed with the
WorkPlace Tech Tool, it provides control
strategies for pressure independent terminal
boxes, with or without reheat capabilities.
Controller
MNL-V3RV2 with fan
and/or
reheat
control
Control
Cooling,
series
induction,
parallel fan
Inputs/outputs
1 x digital input (DI)
1 x universal input (UI)
3 x digital outputs (DO)
1 x analogue output (AO)
2 x triac outputs (TO)
Reheat type
Other
Staged electric,
Occupancy
floating/proportional satellite
hydronic,
time Proportioned
MN 500
INSTALLATION DETAILS (cont)
Velocity pressure input - Operating range: 0.0...2.5” of W.C. (0.0...0.622kPa)
Control range: 0.01...2.00” of W.C. (0.0025...0.498kPa)
Accuracy: ±5% @ 1.00” of W.C. (0.249kPa) with Laminar flow @ 77°F (25°C) and
suitable flow station
Protection class - IP 20
Sensor inputs - MN Sx digital sensor link
Digital outputs - Relay: SW24H1, 2 & 3 current ratings 24VA each @ 24Vac, 50/60Hz
Triac: current ratings 0.75A (18VA) each output at 24Vac. Total of 18VA for both outputs
Typical load: 24Vac synchronous motor with impedance protected windings
Digital input - Input type: Dry contact
Universal input - 10k thermistor input, voltage, current, digital input
Analogue output - Current 0...20mA (output load from 80...550Ω).
Programmable
Bus-du-jour®
controller
ACCESSORIES – and see below
MNA-FLO-1
MicroNet VAV Enclosure for conduit applications
MNL-FLOW-BAL MicroNet Flow Balance Software
Voltage Divider (converts 1...11Vdc signal to 0.45...5Vdc signal) for universal inputs
250Ω Shunt Resistor Kit for 4...20mA universal inputs
Single LON Terminator for Free Topologies
Double LON Terminator for Bus Topologies (two required)
MicroNet Digital Sensors
PC ISA Card (16-bit) to connect PCs to LONWORKS FTT-10 network
PCMCIA Card to connect Laptop PCs to LONWORKS FTT-10 network
PCLTA_20/FT-10 PCI 932-bit) Desktop Interface
WorkPlace Tech Tool
WorkPlace Tech Tool Unlock Codes
Programmable
Bus-du-jour®
Controller
Controllers (Bus-du-jour®)
Programmable
Bus-du-jour®
Controller
MN 440
Programmable
Bus-du-jour®
Controller
The MN 300 controller is designed for unitary control,
boilers and special applications that may require built-in
transformers and relays.
MNN-30-100
Controller
Comms protocol
Inputs/outputs
NCP Controller
NCP as standard
ARCNET with plug-in card
LONWORKS with plug-in card
8 x universal inputs
4 x triac outputs
3 x relay outputs
The controller can function in stand-alone mode or as part
of a networked system using Bus-du-jour communication
options.
Data Sheet 10.101
INSTALLATION DETAILS
Power supply - 24Vac or 230Vac, 50/60Hz
Consumption - 12VA
Protection class - IP 20
Mounting - Wall or 35mm DIN rail
Sensor inputs - MN Sx digital sensor link
Inputs - 8 universal inputs (digital, resistive, 0...10Vdc)
Outputs - 4 triac outputs for switching 24Vac
3 SPDT 230Vac relays (Line Relays)
Current ratings (for triac outputs): 6Va at 230Vac supply, 18VA at 24Vac supply
Power failure reserve - Controller EEPROM preserves memory for 10 years under
normal conditions of use. The software clock will stop during a power failure. However,
if the controller has an RTC card, the time will not be lost.
FEATURES
• LONWORKS FTT-10, ARCNET and NCP communications
options - Bus-du-jour
• Fully programmable using graphical objects
• Three built-in 230Vac relays
• 230Vac or 24Vac power supply combined with
compact size
• Time schedules
• Switched outputs may be configured as stepped
outputs (including plant rotation), actuator outputs
or outputs for lights and fans
• Eight fully programmable inputs - digital, analogue
0...10V, resistive 0...10Ω
ACCESSORIES – see page 29
Controller
Comms protocol
Inputs/outputs
NCP
Programmable
Controller
NCP as standard
ARCNET with plug-in card
LONWORKS with plug-in card
6 x universal inputs
6 x digital outputs
3 x analogue outputs
This controller is designed for rooftop, unit vent, air
handling unit (AHU), and central heating and cooling
applications.
MNN-44-100
The controller can function in stand-alone mode or as part
of a networked system using Bus-du-jour communication
options. An optional Real Time Clock Card can be fitted to
the MN 440 on an NCP network.
Data Sheet 10.102
INSTALLATION DETAILS
Power supply - 24Vac, 50/60Hz
Consumption - 10VA
Protection class - IP 20
Mounting - Wall or 35mm DIN rail
Inputs - 6 universal inputs (digital, resistive, 0...10Vdc)
Outputs - 6 digital outputs (triac) for switching 24Vac
3 analogue outputs (0...10Vdc)
Current ratings for triacs: 18VA at 24Vac.
Also has a 15Vdc power supply output capable of sourcing 25mA
Power failure reserve - Controller EEPROM preserves memory for 10 years under
normal conditions of use. The software clock will stop during a power failure. However,
if the controller has an RTC card, the time will not be lost.
FEATURES
• LONWORKS FTT-10, ARCNET and NCP communications
options - Bus-du-jour concept
• Fully programmable using graphical objects
• Intelligent multi-loop controller - up to 7 PID
control loops
• Time schedules
• Proportional, integral and derivative control actions
• 0...10Vdc for stepped fan control
• Averaging module for analogue inputs
• Six easily configurable inputs - digital, analogue
0...10V, resistive 0...10kΩ
MNN-50-100
The controller can function in stand-alone mode or as part
of a networked system using Bus-du-jour communication
options. An optional Real Time Clock Card (RTC) can be
fitted to the MN 500 on an NCP network. Other options
include a remote mounting Touch Screen Display which
allows the user to view, query and edit controller properties.
An LCD display option is also available to review the
controller parameters locally.
Accessories
for MicroNet
Bus-du-jour
Controllers
Comms protocol
Inputs/outputs
NCP
Programmable
Controller
NCP as standard
ARCNET with plug-in card
LONWORKS with plug-in card
2 x digital inputs
10 x universal inputs
6 x relay outputs
4 x analogue outputs
INSTALLATION DETAILS
Power supply - 24Vac, 50/60Hz
Consumption - 12VA
Protection class - IP 40
Mounting - Wall or 35mm DIN rail
Inputs - 2 digital pulse counting inputs, 10 universal inputs (digital, resistive, 0...10Vdc)
Outputs - 6 digital outputs (Line Relay) 5A resistive at 230Vac
4 analogue outputs (0...10Vdc)
Power failure reserve - Controller EEPROM preserves memory for 10 years under
normal conditions of use. The software clock will stop during a power failure. If the
controller has an RTC card, then the time will not be lost.
ACCESSORIES – and see main section below
MN-DK
Display Wall Mounting Kit
MN-LCD-100 MicroNet LCD Display
MN-LCDP-100 MicroNet LCD Display (for panel mounting)
MN-TK
Trunking Mounting Kit
MNN-COM
NCP Plug-in card
MNN-TS-100
MicroNet Touch NCP Screen Display
MNN-TSP-100 MicroNet Touch NCP Screen Display (for panel mounting)
Controller
Comms protocol
Inputs/outputs
NCP
Programmable
Controller
NCP as standard
ARCNET with plug-in card
LONWORKS with plug-in card
8 x digital inputs
12 x universal inputs
8 x digital outputs
4 x analogue outputs
The MN 620 Controller is designed for rooftop, unit vent,
air handling unit (AHU) and central heating and cooling
applications.
MNN-62-100
The controller can function in stand-alone mode or as part
of a networked system using Bus-du-jour communication
options. An optional Real Time Clock Card can be fitted to
the MN 620 on an NCP network. Other options include a
touch screen and an LCD display.
Data Sheet 10.104
INSTALLATION DETAILS
Power supply - 24Vac, 50/60Hz
Consumption - 15VA
Protection class - IP 40
Mounting - Wall or 35mm DIN rail
Inputs - 8 digital inputs, 12 universal inputs (digital, resistive, 0...10Vdc)
Outputs - 8 digital outputs (triac). Current ratings 1A at 24Vac (24VA).
4 analogue outputs (0...10V)
Power failure reserve - Controller EEPROM preserves memory for 10 years under
normal conditions of use. The software clock will stop during a power failure. If the
controller has an RTC card, then the time will not be lost.
FEATURES
• LONWORKS FTT-10, ARCNET and NCP
communications options
• Fully programmable using graphical objects
• Intelligent multi-loop controller - up to 8 PID
control loops
• Optimisation module
• Time schedules for plant and controller switching
• Proportional, integral and derivative control actions
can be individually set using controller objects
• Twelve easily configurable inputs, 8 digital inputs
• Eight triac outputs, four 0...10Vdc outputs
ECH-74401
LIB-4-485
LON-TERM1
LON-TERM2
MN Sx
MNA-C
MNA-R10
MNL-C
MNN-MI-100
MNN-RTC
MN-VSCORE
MN-VSLON
WPA-LON-1
WPA-LON-2
ACCESSORIES – see main section below
MN-DK
Display Wall Mounting Kit
MN-LCD-100 MicroNet LCD Display
MN-LCDP-100 MicroNet LCD Display (for panel mounting)
MN-TK
Trunking Mounting Kit
MNN-COM
NCP Plug-in Card required for installation in MN 500 or MN 620, when
connecting controller to NCP network
MNN-TS-100
MicroNet Touch Screen Display
MNN-TSP-100 MicroNet Touch Screen Display (for panel mounting)
PCLTA-20/FT-10 PCI (32-bit) Desktop Interface
RS 232/RS 485 Converter to connect PC to NCP network
Single LON Terminator for Free Topologies
Double LON Terminator for Bus Topologies (two required)
MicroNet Sensors
ARCNET Plug-in Card
ARCNET Router
LONWORKS Plug-in Card
MicroNet Manager Interface
Real Time Clock Card
VisiSat Configuration Tool (requires Visio 2000 software), core software (NCP & ARCNET)
VisiSat LON plug-in (requires MN-VSCORE), required for Bus-du-jour LON devices
PC ISA card (16-bit) to connect PCs to LONWORKS FTT-10 network
PC (PCMCIA) card to connect Laptop PCs to LONWORKS FTT-10 network
ACCESSORIES – see page 29
28
Controller
Data Sheet 10.103
FEATURES
• LONWORKS FTT-10, ARCNET and NCP
communications options
• Fully programmable using graphical objects
• Intelligent multi-loop controller - up to 8 PID
control loops
• Optimisation module and time schedules
• Proportional, integral and derivative control actions
• Ten fully configurable inputs - digital, analogue
0...10V, resistive 0...10kΩ
• Six built-in line voltage relays, 230Vac 5A resistive
• Optional LCD Display for interrogation of local
parameters
MN 620
MN 300
PRODUCT SELECTION
The MN 500 controller is designed for district heating, boiler
plant, air handling unit (AHU), and zone heating and cooling
applications.
Data Sheet 10.121
FEATURES
• LONMARK compliant, programmable
• Proportional (P), Proportional Plus Integral (PI), and
Proportional Plus Integral and Derivative (PID) control
for cooling and heating
• Plenum-rated enclosure
• Air balancing using the MicroNet VAV Flow
Balance software
• Directly compatible with terminal boxes which contain
a synchronous-motor-driven damper actuator
AD-8961-220
AD-8969-202
LON-TERM1
LON-TERM2
MN Sx
WPA-LON-1
WPA-LON-2
ECH-74401
WP-TECH-CD-E-32
WP-TECH-32
Satchwell MicroNet
Controllers (Bus-du-jour®)
(cont)
INSTALLATION DETAILS
Power supply - 20.4...30Vac, 50/60Hz
Consumption - 102VA max: 12VA plus DO loads (24VA
each) and triac load (total 18VA)
Surge immunity compliance - IEC 1000-4-5. ANSI C62.41
(IEEE-587, Category A & B)
Accessories
Satchwell MicroNet
29
PRODUCT SELECTION
Satchwell MicroNet
Digital Modules
Fan Coil Unit Solutions
The Digital Output Module is designed for use with
Satchwell controllers having one or more 0...10Vdc outputs.
The module allows the 0...10Vdc output(s) to drive voltage
free single pole Changeover (SPCO) contacts that are mains
rated. Each module has four relay output channels.
579-1-360
Control
Input
Output
4-channel
0...10Vdc
250Vac
3A resistive, 1A inductive
Data Sheet 2.191
Associated controllers: IAC, MMC, CZT, KMC
Fan Coil Control
Loop
Fan Coil Unit Solutions
Air side control (4-pipe)
Actuator slaving
Sensor slaving
URC-51N-103
BRC-41N-100
BRC-41N-101
BRC-51N-100
BRC-51N-101
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
On board transformer
On board relays
✓
✓
✓
✓
1
1
1
1
Output for electric heater
DX cooling
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Fan on/off
Fan 3-speed control
DRT
DU
DUS
S1
(S-Link)
S2
”
S3
”
S4
”
S4-FCS ”
✓
Duct sensors
DDU
DDT
Actuator/valves
AVU
AVX
BFB (Bonsai)
✓
✓
✓
✓
Room sensors
See page
37
✓
✓
✓
MNL-13RF2
URC-51N-102
✓
✓
MNL-11RF2
URC-51N-101
✓
✓
BRC-51N-501
URC-51N-100
✓
✓
BRC-51N-500
URC-41N-103
✓
✓
✓
✓
BRC-41N-501
URC-41N-102
✓
✓
BRC-41N-500
URC-41N-101
2-pipe
2-pipe auto changeover
4-pipe
✓
✓
✓
✓
✓
✓
URC-41N-100
Controllers
CZU 4201
Networkable
Standalone
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
3
3
3
3
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
31
✓
✓
✓
✓
✓
✓
✓
✓
1
3
1
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
3
1
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
1
3
✓
31
✓
3
1
3
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Controllers
Type
Bonsai Pro
230Vac
BRC-41N-10X with on/off fan control (networkable)
BRC-51N-10X with 3-speed fan control (networkable)
Bonsai Lite
24Vac
BRC-41N-50X with on/off fan control (stand-alone)
BRC-51N-50X with 3-speed fan control (stand-alone)
Where X denotes the pre-loaded application
(possible to change on the field)
0 = 4-pipe FCU, 1 = 2-pipe with changeover
URC-IR-100
Infra-red/RS 232 receiver
URC-SET-100 NCP Palm/Expert commissioning software
UniFact® Pro
Terminal Unit
Controllers
x
x
x
x
x
x
DI
DI – temperature
AI – setpoint
DO – triacs (-41N- only)
DO – relays (-51N- only)
Bonsai outputs
Data Sheet 4.102 & 4.103
INSTALLATION DETAILS
Control range - 0...40°C
Control algorithm - Proportional + integral (time adjustable), or proportional only
Power supply - 230Vac (+10%...–6%) Bonsai Pro, 24Vac (+10%...–6%) Bonsai Lite
Power failure reserve - E2PROM preserves configuration data and user settings
Triac for heater battery - 24Vac output, 2.4VA max
Relay outputs - 230Vac, 5A resistive
Network interface - RS 485 to Sigma or MicroNet network (-10X only)
Sensor types - DU 4301, DUS 4302 or DDU 0001 (return air), MN-S1, S2, S3, S4
Controller protection class - IP 10
Mounting - Wall mounting or DIN rail mounting
ACCESSORIES
BCA 1601 – Controller enclosure for field mounting
BCA 1602 – Controller set-point adjustment module (±3°C)
BCA 9202 – Spare fuses (packet of 5)
VALVE/ACTUATORS
BFB 1500
BFB 1501
BFB 1506
BFB 1510
BFB 1516
BFB 1520
BFB 1525
Data Sheet 4.102
Size/Kvs
15mm –
15mm –
15mm –
15mm –
15mm –
15mm –
15mm –
1.6, 2.0, 2.5 Kvs *
0.6, 1.0 Kvs *
0.6 Kvs
1.0 Kvs
1.6 Kvs
2.0 Kvs
2.5 Kvs
Loop compatible with:
Bonsai BRC Controller
Kvs = Flow in m3 to produce a 1 bar pressure drop when the valve is fully open.
* Kvs is determined by a selectable Kv clip.
INSTALLATION DETAILS
Protection class - IP 52
Control medium - water or glycol solution in water (25% max, freeze protection)
Temperature Limits - 2...95°C
Bypass Kvs - 70% of rated Kvs
International Pressure Rating - PN 10
Type of Operation - Rotary
Actuator Protection Class - IP 52
Cable - 3 core fly lead with controller connection, length 1.5m
Manual Override - By rotary movement of valve arm
Position Indication - Reference moving part to actuator body
ACCESSORIES
BSA 1501 – 1m extension lead (one per actuator)
URC-41N-10X
URC-51N-10X
Controller type
with on/off fan control and S-link support
with 3-speed fan control and S-link support
Where X denotes the pre-loaded application
(possible to change on the field)
0 = 4-pipe FCU, 1 = 2-pipe with changeover,
2 = DX cooling and electric heater, 3 = airside control
URC-IR-100
Infra-red/RS 232 Receiver
URC-SET-100
NCP Palm Commissioning Software
The controller has three main modes: comfort (day), night
(off) and economy. The controller can be switched into any
of these three modes from the MicroNet View PC (if used).
When used stand-alone, the controller can be switched
between two modes: either comfort and economy, or
comfort and night, as selected during commissioning.
A voltage-free input (a timer switch, digital room sensor
or PIR) can be used to switch between the two modes.
A second voltage-free digital input is available for
connection to a thermostat for automatic changeover
between cooling and heating modes for 2-pipe fan coil unit
(FCU) applications.
Inputs/outputs
2 x DI
1 x RI – temperature
1 x AI – setpoint
4 x DO – triacs
3 x DO – relays
Data Sheet 10.130
INSTALLATION DETAILS
Control range - 0...40°C
Power supply - 230Vac (+10%...–6%)
Power failure reserve - E2PROM preserves configuration data and user settings
Sensor types - DU 4301, DUS 4302, S1, S2, S3, S4 (room) or DDU 0001 (return air)
Protection class - IP 20
Mounting - Wall mounting or DIN rail mounting
FEATURES
• Fully networkable or stand-alone controllers
• Selectable control applications (fan-coil applications)
• Low installation cost
• Simple setup using PDA hand-held computer or PC via
infra-red or RS 232 link
• Designed to maximise energy savings
• Optional networking to an MicroNet system
30
2
1
1
1
3
2
Valves
• Patented Fluid Control Methodology
• 3 main valve parts ensures reliable operation
• Ultra low torque valve requirement/Low to silent
operation
• High speed of response
• Dramatically reduces the chances of valve blockage
• No user maintenance required
• 'Tool free' manual override
• Position indication
• Variable Kv allows large range of applications
• Modified equal percentage characteristic
• 1.5m fly lead
• IP 52 (actuator)
• Market leading technology
• Accurate performance across full ambient
temperature range
• Coil balancing bypass as standard
• High differential pressure
• Simple installation and commissioning
The UNIFACTPRO Terminal Unit Controllers have been
designed to meet virtually any fan-coil heating/cooling
applications. The controllers can be used as stand-alone
devices or can be networked to MicroNet systems.
26
Inputs/outputs
FEATURES
Controllers
• Fully networkable or stand-alone controllers
• Easy upgrade of old systems
• High resolution control
• Simple connection to controller
• Controller tests and simulates operation to reduce
commissioning times
• Controller has built in maintenance cycles
• Automated installation and commissioning
• Selectable control applications (fan-coil applications)
• Low installation cost
• Simple setup using PDA hand-held computer or PC via
infra-red or RS 232 link
• Designed to maximise energy savings
• Optional networking to an MicroNet system
✓
✓
(cont)
Select from a choice of controllers, valves and sensors to
build your control loop. The control loop can be
programmed locally and can be connected to Sigma or
MicroNet if required (Bonsai Pro only). Alternatively it can
be left to function stand-alone (Bonsai Lite). The controller
meets the latest CEN application requirements and offers
low cost engineering without maintenance. The patented
valve design ensures long trouble free life
Bonsai Pro &
Bonsai Lite
Function/associated products
PRODUCT SELECTION
Bonsai is a revolutionary new Fan Coil Control Loop that
offers incredible performance and features. The loop is
configurable to suit your applications by offering the latest
technology and variable options.
INSTALLATION DETAILS
Power supply - 24Vac (±10%) 50Hz (–10%) to 60Hz (+10%)
Consumption - 4VA max at 24Vac 50Hz
Protection class - IP20
Indication - LED indication of channel status
Overrides - 1 switch per channel giving ‘HAND’, ‘OFF’ and ‘AUTO’ positions
FEATURES
• Enables controller 0...10Vdc outputs to be used to
switch mains relay contacts
• LED indication of module output status
• ‘HAND’ /‘OFF’ /‘AUTO’ override switch for
each channel
579-1-360
Satchwell MicroNet
31
PRODUCT SELECTION
Satchwell MicroNet
Interfaces
®
Bus-du-jour
Manager Interface
MNA-R10
ARCNET Router
MNN-MI-100
MN-MI features two RS 232 ports that can be connected to
a PC running VisiSat Configuration Tool or MicroNet View
graphical user interface. One of the ports can be connected
to a modem/Ethernet device server on a remote site to
provide WAN connectivity. MN-MI can be configured to
monitor alarm conditions and collect data logs.
Touch Screen
Display
LCD Display
Number of devices
20 x 61 max (per network)
31 x 94 max (per network
INSTALLATION DETAILS
Mounting - Panel or DIN rail
Power supply - 24Vac
Protection class - IP 40
This Router provides the means to extend an ARCNET
network of MicroNet controllers and displays.
MNA-R10
Up to 31 ARCNET sub-nets can sit on the back-bone. Routers
can also provide opto-isolation between sub-nets.
Data Sheet 10.215
FEATURES
• Expands number of network devices
• Extends network length
• Parameter transfer between sub nets
• Provides opto-isolation between networks
• Complete with dedicated ARCNET card
Controller
MicroNet
ARCNET Router
MN Sx
Digital Temperature
Sensors
Comms protocol
ARCNET
MNN-TS-100
MNN-TSP-100
MNL-TS-100
MNL-TSP-100
Number of devices
31 x 94 max (per network)
FEATURES
• NCP, ARCNET and LONWORKS Communications options
• Intuitive, graphics-based menu system
• Unique display for any LONWORKS systems
• Built-in RTS and scheduling for LONWORKS networks
Description
NCP Touch Screen Display
NCP Touch Screen Display (panel mounting)
LON Touch Screen Display
LON Touch Screen Display (panel mounting)
Data Sheet 10.050
ACCESSORIES
MN-DK
Display Wall Mounting Kit for Touch Screen, available for MNN-TS-100
MNA-C
ARCNET Plug-in Communications Card, available for MNN-TS-100
& MNN-TSP-100
INSTALLATION DETAILS
Power supply - 24Vac
Consumption - 2.5VA max
Power failure reserve - EEPROM technology – clock backed
up with battery
The MicroNet Sensors MN Sx Series are a family of digital
wall temperature sensors for use with I/A Series MicroNet
Controllers. These sensors feature a Sensor Link (S-LK)
communication protocol which provides a simple two-wire
interface for power and exchange of sensor and subbase
information. Subbase information includes selecting setpoint, fan speed, operating mode, or emergency heat.
Available in six models, MicroNet Sensors provide an integral
analogue-to-digital conversion for elimination of sensor-tocontroller noise effects and wire resistance offset.
FEATURES
• Aesthetically styled, low profile packaging
• Digital zone temperature indication with variable
resolution and unit of measure
• Self-compensating temperature conversions remove
the need for periodic calibration
• Override button allows the user to switch to operation
mode for out of hours occupation
• Displays selected system values such as setpoint,
external air temperature and operating mode
• Enables the alteration of operating modes
INSTALLATION DETAILS
Power supply - 24Vac
No. and type of PC communication ports - 1 RS 232
Power failure reserve - Non-rechargeable Lithium battery supports the unit’s
RAM for up to 350 days
Mounting - Wall or DIN rail
Protection class - IP 40
This LCD Display is a text menu driven LCD display that
allows a user to monitor and configure parameters of an MN
500 or an MN 620 controller. The display is fully
programmable using the VisiSat Configuration Tool. Up to
246 lines of data can be displayed.
MN LCD
Controller
Comms protocol
MicroNet
NCP as standard
NCP Interface ARCNET with plug-in card
Data Sheet 10.210A
The Touch Screen Display is a graphic LCD display that allows
a user to monitor and configure parameters for multiple
controllers on a Native Communications Protocol (NCP) or
an ARCNET communications network.
MN TOUCH
PRODUCT SELECTION
Sensors
The MicroNet Interface (MI) provides network-level
supervision functions for a network of MicroNet controllers
and displays.
MN-MI
Satchwell MicroNet
MicroNet Sensors
Keypad
Display
Sensor only
none
none
MN-S2
Sensor with override
1 button
LED override status
indication
MN-S3
Sensor with setpoint adjustment 2 buttons
and override
LCD and LED override
status indication
MN-S4
Sensor with setpoint, override
and controller mode functions
5 buttons
LCD and LED override
status indication
MN-S4-FCS
Sensor with setpoint, on/off
and fan speed functions
5 buttons
LCD and LED fan
status indication
MN-S5
Sensor with setpoint, override
controller mode functions and
emergency heat key/indication
6 buttons
LCD and LED override
status indication
Data Sheet 10.000
INSTALLATION DETAILS
Power supply - Powered from the controller
Protection class - IP 20
Ambient limits - Operating temperature 0...50°C, humidity 5...95% rh, non-condensing
Adjustable
Sensing
Fan speed
Switch
scale
range
override
function
DU 4301
none
–5...+50°C
–
–
DUS 4302
+/–
–5...+50°C
–
–
DUSF 4351
+/–
–5...+50°C
Auto, off, on
•
DUSF 4352
+/–
–5...+50°C
Auto, off, 1, 2, 3
•
Data Sheet 1.020
Associated controllers: MN 200/440/500/620 (DU & DUS only URC)
These sensors are specifically used for Satchwell controllers.
Models types have light that informs you that the controller
is running. All sensors use the same single gang sized case.
DU, DUS
DUSF
Description
MN-S1
FEATURES
• Small physical size
• Attractive case design and neutral colour fits in with
most room designs
• Extra low voltage on all sensor types including fan
speed control versions
• Simple wiring connections
• Simple commissioning
• Controller running power light on the sensor
INSTALLATION DETAILS
Sensing element - Negative temp. coefficient thermistor
Wiring - Low voltage dc (15Vdc), DU 3 wire, DUS 4 wire, DUSF 7 wire
Power supply - 15Vdc from UniFact controller
ACCESSORY 837-1-203 Guard Kit
Description
MN-LCD-100 LCD Display
MN-LCDP-100 LCD Display (panel mounting)
Data Sheet 10.060
FEATURES
• Clear, high contrast LCD Display
• Intuitive, text based menu system
• Fully programmable with VisiSat Configuration Tool
• Built-in Real Time Clock with battery back-up
ACCESSORIES
MNN-COM NCP Plug-in Card required for installation in MN 500 or MN 620, when
connecting controller to NCP network
MN-DK
Display Wall Mounting Kit for LCD display, available for MN-LCD-100
MNN-50-100 MicroNet MN 500 NCP Controller
MNN-62-100 MicroNet MN 620 NCP Controller
MNA-C
ARCNET Plug-in Card for MNN-50-100 or MNN-62-100
MNL-C
LONWORKS Plug-in Card for MNN-50-100 or MNN-62-100
INSTALLATION DETAILS
Power supply - 24Vac
Consumption - 2.5VA max
15 Volt dc output - 30 mA max
Power failure reserve - EEPROM technology – clock
backed up with battery
MicroNet System components can only be
installed and commissioned by qualified
MicroNet Partner engineers.
32
33
PRODUCT SELECTION
Drayton Range
Controllers
Networkable
Range
DC1100
No
–20...+120°C
Inputs
DC1100C
Yes
* for replacement
purposes only
A separate channel is provided for the control of hot water.
Data Sheet 2.042
Each of the control routines can be used independently or
combined. In effect the unit can be a compensator, an
optimiser or a combined unit.
Associated sensors - A701 (space), A702 (outdoor), A703 (immersion),
A704 (strap-on), A705 (duct)
LEDs provide an immediate visual indication of output status.
INSTALLATION DETAILS
Power supply - 230Vac, 50/60 Hz
Protection class - IP 40
FEATURES
• Controller can be a combined or stand-alone
optimiser or compensator
• One or two boiler control
• Self learning compensator or fully settable
• Self configuring or settable
• Optimum start- and stop-self learning
• Valve and boiler compensated flow
• Hot water timed channel
• Remote input (Auto/Summer/On/Holiday)
• Frost protection – Multi stage
ACCESSORIES
04 03 109 (RSU)
RB1
This Fuel-saving Controller can replace a conventional time
switch on a heating system and provides a variable start
time dependent on the fall of room temperature during the
off period.
Output relay
6 x temperature sensors, 230V, 1A inductive
1 x remote switch unit
(SPNO)
(auto/summer/heating
on/holiday)
It will control one or two boilers, with requirements for
optimum start and with direct or valve compensation.
Self Configuring
Optimiser/
Compensator
SVT
7-day Optimiser
Remote Switch Unit
Interface Relay
FEATURES (cont)
• Day economy
• Pump run on
• Alarms on low temperatures, controller and sensor faults
• Pump and valve exerciser
• Space temperature influence of compensator
A701
A702
A703
A704
A705
In addition to the regular sensors, there are also range
variants and special limit sensors.
Room, Outside,
Immersion, Duct
and Surface
Sensors
The space sensors are mounted in attractive white plastic
housings to complement any decor. All other types are
housed in sturdy diecast units with mounting arrangements
suitable for their duties.
Type
Sensing range
Associated controllers
Room (Iss E)
Outside (Iss E)
Immersion (Iss D)
Surface (strap on) (Iss J)
Duct (Iss F)
0...45°C
0...120°C
0...120°C
0...120°C
0...120°C
DC Range
”
”
”
”
Output relays
Plant, 250V, 2A (1A inductive)
Control, 250V, 2A (1A inductive)
Data Sheet 2.001
It is used to switch on and off central heating systems and
will substantially reduce fuel consumption compared with
fixed time starting. In all but the very coldest weather the
start time is delayed until the latest time consistent with the
amount of heat necessary to regain the required
temperature at occupancy time.
Compatible room sensor: DR 3253 (supplied with controller)
INSTALLATION DETAILS
Power supply - 230V 50/60Hz
Power failure reserve - For clock - 100 hours, 2 hours for a short power interruption
Protection class - IP 41
Compensators
CSC Compensators are designed for use in residential/
commercial radiator systems to control either a three port
mixing valve or a boiler. The controller senses outside
temperature and varies the water flow temperature to the
radiators. As the outside temperature falls, the radiator
temperature is increased.
The wide range of temperature sensors is designed
specifically for use with Theta, and DC controllers and
provides a selection suitable for most HVAC applications.
Version
Analogue clock
Digital clock
SVT 4201
SVT 4251
FEATURES
• Easy installation - only one sensor required (packed
with the controller)
• Programme override switch
• Choice of day control by separate compensator or
built-in on/off day control
• Minimum night ‘inside’ temperature protection
• Analogue and Digital clock versions available
Sensors
A70 –
PRODUCT SELECTION
Optimiser
The DC1100 is a stand-alone Direct Digital Controller, which
has been designed to suit the control needs of the smaller
commercial and larger domestic property.
DC1100
DC1100C*
Satchwell Controllers
CSC
Compensator
Controllers
Data Sheet 1.955
INSTALLATION DETAILS
Sensoring element - Negative temp. coefficient thermistor
Wiring - 2 wire non-polarised low voltage dc
Adjustments - Concealed
Protection class - IP 40 (space), IP 55 other types
CSC 5252
CSC 5352
Control
Mains or 24V output with no clock
Mains or 24V output with clock
Output
Valve or boiler, 24Vac or 230Vac
Valve or boiler, 24vac or 230Vac,
Pump triac, 24Vac, 1A maximum
Data Sheet 2.021
INSTALLATION DETAILS
Power supply - 230Vac (+10%, –6%) 50/60Hz
Power failure reserve - Settings stored in memory, 1 year battery for clock
Protection class - IP 30
Switched inputs - Night Set Back (NSB): Voltage free, make/break contacts.
Normally closed.
Set Up (Boost): Voltage free, make/break contacts. Normally closed.
Outputs - Valve actuator or boiler output relays: 2 x single pole ON/OFF (interlocked)
230Vac, 10A resistive, 6A inductive.
Pump Output: 1 x 24Vac triac, 1A (0V switched). Clock version only.
Output Supply: 2 x 24Vac terminals used to power external devices up to a total of
10VA maximum.
Sensor inputs - ‘T’ type sensors
Sensor types - DRT 3453, 3451 (optional), DWT 0001, DST 0001, DOT 0002
(see table below)
An optional room temperature sensor can be used to trim
the water temperature based on room temperature. The CSC
can average up to four room sensors.
FEATURES
• Easy to install and commission
• Shipped with typical default values
• Operates a three port valve or boiler
• Max. return function for District Heating applications
• Adjustable economy function
• Night Set Back (NSB) and set-up/boost inputs
• Flow high limit feature
• User configurable Day/Night plant operation
• Room influence mode selection
• Cost effective upgrade of all obsolete Climatronic
controllers
Relay & Switching Units
Drayton relay units will operate over a wide range of
ambient temperatures and are especially suited to heating
and ventilating installations where they might be mounted in
close proximity to boilers and other heat emitters.
No. of switches
Contact rating
Suitable for:
RB1
2 x DPCO
230V, 6A resistive
General purpose
RB2
3 x DPCO
230V, 6A resistive
Valve/actuator
Main Plant Controllers
The CXR Controller is used to control room temperature by
resetting the supply duct air temperature. The room sensor
resets the duct supply temperature to achieve the desired
room temperature. The room temperature can be sensed in
the room or extract duct. The supply duct loop has a purely
proportional control action with the room reset being a
proportional plus integral control action.
Data Sheet 21.685
RB1, RB2
FEATURES
• Enclosed and easy to mount
• Hassle free (time saving)
• Simple design
INSTALLATION DETAILS
Power supply - 230V ac, 45/60 Hz
Ambient limits - –18...66°C
Relay Units
CXR
AHU Room Reset
Controller
This mode switch gives an easy means of overriding the
DC1100 controller. The remote switch has four settings –
Auto, Summer, Heating On and Holiday.
04 03 109
Data Sheet 2.043
FEATURES
• User friendly
• Clearly labelled
• Positive feel switch reduces ambiguity of position
04 03 109
(RSU)
Remote Switch
Unit
For use with DC 1100 controllers only
CXR 5805
Control
Single, two or three stage
Output
24V actuator control
Data Sheet 2.110
INSTALLATION DETAILS
Power supply - 230Vac (+10%, –6%) 50/60Hz
Power failure reserve - settings stored in memory, 1 year battery for clock
Protection class - IP 30
Switched inputs - Night Set Back (NSB): Voltage free, make/break contacts.
Normally closed.
Set Up: Voltage free, make/break contacts. Normally closed.
Remote Low Limit (Summer): Voltage free, make/break contacts. Normally closed.
Night Sensor Selection: Voltage free, make/break contacts. Normally closed.
Outputs - Valve Actuator Output Triacs: 2 x 24Vac triacs, 1A (0V switched and
software interlocked).
Output Supply: 2 x 24Vac terminals used to power the actuator up to a total of
10VA maximum.
Sensor inputs - ‘T’ type sensors
Sensor types - DRT 3651, 3453, DDT 0001, DWT 0001, DST 0001, RPW 4425 (see table
below)
FEATURES
• Easy to install and commission
• Shipped with typical default values
• Quick set mode allows basic settings to be easily
checked and set
• Simple override switch
• Night Set Back (NSB), set-up, summer and night
sensor selection switched inputs
• Optional Scandinavian night sensor
• Up to 4 room sensors can be used for average room
temperature
• Remote setting input for room set value (RPW)
• Cost effective upgrade of all obsolete Climatronic
controllers
SENSORS AND REMOTE SETTING UNIT
DRT 3651, 3453, 3451
DDT 0001
DWT 0001
DST 0001
DOT 0002
RPW 4425
34
35
Type
Room
Duct
Water
Water (strap on)
Outside
Remote Set Value
Range
–5...+40°C
–5...+100°C
–10...+120°C
5...120°C
–40...+55°C
5...50°C
PRODUCT SELECTION
Satchwell Controllers
Main Plant Controllers
PID Pulse 24V
Controller
CZT
PID 0-10Vdc
Controller
Control
Single or two stage
CXT 5605
Output
24V actuator control
This PID Controller can be used to control humidity or
temperature in various ventilation and air conditioning
system applications.
Data Sheet 2.101
INSTALLATION DETAILS
Power supply - 230Vac (+10%, –6%) 50/60Hz
Power failure reserve - Settings stored in memory, 1 year battery for clock
Protection class - IP 30
Switched inputs - Night Set Back (NSB): Voltage free, make/break contacts.
Normally closed.
Set Up: Voltage free, make/break contacts. Normally closed.
Outputs - Valve Actuator Output Triacs: 2 x 24Vac triacs, 1A (0V switched and software
interlocked).
Output Supply: 2 x 24Vac terminals used to power the actuator up to a total of
10VA maximum.
Sensor inputs - ‘T’ type sensors
Sensor types - DDT 0001, DWT 0001, DST 0001, RPW 4425 (see table on previous page)
FEATURES
• Easy to install and commission
• Shipped with typical default values for the
parameters, decreasing commissioning time
• Quick set mode allows basic settings to be easily
checked and set
• Simple override switch
• Operates single or two stage systems
• Night Set Back (NSB) and set-up inputs
• Supports new or old generation Satchwell sensors
• Remote setting input for room set value (RPW)
• Cost effective upgrade of all obsolete Climatronic
controllers
The CZT Controller is designed for use in systems such as
room or return water control. the CZT can be used for single
or two stage control. the CZT is suitable for use with 0 to
10Vdc actuators and/or step controllers.
CZT 5305
Control
Single or two stage
FEATURES
• Easy to install and commission
• Shipped with typical default values for the
parameters, decreasing commissioning time
• Quick set mode allows basic settings to be easily
checked and set
• Simple override switch
• Operates single or two stage systems
• Standard 0...10Vdc output
• Night Set Back (NSB) and set-up inputs
• Existing CZT sensors can be used
• Remote setting input for room set value (RPW)
• Cost effective upgrade of all obsolete Climatronic
controllers
INSTALLATION DETAILS
Power supply - 230Vac (+10%, –6%) 50/60Hz
Power failure reserve - Settings stored in memory, 1 year battery for clock
Protection class - IP 30
Switched inputs - Night Set Back (NSB): Voltage free, make/break contacts.
Normally closed.
Set Up: Voltage free, make/break contacts. Normally closed.
Outputs - Control outputs: 2 x 0...10Vdc outputs for heating and cooling.
Output Supply: 2 x 24Vac terminals used to power the actuator(s) up to a total of
10VA maximum.
Sensor inputs - ‘T’ type sensors.
Sensor types - DRT 3651, 3453, 3451, DDT 0001, DWT 0001, DST 0001, RPW 4425
(see table on previous page)
MMC 4701
Universal Air
Handling Unit
Controller
Output
0...10Vdc for heating and cooling
Data Sheet 2.105
MMC 4601
Multi-loop District
Heating Controller
The FLS is a Step Control Function Module which is
designed to be used in conjunction with
0 to 10Vdc output Controllers thus providing a stepped
on/off output from one or more stages.
C/O Step Control
Function Module
Relays Voltage Free ContactsPower Supply
6 230Vac, 2A (IA inductive) 24Vac
Control
PID
Range
–40…+150°C
0…100% rh
Output
3 x 0...10Vdc
2 x 24V digital
Power Supply
24vac
Data Sheet 2.701
FEATURES
• Serial link
• Can be programmed through its own keyboard
• Low voltage (24Vac)
• Proportional + Integral + Derivative control action for stable control
without offset
• Eleven applications to deal with most humidity and temperature
control schemes
• Built-in real time clock and time schedule
The controller can be configured to run in one of the
applications by simply selecting that application number.
1. Single Stage Temperature Controller
2. Two Stage Temperature Controller
3. Three Stage Temperature Controller
4. Three Stage Room Temperature Reset Controller with
Heat Recovery
5. Three Stage Cascade Temperature Controller
6. Single Stage Temperature Controller
(24Vac Actuator Output)
7. Single Stage Humidity Controller
8. Two Stage Humidity Controller
9. Simple Single Stage Temperature Controller
10. Simple Two Stage Temperature Controller
11. Simple Three Stage Temperature Controller
INSTALLATION DETAILS
Power failure reserve - Settings stored in memory for 1 year, 5 year battery
Inputs - Sensors: DRT, DDT, DOT, DRH, DDH, DOW, DOS, DWT
Outputs - Actuators: ALi, ALE, ALES, AVUE
24Vac switched outputs: 2 x digital outputs, ALX, ALXS, ARX
Protection class - IP 40 when flush mounted
Control
Multi-loop
The MMC is a Multi-loop Controller for use in district
heating schemes.
MMC 4601
The controller incorporates three separate control loops, two
compensated and the other a constant temperature loop.
Data Sheet 2.751
Up to 3 specific points are programmed for the
compensation graph. The MMC automatically joins up these
points to produce a user defined compensation curve. This
adjusts and calculates the required set value of the supply
temperature to the compensated system to match the
prevailing requirements.
Range
–40…+150°C
Output
2 x 0...10Vdc
2 x 24V digital
Power Supply
24Vac
FEATURES (cont)
• Fast response time ensures suitability for tap water control
• Compensation curve can have up to three programmable points giving the
curve two calculated ratios
• Supply high limit
• Built-in ‘default programme’ of typical settings for every parameter operates
on initial start-up
• 0...10Vdc control outputs
• PID programmable control loops
• Periodic pump cycling
• Frost protection logic
INSTALLATION DETAILS
Power failure reserve - Settings stored in memory for 1 year, 5 year battery
Inputs - Global sensors
Outputs - Actuators: ALi, ALE, ALES, AVUE
24Vac switched outputs: 2 x digital outputs
Protection class - IP 40 when flush mounted
Associated input devices - IAC, MMC, CZT, KMC
INSTALLATION DETAILS
Running time though 0...10V stroke - 180 seconds (adjustable 60 to 720 seconds)
Protection class - IP 40 when flush mounted
Terminal Unit
ACCESSORY 866-1-405 Panel Mounting Kit
KMC 3201
Control
Range
PID
–40…+150°C
3-stage temp.
0…100% rh
2-stage humidity
Output
0...10Vdc
for heating
or cooling
FEATURES (cont)
• Low voltage (24Vac)
• Proportional + Integral + Derivative control action for stable control
without offset
• Default programme of typical settings for each parameter operates on
initial start-up
• Security code prevents unauthorised access to setting parameters
• Five applications to deal with most humidity and temperature control schemes,
see the previous section for details of each scheme
• The KMC can be used in place of the Satchwell KZT, KZH and KET controllers
• Real Time Clock (RTC) on the two humidity applications
The KMC control stage outputs are all 0...10Vdc, except the
single stage humidity application that has an optional 24Vac
pulsed output.
The controller can be configured to run in one of the
applications by simply selecting that application number.
1. Single Stage Humidity Controller
2. Two Stage Humidity Controller
3. Single Stage Temperature Controller
4. Two Stage Temperature Controller
5. Three Stage Temperature Controller
The CZU is an Electronic Modulating Controller for the
control of terminal units or fan coils in air conditioning
systems serving small zones of buildings such as individual
offices and hotel bedrooms.
Power Supply
24Vac
Data Sheet 2.120
The KMC is designed to carry out the general control
functions of the Satchwell KZT, KZH and KET controllers with
the added benefit of a digital display.
Multiple
Application PID
Controller
The serial link function allows the MMC to be fully
integrated into a networking system with all the advantages
of remote monitoring, alarms, logging, graphics and remote
setting of all control parameters. The MMC can work as a
fully stand-alone controller.
FEATURES
• Serial link
• Can be programmed through its own keyboard
• Real Time Clock (RTC)
• Self tuning for each control loop, maximises efficiency
for each loop
Data Sheet 2.195
FEATURES
• Six steps available
• Indication LEDs show status of each relay step
• Provides step control of electric heaters and alike
• Panel mounting optional
The KMC Controller can be used to control humidity or
temperature in ventilation and air conditioning systems. The
KMC uses Satchwell sensors to monitor humidity or
temperature and control the plant.
KMC
Control Input
0...10Vdc
FLS 1502
MMC 4701
The MMC has a self tuning function that allows each of the
3 control loops to have its proportional band, integral action
and derivative action values automatically tuned. Self tuning
can be carried out from the MMC keyboard or from
optional external momentary switches connected to it. Self
tuning maximises the efficiency of control loop operation.
Keyboard
FLS
PRODUCT SELECTION
Keyboard
The CXT Controller is primarily designed to control systems
with short time constants and fast response times. This
would typically be the control of heat exchangers, non
storage calorifiers or ventilation plant where the sensor is
placed directly in the controlled medium. The CXT operates
24Vac actuators on two or three port valves. It is capable of
operating single or two stage systems.
CXT
Satchwell Controllers
CZU 4201
Fan Coil Unit
Controller
36
Output
24V actuator control
INSTALLATION DETAILS
Power supply - 24Vac (±10%) 50/60Hz
Protection class - IP 20
Override inputs - TSM 1501: Pipe surface thermostat
Adjustments - Set Value: 10…40°C, Proportion Band: 0…3°K per stage
Dead Zone: 0…6°K, Actuator Stroke Setting: 12.5…75mm
Sensor inputs
Type
Range
DRT 3451, 3453, 3801, 3851
Room
–5...+40°C
DDT 0001
Duct
–5...+100°C
DDU 0001, 1803
Duct
–5...+40°C
FEATURES
• Simple installation
• Three wire connection to actuators
• Optional auto changeover
• Minimal commissioning time
INSTALLATION DETAILS
Power failure reserve - Settings stored in memory, 5 year battery for clock
Inputs - Sensors: DRT, DDT, DOT, DRH, DDH
Outputs - Actuators: ALi, ALE, ALES, AVUE
24Vac switched outputs: 2 x digital outputs, ALX, ALXS, ARX
Protection class - IP 40 when flush mounted
FEATURES
• Direct digital control
• Programmed via the keyboard and display
• Digital display provides comprehensive indications of
all current parameter values, settings and
measurements
Range
10...40°C
Data Sheet 2.201
The range includes temperature sensors and actuators
for valve operation and associated two, three and four
port valves.
CZU
Control
2-stage heating and
cooling with dead zone
37
PRODUCT SELECTION
Satchwell Controllers
Networking
Intelligent/Programmable
The Modem Interface Unit provides the necessary link
between a modem and Satchwell Networking controllers on
a remote site, when using Satchnet Pro Networking
Software. An RS232 input is provided for connection to a
modem on a Wide Area Network (WAN). The MIU is then
able to be connected (via its RS422/485 link) to upto 31
Networking controllers.
MIU
Modem Interface
Unit
Satchwell Controllers/Sensors
MIU 4252
Comms. ports
Comms. speed
Max. cable
length
1 - RS232
1200, 2400, 4800 or 9600 BPS
15m
2 - RS422/485
1200, 2400, 4800 or 9600 BPS
(opto isolated)
1000m
IAC 600
INSTALLATION DETAILS
Power supply - 24Vac (±15%) 47/63Hz
Protection class - IP 41, IP 00 if the RS232 connected is used
Mounting - DIN rail or surface mounting
Status display - 5 LEDs
Power failure reserve - E2PROM preserves configuration data such as password,
telephone numbers, baud rate (if LK 5 is not used) etc.
Universal MultiLoop Intelligent
Advanced
Controller
ACCESSORY 841-2-201 Real Time Clock Board
IAC 420
Universal MultiLoop Intelligent
Advanced
Controller
Terminals
Fixed
Plug-in
IAC 420 - F
IAC 420 - P
The IAC has pre-sets to control common applications such as
terminal unit control, VAV and zone control. In addition the
controller can be customised to work on other less common
applications.
Data Sheet 2.801
Control
3 loop
Range
–40…+150°C
20…90% rh
250…9750 Ohms
0…10,000 Lux
FEATURES (cont)
• 15Vdc supply output for humidity, pressure and UniFact sensors
• 0...10Vdc or stepped fan control
• Averaging of temperature (resistive) sensors and analogue inputs
• Three off two stage controllers with each stage individually selected as PID,
PI or P only
• Three cascade controllers
• Optional Real Time Clock (RTC) board available
The Satchnet software is used to program and monitor the
IAC controllers.
FEATURES
• Compact size allows mounting in a confined space
such as on a fan coil unit
• Serial link
• IACs configured from a computer using the simple
Bubbleland graphical interface
• Internal software time clock, controller and lighting
time schedules
• Complies with latest European EMC standards
• Switched outputs may be configured as stepped
outputs (including plant rotation), actuator outputs or
outputs for lights and fans
• Six configurable inputs that can be individually
configured as temperature (resistive), analogue
(0...10Vdc) or Digital (Switched) inputs
• 0...10 volt inputs can be used for
humidity/pressure/velocity control or as a reset input
• Resistive inputs can be used for Satchwell “T” type
temperature sensors, RPW remote setting units,
Ohms and Light sensors (NORP-12 Light Dependent
Resistor (LDR)).
The base unit’s 6 control loops are configurable and can be
used, for instance, to control the pre-heater, the main duct
temperature, humidity, and re-heat. One advantage of this
integrated multi-loop controller is that the normal interlocks
set up between discrete controllers on a typical system, are
carried out internally by the controller, thus saving on
external wiring. The IAC unit also has a clock and time
schedules built-in which are used to switch plant control
modules etc. the IAC includes full plant sequence control
and rotation based on plant hours run to control Chillers
and Boilers as required. The controller also includes a
number of preset applications in the software to cater for
typical control schemes.
for IAC 600
Controller
INSTALLATION DETAILS
Power supply - 24Vac (±10%) 47/63Hz
15 Volt dc Output - 25 mA max
Power failure reserve - E2PROM preserves configuration data and user settings.
Inputs: 6 x configurable inputs
Outputs: 3 x 0...10V outputs, 6 x digital (triacs on/off) outputs
Protection class - IP 20
Mounting - DIN rail or surface mounting
Outputs
4 x 0...10Vdc
8 x on/off triac
1 x 15Vdc
FEATURES (cont)
• Six temperature (resistive) sensor inputs
• Six 0...10Vdc inputs for humidity, pressure and velocity
• Eight Voltage free switched inputs for use as alarms, Pulse counting etc
• Proportional, Integral and Derivative control actions can be individually set on
each controller module
• Lighting and chiller/boiler Sequence control
• Internal time clock and time schedules for plant and controller switching
INSTALLATION DETAILS
Power supply - 24Vac (±10%) 50/60Hz
15 volt dc output - 30 mA max
Power failure reserve - Non volatile RAM preserves memory for 10 years under
normal conditions of use.
Inputs - Sensors: Six temperature (resistive). Six 0...10 Volt dc, max input 10 Volts dc
Digital input: Eight voltage free contacts, opto isolated. the inputs can be used for pulse
counting, 0.5Hz max. They can also be used for alarms, overrides etc.
Serial link: EIA standard RS422/485 half duplex opto isolated
Outputs - Actuators: Four 0...10 Volt dc. Eight digital (triac on/off) outputs
Protection class - IP 20
Mounting - DIN rail or surface mounting
This optional Touchscreen gives access to upto 31* IAC base
units on its own sub LAN (including the IAC 600, 400, 420
and 200). The Touchscreen is mounted direct on the IAC
base unit.
Touchscreen
Range
–40…+150°C
20…90% rh
250…9750 Ohms
0…10,000 Lux
Data Sheet 2.951
FEATURES
• Intelligent Multi-loop Controller – up to 6 PID
control loops
• Compensation and optimisation modules
• Configured via Satchsoft Networking
• Standard selectable applications built in to the
controller
Outputs
3 x 0...10Vdc
3 x 24V pulsed
24V switched
1 x 15Vdc
Control
6 x PID loops
IAC 600-B
The Satchnet Bubbleland software is fully graphical. Setting
and amending the IAC configurations involves selecting and
joining the required modules using the mouse.
Intelligent/Programmable
This Intelligent Advanced Controller is designed for use in
small and large buildings such as office blocks, hotels and
schools. The IAC has a stand alone capability, and may be
configured from a central computer over the serial link.
(cont)
The IAC 600 is a Multi-loop Configurable Controller
designed primarily for use in typical multi-loop situations
such as air-conditioning systems and Central Plant
Heating/Cooling Systems.
Data Sheet 2.511
FEATURES
• RS232 and RS422/485 ports
• Autoanswer operation on modem sites
• Optional battery backed up Real Time Clock Board
• Allows a further 32 Networking controllers to be
connected, making a maximum of 63 on a single LAN
PRODUCT SELECTION
Part number & item
IAC-TS
Touchscreen
Data Sheet 2.951
The Touchscreen allows the user to interrogate the IACs by
using the touch sensitive screen and menu system.
Information on the sensor values and outputs can be
displayed and parameters can be altered if required. The
Touchscreen contains a battery backed clock that is used
by the IACs on the sub LAN as a back up to their own
internal clocks.
INSTALLATION DETAILS
Power supply - Powered from the IAC unit
Power failure reserve - Non volatile RAM with built-in Real Time Clock gives 3 year
back up of clock and memory under normal conditions of use.
ACCESSORY DDC 2601 Remote Touchscreen Adaptor Kit
* Dependent on the number of parameters to be displayed.
Each Touchscreen can display upto 256 parameters.
FEATURES
• Mounts on IAC base unit or optional panel mounting
• Touch sensitive graphic LCD screen
• Menu operation for interrogation and setting
• Back-lit screen for easy viewing
• Communicate with up to 31 - IACs
• Battery backed clock provides time synchronisation
ACCESSORY 841-1-201 Real Time Clock Board
Room Temperature, Temperature/humidity & Carbon Dioxide Sensors
Designed for use with Satchwell controllers to
provide temperature control of heating and air
conditioning plant.
DR/DRT
Air Temperature
Sensors
FEATURES
• Aesthetically pleasing case designs
• Small physical size
• Wide temperature sensing range
• Simple wiring connections
• Simple commissioning
INSTALLATION DETAILS
Sensing element - Negative temp. coefficient
thermistor (0...10k ohm)
Wiring - Low voltage dc, DRT - 2, 3 or 4 wire
and DR - 2 wire
Designed for use with controllers to provide
temperature control of heating and air
conditioning plant.
DRT
Room Temperature
Sensors
38
FEATURES
• Aesthetically pleasing case designs
• Small physical size
• Wide temperature sensing range
• Simple wiring connections
• Simple commissioning
DR 3253
DRT 3451
DRT 3453
DRT 3651
DRT 3652
Data sheet
Adjustable scale
(exposed)
none
10...35°C
none
10...35°C
10...35°C + LED
For use with controller or controller actuator types
Sensing CZT CSC LIB MMC CZU KMC IAC SVT
BAS
range
CXR
MN
Sigma
–5...+40°C
–
–
–
–
–
–
–
–
•
–5...+40°C
–
–
–
–
–
• –
• –
–5...+40°C •
• • • • • • –
•
–5...+40°C •
–
–
• – • • –
•
–5...+40°C
–
–
–
–
–
–
–
• –
2.105 2.021 2.041 2.701 2.201 2.120 2.951 2.001
13.341
2.110
2.541 2.751
10.XXX
13.XXX
Data Sheet 1.001
ACCESSORIES
837-1-203 DR/DRT Guard Kit - protects against impact and tampering
837-1-352 DRT +/– Scale Converter – used to convert standard exposed adjustment types. Consists of
just the sensor front cover. Suitable for DRT 3451 and 3651.
For use with controller or controller actuator types
Adjustable scale Sensing CZT CSC LIB MMC CZU KMC IAC SVT
BAS
(exposed)
range
CXR
MN
Sigma
DRT 4453
none
–5...+40°C •
• • • • • • –
•
Data sheet
2.105 2.021 2.041 2.701 2.201 2.120 2.951 2.001
13.341
2.110
2.541 2.751
10.XXX
13.XXX
Data Sheet 1.040
INSTALLATION DETAILS
Sensing element - Negative temp. coefficient thermistor (0...10k ohm)
Wiring - Low voltage dc, DRT - 2, 3 or 4 wire
39
PRODUCT SELECTION
Satchwell Sensors
Room Temperature, Temperature/humidity & Carbon Dioxide Sensors
Sensors incorporate fan speed control switches and are used
with CZU and IAC temperature controllers. This system is
used for the control of temperature zones in buildings, such
as hotel bedrooms or individual offices, which are air
conditioned by fan coil units.
DRT
Temperature
Sensors with Fan
Speed Switches
Satchwell Sensors
Room Temperature, Temperature/humidity & Carbon Dioxide Sensors
(cont)
Adjustable
scale
Sensing
range
No. switch Switch
positions position
DRT 3801
10...35°C
10...35°C
2
0, 1
DRT 3851
10...35°C
10...35°C
4
0, 1, 2, 3
Switch
function
Off, on
Off, on, medium, high
Associated controllers: CZU, IAC
INSTALLATION DETAILS
Sensing element - Negative temp. coefficient thermistor
Wiring - 2 wire low voltage dc, non-polarised to controller
Switch rating - 2.5A 250Vac. Motor full load current. 12A motor starting, 250Vac. Note:
manual switches suitable for choke controlled or capacitor controlled fan motors.
DRCO
Infrared Analyser
CO2 Sensor
(cont)
Measurement Repeatability Operating
range (selectable)
temp.
The DRCO is a non-dispersive infrared analyser designed for
measuring environmental CO2 concentration in indoor living
spaces. Its measurement range of 0...2000 or 0...5000 ppm
covers the range required to monitor compliance with
ASHRAE or other ventilation efficiency standards.
Data Sheet 1.002
FEATURES
• Aesthetically pleasing case designs
• Robust
• Easy to operate
• Simple wiring connections
• Simple commissioning
PRODUCT SELECTION
DRCO 2702
An LCD display is available to provide local indication of CO2
concentration and facilitate the setup and calibration
process. An adjustable setpoint relay is available for direct
control and alarm applications. Microprocessor-based digital
electronics and a unique self-calibration algorithm improves
long-term stability and accuracy.
0...2000 or
0...5000 ppm
±20 ppm
0...50°C
Input
voltage
Analogue output
(selectable)
20...30V
ac/dc
0...5Vdc,
0...10Vdc
or 4...20mA
Data Sheet 1.601
Protection class - IP 20
Accuracy - ±75 ppm
Response time - <60 seconds for 90% step change
Duct Temperature, Temperature/humidity, Carbon Dioxide & Pressure Sensors
Adjustable
Sensing
Fan speed
Switch
scale
range
override
function
DU 4301
none
–5...+50°C
–
–
DUS 4302
+/–
–5...+50°C
–
–
DUSF 4351
+/–
–5...+50°C
Auto, off, on
•
DUSF 4352
+/–
–5...+50°C
Auto, off, 1, 2, 3
•
Data Sheet 1.020
Associated controllers: MN 200/440/500/620 (DU & DUS only URC)
These sensors are specifically used for Satchwell controllers.
Models types have light that informs you that the controller
is running. All sensors use the same single gang sized case.
DU, DUS
DUSF
MicroNet Sensors
FEATURES
• Small physical size
• Attractive case design and neutral colour fits in with
most room designs
• Extra low voltage on all sensor types including fan
speed control versions
• Simple wiring connections
• Simple commissioning
• Controller running power light on the sensor
INSTALLATION DETAILS
Sensing element - Negative temp. coefficient thermistor
Wiring - Low voltage dc (15Vdc), DU 3 wire, DUS 4 wire, DUSF 7 wire
Power supply - 15Vdc from UniFact controller
This sensor’s revolutionary adjustable probe length enables
the user to find the best monitoring position with ease. It is
designed to be used with Satchwell controllers to provide
temperature control in ventilation systems.
DDT 0001
Air Temperature
Sensor
ACCESSORY 837-1-203 Guard Kit
The DRTE Active Sensor gives proportional 0...10Vdc output
for control of rooms or small zones. The sensor will control
actuators such as Satchwell ALi and ARE. Alternately the
output can be used as a low limit on other 10 volt
equipment or as a reset signal to other controllers.
DRTE
Active Temperature
Sensor
DRTE 2201
Data Sheet 1.101
FEATURES
• Tamperproof
• Small physical size
• Reversible output ramp: heating or cooling
• Low cost installation
• Simple commissioning
Active Temperature
Sensors with Fan
Speed Switches
Room Humidity/
Temperature
Sensors
Sensing
range
No.switch
positions
Switch
position
Switch
function
DRTE 2801
10...40°C
10...35°C
DRTE 2851
10...40°C
10...35°C
2
0, 1
Off, on
4
0, 1, 2, 3
Off, on, medium, high
Data Sheet 1.102
INSTALLATION DETAILS
Sensing element - Negative temp. coefficient thermistor
Switch rating - 2.5A 250Vac. Motor full load current. 12A
motor starting, 250Vac. Note: manual switches suitable for
choke controlled or capacitor controlled fan motors.
DRH 7702
Sensing
Accuracy Temp. sensor
Control range
Relative humidity only
±2% rh*
None
0...90% rh
and 0...+50°C
T type
Humidity: 0...90% rh
and 0...+50°C
Temperature 0...+100°C
DRH 7703
Models are available with humidity sensing only or humidity
combined with temperature sensing. Two ranges of resistive
outputs are available across the monitored temperature
range i.e. T type or standard NTC thermistor. 2% and 1%
accuracy versions are available certified for the National
Institute of Standards Technology (NIST).
DRTH 7712
“
±3% rh*
Relative humidity and temp. ±2% rh*
DRTH 7713
“
DRTH 8731
“
Data Sheet 1.502/1.504
±3% rh*
±1% rh** 0...10Vdc
*@10...90% rh
ACCESSORIES
HDS 9201
1% Humidity Element (NIST Certified)
HDS 9202
2% Humidity Element (NIST Certified)
HDS 9102
Replacement Humidity Element (2%)
HDS 9103
Replacement Humidity Element (3%)
DDH 7602
Spring clip
Sensing
Accuracy Temp. sensor
Control range
Relative humidity only
±2% rh*
None
0...90% rh
and 0...+50°C
NTC thermistor
Humidity:
0...90% rh
and 0...+50°C
DDH 7603
“
DDTH 7612
±3% rh*
Relative humidity and temp. ±2% rh*
DDTH 7613
“
±3% rh*
Temperature:
0...+100°C
FEATURES
• 0...10Vdc or 0...5Vdc humidity output
• 24Vac or 12...24Vdc input power
• Humidity sensor element contained in removable
probe tip; replacement element available
• Small physical size
• Simple wiring connections and commissioning
Data Sheet 1.503
*@10...90% rh
ACCESSORIES
HDS 9201
1% Humidity Element (NIST Certified)
HDS 9202
2% Humidity Element (NIST Certified)
HDS 9102
Replacement Humidity Element (2%)
HDS 9103
Replacement Humidity Element (3%)
FEATURES
• Suitable for clean, dry air or any inert gas
• Field selectable output voltages
• Rapid dynamic response
• Short circuit and reverse polarity protection
Mounting
type
LCD
display
DDP 5601
DDP 5610
Duct
”
No
”
24.9/62.2/124.5/249
4...20mA or 0...5/0...10V
±24.9/±62.2/±124.5/±249
”
DDP 6601
DDP 6610
Panel
”
Yes
“
249/622/1245/2490
4...20mA or 0...5/0...10V
±249/±622/±1245/±2490
”
Data Sheet 21.606
Pressure ranges (pa)
(field selectable)
41
Output
(field selectable)
Associated controllers: URC, IAC 420, IAC 600, MN300...620,
BAS, Sigma
INSTALLATION DETAILS
Accuracy - ±1% f.s.
Dynamic response - <5msec
Protection class - IP 65
ACCESSORY
40
5573Ω
INSTALLATION DETAILS
Sensing element - Negative temp. coefficient thermistor
Wiring - 2 wire non-polarised low voltage dc
These sensors are for the control of air pressure in
duct-work by the regulation of variable volume fans and
pressure regulating dampers in distribution systems and
terminal units. They can also be used for monitoring air
filter conditions.
Differential Air
Pressure Sensor
Direct
Associated controllers: CZU, IAC, URC, BRC, MN300...MN620, Sigma
INSTALLATION DETAILS
Power supply - 24Vac or 12...24Vdc for humidity sensors
Humidity sensor - Digitally profiled thin-film capacitive
element
Temperature effect - ±0.03% rh/°C over 0...50°C
Stability - ±1% rh annually at 20°C
Protection class - IP 65
Ambient limits - Operating temperature 0...60°C, humidity
10...90% rh, non-condensing
Compatible controllers - KMC, MMC, IAC, MicroNet, BAS,
Sigma
DDP
Fixing
5573Ω
DDU 1803
Models are available with humidity sensing only or humidity
combined with temperature sensing. Two ranges of resistive
outputs are available across the monitored temperature
range i.e. T type or standard NTC thermistor.
INSTALLATION DETAILS
Power supply - 24Vac or 12...24Vdc for humidity sensors
Humidity sensor - Digitally profiled thin-film capacitive element
Temperature effect - ±0.03% rh/°C over 0...50°C
Stability - ±1% rh annually at 20°C
Protection class - IP 20
Ambient limits - Operating temperature 0...60°C, humidity 10...90% rh, non-condensing
Compatible controllers - KMC, MMC, IAC, MicroNet, BAS, Sigma
FEATURES
• Aesthetically styled, low profile packaging
• 0...10Vdc humidity output
• 24Vac or 12...24Vdc input power
• Humidity or humidity and temperature output
• Removable Humidity sensor element; replacement
elements available
• 1% and 2% versions supplied with NIST certificate
Resistance at 20°C
–5...+40°C
(non adjust.)
“
Data Sheet 1.030
This sensor range is designed for use with controllers to
provide relative humidity measurement and temperature
control in ventilation systems.
**NIST Certified
5573Ω
Sensing range
DDU 0001
Fan Coil Unit Return
Air Temp. Sensors
DDH, DDTH
Resistance at 20°C
INSTALLATION DETAILS
Sensing element - Negative temp. coefficient thermistor
Wiring - 2 wire non-polarised low voltage dc (safety extra low voltage SELV)
Protection class - IP 65
DDU 0001, 1803
Duct Humidity/
Temperature
Sensors
Associated actuators: ALE, ALES, ARE, ARES, AVE, AVUE, ALi
This sensor range is designed for use with controllers to
provide relative humidity measurement and temperature
control in ventilation systems.
DRH, DRTH
Adjustable
scale
Min 100mm,
max 330mm infinitely
variable between limits
Compatible controllers: CSC, CXR, CXT, CZT, CZU, IAC, KMC, MMC, MicroNet,
BAS, Sigma
FEATURES
• Simple fixing (direct or spring clip)
• Compact size
• 1.5m fly lead
Associated controllers: MMC and IAC (reset or low limit)
Associated actuators: ALE, ALES, ARE, ARES, AVE, AVUE, ALi
Stem length
–5...+100°C
Data Sheet 1.003
FEATURES
• Very fast response to temperature changes
• Stylish design has easily removable screw lid
• Simple wiring connections
• Simple commissioning
• Variable probe length (covers many applications)
• Optimum sensing position can be easily set
• Simple replacement of existing sensors
Temperature sensors specifically designed for use in return
air space of terminal units.
Sensing range
0...40°C
INSTALLATION DETAILS
Sensing element - Negative temp. coefficient thermistor
Output - 1 reversible 0...10Vdc signal (heating or cooling), 1 fixed 10Vdc output.
Proportional band - 2...15K
Power supply - 24Vac (+/–10%) 50/60Hz
Protection class - IP 20
Sensors incorporate fan speed control switches. These
devices are used for the control of temperature zones in
buildings, such as hotel bedrooms or individual offices,
which are air conditioned by fan coil units. Can be used with
any 0...10V actuator.
DRTE
Adjustable scale
none
Sensing range
DDT 0001
DDP 3601 Fitting Kit
PRODUCT SELECTION
Satchwell Sensors
Duct Temperature, Temperature/humidity, Carbon Dioxide & Pressure Sensors
DDCO
Infrared Analyser
CO2 Sensor
Measurement Repeatability Operating
range (selectable)
temp.
Input
voltage
Analogue output
(selectable)
20...30V
ac/dc
0...5Vdc,
0...10Vdc
or 4...20mA
The DDCO is a non-dispersive infrared analyser designed for
measuring environmental CO2 concentration in ventilation
systems and indoor living spaces. Its measurement range of
0...2000 or 0...5000 ppm covers the range required to
monitor compliance with ASHRAE or other ventilation
efficiency standards.
DDCO 2602
An LCD display is available to provide local indication of CO2
concentration and facilitate the setup and calibration
process. An adjustable setpoint relay is available for direct
control and alarm applications. Microprocessor-based digital
electronics and a unique self-calibration algorithm improves
long-term stability and accuracy.
Protection class - IP 65
Accuracy - ±75 ppm
Response time - <60 seconds for 90% step change
Sensor connection - 2 plastic tubes with inside diameter of 6mm ??????
±20 ppm
0...50°C
This sensor is for use with Satchwell controllers to provide
relevant temperature influence on the heating and air
conditioning plant, in accordance with prevailing
weather conditions.
Data Sheet 1.601
The DDV gives a 0...5Vdc output over a range of 0.4...10 m/s.
The velocity range may be limited if required to give greater
resolution. On its minimum setting the range is
approximately 0.4 to 4 m/s.
DDV 1201
Output
Measuring range
(adjustable by min/max knob)
0...5Vdc
0.4...10 m/s (max)
0.4...4 m/s (min)
Data Sheet 21.671
Air Velocity Sensor
DOT 0002
DOT 0002
Outside Solar
Sensor
Resistance at 20°C
–40...+55°C
5573Ω
12490Ω
Compatible controllers: CSC, IAC, KMC, MMC, LIB, MicroNet, BAS, Sigma
INSTALLATION DETAILS
Sensing element - Negative temp. coefficient thermistor
Wiring - 2 wire non-polarised low voltage dc (safety extra low voltage SELV)
Protection class - IP 65
The DOS Solar Sensor has particular advantages to combat
the specific effect of solar heat gain. Its application is a true
benefit to modern glass/translucent buildings where solar
gain is a negative influence on comfort and occupant
efficiency. Energy savings will be realised by allowing for
solar contributions.
DOS 0001
Sensing range
Data Sheet 1.402
FEATURES
• Fully backwards compatible
• Small physical size
• Simple commissioning
Outside Temp.
Sensor
Associated controllers: IAC, MicroNet, BAS, Sigma
INSTALLATION DETAILS
Sensing element - Negative temp. coefficient thermistor
Wiring - 3 wire (signal, earth and 24Vac power supply)
Protection class - IP 41
DDV
PRODUCT SELECTION
Outside Sensors
(cont)
0...2000 or
0...5000 ppm
Satchwell Sensors
DOS 0001
Sensing range
Resistance at 20°C
–40...+55°C
5573Ω
Data Sheet 1.402
Compatible controllers: CSC, IAC, KMC, MMC, LIB, MicroNet, BAS, Sigma
FEATURES
• Fully backwards compatible
• Small physical size
• Simple commissioning
INSTALLATION DETAILS
Sensing element - Negative temp. coefficient thermistor
Wiring - 2 wire non-polarised low voltage dc (safety extra low voltage SELV)
Protection class - IP 65
This sensor is used with Satchwell controllers to influence
temperature or time control of heating and air conditioning
plant in accordance with prevailing weather conditions.
DOW 2701
Pipe Temperature Sensors
The DST 0001 permits the monitoring and control of fluid
temperature through its specially designed thermistor
housing. Its simple installation promotes its flexible use for
temporary or permanent monitoring/control applications.
DST 0001
Water Temp.
Sensor (surface)
DST 0001
FEATURES
• Allows direct mounting to pipe surface, allowing any
point to be monitored
• Easily fitted, making it perfect for permanent or
temporary situations
• Simple commissioning
Water Temperature
Sensor
(immersion)
Fast Response
Water Sensor
(immersion)
Resistance at 20°C
Pipe surface
5573Ω
Data Sheet 1.401
INSTALLATION DETAILS
Sensing element - Negative temp. coefficient thermistor
Output signal - 0...10V signal
Power supply - 24Vac
Protection class - IP 47
Sensing range
Stem length
–10...+120°C
Min 100mm,
max 330mm infinitely
variable between limits
Resistance at 20°C
DOW
Wind Sensor
Remote Adjustment Units
5573Ω
The RPW Unit is used for adjusting the controller’s setpoint
from remote site.
INSTALLATION DETAILS
Sensing element - Negative temp. coefficient thermistor
Wiring - 2 wire non-polarised low voltage dc (safety extra low voltage SELV)
Protection class - IP 65
Time constant - 7 secs.
ACCESSORIES
DWA 0001 – Brass Pocket Adaptor
DWA 0002 – Immersion Pocket, 120mm,
DWA 0003 – Immersion Pocket, 200mm,
DWA 0004 – Immersion Pocket, 200mm,
DWA 0005 – Immersion Pocket, 120mm,
DWT 0002
Scale
range
RPW 4425
–5...+50°C
Data Sheet 1.901
These units are used on various Satchwell temperature
controllers to give remote set value adjustment.
Compatible controllers: CSC, CXR, CXT, CZT, IAC, KMC, MMC, LIB, MicroNet,
BAS, Sigma
RPW
Remote Setting
Unit
INSTALLATION DETAILS
Indication - Graduated dial
Adjustment - Dial
Mounting - Suitable for surface or conduit box mounting
Protection class - IP 20
stainless steel
brass
stainless steel
brass
Sensing range
Stem length
Resistance at 20°C
–10...+120°C
120mm
(non adjustable)
5573Ω
Data Sheet 1.204
Compatible controllers: CSC, CXR, CXT, CZT, IAC, KMC, MMC, LIB, MicroNet,
BAS, Sigma
FEATURES
INSTALLATION DETAILS
• Very fast response to temperature change
Sensing element - Negative temp. coefficient thermistor
• Small probe diameter for direct insertion into small pipes
Wiring - 2 wire non-polarised low voltage dc (safety extra low voltage SELV)
• Stainless steel probe
Protection class - IP 65
• Simple commissioning
Time constant - 2 secs
42
Sensing range
–40...+40°C (wind effect zero above 20°C)
Compatible controllers: CSC, CXR, CXT, CZT, IAC, KMC, MMC, LIB, MicroNet,
BAS, Sigma
Data Sheet 1.203
FEATURES
• Variable stem length - 100mm to 330mm
• Sensor crown ensures good thermal contact with
pocket end
• Fast response
• 120mm brass pocket (DWA 0005) and heat conductive
paste supplied as standard
• Simple commissioning
Control function
Wind effect only
Data Sheet 1.203
DWT 0001
The DWT 0002 sensor is designed for use in the most
demanding control schemes. Many modern applications call
for above average performance and this device is key to
stability and efficiency. The sensing element is encased in the
optimum amount of high quality stainless steel, permitting
ultra fast detection of temperature change.
DWT 0002
Mounting
5...120°C
INSTALLATION DETAILS
Sensing element - Negative temp. coefficient thermistor
Wiring - 2 wire non-polarised low voltage dc (safety extra low voltage SELV)
Protection class - IP 65
Fixing strap - Metal, sufficient for pipes up to 100mm
This sensor simplifies product selection and improves control
loop performance with its unique probe assembly. The shaft
is simply extended and inserted into the pocket, ensuring a
good contact. The sensor can be used with a vast range of
other manufacturer’s pockets when used in conjunction with
the pocket adaptor DWA 0001. The use of the adaptor
avoids system drain downs and costly down time.
DWT 0001
Sensing range
43
Controlled
condition
Temperature
CZT
CXR
CXT
•
For use with controller type
MMC KMC
IAC
MN
(300, 440,
500, 620)
•
•
•
•
PRODUCT SELECTION
Satchwell Switches & Thermostats
Duct Temperature Thermostats, Pressure and Air Flow Switches
These thermostats are for duct applications and incorporate
a single pole double throw contact switch.
FEATURES
• Simple installation and commissioning
• Cable gland supplied
Satchwell Switches & Thermostats
Pipe Temperature Thermostat
Sensing range
Adjustment
Stem type
Contact rating
TDR 2201
0...60°C
Exposed
Rigid stem
(190mm x 8mm Ø)
230Vac, 16A
SPDT
TDC 2202
0...60°C
Exposed
Capillary stem
(1 metre)
The TSM Thermostat is typically used in water control
applications where it is not possible to insert a pocket into
the pipe. The thermostat is attached to the pipe by a spring
strap (supplied).
Data Sheet 21.001
TDR, TDC
The SPA 1501…1504 Differential Pressure Switches can be
used to signal when the pressure difference is too high due
to a blocked filter, too low due to flow failure, or for level
control in a pressurised vessel. Suitable for use on a vacuum.
SPA
Universal
Differential and
Universal Pressure
Switches
TSM
Protection class - IP 40
Max head temperature - 80°C
Air Temperature
Thermostats
The SPA 1505 &1506 Pressure Switches can be wired into
control circuits or contactors to provide a high or low
pressure cut-out. Alternatively, they can be wired directly to
a bell or light to provide a high or low pressure alarm. Not
suitable for use on a vacuum.
Spec. no.
Sensing range
Reset differential*
Contact rating
Universal
Differential
Pressure
SPA 1501
150 - 1000 mbar
50 - 100
1A @ 250v
SPA
SPA
SPA
SPA
1502
1503
1504
1505
6 - 20 mbar
15 - 60 mbar
40 - 200 mbar
120 - 2200 mbar
3-8
5 - 16
20 - 60
110 - 450
1A
1A
1A
6A
SPA 1506
1000 - 6000 mbar
200 - 1500
6A @ 250v
250v
250v
250v
250v
TCL
SFA 1451
Adjustment
Contact rating
0...90°C
Exposed
230Vac, 16A
SPDT
Data Sheet 21.003
FEATURES
• Simple installation and commissioning
• Cable gland supplied
Ambient temperature limits - Maximum sensing plate temperature 100°C
Maximum pipe diameter - 150mm
Protection class - IP 40
Outside and Pipe Frost Thermostats
@
@
@
@
Protection class - SPA 1501-1504 IP 65, SPA 1505/1506 IP 54. *Adjustable between (mbar)
Max line pressure - SPA 1501 - 20 bar, SPA 1502-1504 - 10 bar, SPA 1505/1506 - 6 bar
This switch is designed to control air flow using a paddle to
switch on and off the power supply. The paddle can be
trimmed if the air flow is above 5 metres per second.
Sensing range
TSM 2501
Strap-on Pipe
Thermostat
Type
Universal
Pressure
PRODUCT SELECTION
Flow setting
Contact rating
1 m/s, 2.5 m/s (paddle untrimmed)
24...230Vac, 15A
single pole, double throw
The range of TCL Freeze Thermostats covers both outside,
heater battery and water pipe freeze protection.
Sensing range
Type
Stem type
Contact rating
TCL 1601
–15...+10°C
–
The TCL 1601 wall mounting freeze thermostat is suitable for
outside mounting.
Outside
(auto reset)
230Vac SPDT
heating 10A, cooling 3A
TCL 1602
–18...+13°C
Coil and pipe
(manual reset)
Capillary stem
(6m)
230Vac, 6A
SPDT
TCL 1603
–18...+13°C
Coil and pipe
(auto reset)
Capillary stem
(6m)
The TCL 1602 and TCL 1603 have a capillary that will sense
the lowest temperature on the face of the battery or the
surface of a pipe.
Data Sheet 21.004
Air Temperature
Thermostats
INSTALLATION DETAILS
Protection class - TCL 1601: IP 65, TCL 1602/3: IP 43
Data Sheet 21.670
Head protection class - IP 65
SFA
Transducer
Air Flow Switch
The SPA Differential Pressure Switch is used to monitor
non-inflammable and non-aggressive gases. Typical
applications are filter dirty and fan run/stop detection.
ACCESSORY DDP 3601 Fitting Kit (containing 2 metres of
PVC tubing and 2 duct mounting pitot tubes)
Adjustable range
for trip pressure
Max. operating
pressure
Repeatability
Contact
rating
SPA 1401
0.2...3.0 mbar
50 mbar
0.025 mbar
230Vac, 1A
SPDT
SPA 1402
1.0...10.0 mbar
50 mbar
0.05 mbar
EPT
Data Sheet 21.601
SPA
Electro Pneumatic
Transducer
Protection class - IP 54
Pressure connection - 2 plastic tubes with inside diameter of 6mm
Air Differential
Pressure Switch
Pipe Temperature Thermostats and Flow Switches
The SFW Flow Switch is designed to control water flow, in
pipe diameters from 1” to 6”, using a paddle to switch on
and off the power supply. The paddle can be trimmed to
suit the flow required. It is designed to be mounted in a
short necked welded socket or a tee with a short branch.
This transducer is used as an interface between an electronic
controller and a pneumatically operated control valve or
damper. It is set to receive a 0...10Vdc input and converts it
to a proportional 0...20 PSI output signal. The input may be
configured, if required, for 0...5Vdc or 4...20mA by using the
jumpers on the PCB.
Max fluid temp.
Contact rating
85°C
24...230Vac, 15A
single pole, double throw
SFW 1251
EPT 7401
FEATURES
• Smooth stable linear performance
• Choice of input signals to meet most control
applications. 0...10Vdc, 0...5Vdc or 4...20mA selected
from onboard jumpers
• LED indication of supply status and
increasing/decreasing pressure signal
• Indication gauge for actual air pressure output
• Manual override of output pressure signal
Water Flow Switch
Adjustment
0...90°C
Exposed
FEATURES
• Simple installation and commissioning
• Cable gland supplied
Data Sheet 21.001
Pocket
Contact rating
1/2”
NPT
(100mm x 8mm Ø)
230Vac, 16A
SPDT
Protection class - IP 40
Max head temperature - 80°C
TWK
Water Immersion
Thermostat
These thermostats are typically used in water high
limit/control applications such as HWS cylinders or boilers.
The TWL is a manual reset, high limit thermostat with a
Single Pole Double Throw (SPDT) action. The TWM is a
combined control thermostat and manual reset, high limit
thermostat allowing independent setting of both the control
point and high limit temperature.
TWL, TWM
Water Immersion
Thermostats
(manual reset)
Sensing range
Adjustment
TWL 2302
65...85°C
Exposed
Pocket
NPT
(100mm x 8mm Ø)
TWM 2401
0...90°C (control)
70...90°C (limit)
Exposed
Concealed
1/2” NPT
(100mm x 16mm Ø)
1/2”
Contact rating
230Vac, 16A
SPDT
Data Sheet 21.002
Protection class - IP 40
Max head temperature - 80°C
FEATURES
• Simple installation and commissioning
• Cable gland supplied
• Manual reset
• Concealed setting for reset temperature
44
Input power
0...10Vdc
0...5vdc
0...20 psi
or 3...15 psi
45 psi
24Vac/dc nominal
INSTALLATION DETAILS
Indication - Output air pressure gauge (indication only)
Power on LED
Pressure increasing LED
Pressure decreasing LED
Head protection class - IP 65
Sensing range
Max supply
pressure
4...20mA
SFW
TWK 2301
Output signal
Data Sheet 25.021
Data Sheet 21.670
The TWK Thermostat is for water applications and
incorporate a single pole double throw contact switch.
Input signal
45
PRODUCT SELECTION
Satchwell Actuators
Zone Valves & Actuators
Zonemaster
Control System
(24Vac)
AVU 2201
Zone Valve
Actuator
(0-10vdz)
Zone Valve
Actuators
Control action
Thrust
24Vac
Reversing-modulating
105N
INSTALLATION DETAILS
Stroke - 11.5mm
Stroke time - 60 secs
Action - Reversing-modulating
Associated controllers - CZU, IAC, URC, MN
Manual override - Adjusted by means of a screwdriver slot in the top of the cover
Protection class - IP 41
FEATURES
• Simple installation and commissioning (self stroking)
• Direct coupling without the use of tools
• Built-in manual operator
• Connect up to seven AVU actuators in parallel from
one CZU or IAC controller output
These actuators operate Satchwell MB valves. The XRM is a
modulating actuator for use with Climatronic integral
controllers and the MMC controller. The RM is a 230V
reversing actuator for two-position control when used with a
changeover type thermostat or modulating control when
used with an appropriate controller. On power failure the
actuator can be operated manually.
Power supply
Input control
Control action
Thrust
AVE0001
24Vac, 50Hz
0...10Vdc
Direct acting
105N
AVE0002
24Vac, 50Hz
0...10Vdc
Reversing acting
105N
INSTALLATION DETAILS
Action - Direct or Reverse Acting specifications available
Stroke - Approximately 9.5mm
Stroke time - 60 secs
Associated controllers - DRTE, CZT, IAC, KMC, MMC, URC, MN, BAS, Sigma
Associated valves - VEU, MEU, FEU
Manual Override - Reset button on underside for use when manual override is
operated when AVE is powered up.
Protection class - IP 40
FEATURES
• Simple installation and commissioning (self
referencing)
• Direct coupling without use of tools
• Built-in Manual Operator and Override Reset
• Connect up to 10 AVE actuators in parallel from
one controller output
The ‘AR’ range of Reversing Actuators have a
rotary output for coupling to air dampers or
rotary valves requiring a rotary drive through
approximately 95°. These can be used for either
modulating or ON/OFF control depending on
the control signal supplied to the actuator.
FEATURES
• Normally open and normally closed models available
in both 230Vac and 24Vac
• Direct coupling to the ZY range of valves without the
need for linkage kits
• High performance duty for commercial HVAC
applications
• Positive spring return for fail safe operation
• Manual Override Lever
• ON/OFF Control
Power supply
Spring return
AY 1201
AY 1251
230Vac
230Vac
Normally closed
Normally open
AY 1301
AY 1351
24Vac
24Vac
Normally closed
Normally open
Rotary Actuators
Data Sheet 3.030
INSTALLATION DETAILS
Valve running time - Power stroke 9...11 secs, Spring return stroke 4...5 secs
Max different pressure - 350 kPa
Compatible valves - ZY range of Zone Valves
Compatible controllers - IAC, BAS, Sigma and thermostats
Manual operation - By means of a lever located on the side of the body
Protection class - IP 41
AVUE
Valve Actuators
(0-10V)
These proportional actuators utilise a linear output drive and
are used in conjunction with any controller providing a
0...10Vdc output signal. These control valves are applied,
typically, to regulate the flow of either hot or chilled water
supplying heating or cooling coils in various types of
terminal unit, for example fan coils units, reheat coils
associated with variable air volume units, also small air
handling plants and heat exchangers.
Valve Actuators
(pulsed)
FEATURES
• Compact size
• Hollow actuator drive output shaft
accommodates any length of damper shaft
without the need to cut it
• Simple to install, most dampers do not
require universal joints or rods
• Accommodates shaft diameters from
10...20mm and square shafts from
10...16mm square
• Stroke limiter supplied with the actuator
• Double insulated, no earth required
• 0...10V Feedback signal for monitoring
the actual actuator position via BMS
(ARE only)
Input control
Control action
Thrust
24Vac
0...10Vdc
Direct acting
220N
AVUE 4354
24Vac
0...10Vdc
Reversing acting
220N
• Direct coupling to all normal
dampers without mounting
brackets linkage kits
• Positive spring return operation
INSTALLATION DETAILS
Action - Reversing, modulating
Stroke - 12.7mm (1/2”)
Stroke time - 150 secs/50Hz, 125 secs/60Hz
Associated controllers - DRTE, CZT, KMC, MMC, IAC, URC, MN, BAS, Sigma
Associated valves - VEU, MEU, FEU, VZX, MZX
Manual operator - By thumb rotation of partially exposed gear wheel
Protection class - IP 40
FEATURES
• Simple to install. Direct coupling to valve without
use of tools
• Minimal commissioning. No site adjustments
required (self stroking)
• Compact size
• Built in manual operator
230Vac
(5VA)
230Vac/3A
Two-position (controlled by
changeover thermostat or switch).
Also suitable for CSC, CMC.
RMS, RXS, RES
Spring Return
Rotary Actuators
Power supply
Control action
Thrust
AVUX 4202
24Vac
Reversing-modulating
220N
AVUM 4601
230Vac
Reversing-modulating
220N
ARX 2252
ARX 2253
ARE 2302
ARE 2303
ARE 2304
ARE 2352
ARE 2354
ARE 2355
ARM 2606
ARM 2607
ARM 2656
ARM 2657
24Vac
24Vac
24Vac
24Vac
230Vac
230Vac
Input signal
Pulsed
24Vac
Pulsed
24Vac
0...10Vdc
0...10Vdc
Pulsed
230Vac
Pulsed
230Vac
Torque
15 Nm
8 Nm
15 Nm
8 Nm
15 Nm
8 Nm
Start & span
2202 - no
2203 - no
2252 - no
2253 - no
2302 - no
2303 - yes
2304 - yes
2352 - no
2354 - yes
2355 - no
2606 - no
2607 - no
2656 - no
2657 - no
Auxiliary switches
2202 - no
2203 - yes
2252 - no
2253 - yes
2302 - no
2303 - no
2304 - yes
2352 - no
2354 - yes
2355 - yes
2606 - no
2607 - yes
2656 - no
2657 - yes
Data Sheet 3.215
INSTALLATION DETAILS
Action - Reversing-modulating
Stroke time - 90...220 seconds
Angular stroke - 95°
Protection class - IP 54
Position indicator - Marked 0...10 representing
0...100% of the actuator stroke
Built-in
auxiliary switches
Running time
(approx)
RXS 7254
RXS 7255
LINKAGE
LK 2701
LK 2702
LK 2703
LK 2407
LK 2408
KIT ACCESSORIES
MBF 3-port Flanged Valves 65...100mm
MB 3-port Screwed Valves 1/2”...2”
VV Butterfly Valve 2...4”
Traditional Connection to Damper Boxes
Direct Damper Mounting Kit
RES 7354 RMS 7654 RMS 7655 RXS 7256
RXS 7257
RES 7355 RMS 7656
RMS 7657
24Vac
24Vac
24Vac
230Vac
230Vac
24Vac
24Vac
230Vac
Pulsed
24Vac
Pulsed
24Vac
0...10Vdc
Pulsed
230Vac
Pulsed
230Vac
Pulsed
24Vac
0...10Vdc
Pulsed
230Vac
15 Nm
15 Nm
15 Nm
15 Nm
15 Nm
4 Nm
4 Nm
4 Nm
-
2 SPDT
(3A)
-
-
-
1 SPDT (1.5A)
(7657 only)
150s
150s
150s
150s
150s
40...70s
INSTALLATION DETAILS
Action - Open/close
Angular stroke - 95°
Protection class - IP 54
Data Sheet 3.005
INSTALLATION DETAILS
Action - Reversing, modulating
Stroke - 12.7mm
Stroke time - 100 secs
Associated controllers - CSC, MMC, CXT, CXR, IAC, URC, MN, BAS, Sigma
Associated valves - VEU, MEU, FEU, VZX, MZX
Manual operator - By thumb rotation of partially exposed gear wheel
Protection class - IP 40
ACCESSORY AVUA 1752 Rain Protection Cover
46
RM 3601
Power supply
ACCESSORY AVA 1752 Rain Protection Cover
FEATURES
• Simple to install. Direct coupling to valve without
use of tools
• Minimal commissioning. No site adjustments
required (self stroking)
• Compact size
• Built in manual operator
Integral (controlled by CXT, CXR,
CSC, MMC, URC or IAC
Data Sheet 3.305/3.310
Data Sheet 3.001
These valve actuators are designed to be used on the VZX
two port and the MZX three port valves. The AVUX is a
24 volt ac reversing actuator suitable for modulating the
VZX and MZX valves from any 24 Volt ac controller or
device. The AVUM is a mains Voltage reversing actuator and
can be controlled from any controller or device having a
mains switched output.
AVUX, AVUM
Power supply
AVUE 4304
Application
24Vac/0.02A
ARX 2202
ARX 2203
These actuators have a rotary output
for direct coupling to air dampers.
Models are available for on/off
Power supply
operation from 230V or 24V power
supplies. There is also a 0...10Vdc input Input signal
version that is fully modulating.
Torque
FEATURES
Mid-sized Actuators
Transfer switch
24Vac
(0.5VA)
INSTALLATION DETAILS
Stroke - 90° angular in 4 minutes. Reversing
Torque - 2 Nm
Associated valves - MB valves (3-port)
Actuator position indicator - Marked 0...10 visible from both sides
Transfer switches - Two single pole. Not electrically separate
Protection class - IP 41
Modulating and
Two-position Light
Duty Actuators
ARX, ARE,
ARM
Power supply
XRM 3201
Data Sheet 3.201
RM, XRM
Data Sheet 3.011
The AY range of actuators has been designed for use on the
ZY range of Zone Valves in ON/OFF HVAC applications. They
mount directly onto the valves without the need for linkages
or calibration. Flexibility is provided with the variety of
voltages and functions, all making for ease of installation.
AY
Power supply
Data Sheet 3.010
The AVE 24Vac zone valve actuator is designed for use on
the Satchwell VEU, MEU and FEU valves and is used in
conjunction with any controller providing a 0-10Vdc output
signal. The AVE has a linear output and is suitable for use on
hot or chilled water applications on terminal units.
AVE
PRODUCT SELECTION
Rotary Actuators
The AVU Mk 2, 24Vac Valve Actuator is designed for use on
Satchwell zone valves such as the VEU, MEU and FEU. The
AVU has a linear output and is suitable for use on hot or
chilled water applications on terminal units. The AVU is
controlled by the Satchwell CZU, IAC, URC and MicroNet MN
controllers.
AVU Mk2
Satchwell Actuators
47
2 SPDT 1 SPDT (1.5A)
(3A)
(7257 only)
150s
40...70s
PRODUCT SELECTION
Satchwell Actuators
Linear Actuators
ALi 1576
ALi 1577
ALi 1676
ALi 1677
0...10Vdc feedback
No
Yes
No
Frame
Standard
Short
Short
Standard
Power supply
Input signal
The ALi has several modes of operation, from start and span
settings to reverse acting including two safety modes. It
incorporates a manual override with a gear train
disengagement feature by means of a manual operation key
located on top of the case.
Intelligent Linear
Actuators
0...10Vdc, 0...4Vdc, 6...10Vdc, 2...10Vdc (safety mode)
700N
Running speed
ZY
1 s/mm
Max stroke
38mm
38mm
Auxiliary switches
25mm
25mm
Use kit ALA 1211 (2 x 5A, 250V adjustable)
2 and 3-port
Zone Valves
INSTALLATION DETAILS
Stroke - 0...38mm max (11/2”)
Associated controllers - CZT Mk 5 (separate transformer required), IAC, KMC, MMC,
MN 440, MN 500, MN 620, URC, BAS, Sigma
Associated 2-port valves - VSF, VZF, VZ
Associated 3-port valves - MJF, MZF, MZ
Type of operation - Reversing, modulating
Protection class - IP 54
Drive - Operates on screw-jack principle. Ultra reliable
Spindle coupling - Freely rotating coupling, screwed 3/8” (24UNF)
Manual operator and override - Hand operator with gear train disengagement failure
Satchwell Linear Actuators type ‘AL’ are
reversing actuators having a linear output, for
direct coupling to Satchwell lift and lay seattype control valves or other seat valves
requiring a linear driver over stroke lengths of
up to 38mm (11/2”), within the limits of output
thrust and with compatible mounting
arrangements.
Linear Actuators
The ALE actuator can be set to operate a low
hysteresis when used for tight control
applications on microprocessor based
controllers such as the KMC and MMC.
FEATURES
• Direct coupling to Satchwell and third
party valves
• Universal for valve strokes, up to 38mm
(11/2”). Actuator stroke is self-setting to
suit valve stroke
• Alternative stroke times, to suit
application
• Standard or low hysterisis selection on
ALE types
ALX 1201
Frame
Power supply
Input signal
Thrust
Running speed
Max stroke
Auxiliary switches
ALX 1251
ALE 1302
Standard
Short
24Vac
24Vac
Pulsed 24Vac
Pulsed 24Vac
ALE 1352
ALM 1601
Standard
Short
Standard
24Vac
24Vac
230Vac
0...10Vdc
0...10Vdc
Pulsed 230Vac
538N
311N
538N
311N
538N
8.5 s/mm
5.0 s/mm
8.5 s/mm
5.0 s/mm
8.5 s/mm
38mm
16mm
38mm
16mm
38mm
Use kit
ALA 1211
1 x 5A, 250V
fixed, built-in
Use kit
ALA 1211
1 x 5A, 250V
fixed, built-in
Use kit
ALA 1211
ALXS, ALES,
ALMS
Spring Return
Linear Actuators
Accessories
for ‘AL-’ Type
Actuators
The ALES actuator can be set to operate a low
hysteresis when used for tight control
applications on microprocessor based
controllers such as the CZT, KMC and MMC.
FEATURES
• Positive power failure operation
• Patented maintenance free air brake
system
• Spring return action to ‘spindle retracted’
or ‘spindle extended’ position
• Direct coupling to Satchwell and third
party valves
• Universal for valve strokes, up to 25.4mm
(1”). Actuator stroke is self-setting to suit
valve stroke
• Standard or low hysteresis selection on
ALES types
2, 3 and 4-port
Unit Valves
1/2”
3/4”
1/2”
3-port
BSP (female),
parallel fitting
1/2”
1/2”
3/4”
3/4”
3/4”
Cvs
Max ∆p (kPa)
1201
1202
1203
1204
1205
1206
1.0
2.6
3.6
3.6
5.2
7.3
350
350
350
175
175
175
AY
AY
AY
AY
1201
1251
1301
1351
–
–
–
–
230Vac NC
230Vac NO
24Vac NC
24Vac NO
ZY
ZY
ZY
ZY
ZY
ZY
1301
1302
1303
1304
1305
1306
1.0
2.6
3.6
3.6
3.6
7.3
350
350
350
175
175
175
AY
AY
AY
AY
1201
1251
1301
1351
–
–
–
–
230Vac NC
230Vac NO
24Vac NC
24Vac NO
Data Sheet 4.001
This range of characterised Plug and Seat Control Valves for
operation by AVU actuators and principally for use in
conjunction with the CZU temperature controller, IAC
controllers and MicroNet MN controllers. The valves are
designed to regulate the flow of hot or chilled water to air
heaters and coolers in fan coil units, induction units, small
hot water re-heaters associated with V.A.V units or other
similar types of terminal unit for the control of room
temperature.
Size
Type
Flow
1/2”
2-port
BSP (male),
parallel fitting
1/2”
1/2”
3/4”
1/2”
3-port
BSP (male),
parallel fitting
1/2”
1/2”
3/4”
FEATURES
• Small compact unit valves
• Wide range of Kv/Cv values
• Long plug travel improves performance and reduces
the risk of blockage
• Direct coupling actuators
3/4”
4-port
BSP (male),
parallel fitting
The ZVX 2-port Flow Control and 3-port Diverter Valves are
for the regulation of low pressure heating and chilled water
circuits where on/off control is required.
FEATURES
• Complete compact unit; no site assembly required
• Two-wire control with positive spring return
ZVX
ALXS 1201
ALXS 1251
ALES 1302
ALES 1352
Power supply
24Vac
24Vac
24Vac
24Vac
ALMS 1601 ALMS 1651
230Vac
230Vac
Input signal
Pulsed
24Vac
Pulsed
24Vac
0...10Vdc
0...10Vdc
Pulsed
230Vac
Pulsed
230Vac
2 and 3-port
Zone Valves
Compatible actuators
ZY
ZY
ZY
ZY
ZY
ZY
Cvs
Bypass
INSTALLATION DETAILS
Valve type - Paddle
Power supply - 230Vac, 50Hz
Operation - 2-port valve: NC, 3-port valve: Port A is NC
Pipe connections - BSP parallel female or compression
(includes nuts and olives)
Temperature
limits
Max internal
pressure (kPa)
VEU
VEU
VEU
VEU
4414
4415
4416
4626
0.63
1.0
1.6
4.0
–
–
–
–
2...120°C
2200
MEU
MEU
MEU
MEU
MEU
4422
4423
4425
4626
4627
0.63
1.0
2.0
4.0
6.0
–
–
–
–
–
2...120°C
2200
FEU
FEU
FEU
FEU
FEU
FEU
FEU
FEU
6414
6415
6416
6451
6452
6454
5626
5627
0.63
1.0
2.0
0.63
1.0
2.0
4.0
5.6
0.5
0.7
1.4
0.5
0.7
1.4
2.8
4.0
2...120°C
2200
1/2”
1/2”
1/2”
15mm
15mm
15mm
3/4”
3/4”
Data Sheet 4.101
INSTALLATION DETAILS
Action - Reversing-modulating
Stroke time - 5 sec/min minimum (see data sheet for other actuator/valve stroke times)
Protection class - IP 54
Associated controllers - ALX: MMC, CXR, CSC, CXT, IAC, MicroNet, URC
ALE: MMC, KMC, CZT, MicroNet, IAC (sensors DRTE, DDTE, DWTE), BAS, Sigma
ALM: CSC
Associated valves - See valve data sheets
Drive - Operates on screw-jack principle
Spindle coupling - Freely rotating coupling, screwed: 3/8” 24-UNF, female (ALM 1601, ALX 1201, ALE
1302), 1/4” 32-UNEF, female (ALX 1251, ALE 1352)
Thrust
1/2”
3/4”
FEATURES
• Suitable for chilled and hot water applications, up to
50% glycol
• Range of actuators available for direct connection
• 100% tight shut-off
INSTALLATION DETAILS
Power supply - 24Vac
International pressure rating - PN 22
Data Sheet 3.401
ACCESSORIES - see below
‘AL-S’ Actuators are power failure return types
having a linear output, for direct coupling to
Satchwell lift and lay seat-type control valves.
They are also suitable for other seat valves
requiring a linear drive over stroke lengths of
up to 25.4mm (1”), within the limits of output
thrust, with compatible mounting arrangements
and spindle projections.
VEU, MEU,
FEU
Type
1/2”
3/4”
INSTALLATION DETAILS
Pipe connections - BSP parallel female
Operating pressure limits - 300 PSI - PN20 (2,100kPa)
Seat leakage - 100% tight shut-off - (zero leakage)
Valve type - Paddle action
Data Sheet 3.601
FEATURES
• Self-stroking
• Various operating modes
• Direct coupling to Satchwell and 3rd party seat valves
• Electronic control of thrust under stall conditions
• LED indication of actuator status
• Safety modes in the event of controller failure
reducing software engineering
• Selectable resolution 200 or 25 steps
• No need to re-stroke after power failure
• 0...10V feedback (ALi 1577 & 1677)
Size
2-port
BSP (female),
parallel fitting
It is imperative that the valves be piped so that the paddle
closes against the direction of the flow.
34Vdc or 24Vac
Thrust
The ALi has the ability to provide a 0...10V feedback signal
for monitoring purposes.
This range of Zone Valves are designed to be used with the
AY range of actuators. The use of these valves in open
systems is not recommended.
Yes
ACCESSORIES - see below
ALX, ALE,
ALM
PRODUCT SELECTION
Small Valves
The Satchwell ALi is an Intelligent Linear Actuator providing
a modulating output for the control of two and three port
seat valves with a stroke of up to 38mm (11/2”). It is selfstroking, automatically adjusting for any valve within the
stroke range.
ALi
Satchwell Valves
(fittings not provided)
Size
Type
Cvs
Temperature
limits
Max differential
(kPa)
2-port
BSP (female),
parallel fitting
1/2”
ZVX 4201
ZVX 4202
ZVX 4203
3.2
4.5
5.8
5...110°C
200
150
100
3-port
BSP (female),
parallel fitting
1/2”
ZVX 4301
ZVX 4302
ZVX 4303
3.8
5.8
5.8
5...110°C
200
200
200
ZVX 4401
5.8
5...110°C
200
3/4”
1”
3/4”
1”
3-port
22mm
compression fitting
Data Sheet 24.001
311N
Running speed
Spring return speed
Max stroke
Auxiliary switches
7 s/mm
These valves are designed to control heating/cooling coils in
terminal units such as fan coils and reheat coils.
0.3 s/mm
25.4mm
The thermo-electric actuator is suitable for either on/off or
pulse width modulation operation.
2 x 5A, 250V fixed, built-in
Data Sheet 3.501
INSTALLATION DETAILS
Action - Reversing-modulating
Stroke time - 8.5 sec/min minimum (see data sheet for other actuator/valve stroke times)
Spindle coupling - Freely rotating coupling, screwed: 3/8” 24-UNF, female, adaptor to 1/4” 32-UNEF,
female, supplied fitted
Protection class - IP 54
Associated controllers - ALXS: MMC, CXR, CSC, CXT, IAC, MicroNet, URC
ALES: MMC, KMC, CZT, MicroNet, IAC (sensors DRTE, DDTE, DWTE), BAS, Sigma
ALMS: CSC
Associated valves - VZ, MZ, VSF, MZF, VZF, MJF (up to 25mm stroke)
Size
VEX, MEX,
FEX, AVX,
AVM
2, 3 and 4-port
Electro-thermic
Valves
FEATURES
• Small compact valves particularly suitable for
mounting in small enclosures
• Fly lead for easy electrical connection
INSTALLATION DETAILS
Power supply - AVX: 24Vac ±10%. AVM: 230Vac ±10%
Thrust - 110N
International pressure rating - PN16
Protection class - IP 44
Operation - On/off pulse width modulation
Associated devices - AVX - IAC, BAS, Sigma
AVM - Thermostats and time clocks
48
49
Cvs
Temp.
limits
2-port
BSP (male)
1/2”
VEX 7201 0.2-1.9 4...100°C
3-port
BSP (male)
1/2”
MEX 7301
4-port
BSP (male)
1/2”
Data Sheet 24.020
Auxiliary switches – ALA 1211 Available for internal mounting. Two voltage-free change-over switches rated 5A, 250V
Spindle adaptor – LNK 1402 1/4” 32-UNEF female x 3/8” 24-UNF male. One supplied with each actuator, except ALX
1251 and ALE 1352, for which it is not required
Rain protection cover – ALA 1751
Type
FEX 7401
1.7
1.7
4...100°C
4...100°C
Mode
Max. diff. pressure (bar)
AVX 7201
AVX 7251
AVM 7301
AVM 7351
(NO)
(NC)
–
7
7
2.5
Mix
2.5
Divert
3
7
Mix
2.5
2.5
Divert
3
7
(fittings not provided)
PRODUCT SELECTION
Satchwell Valves
2-port Valves
3-port Valves
Size
These seat valves are of ‘Globe’ construction with a linear
moving spindle and equal percentage characterised plug
which closes against the seat when the spindle is lifted.
2-port Seat Valves
VZ, VZF, VSF
2-port Seat Valves
1/2”
VZX
Screwed,
bronze
The valves are suitable for the control of hot or chilled
water and brine or glycol solutions within their limits – see
data sheet. They are suitable for operation by the AVUX,
AVUM and AVUE actuators only.
VZX
Satchwell Valves & Linkage Kits
3/4”
1”
11/4”
1
1 /2”
2”
INSTALLATION DETAILS
Pipe connections - Screwed BSP to BS 21 female – taper
Screwed BSP to BS21 female - parallel
Characteristic - Equal percentage
Rangeability - 50:1
International pressure rating - PN16
Data Sheet 4.401
These seat valves are of ‘Globe’ construction with a linear
moving spindle and equal percentage characterised plug
which closes against the seat when the spindle is lifted.
They are suitable for the control of hot or chilled water,
steam, brine or glycol solutions within their limitations
– see data sheet.
Size
Type
VZX
VZX
VZX
VZX
VZX
VZX
4404
4451
4501
4551
4601
4651
Cvs
Stroke
Max ∆p
pressure (kPa)
Temperature
limits
2
4
8
12
20
32
12.7mm
1180
720
340
200
120
60
2...120°C
MZ, MZF, MJF
3-port Seat Valves
1/2”
VZ
Screwed
bronze
Cvs
Stroke Max ∆p Temperature limits
pressure
(max internal
(kPa)
pressure kPa)
1401
1402
1403
1404
1451
0.2
0.5
1.0
2.0
4.0
9.5mm
3/4”
VZ
VZ
VZ
VZ
VZ
INSTALLATION DETAILS
Pipe connections - Screwed BSP to BS 21 female - taper
Screwed BSP to BS 21 female - parallel
Flanged BS 4504 16/11. = DIN 2533 ND 16
Control medium - Brine, 15% max. NaCl or CaCl2 (freeze
protection), Glycol solution, 25% max. (freeze protection)
International pressure rating - PN16
MJF
Flanged
cast iron
2...130°C
at (1500 kPa)
or 2...120°C
at (1600 kPa)
–
–
–
–
–
1”
11/4”
1
1 /2”
2”
VZ
VZ
VZ
VZ
2501
2551
2601
2651
8
12
20
32
15.9mm
970
580
410
240
2...200°C
at (1300 kPa)
or 2...120°C
at (1600 kPa)
823-2-801
”
”
”
15mm
15mm
15mm
15mm
15mm
VSF
VSF
VSF
VSF
VSF
2426
2427
2428
2429
2430
0.63 9.5mm
1.0
1.6
2.5
4.0
1600
1600
1600
1600
1600
“
–
–
–
–
–
20mm
25mm
VSF 1476
VSF 1526
6.3 15.9mm
10
1600
1170
“
–
823-2-801
32mm
40mm
50mm
VSF 1576
VSF 1626
VSF 1676
16
25
40
640
400
240
“
823-2-801
”
”
65mm
80mm
100mm
VZF 1727
VZF 1777
VZF 1852
63 25.4mm
80
125
140
100
50
“
–
–
–
125mm
150mm
VZF 1902
VZF 1954
200
315
28
18
“
–
–
1/2”
VSF
Flanged
SG iron
VSF
Flanged
cast iron
24.5mm
38mm
MZF
Flanged
cast iron
Spring
access.
kit
1600
1600
1600
1600
1600
1/2”
1/2”
INSTALLATION DETAILS
Pipe connections - Screwed BSP to BS 21 female - taper
Screwed BSP to BS 21 female - parallel
Flanged BS 4504 16/11 = DIN 2533 ND 16
Face to Face dimension to DIN 3300
International pressure rating - PN16
Type
Max ∆p
Temperature limits
pressure (kPa) (max internal pressure kPa)
Size
Type
Cvs
Stroke
1/2”
MZ 3402
MZ 3452
2.5
4
9.5mm
1600
1600
1”
11/4”
11/2”
2”
MZ
MZ
MZ
MZ
3501
3551
3601
3651
8
12
20
32
15.9mm
970
580
410
240
15mm
15mm
MJF 3426
MJF 3427
1.0
4.0
9.5mm
1600
1600
20mm
25mm
MJF 3476
MJF 3526
6.3
10
15.9mm
1300
850
32mm
40mm
50mm
MJF 3576
MJF 3626
MJF 3676
16
25
40
24.5mm
550
350
220
65mm
80mm
100mm
MZF 3729
MZF 3779
MZF 3854
63
80
125
25.4mm
140
100
50
125mm
150mm
MZF 3904
MZF 3958
200
315
38mm
28
18
3/4”
2...200°C
at (1300 kPa)
or 2...120°C
at (1600 kPa)
2...200°C
at (1300 kPa)
or 2...120°C
at (1600 kPa)
2...200°C
at (1300 kPa)
or 2...120°C
at (1600 kPa)
Data Sheet 4.610
Satchwell Actuators to Satchwell Valves and Dampers
LK 2701, 2702,
2703, 2408,
2407
RM, XRM, ARM, ARX, ARE Actuators to ...
Valve type
Suitable actuators
Linkage kit
Comprises
Valve type
Suitable actuators
Linkage kit
Comprises
MB Valves
1/2”...2”
RM, XRM
None
require
–
Dampers
LK 2407
(866-2-407)
ARM 2657
ARX 2253
ARE 2354
LK 2702
(826-2-702)
Bracket
2 x screws
Output shaft adapter
MBF Valves
65...100mm
ARM 2607
ARX 2203
ARE 2304
LK 2701
(826-2-701)
Bracket
Actuator crank with pin
Valve crank with slot and
manual override lever
ARM 2607
ARX 2203
ARE 2304
ARM 2657
ARX 2253
ARE 2354
Bracket
Output shaft
Adjustable crank
Universal coupling
Universal coupling for
damper
LK 2408
(866-2-408)
Anti-rotation bracket
Stroke limiter
VV Valves
2...4”
ARM 2607
ARX 2203
ARE 2304
LK 2703
(826-2-703)
Bracket, linkage, screws
and spring
ARM 2607
ARX 2203
ARE 2304
ARM 2657
ARX 2253
ARE 2354
Data sheet 5.001
Data sheet 5.001
Data Sheet 4.410
Satchwell Actuators to Third Party Valves
3-port Valves
These 3-port Rotary-shoe Type Valves are characterised for
use as mixing or diverting, with hot or chilled water, in
heating, ventilating and air conditioning applications.
Size
ACCESSORIES
Reconditioning Kits
617-9-410 MB 1/2...1”
617-9-411 MB 11/4”
617-9-412 MB 11/2”
617-9-413 MB 2”
Cvs
Max internal
pressure (kPa)
Temperature
limits (kPa)
1402
1452
1502
1552
1602
1652
1.8
4.0
8.0
12.0
20.0
32.0
1000
2...120°C
65mm MBF 4732
80mm MBF 4782
100mm MBF 4857
63
80
120
600
1.8
4.0
8.0
12.0
20.0
32.0
1000
1/2”
MB
3/4”
Screwed
BSP parallel 1”
female
11/4”
11/2”
2”
INSTALLATION DETAILS
Pipe connections - Screwed parallel (female) BSP to BS 21
Flanged BS 4504, Table 6/11
International pressure rating - MB: PN10,
MBF: PN6
MBF
Flanged
1/2”
MBX
3/4”
Screwed
BSP parallel 1”
female
11/4”
11/2”
2”
618-9-510 MBF 65mm
618-9-511 MBF 80mm
618-9-512 MBF 100mm
3-port Rotary
Valves
Type
MB
MB
MB
MB
MB
MB
MBX
MBX
MBX
MBX
MBX
MBX
4401
4451
4501
4551
4601
4651
LNK
LNK
LNK
LNK
LNK
LNK
LNK
2...120°C
LS01
HW01
FS01
FS02
HY01
HY02
IN01
2...110°C
Data Sheet 4.501 & 4.502
These ‘Globe’ construction valves are suitable for the control
of hot or chilled water and brine or glycol solutions within
their limits - see DS 4.601. They are suitable for operation by
the AVUM, AVUX and AVUE actuators only.
3-port Seat Valves
MZ
Screwed
bronze
ACCESSORIES
Replacement Gland Kits
626-9-203 MZ, MJF
626-9-311 MZF
VZF
Flanged
cast iron
MZX
(cont)
These ‘Globe’ construction Seat Valves are suitable for the
control of hot or chilled water and brine or glycol solutions
within the limits below.
ACCESSORY
626-9-204 Replacement Gland Kit
ACCESSORIES
Replacement Gland Kits
626-9-203
VZ, VSF 15, 20 & 25mm
667-9-201
VSF 32...50mm
626-9-311
VZF
Spring Accessory Kit 823-2-801- Available for use in
conjunction with ALM 1601, ALX 1201, ALE 1302, to increase
maximum differential pressure.
MB, MBF, MBX
PRODUCT SELECTION
Size
MZX
Screwed
BSP bronze
INSTALLATION DETAILS
Pipe connections - Screwed BSP to BS 21 female - taper
Screwed BSP to BS 21 female - parallel
Control medium - Brine, 15% max. NaCl or CaCl2 (freeze
protection), Glycol solution, 25% max. (freeze protection)
International pressure rating - PN16
1/2”
3/4”
1”
11/4”
11/2”
2”
Data Sheet 4.601
ACCESSORY
626-9-204 Replacement Gland Kit
50
Type
MZX
MZX
MZX
MZX
MZX
MZX
4402
4452
4501
4551
4601
4651
Cvs
Stroke
Max ∆p
pressure
(kPa)
Max internal
pressure
(kPa)
Temp.
limits
2.5
4
8
12
20
32
12.7mm
1180
720
340
200
120
60
1600
2...120°C
ALX, ALE, ALM, ALi Actuators* to ...
Valve type
Linkage kit
Comprises
Landis & Staefa
VVF and VXF 20mm valve stroke
LNK LS01
–
Honeywell
V5011A 20mm valve stroke
LNK HW01
–
Fisher
Y body 3/4”...11/2”, A body 11/2”
Y body 2”...3”, A body 2”...4”
LNK FS01
LNK FS02
–
–
Hymatic
1700 3/4”...11/2”, 1450 11/4”, 1400R 11/2”
1400R 2”...3”, 1700 2”...3”
LNK HY01
LNK HY02
–
–
Siebe
VB valves up to 2”
LNK IN01
–
Data sheet 3.601
* Not ALX 1251 and ALE 1352
Transformers
If mains voltage electricity supply is available locally,
e.g. at a fan coil unit, it is convenient to use one transformer
for each control system. If mains supply is not available
locally it may be more convenient to use a larger central
transformer.
TR1
TR2
TR3
TR4
TR5
Two fly leads are provided for the primary and secondary
electrical connections, for ease of installation.
230Vac/24Vac
Isolating
Transformers
Code
Size
871-1-201
871-1-202
871-1-203
871-1-204
871-1-205
25VA
50VA
80VA
200VA
300VA
Data Sheet 25.001
These transformers conform to EN 60742.
51
INSTALLATION DETAILS
Primary - 230V, 50/60 Hz
Secondary - 24V r.m.s.
Electrical connections 3-core input (fly lead) cable, 0.5m long
2-core output (fly lead) cable, 0.5m long
PRODUCT SELECTION
Satchwell Linkage Kits & Spares
PRODUCT COMPATIBILITY
CSC Controller
Spares
Actuators
Satchwell Controllers & Sensors
MMC Controllers
DRT DRT DWT DWT DST DOT
3451 3453 0001 0002 0001 0002
PCB Board
Model
Description
Part number
Data sheet
ALE
ALES
Circuit board
”
477-9-241
477-9-241
3.401
3.501
Adjustable scale
Location
Spec. no.
Time
control
Compensators
CSC 5252
None
CSC 5352
Controllers
exp. none none none none none
room room imm. imm. clamp outs.
Adjustable scale
Location
Spec. no.
Output
230V or
24Vac
Digital
Data sheet DS 2.021
Product Selection - page no.
DRT
3453
none
room
Control
Batteries
Model
Model
Description
Part number
Data sheet
CSC
SVT
Analogue T/S
”
561-9-260
561-9-260
2.021
2.001
CSC
SVT
Digital T/S
”
561-9-261
561-9-261
2.021
2.001
●
●
●
●
●
●
●
●
●
●
●
●
39
39
42
42
42
43
CMC 1
CMC 3 – – –
CSMC 3 – – –
MMC 2 – – –
MMC 3 – – –
SMT
SVT
–
–
–
–
–
–
–
Part number
Micro Management Controller with built-in time schedules
MMC 4701 –40...150°C
Pulsed
●
●
●
24V or
0...10Vdc
561-9-220
563-9-231
563-9-231
563-9-231
563-9-231
563-9-231
588-9-210
–
–
–
–
–
–
2.001
Adjustable scale
Location
Spec. no.
Time
control
Optimisers
SVT 4201 Analogue
Data sheet
851-2-401
–
Adjustable scale
Location
none none none none none none none exp.
room room imm. imm. clamp outs. outs. room
Spec. no.
230V
on/off
Digital
Control
none
room
Valves
Adjustable scale
Location
Spec. no.
Lug Nuts
Part number
626-9-313
626-9-312
valves
21/2”...6” valves
DOT,
DOS
none
outs.
DOW
2701
none
outs.
RPW
4425
exp.
room
●
●
●
●
●
●
●
●
●
●
42
42
43
43
43
Control
Climatronic
CXT 5605 –10...120°C
Data sheet
–
–
● (included)
Data sheet DS 2.701
Product Selection - page no.
39
39
42
42
42
43
43
41
43
DRT
3451
exp.
room
DRT
3453
none
room
DRT
3801
exp.
room
DRT
3851
exp.
room
DDT
0001
none
duct
DDU
0001
none
duct
DDU
1803
none
duct
●
●
●
●
●
●
●
39
39
40
40
41
41
41
CZU Controller
exp. none exp. none none none none exp.
room room room duct imm. imm. clamp room
Adjustable scale
Location
Spec. no.
24V
modulating
●
●
●
●
CZT 5305 –10...120°C 0...10Vdc
●
●
●
●
●
●
●
CXR 5805 –10...120°C
●
●
●
●
●
●
●
39
39
39
41
42
42
42
Data sheet DS 2.101, 2.105, 2.110
Product Selection - page no.
40
43
Output
24V
modulating
none
duct
RPW
4425
exp.
room
Output
DRT DRT DRT DDT DWT DWT DST RPW
3451 3453 3651 0001 0001 0002 0001 4425
1/2”...2”
41
● (included)
CXT, CZT, CXR Controllers
Description
39
Micro Management Controller with built-in time schedules
MMC 4701 20...90%rh
Pulsed
●
●
●
24V or
0...10Vdc
Output
Product Selection - page no.
Part number
39
DRTH DDTH
DR DRT DWT DWT DST DOT DOS RPW
3253 3453 0001 0002 0001 0002 0001 4425
Pockets
Description
DST
0001
none
clamp
Output
Data sheet
SVT 4251
(T) Range 125mm immersion
DWT
0001
none
imm.
SVT Controllers
Description
Sensors
Model
DDT
0001
none
duct
District Heating Controller
MMC 4601 –40...150°C 0...10Vdc
Data sheet DS 2.751, 2.701
Product Selection - page no.
Clocks
DRT
3651
exp.
room
Control
Output
Zonemaster
CZU 4201
10...40°C
24V
Data sheet DS 2.201
Product Selection - page no.
43
1
MN Controllers (LONMARK®)
KMC Controller
Replacement Gland Nut and Tube of Grease Kits
Model
Description
Part number Data sheet General notes
MEU
MJF
MZ
FEU
VEU
VJF
VSF
VZ
MZX
VZX
–
–
1/2”...2” valves
–
–
–
15...25mm
1/2”...2” valves
1/2”...2” valves
1/2”...2” valves
623-9-201
626-9-203
626-9-203
623-9-201
623-9-201
626-9-203
626-9-203
626-9-203
626-9-204
626-9-204
4.101
4.610
”
4.101
”
4.610
4.110
4.110
4.601
4.101
Adjustable scale
Location
Spec. no.
– series 3 valves
Reconditioning Kits
Model
Description
Part number
MB
1/2”...1”
valves
11/4” valves
11/2” valves
2” valves
617-9-410
617-9-411
617-9-412
617-9-413
4.501
”
”
”
65mm valves
80mm valves
100mm valves
618-9-510
618-9-511
618-9-512
4.501
”
”
– series 1 & 2 valves
MBF
Data sheet
Control
DRT
3453
none
room
DRT
3451
exp.
room
DDT
0001
none
duct
DWT
0001
none
imm.
DST
0001
none
clamp
Adjustable scale
Location
DOT DRTH DDTH RPW
0002
4425
none none none exp.
outs. room duct room
Data sheet DS 2.101, 2.105, 2.110
Product Selection - page no.
●
●
●
●
●
●
●
●
●
39
39
41
42
42
43
40
41
43
MN
MN
MN
MN
MN
MN
DDU
0001
none
duct
DOT
DOS
none
outs.
DOW
2701
none
outs.
DRH
DRTH
none
room
DDH
DDTH
none
duct
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
39
39
40
33
42
42
43
43
43
40
41
Note 1: MN-S1 is not adjustable, MN-S2/3/4/5 are adjustable
URC, BRC Controller
MN Controllers (Bus-du-jour®)
1
DU
1
Adjustable scale
Location
DUS MN-S
1-5
none exp. note1
room room room
DDU
0001
none
duct
DDT
0001
none
duct
Adjustable scale
Location
Spec. no.
Replacement Gland Assembly, Gland Nut and Tube of Grease Kits
Model
Description
Part number Data sheet General notes
MZ
MZF
VSF
VZ
VZF
1/2”...2”
626-9-310
626-9-311
667-9-201
626-9-310
626-9-311
4.610
”
”
4.110
”
11/13
50
100
150
200
VAV
Product Selection
- page no.
2
valves
65...150mm
32...50mm
1”...2” valves
65...150mm
DST
0001
none
clamp
Spec. no.
Output
Keyboard
KMC 3201 –40...150°C 0...10Vdc
or
0...100% rh
DRT DRT DU MN-S DWT
3453 3651/2 4301 1-5 0001/2
none yes none note1 none
room room room room imm.
– series 1 valves
– series 1 valves
– series 1 valves
Reconditioning Kit
Model
Description
Part number
VV
2”...4” valves
618-9-210
Data sheet
–
DWT
0001/2
none
imm.
DST
0001
none
clamp
DDU
0001
none
duct
DOT,
DOS
none
outs.
DOW
2701
none
outs.
RPW
4425
exp.
room
DRH
DRTH
none
room
DDH
DDTH
none
duct
Spec. no.
UniFact Pro
URC-41
URC-51
●
●
●
●
●
●
●
●
●
●
Bonsai
BRC-41 (Pro)
BRC-51 (Lite)
●
●
●
●
●
●
●
●
●
●
Data sheet DS 10.130 & 4.103
Product Selection - page no.
40
40
33
41
41
MN
MN
MN
MN
300
440
500
620
Product Selection
- page no.
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
39
39
43
33
42
42
41
43
43
43
40
41
Note 1: DU 4301 is non adjustable, DUS 4302 and DUSF 4351/4352 are adjustable
Note 2: MN-S1 is not adjustable, MN-S2/3/4/5 are adjustable
Note 1: MN-S1 is not adjustable, MN-S2/3/4/5 are adjustable
52
DRT DRT DU MN-S
3453 3651/2 DUS 1-5
none yes note1 note2
room room room room
53
24V
8
Types
std
std
Force (N)
538
538
8
ALE
1302
ALE
1352
ALi
1576
1577
24V 0..10V 0..10V 0..10V
24V 24V
24V
short std short s.fast*
ALi
1676
1677
0..10V
24V
s.fast*
CvS
MB Screwed, BSP parallel, female, rotary shoe (2...120°C max water)
1/2”
MB 1402 1.8
●
●
LK2702
3/4”
MB 1452
4
●
●
LK2702
1”
MB 1502
8
●
●
LK2702
1
●
●
LK2702
1 /4” MB 1552 12
1
●
●
LK2702
1 /2” MB 1602 20
2”
MB 1652 32
●
●
LK2702
MBF Flanged, table 6/11, BS 4504, rotary shoe (2...120°C max water)
65mm MBF 4732 63
X
X
LK2701
X
80mm MBF 4782 80
X
X
LK2701
X
100mm MBF 4857 120
X
X
LK2701
X
Size
X
X
X
X
X
X
MBX Screwed, BSP parallel, female, rotary shoe (2...110°C max water)
1/2”
MBX 1401 1.8
●
●
LK2702
3/4”
MBX 1451 4
●
●
LK2702
1”
MBX 1501 8
●
●
LK2702
●
●
LK2702
11/4” MBX 1551 12
●
●
LK2702
11/2” MBX 1601 20
2”
MBX 1651 32
●
●
LK2702
47
47
47
47
47
47
47
47
X NOT compatible
Spec. no.
311
538
511
700
230V
24V
0..10V
24V
spring spring spring
return return return
311
311
700
VZ Screwed, bronze, hot/chilled water,
1/2”
VZ 1401 0.2
●
1/2”
VZ 1402 0.5
●
1/2”
VZ 1403
1
●
1/2”
VZ 1404
2
●
3/4”
VZ 1451
4
●
globe
●
●
●
●
●
construction, linear movement (2...120°C max water)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
VZ Screwed, bronze, hot/chilled water,
1”
VZ 2501
8
●
11/4”
VZ 2551 12
●
11/2”
VZ 2601 20
●
2”
VZ 2651 32
●
globe
●
●
●
●
construction, linear movement (2...200°C max water)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
VZF Flanged, table 16/11, BS4505, cast
65mm VZF 1727 63
●
80mm VZF 1777 80
●
100mm VZF 1852 125
●
125mm VZF 1902 200
●
150mm VZF 1954 315
●
iron, globe construction, linear movement (2...200°C max water)
●
X
●
X
●
●
●
●
●
●
X
●
X
●
●
●
●
●
●
X
●
X
●
●
●
●
●
●
X
●
X
●
X
X
X
X
●
X
●
X
●
X
X
X
X
Product Selection - page no.
48
● Direct coupling
X NOT compatible
48
48
48
48
48
48
48
* Self stroking, superfast/low hysteresis
MZ, MZF Valves
ALX
1201
230V
24V
Types
std
std
Force (N)
538
538
Input Control Signal
Size
Spec. no.
ALX
1251
ALi
1576
1577
24V 0..10V 0..10V 0..10V
24V 24V
24V
short std short s.fast*
311
ALE
1302
538
ALE
1352
511
700
ALi
1676
1677
0..10V
24V
s.fast*
700
0..10V
24V
spring spring spring
return return return
311
311
311
24V
Input Control Signal
Types
Force (N)
Size
CvS
MZ Screwed, bronze globe construction, linear moving spindle (2...200°C max water)
1/2”
MZ 3402 2.5
●
●
●
●
●
●
●
●
3/4”
MZ 3452
4
●
●
●
●
●
●
●
●
1”
MZ 3501
8
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
11/4” MZ 3551 12
●
●
●
●
●
●
●
●
11/2” MZ 3601 20
2”
MZ 3651 32
●
●
●
●
●
●
●
●
●
●
●
●
●
●
48
48
48
48
48
48
48
48
48
Spec. no.
AVUX AVUM AVUE AVUE
4202 4601 4304 4354
24V 230V 0...10V 0..10V
–
–
DA
RA
220
220
220
220
X NOT compatible
●
●
●
●
●
●
VZX Screwed BSP, bronze globe
1/2”
VZX 4404
3/4”
VZX 4451
1”
VZX 4501
11/4”
VZX 4551
11/2”
VZX 4601
2”
VZX 4651
48
Size
ALX
1201
230V
24V
Types
std
std
Force (N)
538
538
ALX
1251
ALi
1576
1577
24V 0-10V 0-10V 0-10V
24V 24V
24V
short std short s.fast*
311
ALE
1302
538
ALE
1352
511
700
ALi
1676
1677
0-10V
24V
s.fast*
SETH
565-1-601 to
565-1-610
Item
Spec. no.
Range
Current Equipment
574-2-701
45...65% rh
● ●
Climatronic CZH 562-3-501
562-3-502
30...55% rh
45...70% rh
● ●
● ●
Keyboard
20...80%
20...90%
20...90%
20...90%
20...90%
20...90%
20...90%
20...90%
● ●
●
●
●
●
●
●
●
Monotronic ZH
KZH 4551
MMC 2401
MMC 2402
MMC 2403
MMC 2451
MMC 2452
MMC 2453
MMC 3701
rh
rh
rh
rh
rh
rh
rh
rh
Notes
700
230V
46
46
46
Spec.
no.
No. of
steps
Switch
rating
MC and MD MC 1201
MC 1202
MC 1203
MD 3201
MD 3226
6
9
12
5
10
6 Amp
6 Amp
6 Amp
20 Amp
20 Amp
46
TSU
569-2-402
2
Notes
●
●
●
●
●
583-1-551
Size
linear moving spindle (2...200°C max
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
–
●
–
●
●
–
●
–
●
●
–
●
–
●
●
steam)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Spec. no.
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
MEU 3-port unit
1/2”
1/2”
1/2”
3/4”
3/4”
valves (2...120°C max water)
MEU 4422
0.63
●
MEU 4423
1
●
MEU 4425
2
●
MEU 4426
4
●
MEU 4427
6
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
46
46
46
46
46
46
Product Selection - page no.
Product Selection - page no.
48
48
48
48
48
48
48
48
48
valves (2...120°C max water)
FEU 6414
0.63
●
FEU 6415
1
●
FEU 6416
2
●
FEU 5626
4
●
FEU 5627
5.6
●
FEU 6451
0.63
●
FEU 6452
1
●
FEU 6454
2
●
● Direct coupling
* Self stroking, superfast/low hysteresis
54
Spec. no.
6
Control
X NOT compatible
46
Zonemaster 569-1-201 10...40°C
CZU
569-2-201 10...40°C
569-3-201 10...40°C
569-1-202 10...40°C
569-2-202 10...40°C
569-3-202 10...40°C
569-1-203 10...40°C
569-2-203 10...40°C
569-3-203 10...40°C
NSU
Binary
●
CXOC
562-3-713
562-3-715
●
CD
567-1-201
567-2-201
●
●
CSC
561-2-701
561-2-702
561-2-703
561-2-726
561-2-727
561-2-776
561-2-777
●
●
●
Output
24V
24V
24V
24V
24V
24V
24V
24V
24V
● ●
Current Equipment
●
●
●
●
●
●
●
●
●
The IACs need to be
engineered
●
CZV
569-2-501 0.4...10
m/s
●
TSU
569-2-402
0...10Vdc
●
●
Actuator to be replaced
with XRM 3201.
●
●
●
●
No equivalent available
SXC
565-1-217
565-1-218
565-1-219
565-1-220
565-1-223
565-1-224
4201
4301
4202
4302
Used with the C4X
and C5X system.
Change complete
system to CSC.
* If original actuator is to
be used and it is a K or P
series than a transformer
must be supplied with the
compensator.
● ●
● ●
● ●
●
573-1-201
573-1-251
573-1-276
CSC
CSC
CSC
CSC
If original actuator is
ALXS then a
separate transformer
is required.
No direct replacement
Use MMC and
associated
detectors/sensors.
See above remark*.
Replace C7W and C7P
detectors/sensors.
● ●
● ●
●
No direct replacement
Refer to Customer Care
Centre or your local
sales engineer.
See above remark*.
Replace
detectors/sensors.
●
●
●
●
●
●
●
CMC
CMC 3803
No direct replacement
CSMC
CSMC 3804
CSMC 3805
No direct replacement
Optimiser Controllers
Notes
Item
Remarks
●
●
569-1-501 0...250mm 0.5 +
569-2-501 H2O
10Vdc
●
●
If original actuator is to
be used and it is a K or P
series then a transformer
must be supplied with
CSC compensator.
Product Selection - page no. 35 35
The CZU 4201 must be
installed adjacent to
the fan coil unit with a
DRT 3451 if temp
adjustment from the
room is required.
CZP
●
●
RR
XC10
C7
CSC
38 39 36
569-1-401 0...10V dc
569-2-401 to reset CZU
Product Selection - page no.
562-3-704
562-3-707
562-3-710
565-1-221
565-1-222
565-1-225
Zonemaster & Temperature Controllers
Item
Mark 5 CSC's can use
existing sensors.
Remarks
Note: The FLS requires
a 0...10 volt dc control
signal.
●
5 Amp
CvS
valves (2...120°C max water)
VEU 4414
0.63
●
VEU 4415
1
●
VEU 4416
1.6
●
VEU 4626
4
●
FEU 4-port unit
1/2”
1/2”
1/2”
3/4”
3/4”
15mm
15mm
15mm
48
AVUX AVUM AVUE AVUE AVE
AVE
3202 3601 3304 3354 0001 0002
24V 230V 0..10V 0..10V 0..10V 0..10V
–
–
DA
RA
DA
RA
220
220
220
220
105
105
VEU 2-port unit
1/2”
1/2”
1/2”
3/4”
MJF Flanged, table 16/11, BS 4504, cast iron globe construction, linear movement (2...200°C max water)
15mm MJF 3426 2.5
●
●
●
●
●
●
●
●
●
●
15mm MJF 3427 4
●
●
●
●
●
●
●
●
●
●
20mm MJF 3476 6.3
●
●
●
●
●
●
●
●
●
●
25mm MJF 3526 10
●
●
●
●
●
●
●
●
●
●
32mm MJF 3576 16
●
●
X
●
X
●
●
●
●
●
40mm MJF 3626 25
●
●
X
●
X
●
●
●
●
●
50mm MJF 3676 40
●
●
X
●
X
●
●
●
●
●
X NOT compatible
AVU
2201
24V
–
105
●
Calibrator Box
CC
C4
C4X
C5
C5X
There is no direct
replacement. However,
if the controls are
being replaced and
they are installed
within a panel then the
FLS may be considered.
Remarks
562-3-702
562-3-706
562-3-711
Compensators
C6
572-1-276
572-1-376
Current Equipment
Notes
Alternatively use MMC 4701
and associated detectors/sensors.
Response
Regulator
KZH and KMC
terminals are
different
X NOT compatible
Input Control Signal
Types
Force (N)
0-10V
24V
spring spring spring
return return return
311
311
311
If KMC/MMC is
supplied then
actuators to be
changed to 0...10V
signal
36 37
Product Selection - page no.
24V
Remarks
Detectors/
sensors to
be changed
Current Equipment
● ●
COC
Humidity Controllers
Item
construction, linear movement (2...120°C max water)
2
●
●
●
●
4
●
●
●
●
8
●
●
●
●
12
●
●
●
●
20
●
●
●
●
32
●
●
●
●
ALMS ALXS ALES
1601/ 1201/ 1302/
1651 1251 1352
CvS
VSF Flanged, table 16/11, BS 4504, cast iron,
15mm VSF 2426 0.63
●
●
15mm VSF 2427 1
●
●
15mm VSF 2428 1.6
●
●
15mm VSF 2429 2.5
●
●
15mm VSF 2430 4
●
●
20mm VSF 1476 6.3
●
●
25mm VSF 1526 10
●
●
32mm VSF 1576 16
●
●
40mm VSF 1626 25
●
●
50mm VSF 1676 40
●
●
● Direct coupling
565-1-501
VEU, MEU, FEU Valves
ALM
1601
Spec. no.
SEH
FBS
VSF, MJF Valves
565-1-404 to
565-1-455
Spec. no.
Compensators
CXC
562-3-701
Refer to Satchwell with full
specification of obsolete
control and temperature
range controller or contact
your local sales engineer.
Step Controllers
* Self stroking, superfast/low hysteresis
● Direct coupling
Input Control Signal
48
Duotronic 565
SET
CvS
Product Selection - page no.
● Direct coupling
576-2-201 to
576-2-458
Item
No single direct replacement
for these controls however a
combination of keyboard or
climatronic may be suitable.
Product Selection - page no.
MZX Screwed BSP, bronze globe construction, linear movement (2...120°C max water)
1/2”
MZX 4402
2.5
●
●
●
●
3/4”
MZX 4452
4
●
●
●
●
1”
MZX 4501
8
●
●
●
●
11/4”
MZX 4551
12
●
●
●
●
11/2”
MZX 4601
20
●
●
●
●
2”
MZX 4651
32
●
●
●
●
MZF Flanged, table 16/11, BS 4504, cast iron globe construction, linear movement (2...200°C max water)
65mm MZF 3729 63
●
●
X
●
X
●
●
●
●
●
80mm MZF 3779 80
●
●
X
●
X
●
●
●
●
●
100mm MZF 3854 125
●
●
X
●
X
●
●
●
●
●
125mm MZF 3904 200
●
●
X
●
X
●
X
X
X
X
150mm MZF 3958 315
●
●
X
●
X
●
X
X
X
X
Product Selection - page no.
Duotronic E
MZX, VZX Valves
ALMS ALXS ALES
1601/ 1201/ 1302/
1651 1251 1352
230V
EC1-2 to
EC26-2
IAC 420
ALM
1601
311
CvS
48
Duotronic EC
ALMS ALXS ALES
1601/ 1201/ 1302/
1651 1251 1352
Spec. no. Current Equipment Notes
SVT 4201
Product Selection - page no.
● Direct coupling
230V
Input Control Signal
ALX
1251
Remarks
CSC 5352
15
ALX
1201
Compensator Controllers
Notes
CSC 5252
2
ALM
1601
Current Equipment
MMC 4701
2
ARX ARE
2253 2354
24V 0...10V
Spec. no.
FLS 1502
Spec. no.
ARX ARE ARM
2203 2304 2657
24V 0...10V 230V
adj span
24V
15
15
8
Item
KMC 3201
Size
ARM
2607
230V
Humidity & Temperature Controllers
IAC 420
Types
Torque (Nm)
XRM
3201
24V
OBSOLETE PRODUCTS
CZU 4201
Input Control Signal
RM
3601
230V
VZ, VZF Valves
Satchwell Controllers
IAC 600
MB, MBF Valves with linkage kits
Satchwell Valves & Actuators
Optimisers
SST 1801
565-1-801
SST 1802
SST 1803
SST 1804
565-1-802
565-1-803
565-1-804
SST 1805
565-1-805
SST 1806
SST 1871
565-1-806
565-1-871
ESS 2202
SMT 1201
588-2-202
587-1-201
● ●
No direct replacement
No direct replacement
● ●
CMC 3803 561-3-803
CSMC 3804 561-3-804
CSMC 3805 561-3-805
Use relays to cover
the 5A rating
37 38
Product Selection - page no. 35 35
55
The detector/sensor
is supplied with the
SVT but it has no
outside detector.
● ●
Optimiser/Compensators
CMC 1801 561-1-801
CMC 1803 561-1-803
CMC 1826 561-1-826
10Vdc and
15Vdc fixed
Remarks
SVT 4251
PRODUCT COMPATIBILITY
No direct replacement
No direct replacement
Refer to Customer
Care Centre or your
local sales engineer.
Temperature Controllers
Adjustable scale
Location
● ● ●
●
●
Climatronic
562-3-601
562-3-602
562-3-603
562-3-604
562-4-601
562-4-604
CXT
–5...40°C
20...70°C
35...120°C
35...120°C
0...50°C
30...120°C
Climatronic
566-1-601
566-1-602
566-1-603
566-1-651
AXT Controller-motor
5...40°C
●
20...65°C
35...120°C
5...40°C
●
Climatronic
566-1-301
566-1-302
566-1-303
566-1-351
566-1-352
AZT Controller-motor
–5...40°C
–5...40°C
35...120°C
–5...40°C
–5...40°C
Climatronic
562-3-301
562-3-302
562-3-303
562-4-302
562-4-303
CZT
–5...40°C
–5...40°C
35...120°C
–5...40°C
30...120°C
●
●
●
●
●
●
●
●
●
AZT Controller-motor
10...35°C
10...35°C
10...35°C
10...35°C
10...35°C
CXT 5605 can use
existing sensors
Controller-actuator AET, AEST
568-1-201
10...40°C
568-1-202
10...40°C
568-1-301
10...40°C
568-1-302
10...40°C
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
These controls are
controller/actuator
combined therefore a
replacement actuator
will be required.
583-1-801
583-1-601
583-1-001
583-1-401
583-1-251
KET 4201
5...50°C
0...10Vdc
5...50°C
0...10Vdc
331-3-601
331-3-602
DRH
331-3-401
●
Actuators and
detectors/sensors to
be replaced.
If valve fitted check
suitable actuator
replacement.
Direct replacement
ABC = 123
●
331-4-401
7722
DRTH
7723
DDH
331-3-451
●
DDH 3451 uses 15Vdc
power supply
DDTH 7551 requires
24Vac power supply.
●
331-7-451
Fixing is the same but enclosure size
is slightly different.
●
336-1-204
No direct
equivalent
available
DW 1204
Refer to Satchwell or
contact your local
sales engineer.
Detectors/sensors
to be changed if
MMC being installed.
DR 3252
DRT
215-1-601
DDE
331-3-301
DDTE 1601
DWTE 1201
DWTE 1202
Product Selection - page no.
41
41
Adjustable scale
Location
Spec. no.
Range
CXR 5805 can use
existing sensors
41
300mm
–
125mm
200mm
165mm
–
–
–
–
Product Selection - page no.
Item
Spec. no.
Range
40
DDU
1803
none
duct
40
DDT
0001
none
duct
DWT
0001
none
imm.
DWT
0002
none
imm.
DST
0001
none
clamp
DOT
0002
none
outs.
DOS
0001
none
outs.
MMC 4701 can use
existing sensors
Current Equipment
No equivalent
replacements
Spec. no.
Selectable range
EPT 7301
0...10Vdc, 0...5Vdc,
4...20mA
●
Product Selection - page no.
45
Item/
Voltage Input
Spec. no.
Current Equipment
●
●
41
41
42
42
42
43
AE
568-1-501
568-1-502
568-1-503
568-1-504
24V
24V
24V
24V
0...10V
0...10V
0...10V
0...10V
● ● ●
● ● ●
●
●
AEH
568-1-552
24V
0...10V
● ● ●
AES
568-1-601
568-1-602
24V
24V
0...10V
0...10V
AEHS
568-1-651
24V
0...10V
Item
43
Outside Pilot
CP
No equivalent
available
Change complete
system to CSC with
detectors/sensors.
If actuator is XKM or
XPM then a
transformer must
be supplied.
ET
ZW
No equivalent
available
325-1-201
325-1-251
325-1-301
323-2-201
323-2-204
323-2-207
No equivalent
available
ZHO 331-2-701
EO
326-1-303
DP
334-1-201
Limiting Detectors
LO
137-1-452
●
●
Product Selection - page no. 35 36 36 36 37
No equivalent
available
327-1-202
56
5...60°C
LR
167-1-253
20...90°C
LZS
315-1-201
10...40°C
Remarks
When selecting
the ‘AL’ range of
actuators check
size of valve - you
may be able to
supply the short
stroke actuator.
● ●
● ●
Other combinations available
consult Satchwell.
● ●
● ●
When replacement actuators are
No direct
replacement required please
check suitability
(ie) shoe or lift
and lay valves.
‘P, K, & M’ Series Actuators – 230V/24V
●
●
No equivalent
available
C7W 323-2-501
●
●
●
●
●
●
●
Notes
●
CRX
CO
EPT
7401
yes
panel
Product Selection - page no. 47 48 48 48 48 48 48
●*
●*
Remarks
Detectors
C7P 326-2-501
Refer to Satchwell or
contact your local
sales engineer.
41
●
●
Notes
Regulator Thermostats
CR
●
●
41
Transducers
Spec
no.
Volt.
Pot.
Current Equipment
Change system.
41
Stem/pocket
DDT 1701 –5...+100°C
DDU 1801 –5...+40°C
DWT 1701 –10...+120°C
DWT 1702 –10...+120°C
DWT 1801 –10...+120°C
DST 1601
5...120°C
DOT 2301 –40...+40°C
DOT 0001 –40...+55°C
DOS 2501
–
Controller/actuator
combined therefore
actuator to be
replaced.
Product Selection - page no.
339-1-304
DR 3251
Detectors/sensors
to be changed if
adjustable type.
Also if MMC, KMC
is installed.
●
‘AE’ Series Actuators – 24V
DW 1202
Controller/actuator
combined therefore
actuator to be
replaced.
●
331-3-551
DD 1403
Detectors/sensors
to be changed if
MMC, KMC is
being installed.
–125...+250pa
–3750...+7500
Requires remounting
DD 1401
DWS
Selectable range
DDP 4201
DDP 4203
Change terminal nos.
●
DO 2202
CZT 5305 can use
existing sensors
Spec. no.
LCD display
Location
DRTH
DDH
No equivalent
replacement
Micro Management
MMC 2401 –40...140°C
MMC 2402 –40...140°C
MMC 2403 –40...140°C
MMC 2451 –40...150°C
MMC 2452 –40...150°C
MMC 2453 –40...150°C
MMC 3701 –40...150°C
Keyboard
KZT 4351
DRH
Change complete
system to KMC
or MMC.
No direct
equivalent
available
DDTH 331-7-551
Climatronic CZS
562-3-201
MPD 1801
COE 1601
FSS 1001
FSS 1401
FSC 1251
331-3-702
331-3-704
DDH
Climatronic AZS Controller-motor
485-1-201
563-1-201
583-1-201
Remarks
Item/
Spec. no.
Change complete system
to CSC or MMC with
detectors/sensors. If actuator
is XKM or XPM then a
transformer must be supplied.
Change control system
dependant upon
existing controls.
Refer to Satchwell with
full specification
number of obsolete
control and
temperature range of
controller or contact
your local sales
engineer.
'M' Series Actuators
458-1-201 230V
458-1-301 230V
No
No
'P' Series Actuators
PM
453-1-203 230V
No
SPM
–
230V
EPM
31
24V 1000Ω
ZPM
31
24V 135Ω
XPM
31
24V
No
'K' Series Actuators
KM
454-2-202 230V
No
Current Equipment
Notes
Remarks
●
●
● ●
N.D.R.
N.D.R.
●
● ●
Check valve type
if replacement
actuator can be
fitted without
valve change
as well.
SKM
455-2-202 230V
455-2-252 230V
EKM
475-2-401
24V 1000Ω
SEKM 484-2-401
24V 1000Ω
When
replacement
actuators are
required please
check suitability
No direct
(ie) shoe or lift
replacement and lay valves.
ZKM 475-2-201
SZKM 484-2-201
24V 135Ω
24V 135Ω
No direct
replacement
XKM 474-2-201
SXKM 483-2-201
24V
24V
Product Selection - page no.
Pot.
●
●
●
No
No
●
●
Current Equipment
AM
456-2-201 230V
456-2-401 230V
456-2-402 230V
No
No
No
●
●
●
●
AMH
457-2-451 230V
No
●
●
AMS
457-2-201 230V
No
457-2-202 230V
No
AMHS
457-2-251 230V
No
Notes
ARM not
compatible
with CMC
3803
●
● ●
● ●
● ●
47 47 48 48 48 48 48 48 48 N.D.R.= No direct replacement
No equivalent
available
57
Remarks
When selecting
the ‘AL’ range of
actuators check
size of valve you may be able
to supply the
short stroke
actuator.
No direct
replacement
When
replacement
actuators are
No direct
required please
replacement check suitability
(ie) shoe or lift
and lay valves.
AZM
476-1-401
476-1-402
476-1-451
476-1-801
476-1-851
24V
24V
24V
24V
24V
AZ
476-2-401
476-2-451
24V 135Ω
24V 135Ω
AZH
476-2-851
24V 135Ω
AZS
476-2-401
476-2-451
24V 135Ω
24V 135Ω
AXM
476-1-201
476-1-202
476-1-251
24V
24V
24V
No
No
No
AX
476-2-701
476-2-751
476-2-201
476-2-251
24V
24V
24V
24V
No
No
No
No
●
●
●
●
●
●
AXH
476-2-276
476-2-776
24V
24V
No
No
●
●
● ●
● ●
AXS
485-2-201
485-2-251
24V
24V
No
No
AXHS
485-2-276
24V
No
ALM
477-1-626 230V
477-1-651 230V
No
No
ALX
477-1-226
24V
No
ALE
477-1-327
477-1-376
24V
24V
No
No
135Ω
135Ω
135Ω
135Ω
135Ω
No direct
replacement
No direct
replacement
● ●
● ●
●
When selecting
the ‘AL’ range of
actuators check
size of valve you may be able
to supply the
short stroke
actuator.
●
●
●
●
●
●
●
● ●
● ●
No direct
replacement
●
●
●
● ●
● ●
Product Select. - page no. 47 47 48 48 48 48 48 48 48 47 47 48 48
Replace valve
actuator with MB
/ARM linkage kit.
No
No
No
Volt.
DDP DDP DDP DDP
5601 5610 6601 6610
no
no
yes
yes
duct duct panel panel
LCD display
Location
Notes
DRTH 331-7-501
Detectors/sensors
to be changed if
MMC, KMC is
being installed
DRTH
7XXX
8XXX
none
room
* note: DWA 0001 is required
Monotronic Balancing Relay (ZC)
581-2-201
Keyboard
CMT 1201
FMS 1201
331-2-601
DDH
DRH
ARE actuator +
linkage kit
●
●
●
●
●
DRH
7XXX
8XXX
none
room
Spec. no.
ZHT
DD
● ● ●
● ● ●
●
●
●
DDTH
7XXX
8XXX
none
duct
Detectors
EH
331-1-401
● ● ●
● ● ●
●
● ● ●
● ● ●
●
Climatronic CXR
562-1-801
562-2-801
562-3-801
562-4-831
10...40°C
562-4-801
10...40°C
Actuators must be
replaced with a 0...10V
type when used with
CZT/KMC or
multi-stage MMC’s.
●
●
CD
567-2-401
Controller-motor AXR
566-1-801
Detectors/sensors
to be replaced
‘A’ Series Actuators – 230V/24V
Current Equipment
ARM 2607
ARX 2203
ALM 1601
ALX 1201
ALX 1251
ALMS 1601
ALMS 1651
ALXS 1201
ALXS 1251
●
●
DDH
7XXX
8XXX
none
duct
OBSOLETE PRODUCTS
Pressure Sensors
Current Equipment
MMC 4701
KMC 3201
CZT 5305
Remarks
Item
●
6...40°C
40...110°C
Monotronic
574-2-551
6...40°C
574-2-552
20...95°C
574-2-553
45...125°C
Climatronic
566-3-001
566-3-302
566-3-304
566-3-352
566-3-354
Notes
Sensors, Transducer and Valves
ARE 2304
ALE 1302
ALE 1352
ALES 1302
ALES 1352
ALi 1576
ALi 1577
Intronic X
575-1-201
575-1-202
Detectors/sensors
Current Equipment
CXT 5605
Range
CXR 5805
Item/
Spec. no.
Satchwell Controllers & Detectors/Sensors
ARM 2607
ARX 2203
ALM 1601
ALX 1201
ALX 1251
ALMS 1601
ALMS 1651
ALXS 1201
ALXS 1251
RM 3601
XRM 3201
ALi 1576
ALi 1577
OBSOLETE PRODUCTS
Check VA
rating.
Check if
feedback
signal is
required.
24V
”
4 Nm
8 Nm
ZV Actuators
2-port, BSP parallel
1/2”
ZV 1201
3/4”
ZV 1202
●
●
No direct replacement
1”
●
No direct replacement
●
Product Selection - page no.
47 47 47
‘RMV, RXV, REV’ Series Actuators – 230V/24V
Current Equipment
RMV 7653 230V 12 Nm
RMV 7653
”
”
RXV 7253
RXV 7253
24V
”
”
”
REV 7353
24V
”
Notes
Remarks
● ●
● ●
●
●
Volt.
Pot.
47 47
Current Equipment
●
●
No
No
ERM
472-1-401
472-2-401
24V 1000Ω
24V 1000Ω
ZRM
472-1-201
472-2-201
472-1-202
472-2-202
472-1-203
472-2-203
472-3-201
472-3-202
472-3-203
24V
24V
24V
24V
24V
24V
24V
24V
24V
'AR' Series Actuators
ARM 473-7-601
473-1-602
473-1-601
ARM 2601
Notes
ARX
ARE
●
●
Remarks
When
replacement
No direct
actuators are
replacement required please
check suitability
No direct
replacement (ie) shoe or lift
and lay valves.
135Ω
135Ω
135Ω
135Ω
135Ω
135Ω
135Ω
135Ω
135Ω
No
No
No
No
●
●
●
●
ARM 2605 230V
ARM 2651 230V
No
No
●
473-7-201
473-1-202
473-1-201
ARX 2201
ARX 2251
24V
24V
24V
24V
24V
No
No
No
No
No
473-7-301
473-1-302
473-7-303
473-1-301
ARE 2301
ARE 2351
24V
24V
24V
24V
24V
24V
0...10V
0...10V
0...10V
0...10V
0...10V
0...10V
●
●
●
●
●
●
ZV 1303
7.6
No equivalent
available
●
●
●
●
●
No equivalent
available
3-port, compression fitting
15mm
ZV 1304
6
22mm
ZV 1305
7
28mm
ZV 1306 7.6
No equivalent
available
FEU
MK2
(4-Port)
628-2
AVUE Mk2
No
No
No
AVUE Mk1
Yes
Yes
Yes
Current Equipment
6
7
7.6
No equivalent
available
3-port, BSP parallel
1/2”
ZVX 3301
3/4”
ZVX 3302
1”
ZVX 3303
6
7
7.6
No equivalent
available
●
49 49 49 49 49 49 49 49 49
VEU
Mk4
(2-Port)
623-4
Item
Spec no.
Voltage Signal
AVU
478-1-201
24V
No
478-2-451
24V
–
Current Equipment
Notes
FEU
Mk4
(4-Port)
628-4
FEU
Mk5
(4-Port)
628-5
VZX
MZX
(2-Port)
624-4
(3-Port)
626-4
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Yes
Yes
24V
0...10V
24V
24V
0...4V
6...10V
478-2-304
478-3-304
24V
24V
0...10V
0...10V
478-1-354
24V
0...10V
478-1-355
478-1-356
24V
24V
0...4V
6...10V
478-2-354
478-3-354
24V
24V
0...10V
0...10V
478-1-201
478-1-202
478-3-202
24V
24V
24V
–
–
–
AVUM 478-1-601
478-2-601
478-3-601
230V
230V
230V
–
–
–
AVUX
MEU
Mk4
(3-Port)
627-4
478-1-304
478-1-305
478-1-306
Product Selection - page no.
58
●
Notes
construction, linear moving spindle)
2.5
●
● ● ● ●
5.6
●
●
8
●
●
16
●
●
20
●
●
50 50 50 50 50 50
●
●
●
●
●
●
●
●
●
●
●
●
●
●
50 50 50 50 50 50 50 50 50 50
Size
Spec. no.
CvS
MV (Water)
11/4”
11/2”
2”
21/2”
3”
4”
612-1-551
612-1-601
612-1-651
612-1-701
612-1-751
612-1-826
68
100
180
270
470
620
Current Equipment
Remarks
Notes
●
●
●
VV Screwed, BSP parallel female, butterfly on/off, control not tight shut off (2...120°C
2”
VV 3651 180
●
No direct
VV 3701 270
●
replacement
21/2”
3”
VV 3751 470
●
4”
VV 3826 620
●
Product Selection - page no.
Remarks
Change actuator and linkage.
For 11/4” & 11/2” use MB valve
and blank off third port.
max water)
2” use MB valve, for 21/2”...4” use MBF
and blank off third port. CVS value
is different and must be checked.
50 50 50 50 50 50 50
2-port Valves continued next page.
See notes on
VEU, MEU, FEU
No
replacement and valve/
actuators
compatibility
below before
No
replacement specifying
replacement
actuators.
●
●
●
These valves are normally
open i.e. lift to open when
new valve is fitted to
terminals 1 & 2 the
actuator must be reversed
●
50 50 50 50 50 50 50 50
Remarks
Use MB valves blanking
plug in third port with
RM or ARM actuator
linkage kit
2-port Valves
Item
ZVX Actuators
2-port, BSP parallel
1/2”
ZVX 3201
3/4”
ZVX 3202
1”
ZVX 3203
AVUE
(RA)
●
47 47 47 47 47 47
MEU
Mk2
(3-Port)
627-2
CvS
Product Selection - page no.
3-port, compression fitting
15mm
ZV 1304
6
22mm
ZV 1305
7
28mm
ZV 1306 7.6
AVUE
(DA)
●
VEU
Mk2
(2-Port)
623-2
Spec. no.
VMF (Cast iron, globe construction, linear moving spindle, hot water or steam)
VMF 3430
0.25
VMF 3431
1
VMF 3432
2.5
VMF 3433
4
VMF 3477
6.3
VMF 3527
10
VMF 3577
16
VMF 3627
25
VMF 3677
40
No equivalent
available
6
7
Product Selection - page no.
Valve/actuator compatibility
Actuator
No equivalent
available
3-port, compression fitting
22mm ZVX 3401 7
Not compatible
with CSMC controller
●
Product Selection - page no.
2-port, compression fitting
15mm
ZV 1204
6
22mm
ZV 1205
7
28mm
ZV 1206 7.6
‘AVU & AVUE’ Valve/actuators – 230V/24V 0...10Vdc
230V
230V
230V
230V
Size
VM (Cast iron, globe construction, linear moving spindle, hot water or steam)
VM 1405
0.2
●
VM 1406
0.5
●
VM 1407
1.2
●
VM 1408
2.5
VM 1452
5
VM 1502
8
VM 1552
12
VM 1602
20
AVU 2201
AVUE 4304
AVUE 4354
AVUX 4202
AVUM 4601
'R' Series Actuators
RM
471-1-601 230V
471-2-601 230V
Item
VG (Screwed, bronze body, globe
1/2”
VG 1401
3/4”
VG 1451
1”
VG 1501
VG 1551
11/4”
11/2”
VG 1601
No equivalent
available
No equivalent
available
1”
ARM 2607
ARM 2657
ARX 2203
ARX 2253
ARE 2304
ARE 2354
RM 3601
Spec
no.
7.6
2-port, BSP parallel with auxiliary switch
1/2”
ZV 1251
6
3/4”
ZV 1252
7
1”
ZV 1253 7.6
– 8 Nm for MBF
– for MB valves
‘AR & R’ Series Actuators – 230V/24V
Item
ZV 1203
3-port, BSP parallel
1/2”
ZV 1301
3/4”
ZV 1302
– 8 Nm for MBF
– for MB valves
●
Product Selection - page no. 47 47 47 47 47
Remarks
●
●
6
7
2-port, compression fitting with auxiliary switch
15mm
ZV 1254
6
22mm
ZV 1255
7
28mm
ZV 1256 7.6
XRM 3201
RM 3601
Volt. Torque
ARM 2656
ARM 2657
ARX 2252
ARX 2253
ARE 2352
Item
2-Port Valves
Notes
2426
2427
2428
2429
2430
1476
1526
1576
1626
1676
RE 7352
RE 7351
Current Equipment
VSF
VSF
VSF
VSF
VSF
VSF
VSF
VSF
VSF
VSF
4 Nm
8 Nm
CvS
1401
1402
1403
1404
1451
2501
2551
2601
24V
”
Spec. no.
VZ
VZ
VZ
VZ
VZ
VZ
VZ
VZ
RX 7252
RX 7251
Size
MBF 4732
MBF 4782
MBF 4857
4 Nm
8 Nm
Item
Remarks
MB 1552
MB 1602
MB 1652
230V
”
‘ZV & ZVX’ Valve/actuators – 230V/24V
Notes
OBSOLETE PRODUCTS
ZVX 4201
ZVX 4202
ZVX 4203
ZVX 4301
ZVX 4302
ZVX 4303
ZVX 4401
ZY 1306
ZY 1206
RM 7652
RM 7651
Current Equipment
ARM 2656
ARX 2252
ARE 2352
Volt. Torque
Satchwell Valves
1402
1452
1502
1552
1602
1652
‘RM, RX, RE’ Series Actuators – 230V/24V
Item
Satchwell Actuators & Valve/Actuators
MB
MB
MB
MB
MB
MB
OBSOLETE PRODUCTS
●
No
replacement
●
●
●
●
●
●
●
●
46 46 46 46 46
59
OBSOLETE PRODUCTS
Satchwell Valves
3-port Valves
MA (Steam and high pressure hot water)
666-2-577
15
11/4”
666-2-627
15
11/2”
2”
666-2-677
39
●
No direct
replacements
●
●
● ● ● ● ●
● ● ● ●
● ● ●
641-1-401
641-1-451
641-1-501
641-1-551
641-1-601
2.7
5.6
8.2
15
18
● ● ● ● ●
●
VM (Water)
1/2”
3/4”
1”
11/4”
1
1 /2”
641-1-401
641-1-451
641-1-501
641-1-551
641-1-601
2.7
5.6
8.2
15
18
● ● ● ● ●
● ● ●
● ● ● ●
● ● ●
● ●
VZ (Screwed, cast
1”
11/4”
11/2”
2”
iron, globe construction, linear moving spindle (2 to 130°C max water)
VZ 2502
8
●
VZ 2552
12
●
VZ 2602
20
●
VZ 2652
32
●
● ● ● ● ●
●
●
633-1-203
633-1-253
633-1-303
633-1-353
633-1-403
633-1-453
633-1-503
633-1-533
633-1-603
633-1-653
633-1-727
633-1-777
0.18
0.33
0.68
1.2
2.2
5.6
10
15
22
39
56
82
●
●
●
●
●
●
MF (Water)
1/8”
3/16”
1/4”
3/8”
1/2”
3/4”
1”
11/4”
11/2”
2”
21/2”
3”
633-1-201
633-1-251
633-1-301
633-1-351
633-1-401
633-1-451
633-1-501
633-1-551
633-1-601
633-1-651
633-1-726
633-1-776
0.18
0.33
0.68
1.2
2.2
5.6
10
15
22
39
56
82
●
●
●
●
●
MS (Steam)
3/4”
1”
11/2”
2”
631-1-453
631-1-503
631-1-603
631-1-677
12
18
33
68
●
MS (Water)
3/4”
1”
11/2”
2”
631-1-451
631-1-501
631-1-601
631-1-676
12
18
33
68
● ● ● ● ●
● ● ● ●
● ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
● ● ● ● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ●
● ●
MM (Water)
1/2”
3/4”
654-1-401
654-1-451
2.7
5.6
MZ Screwed, cast
1”
11/4”
11/2”
2”
3729
3779
3854
3904
3958
●
MZF
MZF
MZF
MZF
MZF
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
3402
3452
3501
3551
3601
3651
MY
MY
MY
MY
MY
MY
MY
MY
MZ
MZ
MZ
MZ
MZ
MZ
MY (Water)
3/4”
1”
11/4”
11/2”
2”
21/2”
3”
4”
●
●
Change actuator.
●
●
●
●
Check application of
valve and flow rate
when replacing an MT
with a MZ valve.
●
●
●
●
●
●
●
●
●
●
●
●
●
Actuator to be changed.
●
●
●
●
Check flow rate
before selecting
replacement valve.
●
●
●
●
●
●
●
●
●
●
●
●
Actuator to be changed.
●
iron, globe construction, linear moving spindle
MZ 3502
8
MZ 3552
12
MZ 3602
20
MZ 3652
32
50 50 50 50 50 50
●
●
●
●
50 50 50
51 51 51 51 51 51
51 51 51 51 51
●
●
●
●
VEU, MEU, FEU Valves
●
Item
Size
Spec. no.
CvS
Current Equipment
Notes
Remarks
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Check Cv rating duty
and absolute pressure
Actuator must be replaced
● ● ● ● ●
● ● ● ● ●
● ● ●
● ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
● ● ● ● ●
● ● ● ●
● ●
●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ●
● ●
●
●
●
●
●
●
●
●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ●
● ● ● ●
● ●
●
● ● ● ● ●
●
●
●
●
●
50 50 50 50 50 50 50 50 50
50 50 50 50 50
50 50 50 50 50 50 50 50 50 50
VEU 2-port Unit Valves (2...120°C max water)
1/2”
VEU 2414
0.63
●
1/2”
VEU 2415
1
●
1/2”
VEU 2416
1.6
●
3/4”
VEU 2626
4
●
MEU 3-port Unit
1/2”
1/2”
1/2”
3/4”
3/4”
●
●
●
●
● ● ● ● ●
● ● ● ●
● ●
●
60
Note:- All VSF valves are
flanged
●
●
●
●
●
● ● ● ●
● ● ●
● ●
●
●
●
●
●
●
MH (Steam and high pressure hot water)
3/8”
656-1-377
1.2
● ● ● ● ●
1/2”
656-1-427
2.2
● ● ● ● ●
3/4”
656-1-478
5.6
●
1”
656-1-528
10
656-1-578
15
11/4”
656-1-628
22
11/2”
2”
656-1-678
39
● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ●
● ● ● ●
● ● ●
● ●
●
●
Remarks
●
●
●
●
●
●
●
●
●
●
●
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Product Select. - page no.
●
●
●
●
●
●
●
●
●
●
●
● ● ● ●
● ● ●
● ●
●
MT
MT
MT
MT
MT
MT
MT
MT
MT
MT
Notes
Check Cv rating duty
and absolute pressure
Actuator must be replaced
Note:- All VSF valves are
flanged
6414
6415
6416
6451
6452
6454
5626
5627
MF (Steam)
1/8”
3/16”
1/4”
3/8”
1/2”
3/4”
1”
11/4”
11/2”
2”
21/2”
3”
Product Selection - page no.
Actuator to be replaced
●
iron, globe construction, linear moving spindle (steam)
644-4-426
0.25
644-4-427
1
644-4-428
2.5
644-4-429
4
644-4-476
6.3
644-4-526
10
644-4-576
16
644-4-626
25
644-4-676
40
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Check Cv rating duty
and absolute pressure
●
VJF (Flanged, cast
15mm
15mm
15mm
15mm
20mm
25mm
32mm
40mm
50mm
656-1-376
656-1-426
656-1-477
656-1-527
656-1-577
656-1-627
656-1-677
Actuator to be replaced
●
VM (Steam)
1/2”
3/4”
1”
11/4”
11/2”
MH (Water)
3/8”
1/2”
3/4”
1”
11/4”
11/2”
2”
Check Cv rating duty
and absolute pressure
●
● ●
●
MT (Water)
3/4”
1”
11/4”
11/2”
2”
21/2”
3”
4”
5”
6”
1402
1452
1502
1552
1602
1652
●
●
Current Equipment
FEU
FEU
FEU
FEU
FEU
FEU
FEU
FEU
15
22
39
56
100
150
CvS
4422
4423
4425
4626
4627
666-2-576
666-2-626
666-2-676
666-2-726
666-2-776
666-2-861
Spec. no.
MEU
MEU
MEU
MEU
MEU
56
100
150
Size
4414
4415
4416
4626
666-2-727
666-2-777
N/A
Item
VEU
VEU
VEU
VEU
21/2”
3”
4”
MA (Water)
11/4”
11/2”
2”
21/2”
3”
4”
Remarks
MB
MB
MB
MB
MB
MB
2426
2427
2428
2429
2430
1476
1526
1576
1626
1676
VZ
VZ
VZ
VZ
VZ
VZ
VZ
VZ
VZ
Notes
VSF
VSF
VSF
VSF
VSF
VSF
VSF
VSF
VSF
VSF
Current Equipment
1727
1777
1852
1902
1954
CvS
VZF
VZF
VZF
VZF
VZF
Spec. no.
1401
1402
1403
1404
1451
2501
2551
2601
2651
Size
OBSOLETE PRODUCTS
MBF 4732
MBF 4782
MBF 4857
2-Port Valves
Item
Satchwell Valves
Valves
MEU
MEU
MEU
MEU
MEU
(2...120°C max water)
2422
0.63
2423
1
2425
2
2626
4
2627
6
FEU 4-port Unit Valves (2...120°C
1/2”
FEU 2414
1/2”
FEU 2415
1/2”
FEU 2416
15mm
FEU 2451
15mm
FEU 2462
15mm
FEU 2454
3/4”
FEU 2626
3/4”
FEU 2627
1/2”
FEU 5414
1/2”
FEU 5415
1/2”
FEU 5416
15mm
FEU 5451
15mm
FEU 5452
15mm
FEU 5454
Product Selection - page no.
See notes on
valve/actuator
compatibility above
before specifying
replacement valves.
Applies to all valves.
●
●
●
●
●
max water)
0.63
1
2
0.63
1
2
4
5.6
0.63
1
2
0.63
1
2
49 49 49 49
●
This is not a direct
replacement as ports 1
and 2 have been
reversed and pipe work
modifications will have
to be carried out.
●
●
●
●
●
●
●
●
●
●
●
●
●
49 49 49 49 49
49 49 49 49 49 49 49 49
Check Cv rating duty
and absolute pressure
Actuator must be replaced
Note:- All VSF valves are
flanged
61
SATCHWELL
VALVE SIZING INFORMATION
SATCHWELL
VALVE SIZING INFORMATION
CVs Values
40
25
16
10
6.3
4.0
2.0
2.5
0.5
0.2
0.25
2
3
1
0.8
0.6
0.5
0.4
0.3
0
3
0
10 0
9 0
8 0
7
0
1. .9
0 .8
0 .7
0 .6
0
Water Flow (l/s)
0.
60
50
40
30
5
0.
20
4
0
.3
0.
10
2
0.2
1
0.
26
0.6
0.5
0.4
0.2
20
0.1
0.08
0.06
0.05
0.04
0.3
26
00
20
10
9
00
8
0.03
7
0.1
0.08
0.06
0.05
0.04
0.03
(a) MZ, MZX, MZF, MJF, MEU, MB or MBF Valves
6
8
4
5
3
2
0.8
1
0.4
0.5
0.6
0.3
0.2
0.08
0.1
0.04
0.05
0.06
0.03
0.02
0.008
0.01
0.006
0.003
0.004
0.002
Valve Type
P1
2
3
Source
of heat
Load
Pump
3
2
1
3
Source
of heat
Load
P2
Pump
1
(a) MB or MBF Valves only
2
Source
of heat
P1
Load
P2
Pump
(a) MB or MBF Valves only
62
For full details see Data Sheet
▼
VEU
DS 4.101
MEU
DS 4.101
FEU
DS 4.101
BFB
DS 4.103
VZ, VZX, VZF
DS 4.110, 4.101
VSF
DS 4.110
MB, MBF
DS 4.501
MZ, MZX, MZF
DS 4.610, 4.601
MJF
DS 4.610
ra)
)
Pa
(k
Pa
)
e
ur
(k
ss
Pr
es
su
re
re
tP
le
In
le
t
In
te
ut
e
Required flow greater
than 15 kg/h
CVs =
Q
13 (P1) 0.98
Note: The formulae take into account the 40% optimum pressure of drop automatically.
Cvs = Flow in UK gal/min to produce 1lbf/in2 pressure drop when the valve is
fully open Kvs = Cvs x 1.038.
Kvs = Flow in m2/hr to produce 1 bar pressure drop when the valve is fully open.
(a) MZ, MZX, MZF, MJF, MEU, MB or MBF Valves
1
e(b
(ab
leet
tP
Pr
ess
ssu
nInl
30,000
20,000
8000
10,000
4000
5000
6000
3000
2000
800
1000
300
400
500
600
200
80
100
40
50
60
30
20
8
10
6
P1 + P2
so
l
8
10
800
1000
2
Ab
4
5
6
3
1
ol
u
3
300
400
500
600
3
4
5
6
8
10
2
0.4
0.5
0.6
0.8
1
0.3
Pump
bs
2
200
Load
Pump
A
0.8
1
80
100
bAs
0.3
0.4
0.5
0.6
30
40
50
60
A
0.2
20
0.03
0.04
0.05
0.06
0.08
0.1
0.02
0.004
0.005
0.006
0.008
0.01
0.003
0.002
0.2
0.04
0.05
0.06
0.08
0.1
Pump
Load
0
Source
of heat
40
Load
0
Source
of heat
50
FLOW COEFFICIENTS: Cvs
Valve
Source
of heat
60
30
Required flow less
than 15 kg/h
CVs =
Q
8 (P1) 1.56
P1
1
0
50
40
ALTERNATIVE STEAM VALVE SIZING METHOD
As an alternative to the table the following formulae may be used:Q = Required flow in kg/h, P1 = Absolute inlet pressure in Bar.
CONSTANT TEMPERATURE – VARIABLE VOLUME
3
0
60
3
Steam Flow (kg/h)
Steam Flow (kg/s)
2
30
4
0.
Note:
Refer to appropriate valve
Data Sheet for maximum
allowable differential
pressure.
1 l/s = 3.6m3/h
100 kPa = 1 Bar approximately equal to 1.02 kgf/cm2 approximately equal to 14.5 lbf/in
CONSTANT VOLUME – VARIABLE TEMPERATURE
0
10 0
9 0
8 0
7
0.
Pressure Drop (bar)
Pressure Drop (kPa)
20
0.01
urer
3
0.006
0.005
0.004
0.003
0.02
00
10 00
9 00
8 00
7 0
4
0.01
0.008
r)
5
0.02
bos
olul
utet
eI
Water Flow (m3/hr)
Water Flow (l/s)
6
5
4
1 .9
0 .8
0 7
0. .6
0 5
0.
0.006
0.005
0.004
0.003
0.25
0.2
20
4
2
0.01
0.008
1
0.8
5
10
8
2
0
6
0.02
0.63
0.5
0.4
2
30
7
) a)
PaP
(k(k
pp
ro o
DDr
ree
suur
es s
Pres
0.03
3
8
Pr
0.1
0.08
0.06
0.05
0.04
1.0
10
9
6
1.6
6
5
4
CVs Values
Note:
For maximum temperatures, internal
pressures and differential pressures,
refer to Data Sheet DS 4.110.
) )
arar
(b(b
pp
ro o
DDr
ree
suur
es s
Pres
10
8
4
3.2
2.5
2.0
00
10 00
9 00
8 00
7 0
60 0
50 0
40
Pr
3
6.3
* This is only 18% of absolute inlet pressure and the
control quality will not be good until the valve has
partially closed. As with all steam valves this
compromise is necessary since the next smaller valve
would not pass the required flow.
Required flow: 900 kg/h
Absolute inlet pressure: 2.5 bar
Optimum pressure drop through valve = 40% of 2.5 = 1.0 bar
Ideal Cvs = 27
Nearest available valve has Cvs 25. This is inadequate because the maximum flow = 800 kg/h
∴ Use next larger valve which has Cvs = 40
Pressure drop through valve = 0.45 bar*
Max flow for same inlet pressure & Cvs = 1300 kg/h
20
16
12
10
8
30
20
0.2
40
32
25
60
50
40
6
5
4
0.6
0.5
0.4
0.3
100
80
60
50
40
30
80
63
100
80
10
8
1
0.8
120
200
20
Example:
200
200
600
500
400
300
100
80
60
50
40
30
2
280
1000
800
0.0003
0.0004
0.0005
0.0006
0.0008
0.001
200
0.03
280
STEAM VALVE SIZING CHART
1.0
WATER VALVE SIZING CHART
∆p (bar) =
flow (m 3/h)
Kvs
2
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
3/4”
3/4”
1”
11/4”
11/2”
2”
21/2”
3”
4”
5”
6”
15
mm
15
mm
15
mm
15
mm
15
mm
15
mm
20
mm
20
mm
25
mm
32
mm
40
mm
50
mm
65
mm
80
mm
100
mm
125
mm
150
mm
–
–
–
0.4
–
–
–
–
–
–
–
–
0.6
–
0.63
–
–
–
–
–
–
1.0
0.2
1.0
–
–
–
0.63
0.63
0.63
1.6
0.5
1.6
–
–
–
1.0
1.0
1.0
2.0
1.0
2.5
–
–
1.0
1.6
2.0
2.0
2.5
2.0
4.0
1.8
2.5
4.0
4.0
4.0
4.0
–
4.0
6.3
4.0
4.0
6.3
–
6.0
5.6
–
–
–
–
–
–
–
–
–
–
8.0
10.0
8.0
8.0
10.0
–
–
–
–
12
16
12
12
16
–
–
–
–
20
25
20
20
25
–
–
–
–
32
40
32
32
40
–
–
–
–
63
–
63
63
–
–
–
–
–
80
–
80
80
–
–
–
–
–
125
–
120
125
–
–
–
–
–
200
–
–
200
–
–
–
–
–
315
–
–
315
–
63
SUPPORTING INFORMATION
SENSOR RESISTANCE CHARTS
°C
–40
–39
–38
–37
–36
–35
–34
–33
–32
–31
–30
–29
–28
–27
–26
–25
–24
–23
–22
–21
–20
–19
–18
–17
–16
–15
–14
–13
–12
–11
–10
–9
–8
–7
–6
–5
–4
–3
–2
–1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
Ohms
DR 2253
DW 1202
DWS 1202 DD 1401
DW 1305 DD 1403
DO 2202 DW 1204 DD 1304
2317.20
2462.00
2304.00
2459.00
2290.30
2455.80
2276.20
2452.30
2261.50
2448.70
2246.30
2444.90
2230.50
2440.80
2214.30
2436.50
2197.60
2432.00
2180.40
2427.20
2162.60
2422.10
2144.50
2416.80
2125.80
2411.20
2106.70
2405.30
2087.20
2399.10
2067.20
2392.50
2046.90
2385.70
2026.10
2378.50
2005.00
2371.00
1983.60
2363.10
1961.90
2354.80
1939.90
2346.20
1917.60
2337.10
1895.10
2327.70
1872.30
2317.90
1849.40
2307.70
1826.40
2297.00
1803.20
2285.90
1780.00
2274.40
1756.20
2262.40
1733.30
2250.00
1709.90
2237.20
1686.60
2223.90
1663.30
2210.10
1640.10
2195.90
1617.00
2181.20
1594.00
2166.00
1571.20
2150.40
1548.60
2134.40
1526.20
2117.80
1504.00
2100.90
1482.00
3033.10
2083.50
1460.30
3020.60
2065.60
1438.90
3007.70
2047.30
1417.80
2994.40
2028.60
1396.90
2980.50
2009.50
1376.40
2966.30
1990.00
1356.30
2951.60
1970.10
1336.50
2936.40
1949.90
1317.00
2920.80
1929.30
1297.90
2904.70
1908.30
1279.20
2888.20
1887.00
1260.80
2871.10
1865.50
1242.80
2853.70
1843.60
1225.30
2835.80
1821.50
1208.10
2817.40
1799.10
1191.20
2798.50
1776.50
1174.80
2779.30
1753.70
1158.80
2759.50
1730.70
1143.10
2739.40
1707.50
1127.90
2718.80
1684.20
1113.00
2697.80
1660.80
1098.50
2676.40
1637.30
1084.40
2654.60
1613.80
1070.60
2632.40
1590.20
1057.20
2609.80
1566.60
1044.20
2586.80
1542.90
1031.60
2563.50
1519.30
1019.20
2539.90
1495.80
1007.30
2515.90
1472.30
995.70
2491.70
1448.90
984.40
2467.10
1425.60
973.40
2442.30
1402.50
962.80
2417.20
1379.40
952.50
2391.90
1356.60
NOTES
°C
DWT
DDT
DDU
DRT
DST
DOT
DOS
9711.43
9692.31
9672.02
9650.72
9628.11
9604.43
9579.30
9552.97
9525.17
9495.97
9465.53
9433.11
9399.40
9364.27
9327.05
9288.26
9247.56
9205.09
9161.07
9115.04
9066.90
9016.81
8964.70
8910.56
8854.26
8795.91
8735.46
8672.68
8607.82
8540.79
8471.65
8400.00
8326.36
8250.52
8172.52
8092.69
8010.35
7925.74
7839.71
7751.29
7660.82
7568.68
7474.75
7378.77
7281.87
7182.31
7082.00
6979.77
6876.95
6772.11
6666.67
6560.03
6452.64
6343.69
6234.94
6125.53
6015.94
5905.00
5794.79
5684.07
5573.26
5462.80
5353.16
5242.63
5133.82
5024.89
4916.89
4809.78
4702.55
4596.64
4492.48
4389.27
4286.69
4185.03
4085.29
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
Ohms
DR 2253
DW 1202
DWS 1202 DD 1401
DW 1305 DD 1403
DO 2202 DW 1204 DD 1304
942.40
2366.30
1333.90
932.70
2340.60
1311.50
923.30
2314.60
1289.30
914.10
2288.50
1267.20
905.30
2262.30
1245.50
896.70
2235.90
1224.00
2209.50
1202.70
2182.90
1181.80
2156.30
1161.10
2129.70
1140.80
2103.00
1120.70
2076.30
1101.00
2049.70
1081.60
2023.10
1062.50
1996.50
1043.80
1970.00
1025.40
1943.60
1007.30
1917.40
989.60
1891.20
972.20
1865.20
955.20
1839.40
938.50
1813.70
922.20
1788.20
906.20
1762.90
890.60
1737.80
875.30
1713.00
860.40
1688.40
845.80
1664.10
831.60
1640.00
817.60
1616.20
804.00
1592.70
790.80
1569.50
777.80
1546.50
765.20
1523.90
752.90
1501.60
740.90
1479.60
729.20
1458.00
717.80
1436.90
706.70
1415.60
695,90
1394.90
685.30
1374.60
675.10
1354.60
665.10
1334.90
655.40
1315.60
645.90
1296.70
636.70
1278.00
627.70
1259.70
619.00
1241.80
610.50
1224.20
602.30
1206.90
594.30
1190.00
586.50
1173.40
578.90
1157.10
571.50
1141.20
564.30
1125.60
557.30
1110.30
550.60
1095.40
544.00
1080.70
537.50
1066.40
531.30
1052.40
525.20
1038.60
519.40
1025.20
513.60
1012.10
508.10
99.30
502.70
986.70
497.40
974.40
492.30
962.50
487.30
950.70
482.50
939.30
477.80
928.10
473.20
917.20
468.80
906.50
464.40
896.10
460.20
885.90
456.20
875.90
452.20
64
°C
DWT
DDT
DDU
DRT
DST
DOT
DOS
3986.77
3890.15
3795.37
3701.58
3609.00
3517.86
3428.40
3340.89
3255.55
3170.80
3089.15
3006.99
2927.86
2852.04
2776.13
2702.33
2629.17
2559.52
2490.80
2423.67
2358.25
2294.65
2232.41
2172.21
2112.94
2055.93
2000.00
1945.83
1892.99
1841.40
1791.84
1743.04
1695.73
1649.97
1605.81
1562.61
1520.39
1479.21
1439.82
1401.55
1363.68
1327.73
1292.23
1258.74
1225.76
1193.31
1162.17
1132.39
1103.20
1074.62
1047.45
1020.11
994.24
969.60
945.31
921.47
899.16
876.75
855.05
834.10
814.73
794.44
775.76
757.00
739.88
721.84
705.46
689.01
673.38
657.70
642.84
628.81
614.74
601.50
588.24
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
Ohms
DWT
DDT
DDU
DRT
DST
DOT
DOS
574.93
563.37
550.88
539.26
527.61
516.83
506.03
496.10
486.16
476.19
466.20
457.11
448.90
439.77
431.54
423.29
415.03
407.67
400.31
392.93
385.54
379.07
371.65
365.16
358.65
353.08
346.56
340.96
335.36
329.76
324.14
319.46
313.83
309.14
304.44
299.74
295.03
290.32
286.55
281.83
278.05
DR 2253
DW 1202
DWS 1202 DD 1401
DW 1305 DD 1403
DO 2202 DW 1204 DD 1304
866.20
448.30
856.70
444.60
847.50
440.90
838.40
437.40
829.60
433.90
821.00
430.60
812.60
427.30
804.40
424.20
796.40
421.10
788.50
418.10
780.90
415.10
773.40
412.30
766.20
409.50
759.10
406.80
752.10
404.20
745.40
401.70
738.80
399.20
732.30
396.80
726.00
394.40
719.90
392.10
713.90
389.90
708.10
387.80
702.40
385.60
696.80
383.60
691.40
381.60
686.00
379.60
680.90
377.70
675.80
375.90
670.90
374.10
666.10
372.30
661.40
370.60
656.80
369.00
652.30
367.40
647.90
365.80
643.70
364.20
639.50
362.70
635.40
361.30
631.40
359.80
627.60
358.50
623.80
357.10
620.10
355.80
DC Range Sensor Resistance Chart
°C
–20
–18
–16
–14
–12
–10
–8
–6
–4
–2
0
2
4
6
8
10
12
14
16
18
20
22
24
26
A701, A702, A703, A704, A705
°C
Ohms
°C
Ohms
331,020
293,370
260,370
231,410
205,960
183,560
163,820
146,400
131,000
117,380
105,310
94,596
85,080
76,614
69,078
62,355
56,352
50,985
46,185
41,883
38,022
34,557
31,440
28,634
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
64
66
68
70
72
74
26,107
23,827
21,768
19,907
18,223
16,697
15,314
14,059
12,919
11,882
10,937
10,077
9,292
8,577
7,922
7,324
6,777
6,275
5,815
5,394
5,006
4,650
4,323
4,021
76
78
80
82
84
86
88
90
92
94
96
98
100
102
104
106
108
110
112
114
116
118
120
Ohms
3,743
3,487
3,251
3,033
2,831
2,644
2,472
2,312
2,164
2,026
1,899
1,780
1,670
1,568
1,473
1,384
1,301
1,224
1,153
1,085
1,023
964
909
65
PRODUCT SELECTION
Valves
Valves
Valves
These valves are used for hot and/or chilled
water control fan-coil units, induction units,
solar energy on plants, small reheaters and
dehumidifiers (in electric/electronic
temperature control systems).
VST, VMT,
VTT
Fan-coil Unit and
Zone Valves
(2, 3 & 4-port)
INSTALLATION DETAILS
Stroke - 5.5mm
Pipe connections - male thread
Characteristic - equal percentage A-AB port
(VMT and VTT – B-AB
linear)
Rangeability - ≥ 50
Max fluid speed - 3m/sec
International pressure rating - PN 16
This range of valves are used to control hot
and cool water in zone systems, two/fourpipes terminal units and solar plants.
VSZ, VMZ,
VTZ
INSTALLATION DETAILS
Stroke - 3.5mm
Pipe connections - male thread
Characteristic - linear
Max fluid speed - 3m/sec
International pressure rating - PN 16
Fan-coil Unit and
Zone Valves
(2, 3 & 4-port)
Order code**
PN16 Valves
(2 & 3-port)
Size
Two-port
VST09
15mm
VST10
15mm
VST11
15mm
VST12
15mm
VST13
15mm
VST1
15mm
VST21
20mm
VST2
20mm
Three-port
VMT09
15mm
VMT10
15mm
VMT11
15mm
VMT12
15mm
VMT13
15mm
VMT1
15mm
VMT2
20mm
Three-port with built-in by-pass
VTT09
15mm
VTT10
15mm
VTT11
15mm
VTT12
15mm
VTT13
15mm
VTT1
15mm
VTT21
20mm
VTT2
20mm
Data Sheet - VST-VMT-VTT
Order code**
Size
Two-port
VSZ09B
15mm
VSZ10B
15mm
VSZ11B
15mm
VSZ12B
15mm
VSZ13B
15mm
VSZ1B
15mm
VSZ21B
20mm
VSZ2B
20mm
Three-port
VMZ09B
15mm
VMZ10B
15mm
VMZ11B
15mm
VMZ12B
15mm
VMZ13B
15mm
VMZ1B
15mm
VMZ2B
20mm
Three-port (4-port)
VTZ09B
15mm
VTZ10B
15mm
VTZ11B
15mm
VTZ12B
15mm
VTZ13B
15mm
VTZ1B
15mm
VTZ21B
20mm
VTZ2B
20mm
Data Sheet - VSZ-VMZ-VTZ
Both 2-port VSB and 3-port VMB valve bodies can be
used to control flow in air-conditioning, thermoventilation and heating systems, in environmental and
industrial plants for machines employed for thermic
treatment of products. 3-port valves must be used as
mixing valves only; the angle port should never be used
for control purposes. Valve stem down: straight-port open.
VSB, VMB
Valves
Flow rate
Kvs*, m3/h
Max pressure
rating (kPa)
Limits
0.25
0.4
0.6
1
1.6
2.5
2.5
4
350
350
350
350
350
350
250
250
Water - 95°C max, 2°C min
0.25 (0.25)
0.4 (0.25)
0.6 (0.4)
1
(0.6)
1.6 (1)
2.5 (1.6)
4
(2.5)
(4-port)
0.25 (0.25)
0.4 (0.25)
0.6 (0.4)
1
(0.6)
1.6 (1)
2.5 (1.6)
2.5 (1.6)
4
(2.5)
350
350
350
350
350
350
250
Flow rate
Kvs*, m3/h
0.25
0.4
0.6
1
1.6
2.5
2.5
4
(0.25)
(0.25)
(0.4)
(0.6)
(1)
(1.6)
(2.5)
150
150
150
150
150
150
150
0.25
0.4
0.6
1
1.6
2.5
2.5
4
(0.25)
(0.25)
(0.4)
(0.6)
(1)
(1.6)
(1.6)
(2.5)
150
150
150
150
150
150
150
150
Order codes
2-port
3-port
VSB11
VMB11
VSB1
VMB1
VSB15
VMB15
VSB2
VMB2
VSB3
VMB3
VSB4
VMB4
VSB5
VMB5
VSB6
VMB6
VSB8
VMB8
VSB8A
VMB8A
Data Sheet - VSB-VMB
INSTALLATION DETAILS
Stroke - 16.5mm (max 18.5mm)
Pipe connections - female thread
Characteristic - VSB - equal percentage
VMB - straight port - equal percentage,
angle port - linear
Rangeability - ≥ 50
International pressure rating - PN 16
Size
15mm
15mm
15mm
15mm
20mm
25mm
32mm
40mm
50mm
50mm
Notes:
100 KPa = 1 bar = 10 m H2O
∆Pmax = maximum
guaranteed differential
pressure with closed valve
and opened flow.
VT valves are motorised with
MVT actuators.
* The values in brackets
represent kvs on angle ways.
** Valves can be supplied
NPT threaded. To order, add
N to the ordering code, ie
VST2N.
Flow rate
Kvs, m3/h
1
1.6
2.5
4
6.3
8
16
22
30
40
66
PN16 Valves
(2 & 3-port)
VSBT (2-port) and VMBT (3-port) valves can be used for
fluid control in heating and air conditioning plants for
both residential and industrial use, as well as with
machines for thermic treatment. 3-port valves will only be
used for mixing. Angle port (B-AB) is never to be used
for control.
Order codes
2-port
3-port
VSBT3
VMBT3
VSBT4
VMBT4
VSBT5
VMBT5
VSBT6
VMBT6
INSTALLATION DETAILS
Stroke - 5.5mm
Pipe connections - female thread
Characteristic - linear
Rangeability - ≥ 50
Data Sheet - VSBT-VMBT
These 2-port single seat valves are used to
control fluids in air-conditioning, thermoventilation, heating plants and industrial
processes.
INSTALLATION DETAILS
Stroke - see data sheet
Characteristic - equal percentage
Limits
SS, VS
Water - 95°C max, 5°C min
Glycol added 50% max
Single Seat Globe
valves
(2-port)
ACCESSORY
245 – stem heater (24V) motorised with
MVL actuator
MAX DIFFERENTIAL PRESSURE (bar)
Size
Kvs
mm
VSG VSS
SS
SH
15R
–
–
1.6
–
15
–
–
4
–
25R
4
4
–
2 (10)
20
–
–
6.3
–
25I
6.3
6.3
–
2 (10)
25
10
10
10
2 (10)
32
–
16
16
–
40
25
25
22
2 (7.5)
50
32
40
32
2 (4.7)
65
63
63
63
2 (2.8)
80
100
–
110
1.7
100
130
–
140
0.8
125
200
–
–
0.5
150
300
–
–
0.3
15mm valve bodies can
be supplied with CONEX
connections (DN15). Add C
to the order code, ie VST2C.
Size
20mm
25mm
32mm
40mm
Flow rate
Kvs, m3/h
6.3
10
13
16
Max pressure
rating (kpa)
1600
(16 bar)
VSG
25...150mm
16
Cast iron
Brass
150°C
–10°C
NP16
Water - 95°C max,
5°C min
Glycol added
50% max
MAX DIFFERENTIAL PRESSURE (bar)
Order codes
Actuators – max ∆P (bar)
MVL
VSBT3
170
VSBT4
100
VSBT5
70
VSBT6
50
VMBT3
170
VMBT4
100
VMBT5
70
VMBT6
50
Construction
Limits
Notes:
100 KPa = 1 bar
∆Pmax = max differential
pressure value ensured by
actuator for regular working
conditions.
SS-GA
VSS
SS-AA
SS-AACP
15...100mm
25...65mm
15...100mm
15...100mm
16
25
40
40
Cast iron
Cast iron
Cast steel
Cast steel
Stainless steel Stainless steel Stainless steel Stainless steel
200°C
230°C
230°C
350°C**
–10°C
–10°C
–10°C
–30°C***
NP16
NP25
NP40
NP40
Body rating (bar)
Body
Plug
Max. fluid temp.
Min. fluid temp.*
Flanged
Data Sheet - SS-VS
Notes: * For applications free from icing on stem and packing, see accessory option 245.
** With finned bonnet, high temp and forced lubrication. Low temp Teflon packing.
*** For fluid temperature from –10 to –30°C add ‘B’ to the order code.
VSG
MVL
–
2 (10)
–
2 (10)
2 (10)
–
2 (9.5)
2 (6)
2 (3.6)
2 (2.3)
1.4
0.8
0.4
MVLA/C
–
–
2 (10)
–
2 (10)
2 (10)
–
2 (3.5)
2 (2.4)
1.4
0.8
0.4
–
–
SH
6 (16)
6 (16)
–
6 (16)
–
6 (16)
6 (16)
6 (10)
6 (7)
2.5
1.5
1
–
–
SS-GA
MVL MVLA/C
6 (16) 6 (16)
6 (16) 6 (16)
–
–
6 (16) 6 (14)
–
–
6 (16)
6 (9)
6 (16)
6 (9)
6 (13.5)
5.5
6 (9)
3.5
3.5
1.4
2.3
0.9
1.4
0.5
–
–
–
–
SH
–
–
8 (20)
–
8 (18)
8 (16)
7.5 (12)
6.5 (8)
5.2
2.7
–
–
–
–
VSS
MVL MVLA/C
–
–
–
–
8 (20) 7 (10)
–
–
8 (20) 7 (10)
8 (20) 7 (10)
8 (14)
6
8 (10)
4.5
6.5
2.7
3.7
1.4
–
–
–
–
–
–
–
–
SS-AA /
MVL
10 (30)
10 (30)
–
10 (30)
–
10 (20)
10 (20)
10 (13)
8
3.5
2.4
1.4
–
–
SS-AACP
MVLA/C
10 (30)
10 (20)
–
10 (12)
–
7.5
7.5
4.5
3
1
0.8
0.4
–
–
Notes: (100 KPa = 1 bar
∆Pmax = max differential pressure value ensured by the actuator for operation control.
Values in brackets are the maximum differential pressure values when valve is fully closed.
Max pressure
rating (kpa)
1600
(16 bar)
MAX DIFFERENTIAL PRESSURE (bar)
Order codes
Actuators – max ∆P (bar)
2-port
3-port
MVB
MVLA/C MVL
SH
+AG31 +AG31 +AG21
VSB1
VMB1
2 (10) 2 (10) 2 (10) 2 (10)
VSB11
VMB11
2 (10) 2 (10) 2 (10) 2 (10)
VSB15
VMB15
2 (10) 2 (10) 2 (10) 2 (10)
VSB2
VMB2
2 (10) 2 (10) 2 (10) 2 (10)
VSB3
VMB3
2 (10) 2 (10) 2 (10) 2 (10)
VSB4
VMB4
2 (6.5) 2 (10) 2 (10) 2 (10)
VSB5
VMB5
2 (4)
2 (6)
2 (10) 2 (10)
VSB6
VMB6
2 (2.5) 2 (4)
2 (8)
2 (8)
VSB8A
VMB8A
2 (2)
2 (3)
2 (6)
2 (6)
ACCESSORIES
AG21 – linkage kit for SH actuators
AG31 – linkage kit for MVL-MVLA/C actuators
VSBT, VMBT
15mm valve bodies can be
supplied with CONEX
connections (DN15). Add C
to the order code, ie VST2C.
Max pressure
rating (kPa)
0.25
0.4
0.6
1
1.6
2.5
4
(cont)
Glycol added 50% max
350
350
350
350
350
350
250
250
150
150
150
150
150
150
150
150
PRODUCT SELECTION
Water - 120°C max
–10°C min
Glycol added
50% max
Saturated steam
120°C max
1.5 bar absolute
max pressure
Construction
2-port double seat valves are used to control fluids in
air-conditioning, thermoventilation, heating plants and
industrial processes.
Limits
Double Seat
Globe Valves
(2-port)
DS-AACP
25...150mm
40
Cast steel
Stainless steel
350°C**
–30°C***
NP40
Body rating (bar)
Body
Plug
Max. fluid temp.
Min. fluid temp.*
Flanged
Data Sheet - DS
Notes: * For applications free from icing on stem and packing, see accessory 245.
** With finned bonnet, high temp and forced lubrication.
Low temp Teflon packing.
*** For fluid temperature from –10 to –30°C add ‘B’ to the order code.
INSTALLATION DETAILS
Stroke - see data sheet
Characteristic - equal percentage
DS
DS-AA
32...150mm
40
Cast steel
Stainless steel
230°C
–10°C
NP40
ACCESSORY
245 – stem heater (24V) motorised with MVL and
SH actuators
MAX DIFFERENTIAL PRESSURE (bar)
Size
Actuators – max ∆P (bar)
mm
Kvs
MVL
MVLA/C
32R (rid.)
10
12 (30)
12 (30)
32
16
12 (30)
12 (30)
40
22
12 (30)
12 (30)
50
32
12 (30)
12 (30)
65
63
12 (30)
12 (14)
80
85
12 (30)
11
100
160
12 (20)
8.5
125
200
12 (20)
8
150
300
12 (14)
7
200
500
–
–
Notes:
100 KPa = 1 bar
∆Pmax = max
differential pressure
value ensured by the
actuator for operation
control.
Values in brackets are
the maximum
differential pressure
values when valve is
fully closed.
67
Notes:
100 KPa = 1 bar
∆Pmax = max
differential pressure
value ensured by the
actuator for operation
control.
Values in brackets are
the maximum
differential pressure
values when valve is
fully closed.
PRODUCT SELECTION
Valves
Valves
Valves
(cont)
VBS, VBG
Balanced Valves
PN16, PN25
(2-port)
Valves
Order
codes
VBS25R
VBS25I
VBS25
VBS32
VBS40
VBS50
VBS65
VBG80
VBG100
VBG125
VBG150
VBS and VBG balanced valve bodies can be used to
control flow in air-conditioning, thermo-ventilation and
heating systems, in environmental plants for both
residential and industrial units. The special characteristic
of these valves is they can work under high close off
pressure and wherever low leakage is required. This
makes them particularly suitable for applications with
super-heated water (i.e. remote heating plants, boiler
feeding, etc) and steam.
INSTALLATION DETAILS
Characteristic - equal percentage
ACCESSORIES
244 – stem heater (24V) motorised with MVB actuator
246 – stem heater (24V) motorised with MVL and
SH actuators
Size
Flow rate
Kvs, m3/h
25mm
4
25mm
6.3
25mm
10
32mm
16
40mm
25
50mm
40
65mm
63
80mm
100
100mm
130
125mm
200
150mm
300
Stroke
(mm)
16.5
16.5
16.5
25
25
25
25
45
45
45
45
Pressure
rating
PN25
PRODUCT SELECTION
(cont)
Limits
Water - 230°C max, –10°C min
Glycol added – 50% max
Saturated steam 230°C max
7 bar absolute max pressure
VM, 3V
PN16
Water - 150°C max, –10°C min
Glycol added – 50% max
Saturated steam 150°C max
2 bar absolute max pressure
Globe Valves
(3-port)
3-port motorised valves are used to control
fluids in air-conditioning thermo-ventilation,
heating plants and industrial processes.
Construction
VMB16
25...150mm
INSTALLATION DETAILS
Stroke - see data sheet
Characteristic - all valves linear, except
VMB16 - straight port angle port = linear
ACCESSORY
245 – stem heater (24V) motorised with SH
and MVL actuators
Body rating (bar)
16
Body
Cast iron
Plug
Brass
Max. fluid temp.
150°C
Min. fluid temp.*
–10°C
Flanged
NP16
Data Sheet - VM-3V
3V-GA
100...125mm
VMS
3V-AA
3V-AACP
25...65mm
25...125mm
25...125mm
3VSA 80mm
16
25
40
40
Cast iron
Cast iron
Cast steel
Cast steel
Stainless steel Stainless steel Stainless steel Stainless steel
200°C
230°C
230°C
350°C**
–10°C
–10°C
–10°C
–30°C***
NP16
NP25
NP40
NP40
Notes: * For applications free from icing on stem and packing, see options 245.
** With finned bonnet, high temp and forced lubrication. Low temp Teflon packing.
*** For fluid temperature from –10 to –30°C add ‘B’ to the order code.
Data Sheet - VBS-VBG
MAX DIFFERENTIAL PRESSURE (bar)
Order codes
Actuators – max ∆P (bar)
MVL
MVLA/C
SH
VBS25
7 (25)
12 (30)
7 (25)
VBS32
7 (25)
12 (30)
7 (25)
VBS40
7 (25)
12 (30)
7 (25)
VBS50
7 (25)
12 (30)
7 (25)
VBS65
7 (25)
12 (14)
7 (25)
VBG80
2 (16)
2 (10)
2 (16)
VBG100
2 (16)
2 (8)
2 (16)
VBG125
2 (16)
2 (5.5)
2 (13.5)
VBG150
2 (14.5)
2 (4.5)
2 (10.5)
Notes:
100 KPa = 1 bar
∆Pmax = max
differential pressure
value ensured by the
actuator for operation
control.
Values in brackets are
the maximum
differential pressure
values when valve is
fully closed.
MAX DIFFERENTIAL PRESSURE (bar)
Size
Kvs
VMB 16
mm
VMB16 VMS
3V
SH
MVL MVLA/C
25R
4
4
4
2 (10) 2 (10) 2 (8)
25I
6.3
6.3
6.3
2 (10) 2 (10) 2 (8)
25
10
10
10
2 (10) 2 (10) 2 (8)
32
–
19
16
–
–
–
40R
19
–
–
2 (8) 2 (10) 2 (4)
40
25
25
22
2 (8) 2 (10) 2 (4)
50
32
40
32
2 (5) 2 (6.7) 2 (2.6)
65
63
63
70
2 (3) 2 (4)
1.5
80
100
–
110
1.8 2 (2.4)
0.9
100
130
–
140
1
1.5
0.5
125
200
–
250
0.6
0.9
0.25
150
300
–
–
0.4
0.5
0.15
VMS
3V-GA (DN 100 and 125) 3V-SATS (DN 80)
3V-SA (DN 80)
SH
MVL MVLA/C
SH
MVL MVLA/C
MVL MVLA/C
8 (16) 8 (20) 7 (10)
6 (16) 6 (16) 6 (9)
5
5
8 (16) 8 (18) 7 (9)
–
–
–
–
–
8 (16) 8 (18) 7 (9)
6 (16) 6 (16) 6 (9)
5
5
7.5 (10) 8 (13)
5.5
6 (10) 6 (14)
5.5
5
4
–
–
–
–
–
–
–
–
7
7.5 (9)
4
6 (7) 6 (9)
3.5
5
2.5
5
6.3
2.5
5
6
2.5
5
1.5
2.7
3.5
1.4
2.5
3.5
1.4
3
1
–
–
–
1.5
2
0.8
2
0.5
–
–
–
1
1.3
0.5
–
–
–
–
–
0.5
0.8
0.2
–
–
–
–
–
–
–
–
–
–
Notes: (100 KPa = 1 bar
∆Pmax = max differential pressure value ensured by the actuator for operation control.
Values in brackets are the maximum differential pressure values when valve is fully closed.
Butterfly motorised valves are used in heating,
refrigerating and hydraulic plants.
Order
codes
INSTALLATION DETAILS
Angular travel - 90°
Maximum fluid temperature - 120°C
VFG10-40
40mm
85
VFG10-50
50mm
130
VFG10-65
65mm
220
VFG10-80
80mm
340
VFG10-100
100mm
550
VFG10-125
125mm
900
VFG10-150
150mm
1400
VFG10-200
200mm
2500
Data Sheet - VF-ST400
Notes: Use ST or MDL actuators to drive valves.
2-port VSB.F and 3-port VMB.F valves can be used either
for flow control in air-conditioning, thermo-ventilation
and heating plants, both environmental and industrial, in
machines for product thermal process. 3-port valves
should be used only as mixing valves; angle port should
never be used for control purposes.
Order codes
Size
2-port
3-port
VSB11F
VMB11F 15mm
VSB1F
VMB1F
15mm
VSB15F
VMB15F 15mm
VSB2F
VMB2F
15mm
VSB3F
VMB3F
20mm
VSB4F
VMB4F
25mm
VSB5F
VMB5F
32mm
VSB6F
VMB6F
40mm
VSB8F
50mm
VSB8AF
VMB8F
50mm
VSB9F
VMB9F
65mm
Data Sheet - VSB.F-VMB.F
VFG10
PN10 Flanged
Valves
(2-port)
VSB.F, VMB.F
PN16 Flanged
Valves
(2 & 3-port)
INSTALLATION DETAILS
Stroke - 16.5mm (VSB9F & VMB9F 20mm)
Characteristic - VSB - equal percentage
VMB - straight port - equal percentage,
angle port - linear
Rangeability - ≥ 50
International pressure rating - PN 16
ACCESSORIES
AG21 – linkage kit for SH actuators
AG31 – linkage kit for MVL-MVLA/C actuators
Size
Flow rate
Kvs, m3/h
Max. differential
pressure rating (kPa)
with ST actuator
200
200
200
200
150
100
70
40
Flow rate
Kvs, m3/h
1
1.6
2.5
4
6.3
8
16
22
30
40
63
Max pressure
rating (kpa)
1600
(16 bar)
MAX DIFFERENTIAL PRESSURE (bar)
Order codes
Actuators – max ∆P (bar)
2-port
3-port
MVB
MVLA/C MVL
SH
+AG31 +AG31 +AG21
VSB1F
VMB1F
2 (10) 2 (10) 2 (10) 2 (10)
VSB11F
VMB11F 2 (10) 2 (10) 2 (10) 2 (10)
VSB15F
VMB15F 2 (10) 2 (10) 2 (10) 2 (10)
VSB2F
VMB2F
2 (10) 2 (10) 2 (10) 2 (10)
VSB3F
VMB3F
2 (10) 2 (10) 2 (10) 2 (10)
VSB4F
VMB4F
2 (6.5) 2 (10) 2 (10) 2 (10)
VSB5F
VMB5F
2 (4)
2 (6)
2 (10) 2 (10)
VSB6F
VMB6F
2 (2.5) 2 (4)
2 (8)
2 (8)
VSB8AF
VMB8F
2 (2)
2 (3)
2 (6)
2 (6)
VSB9F
VMB9F
1.5
1.5
2 (4)
–
68
Limits
Water - 120°C max
–10°C min
Glycol added
50% max
Saturated steam
120°C max
1.5 bar (absolute)
max pressure
Notes:
100 KPa = 1 bar
∆Pmax = max
differential pressure
value ensured by the
actuator for operation
control.
Values in brackets are
the maximum
differential pressure
values when valve is
fully closed.
69
3V-AA/3V-AACP
MVL MVLA/C
10 (20) 7.5
–
–
10 (20) 7.5
10 (12) 4.5
–
–
8.5
3
5.5
2
3.5
1
2
0.7
1.3
0.4
0.8
0.2
–
–
PRODUCT SELECTION
Actuators
Actuators
Actuators
Actuators
MVA actuators are used in V-ZB globe valve coupling for
cool/warm water control in two and four pipe terminal
units and zone systems.
Model
Control
Control signal
(power supply)
MVA21
MVA23
On/off (with cable)
On/off
110...230Vac
”
MVA41
MVA43
On/off PWM (with cable)
On/off PWM
24Vac
”
PRODUCT SELECTION
(cont)
MVL actuators have linear characteristic (linear ratio
between input signal and valve coupling joint movement).
They are used for fluid control in air-conditioning-heating
systems and in industrial processes.
Data Sheet - MVA2./4
MVA
INSTALLATION DETAILS
Action - direct
Stroke - 3.5mm (max)
Stroke time - 3 min (opening), 8 min (closing)
Thrust - 100 N (min)
Protection class - IP 31
Electro-thermal
Terminal Unit and
Zone Valve
Actuators
MVT4 actuator is designed to provide, with VST and VSBT
valve bodies, floating control of hot/cool water in
two/four-pipe fan-coil units, zone and solar plants, reheat
coils and dehumidification batteries.
Model
Control
Control signal
MVT44
3 position
24Vac
MVL
Pulsed and
Proportional Linear
Valve Actuators
(700N & 1500N)
Mod.
Two different control types are available:
- floating (3-point)
- proportional (dc voltage or current)
Raise Lower Actuators
MVL26
22
MVL46
22
MVL46A
22 (16)
MVL46C
22 (16)
They are designed for direct coupling on all Controlli
globe valves (add AG31 linkage for V.B valves) and they
may also be used easily on valves of other manufacturers
with 0...45 mm stroke for floating action models or
10...45 mm stroke for proportional action models.
Proportional Actuators
MVL56
22
MVL56A
22 (16)
MVL56C
22 (16)
Data Sheet - MVL
Remark:
INSTALLATION DETAILS
Stroke - MVL2/4 0...45 mm, MVL5 10...45 mm
Running speed - 1.33 s/mm
Thrust - MVL 1500 N, MVL.A/C 700 N
Protection class - IP 55
INSTALLATION DETAILS
Action - direct/reversing
Stroke - 6.5mm
Running speed - 30 s/mm at 50 Hz, 25 s/mm at 60 Hz
Thrust - 200 N
Protection class - IP 40
Fan-coli Pulsed
Valve Actuator
ST actuators are used to control VFG butterfly valves in
heating, refrigeration and hydraulic plants.
The MVT5 actuator is designed to provide proportional
control of both VST and VSBT valve bodies in fan-coil
units, solar plants, reheaters and recoolers using hot
and/or cold water.
Control signal
24Vac
Proportional – ranges 0...10, 6...10, 0...4,
2...10, 4...7, 6...9, 8...11Vac
ST
INSTALLATION DETAILS
Action - direct/reversing
Stroke - 6.5mm
Running speed - 30 s/mm at 50 Hz, 25 s/mm at 60 Hz
Thrust - 200 N
Protection class - IP 40
Fan-coil
Proportional Valve
Actuator
Pulsed and
Proportional Linear
Valve Actuators
(450N)
Supply
MVT56
Data Sheet - MVT5
MVT56
MVB
Model
Rotary Valve
Actuators
(100N)
These actuators are equipped with a reversing
synchronous motor and an electronic board available in
three different models respectively for:
- floating control
- proportional control (d.c. voltage or current)
Model
Timing (secs)
Supply
Control signal
MVB26
MVB46
MVB56
MVB52
65
65
65
30
230Vac
24Vac
24Vac
24Vac
Floating
”
Proportional (V– or mA)
”
Due to their versatility these actuators can be mounted
both on new ‘Controlli’ globe valves up to DN 2” as well
as on different manufacturers valves, with stroke from
10.8 to 20mm.
Data Sheet - MVB
Body valve
Nominal diameter
Model
PN16
PN16
DN 1/2”...2”
DN 1/2”...2”
VSB (2-port)
VMB (3-port)
INSTALLATION DETAILS
Angular travel - 90°
Timing - 360 secs
Torque - 10 Nm
Radial force - 100 N (max)
Protection class - IP 20
Shaft - Ø 20mm with 18x6 key
MDL
INSTALLATION DETAILS
Action - direct/reversing
Stroke - 21mm max (mechanical end stroke)
Thrust - 450 N
Protection class - IP 50
Output signal - for remote position indication 0...10V, 10...0V
Damper Actuators
SH
INSTALLATION DETAILS
Angular travel - 160°
Timing - 80 secs
Torque - 12 Nm
Radial force - 1200 N (max)
Protection class - IP 40
Shaft - Ø 16mm with pin hole Ø 4mm
Manual override
Model
Supply
Control signal
SH222
SH242
SH522
24Vac
230Vac
24Vac
2 positions, 3 points from controller
”
voltage or current variation from controller
60
60
60 (45)
60 (45)
230 V
24 V
24 V
24 V
floating
floating
floating
floating
33
33 (25)
33 (25)
60
60 (45)
60 (45)
24 V
24 V
24 V
prop. (V or mA)
prop. (V or mA)
prop. (V or mA)
MVL A/C models are fitted with spring return device.
Values in brackets indicate the spring return time.
A – spring return retracts (valve stem up)
C – spring return extends (valve stem down)
Supply
Control signal
ST404
ST405
24Vac
230Vac
2 positions, 3 points from controller
”
Stroke time (s)
90°C
160°C
Torque
(Nm)
Power
supply
Control
signal
MDL22
MDL24
MDL26
15
45
60
27
80
107
6
20
30
(8)
(27)
(40)
230Vac
”
”
3-point
”
”
MDL42
MDL44
MDL46
15
45
60
27
80
107
6
20
30
(8)
(27)
(40)
24Vac
”
”
3-point
”
”
MDL52
15
MDL54
45
MDL56
60
Data Sheet - MDL
27
80
107
6
20
30
(8)
(27)
(40)
24Vac
”
”
proportional
”
”
INSTALLATION DETAILS
Action - direct/reversing
Angular travel - 90° preset, 0...160° adjustable (55...160° adjustable - MDL5-)
Thrust - 500 N max
Protection class - IP 55
ACCESSORY
AF22 – coupling for VFG butterfly valves.
Data Sheet - SH--2
ACCESSORIES
AG21 – linkage kit for fitting actuator to VMB and VSB valves
D5 – one auxiliary microswitch (SPST) at end of stroke, rated 230V
P-140-1 – auxiliary potentiometer 140Ω
P-1000-1 – auxiliary potentiometer 1000Ω
245 – stem heater 24V (for valve applications with fluids below –10°C)
Pulsed and
Proportional Linear
Valve Actuators
(1200N)
70
33
33
33 (25)
33 (25)
Model
Model
ACCESSORIES
D36 – two auxiliary microswitches (SPDT) adjustable, rated 230V
MVBPA2 – potentiometer for MVB46 (pcb with 1KΩ auxiliary pot.)
244 – stem heater 24V (for valve applications with fluids below –10°C)
Series SH actuators are used in air conditioning,
thermoventilation, heating systems and in industrial
processes to drive dampers.
Input Control
Signal
Data Sheet - VF-ST400
The MDL actuators are used in civil and industrial systems
for driving dampers and other devices that require the
control of an angular position within a maximum angle of
160° (e.g. for adjusting the flame n liquid or gas burners).
Note: Timings refer to 16.5mm standard stroke. For different strokes see data sheet.
Supply
ACCESSORIES
DMVL – two auxiliary microswitches (SPDT) adjustable, rated 230V, 10 (3) amp.
MVLPA2 – potentiometer for MVL2 (pcb with 1KΩ auxiliary pot.)
MVLPA4 – potentiometer for MVL4
”
MVLPA4M – potentiometer for MVL46A and MVL46C
”
245 – stem heater 24V (for valve applications with fluids below –10°C)
AG31 – linkage kit for fitting actuator to VMB and VSG valves
Data Sheet - MVT
MVT44
Input Stroke/Time(s)
16.5
25
45
71
PRODUCT COMPATIBILITY
Compatibilty and Selection Chart
CONTROLLI
VALVE SIZING INFORMATION
Actuators
FLUID VALVE SIZING CHART
Flow liquid with
specific gravity 1
kg/d3
m3/h
Kvs =
Q - 10
∆pv
Q = flow m3/h
Flow liquid with specific gravity
∆pv = pressure drop (kPa)
Flow pressure drop kPa
(100 kPa = 1 bar = –10m H2O)
different than 1 kg/dm3 m3/h
Specific gravity
Example for fluids with specific gravity 1 kg/dm3 (water)
Example for fluids with specific gravity different than 1 kg/dm3
m3/h
Flow
: 30 m3/h fluid with specific gravity 0.9 kg/dm3
Pressure Drop : 20 kPa
– Locate the crossing point (right side of diagram) between the line with
starting point at specific gravity value 0.9 kg/dm3 and the sloping line at
flow value 30 m3/h.
– Locate the crossing point between the line with starting point at above
crossing point and the line at pressure drop value 20 kPa.
water
Flow
: 7.5
Pressure Drop : 55 kPa
– Locate the crossing point between the line with starting point at flow value
7.5 m3/h and the line at pressure drop value 55 kPa.
This point corresponds to flow coefficient Kvs 10, therefore control valve
must have Kvs = 10.
This point corresponds to flow coefficient Kvs 63, therefore control valve
must have size Kvs = 63 (DN65).
72
73
CONTROLLI
VALVE SIZING INFORMATION
STEAM VALVE SIZING CHART
CONDITIONS OF SALE
1.
2.
a)
b)
c)
3.
a)
b)
c)
4.
5.
6.
a)
b)
c)
d)
e)
f)
g)
7.
8.
a)
b)
c)
d)
e)
f)
g)
h)
i)
j)
k)
Pr
es
su
re
dr
op
l)
9.
a)
C
i
rit
ca
l
e
pr
ss
u
re
dr
op
b)
10.
11.
a)
b)
12.
a)
Example for superheated steam:
Flow
: 140 kg/h superheated steam
Absolute Inlet Pressure : 350 kPa
Temperature
: 209°C
Pressure Drop
: 100 kPa
Calculate the superheating degree as follows:
– Read the temperature value corresponding to 350 kPa (139°C)
Superheating degree – 209 –139 = 70°C
– Locate the crossing point (right side of diagram) between the line with
starting point at superheating 70°C and the sloping line of 140 kg/h flow.
– Locate the crossing point between the line with starting point at 350 kPa
inlet pressure and the sloping line at 100 kPa pressure drop.
– Locate the crossing point between lines with starting points.
Example for saturated steam:
Flow
: 4700 kg/h saturated steam
Absolute Inlet Pressure : 850 kPa
Pressure Drop
: 160 kPa
– Locate the crossing point between the line with starting point at absolute
inlet pressure 850 kPa and the sloping line of 160 kPa pressure drop.
– Locate the crossing point between the line with starting point at above
crossing point and the line of 4700 kg/h flow.
This point corresponds to flow coefficient Kvs 63, DN 65, therefore control
valve must have size 65mm.
This point corresponds to flow coefficient Kvs 4.
74
b)
c)
d)
13.
a)
Definitions
"Seller" means Satchwell Control Systems Limited. "Purchaser" means any party to whom Goods and/or Software are supplied
by the Seller. "Goods" means the products which are the subject of sale between the Purchaser and the Seller. "Software" means
the software or programs included in the Goods or ordered for use with the Goods. "Order" means any contract for the sale
of Goods and/or Software by the Seller to the Purchaser.
General
Orders are accepted by the Seller subject to these terms and conditions and any special conditions, which together form the
entire understanding between the parties, take precedence over any terms in the Purchaser's Order and supersede any previous
agreements statements or representations for which the Seller can accept no liability, save in the case of fraudulent
misrepresentation.
Unless otherwise stated quotations lapse 30 (thirty) days from the date they were made.
The Purchaser acknowledges that the Purchaser is not purchasing as a consumer.
Price
Unless otherwise specified, the price and relevant discount (if any) for the Goods and/or Software shall be that ruling at date
of despatch.
All prices are strictly nett and are exclusive of VAT and of all non-UK taxes, duties and levies.
The Seller reserves the right to review all prices quoted for the Goods and/or Software in the event of devaluation of the pound
sterling or fluctuation in rates of foreign exchange or the Euro.
Packing
Where special packing is ordered by the Purchaser, or is deemed necessary by the Seller, then the Seller will charge the
Purchaser with the full cost of such special packing. Otherwise packing in accordance with the Seller's standard procedure is
included in the product prices charged.
Limits of Contract
The Seller's acceptance of the Purchaser's Order includes only such Goods and/or Software as are specified in such acceptance.
Specifications
The descriptions and illustrations contained in the Seller's catalogues, brochures, price lists and other advertising media are
intended merely to present a general idea of the Goods and/or Software described therein and do not form part of any contract
for sale of the Goods and/or Software and no responsibility is accepted by the Seller for any errors or omissions therein or for
any loss and/or damage resulting from the Purchaser's reliance on such descriptions and illustrations.
Any performance figures given by the Seller are based upon the Seller's experience and are such as the Seller would expect to
obtain on test in the Seller's works. The Seller shall be under no liability for damages for failure to attain such figures unless
the Seller has guaranteed such performance figures in writing for the specific installation.
If the Goods and/or Software performance criteria obtained on any test is outside the guaranteed performance figures referred
to in 6.b) above, then the Seller will be given reasonable time and opportunity to rectify the said performance requirements.
Should the Seller fail to rectify the said performance requirements, then the Purchaser will be entitled to reject the Goods
and/or Software within twelve months of the date of delivery unless agreed otherwise in writing by the Seller.
The Purchaser assumes responsibility that the Goods and/or Software stipulated by the Purchaser are sufficient and suitable for
the Purchaser's intended purpose.
Unless expressly stated otherwise by the Seller, no responsibility is accepted by the Seller for any errors, omissions or other
defects in any drawings, designs or specifications not prepared by the Seller. The Purchaser will indemnify the Seller against
any and all liabilities and/or expenses so incurred by the Seller as a consequence of any such error, omission or other defect.
The Purchaser shall not copy, without the prior written consent of the Seller, any documentation supplied by the Seller.
All documentation supplied by the Seller shall remain at all times the property of the Seller.
Inspection and Tests
The Seller's products are carefully inspected and submitted to the Seller's standard tests at the Seller's works before despatch.
If tests in the presence of the Purchaser or the Purchaser's representative are required, these will be charged for. In the event
of any delay on the Purchaser's part in attending such tests or in carrying out any inspection required by the Purchaser after
seven days notice that the Seller is ready, the tests will proceed in the Purchaser's absence and shall be deemed to have been
made in the Purchaser's presence.
Despatch and Delivery
Any times quoted for despatch will date from the Seller's acceptance of the Purchaser's written Order and where necessary the
opening of an Irrevocable Letter of Credit.
Any dates given for despatch by the Seller are estimates only and will not involve the Seller in any liability for failure to despatch
on any particular date or dates. In the event that the Seller shall fail to despatch the Goods and/or Software within 30 days of
the estimated date, then the Purchaser shall be entitled to serve notice upon the Seller requiring the Seller to effect despatch
within 30 days of receipt of such notice, failing which, the Purchaser may terminate the Order without further charge on either
side.
If no delivery date is stated by the Purchaser then the Seller will deliver the Goods and/or Software within such reasonable
period as the Seller shall determine.
The Purchaser's Order may be dispatched in installments provided always that any such despatch will be deemed to be a
separate contract governed by these Conditions of Sale.
Unless expressly stated otherwise by the Seller, the Seller's price includes the cost of delivery of the Goods and/or Software to
an address or a carrier within the UK. The Purchaser shall state the point of delivery on the Order.
The Seller retains the right to select the method of carriage. Where the Purchaser orders any special carriage requirements, or
these are deemed necessary by the Seller, then the Seller will charge the Purchaser for the full cost of such special carriage
requirements.
Off-loading at the point of delivery shall in all circumstances be at the Purchaser's cost and risk unless otherwise agreed in
writing by the Seller.
Any dimensions, weight or quantities of packing stated by the Seller are estimates only.
In the event that the Purchaser or carrier fails to accept delivery of the Goods and/or Software, the Purchaser shall on demand
pay the Seller for and/or indemnify the Seller against any liabilities for all services provided or used by the Seller in
consequence, including, but not limited to, insurance, storage or handling and the Seller shall have a lien over any such Goods
and/or Software.
If the quantity of Goods and/or Software received by the Purchaser does not equate to the quantity of Goods and/or Software
ordered, (or in the case of part-shipments the quantities advised by the Seller) then the Purchaser is required to notify the
Seller in writing of the discrepancy within 7 calendar days of receipt of the Goods and/or Software. The Purchaser will not be
entitled to reject any Goods and/or Software by reason of short delivery.
Should the Purchaser return Goods and/or Software which the Seller has dispatched in accordance with the terms and
conditions of the Order without reason, then the Purchaser will pay a re-stocking charge to a maximum of 25% of the price of
the Goods and/or Software so returned.
Time for delivery shall not be of the essence.
Loss or Damage in Transit
The Seller will repair, or at the Seller's option replace, free of charge, Goods and/or Software lost or damaged up to the point
of delivery provided that the Seller and the carriers receive written notification of such damage within three days of delivery,
or if lost, within ten days from the date the Seller has acknowledged the Goods and/or Software will be dispatched. The Seller's
obligations hereunder are in lieu of all other liabilities that might otherwise arise in respect of such loss or damage and it's
consequences.
The Purchaser will afford the Seller reasonable opportunity to inspect the Goods and/or Software alleged to be damaged, as
and where delivered, should the Seller wish to do so.
Storage
If the Seller does not receive forwarding instructions sufficient to enable the Seller to despatch the Goods and/or Software
within 14 days of the acknowledged despatch date, the Seller shall be entitled to arrange alternative storage facilities or reallocate the Goods and/or Software at the Seller's sole discretion and any costs incurred by the Seller for storage, insurance or
demurrage shall be charged to the Purchaser.
Risk
Risk in the Goods and/or Software will pass to the Purchaser at the point of delivery.
It is a condition of the Order that both the Purchaser and the Seller shall individually effect and maintain adequate insurance
cover in respect of the risks each party has accepted under these Conditions of Sale.
Title
Title in the Goods (excluding Software) will not pass to the Purchaser until payment in full for the Goods has been received by
the Seller. Until such time, the Purchaser's possession of the Goods shall be as bailee for the Seller and the Purchaser will store
the Goods in a manner which enables the Goods to be clearly identified as the property of the Seller.
Notwithstanding 12(a) above:- (i) if the Goods and/or Software are purchased for re-sale by the Purchaser in the normal course
of the Purchaser's business, then the Purchaser may as agent for the Seller sell and deliver the Goods and/or Software to the
third party strictly on condition that all proceeds of such sales shall be held in trust and in a separate account for the Seller
until the time that full payment to the Seller has been effected. Until such time, the Seller reserves the option, on written
notice to the Purchaser, to have assigned to the Seller, all rights and claims which the Purchaser may have against third parties
arising from such sales. (ii) Should the Goods and/or Software be incorporated or combined with other items of equipment or
materials by the Purchaser or others acting on his behalf, then the Seller shall retain the legal and beneficial title to the Goods
and/or Software and the Purchaser agrees to store the Goods and/or Software so incorporated or combined in accordance with
the provisions of 12(a) above or the Purchaser may re-sell such Goods and/or Software to a third party subject to the terms of
12(b)i) above.
Should payment to the Seller for any Goods and/or Software become overdue, then the Seller reserves the right to repossess
any such Goods and/or Software and to re-sell the same. For this purpose the Purchaser will grant the Seller's representative
vehicular access, during normal business hours, to all or any of the premises used by the Purchaser for storing the Goods and/or
Software.
Title in the Software will remain at all times vested in the Seller.
Terms of Payment
Unless otherwise agreed in writing by the Seller payment in full for Goods and/or Software shall be received by the Seller at
Farnham Road, Slough, Berkshire SL1 4UH, England prior to date of despatch. Payment will be made in pounds sterling unless
REGISTERED IN ENGLAND: No. 00081433
agreed otherwise by the Seller and if made by cheque or other negotiable instrument, will not be effective until it is honoured
and the Seller's bank account is credited with the amount due.
b) Payment by the due date is the essence of every Order. Failure by the Purchaser to ensure payment is received by the Seller
on or before the due date shall entitle the Seller without prejudice to any other rights or remedies which the Seller may
possess:- (i) to withhold further despatches under this and any other contract existing between the Seller and the Purchaser
for the purchase of Goods and/or Software. (ii) to offset overdue monies against any sums which may be owed by the Seller
to the Purchaser under any other contract. (iii) to charge interest at 8 percent above the Bank of England's base rate in
accordance with The Late Payment of Commercial Debts (interest) Act 1998.
c) Any payment made by the Purchaser to the Seller which has not been apportioned by the Purchaser to specific debts will be
apportioned as the Seller believes to be correct.
d) Credit facilities extended by the Seller to the Purchaser are at the sole discretion of the Seller and may be revised or withdrawn
at any time without prior notification being provided to the Purchaser.
14. Defects after Delivery
a) Unless expressly stated otherwise by the Seller, the Seller will make good, by repair or at the Seller's option by the supply of a
replacement, defects which, under proper storage and use, appear in the Goods and/or Software within a period of twelve
calendar months after the Goods and/or Software have been dispatched and which arise solely from faulty design (other than
a design made, furnished or specified by the Purchaser for which the Seller has disclaimed responsibility in writing), materials
or workmanship: provided always that defective parts have been returned to the Seller if the Seller shall have so required. The
repaired or new parts will be delivered by the Seller free of charge as provided in condition 8 above.
b) In the case of Goods and/or Software not of the Seller's manufacture the Purchaser is entitled only to such benefits as the
Seller may receive under guarantees given to the Seller in respect thereof, but not so as to impose on the Seller in respect of
such parts or components a liability greater than that imposed upon the Seller by the preceding paragraph of this condition.
c) The Seller's liability under this condition 14. shall be in lieu of any warranty or condition implied by law as to the quality or
fitness for any particular purpose of the Goods and/or Software, and save as provided in this condition 14., the Seller shall not
be under any liability, whether in contract, tort or otherwise, in respect of defects in Goods and/or Software delivered or for
any injury (other than personal injury caused by the Seller's negligence as defined in Section 1 of the Unfair Contract Terms
Act, 1977), damage or loss resulting from such defects or from any work done in connection therewith.
15. Patents
The Seller will indemnify the Purchaser against any claim for infringement of Letters Patent, Registered Design, Trade Mark or
Copyright (published at the date of the Order) by the use or sale of any article or material supplied by the Seller to the
Purchaser and against all costs and damages which the Purchaser may incur in any action for such infringement or for which
the Purchaser may become liable in any such action. Provided always that this indemnity shall not apply to any infringement
which is due to the Seller having followed a design or instruction furnished or given by the Purchaser or to the use of such
article or material in a manner or for a purpose or in a country not specified by or disclosed to the Seller, or to any infringement
which is due to the use of such article or material in association or combination with any other article or material not supplied
by the Seller. Provided also that this indemnity is conditional on the Purchaser giving to the Seller the earliest possible notice
in writing of any claim being made or action threatened or brought against the Purchaser, the Purchaser not making any
admission of liability and on the Purchaser permitting the Seller at the Seller's own expense to conduct any litigation that may
ensue and all negotiations for a settlement of the claim. The Purchaser on his part warrants that any design or instruction
furnished or given by the Purchaser shall not be such as will cause the Seller to infringe any Letters Patent, Registered Design,
Trade Mark or Copyright in the execution of the Purchaser's order.
16. Liability
a) Notwithstanding the provisions of condition 14. above, the Seller will not, in any circumstances, be liable to the Purchaser or
a third party for any loss of use, loss of production, loss of reputation, loss of goodwill, loss of profit, loss of business, loss of
contracts, loss of revenues, loss of anticipated savings, increase in operating costs, financial or economic loss, indirect loss,
consequential loss or any other damage suffered.
b) Subject to condition 16 (c) below, the exclusions and limitations of liability set out in condition 16 (a) above will apply to all
claims of any kind whether as a result of breach of contract, statutory duty or warranty, negligence or otherwise on the part
of the Seller, its employees, agents, subcontractors or suppliers who will have no greater liability in relation to these Conditions
of Sale than the Seller.
c) The Seller will compensate the Purchaser for any legal liability for personal injury to or death of any person or damage to any
property to the extent that such personal injury or death or damage is caused by the negligence of the Seller or of its employees
or agents.
d) In the case of damage to property, other than the Goods and/or Software supplied under these Conditions of Sale, such
compensation will unless otherwise specified in these Conditions of Sale be limited to the value of Goods and/or Software
ordered in respect of any one occurrence or series of occurrences originating from one incident.
e) The total aggregate liability of the Seller for all other claims of any kind for any loss or damage resulting from its performances
or lack of performance under these Conditions of Sale in any twelve calendar month period will not in any event exceed an
amount equal to the value of Orders accepted by the Seller from the Purchaser in that twelve calendar month period.
f) The Purchaser will indemnify the Seller against any and all claims in respect of or consequent to pollution or to the release of
substances capable of causing harm to living organisms or interference with ecological systems arising from the Goods and/or
Software except in respect of personal injury or death, whether or not resulting from the negligence of any person.
g) If the Purchaser is not the sole end user and ultimate owner of the Goods and/or Software, then the Purchaser will ensure by
its contract with the end user or ultimate owner or its buyer that the Seller is given the benefit of the exclusions and limitations
of liability set out in these Conditions of Sale by all such users, owners and buyers and will indemnify the Seller against claims
of any kind by them to the extent that the Seller would not be liable to the Purchaser under these Conditions of Sale if the
claim had been made by the Purchaser.
17. Force Majeure
Should the Seller be delayed, hindered or otherwise prevented from complying with the terms of the Order by reason of events
or circumstances beyond the reasonable control of the Seller including but not limited to Acts of God, wars, riots, strikes,
lockouts, trade disputes, fuel shortages or labour disturbances, breakdown of plant or machinery, accident, storm, fire, flood,
difficulties in obtaining materials, transport or labour or any other circumstances affecting the supply of the Goods and/or
Software, then the Seller shall not be liable to the Purchaser for any loss or damage which may be suffered by the Purchaser
whether as a direct or indirect result of any such occurrences.
18. Software
All rights in the Software will remain at all times vested in the Seller. The Seller shall licence the Purchaser to use any Software
that is specified in an Order on the terms set out in the Seller's applicable Software/Computer Program Licence Agreement
provided with the Software. In the event that the Seller shall not have received payment in full for the Goods and/or Software
to which the licence relates within 30 days of the due payment date then the Purchaser's right to use the Software pursuant
to such Software/Computer Program Licence Agreement shall cease without further notice.
19. Cancellation
Should the Order be cancelled in whole or in part by the Purchaser prior to despatch of the Goods and/or Software then the
Purchaser agrees to reimburse the Seller for all costs arising from design, manufacture, packing and storage of the Goods
and/or Software and in addition shall pay compensation at a level of 20% of the Order value in respect of loss of profit,
restocking and administrative charges. The rights of the Purchaser to cancel the Order under this condition are without
prejudice to the rights of the Seller if such cancellation is executed vexatiously or otherwise amounts to a wrongful repudiation
of the Order.
20. Licences
Should any licence or consent of any government or other authority be required for procurement, carriage or use of the Goods
and/or Software by the Purchaser, then the Purchaser shall acquire the appropriate licence or consent at the Purchaser's own
expense and if requested by the Seller, shall produce evidence of the same on demand.
The failure of the Purchaser to obtain any necessary licence or consent will not entitle the Purchase to withhold or delay
payment of the purchase price beyond the due date. Should the Seller incur any additional direct or indirect expenses or
charges resulting from the Purchaser's failure to obtain any necessary licence or consent, then these will be for the Purchaser's
account.
21. Statutory and Other Regulations
If the cost to the Seller of performing the Seller's obligations under the Order shall be increased by reasons of the making or
amendment of any law or of any other regulation or bye-law having the force of law that shall affect the performance of the
Seller's obligation under the Order, the amount of such increase shall be added to the Order price.
22. Insolvency
The Seller shall, without prejudice to any of its other rights, be entitled at any time to stop any Goods and/or Software in transit
and/or suspend further deliveries or services and/or by notice in writing to the Purchaser determine the Order should the
Purchaser become bankrupt, make a composition or arrangement with its creditors, have a winding up order made or (except
for the purposes of amalgamation or reconstruction) a resolution for voluntary winding up passed or have a provisional
liquidator, receiver or manager of his business or undertaking duly appointed or having possession taken, by or on behalf of
the holders of any debentures secured by a floating charge.
23. Waiver
The failure by the Seller to exercise or enforce any rights under these Conditions of Sale shall not be deemed to be a waiver
of any such rights, neither will it operate so as to prevent the exercise or enforcement of the Seller's right at any time or times
thereafter.
24. Notices
Any notices given hereunder by the Seller or the Purchaser shall be deemed to have been duly given if sent to the last known
address of either party, by first class post three days after despatch or, on the date of despatch if given by telefax, telex,
telegraph or other electronic system of communication.
25. Contracts (Rights of Third Parties) Act 1999
The parties agree that no term or condition of these Conditions of Sale will be enforceable by virtue of the Contracts (Rights
of Third Parties) Act 1999 by any third party.
26. Legal Construction
Unless otherwise agreed in writing the Order shall in all respects be construed and operate as an English contract and in
conformity with English Law and is subject to the exclusive jurisdiction of the English Courts.
REGISTERED OFFICE: INVENSYS HOUSE, CARLISLE PLACE, LONDON SW1P 1BX, UNITED KINGDOM
75
SATCHWELL CONTROL SYSTEMS LIMITED (T/A CLIMATE CONTROLS EUROPE)
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement