No. SS2-MTG300-0100
MagneW Two-wire PLUS+
Smart Two-wire Electromagnetic Flowmeter
Model MTG18A (Integral type)
Model MTG14C/MTG18B (Remote type)
OVERVIEW
The MagneW Two-wire PLUS+ is a high
performance electromagnetic flowmeter based
on field proven Azbil Corporation's two-wire
loop powered technology. The MagneW Twowire PLUS offers the stable and accurate
measurement of a traditional magflow meter
with low power consumption. The result is a
lower overall cost of ownership.
FEATURES
Two-wire operation
MagneW Two-wire PLUS+ improves its noise
immunity performance by 700% maximum and
250% in average. For the spike noise, MagneW
Two-wire PLUS+ improves its noise immunity
performance in 250% in average.
High accuracy and stable output
MagneW Two-wire PLUS+ provides high
accuracy (± 0.5% of rate) and its output is as
stable as current four wired magnetic
flowmeters.
Minimum measurable fluid conductivity
The MagneW Two-wire PLUS+ offers a
minimum process fluid conductivity of 10μS/cm
which is the best among two-wire magflow
meters thereby maximizing applicability.
Wider range in size
MagneW Two-wire PLUS+ offers wider range in
detector size.
Detector size: 2.5 to 200 mm.
Wafer and flange style, integral and
remote style available
The MagneW Two-wire PLUS+ is available
integral or remote, flanged or wafer, making the
selection of the right meter for the application
simple.
Electrode status diagnostic function
The MagnoW Two-wire PLUS+ offers the
Integral type
Remote type
diagnostic function for the electrode condition.
It diagnoses the Empty pipe condition or scale
on electrode condition.
APPLICATIONS
• Corrosive liquid measurement
• Chemical solution measurement
• Drainage/waste disposal fluid measurement
• Drinking water and waste water service
• Industrial/agricultural water measurement
• Seawater measurement
-1-
2nd Edition
No. SS2-MTG300-0100
Azbil Corporation
FUNCTIONAL SPECIFICATIONS
EU Pressure Equipment Directive (97/23/
EC)
Model MTG18A and MTG18B are in accordance
with SEP category (Article 3, paragraph 3).
Enclosure rating
NEMA TYPE 4X, IEC IP67
Hazardous Areas certifications
for dangerous liquids
Integral type
FM approval
<for Division 1>
Class I, Division 1, Groups A, B, C & D, T4;
Class II, Division 1, Groups E, F & G, T4;
Class III, T4, -20°C < Tamb < +60°C
<for Division 2>
Nonincendive for
Class I, Division 2, Groups A, B, C & D, T4;
Class II, Division 2, Groups F & G, T4;
Class III, T4; Class I, Zone 2, Group IIC, T4,
-20°C < Tamb < +60°C
CSA certification
<for Division 1>
Class I, Division 1, Groups A, B, C & D, T4;
Class II, Division 1, Groups E, F & G, T4;
Class III, T4, -20°C < Tamb < +60°C
<for Division 2>
Class I, Division 2, Groups A, B, C, & D, T4;
Class II, Division 2, Groups E, F & G, T4;
Class III, T4, -20°C < Tamb < +60°C
ATEX(KEMA) Certification
<for Type n>
DN
Maximum Pressure
Less than 65mm
30bar
80mm
25bar
100mm
20bar
150mm
13bar
200mm
10bar
for non dangerous liquids
The maximum process pressure is 30bar for all
sizes.
Output signal
Analog output
4 to 20 mA DC
Digital output
DE
Analog or Digital output is selectable.
Pulse output
Open collector output (30V DC, 100 mA max.)
Pulse frequency: 0.0001 to 200 Hz
Pulse width: 1 ms to 1 s
LOW value: 2.7V (10mA) (Refer to the blow drawing.)
HIGH
II 3 GD
2.7V
LOW
Ex nA II T6 T135ºC at Tprocess: -40...+85ºC
Ex nA II T5 T135ºC at Tprocess: -40...+100ºC
Ex nA II T4 T135ºC at Tprocess: -40...+130ºC
-40ºC < Tamb < +60ºC
KEMA 07ATEX0066
IP66/67
0V
Contact output
Open collector output (30V DC, 100 mA max.)
Pulse or contact output is selectable
Communication protocol
SFC communication and HART communication
NEPSI Certification
<for Type n>
Ex nA II T6 DIP A21 TA 135ºC at Tprocess=85ºC
Ex nA II T5 DIP A21 TA 135ºC at Tprocess=100ºC
Ex nA II T4 DIP A21 TA 135ºC at Tprocess=130ºC
-40ºC < Tamb < +60ºC
Remote type
FM approval
<for Division 2>
Nonincendive for
Class I, Division 2, Groups A, B, C & D, T4;
Class II, Division 2, Groups F & G, T4;
Class III, T4; Class I, Zone 2, Group IIC, T4,
-20°C < Tamb < +60°C
CSA certification
<for Division 2>
Class I, Division 2, Groups A, B, C & D, T4;
Class II, Division 2, Groups E, F & G, T4;
Class III, T4, -20°C < Tamb < +60°C
HART® communication
• Multidrop mode: current fixed at 12mA
Optional Burst mode is not available.
Load resistance characteristic of
communication
External power supply 21.05 to 42V DC for
communication.
Load resistance (Ω)
2
1 21.05<V<30
R= V-15.6
0.0218
2 30<V<42
R= V-14.25
0.02383
1
Power supply (V DC )
Note) The load resistance of 250 Ω or more is
necessary for communications of SFC and
the HART communicator.
-2-
Azbil Corporation
No. SS2-MTG300-0100
Flow unit
The Electrode status diagnostic function makes the
analog output and pulse output to the values as
selected in the below "Electrode status output mode"
table.
The display alternately shows the output values
selected and "EMPTY OR SCALE ON
ELECTRODE".
There are five threshold levels to meet an
environment where the device is installed. Set an
appropriate threshold level from below.
SENSITIVITY HIGH
SENSITIVITY MID
SENSITIVITY LOW
SENSITIVITY LL
SENSITIVITY LLL
Default setting: OFF
Operating condition:
The following conditions must be met when using
the electrode status diagnostic function.
• Diameter: 10mm or larger
Volume flow:m³, L, cm³, G (gallon), mG, kG,
B (barrel), IG (imperial gallon), mIG,
kIG
Mass flow: t, kg, g, lb
Time:
d, h, min., s
Display
Display: LCD
Main display: 7-segment, 8 digits
Sub display: 16 digits, 2 lines
Display contents:
Simultaneously displays % flow rate, Actual flow
rate (eng. unit) and Totalized value.
Data setting
Operation by four key switches
Damping
Adjustable between 0.5 and 199.9 seconds.
Low flow cutoff
Adjustable between 0 and 10% of setting range.
Below selected value, output is driven to the zero
flow rate signal level.
• Electric conductivity of fluid: 30 μS/cm or greater
• Grounding: Grounding resistance must be less than
100Ω
Dropout
Adjustable between 0 and 10% of setting range.
Below selected value, pulse output is cut.
• The noise level must be over the set threshold when
the pipe is empty.
Electrode status diagnotic
• The noise level must be under the set threshold
when the process fluid flows in the detector.
Detect empty pipe condition or scale on electrode
condition by monitoring flow rate signal. Once the
flow rate signal fluctuates over a certain threshold,
the device judges that the detector is empty or scale
appears on the electrode.
“Electrode status output mode” table”
Output/Display
Analog 4 – 20mA
output
Pulse output
Display
Parameter selection in the “Electrode status output mode”
OFF
Output values as the
meter measures.
Output values as the
meter measures.
Display the value as
it measures.
ZERO
HOLD
Analog output is fixed to 0% (4mA). Analog output is held at
its last good value.
Pulse output is fixed to 0 (does not
Pulse output is held at
generate pulses).
its present state.
Flashes the message 0% and “Empty Flashes the values at its
last good values and a
or scale on electrode” alternately
message of “Empty or
(when % flow rate is specified for
scale on electrode”
the main display).
alternately.
Flashes the message 0.000 RATE
and “Empty or scale on electrode”
alternately (when actual flow rate is
specified for the main display).
Flashes the message XXXXXXXX
(totalized value at setup) and “Empty
or scale on electrode” alternately
(when totalized value is specified for
the main display).
-3-
No. SS2-MTG300-0100
Azbil Corporation
Lightning protection
10, 15, 25, 40, 50, 65, 80, 100, 150, 200 mm (3/8,
1/2, 1, 1½, 2, 2½, 3, 4, 6, 8 inches)
12 kV, 1000A
Equipped with the lightning arrester in the power
source and external output terminals.
Flange rating
ANSI150, ANSI300, DIN PN10, DIN PN16, DIN
PN25, JIS10K, JIS20K, JIS30K
Power failure
An EEPROM retains data record of totalized value
when pulse output is used (retention period
approximately 10 years).
Reference flange standard
JIS; JIS B2210 (1984)
ANSI; ANSI B16.5 (1988)
Power supply
Ambient temperature limits
15.6 to 42V DC (without communication)
21.05 to 42V DC (with communication)
Current capacity: 24mA min.
In case of current capacity is 22mA, the voltage must
be 15.6V minimum.
-20 to 60°C (-4 to 140°F)
Ambient humidity limits
10 to 90% RH
Vibration effect
Size
Integral style: 4.9m/s2(0.5G) max.
Remote style converter: 19.6m/s2(2G) max.
Remote style detector: 19.6m/s2(2G) max.
Wafer style
25, 40, 50, 65, 80, 100 mm (1, 1½, 2, 2½, 3, 4 inches)
Flange style
2.5, 5 mm (0.1, 0.2 inch) (Model MTG18A only)
Temperature range and pressure range of process fluid
Refer to the following.
Size: 2.5 to 10 mm (0.1 to 3/8 inch)
Size: 15 to 200 mm (1/2 to 8 inch)
2.94 MPa
(426 psi)
2.94 MPa
(426 psi)
1.96 MPa
(284 psi)
0.98 MPa
(142 psi)
-0.098 MPa
(-14.2 psi)
-20 C
(-4 F)
-0.098 MPa
(-14.2 psi)
-20 C
(-4 F)
80 C 100 C
(176 F)(212 F)
80 C 120 C 130 C
(176 F) (248 F) (266 F)
Measurable electrical conductivity
10 μS/cm or greater
50 μS/cm or greater (10 mm (3/8 inch), 15 mm (1/2 inch) for remote type)
Measurement flow range
Size
Maximum flow velocity range is
0 to 0.3 m/s (0 to 0.98 ft/s)
Maximum flow velocity range is
0 to 10 m/s (0 to 32.8 ft/s)
Minimum range
Maximum range
Conversion
factor K
mm
inches
m3/h
GPM
m3/h
GPM
2.5
0.1
0 to 0.00531
0 to 0.02335
0 to 0.1767
0 to 0.778
56.59
5
0.2
0 to 0.02121
0 to 0.09337
0 to 0.7068
0 to 3.112
14.15
10
3/8
0 to 0.08483
0 to 0.3735
0 to 2.827
0 to 12.44
3.537
15
1/2
0 to 0.1909
0 to 0.8404
0 to 6.361
0 to 28.00
1.572
25
1
0 to 0.5302
0 to 2.335
0 to 17.67
0 to 77.80
0.5659
40
1½
0 to 1.358
0 to 5.976
0 to 45.23
0 to 199.1
0.2210
50
2
0 to 2.121
0 to 9.337
0 to 70.68
0 to 311.2
0.1415
65
2½
0 to 3.584
0 to 15.78
0 to 119.4
0 to 525.9
0.08371
80
3
0 to 5.429
0 to 23.91
0 to 180.9
0 to 796.7
0.05526
100
4
0 to 8.483
0 to 37.35
0 to 282.7
0 to 1244
0.03537
150
6
0 to 19.09
0 to 84.04
0 to 636.1
0 to 2800
0.01572
200
8
0 to 33.93
0 to 149.4
0 to 1130
0 to 4979
0.008842
Velocity V (m/s) = K × Q
K = Conversion factor = 1/3600 × 4/(πD²) × 1000², D = Size (mm), Q = Flow rate (m³/h)
-4-
Azbil Corporation
No. SS2-MTG300-0100
PERFORMANCE SPECIFICATIONS
Size 25 to 200 mm (1 to 8 inches):
SUS304 stainless steel
Measuring pipe material
SUS304 stainless steel
Analog output accuracy
Size: 2.5, 5 mm (0.1, 0.2 inch)
Vs = velocity of setting range (m/s)
Vs (m/s)
Velocity during
measurement >
Vs×50%
Velocity during
measurement <
Vs×50%
1.0 ≤ Vs ≤ 10
±0.5% of rate
±0.5% of Vs
0.3 ≤ Vs ≤ 1.0
± ------- % of rate
0.5
Vs
Flange
SUS304 stainless steel
(size 2.5 to 65 mm (0.1 to 2½ inches))
Carbon steel + corrosion-preventive painting
(size 80 to 200 mm (3 to 8 inches))
0.5
± 0.5 + ⎛ -------⎞ % of Vs
⎝ Vs ⎠
Process wetted materials
Lining: PFA
Electrodes
SUS316L, ASTM B574 (Hastelloy C-276 equivalent),
Titanium, Tantalum, Nickel, Zirconium, PlatinumIridium
Grounding rings
SUS316, ASTM B575 (Hastelloy C-276 equivalent),
Titanium, Tantalum, Zirconium, Platinum
Size: 10, 15 mm (3/8, 1/2 inch)
Vs = velocity of setting range (m/s)
Vs (m/s)
Velocity during
measurement >
Vs×40%
Velocity during
measurement <
Vs×40%
1.0 ≤ Vs ≤ 10
±0.5% of rate
±0.5% of Vs
0.3 ≤ Vs ≤ 1.0
± ------- % of rate
0.5
Vs
0.5
-⎞ % of Vs
± 0.4 + ⎛⎝ -----Vs ⎠
Size: 25 to 200 mm (1 to 8 inches)
INSTALLATION
Vs = velocity of setting range (m/s)
Vs (m/s)
Velocity during
measurement >
Vs×30%
Velocity during
measurement <
Vs×30%
1.0 ≤ Vs ≤ 10
±0.5% of rate
±0.5% of Vs
0.3 ≤ Vs ≤ 1.0
± ------- % of rate
0.5
Vs
Electrical connection
1/2NPT internal thread (must be selected for FM approval)
CM20 internal thread
G1/2 internal thread
Remote converter mounting
0.5
± 0.3 + ⎛⎝ -------⎞⎠ % of Vs
Vs
Wall mounting, 2-inch pipe mounting
Grounding
Accuracy is guaranteed by the totalized flow volume
under the condition of continuous flow measurement
for 30 seconds or longer.
The grounding is essential for flow measurement.
The most effective grounding method is direct
connection to earth ground with minimal impedance.
For approval selection code “1”, to maintain Intrinsic
safety of system connect conductor to earth ground
so that it has less than 1 Ohm to earth ground. See
ANSI/ISA RP12.06.01 Installation of Intrinsically
Safe Systems for Hazardous (Classified) Locations
for guidance on installation of intrinsically safe
apparatus and systems.
PHYSICAL SPECIFICATIONS
Converter case finishing
Standard
Baked acrylic paint
Corrosion-proof
Baked epoxy paint
Pipe connection
Converter case material
Aluminum alloy
Wafer style (Size: 25 to 100 mm (1 to 4 inches))
Flange style (Size: 2.5 to 200 mm (0.1 to 8 inches))
Display cover material
Length of straight pipe
Tempered glass
Required straight pipe length clearance on the
upstream side and the downstream side, while
installing the detector.
Upstream side
A minimum 5D straight pipe length is required.
A minimum 10D straight pipe length is required if a
diffuser/valve/pump is installed upstream side.
Downstream side
2D straight pipe length is recommended.
(Where D is the nominal bore diameter of the
detector)
Terminal box finishing (Model MTG18B only)
Standard: Baked acrylic paint
Corrosion-proof: Baked epoxy paint
Terminal box material (Model MTG18B only)
Aluminum alloy
Detector main body materials
Case material
Size 2.5 to 15 mm (0.1 to 1/2 inch):
SCS13 stainless steel
-5-
No. SS2-MTG300-0100
Azbil Corporation
Cable between converter and detector
Upstream side
Right-angle joint
Diffuser with cone angle
greater than 15
detector
(If cone angle is 15 or less,
considered as straight pipe)
(Remote type)
Length
70 m (233 ft) or shorter
(25 mm (1 inch) to 200 mm (8 inches))
30 m (98 ft) or shorter
(10 mm (3/8 inch), 15 mm (1/2 inch))
Outside diameter
11.4 mm (0.45 inch)
detector
Greater than 5 dia.
Greater than 10 dia.
Greater than 5 dia.
Gate Value
(completely open)
detector
Greater than 5 dia.
Maximum cable length of SMC11 cable
detector
Process fluid conductivity [ S/cm]
detector
T joint
Concentrator
(considered as
straight-pipe section)
Greater than 5 dia.
Any Control Value
detector
Greater than 10 dia.
Any pump
P
Size 10mm, 15mm
Size 25mm or larger
50
10
2m
30m
70m
Cable length [m]
Greater than 10 dia.
Figure 2 Maximum cable length of SMC11 cable
Figure 1
-6-
Azbil Corporation
No. SS2-MTG300-0100
Notice for installation
Example: Sodium hypochlorite with 200V and
30kA
Four wire magnetic flowmeter is recommended.
• Application which pipe frequently becomes
empty
Both two wire magnetic flowmeter and four
wire magnetic flowmeter have empty pipe
detection function. The two wire magnetic
flowmeter detects empty by monitoring signal
fluctuation caused by empty pipe condition.
Therefore the empty pipe detection function of
the two wire magnetic flowmeter sometimes
does not work properly if noise level is too low
or too high. The four wire magnetic flowmeter
detects empty by monitoring impedance
between electrodes and grounding. So the four
wire magnetic flowmeter directly monitors the
empty pipe condition. If the application
requires empty detection quickly and perfectly, the four wire magnetic flowmeter is recommended.
• Plastic piping or piping with liner
If the customer piping is plastic or lined with
insulation material, process fluid may not be
properly grounded. In such case, it is recommended to connect earth wire between
upstream side grounding ring and downstream
side grounding ring for better grounding.
• Slurry application
Process fluid with slurry exceeds 3% is not
suitable for the two wire magnetic flowmeter.
The four wire magnetic flowmeter is recommended for the fluid with slurry concentration
more than 3%.
If hard particles hit the electrode, output of the
two wire magnetic flowmeter may fluctuate
even though the slurry concentration is less
than 3%. In this case, the four wire magnetic
flowmeter is recommended.
• Electrochemically homogeneous fluid Install
the device where the process fluid is electrochemically homogeneous. If two kind of process fluids are mixed at the upstream side, the
process fluid must be uniformly mixed.
• The application which the electric conductivity
changes or non-homogeneous fluid Do not use
the device for the following fluid conditions
even if the electric conductivity, temperature,
and pressure are within the device specifica-
To fully enjoy the performance of the device, please
choose an appropriate location according to the following.
Notice after installation
WARNING
When removing the device from the piping, make
sure that there is no line pressure or process fluid
inside of the device. Removing the device before
depressurizing may result in serious injury.
CAUTION
Do not use the device as a foothold. It may cause
injury or damage of the device.
Notice for environment
• Install the flowmeter in a location with an
ambient temperature of -25°C to 60°C (-13°F to
140°F) and an ambient humidity of 5 to
100%RH to prevent equipment malfunction or
output errors.
• Do not install the flowmeter in a location subject to severe vibration or in a highly corrosive
atmosphere. The converter and detector can be
damaged. * When install some electromagnetic
flowmeters in closer location, keep minimum
500mm (20 inch) space from each flowmeter.
Closer electromagnetic flowmeter installation
may cause magnetic interference each other
and results in output errors.
• Do not install the flowmeter in a location subject to severe vibration or in a highly corrosive
atmosphere. The converter and detector can be
damaged.
• When install some electromagnetic flowmeters
in closer location, keep minimum 500mm (20
inch) space from each flowmeter. Closer electromagnetic flowmeter installation may cause
magnetic interference each other and results in
output errors.
Notice for application
• Electrolytic bath application, process fluid with
higher voltage/current
Process fluid of the electrolytic bath application is mostly with high voltage/current.
It is not a suitable application for the two wire
loop powered magnetic flowmeter.
-7-
No. SS2-MTG300-0100
Azbil Corporation
tions. Those fluid may cause of inaccurate flow
measurement.
• Fluids that have sufficient conductivity at high temperature but do not meet the conductivity requirement at room temperature (about 20ºC (68ºF)).
(e.g. fatty acids and soap)
• Some fluids contain surfactant
(e.g. rinse, shampoo and CWM (coal water mixture))
• Insulating adhesive materials
(e.g. kaolinite, kaolin, calcium stearate)
• The analog output may fluctuate due to flow
noise, which is generated by the process fluid
flow. In such a case, connect the upstream
grounding ring to the downstream grounding
ring by a wire. The output fluctuation may be
reduced.
• The following fluids will permeate the PFA
liner. The vent hole option is recommended for
the following fluids.
• Nitric acid
• Aqueous ammonia
• High temperature sodium hydrate
Caution On PLC Connection
A circuit in some PLC may affect the flow measurement and the analog output may fluctuate.
In this case, make sure that the both PLC and the
MagneW Two-wire PLUS+ flowmeter are properly grounded. Proper grounding solves the
fluctuation problem.
CAUTION
In accordance with the safety standards of flameproof
regulation, please comply with the following instructions.:
(1) The voltage of general equipment such as the
power supply and the receiver should not
exceed 250VAC, 50/60Hz, 250VDC at any
time at normal or abnormal operation.
(2) The ambient temperature around the device
is 50ºC (122ºF) maximum.
(3) The process fluid temperature is 125ºC
(257ºF) max. for the size of 15mm (1/2 inch)
or larger.
(4) The process fluid temperature is 100ºC
(212ºF) max. for the size of 10mm (3/8 inch)
or smaller.
(5) Use the specified flameproof cable glands.
(6) Wait for seven minutes after switching OFF
the power supply, before opening the front
cover or the terminal cover.
A specified explosion-proof performance is available only when this device is used under the conditions described above.
Notice for power supply
• Use the following power supply. If the power
supply does not meet the following specifications, this device may not work.
• Current capacity: 24mA min.
-8-
Azbil Corporation
No. SS2-MTG300-0100
MODEL SELECTION
MagneW Two-wire PLUS+
Model MTG18A - I II III IV V VI VII VIII IX X XI - XII XIII - Options (some options can be selected per each model)
Selections
Optional selections Options
MTG18A
I
Line size
II Lining
III Pipe
connection
2.5 mm (0.1 inch) (flange type only)
5 mm
(0.2 inch) (flange type only)
10 mm (3/8 inch) (flange type only)
15 mm (0.5 inch) (flange type only)
25 mm (1 inch)
40 mm (1½ inches)
50 mm (2 inches)
65 mm (2½ inches)
80 mm (3 inches)
100 mm (4 inches)
150 mm (6 inches) (flange type only)
200 mm (8 inches) (flange type only)
PFA
Wafer JIS10K
Wafer JIS16/20K
002
005
010
015
025
040
050
065
080
100
150
200
*1
*1
*1
*1
X None
B Traccability certificale
C Material certificate (electrode/
grounding ring)
G Gasket for plastic piping
J Tropical treatment
K with tagging on the converter
housing
*3
L with tag number plate wired to
the flowmeter
*6
P
X Finish /
2 paint
11
12
Wafer JIS30K
13
Wafer ANSI 150
21
Wafer ANSI 300
22
Wafer DIN PN10
41
Wafer DIN PN16
42
Wafer DIN PN25
43
Flange JIS10K
J1
Flange JIS20K
J2
Flange JIS30K
Standard paint
Corrosion-proof paint
XII
X Bolt and None
2 nut
SUS304 (only for wafer type)
XIII
J3
Flange JIS10K for 10 mm size flange
*2
Flange JIS20K for 10 mm size flange
*2
Flange ANSI 150
Options
Basic model no.
J4
J5
A1
Flange ANSI 300
A2
Flange DIN PN10
D1
Flange DIN PN16
D2
Flange DIN PN25
D3
IV Electrode
V
VI
VII
VIII
IX
X
XI
SUS316L
L
ASTM B574 (Hastelloy C-276 equivalent)
C
Titanium
K
Zirconium
H
Tantalum
T
Nickel
N
Platinum-iridium
P
Grounding
SUS316
S
ring
ASTM B575 (Hastelloy C-276 equivalent)
C
Titanium
K
Zirconium
H
Tantalum
T
Platinum
P
Nickel
N
Wiring
G1/2 internal thread
A
connection
G1/2 internal thread with plastic water tight gland
B
G1/2 internal thread with brass Ni-plated watertight gland
C
1/2NPT internal thread (must be selected for FM approval)*4
D
CM20 internal thread
E
G1/2 internal thread with two plastic watertight glands
J
G1/2 internal thread with two brass Ni-plated watertight gland
K
Face-to-face Standard
A
dimension
Replacement for SMT3000 (for wafer type 40 to 100 mm)
S
Installation / Horizontal piping / Right side viewed from upstream
Display
Horizontal piping / Left side viewed from upstream
direction
Horizontal piping / Downstream side
Horizontal piping / Upstream side
Vertical piping / Right side of piping / Flow direction: Upward
Vertical piping mounting / Left side of piping / Flow direction: Upward
Calibration
Standard
Output / com- Volume flow 4-20mA DC output/with SFC communication
munication
Volume flow DE output/with communication
Volume flow 4-20mA DC output with HART communication
Approval/
None
Certification FM approval, Class I, II, III, Division 1, Groups A, B, C, D, E, F & G, T4
CSA certification, Class I, II, III, Division 1, Groups A, B, C, D, E, F & G, T4
FM approval, NI for Class I, II, III, Division 2, Groups A, B, C, D, F & G, T4
CSA certification, Class I, II, III, Division2, Groups A, B, C, D, E, F & G, T4
ATEX Type nA certification
NPSI Type nA certification Ex nAII T4 to T6
-9-
Display direction code "A"
Display direction code "B"
Display
Direction
of flow
Direction
of flow
Display
Display direction code "C"
Display direction code "D"
Display
A
B
C
D
E
F
Display
Direction
of flow
Direction
of flow
Display direction code "E"
Display direction code "F"
J
E
D
T
Direction
of flow
X
*5
1
*5
2
4
6
Note)
Direction
of flow
*1: Flange of size 2.5 to 15 mm detector is 15 mm
flange.
*2: Available for size 2.5 to 10 mm detector.
*3: Must be selected if tagging is required.
*4: Must select “Approval 1 or 2”.
*5: Must select “Wiring connection D”.
*6: This option is not applicable except if the
approval/certification code is "X."
No. SS2-MTG300-0100
Azbil Corporation
MagneW Two-wire PLUS+ Wafer/Flange remote type converter
Model MTG14C - I II III IV - Options (some options can be selected per each model)
Basic model no.
Selections
Options
MTG14C
I
Analog output /
communication
-
Volume flow 4-20 mA DC output / with SFC communication
E
Volume flow DE output / with communication
D
Volume flow 4-20 mA DC output / with HART communication T
II
Wiring connection
III Converter mounting
IV Approval
G1/2 internal thread
A
G1/2 internal thread with a plastic water-tight gland
B
G1/2 internal thread with a brass Ni-plated water-tight gland
C
1/2NPT internal thread
D
CM20 internal thread
E
Wall mounting with standard bracket
G
2-inch pipe mounting with standard bracket
H
None
X
FM approval, Class I, II, III, Division 2, Groups A, B, C, D, F & G, T4
CSA certification, Class I, II, III, Division 2, Groups A, B, C, D, E, F & G, T4
*2 2
-
V
Option
None
X
Traceability certificate
B
With the Tag number plate on the converter housing
*1 K
Corrosion-proof paint
2
Note) *1: Must be selected if tagging is required.
*2: Must select “Wiring connection D”.
MagneW Two-wire PLUS+ Wafer/Flange remote type cable
Model SMC11 - I II III
Basic model no.
Selections
SMC11
I
II
Cable
Terminals for detector
III Terminals for converter
2m
(6 feet 8 inches)
02
3m
(10 feet)
03
4m
(13 feet 4 inches)
04
5m
(16 feet 8 inches)
05
10 m (33 feet 4 inches)
10
15 m (50 feet)
15
20 m (66 feet 8 inches)
20
30 m (100 feet)
30
40 m (133 feet 4 inches)
40
50 m (166 feet 8 inches)
50
60 m (200 feet)
60
70 m (233 feet 4 inches)
70
With terminals
A
With terminals
A
- 10 -
Azbil Corporation
No. SS2-MTG300-0100
MagneW Two-wire PLUS+ Wafer/Flange remote type detector
Model MTG18B - I II III IV V VI VII VIII IX - Options (some options can be selected per each model)
Basic model no.
Selections
Options
MTG18B
II Lining
10 mm
(3/8 inch)
010
X None
15 mm
(1/2 inch)
015
B Traceability certificate
25 mm
(1 inch)
025
40 mm
(1½ inches)
040
C Material certificate (electrode/ grounding
ring)
50 mm
(2 inches)
050
G Gasket for plastic piping
65 mm
(2½ inches)
065
80 mm
(3 inches)
080
K With the Tag number plate on the
terminal box *1
100 mm (4 inches)
100
2 Corrosion-proof paint
150 mm (6 inches)
150
200 mm (8 inches)
200
4 Attached stainless steel 304 bolts and nuts
for installation *2
PFA
III Pipe
Wafer JIS10K
connection Wafer JIS16/20K
IV Electrode
P
11
12
Wafer JIS30K
13
Wafer ANSI 150
21
Wafer ANSI 300
22
Wafer DIN PN10
41
Wafer DIN PN16
42
Wafer DIN PN25
43
Flange JIS10K
J1
Flange JIS20K
J2
Flange JIS30K
J3
Flange JIS10K for 10 mm size flange
J4
Flange JIS20K for 10 mm size flange
J5
Flange ANSI 150
A1
Flange ANSI 300
A2
Flange DIN PN10
D1
Flange DIN PN16
D2
Flange DIN PN25
D3
Note)
*1: Must be selected if tagging is required.
*2: Available for wafer type.
*3: Must select “Wiring connection D”.
SUS316L
L
ASTM B574 (Hastelloy C-276 equivalent)
C
Titanium
K
Zirconium
H
Tantalum
T
Nickel
N
Platinum-iridium
P
V Grounding SUS316
ring
ASTM B575 (Hastelloy C-276 equivalent)
S
C
Titanium
K
Zirconium
H
Tantalum
T
Platinum
P
VI Wiring
G1/2 internal thread
connection G1/2 internal thread with plastic water-tight gland
A
B
G1/2 internal thread with brass Ni-plated water-tight gland
C
1/2NPT internal thread
D
CM20 internal thread
E
VII Face-to-face Standard
dimension Azbil Corporation's SMT3000 wafer type
A
S
VIII Calibration Standard calibration
J
IX Approval/ None
Certification FM approval, NI for Class I, II, III, Division 2, Groups A, B, C, D, F & G, T4
*3
CSA certification, Class I, II, III, Division 2, Groups A, B, C, D, E, F & G, T4
- 11 -
X
2
Options
I Diameter
-
No. SS2-MTG300-0100
Azbil Corporation
DIMENSIONS
All dimensions are in millimeters, dimensions in brackets () are in inches (inch).
Model MTG18A - Flange type size 2.5 mm (0.1 inch) to 15 mm (1/2 inch)
- Flange type size 25 mm (1 inch)
(5.33)
(5.35)
Flange type
(3.37)
Name plate
(1.97)
Size 2.5 mm to 15 mm
(0.1 inch to 1/2 inch)
(2.76) (0.98)
(
(10.63)
4.41)
(5)
(1.85)
M4 Grounding
terminal
Grounding ring
(2.83)
(2.80)
Case
(0.08)
Flange
Electrode
L
Refer to Note 1
(
)
( 0.35 ( 2))
(3.54)
(4.33)
Terminal
(5.33)
(5.35)
Name plate
Symbol
(3.37)
(1.97)
(1.85)
Grounding
Pulse output or
contact output
(selectable)
(2.76) (0.98)
( 4.41)
(5)
(3.03)
Case
Description
Flow rate
signal
M4 Grounding
terminal
Grounding
ring
Flange type
Size 25 mm
(1 inch )
Flange
(7.87)
Electrode
Refer to Note 1
Note 1 • When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension.
• When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to
the face-to-face dimension.
Table 1
Size mm
(inch)
2.5 to 10
(0.1 to3/8)
15
(1/2)
25
(1)
Model no.
Flange rating
Dimension L
Weight
(kg)
Dimension L
Weight
(kg)
H
Dimension
H1
Weight
(kg)
J1
J2
J3
10K
20K
30K
160
6.8
200
7
267
63
9.2
160
7
200
7.2
267
63
9.5
160
8
200
8.2
269
65
10.3
J4
J5
A1
A2
D1/D2 D3/D4
DIN
10K
20K
150
300
PN 10/16 PN 25/40
160
6.7
200
6.9
-
160
6.8
200
7
-
160 (6.3)
6.4 (14.1 lb)
200 (7.87)
6.6 (14.6 lb)
258 (10.16)
54 (2.13)
8.4 (18.5 lb)
160 (6.3)
6.9 (15.2 lb)
200 (7.87)
7.1 (15.7 lb)
266 (10.47)
62 (2.44)
9.5 (20.9 lb)
JIS
ANSI
10 mm flange 10 mm flange
- 12 -
160
6.9
200
7.1
262
58
9.1
160
7.1
200
7.3
262
58
9.4
Azbil Corporation
No. SS2-MTG300-0100
Model MTG18A - Flange type size 40 mm (1½ inch) to 100 mm (4 inches)
(5.33)
(5.35)
Name plate
(3.37)
(1.97)
(2.76)
( 4.41)
(5)
(0.98)
(1.85)
M4 Grounding
terminal
H2
Case
Grounding
ring
Flange
L
Electrode
Refer to Note 1
Symbol
Description
Flow rate
signal
Flange type
Grounding
Pulse output or
contact output
(selectable)
Terminal
Size 40 mm to 100 mm
(11/2 inch to 4 inches)
Note 1 • When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension.
• When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to
the face-to-face dimension.
Table 2
Size mm
(inches)
40
(1.5)
Model no.
Flange rating
Dimension
Weight
50
(2)
Dimension
Weight
65
(2.5)
Dimension
Weight
80
(3)
Dimension
Weight
100
(4)
J1
Dimension
Weight
L
H
H1
H2
(kg)
L
H
H1
H2
(kg)
L
H
H1
H2
(kg)
L
H
H1
H2
(kg)
L
H
H1
H2
(kg)
10K
200
296
85
84
8.3
200
310
90
93
11.9
200
329
102
100
13.9
200
345
110
108
14.4
250
367.5
120
120.5
20.2
J2
JIS
20K
200
296
85
84
8.6
200
310
90
93
12
200
329
102
100
14
200
354
119
108
16.7
250
376.5
129
120.5
23.7
J3
A1
A2
D1/D2
ANSI
30K
200
307
96
84
11
200
316
96
93
13.7
200
343
116
100
15.7
200
359
124
108
20.4
250
384.5
137
120.5
28.6
150
200 (7.87)
288 (11.34)
77 (3.03)
84 (3.31)
7.8 (17.2 lb)
200 (7.87)
308 (12.13)
88 (3.46)
93 (3.66)
12.3 (27.1 lb)
200 (7.87)
330 (12.99)
103 (4.06)
100 (3.94)
14.3 (31.5 lb)
200 (7.87)
346 (13.62)
113 (4.45)
108 (4.25)
17.3 (38.1 lb)
250 (9.84)
378.5 (14.90)
131 (5.16)
120.5 (4.74)
25.1 (55.3 lb)
- 13 -
D3/D4
DIN
300
200 (7.87)
305 (12.01)
94 (3.7)
84 (3.31)
10.1 (22.3 lb)
200 (7.87)
316 (12.44)
96 (3.78)
93 (3.66)
13.8 (30.4 lb)
200 (7.87)
388 (13.31)
111 (4.37)
100 (3.94)
15.8 (34.8 lb)
200 (7.87)
359 (14.13)
124 (4.88)
108 (4.25)
21.3 (47.0 lb)
250(9.84)
392.5 (15.45)
145 (5.71)
120.5 (4.74)
34.2 (75.4 lb)
PN 10/16
200
302
91
84
8.7
200
316
96
93
13.3
200
334
107
100
15.3
200
354
119
108
14.4
250
373.5
126
120.5
19.6
PN 25/40
200
302
91
84
9.7
200
316
96
93
13.8
200
334
107
100
15.8
200
354
119
108
16.5
250
381.5
134
120.5
23.4
No. SS2-MTG300-0100
Azbil Corporation
Model MTG18A - Flange type size 150 mm (6 inches) and 200 mm (8 inches)
(5.33)
(5.35)
(1.97)
(3.37)
(2.76) (0.98)
( 4.41)
(5)
(1.85)
Case
H2
M4 Grounding
terminal
Grounding
ring
Flange
Electrode
L
Refer to Note 1
Symbol
Description
Flow rate
signal
Flange type
Grounding
Pulse output or
contact output
(selectable)
Size 150 mm and 200 mm
(6 inches and 8 inches)
Terminal
Note 1 • When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension.
• When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to
the face-to-face dimension.
Table 3
Size mm
(inches)
Model no.
Flange rating
Dimension
150
(6)
200
(8)
L
H
H1
H2
Weight
(kg)
Dimension L
H
H1
H2
Weight
(kg)
J1
10K
300
462
175
160
34.4
350
508
196
185
49.8
J2
JIS
20K
300
476
189
160
41.7
350
515
203
185
59.8
J3
A1
A2
D1/D2
ANSI
30K
150
300
PN 10/16
300
300 (11.81)
300 (11.81)
300
487
461 (18.15)
483 (19.02)
465
200
174 (6.85)
196 (7.72)
178
160
160 (6.3)
160 (6.3)
160
54.3 37.2 (82.0 lb) 56.2 (123.9 lb)
30.7
350
350 (13.78)
350 (13.78)
350
531
516 (20.31)
537 (21.14)
514
219
204 (8.03)
225 (8.86)
202
185
185 (7.28)
185 (7.28)
185
87 61.8 (136.2 lb) 90.8 (200.2 lb)
48.1
- 14 -
D3
DIN
PN 25
300
473
186
160
38.6
350
526
214
185
68.5
D4
PN40
300
473
186
160
38.6
350
534
222
185
72
Azbil Corporation
No. SS2-MTG300-0100
Model MTG18A - Wafer type size 25 mm (1 inch) to 100 mm (4 inches)
(5.33)
Name plate
(5.35)
(3.37)
(1.97)
H
(2.76)
(0.98)
( 4.41)
(5)
(1.85)
Case
M4 grounding
terminal
(H1)
H2
D
Grounding
ring
L
Electrode
Refer to note1
Symbol
Description
Flow rate
signal
Wafer type
Grounding
Pulse output or
contact output
(selectable)
Terminal
Size 25 mm and 100 mm
(1 inch and 4 inches)
Note 1 • When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension.
• When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to
the face-to-face dimension.
Table 4
Flange rating
Face-to-face
dimension code
L
Dimension
size
Weight
25 mm
(1 inch)
A
40 mm
(1½ inch)
A
S
50 mm
(2 inches)
A
S
65 mm
(2½
inches)
A
80 mm
(3 inches)
A
S
100 mm
(4 inches)
A
S
94 (3.7) 80 (3.15) 98 (3.86) 86 (3.39) 104 (4.09) 96 (3.78) 106 (4.17) 130 (5.12) 120 (4.72) 150 (5.91)
H
238 (9.37)
254.5 (10.02)
272 (10.71)
289 (11.38)
302 (11.89)
327 (12.87)
H1
34 (1.34)
43.5 (1.71)
52 (2.05)
62 (2.44)
67 (2.64)
79.5 (3.13)
H2
77 (3.03)
84 (3.31)
93 (3.66)
100 (3.94)
108 (4.25)
120.5 (4.74)
D
68 (2.68)
87 (3.43)
104 (4.09)
124 (4.88)
134 (5.28)
159 (6.26)
(kg)
3.7
(8.2 lb)
3.8
4.3
4.4
5.0
(8.4 lb) (9.5 lb) (9.7 lb) (11.0 lb)
- 15 -
5.5
(12.1 lb)
6.4
7.1
8.2
9.2
(14.1 lb) (15.7 lb) (18.1 lb) (20.3 lb)
No. SS2-MTG300-0100
Azbil Corporation
Model MTG14C - Converter
(4.41)
(0.13)
(10.12)
(R0.31)
(3.63)
Plate
(10.67 +0.040 )
(R0.49)
(R0.49)
(2.91+0.02)
(0.63)
(R0.49)
(0.77)
(0.75)
(R0.16)
(1.77)
(1.19 max.)
Wall mounting dimension
(1.77)
(9.92)
(2.74)
(4.36)
Wall mounting
(4.41)
(3.63)
Grounding
Pulse output
or contact
(selectable)
Excitation output
Flow rate
signal input
(1.77)
(1.77)
(4.92)
* Terminal screw: M4
(6.30)
PULSE/
STATUS
OUT
X
Y
A
B
C
Flow rate signal
(1.19 max.)
I-OUT
Description
(0.63)
Symbol
(10.12)
Terminal
(2.74)
(4.36)
2-inch pipe mounting
(1.23)
Model SMC11 - Cable
Wiring diagram
Detector
A
C
B
X
Y
L
Cable
Converter
A
C
B
X
Y
Note) Grounding resistance: 100W max.
L: Cable length
- 16 -
Azbil Corporation
No. SS2-MTG300-0100
Model MTG18B - Detector - Flange type size 10 mm (3/8 inch) and 15 mm (1/2 inch)
- Flange type size 25 mm (1 inch)
Blind plug
(1.19 max.)
(3.31)
(1.85)
(0.98)
(3.31)
Waterproof gland
(optional)
Size 10 mm and 15 mm
(3/8 and 1/2 inch)
Tag plate
(2.80)
Nameplate
Grounding ring
(0.08)
(2.83)
(7.48)
Flange type
Terminal box
(3.54)
(4.43)
(2.05)
Electrode
9 ( 2)
( 0.35 ( 2))
Refer to note 1
(4.43)
Terminal
Blind plug
(1.19 max.)
(3.31)
(1.85)
(0.98)
Symbol
(3.31)
Terminal box
Waterproof gland
(optional)
Tag plate
Nameplate
(3.03)
Description
X
Y
A
B
C
Grounding ring
Excitation input
Flow rate signal
output
H
Grounding
H1
* Terminal screw: M4
Flange type
(7.89)
Electrode
Refer to note 1
Size 25 mm (1 inch)
Note 1 • When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension.
• When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to
the face-to-face dimension.
Table 5
Model no.
Size mm
(inches)
J1
J2
J3
J4
J5
A1
JIS
Flange rating
10
(3/8)
Dimension
15
(1/2)
Dimension
25
(1)
Dimension
Weight
Weight
Weight
10K 20K 30K
A2
D1/D2
ANSI
DIN
10K
20K
150
300
160 (6.3)
160 (6.3)
10 mm flange 10 mm flange
L
160
160
160
160
160
(kg)
5
5.2
6.2
4.9
5
L
200
200
200
200
200
(kg) 5.2
5.4
6.4
5.1
5.2
4.6 (10.1 lb) 5.1 (11.2 lb)
200 (7.87)
D3/D4
200 (7.87)
4.8 (10.6 lb) 5.3 (11.7 lb)
PN 10/16 PN 25/40
160
160
5.1
5.3
200
200
5.3
5.5
H
187
187
189
-
-
188 (7.4)
186 (7.32)
182
182
H1
63
63
65
-
-
54 (2.13)
62 (2.44)
58
58
(kg) 7.4
7.7
8.5
-
-
7.3
7.6
- 17 -
6.6 (14.6 lb) 7.7 (17.0 lb)
No. SS2-MTG300-0100
Azbil Corporation
Model MTG18B - Detector - Flange type size 40 mm (1½ inch) to 100 mm (4 inches)
(1.19 max.)
(3.31)
Blind plug
(3.31)
Waterproof gland
(optional)
Tag plate
(1.85)
(0.98)
Terminal box
Nameplate
H2
Case
Grounding
ring
Flange
L
Electrode
Refer to Note 1
Symbol
X
Y
A
B
C
Description
Excitation input
Flow rate signal
output
Flange type
Grounding
Size 40 mm to 100 mm
(11/2 inch to 4 inches)
* Terminal screw: M4
Terminal
Note 1 • When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension.
• When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to
the face-to-face dimension.
Table 6
Size mm
(inches)
40
(1.5)
Model no.
Flange rating
Dimension
Weight
50
(2)
Dimension
Weight
65
(2.5)
Dimension
Weight
80
(3)
Dimension
Weight
100
(4)
J1
Dimension
Weight
L
H
H1
H2
(kg)
L
H
H1
H2
(kg)
L
H
H1
H2
(kg)
L
H
H1
H2
(kg)
L
H
H1
H2
(kg)
10K
200
216
85
84
6.5
200
230
90
93
10.1
200
249
102
100
12.1
200
265
110
108
16.6
250
287.5
120
120.5
18.4
J2
JIS
20K
200
216
85
84
6.8
200
230
90
93
10.2
200
249
102
100
12.2
200
274
119
108
14.9
250
296.5
129
120.5
21.9
J3
A1
A2
D1/D2
ANSI
30K
200
227
96
84
9.2
200
236
96
93
11.9
200
263
116
100
13.9
200
279
124
108
18.6
250
304.5
137
120.5
26.8
- 18 -
150
200 (7.87)
208 (8.19)
77 (3.03)
84 (3.31)
6 (13.2 lb)
200 (7.87)
228 (8.98)
88 (3.46)
93 (3.66)
10.5 (23.1 lb)
200 (7.87)
250 (9.84)
103 (4.06)
100 (3.94)
12.5 (27.6 lb)
200 (7.87)
266 (10.47)
113 (4.45)
108 (4.25)
15.5 (34.2 lb)
250 (9.84)
298.5 (11.75)
131 (5.16)
120.5 (4.74)
23.3 (51.4 lb)
D3/D4
DIN
300
200 (7.87)
225 (8.86)
94 (3.7)
84 (3.31)
8.3 (18.3 lb)
200 (7.87)
236 (9.29)
96 (3.78)
93 (3.66)
12 (26.5 lb)
200 (7.87)
258 (10.16)
111 (4.37)
100 (3.94)
14 (30.9 lb)
200 (7.87)
279 (10.98)
124 (4.88)
108 (4.25)
19.5 (43.0 lb)
250 (9.84)
312.5 (12.30)
145 (5.71)
120.5 (4.74)
32.4 (71.4 lb)
PN 10/16
200
222
91
84
6.9
200
236
96
93
11.5
200
254
107
100
13.5
200
274
119
108
12.6
250
293.5
126
120.5
17.8
PN 25/40
200
222
91
84
7.9
200
236
96
93
12
200
254
107
100
14
200
274
119
108
14.7
250
301.5
134
120.5
21.6
Azbil Corporation
No. SS2-MTG300-0100
Model MTG18B - Detector - Flange type size 150 mm (6 inches) and 200 mm (8 inches)
(3.31)
Blind plug
(3.31)
Terminal box
Tag plate
(1.85)
(0.98)
(1.19 max.)
Waterproof gland
(optional)
Nameplate
H2
Case
Grounding
ring
Flange
Electrode
L
Refer to Note 1
Symbol
X
Y
A
B
C
Description
Excitation input
Flow rate signal
output
Flange type
Size 150 mm and 200 mm
(6 inches and 8 inches)
Grounding
* Terminal screw: M4
Terminal
Note 1 • When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension.
• When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to
the face-to-face dimension.
Table 7
Size mm
(inches)
150
(6)
Model no.
Flange rating
Dimension
Weight
200
(8)
J1
Dimension
Weight
J2
J3
A1
JIS
A2
D1/D2
ANSI
D3
D4
DIN
10K
20K
30K
150
300
L
300
300
300
300 (11.81)
300 (11.81)
300
300
300
H
382
396
407
381 (15)
403 (15.87)
385
393
393
H1
175
189
200
174 (6.85)
196 (7.72)
178
186
186
H2
160
160
160
160 (6.3)
160 (6.3)
160
160
160
(kg)
32.6
39.9
52.5
35.4 (78 lb)
54.4 (119.9 lb)
28.9
36.8
36.8
L
350
350
350
350 (13.78)
350 (13.78)
350
350
350
H
428
435
451
436 (17.17)
457 (17.99)
434
446
454
H1
196
203
219
204 (8.03)
225 (8.86)
202
214
222
H2
185
185
185
185 (7.28)
185(7.28)
185
185
185
(kg)
48
58
85.2
60 (132.3 lb)
89 (196.2 lb)
46.3
66.7
70.2
- 19 -
PN 10/16 PN 25
PN 40
No. SS2-MTG300-0100
Azbil Corporation
Model MTG18B - Detector - Wafer type size 25 mm (1 inch) to 100 mm (4 inches)
(1.19 max.)
(3.31)
(0.98)
Terminal box
Waterproof gland
(optional)
Tag plate
(1.85)
Blind plug
(3.31)
Nameplate
Grounding ring
D
Electrode
Refer to Note 1
Description
Symbol
X
Y
A
B
C
Excitation input
Flow rate signal
output
Wafer type
Grounding
Size 25 mm to 100 mm
(1 inch to 4 inches)
* Terminal screw: M4
Terminal
Note 1 • When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension.
• When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to
the face-to-face dimension.
Table 8
Flange rating
Face-to-face
dimension code
L
H
DimenH1
sion size
H2
D
Weight
25 mm
(1 inch)
A
40 mm
(1½ inch)
A
S
50 mm
(2 inches)
A
S
94 (3.7) 80 (3.15) 98 (3.86) 86 (3.39) 104 (4.09)
158 (6.22)
174.5 (6.87)
192 (7.56)
34 (1.34)
43.5 (1.71)
52 (2.05)
77 (3.03)
84 (3.31)
93 (3.66)
68 (2.68)
87 (3.43)
104 (4.09)
2
2
2.5
2.6
3.2
(kg)
(4.4 lb) (4.4 lb) (5.5 lb) (5.7 lb) (7.1 lb)
65 mm
(2½ inches)
A
80 mm
(3 inches)
A
S
100 mm
(4 inches)
A
S
96 (3.78) 106 (4.17) 130 (5.12) 120 (4.72) 150 (5.91)
209 (8.23)
222 (8.74)
247 (9.72)
62 (2.44)
67 (2.64)
79.5 (3.13)
100 (3.94)
108 (4.25)
120.5 (4.74)
124 (4.88)
134 (5.28)
159 (6.26)
3.7
4.6
5.3
6.4
7.4
(8.2 lb) (10.1 lb) (11.7 lb) (14.1 lb) (16.3 lb)
Please read the "Terms and Conditions" from the following URL before
ordering or use:
http://www.azbil.com/products/bi/order.html
Specifications are subject to change without notice.
1-12-2 Kawana, Fujisawa
Kanagawa 251-8522 Japan
URL: http://www.azbil.com/
- 20 (10)
1st Edition: Issued in May 2010
2nd Edition: Issued in June 2012
No part of this publication may be reproduced or duplicated
without the prior written permission of Azbil Corporation.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement