- No category
advertisement
▼
Scroll to page 2
of 20
No. SS2-MTG300-0100 MagneW Two-wire PLUS+ Smart Two-wire Electromagnetic Flowmeter Model MTG18A (Integral type) Model MTG14C/MTG18B (Remote type) OVERVIEW The MagneW Two-wire PLUS+ is a high performance electromagnetic flowmeter based on field proven Azbil Corporation's two-wire loop powered technology. The MagneW Twowire PLUS offers the stable and accurate measurement of a traditional magflow meter with low power consumption. The result is a lower overall cost of ownership. FEATURES Two-wire operation MagneW Two-wire PLUS+ improves its noise immunity performance by 700% maximum and 250% in average. For the spike noise, MagneW Two-wire PLUS+ improves its noise immunity performance in 250% in average. High accuracy and stable output MagneW Two-wire PLUS+ provides high accuracy (± 0.5% of rate) and its output is as stable as current four wired magnetic flowmeters. Minimum measurable fluid conductivity The MagneW Two-wire PLUS+ offers a minimum process fluid conductivity of 10μS/cm which is the best among two-wire magflow meters thereby maximizing applicability. Wider range in size MagneW Two-wire PLUS+ offers wider range in detector size. Detector size: 2.5 to 200 mm. Wafer and flange style, integral and remote style available The MagneW Two-wire PLUS+ is available integral or remote, flanged or wafer, making the selection of the right meter for the application simple. Electrode status diagnostic function The MagnoW Two-wire PLUS+ offers the Integral type Remote type diagnostic function for the electrode condition. It diagnoses the Empty pipe condition or scale on electrode condition. APPLICATIONS • Corrosive liquid measurement • Chemical solution measurement • Drainage/waste disposal fluid measurement • Drinking water and waste water service • Industrial/agricultural water measurement • Seawater measurement -1- 2nd Edition No. SS2-MTG300-0100 Azbil Corporation FUNCTIONAL SPECIFICATIONS EU Pressure Equipment Directive (97/23/ EC) Model MTG18A and MTG18B are in accordance with SEP category (Article 3, paragraph 3). Enclosure rating NEMA TYPE 4X, IEC IP67 Hazardous Areas certifications for dangerous liquids Integral type FM approval <for Division 1> Class I, Division 1, Groups A, B, C & D, T4; Class II, Division 1, Groups E, F & G, T4; Class III, T4, -20°C < Tamb < +60°C <for Division 2> Nonincendive for Class I, Division 2, Groups A, B, C & D, T4; Class II, Division 2, Groups F & G, T4; Class III, T4; Class I, Zone 2, Group IIC, T4, -20°C < Tamb < +60°C CSA certification <for Division 1> Class I, Division 1, Groups A, B, C & D, T4; Class II, Division 1, Groups E, F & G, T4; Class III, T4, -20°C < Tamb < +60°C <for Division 2> Class I, Division 2, Groups A, B, C, & D, T4; Class II, Division 2, Groups E, F & G, T4; Class III, T4, -20°C < Tamb < +60°C ATEX(KEMA) Certification <for Type n> DN Maximum Pressure Less than 65mm 30bar 80mm 25bar 100mm 20bar 150mm 13bar 200mm 10bar for non dangerous liquids The maximum process pressure is 30bar for all sizes. Output signal Analog output 4 to 20 mA DC Digital output DE Analog or Digital output is selectable. Pulse output Open collector output (30V DC, 100 mA max.) Pulse frequency: 0.0001 to 200 Hz Pulse width: 1 ms to 1 s LOW value: 2.7V (10mA) (Refer to the blow drawing.) HIGH II 3 GD 2.7V LOW Ex nA II T6 T135ºC at Tprocess: -40...+85ºC Ex nA II T5 T135ºC at Tprocess: -40...+100ºC Ex nA II T4 T135ºC at Tprocess: -40...+130ºC -40ºC < Tamb < +60ºC KEMA 07ATEX0066 IP66/67 0V Contact output Open collector output (30V DC, 100 mA max.) Pulse or contact output is selectable Communication protocol SFC communication and HART communication NEPSI Certification <for Type n> Ex nA II T6 DIP A21 TA 135ºC at Tprocess=85ºC Ex nA II T5 DIP A21 TA 135ºC at Tprocess=100ºC Ex nA II T4 DIP A21 TA 135ºC at Tprocess=130ºC -40ºC < Tamb < +60ºC Remote type FM approval <for Division 2> Nonincendive for Class I, Division 2, Groups A, B, C & D, T4; Class II, Division 2, Groups F & G, T4; Class III, T4; Class I, Zone 2, Group IIC, T4, -20°C < Tamb < +60°C CSA certification <for Division 2> Class I, Division 2, Groups A, B, C & D, T4; Class II, Division 2, Groups E, F & G, T4; Class III, T4, -20°C < Tamb < +60°C HART® communication • Multidrop mode: current fixed at 12mA Optional Burst mode is not available. Load resistance characteristic of communication External power supply 21.05 to 42V DC for communication. Load resistance (Ω) 2 1 21.05<V<30 R= V-15.6 0.0218 2 30<V<42 R= V-14.25 0.02383 1 Power supply (V DC ) Note) The load resistance of 250 Ω or more is necessary for communications of SFC and the HART communicator. -2- Azbil Corporation No. SS2-MTG300-0100 Flow unit The Electrode status diagnostic function makes the analog output and pulse output to the values as selected in the below "Electrode status output mode" table. The display alternately shows the output values selected and "EMPTY OR SCALE ON ELECTRODE". There are five threshold levels to meet an environment where the device is installed. Set an appropriate threshold level from below. SENSITIVITY HIGH SENSITIVITY MID SENSITIVITY LOW SENSITIVITY LL SENSITIVITY LLL Default setting: OFF Operating condition: The following conditions must be met when using the electrode status diagnostic function. • Diameter: 10mm or larger Volume flow:m³, L, cm³, G (gallon), mG, kG, B (barrel), IG (imperial gallon), mIG, kIG Mass flow: t, kg, g, lb Time: d, h, min., s Display Display: LCD Main display: 7-segment, 8 digits Sub display: 16 digits, 2 lines Display contents: Simultaneously displays % flow rate, Actual flow rate (eng. unit) and Totalized value. Data setting Operation by four key switches Damping Adjustable between 0.5 and 199.9 seconds. Low flow cutoff Adjustable between 0 and 10% of setting range. Below selected value, output is driven to the zero flow rate signal level. • Electric conductivity of fluid: 30 μS/cm or greater • Grounding: Grounding resistance must be less than 100Ω Dropout Adjustable between 0 and 10% of setting range. Below selected value, pulse output is cut. • The noise level must be over the set threshold when the pipe is empty. Electrode status diagnotic • The noise level must be under the set threshold when the process fluid flows in the detector. Detect empty pipe condition or scale on electrode condition by monitoring flow rate signal. Once the flow rate signal fluctuates over a certain threshold, the device judges that the detector is empty or scale appears on the electrode. “Electrode status output mode” table” Output/Display Analog 4 – 20mA output Pulse output Display Parameter selection in the “Electrode status output mode” OFF Output values as the meter measures. Output values as the meter measures. Display the value as it measures. ZERO HOLD Analog output is fixed to 0% (4mA). Analog output is held at its last good value. Pulse output is fixed to 0 (does not Pulse output is held at generate pulses). its present state. Flashes the message 0% and “Empty Flashes the values at its last good values and a or scale on electrode” alternately message of “Empty or (when % flow rate is specified for scale on electrode” the main display). alternately. Flashes the message 0.000 RATE and “Empty or scale on electrode” alternately (when actual flow rate is specified for the main display). Flashes the message XXXXXXXX (totalized value at setup) and “Empty or scale on electrode” alternately (when totalized value is specified for the main display). -3- No. SS2-MTG300-0100 Azbil Corporation Lightning protection 10, 15, 25, 40, 50, 65, 80, 100, 150, 200 mm (3/8, 1/2, 1, 1½, 2, 2½, 3, 4, 6, 8 inches) 12 kV, 1000A Equipped with the lightning arrester in the power source and external output terminals. Flange rating ANSI150, ANSI300, DIN PN10, DIN PN16, DIN PN25, JIS10K, JIS20K, JIS30K Power failure An EEPROM retains data record of totalized value when pulse output is used (retention period approximately 10 years). Reference flange standard JIS; JIS B2210 (1984) ANSI; ANSI B16.5 (1988) Power supply Ambient temperature limits 15.6 to 42V DC (without communication) 21.05 to 42V DC (with communication) Current capacity: 24mA min. In case of current capacity is 22mA, the voltage must be 15.6V minimum. -20 to 60°C (-4 to 140°F) Ambient humidity limits 10 to 90% RH Vibration effect Size Integral style: 4.9m/s2(0.5G) max. Remote style converter: 19.6m/s2(2G) max. Remote style detector: 19.6m/s2(2G) max. Wafer style 25, 40, 50, 65, 80, 100 mm (1, 1½, 2, 2½, 3, 4 inches) Flange style 2.5, 5 mm (0.1, 0.2 inch) (Model MTG18A only) Temperature range and pressure range of process fluid Refer to the following. Size: 2.5 to 10 mm (0.1 to 3/8 inch) Size: 15 to 200 mm (1/2 to 8 inch) 2.94 MPa (426 psi) 2.94 MPa (426 psi) 1.96 MPa (284 psi) 0.98 MPa (142 psi) -0.098 MPa (-14.2 psi) -20 C (-4 F) -0.098 MPa (-14.2 psi) -20 C (-4 F) 80 C 100 C (176 F)(212 F) 80 C 120 C 130 C (176 F) (248 F) (266 F) Measurable electrical conductivity 10 μS/cm or greater 50 μS/cm or greater (10 mm (3/8 inch), 15 mm (1/2 inch) for remote type) Measurement flow range Size Maximum flow velocity range is 0 to 0.3 m/s (0 to 0.98 ft/s) Maximum flow velocity range is 0 to 10 m/s (0 to 32.8 ft/s) Minimum range Maximum range Conversion factor K mm inches m3/h GPM m3/h GPM 2.5 0.1 0 to 0.00531 0 to 0.02335 0 to 0.1767 0 to 0.778 56.59 5 0.2 0 to 0.02121 0 to 0.09337 0 to 0.7068 0 to 3.112 14.15 10 3/8 0 to 0.08483 0 to 0.3735 0 to 2.827 0 to 12.44 3.537 15 1/2 0 to 0.1909 0 to 0.8404 0 to 6.361 0 to 28.00 1.572 25 1 0 to 0.5302 0 to 2.335 0 to 17.67 0 to 77.80 0.5659 40 1½ 0 to 1.358 0 to 5.976 0 to 45.23 0 to 199.1 0.2210 50 2 0 to 2.121 0 to 9.337 0 to 70.68 0 to 311.2 0.1415 65 2½ 0 to 3.584 0 to 15.78 0 to 119.4 0 to 525.9 0.08371 80 3 0 to 5.429 0 to 23.91 0 to 180.9 0 to 796.7 0.05526 100 4 0 to 8.483 0 to 37.35 0 to 282.7 0 to 1244 0.03537 150 6 0 to 19.09 0 to 84.04 0 to 636.1 0 to 2800 0.01572 200 8 0 to 33.93 0 to 149.4 0 to 1130 0 to 4979 0.008842 Velocity V (m/s) = K × Q K = Conversion factor = 1/3600 × 4/(πD²) × 1000², D = Size (mm), Q = Flow rate (m³/h) -4- Azbil Corporation No. SS2-MTG300-0100 PERFORMANCE SPECIFICATIONS Size 25 to 200 mm (1 to 8 inches): SUS304 stainless steel Measuring pipe material SUS304 stainless steel Analog output accuracy Size: 2.5, 5 mm (0.1, 0.2 inch) Vs = velocity of setting range (m/s) Vs (m/s) Velocity during measurement > Vs×50% Velocity during measurement < Vs×50% 1.0 ≤ Vs ≤ 10 ±0.5% of rate ±0.5% of Vs 0.3 ≤ Vs ≤ 1.0 ± ------- % of rate 0.5 Vs Flange SUS304 stainless steel (size 2.5 to 65 mm (0.1 to 2½ inches)) Carbon steel + corrosion-preventive painting (size 80 to 200 mm (3 to 8 inches)) 0.5 ± 0.5 + ⎛ -------⎞ % of Vs ⎝ Vs ⎠ Process wetted materials Lining: PFA Electrodes SUS316L, ASTM B574 (Hastelloy C-276 equivalent), Titanium, Tantalum, Nickel, Zirconium, PlatinumIridium Grounding rings SUS316, ASTM B575 (Hastelloy C-276 equivalent), Titanium, Tantalum, Zirconium, Platinum Size: 10, 15 mm (3/8, 1/2 inch) Vs = velocity of setting range (m/s) Vs (m/s) Velocity during measurement > Vs×40% Velocity during measurement < Vs×40% 1.0 ≤ Vs ≤ 10 ±0.5% of rate ±0.5% of Vs 0.3 ≤ Vs ≤ 1.0 ± ------- % of rate 0.5 Vs 0.5 -⎞ % of Vs ± 0.4 + ⎛⎝ -----Vs ⎠ Size: 25 to 200 mm (1 to 8 inches) INSTALLATION Vs = velocity of setting range (m/s) Vs (m/s) Velocity during measurement > Vs×30% Velocity during measurement < Vs×30% 1.0 ≤ Vs ≤ 10 ±0.5% of rate ±0.5% of Vs 0.3 ≤ Vs ≤ 1.0 ± ------- % of rate 0.5 Vs Electrical connection 1/2NPT internal thread (must be selected for FM approval) CM20 internal thread G1/2 internal thread Remote converter mounting 0.5 ± 0.3 + ⎛⎝ -------⎞⎠ % of Vs Vs Wall mounting, 2-inch pipe mounting Grounding Accuracy is guaranteed by the totalized flow volume under the condition of continuous flow measurement for 30 seconds or longer. The grounding is essential for flow measurement. The most effective grounding method is direct connection to earth ground with minimal impedance. For approval selection code “1”, to maintain Intrinsic safety of system connect conductor to earth ground so that it has less than 1 Ohm to earth ground. See ANSI/ISA RP12.06.01 Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations for guidance on installation of intrinsically safe apparatus and systems. PHYSICAL SPECIFICATIONS Converter case finishing Standard Baked acrylic paint Corrosion-proof Baked epoxy paint Pipe connection Converter case material Aluminum alloy Wafer style (Size: 25 to 100 mm (1 to 4 inches)) Flange style (Size: 2.5 to 200 mm (0.1 to 8 inches)) Display cover material Length of straight pipe Tempered glass Required straight pipe length clearance on the upstream side and the downstream side, while installing the detector. Upstream side A minimum 5D straight pipe length is required. A minimum 10D straight pipe length is required if a diffuser/valve/pump is installed upstream side. Downstream side 2D straight pipe length is recommended. (Where D is the nominal bore diameter of the detector) Terminal box finishing (Model MTG18B only) Standard: Baked acrylic paint Corrosion-proof: Baked epoxy paint Terminal box material (Model MTG18B only) Aluminum alloy Detector main body materials Case material Size 2.5 to 15 mm (0.1 to 1/2 inch): SCS13 stainless steel -5- No. SS2-MTG300-0100 Azbil Corporation Cable between converter and detector Upstream side Right-angle joint Diffuser with cone angle greater than 15 detector (If cone angle is 15 or less, considered as straight pipe) (Remote type) Length 70 m (233 ft) or shorter (25 mm (1 inch) to 200 mm (8 inches)) 30 m (98 ft) or shorter (10 mm (3/8 inch), 15 mm (1/2 inch)) Outside diameter 11.4 mm (0.45 inch) detector Greater than 5 dia. Greater than 10 dia. Greater than 5 dia. Gate Value (completely open) detector Greater than 5 dia. Maximum cable length of SMC11 cable detector Process fluid conductivity [ S/cm] detector T joint Concentrator (considered as straight-pipe section) Greater than 5 dia. Any Control Value detector Greater than 10 dia. Any pump P Size 10mm, 15mm Size 25mm or larger 50 10 2m 30m 70m Cable length [m] Greater than 10 dia. Figure 2 Maximum cable length of SMC11 cable Figure 1 -6- Azbil Corporation No. SS2-MTG300-0100 Notice for installation Example: Sodium hypochlorite with 200V and 30kA Four wire magnetic flowmeter is recommended. • Application which pipe frequently becomes empty Both two wire magnetic flowmeter and four wire magnetic flowmeter have empty pipe detection function. The two wire magnetic flowmeter detects empty by monitoring signal fluctuation caused by empty pipe condition. Therefore the empty pipe detection function of the two wire magnetic flowmeter sometimes does not work properly if noise level is too low or too high. The four wire magnetic flowmeter detects empty by monitoring impedance between electrodes and grounding. So the four wire magnetic flowmeter directly monitors the empty pipe condition. If the application requires empty detection quickly and perfectly, the four wire magnetic flowmeter is recommended. • Plastic piping or piping with liner If the customer piping is plastic or lined with insulation material, process fluid may not be properly grounded. In such case, it is recommended to connect earth wire between upstream side grounding ring and downstream side grounding ring for better grounding. • Slurry application Process fluid with slurry exceeds 3% is not suitable for the two wire magnetic flowmeter. The four wire magnetic flowmeter is recommended for the fluid with slurry concentration more than 3%. If hard particles hit the electrode, output of the two wire magnetic flowmeter may fluctuate even though the slurry concentration is less than 3%. In this case, the four wire magnetic flowmeter is recommended. • Electrochemically homogeneous fluid Install the device where the process fluid is electrochemically homogeneous. If two kind of process fluids are mixed at the upstream side, the process fluid must be uniformly mixed. • The application which the electric conductivity changes or non-homogeneous fluid Do not use the device for the following fluid conditions even if the electric conductivity, temperature, and pressure are within the device specifica- To fully enjoy the performance of the device, please choose an appropriate location according to the following. Notice after installation WARNING When removing the device from the piping, make sure that there is no line pressure or process fluid inside of the device. Removing the device before depressurizing may result in serious injury. CAUTION Do not use the device as a foothold. It may cause injury or damage of the device. Notice for environment • Install the flowmeter in a location with an ambient temperature of -25°C to 60°C (-13°F to 140°F) and an ambient humidity of 5 to 100%RH to prevent equipment malfunction or output errors. • Do not install the flowmeter in a location subject to severe vibration or in a highly corrosive atmosphere. The converter and detector can be damaged. * When install some electromagnetic flowmeters in closer location, keep minimum 500mm (20 inch) space from each flowmeter. Closer electromagnetic flowmeter installation may cause magnetic interference each other and results in output errors. • Do not install the flowmeter in a location subject to severe vibration or in a highly corrosive atmosphere. The converter and detector can be damaged. • When install some electromagnetic flowmeters in closer location, keep minimum 500mm (20 inch) space from each flowmeter. Closer electromagnetic flowmeter installation may cause magnetic interference each other and results in output errors. Notice for application • Electrolytic bath application, process fluid with higher voltage/current Process fluid of the electrolytic bath application is mostly with high voltage/current. It is not a suitable application for the two wire loop powered magnetic flowmeter. -7- No. SS2-MTG300-0100 Azbil Corporation tions. Those fluid may cause of inaccurate flow measurement. • Fluids that have sufficient conductivity at high temperature but do not meet the conductivity requirement at room temperature (about 20ºC (68ºF)). (e.g. fatty acids and soap) • Some fluids contain surfactant (e.g. rinse, shampoo and CWM (coal water mixture)) • Insulating adhesive materials (e.g. kaolinite, kaolin, calcium stearate) • The analog output may fluctuate due to flow noise, which is generated by the process fluid flow. In such a case, connect the upstream grounding ring to the downstream grounding ring by a wire. The output fluctuation may be reduced. • The following fluids will permeate the PFA liner. The vent hole option is recommended for the following fluids. • Nitric acid • Aqueous ammonia • High temperature sodium hydrate Caution On PLC Connection A circuit in some PLC may affect the flow measurement and the analog output may fluctuate. In this case, make sure that the both PLC and the MagneW Two-wire PLUS+ flowmeter are properly grounded. Proper grounding solves the fluctuation problem. CAUTION In accordance with the safety standards of flameproof regulation, please comply with the following instructions.: (1) The voltage of general equipment such as the power supply and the receiver should not exceed 250VAC, 50/60Hz, 250VDC at any time at normal or abnormal operation. (2) The ambient temperature around the device is 50ºC (122ºF) maximum. (3) The process fluid temperature is 125ºC (257ºF) max. for the size of 15mm (1/2 inch) or larger. (4) The process fluid temperature is 100ºC (212ºF) max. for the size of 10mm (3/8 inch) or smaller. (5) Use the specified flameproof cable glands. (6) Wait for seven minutes after switching OFF the power supply, before opening the front cover or the terminal cover. A specified explosion-proof performance is available only when this device is used under the conditions described above. Notice for power supply • Use the following power supply. If the power supply does not meet the following specifications, this device may not work. • Current capacity: 24mA min. -8- Azbil Corporation No. SS2-MTG300-0100 MODEL SELECTION MagneW Two-wire PLUS+ Model MTG18A - I II III IV V VI VII VIII IX X XI - XII XIII - Options (some options can be selected per each model) Selections Optional selections Options MTG18A I Line size II Lining III Pipe connection 2.5 mm (0.1 inch) (flange type only) 5 mm (0.2 inch) (flange type only) 10 mm (3/8 inch) (flange type only) 15 mm (0.5 inch) (flange type only) 25 mm (1 inch) 40 mm (1½ inches) 50 mm (2 inches) 65 mm (2½ inches) 80 mm (3 inches) 100 mm (4 inches) 150 mm (6 inches) (flange type only) 200 mm (8 inches) (flange type only) PFA Wafer JIS10K Wafer JIS16/20K 002 005 010 015 025 040 050 065 080 100 150 200 *1 *1 *1 *1 X None B Traccability certificale C Material certificate (electrode/ grounding ring) G Gasket for plastic piping J Tropical treatment K with tagging on the converter housing *3 L with tag number plate wired to the flowmeter *6 P X Finish / 2 paint 11 12 Wafer JIS30K 13 Wafer ANSI 150 21 Wafer ANSI 300 22 Wafer DIN PN10 41 Wafer DIN PN16 42 Wafer DIN PN25 43 Flange JIS10K J1 Flange JIS20K J2 Flange JIS30K Standard paint Corrosion-proof paint XII X Bolt and None 2 nut SUS304 (only for wafer type) XIII J3 Flange JIS10K for 10 mm size flange *2 Flange JIS20K for 10 mm size flange *2 Flange ANSI 150 Options Basic model no. J4 J5 A1 Flange ANSI 300 A2 Flange DIN PN10 D1 Flange DIN PN16 D2 Flange DIN PN25 D3 IV Electrode V VI VII VIII IX X XI SUS316L L ASTM B574 (Hastelloy C-276 equivalent) C Titanium K Zirconium H Tantalum T Nickel N Platinum-iridium P Grounding SUS316 S ring ASTM B575 (Hastelloy C-276 equivalent) C Titanium K Zirconium H Tantalum T Platinum P Nickel N Wiring G1/2 internal thread A connection G1/2 internal thread with plastic water tight gland B G1/2 internal thread with brass Ni-plated watertight gland C 1/2NPT internal thread (must be selected for FM approval)*4 D CM20 internal thread E G1/2 internal thread with two plastic watertight glands J G1/2 internal thread with two brass Ni-plated watertight gland K Face-to-face Standard A dimension Replacement for SMT3000 (for wafer type 40 to 100 mm) S Installation / Horizontal piping / Right side viewed from upstream Display Horizontal piping / Left side viewed from upstream direction Horizontal piping / Downstream side Horizontal piping / Upstream side Vertical piping / Right side of piping / Flow direction: Upward Vertical piping mounting / Left side of piping / Flow direction: Upward Calibration Standard Output / com- Volume flow 4-20mA DC output/with SFC communication munication Volume flow DE output/with communication Volume flow 4-20mA DC output with HART communication Approval/ None Certification FM approval, Class I, II, III, Division 1, Groups A, B, C, D, E, F & G, T4 CSA certification, Class I, II, III, Division 1, Groups A, B, C, D, E, F & G, T4 FM approval, NI for Class I, II, III, Division 2, Groups A, B, C, D, F & G, T4 CSA certification, Class I, II, III, Division2, Groups A, B, C, D, E, F & G, T4 ATEX Type nA certification NPSI Type nA certification Ex nAII T4 to T6 -9- Display direction code "A" Display direction code "B" Display Direction of flow Direction of flow Display Display direction code "C" Display direction code "D" Display A B C D E F Display Direction of flow Direction of flow Display direction code "E" Display direction code "F" J E D T Direction of flow X *5 1 *5 2 4 6 Note) Direction of flow *1: Flange of size 2.5 to 15 mm detector is 15 mm flange. *2: Available for size 2.5 to 10 mm detector. *3: Must be selected if tagging is required. *4: Must select “Approval 1 or 2”. *5: Must select “Wiring connection D”. *6: This option is not applicable except if the approval/certification code is "X." No. SS2-MTG300-0100 Azbil Corporation MagneW Two-wire PLUS+ Wafer/Flange remote type converter Model MTG14C - I II III IV - Options (some options can be selected per each model) Basic model no. Selections Options MTG14C I Analog output / communication - Volume flow 4-20 mA DC output / with SFC communication E Volume flow DE output / with communication D Volume flow 4-20 mA DC output / with HART communication T II Wiring connection III Converter mounting IV Approval G1/2 internal thread A G1/2 internal thread with a plastic water-tight gland B G1/2 internal thread with a brass Ni-plated water-tight gland C 1/2NPT internal thread D CM20 internal thread E Wall mounting with standard bracket G 2-inch pipe mounting with standard bracket H None X FM approval, Class I, II, III, Division 2, Groups A, B, C, D, F & G, T4 CSA certification, Class I, II, III, Division 2, Groups A, B, C, D, E, F & G, T4 *2 2 - V Option None X Traceability certificate B With the Tag number plate on the converter housing *1 K Corrosion-proof paint 2 Note) *1: Must be selected if tagging is required. *2: Must select “Wiring connection D”. MagneW Two-wire PLUS+ Wafer/Flange remote type cable Model SMC11 - I II III Basic model no. Selections SMC11 I II Cable Terminals for detector III Terminals for converter 2m (6 feet 8 inches) 02 3m (10 feet) 03 4m (13 feet 4 inches) 04 5m (16 feet 8 inches) 05 10 m (33 feet 4 inches) 10 15 m (50 feet) 15 20 m (66 feet 8 inches) 20 30 m (100 feet) 30 40 m (133 feet 4 inches) 40 50 m (166 feet 8 inches) 50 60 m (200 feet) 60 70 m (233 feet 4 inches) 70 With terminals A With terminals A - 10 - Azbil Corporation No. SS2-MTG300-0100 MagneW Two-wire PLUS+ Wafer/Flange remote type detector Model MTG18B - I II III IV V VI VII VIII IX - Options (some options can be selected per each model) Basic model no. Selections Options MTG18B II Lining 10 mm (3/8 inch) 010 X None 15 mm (1/2 inch) 015 B Traceability certificate 25 mm (1 inch) 025 40 mm (1½ inches) 040 C Material certificate (electrode/ grounding ring) 50 mm (2 inches) 050 G Gasket for plastic piping 65 mm (2½ inches) 065 80 mm (3 inches) 080 K With the Tag number plate on the terminal box *1 100 mm (4 inches) 100 2 Corrosion-proof paint 150 mm (6 inches) 150 200 mm (8 inches) 200 4 Attached stainless steel 304 bolts and nuts for installation *2 PFA III Pipe Wafer JIS10K connection Wafer JIS16/20K IV Electrode P 11 12 Wafer JIS30K 13 Wafer ANSI 150 21 Wafer ANSI 300 22 Wafer DIN PN10 41 Wafer DIN PN16 42 Wafer DIN PN25 43 Flange JIS10K J1 Flange JIS20K J2 Flange JIS30K J3 Flange JIS10K for 10 mm size flange J4 Flange JIS20K for 10 mm size flange J5 Flange ANSI 150 A1 Flange ANSI 300 A2 Flange DIN PN10 D1 Flange DIN PN16 D2 Flange DIN PN25 D3 Note) *1: Must be selected if tagging is required. *2: Available for wafer type. *3: Must select “Wiring connection D”. SUS316L L ASTM B574 (Hastelloy C-276 equivalent) C Titanium K Zirconium H Tantalum T Nickel N Platinum-iridium P V Grounding SUS316 ring ASTM B575 (Hastelloy C-276 equivalent) S C Titanium K Zirconium H Tantalum T Platinum P VI Wiring G1/2 internal thread connection G1/2 internal thread with plastic water-tight gland A B G1/2 internal thread with brass Ni-plated water-tight gland C 1/2NPT internal thread D CM20 internal thread E VII Face-to-face Standard dimension Azbil Corporation's SMT3000 wafer type A S VIII Calibration Standard calibration J IX Approval/ None Certification FM approval, NI for Class I, II, III, Division 2, Groups A, B, C, D, F & G, T4 *3 CSA certification, Class I, II, III, Division 2, Groups A, B, C, D, E, F & G, T4 - 11 - X 2 Options I Diameter - No. SS2-MTG300-0100 Azbil Corporation DIMENSIONS All dimensions are in millimeters, dimensions in brackets () are in inches (inch). Model MTG18A - Flange type size 2.5 mm (0.1 inch) to 15 mm (1/2 inch) - Flange type size 25 mm (1 inch) (5.33) (5.35) Flange type (3.37) Name plate (1.97) Size 2.5 mm to 15 mm (0.1 inch to 1/2 inch) (2.76) (0.98) ( (10.63) 4.41) (5) (1.85) M4 Grounding terminal Grounding ring (2.83) (2.80) Case (0.08) Flange Electrode L Refer to Note 1 ( ) ( 0.35 ( 2)) (3.54) (4.33) Terminal (5.33) (5.35) Name plate Symbol (3.37) (1.97) (1.85) Grounding Pulse output or contact output (selectable) (2.76) (0.98) ( 4.41) (5) (3.03) Case Description Flow rate signal M4 Grounding terminal Grounding ring Flange type Size 25 mm (1 inch ) Flange (7.87) Electrode Refer to Note 1 Note 1 • When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension. • When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to the face-to-face dimension. Table 1 Size mm (inch) 2.5 to 10 (0.1 to3/8) 15 (1/2) 25 (1) Model no. Flange rating Dimension L Weight (kg) Dimension L Weight (kg) H Dimension H1 Weight (kg) J1 J2 J3 10K 20K 30K 160 6.8 200 7 267 63 9.2 160 7 200 7.2 267 63 9.5 160 8 200 8.2 269 65 10.3 J4 J5 A1 A2 D1/D2 D3/D4 DIN 10K 20K 150 300 PN 10/16 PN 25/40 160 6.7 200 6.9 - 160 6.8 200 7 - 160 (6.3) 6.4 (14.1 lb) 200 (7.87) 6.6 (14.6 lb) 258 (10.16) 54 (2.13) 8.4 (18.5 lb) 160 (6.3) 6.9 (15.2 lb) 200 (7.87) 7.1 (15.7 lb) 266 (10.47) 62 (2.44) 9.5 (20.9 lb) JIS ANSI 10 mm flange 10 mm flange - 12 - 160 6.9 200 7.1 262 58 9.1 160 7.1 200 7.3 262 58 9.4 Azbil Corporation No. SS2-MTG300-0100 Model MTG18A - Flange type size 40 mm (1½ inch) to 100 mm (4 inches) (5.33) (5.35) Name plate (3.37) (1.97) (2.76) ( 4.41) (5) (0.98) (1.85) M4 Grounding terminal H2 Case Grounding ring Flange L Electrode Refer to Note 1 Symbol Description Flow rate signal Flange type Grounding Pulse output or contact output (selectable) Terminal Size 40 mm to 100 mm (11/2 inch to 4 inches) Note 1 • When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension. • When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to the face-to-face dimension. Table 2 Size mm (inches) 40 (1.5) Model no. Flange rating Dimension Weight 50 (2) Dimension Weight 65 (2.5) Dimension Weight 80 (3) Dimension Weight 100 (4) J1 Dimension Weight L H H1 H2 (kg) L H H1 H2 (kg) L H H1 H2 (kg) L H H1 H2 (kg) L H H1 H2 (kg) 10K 200 296 85 84 8.3 200 310 90 93 11.9 200 329 102 100 13.9 200 345 110 108 14.4 250 367.5 120 120.5 20.2 J2 JIS 20K 200 296 85 84 8.6 200 310 90 93 12 200 329 102 100 14 200 354 119 108 16.7 250 376.5 129 120.5 23.7 J3 A1 A2 D1/D2 ANSI 30K 200 307 96 84 11 200 316 96 93 13.7 200 343 116 100 15.7 200 359 124 108 20.4 250 384.5 137 120.5 28.6 150 200 (7.87) 288 (11.34) 77 (3.03) 84 (3.31) 7.8 (17.2 lb) 200 (7.87) 308 (12.13) 88 (3.46) 93 (3.66) 12.3 (27.1 lb) 200 (7.87) 330 (12.99) 103 (4.06) 100 (3.94) 14.3 (31.5 lb) 200 (7.87) 346 (13.62) 113 (4.45) 108 (4.25) 17.3 (38.1 lb) 250 (9.84) 378.5 (14.90) 131 (5.16) 120.5 (4.74) 25.1 (55.3 lb) - 13 - D3/D4 DIN 300 200 (7.87) 305 (12.01) 94 (3.7) 84 (3.31) 10.1 (22.3 lb) 200 (7.87) 316 (12.44) 96 (3.78) 93 (3.66) 13.8 (30.4 lb) 200 (7.87) 388 (13.31) 111 (4.37) 100 (3.94) 15.8 (34.8 lb) 200 (7.87) 359 (14.13) 124 (4.88) 108 (4.25) 21.3 (47.0 lb) 250(9.84) 392.5 (15.45) 145 (5.71) 120.5 (4.74) 34.2 (75.4 lb) PN 10/16 200 302 91 84 8.7 200 316 96 93 13.3 200 334 107 100 15.3 200 354 119 108 14.4 250 373.5 126 120.5 19.6 PN 25/40 200 302 91 84 9.7 200 316 96 93 13.8 200 334 107 100 15.8 200 354 119 108 16.5 250 381.5 134 120.5 23.4 No. SS2-MTG300-0100 Azbil Corporation Model MTG18A - Flange type size 150 mm (6 inches) and 200 mm (8 inches) (5.33) (5.35) (1.97) (3.37) (2.76) (0.98) ( 4.41) (5) (1.85) Case H2 M4 Grounding terminal Grounding ring Flange Electrode L Refer to Note 1 Symbol Description Flow rate signal Flange type Grounding Pulse output or contact output (selectable) Size 150 mm and 200 mm (6 inches and 8 inches) Terminal Note 1 • When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension. • When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to the face-to-face dimension. Table 3 Size mm (inches) Model no. Flange rating Dimension 150 (6) 200 (8) L H H1 H2 Weight (kg) Dimension L H H1 H2 Weight (kg) J1 10K 300 462 175 160 34.4 350 508 196 185 49.8 J2 JIS 20K 300 476 189 160 41.7 350 515 203 185 59.8 J3 A1 A2 D1/D2 ANSI 30K 150 300 PN 10/16 300 300 (11.81) 300 (11.81) 300 487 461 (18.15) 483 (19.02) 465 200 174 (6.85) 196 (7.72) 178 160 160 (6.3) 160 (6.3) 160 54.3 37.2 (82.0 lb) 56.2 (123.9 lb) 30.7 350 350 (13.78) 350 (13.78) 350 531 516 (20.31) 537 (21.14) 514 219 204 (8.03) 225 (8.86) 202 185 185 (7.28) 185 (7.28) 185 87 61.8 (136.2 lb) 90.8 (200.2 lb) 48.1 - 14 - D3 DIN PN 25 300 473 186 160 38.6 350 526 214 185 68.5 D4 PN40 300 473 186 160 38.6 350 534 222 185 72 Azbil Corporation No. SS2-MTG300-0100 Model MTG18A - Wafer type size 25 mm (1 inch) to 100 mm (4 inches) (5.33) Name plate (5.35) (3.37) (1.97) H (2.76) (0.98) ( 4.41) (5) (1.85) Case M4 grounding terminal (H1) H2 D Grounding ring L Electrode Refer to note1 Symbol Description Flow rate signal Wafer type Grounding Pulse output or contact output (selectable) Terminal Size 25 mm and 100 mm (1 inch and 4 inches) Note 1 • When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension. • When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to the face-to-face dimension. Table 4 Flange rating Face-to-face dimension code L Dimension size Weight 25 mm (1 inch) A 40 mm (1½ inch) A S 50 mm (2 inches) A S 65 mm (2½ inches) A 80 mm (3 inches) A S 100 mm (4 inches) A S 94 (3.7) 80 (3.15) 98 (3.86) 86 (3.39) 104 (4.09) 96 (3.78) 106 (4.17) 130 (5.12) 120 (4.72) 150 (5.91) H 238 (9.37) 254.5 (10.02) 272 (10.71) 289 (11.38) 302 (11.89) 327 (12.87) H1 34 (1.34) 43.5 (1.71) 52 (2.05) 62 (2.44) 67 (2.64) 79.5 (3.13) H2 77 (3.03) 84 (3.31) 93 (3.66) 100 (3.94) 108 (4.25) 120.5 (4.74) D 68 (2.68) 87 (3.43) 104 (4.09) 124 (4.88) 134 (5.28) 159 (6.26) (kg) 3.7 (8.2 lb) 3.8 4.3 4.4 5.0 (8.4 lb) (9.5 lb) (9.7 lb) (11.0 lb) - 15 - 5.5 (12.1 lb) 6.4 7.1 8.2 9.2 (14.1 lb) (15.7 lb) (18.1 lb) (20.3 lb) No. SS2-MTG300-0100 Azbil Corporation Model MTG14C - Converter (4.41) (0.13) (10.12) (R0.31) (3.63) Plate (10.67 +0.040 ) (R0.49) (R0.49) (2.91+0.02) (0.63) (R0.49) (0.77) (0.75) (R0.16) (1.77) (1.19 max.) Wall mounting dimension (1.77) (9.92) (2.74) (4.36) Wall mounting (4.41) (3.63) Grounding Pulse output or contact (selectable) Excitation output Flow rate signal input (1.77) (1.77) (4.92) * Terminal screw: M4 (6.30) PULSE/ STATUS OUT X Y A B C Flow rate signal (1.19 max.) I-OUT Description (0.63) Symbol (10.12) Terminal (2.74) (4.36) 2-inch pipe mounting (1.23) Model SMC11 - Cable Wiring diagram Detector A C B X Y L Cable Converter A C B X Y Note) Grounding resistance: 100W max. L: Cable length - 16 - Azbil Corporation No. SS2-MTG300-0100 Model MTG18B - Detector - Flange type size 10 mm (3/8 inch) and 15 mm (1/2 inch) - Flange type size 25 mm (1 inch) Blind plug (1.19 max.) (3.31) (1.85) (0.98) (3.31) Waterproof gland (optional) Size 10 mm and 15 mm (3/8 and 1/2 inch) Tag plate (2.80) Nameplate Grounding ring (0.08) (2.83) (7.48) Flange type Terminal box (3.54) (4.43) (2.05) Electrode 9 ( 2) ( 0.35 ( 2)) Refer to note 1 (4.43) Terminal Blind plug (1.19 max.) (3.31) (1.85) (0.98) Symbol (3.31) Terminal box Waterproof gland (optional) Tag plate Nameplate (3.03) Description X Y A B C Grounding ring Excitation input Flow rate signal output H Grounding H1 * Terminal screw: M4 Flange type (7.89) Electrode Refer to note 1 Size 25 mm (1 inch) Note 1 • When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension. • When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to the face-to-face dimension. Table 5 Model no. Size mm (inches) J1 J2 J3 J4 J5 A1 JIS Flange rating 10 (3/8) Dimension 15 (1/2) Dimension 25 (1) Dimension Weight Weight Weight 10K 20K 30K A2 D1/D2 ANSI DIN 10K 20K 150 300 160 (6.3) 160 (6.3) 10 mm flange 10 mm flange L 160 160 160 160 160 (kg) 5 5.2 6.2 4.9 5 L 200 200 200 200 200 (kg) 5.2 5.4 6.4 5.1 5.2 4.6 (10.1 lb) 5.1 (11.2 lb) 200 (7.87) D3/D4 200 (7.87) 4.8 (10.6 lb) 5.3 (11.7 lb) PN 10/16 PN 25/40 160 160 5.1 5.3 200 200 5.3 5.5 H 187 187 189 - - 188 (7.4) 186 (7.32) 182 182 H1 63 63 65 - - 54 (2.13) 62 (2.44) 58 58 (kg) 7.4 7.7 8.5 - - 7.3 7.6 - 17 - 6.6 (14.6 lb) 7.7 (17.0 lb) No. SS2-MTG300-0100 Azbil Corporation Model MTG18B - Detector - Flange type size 40 mm (1½ inch) to 100 mm (4 inches) (1.19 max.) (3.31) Blind plug (3.31) Waterproof gland (optional) Tag plate (1.85) (0.98) Terminal box Nameplate H2 Case Grounding ring Flange L Electrode Refer to Note 1 Symbol X Y A B C Description Excitation input Flow rate signal output Flange type Grounding Size 40 mm to 100 mm (11/2 inch to 4 inches) * Terminal screw: M4 Terminal Note 1 • When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension. • When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to the face-to-face dimension. Table 6 Size mm (inches) 40 (1.5) Model no. Flange rating Dimension Weight 50 (2) Dimension Weight 65 (2.5) Dimension Weight 80 (3) Dimension Weight 100 (4) J1 Dimension Weight L H H1 H2 (kg) L H H1 H2 (kg) L H H1 H2 (kg) L H H1 H2 (kg) L H H1 H2 (kg) 10K 200 216 85 84 6.5 200 230 90 93 10.1 200 249 102 100 12.1 200 265 110 108 16.6 250 287.5 120 120.5 18.4 J2 JIS 20K 200 216 85 84 6.8 200 230 90 93 10.2 200 249 102 100 12.2 200 274 119 108 14.9 250 296.5 129 120.5 21.9 J3 A1 A2 D1/D2 ANSI 30K 200 227 96 84 9.2 200 236 96 93 11.9 200 263 116 100 13.9 200 279 124 108 18.6 250 304.5 137 120.5 26.8 - 18 - 150 200 (7.87) 208 (8.19) 77 (3.03) 84 (3.31) 6 (13.2 lb) 200 (7.87) 228 (8.98) 88 (3.46) 93 (3.66) 10.5 (23.1 lb) 200 (7.87) 250 (9.84) 103 (4.06) 100 (3.94) 12.5 (27.6 lb) 200 (7.87) 266 (10.47) 113 (4.45) 108 (4.25) 15.5 (34.2 lb) 250 (9.84) 298.5 (11.75) 131 (5.16) 120.5 (4.74) 23.3 (51.4 lb) D3/D4 DIN 300 200 (7.87) 225 (8.86) 94 (3.7) 84 (3.31) 8.3 (18.3 lb) 200 (7.87) 236 (9.29) 96 (3.78) 93 (3.66) 12 (26.5 lb) 200 (7.87) 258 (10.16) 111 (4.37) 100 (3.94) 14 (30.9 lb) 200 (7.87) 279 (10.98) 124 (4.88) 108 (4.25) 19.5 (43.0 lb) 250 (9.84) 312.5 (12.30) 145 (5.71) 120.5 (4.74) 32.4 (71.4 lb) PN 10/16 200 222 91 84 6.9 200 236 96 93 11.5 200 254 107 100 13.5 200 274 119 108 12.6 250 293.5 126 120.5 17.8 PN 25/40 200 222 91 84 7.9 200 236 96 93 12 200 254 107 100 14 200 274 119 108 14.7 250 301.5 134 120.5 21.6 Azbil Corporation No. SS2-MTG300-0100 Model MTG18B - Detector - Flange type size 150 mm (6 inches) and 200 mm (8 inches) (3.31) Blind plug (3.31) Terminal box Tag plate (1.85) (0.98) (1.19 max.) Waterproof gland (optional) Nameplate H2 Case Grounding ring Flange Electrode L Refer to Note 1 Symbol X Y A B C Description Excitation input Flow rate signal output Flange type Size 150 mm and 200 mm (6 inches and 8 inches) Grounding * Terminal screw: M4 Terminal Note 1 • When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension. • When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to the face-to-face dimension. Table 7 Size mm (inches) 150 (6) Model no. Flange rating Dimension Weight 200 (8) J1 Dimension Weight J2 J3 A1 JIS A2 D1/D2 ANSI D3 D4 DIN 10K 20K 30K 150 300 L 300 300 300 300 (11.81) 300 (11.81) 300 300 300 H 382 396 407 381 (15) 403 (15.87) 385 393 393 H1 175 189 200 174 (6.85) 196 (7.72) 178 186 186 H2 160 160 160 160 (6.3) 160 (6.3) 160 160 160 (kg) 32.6 39.9 52.5 35.4 (78 lb) 54.4 (119.9 lb) 28.9 36.8 36.8 L 350 350 350 350 (13.78) 350 (13.78) 350 350 350 H 428 435 451 436 (17.17) 457 (17.99) 434 446 454 H1 196 203 219 204 (8.03) 225 (8.86) 202 214 222 H2 185 185 185 185 (7.28) 185(7.28) 185 185 185 (kg) 48 58 85.2 60 (132.3 lb) 89 (196.2 lb) 46.3 66.7 70.2 - 19 - PN 10/16 PN 25 PN 40 No. SS2-MTG300-0100 Azbil Corporation Model MTG18B - Detector - Wafer type size 25 mm (1 inch) to 100 mm (4 inches) (1.19 max.) (3.31) (0.98) Terminal box Waterproof gland (optional) Tag plate (1.85) Blind plug (3.31) Nameplate Grounding ring D Electrode Refer to Note 1 Description Symbol X Y A B C Excitation input Flow rate signal output Wafer type Grounding Size 25 mm to 100 mm (1 inch to 4 inches) * Terminal screw: M4 Terminal Note 1 • When grounding ring material is SUS316, gasket dimension is not included to the face-to-face dimension. • When grounding ring material is other than SUS316, a 3 mm of Teflon gasket dimension is included to the face-to-face dimension. Table 8 Flange rating Face-to-face dimension code L H DimenH1 sion size H2 D Weight 25 mm (1 inch) A 40 mm (1½ inch) A S 50 mm (2 inches) A S 94 (3.7) 80 (3.15) 98 (3.86) 86 (3.39) 104 (4.09) 158 (6.22) 174.5 (6.87) 192 (7.56) 34 (1.34) 43.5 (1.71) 52 (2.05) 77 (3.03) 84 (3.31) 93 (3.66) 68 (2.68) 87 (3.43) 104 (4.09) 2 2 2.5 2.6 3.2 (kg) (4.4 lb) (4.4 lb) (5.5 lb) (5.7 lb) (7.1 lb) 65 mm (2½ inches) A 80 mm (3 inches) A S 100 mm (4 inches) A S 96 (3.78) 106 (4.17) 130 (5.12) 120 (4.72) 150 (5.91) 209 (8.23) 222 (8.74) 247 (9.72) 62 (2.44) 67 (2.64) 79.5 (3.13) 100 (3.94) 108 (4.25) 120.5 (4.74) 124 (4.88) 134 (5.28) 159 (6.26) 3.7 4.6 5.3 6.4 7.4 (8.2 lb) (10.1 lb) (11.7 lb) (14.1 lb) (16.3 lb) Please read the "Terms and Conditions" from the following URL before ordering or use: http://www.azbil.com/products/bi/order.html Specifications are subject to change without notice. 1-12-2 Kawana, Fujisawa Kanagawa 251-8522 Japan URL: http://www.azbil.com/ - 20 (10) 1st Edition: Issued in May 2010 2nd Edition: Issued in June 2012 No part of this publication may be reproduced or duplicated without the prior written permission of Azbil Corporation.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement