FAP Certificate of Conformance (Bureau Veritas)

FAP Certificate of Conformance (Bureau Veritas)
AVS.4.13.14020/CC-08
Issuing Center: ANTWERP
Page 1/2
VERITAS
CERTIFICATE OF CONFORMITY
To ICAO Annex 14 - Fifth Edition - July 2009
(Standards and recommended practices)
To FAA Advisory Circular 150/5345-46
To Technical Specification IEC 61827
AENA specification PPT 018-01/08
Product:
FAP-1-xxx
Clear & Red
Manufactu red by ADS in Belgium
Application : Approach Centerline, Barrette & Side Row Lights
- was found in conformity with :
• the catalogue sheet A.02.3 12
• the ICAO - Annex 14 - Volume I - §5.3.4: VFR & CAT I, II , III for light output
• the FAA AC 150/5345-46 mechanical requirements for L-850 Inset Lights
• The IEC TS 61827
• The AENA Specification PPT 018-01/08
- Date of inspection: May 29 th , 2013 .
- and has been, upon request of:
ADB
Leuvensesteenweg, 585
B -1930 ZAVENTEM - BELGIUM
- inspected in conform ity with the applicable requirements of
• the catalogue sheets A. 02.312
• the ICAO -Annex 14 - Volume I - §5.3.4: VFR & CAT I, II , III for light output
• the FAA AC 150/5345-46 mechanical requirements for L-850
• The AENA Specification PPT 018-01/08 & the IEC TS 61827
Issued at Antwerp, May 29th, 2013
Mr Rudi Vandenbempt
Inspector Industry
BUREAU VERITAS ANTWERP
~\I VEItI~
l":,:,.="'1I'
~l ~
Particulars of inspection: detailed hereafter
Th is certificate is on ly va lid for a period of 5 years from the issua nce date, as far as no chan ges
of production process, equipment characteristi cs nor of app licable req uirem ent s occur during
this period of validity.
AVS.4.13.14020/CC-08
Issuing Center: ANTWERP
Page 2 / 2
VERITAS
The following survey operations have been carried out without noticeable
remarks:
•
Attendance to tests at the Laboratory premises of the manufacturer:
o Examination of test equipment
o Checking of installation of units before testing
o Attendance to photometric tests per applicable procedures and method
o Attendance to the Colorimetric tests per applicable procedure & method
o Attendance to the Static Load test
o Attendance to the Surface Temperature test
o Attendance to the gas tightness tests
•
•
Statistical test results per IEC 61827
Test results are detailed in the attached test records.
CONCLUSION
Taking into account the satisfactory results of actual tests and examinations we confirm
that the manufacturing and the test results for the above specified units are in
conformity with applicable standards, specifications and data sheets.
(Details of standards and specifications are indicated on page 1 of this certificate and
data sheet as per catalogue).
ENCLOSURE
Test records of testings which have been attended, duly stamped for identification by
BUREAU VERITAS:
Photometric test reports:
• Results of intensity values inside the beam
• Isocandela curves
• Colorimetry
• Static Load test
• Surface temperature test
• Gas tightness test
Issued at Antwerp, May 29th, 2013
Mr Rudi Vandenbempt
Inspector Industry
BUREAU VERITAS ANTWERP
~
This certificate is only valid for a period of 5 years from the issuance date, as far as no changes
of production process, equipment characteristics nor of app licab le requirements occu r during
this period of validity.