datasheet for HLG-240H

Add to my manuals
6 Pages

advertisement

datasheet for HLG-240H | Manualzz

240W Single Output Switching Power Supply

F 110

H L G - 2 4 0 H s e r i e s

¡½

¡E

¡E

Features :

Universal AC input / Full range (up to 305VAC)

Built-in active PFC function

¡E

¡E

Protections: Short circuit / Over current / Over voltage / Over temperature

Cooling by free air convection

¡E

¡E

OCP point adjustable through output cable or internal potentiometer

¡E

IP67 / IP65 design for indoor or outdoor installations

Three in one dimming function (1~10Vdc or PWM signal or resistance)

¡E

Suitable for LED lighting and street lighting applications

¡E

Compliance to worldwide safety regulations for lighting

¡E

¡E

Suitable for dry / damp / wet locations

5 years warranty (Note.10)

SELV

IP65 IP67

..

HLG-240H-12 A Blank : IP67 rated. Cable for I/O connection.

A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.

B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.

C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal potentiometer.

D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.

SPECIFICATION

MODEL

OUTPUT

INPUT

HLG-240H-12 HLG-240H-15 HLG-240H-20 HLG-240H-24 HLG-240H-30 HLG-240H-36 HLG-240H-42

DC VOLTAGE

CONSTANT CURRENT REGION

Note.4

RATED CURRENT

RATED POWER

12V

6 ~12V

16A

192W

RIPPLE & NOISE (max.) Note.2

150mVp-p

VOLTAGE ADJ. RANGE Note.6

11.2 ~ 12.8V

15V

7.5 ~ 15V

15A

225W

150mVp-p

14 ~ 16V

20V

10 ~ 20V

12A

240W

150mVp-p

18.6 ~ 21.4V

24V

12 ~ 24V

10A

240W

150mVp-p

22.4 ~ 25.6V

VOLTAGE TOLERANCE Note.3

Can be adjusted by internal potentiometer A type only

CURRENT ADJ. RANGE

LINE REGULATION

LOAD REGULATION Note.8

SETUP, RISE TIME Note.9

8 ~ 16A

¡Ó2.5%

¡Ó0.5%

¡Ó2.0%

7.5 ~ 15A

¡Ó2.0%

¡Ó0.5%

¡Ó1.5%

6 ~ 12A

¡Ó1.0%

¡Ó0.5%

¡Ó1.0%

2500ms, 80ms at full load 230VAC /115VAC

5 ~ 10A

¡Ó1.0%

¡Ó0.5%

¡Ó0.5%

HOLD UP TIME (Typ.) 15ms at full load 230VAC /115VAC

30V

15 ~ 30V

8A

240W

200mVp-p

28 ~ 32V

4 ~ 8A

¡Ó1.0%

¡Ó0.5%

¡Ó0.5%

36V

18 ~ 36V

6.7A

241.2W

250mVp-p

33.5 ~ 38.5V

3.3 ~ 6.7A

¡Ó1.0%

¡Ó0.5%

¡Ó0.5%

42V

21 ~ 42V

5.72A

240.24W

250mVp-p

39 ~ 45V

2.86 ~ 5.72A

¡Ó1.0%

¡Ó0.5%

¡Ó0.5%

VOLTAGE RANGE

FREQUENCY RANGE

POWER FACTOR (Typ.)

EFFICIENCY (Typ.)

Note.5

AC CURRENT (Typ.)

INRUSH CURRENT (

LEAKAGE CURRENT

Typ .)

90 ~ 305VAC

47 ~ 63Hz

127 ~ 431VDC

PF>0.98/115VAC, PF>0.95/230VAC at full load (Please refer to "Power Factor Characteristic" curve)

90% 90% 92% 93% 93% 93% 93%

4A / 115VAC 2A / 230VAC

COLD START 75A/230VAC

1.2A / 277VAC

<0.75mA / 277VAC

HLG-240H-48

48V

24 ~ 48V

5A

240W

250mVp-p

44.8 ~ 51.2V

2.5 ~ 5A

¡Ó1.0%

¡Ó0.5%

¡Ó0.5%

93.5%

HLG-240H-54

54V

27 ~ 54V

4.45A

240.3W

350mVp-p

50 ~ 57V

2.23 ~ 4.45A

¡Ó1.0%

¡Ó0.5%

¡Ó0.5%

94%

PROTECTION

ENVIRONMENT

SAFETY &

EMC

OTHERS

NOTE

OVER CURRENT

SHORT CIRCUIT

OVER VOLTAGE

OVER TEMPERATURE

WORKING TEMP.

WORKING HUMIDITY

STORAGE TEMP., HUMIDITY

TEMP. COEFFICIENT

VIBRATION

Note.4

95 ~ 108%

Protection type : Constant current limiting, recovers automatically after fault condition is removed

Hiccup mode, recovers automatically after fault condition is removed

13.5 ~ 18V 17.5 ~ 21.5V 23.5 ~ 27.5V 27 ~ 34V 33 ~ 39V 43 ~ 49V 48 ~ 54V

Protection type : Shut down and latch off o/p voltage, re-power on to recover

105 5 (TSW1) 95 5 (TSW1)

Protection type : Shut down o/p voltage, recovers automatically after temperature goes down

-40 ~ +70

¢J

(Refer to "Derating Curve")

20 ~ 95% RH non-condensing

-40 ~ +80 ¢J , 10 ~ 95% RH

¡Ó 0.03%/ ¢J (0 ~ 50 ¢J )

10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes

55 ~ 63V 60 ~ 67V

SAFETY STANDARDS Note.7

UL1012, CAN/CSA-C22.2 No. 107.1-01, UL8750, CSA C22.2 No. 250.0-08, TUV EN61347-1, EN61347-2-13 independent

(except for HLG-240H C type), UL60950-1, UL8750, TUV EN60950-1, IP65 or IP67, J61347-1, J61347-2-13 approved

WITHSTAND VOLTAGE

ISOLATION RESISTANCE

EMC EMISSION

I/P-O/P:3.75KVAC

I/P-FG:1.88KVAC

O/P-FG:0.5KVAC

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 ¢J / 70% RH

Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (

¡Ù

50% load) ; EN61000-3-3

EMC IMMUNITY

MTBF

Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A

207.9K hrs min.

MIL-HDBK-217F (25 ¢J )

244.2*68*38.8mm (L*W*H)(HLG-240H-Blank/A/B) 251*68*38.8mm (L*W*H)(HLG-240H-C) DIMENSION

PACKING 1.3Kg; 12pcs/16.6Kg/0.84CUFT(HLG-240-Blank/A/B) 1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240-C)

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25

¢J of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.

5. Derating may be needed under low input voltages. Please check the static characteristics for more details.

6. Type A and type C only.

7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.

8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.

9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

10. Refer to warranty statement.

240W Single Output Switching Power Supply

Mechanical Specification

Blank:(HLG-240H)

244.2

220.2

12

9.6

FG (Green/Yellow)

AC/L(Brown)

AC/N(Blue)

T case

110.1

¡° T case: Max. Case Temperature.

H L G - 2 4 0 H s e r i e s

Case No.994C

Unit:mm

-V(Black)

+V(Red)

¡°IP67 rated. Cable for I/O connection.

A Type:(HLG-240H-_A)

12

9.6

FG (Green/Yellow)

AC/L(Brown)

AC/N(Blue)

244.2

220.2

T case

¡° T case: Max. Case Temperature.

110.1

Vo

ADJ.

Io

ADJ.

¡° IP65 rated. Output voltage and constant current level can be adjusted through internal

(Can access by removing the rubber stopper on the case.) potentiometer.

B Type:(HLG-240H-_B)

12

9.6

244.2

220.2

FG (Green/Yellow)

AC/L(Brown)

AC/N(Blue)

T case

110.1

¡° T case: Max. Case Temperature.

-V(Black)

+V(Red)

-V(Black)

+V(Red)

DIM+(Blue)

DIM-(White)

File Name:HLG-240H-SPEC 2012-09-11

240W Single Output Switching Power Supply

C Type:(HLG-240-_C)

15.4

8

251

220.2

I/P

1

2

3

T case

110.1

Vo

ADJ.

H L G - 2 4 0 H s e r i e s

Io

ADJ.

1

2

O/P

¡° T case: Max. Case Temperature.

¡° Output voltage and constant current level can be adjusted through internal

(Can access by removing the rubber stopper on the case.) potentiometer.

AC Input Terminal Pin No. Assignment

Pin No.

1

2

3

Assignment

FG

AC/L

AC/N

DC Output Terminal Pin No. Assignment

Pin No.

1

2

Assignment

-V

+V

D Type(option):(HLG-240H-_D)

12

9.6

244.2

220.2

FG (Green/Yellow)

AC/L(Brown)

AC/N(Blue)

T case

110.1

¡° T case: Max. Case Temperature.

-V(Black)

+V(Red)

¡° IP67 rated. Timer dimming function, contact MEAN WELL for details.

Block Diagram

I/P

EMI FILTER

&

RECTIFIERS

PFC

CIRCUIT

POWER

SWITCHING

FG

O.L.P.

PFC

CONTROL

PWM & PFC

CONTROL

RECTIFIERS

&

FILTER

O.L.P.

DETECTION

CIRCUIT

O.V.P.

Fosc : 100KHz

+V

-V

DIM+

DIM-

(B Type)

File Name:HLG-240H-SPEC 2012-09-11

240W Single Output Switching Power Supply

H L G - 2 4 0 H s e r i e s

Derating Curve Static Characteristics

100VAC

230VAC

60

40

20

100

80

-40 -25 -10 0 15 30 50

AMBIENT TEMPERATURE ( ¢J )

60 70 (HORIZONTAL)

60

50

40

100

90

80

70

90 100 125 135 145 155 165 175 180 200 230 305

INPUT VOLTAGE (V) 60Hz

Power Factor Characteristic

Constant Current Mode

1 .0 0

0 .9 8

0 .9 6

0 .9 4

0 .9 2

0 .9 0

0 .8 8

0 .8 6

0 .8 4

0 .8 2

0 .8 0

0 .7 8

5 0 % 6 0 % 7 0 %

LOAD

8 0 % 9 0 % 1 0 0 %

(240W)

2 7 7 V a c

2 3 0 V a c

1 1 5 V a c

HLG-240H series possess superior working efficiency that up to 93.5% can be reached in field applications.

96

92

88

84

277Vac

230Vac

115Vac 80

76

72

10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

LOAD

File Name:HLG-240H-SPEC 2012-09-11

240W Single Output Switching Power Supply

H L G - 2 4 0 H s e r i e s

DRIVING METHODS OF LED MODULE

There are two major kinds of LED drive method "direct drive" and "with LED driver".

A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs.

Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).

100

(B)

Constant

Current area

(A) Constant

Voltage area

50

(max.)

(C)

Hiccup

Protection

50 95

Typical LED power supply I-V curve

DIMMING OPERATION (for B-type only)

Io (%)

FG (Green/Yellow)

AC/L(Brown)

AC/N(Blue)

HLG-240H

-V(Black)

+V(Red)

DIM+(Blue)

DIM-(White)

¡° Built-in 3 in 1 dimming function, IP67 rated. Output constant current level can be adjusted through output cable by connecting a resistance or

1 ~ 10Vdc or 10V PWM signal between DIM+ and DIM-.

¡° Please DO NOT connect "DIM-" to "-V".

¡° Reference resistance value for output current adjustment (Typical)

40K

£[

50K

£[

Resistance value

Single driver

Multiple drivers

(N=driver quantity for synchronized dimming operation)

10K

£[

20K

£[

30K

£[

10K /N £[ 30K /N

Percentage of rated current 10% 20% 30% 40% 50%

60K

£[

60%

70K

£[

70%

80K

£[

80%

90K

£[ 100K£[

90% 100%

OPEN

-----

95%~108%

¡° 1 ~ 10V dimming function for output current adjustment (Typical)

Dimming value 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V OPEN

80% 90% 100% 95%~108% Percentage of rated current

Percentage of rated current

10%

10%

20%

20%

30%

30%

40%

40%

50%

50%

60% 70%

¡° 10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz

Duty value 10% 20% 30% 40% 50% 60% 70%

60% 70%

80%

80%

90%

90%

100%

100%

OPEN

95%~108%

¡°Using the built-in dimming function on B-type model can't turn the lighting fixture totally dark. Please refer to the connection method below to achieve 0% brightness of the lighting fixture connecting to the LED power supply unit.

¡°Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.

Dimming connection diagram for turning the lighting fixture ON/OFF :

N FG L

Relay Switch Adjuster

0~100K Ohms resistance

1~10V DC Voltage

10V PWM Signal

Green/

Yellow

Brown

Blue

AC/L

AC/N

HLG-240H

B Type

DIM+

DIM-

V(-)

V(+)

Blue

White

Black

Red LED Lighting Fixture

Using a switch and relay can turn ON/OFF the lighting fixture.

1.Output constant current level can be adjusted through output cable by connecting a resistance or 1~10Vdc or 10V PWM signal between DIM+ and DIM-.

2.The LED lighting fixture can be turned ON/OFF by the switch.

File Name:HLG-240H-SPEC 2012-09-11

240W Single Output Switching Power Supply

H L G - 2 4 0 H s e r i e s

WATERPROOF CONNECTION

¡· Waterproof connector

Waterproof connector can be assembled on the output cable of HLG-240H to operate in dry/wet/damp or outdoor environment.

AC source

HLG-240H

I/P O/P

Size Pin Configuration (Female)

M12

Order No.

Suitable Current

¡· Cable Joiner

66

26 20

4-PIN

5A/PIN

M12-04

10A max.

5-PIN

5A/PIN

M12-05

10A max.

Size

M15

Order No.

Suitable Current

Pin Configuration (Female)

2-PIN

12A/PIN

M15-02

12A max.

CJ04-1 suitable for 14AWG~16AWG

CJ04-2 suitable for 18AWG~22AWG

LED Lamp

Up to four wires can be connected through this cable joiner by soldering or clamping by tools.

LED Lamp

HLG-240H

O/P Wires

¡°CJ04 cable joiner can be purchased independently for user's own assembly.

MEAN WELL order No. : CJ04-1, CJ04-2.

¡· Junction Box(Option )

220.2

382.2

FG (Green/Yellow)

AC/L(Brown)

AC/N(Blue)

3- PF 1/2"

76 10

5

2-

£r

5

-V(Black)

+V(Red)

3- PF 1/2"

¡°Optional junction box available for A / Blank - type , please contact MEAW WELL for details.

86

File Name:HLG-240H-SPEC 2012-09-11

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement