The BradCommunications SST PROFIBUS
The BradCommunications™ SST™ PROFIBUS® scanner
connects your Allen-Bradley® SLC™ 5/03 or higher controller
to PROFIBUS DP.
04 May. 10
DW2006134
Features
• Enhanced design!
…
…
…
…
•
•
•
•
•
•
•
PROFIBUS DP Scanner
For the Allen-Bradley SLC 500 Controller
100% backward compatible
with previous generation
(SST-PFB-SLC)
Manages DP-V1 Services
including SLC ladder logic
samples
Doubling of M0 and M1 data
area up to 1000 words
Module can “Set Slave” address
PROFIBUS DP Master Configuration
Software
Supports all PROFIBUS baud rates
including 31.25 and 45.45 kbps
Simultaneous operation of
PROFIBUS DP Master and Slave
Flash memory for storage of
DP Master I/O configuration
Fast, easy set up into SLC
backplane, PROFIBUS I/O data is
automatically mapped into the
SLC’s processor’s I, O files and into
MO and MI files residing on PB3SLC
Overview
The BradCommunications SST PROFIBUS scanner connects your
Allen-Bradley SLC 5/03 or higher controller to PROFIBUS as a master or slave to
scan or emulate PROFIBUS DP I/O. With the new user-defined data space of 2064
Bytes Input and 2064 Bytes Output, the BradCommunications™ SST™ Profibus
module provides a cost efficient solution to connect the SLC CPU with large
PROFIBUS networks.
Supports exported configuration
files from the SST DP configuration
software and Siemens COM
PROFIBUS
Multiple SST-PB3-SLC modules can
be used in one SLC rack
Protocols
• PROFIBUS DP-V0 Master Class 1&2
• PROFIBUS DP-V1 Master Class 1&2
• PROFIBUS DP-V0 Slave
SST-PB3-SLC
Typical Applications
• Packaging machinery
• Conveyor & handling systems
• Food products machinery
A 9-pin serial port included on the scanner provides for firmware upgrades in the
field and the upload of I/O configurations.
The SLC’s processor logic scan and the PROFIBUS I/O scan are independent of
each other. The SLC processor reads the scanner input data during its input scan
and writes the output data during its output scan. The scanner reads input data from
the slaves and writes output data to the slaves independent of what the SLC is
doing. Slave status, diagnostic status information on all slaves, network diagnostic
counters and DP Master diagnostic counters are maintained by the scanner. The
scanner does not require the set up of a G-file in the SLC.
PROFIBUS® DP Scanner
Diagnostic & Software Tools
Configuration Software
• Browse your DP network for slave
devices you want to include in your
DP Master configuration using the
DPView component
Scanner Software
•
•
Maintains slave status, diagnostic
status information on all slaves,
network diagnostic counters, and
DP Master diagnostic counters
Protocol
LAN Controller
Slaves Supported
I/O per Slave
I/O Mapping
(for SLC™)
Maintains network and I/O module
status information including:
•
•
•
DP Master Slave status table
Data Rate
Network diagnostic counters
DP Master diagnostic counters
Diagnostic LEDs
•
Network Specifications
COMM and SYS LEDs provide
immediate notification of network
and system errors
•
•
•
•
•
PROFIBUS network interface cards
(USB, PCI, CompactPCI, PC/104,
ISA, VME64) with many user
interfaces (DLL, OPC, ActiveX…)
PROFIBUS gateways to Serial and
Ethernet networks
IP67 PROFIBUS I/O modules
(M8/M12 connectors)
Full metal PROFIBUS connector
Cable, cordsets, receptacles
•
•
•
•
Connector
•
PROFIBUS DP-V0 Master, class 1&2
PROFIBUS DP-V1 Master, class 1&2
PROFIBUS DP-V0 Slave (up to 122 words of input
data and 122 words of output data as slave)
Siemens ASPC2
Maximum of 125
Maximum of 244 bytes in/out
I and O files: 32 words input + 32 words output
M1 and M0 files: 1000 words input + 1000 words
output (128 words in / out if configuring with COM
PROFIBUS)
Slave data is mapped into I, O, M0, M1 files in the
SLC. Mapping depends on addresses assigned in
the configuration created
9600, 19200, 31.25k, 45.45k, 93.75k, 187.5k, 500k,
1.5M, 3M, 6M, 12M
Belden 3079A
BradConnectivity™ Brad Harrison® 85-0001
PVR2 conductor with shield, UL-listed
DB9 female connector
Hardware Specifications
Bus Interface
Processors
PROFIBUS modules for
Allen-Bradley® ControlLogix®
•
•
•
•
•
Cable
Other PROFIBUS Products
•
•
•
•
Memory
Diagnostics
Backplane
Current Consumption
Operating T°
Storage T°
Relative Humidity
Pollution degree
Allen-Bradley® SLC™ 5/03 or higher
Protocol processor: Freescale Coldfire MCF5272
Backplane processor: Altera Cyclone II
• 2 MB of local Coldfire SDRAM
• 32 MB of local NIOS DDR
• 512 KB of onboard shared memory
• 512 KB of sectored flash memory
for storage of program and configuration data
Two LEDs indicate:
1. health of the PROFIBUS network (COMM)
2. communication status with PROFIBUS slaves (SYS)
750mA @ 5V from a supply delivering Separated Extra
Low Voltage (SELV)
0ºC (32ºF) up to +50ºC (122ºF)
-40ºC (-40°F) up to +85ºC (185°F)
5% to 95% non-condensing
Degree 1 - no pollution, or only non-conductive or noncorrosive pollution
Approvals
CE
RoHS Compliant
Yes
Ordering Information
Part Number
SST-PB3-SLC
SAP
1120160022
Description
SST™ PROFIBUS Scanner for AB SLC 500
Other related products:
Part Number
SAP
Description
SST-PB3-CLX-RLL
1120160018 SST™ PROFIBUS Scanner for AB ControlLogix
SST-PB3-CLX-RLL-CC
1120160023 SST™ PROFIBUS Scanner for AB ControlLogix
SST™ PROFIBUS Scanner for AB ControlLogix
1120160019
and CommDTM driver
SST-PB3-CLX-DTM