Salamander brochure

Salamander brochure
Powering up your shower
Salamander Pumped Shower Systems Limited
2-10 St Johns Street, Bedford MK42 0DH
Telephone: 0845 377 9160
Facsimile: 0845 377 9180
E-mail:
[email protected]
Issue 6/10
5880
The right pump for
your shower
Choose a Salamander pump and enjoy stimulating
power from your shower. Our comprehensive range of
pumps brings you the latest technology and an
assurance of quality and reliability – all at exceptional
value for money.
Salamander pumps are manufactured in the UK from
top quality components, the majority of which are
sourced from the EU. Each component is extensively
tested for long life and every pump is subject to strict
quality controls before it leaves our factory in
Sunderland. Our sophisticated use of technology,
which incorporates micro electronics and sensors in
the ESP range, delivers unrivalled performance that
retains pressure even under high flow rate conditions.
Contents
The right pump for your shower
Intelligent pump control
The Salamander pump range
Pump application chart
CT pumps
Right pumps
ESP CPV pumps
Identifying your plumbing system
S flange (Anti-aeration flange)
Hot water system supply – thermostatic valve
Anti-vibration couplers
PumpWise (Help, guidance and advice)
Warranty
General specification
Customer service/Training
1
3
4
5
7
11
15
20
20
21
21
22
23
24
25
All pumps come with installation guidelines and access
to our free technical helpline. When installed in
accordance with those guidelines we are confident
that you will enjoy ownership of your Salamander pump
for many years to come.
1
Intelligent pump
control
Salamander’s range includes pumps for any
domestic situation. Strong, durable and
user friendly, Salamander pumps are
designed to boost tank-fed hot and cold
water services to your home, providing you
with a powerful, invigorating shower. If you
need to increase the water supply to baths,
basins and other appliances as well, simply
choose one of the ESP or house pumps.
Salamander works to the highest
standards. Every pump in our range
is designed and engineered to
ensure a long, maintenance free life
and all are individually tested for
safety, performance and quality
of workmanship.
2
Our premium shower pumps – the ESP range
– enjoy the security and protection of an
electronic sensor. This technologically
advanced and sophisticated heart has been
created especially by Salamander and is
unique to our premium range of pumps.
An ESP pump will automatically identify
whether your water system is positive or
negative head and operate accordingly
(for a guide to identifying positive or
negative head installations, see page 20).
ESP pumps can be used on positive
or negative head systems
Single impeller
centrifugal
ESP 80 CPV
ESP 120 CPV
ESP 150 CPV
Twin impeller
centrifugal
ESP 50 CPV
ESP 75 CPV
ESP 100 CPV
ESP 140 CPV
Super boosters
ESP 80 CPV SB
ESP 120 CPV SB
ESP 150 CPV SB
(See page 15 for ESP pump details)
Micro electronic
technology
3
The Salamander pump range
Pump application chart
ESP 120 CPV 3.6 bar
Single impeller
Centrifugal
Twin impeller
Centrifugal
RHP 75 2.2 bar
ESP 150 CPV 4.5 bar
RGP 40 1.3 bar
ESP 75 CPV 2.2 bar
ESP 100 CPV 3.0 bar
RSP 50 1.5 bar
RHP 100 3.0 bar
ESP 140 CPV 4.3 bar
RGP 80 2.4 bar
RSP 75 2.2 bar
Negative head shower pumps
Super Boosters
RHP 140 4.3 bar
RGP 120 3.6 bar
RSP 100 3.0 bar
ESP 80 CPV SB 2.4 bar
ESP 120 CPV SB 3.6 bar
























§
§
§
§
§










   
   
   
   
   
   


§
§






















§
§

  
§
§ § §





































Individual hot/cold taps/bath
CT 75* CT 75+ 2.1 bar
1.5
2.1
1.6
2.5
1.3
2.4
3.6
1.5
2.2
3.0
1.5
2.2
3.0
4.3
2.4
3.6
4.5
1.5
2.2
3.0
4.3
2.4
3.6
4.5
Wash basins
CT 85* CT 85+ 2.5 bar
CT 50* CT 50+
CT 75* CT 75+
CT 55* CT 55+
CT 85* CT 85+
RGP 40
RGP 80
RGP 120
RSP 50
RSP 75
RSP 100
RHP 50
RHP 75
RHP 100
RHP 140
ESP 80 CPV
ESP 120 CPV
ESP 150 CPV
ESP 50 CPV
ESP 75 CPV
ESP 100 CPV
ESP 140 CPV
ESP 80 CPV SB
ESP 120 CPV SB
ESP 150 CPV SB
Toilets
RHP 50 1.5 bar
Pump
Whole house showers
ESP 50 CPV 1.5 bar
Positive
Negative
head
head
application application
Body jets (4 max)
ESP 80 CPV 2.4 bar
Bar
Champagne spray
NE
MODW
EL
For further PumpWise details see page 22.
Massage function
Positive head
Twin impeller
CT 50* CT 50+ 1.5 bar
NE
MODW
EL
Whole house pumps
Multi-function shower
Twin impeller
Centrifugal
Victorian can shower head
Single impeller
Centrifugal
Tel:
0845 377 9160
Fax:
0845 377 9180
Email: [email protected]
Conventional shower
CT 55* CT 55+ 1.6 bar
NE
MODW
EL
Washing machine/dishwasher†
NE
MODW
EL
Instant electric shower†
Twin impeller
Regenerative
If you need help in choosing the correct pump,
contact PumpWise.
Negative head shower pumps
and whole house pumps
To a combi boiler†
Single impeller
Regenerative
Typical pump applications
Instant electric water heater†
Positive head shower pumps
























 
  
 
  















  
  

 
 



  
  

 
 
* CT 50, 55, 75 and 85 are supplied with 15mm hoses with isolating
valves on the inlets. CT 50+, 55+, 75+, 85+, RSP 50 and RGP 40 are
supplied with 15mm hoses with isolating valves on the inlets and outlets.
All remaining pumps are supplied with 22mm hoses with isolating
valves on the inlets and outlets.
ESP 150 CPV SB 4.5 bar
† Via a header tank
§
4
May require RCM control modules
5
CT pumps
The N
EW
mode CT
availa ls,
bl
July 2 e from
010
Reliable entry level
regenerative shower pumps
The new range of CT shower pumps includes
even more features in its robust, installer
friendly design.
Push fit anti-vibration couplers
(AV) are supplied with all
Salamander pumps
installers, these compact pumps are
• For
now even easier to fit in tight spaces with
isolating valves as standard on inlet couplers.
users, the re-designed foot arrangement
• For
and improved switching will mean enhanced
reliability, performance and longevity
CT range gives an excellent boost to hot
• The
and cold water supplies to thermostatic
shower valves and can be used with
multi-function, conventional or Victorian
‘can style’ shower heads.
Push fit anti-vibration
couplers now with
isolating valves on the
inlets on the standard
CT range from July 2010.
Available in twin or single impeller variants,
performance ranges from 1.5 to 2.5 bar pressure.
The UK’s best selling shower
pumps just got even better!
6
7
Key
CT 50/50+/75/75+ twin impeller pumps
Regenerative, positive head
Tough, easy to fit general purpose
twin booster pumps with enhanced
design features, this range will
boost the hot and cold water
supplies to thermostatic or manual
shower mixer valves. Suitable for
a wide range of shower types and
heads. CT 50 and 75 are supplied
with AV couplers and isolating
valves as standard on inlet.
CT 50+ and 75+ are supplied with
AV couplers and isolating valves
as standard on inlets and outlets.
NEW
MOD
EL
CT twin
CT 50/50+ twin
CT 75/75+ twin
Applications
Twin shower specific
pumps
For conventional showers,
Victorian can style shower
heads and multi-function
showers.
For conventional showers,
Victorian can style shower
heads, multi-function
showers, massage function
or champagne spray.
Performance
Closed head pressure
Max amps/watts
50ft head (1.5 bar)
2.0 amps/480 watts
75ft head (2.1 bar)
2.1 amps/500 watts
Rating
Continuous
30 mins on/off
CT single
CT 55/55+ single
CT 85/85+ single
Applications
To boost supplies to a
variety of tank-fed
appliances
For washing machines and
dishwashers as well as
conventional showers,
Victorian can style shower
heads and multi-function
showers.
For washing machines and
dishwashers as well as
conventional showers,
Victorian can style shower
heads, multi-function
showers, massage function
or champagne spray.
Performance
Closed head pressure
Max amps/watts
55ft head (1.6 bar)
2.0 amps/450 watts
85ft head (2.5 bar)
2.1 amps/460 watts
Rating
Continuous
Continuous
Watercan
3 bar shower heads
Conventional spray
Body sprays
Multi-function massage
– champagne spray
Multiple body sprays
Shower head
?
?
?
?
CT 50
CT 55/55+/85/85+ single impeller pumps
Regenerative, positive head
NE
MODW
EL
An innovative range of single outlet
pumps with sophisticated switching
design and enhanced performance.
Designed to boost supplies to the
bathroom and the rest of the house,
these pumps will increase flow to
any tank fed appliance. CT 55 and 85
are supplied with AV couplers and an
isolating valve as standard on inlet.
CT 55+ and 85+ are supplied with
AV couplers and an isolating valve
as standard on inlet and outlet.
Shower head
?
?
?
?
CT 85
8
9
Right pumps
Reliable and smooth running
centrifugal shower pumps
A range of pumps designed for smooth
running with high levels of flow to boost
pressures to appliances throughout the
home, boosting supplies to wash basins,
baths and showers, whether the
requirement is for multi-function,
conventional or Victorian ‘can style’
shower heads. The centrifugal impeller
gives them quiet running with sustained
pressure and flow relative to other shower
pump types. Available in twin or single
impeller variants, performances range
from 1.5 to 4.3 bar pressure.
10
Push fit anti-vibration couplers
(AV) with isolating valves are
supplied with all Right and
ESP pumps
Isolating valve
Push fit anti-vibration
couplers help make pump
installation easier. See
page 21 for more details.
11
Key
Right shower pumps
Watercan
3 bar shower heads
Conventional spray
Body sprays
Multi-function massage
– champagne spray
Multiple body sprays
Positive head
Designed purely for
showers, these twinended pumps boost the
hot and cold supplies to
thermostatic or manual
mixer valves. Pumps are
capable of feeding multi
outlet applications.
Supplied with isolating
valve AV couplers.
RSP 100
Right pump
RSP 50 twin
RSP 75 twin
RSP 100 twin
Applications
Quiet running pumps for
showers. Not suitable to
boost toilets, washing
machines or individual
hot and cold taps.
Purpose made for one or
more Victorian can shower
heads or conventional
shower heads and
multi-function showers.
As the RSP 50 twin plus
showers ?with a massage
function or champagne
spray.
As RSP 50 and RSP 75 plus
up to four body jets.
Definitely the Right choice
for 3.0 bar shower heads.
Performance
Quiet*
Quiet*
Quiet*
Closed head pressure
Max amps/watts
50ft head (1.5 bar)
1.8 amps/430 watts
75ft head (2.2 bar)
3.2 amps/720 watts
100 ft head (3.0 bar)
4.0 amps/960 watts
Rating
Continuous
Continuous
Continuous
?
Shower heads
?
Right whole house pumps
Positive head
Designed specifically for whole
house systems, or just the
bathroom, these twin-ended
pumps are uniquely equipped to
handle single or multi outlet use,
ie: the hot or cold taps being
used individually or both at the
same time. Supplied with
isolating valve AV couplers.
RHP 75
?
?
Right pump
RHP 50 twin
Applications
Quiet running, high
performance pumps for
the whole house including
toilets, wash
? or
? basins
individual hot and cold
taps.
Houses and flats with low
resistance outlets.
Conventional showers,
Victorian can style showers,
whole house showers,
toilets, wash basins, baths,
individual hot and cold taps.
As the RHP 50 whole house The RHP 100 and RHP 140 have the same application
pump for houses and flats specifications as the RHP 50 and RHP 75 but can also
but also suitable for high
power showers with up to four body jets.
resistance
? outlets such as
?
multi-function showers and
showers with a massage
function or champagne
?
spray.
?
Performance
Quiet*
Quiet*
Quiet*
Quiet*
Closed head pressure
Max amps/watts
50ft head (1.5 bar)
1.8 amps/430 watts
75ft head (2.2 bar)
3.2 amps/720 watts
100 ft head (3.0 bar)
4 amps/960 watts
140 ft head (4.3 bar)
6 amps/1440 watts
Rating
Continuous
Continuous
Continuous
20 mins on/off
RHP 75 twin
Shower heads
?
Right single pumps
Positive head
A new and innovative range of
single outlet pumps. Compact
and smooth running with
sustained flow. Supplied with
isolating valve AV couplers.
?
?
RGP 40 single
Applications
The right single pump to
boost supplies to a
variety of appliances.
The RGP 40 is the ideal pump for a washing machine, dishwasher or a conventional
shower. The RGP 80 will also power Victorian can shower heads, multi-function
showers, massage functions and champagne sprays. As well as the applications already
listed the RGP 120 will power? up to four body jets.
Performance
Quiet*
Quiet*
Quiet*
Closed head pressure
Max amps/watts
43ft head (1.3 bar)
2.0 amps/480 watts
80ft head (2.4 bar)
2.4 amps/580 watts
115ft head (3.6 bar)
2.7 amps/650 watts
Rating
Continuous
Continuous
Continuous
?
RHP 140 twin
?
?
RGP 80 single
?
?
RGP 120 single
?
Shower heads
12
RHP 100 twin
?
Right pump
?
RGP 80
?
?
?
* We state ‘quiet’ on our
centrifugal range of
pumps as they are quiet
in operation relative to
other shower pumps
available. Pumps are
mechanical in operation
and the need to move
water in volume or at
high pressure will
generate some
background noise.
13
ESP CPV pumps
Reliable and smooth running centrifugal
pumps that automatically detect
and adapt to positive or
Automatic pump protection and
negative head installations
simple LED indication
Salamander’s premium range of shower and
whole house pumps, these pumps take away the
confusion of which pump to buy for the respective
plumbing system, as they will automatically detect
whether the installation is in positive or negative head.
The ESP CPV pumps are a result of extensive research
to develop these advanced pumps that incorporate
micro-electronic technology and sensors. Quiet running
relative to other shower pump types, they are reliable
and high in quality.
The first intelligent shower pump with electronic
system protection (ESP), can be used for appliances
throughout the home, boosting supply to wash basins,
baths and showers. The high pressure variants can also
be used to boost supplies to body jets and steam
cabinets. Available in twin or single impeller variants,
performances range from 1.5 to 4.5 bar pressure.
Cold
N
Negative head
operation
P
Positive head
operation
1
System hunting
protection
2
Dry run
protection
3
Supply water
temperature
protection
Clear indicators on the
top of the pump show
the electronic system
protection is working
correctly.
L.E.D. indication
Hot
Pressure vessel
14
15
Key
ESP 50 CPV and ESP 75 CPV twin
Watercan
3 bar shower heads
Conventional spray
Body sprays
Multi-function massage
– champagne spray
Multiple body sprays
Positive and/or negative head systems
Designed specifically for one or
two bathroom systems where
there is a need to boost baths,
basins or showers which may be
above and/or below the cold
water storage tank(s).
ESP CPV twin
ESP 50 CPV twin
ESP 75 CPV twin
Applications
For flats and houses
where the requirement is
for a positive and/or
negative head pump.
For tank fed shower and/or
whole house systems in
flats and houses where the
pressure requirement is up
to 1.5 bar (30-42ft head).
For conventional showers,
Victorian can style showers,
multi-function showers,
whole house showers,
toilets, wash basins and
individual hot/cold
taps/bath.
As the ESP 50 CPV – plus
multiple shower systems
where the pressure
requirement is up
to 2.2 bar (65-75ft head).
Also suitable for showers
with a massage function or
champagne spray.
Performance
Quiet*
Quiet*
Closed head pressure
Max amps/watts
50ft head (1.5 bar)
1.8 amps/430 watts
75ft head (2.2 bar)
3.2 amps/720 watts
Rating
Continuous
Continuous
ESP 100 CPV twin
ESP 140 CPV twin
Applications
As ESP 50/75 CPV above
but where there may also
be shower columns,
steam cubicles or body
jets/sprays.
As ESP 75 CPV above but
also where there may be up
to four body jets in the
system where the pressure
requirements is up to
3.0 bar (100ft head).
As ESP 100 CPV and where
the pressure requirement
is up to 4.3 bar typically in
pre-formed shower
columns and cubicles.
Performance
Quiet*
Quiet*
Closed head pressure
Max amps/watts
100ft head (3.0 bar)
4 amps/960 watts
142ft head (4.3 bar)
6 amps/1440 watts
Continuous
20 mins on/off
Typically – flats, loft and barn
conversions. Supplied with
isolating valve AV couplers.
ESP 75 CPV twin
Shower head
?
?
ESP 100 CPV and ESP 140 CPV twin
Positive and/or negative head systems
As ESP 50 CPV and ESP 75 CPV
twin above, but also for systems
where there is a need for greater
performance or flow, e.g. shower
columns, steam cubicles
and multiple body sprays.
Supplied with isolating
valve AV couplers.
ESP CPV twin
?
?
Rating
Shower head
?
?
ESP 100 CPV twin
?
?
?
16
?
?
?
* We state ‘quiet’ on our
centrifugal range of
pumps as they are quiet
in operation relative to
other shower pumps
available. Pumps are
mechanical in operation
and the need to move
water in volume or at
high pressure will
generate some
background noise.
17
Key
ESP 80 CPV and ESP 120 CPV single
Watercan
3 bar shower heads
Conventional spray
Body sprays
Multi-function massage
– champagne spray
Multiple body sprays
Positive and/or negative head systems
These single pumps boost
supplies to a variety of
appliances from tank-fed
systems, and are suitable for
both positive and negative head
systems. Selection should be
based on pressure requirements.
Supplied with isolating valve
AV couplers.
ESP CPV single
ESP 80 CPV single
Applications
To boost tank fed supplies to combination boilers, instantaneous electric showers,
instantaneous electric water heaters, and washing machines/dishwashers – according
to inlet pressure requirements. Consult PumpWise for help selecting the correct
pump, see page 22. These pumps will also power conventional showers, Victorian
shower heads, multi-function showers, showers with massage functions or champagne
spray. The ESP 120 CPV and ESP 150 CPV will also power up to four body jets.
ESP 120 CPV single
ESP 150 CPV single
?
Performance
Quiet*
Quiet*
Quiet*
Closed head pressure
Max amps/watts
80ft head (2.4 bar)
2.4 amps/580 watts
120ft head (3.6 bar)
2.7 amps/650 watts
150ft head (4.5 bar)
5 amps/750 watts
Rating
Continuous
Continuous
30 mins on/off
Shower head
ESP 80 CPV single
ESP CPV super boosters
?
?
?
?
?
Positive and/or negative head systems
The choice of super booster is
determined by establishing the
pressure required at the outlets.
These boosters are suitable for
both positive and negative head
systems. Supplied with isolating
valve AV couplers.
ESP CPV SB
ESP 80 CPV SB
Applications
Created to meet the
requirements of those
who live in larger houses
or whose idea of a really
good shower is a total
deluge.
Each Super Booster comprises two single pumps, one each to independently boost tank
fed hot and cold water services. These pumps can be positioned together or remotely
one from the other. Application specification is the same as single versions above.
Performance
Quiet*
Quiet*
Quiet*
Closed head pressure
Max amps/watts
80ft head (2.4 bar)
1.8 amps/430 watts
120ft head (3.6 bar)
3.2 amps/720 watts
150ft head (4.5 bar)
5 amps/750 watts
Rating
Continuous
Continuous
30 mins on/off
Shower head
ESP 120 CPV super boosters
?
ESP 120 CPV SB
ESP 150 CPV SB
?
?
?
?
?
?
* We state ‘quiet’ on our
centrifugal range of
pumps as they are quiet
in operation relative to
other shower pumps
available. Pumps are
mechanical in operation
and the need to move
water in volume or at
high pressure will
generate some
background noise.
?
18
19
Identifying your plumbing system
Hot water supply blending valve
Positive head systems (Gravity fed)
The hot water supply blending valve is designed to protect
booster pumps fitted to systems where the stored domestic
hot water temperature is uncontrolled e.g. Aga, solid fuel
appliances or automatic boilers very crudely controlled by
the boiler thermostat.
Several different plumbing systems are used in
UK homes, the most common of which is a gravity
fed system – detailed in the schematic diagram.
In these type of systems there is usually a cold
water tank in the loft with a hot water tank below
it, probably in an airing cupboard.
Positive head system(Gravity fed)
Usable capacity minimum
50 gallons per bathroom
and 30 gallons per en suite
Positive head
If your shower is not forceful enough due to
insufficient water pressure, this can be easily
boosted by the installation of a pump. The
diagram shows where the pump should be
situated for gravity fed systems.
Vent
and other
services
Negative head systems (Gravity fed)
Negative head systems are where poor natural
flow of water goes to the shower head because it
is above the height of the base of the cold water
tank or there is limited height between the base
of the cold water tank and the shower head. Most
instances of negative head systems occur in loft
conversions or where the cold water tank sits on
the joists in the loft. See page 15 for our range of
negative head pumps.
Air vents, both
hot and cold
The hot
connection
must be via
an approved
side or top
entry flange
MAX
65°C
possible a negative
Non return valve head pump may be
Hot outlet ONLY required
Outlets
C
Negative head
Negative
head
When
the
distance
If the distance
between the
the cold
between
coldwater
storage
tank and
the
water
storage
tank
shower
head is 2 feet or
and
the shower
less, is
or2
when
head
feetthe
or
natural
is poor or
less
it isflow
possible
than 2 head
litres per
a less
negative
minimum
mixed it is
pump
is required
H
Usable capacity minimum
50 gallons per bathroom
and 30 gallons per en suite
Vent and other
services
TYPICAL PIPEWORK ARRANGEMENT
For systems without a flange – will risk
aeration of the supply water to the pump.
Diagram E
Positive
head
Vent
and other
services
Can be off the vent
if the distance is
at least 1 metre
MAX
65°C
Outlets
C
Outlets
H
Inlet
Hot water supply blending valve controller is
factory set at 55-60°C
2 feet or less
possible negative head
Fit an
equilibrium
ball valve
Surrey or
No Stop
Essex flange
Inlet C
Inlet
Usable capacity
minimum 50 gallons
per bathroom
The hot
connection
must be via
an approved
side or top
entry flange
see col. 3 page 10
H
Inlet
Washing
machine
Example of a regenerative twin with hot water supply
blending valve protection
S flange
Salamander’s uniquely different top entry
22mm compression
DZR cylinder flange
outlet to the pump
Anti-vibration
couplers
Typical pipework
arrangement
Systems without a
flange will risk
aeration of the supply
water to the pump.
MAX
65°C
All Salamander pumps are supplied with anti-vibration
couplers (AV) in order to limit the transfer of motor and pump
CYLINDER
vibration to the associated pipe work.
Cold feed
to cylinder
1" BSP female adaptor to
facilitate connection to both
female and male outlet cylinder
28mm compression fitting includes
a 28mm x 22mm reducing set
•
TYPICAL PIPEWORK ARRANGEMENT
Plumbing
is not anwithout
exact science
and–aeration
For systems
a flange
will riskof
the supply
water
to
showers
and
other
outlets
is a
aeration of the supply water to the
pump.
common problem.
•
When a pump is fitted to boost the supplies from the
cold water storage tank and from the cylinder to showers,
baths and basins the risk of aeration is increased
many times.
Aeration – aerated supply water to pumps and to showers
and other outlets means an increased risk of:
MAX
Unnecessary, perhaps
65°Csudden temperature fluctuation at
the shower or other outlets.
•
•
•
•
A noisy pump.
Accelerated degradation of the pump’s mechanical shaft
seals eventually to leak.
Premature pump breakdown.
A correctly fitted approved cylinder flange will mitigate if not
prevent these risks.
20
Cold feed to cylinder
The beneficial effect of AV couplers is lost if they are bent or
twisted on installation.
Pump
Pump
Each pump whether single or twin pump is supplied with
one or two each straight and angled AV couplers. This
To Pump of the
arrangement of couplers facilitates the connection
supply pipe work from any direction.
To vent
S flange
The S flange will
encourage
aeration to follow
a natural path to
the vent and
prevents aerated
supply water
being drawn into
the pump.
CT 50, 55, 75 and 85 are supplied with 15mm hoses with
isolating valves on the inlets. CT 50+, 55+, 75+, 85+, RSP 50
and RGP 40 are supplied with 15mm hoses with isolating
valves on the inlets and outlets. All remaining pumps are
supplied with 22mm hoses with isolating valves on the inlets
and outlets.
S flange
HOT WATER
CYLINDER
To pump
21
PumpWise
Warranty
An initiative to help customers
Two years warranty
PumpWise is the cornerstone of
Salamander’s support service to
customers and the means by which
our customers are guaranteed –
Salamander customers benefit from a two
year warranty. This warranty will operate
from date of purchase and is subject only
to the installation guidelines being
followed correctly.
• Selection of the right pump for the job
• The avoidance of installation pitfalls
• A third year’s warranty FREE
Selecting the right pump for the job
Third year warranty FREE
We offer technical assistance, guidance or
advice to anyone who asks. Contact our
sales department.
Eliminate the risk of an incorrect
installation
If your installation is not straightforward
or if you have any reservation or doubts
contact our technical department.
Third year’s warranty is
completely free
To qualify for the third year’s warranty all
you have to do is register and follow the
engineer’s advice. Contact our technical
department.
For PumpWise help, guidance or
advice simply call
0845 129 5010
Under the PumpWise Scheme customers
who consult Salamander and register the
pump by phone immediately after
installation, and who implement our
recommendations, will benefit from a
third year warranty FREE.
Warranty
The Extended Warranty Scheme
Your pump warranty can be extended for an
additional three years.
The Extended Warranty Scheme exists to
protect customers from unexpected or
unforeseen pump breakdown.
Under the Extended Warranty Scheme
customers are guaranteed a no-quibble
replacement pump FREE for a further
three years. Plus the years of the standard
or PumpWise warranty whichever is
applicable.
Participation in the Extended Warranty
Scheme is activated on completion of a
direct debit mandate for payment of a
nominal designated amount. Call sales on
0845 377 9160 and ask for details.
(09.00-17.00 weekdays)
Sales:
0845 377 9160
Technical: 0845 129 5010
Fax:
0845 377 9180
E-mail: [email protected]
[email protected]
On-site nationwide support
To resolve any on-site technical issues
contact us. If required we can arrange for
one of our Salamander service engineers
to visit the installation.
A Salamander engineer will resolve your
problem quickly over the phone, or if that’s
not possible, arrange an on-site visit.
22
23
General specification
Applications
Initiation
All Salamander pumps are designed to boost low pressure
hot and cold supplies from tank-fed services. When
supplies from a water heater or a combination boiler are
to be boosted contact the Salamander PumpWise*
helpline 0845 129 5010 for guidance.
ESP CPV pumps are fully automatic for both positive and
negative head systems. All other pumps require a natural
flow of at least 1 litre per minute from a hot or cold outlet
for automatic operation in positive head systems.
Customer service
Sales
Technical advice
Our team of responsive and supportive
internal sales operators are on hand to
advise on all enquiries relating to sales
orders and advice on which pump best
fits your application.
Our team of friendly and knowledgeable
technical advisers, are at the end of the
phone to answer any queries of a technical
nature whether pre or post installation.
For sales help
Tel: 0845 377 9160
Fax: 0845 377 9180
Email: [email protected]
For technical help
Tel:
0845 129 5010
Email: [email protected]
Temperature
Voltage
Maximum fluid temperature 65ºC. ESP CPV pumps will
automatically stop running if the hot water temperature
exceeds acceptable limits.
220-240 volts 50 Hz.
Motor type
Capacitor start and run induction type motor with
stainless steel shaft and in-built resetting thermal
protection (complies with BS5000 part 11).
Pump materials
All moulded components are manufactured from WRAS
approved Acetal Copolymer and Glass Coupled
Polypropylene.
Maximum head
ESP 50 CPV
5 metres
CT 50/50+/55/55+/75/75+/85/85+ 15 metres
All other pumps
10 metres
Pumps fitted with RCM3 maximum 3 metres static head.
Anti-vibration couplers
CT 50, 55, 75 and 85 are supplied with 15mm hoses with
isolating valves on the inlets. CT 50+, 55+, 75+, 85+,
RSP 50 and RGP 40 are supplied with 15mm hoses with
isolating valves on the inlets and outlets. All remaining
pumps are supplied with 22mm hoses with isolating
valves on the inlets and outlets.
Mechanical seals
Single Pumps – continuous. Except for ESP 150 CPV
single and ESP 150 CPV SB which are 30 mins on/off.
Twin pumps continuous except CT 75 and CT 75+ which
are 30 mins on/off, and RHP 140 and ESP 140 CPV which
are 20 mins on/off.
All Salamander pumps are fitted with a mains lead and an
appropriately fused moulded three-pin plug, except for
the ESP 140 and RHP 140.
Continuous improvement
The company operate a policy of continuous development
and reserves the right to change any of the specifications
of its products without prior notice. All information data
and illustrations given in this leaflet may be subject to
variation.
Standards and approvals
Splash proof rating IPX2.
Complies with the requirements of current British and
European safety standards for household and similar
electrical appliances.
Meets with Compliance with European Community
Directives (CE).
Rotary mechanical face seals comprise a carbon rotary
element and a ceramic counter face. This combination is
resistant to mineral deposits and to abrasion.
Due to continuous improvement and updating,
specifications may be altered without prior notice.
Connections
* PumpWise – A Salamander initiative to help customers
and to provide a support service which is second to none.
3
/4" BSP male.
24
Electrical rating
Training
We offer dedicated training with
our Training Manager for Installers,
Merchants, Showroom Staff and
College’s which can be arranged by
calling 0845 377 9160.
Do you need help selecting the right
pump for your application? Then either
call Pumpwise on 0845 377 9160 and
they will walk you through a pump
selection process or they can send you
our new interactive CD.
25
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement