East Coast Datacom UDC-ME Universal Data Converter Operations manual
The East Coast Datacom UDC-ME is a Universal Data Converter designed to allow two DTE devices, like routers, to communicate within close proximity. It transmits data bi-directionally at clock rates ranging from 1.2k to 3.072Mbps, with the clocking and signal crossover handled internally. The UDC-ME is equipped with two interface slots that support various serial interface cards, such as RS-232, RS-422/449, RS-530, X.21, V.35, and HSSI.
Advertisement
Advertisement
TABLE OF CONTENTS
CHAPTER 1 - INTRODUCTION
. . . . . . . . . . . . . . . . . . . . . .
1.1 FUNCTIONAL DESCRIPTION
. . . . . . . . . . . . . . . . . . .
Page 1
Page 1
CHAPTER 2 - PRODUCT OVERVIEW
. . . . . . . . . . . . . . .
Page 2
2.1 FRONT PANEL INDICATORS
. . . . . . . . . . . . . . . . . . . .
2.2 INTERNAL SWITCHES
. . . . . . . . . . . . . . . . . . . . . . . . . .
2.3 REAR PANEL POWER CONNECTOR
. . . . . . . . . . . .
2.4 REAR PANERL DATA INTERFACE PORTS
. . . . . .
2.5 CLOCKING
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.6 DATA INTERFACES
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 2
Page 2
Page 2
Page 2
Page 2
Page 2
2.7 EXTERNAL CLOCK OPTION
. . . . . . . . . . . . . . . . . . . .
2.8 CONTROL SIGNAL FORCING
. . . . . . . . . . . . . . . . . . .
Page 2
Page 3
2.9 DATA INTERFACE REMOVAL
. . . . . . . . . . . . . . . . . . .
Page 3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHAPTER 3 - INSTALLATION
. . . . . . . . . . . . . . . . . . . . . .
Page 4
3.1 VOLTAGE SELECTION
. . . . . . . . . . . . . . . . . . . . . . . . .
3.2 VOLTAGE SELECTION FUSES
. . . . . . . . . . . . . . . . . .
3.3 POWER CONNECTION
. . . . . . . . . . . . . . . . . . . . . . . . .
3.4 DEFAULT CONFIGURATION SWITCH SETTINGS
3.5 DATA PORT CONNECTIONS
. . . . . . . . . . . . . . . . . . . .
Page 4
Page 4
Page 4
Page 5
Page 5
3.6 SWITCH SETTINGS
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.1 DIP SWITCHES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 5
Page 5
3.7
EXTERNAL CLOCK OPTION . . . . . . . . . . . . . . . . . . . . . .
Page 5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.0 - APPENDIX
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1 STRAP CHART CLOCK RATES
. . . . . . . . . . . . . . . . .
4.1 STRAP CHART CONTROL SIGNALS
. . . . . . . . . . . .
4.3 TECHNICAL OVERVIEW
. . . . . . . . . . . . . . . . . . . . . . . .
5.0 - TECHNICAL SPECIFICATIONS
. . . . . . . . . . . . . . . .
Page 6
Page 7
Page 7
Page 8
Page 9
OPERATIONS MANUAL
UNIVERSAL DATA CONVERTER
Modem Eliminator
UDC-ME
11 January 2011
FOR TECHNICAL SUPPORT CALL:
East Coast Datacom, Inc.
245 Gus Hipp Blvd., STE 3
Rockledge, FL 32955 USA
TEL: (321) 637-9922
FAX: (321) 637-9980
E-mail: [email protected]
Manufactured By
:
East Coast Datacom, Inc.
WWW.ECDATA.COM
Manual Part
Number 184054
Rev - A
UDC-ME INSTALLATION AND OPERATIONS MANUAL
SAFETY WARNING
WARNING
Always observe standard safety precautions during installation, operation and maintenance of this product. To avoid the possibility of electrical
shock, be sure to disconnect the power cord from the power source
before servicing the device. Line voltages are present within the device when the power cord is attached to the device.
DO NOT attempt to repair this device. Only qualified service personel
can service this device.
WARNING
For AC powered devices which have 3 conductor power plugs (L1, L2
&GND or Hot, Neutral & Safety/Protective Ground), the wall outlet (or socket) must have an earth ground.
PROPRIETARY NOTICE
The information contained herein is proprietary to East Coast Datacom, Inc. Any reproduction or redistribution of this publication, in whole or in part, is expressly prohibited unless written authorization is provided by East Coast Datacom, Inc.
WARRANTY NOTICE
WARRANTIES: East Coast Datacom, Inc.(hereafter referred to as E.C.D.) warrants that its equipment is free from any defects in materials and workmanship. The warranty period shall be three (3) years from the date of shipment. E.C.D.'s sole obligation under its warranty is limited to the repair or replacement of defective equipment, provided it is returned to E.C.D., transportation prepaid, within a reasonable period. This warranty will not extend to equipment subjected to; lightning strikes, electrical surges, water damage, misuse, alterations, mishandling (dropped and damaged) or repair not made by E.C.D. or authorized by E.C.D. in writing.
PUBLICATION NOTICE
This manual has been compiled and checked for accuracy. The information in this manual does not constitute a warranty of performance. E.C.D. reserves the right to revise this publication and make changes from time to time in the content thereof. E.C.D. assumes no liability for losses incurred as a result of out-of-date or incorrect information contained in this manual.
UDC-ME INSTALLATION AND OPERATIONS MANUAL
CHAPTER 1 - INTRODUCTION
1.1 FUNCTIONAL DESCRIPTION
The UDC-ME allows two DTE devices (such as routers) to communicate within proximity of each other. The UDC-ME transmits data bi-directionally at clock rates of 1.2k up to 3.072Mbps between
DTE devices. All clocking and signal crossover are provided within the UDC-ME. The unit is equipped with two interface slots that allow a host of serial interface cards to be utilized. The serial interface cards available are RS-232, RS-422/449, RS-530, X.21, V.35 and HSSI. The Serial Interface cards are interchangeable and may be mixed such as RS-232 to V.35 thus eliminating the need for an interface converter or changing expensive serial cards on a DTE device such as a router.
The UDC-ME is also an excellent choice for testing router-to-router connections via the serial ports.
The unit is an ideal choice for interconnecting your LAN or legacy mainframe equipment.
Installation is fast and simple by setting the internal switches for Clocking, Carrier Operation and
RTS to CTS delay. The UDC-ME has status LED's for each attached DTE device which allows the user to visually confirm the presence of clock and control signals. Also included are options for data or clock inversion.
The UDC-ME utilizes state of the art digital CMOS technology to provide a feature filled product at a very affordable price. Our Field Programmable Gate Array (FPGA) design has allowed us to offer this product with a wide selection of clock rates. This design approach has also reduced the amount of clock jitter for high speed transmissions.
The UDC-ME is housed in a sturdy metal enclosure and operates on 110/220VAC or optional -48V
DC power. Typical MTBF figures are in excess of 150,000 hours of operation.
The UDC-ME has a three year warranty and a 24 hour turnaround on warranty repairs
.
Router or
Legacy DTE
UDC-ME Modem Eliminator
Rates of 1.2k to 3.072Mbps
Router or
Legacy DTE
TYPICAL APPLICATION
Figure 1.1
Page 1
UDC-ME INSTALLATION AND OPERATIONS MANUAL
CHAPTER 2 - PRODUCT OVERVIEW
2.1 FRONT PANEL INDICATORS
A Green LED marked PWR illuminates when AC Power has been applied. Two adjacent sets of Green LEDs, one for PORT A and another for PORT B, illuminate in union with individual port control signal activity. Both Port A and Port B indicators flash in union with
Port A and Port B data interfaces(see section 2.4 Data Interfaces).
2.2 INTERNAL SWITCHES
The UDC-ME has three(3) dip switches. The switches are marked SW1, SW2 and SW5.
Switch SW1 allows the user to set the Clock Rate(s). Switches SW2 and SW5 allow the user to Invert the Clock and force control Signals.
2.3 REAR PANEL POWER CONNECTOR
Located on the back or rear of the product you will find an IEC POWER RECEPTACLE.
The supplied power cord plugs into this receptacle. This receptacle also contains a fuse drawer. Two (2) fuses are located in this compartment. For 110 VAC +/- 10% operation the unit is equipped with slow blow 160ma Fuses. For 220 VAC +/- 10% operation the unit is equipped with slow blow 80ma Fuses.
2.4 REAR PANEL DATA INTERFACE PORTS
Located adjacent to the IEC Power receptacle are the DATA INTERFACE PORTS. The ports are metal stamped PORT A and PORT B. The data interface modules plug into the
UDC-ME main printed circuit board through these openings. The top two screws on the interface module hold the card into place. The front panel Port A and Port B indicators flash in union with Port A and Port B data interfaces.
2.5 CLOCKING
The UDC-ME allows clock rates from 1.2k to 3.072Mbps. The unit has 32 selectable clock rates.
2.6 DATA INTERFACES
The UDC-ME has a host of available DATA INTERFACES comprised of RS-232, V.35,
RS-422/449, RS-530, X.21 and TTL. Each interface module is available in a DCE configuration, the true EIA or ITU recommended connector and female gender is provided.
The V.35 interface modules are MR-34 male, with factory optional DB-25 female. This
option can reduce cabling costs.
2.7
EXTERNAL CLOCK REFERENCE
The UDC-ME allows external timing(if applicable) for applications requiring such via SW2 for either Port A or Port B.
Page 2
UDC-ME INSTALLATION AND OPERATIONS MANUAL
2.8
CONTROL SIGNAL FORCING
The UDC-ME Control Signals are forced on the main printed circuit card located at switch position SW5. ONLY use the Dip Switch to force control signals.
When forcing control signals via SW5, you should see the control signal LED light illiminate on Channel A or Channel B.
While each Data Interface Module has straps(3 pin header) that force select control signals, those straps are for other East Coast Datacom products. It will not harm the unit, but utilizing them can give false LED lights or operation.
2.9
DATA INTERFACE REMOVAL
Disconnect the AC power source from the UDC-ME and disconnect the users data cables from the Data Interface Module(DIM). Located on back panel of the UDC-ME are PORT A and PORT B. Each DIM is plugged into and out of these ports through mating connectors.
Remove the top cover using a phillips screwdriver, then remove the top two screws of the
DIM. Gently pull the module from the UDC-ME housing. It may be easier to hold the edges of the DIM and rock the DIM back and forth as you pull the DIM out of the socket.
INTERFACE
MODULE
SCREWS(2)
REAR PANEL
DATA INTERFACES
PORT B
Page 3
PORT A
110/220VAC
SWITCH
UDC-ME INSTALLATION AND OPERATIONS MANUAL
CHAPTER 3 - INSTALLATION
CAUTION: Disconnect Power Before Servicing
ATTENTION: Couper Le Courant Avant l' Entretien
VORSICHT: Befor Deckung Abnehmen Mach Strom Zu
3.1 VOLTAGE SELECTION
It is very important to check that the unit is set to the correct voltage setting for your application before applying AC power. Located on the rear of the unit you will find a rotary
110/220 VAC switch. Using a coin or small screwdriver, gently turn the switch to the appropriate power position as required for your installation (110 or 220 VAC).
3.2 VOLTAGE SELECTION FUSES
Located on the back or rear of the product you will find an IEC Power receptacle. This receptacle contains a fuse drawer. Two (2) fuses are located in this compartment. For 110
VAC +/- 10% operation the unit is equipped with slow blow 5 x 20mm 160ma Fuses, E.C.D.
Part # 714000. For 220 VAC +/- 10% operation the unit is equipped with slow blow 5 x
20mm 80ma Fuses, E.C.D. Part # 714001. Spare fuses may be purchased by calling East
Coast Datacom or by contacting the fuse manufacturer: Little Fuse www.littlefuse.com or
Shurter, Inc. at www.schurter.com
Little Fuse Part #'s are: 160ma = 218.160 and 80ma = 218.080
Schurter, Inc. Part #'s are: 160ma = 034.3109 and 80ma = 034.3106
3.3 POWER CONNECTION
Before connecting the UDC-ME to an AC power source the top cover should be installed with the supplied #4-40 screws. AC power is supplied to the unit through a 2.3m (6.6 ft) cord terminated by a grounded 3-prong plug. Select an appropriate location accessible to and within four to five feet of an AC outlet. The AC Power
FUSE
source MUST be grounded or the units warranty will be void.
DRAWER
Power Connection
Figure 3-1
110 / 220 VAC
SWITCH
IEC POWER
CONNECTOR
Page 4
UDC-ME INSTALLATION AND OPERATIONS MANUAL
3.4 DEFAULT CONFIGURATION SWITCH SETTINGS
The UDC-ME is factory configured as follows:
1) Clock Source - Internal
2) Control Signals - All Signals Passed if present
3) Sync Clock Rate - 1.2k
4) Chassis to Signal GND - Not Connected
If your system application requires one or more of the default settings to be changed, this is accomplished by removing the top cover to change Dip Switches SW2-SW5 or to connect chassis to signal ground.
3.5 DATA PORT CONNECTIONS
Before applying AC Power to the unit, the users cabling to the UDC-ME Data Interfaces should be connected. Straight through shielded cables should be used. PORT A must
always have a DCE interface module plugged into the port and connect to a DTE device.
PORT B must always have a DTE interface module plugged into the port and connected to a DCE device.
3.6 SWITCH SETTINGS
3.6.1 DIP SWITCHES
The UDC-ME has three(3) dip switches. The switches are marked SW1, SW2 and SW5.
Switch SW1 allows the user to set the Clock Rate(s). Switches SW2 and SW5 allow the user to Invert the Clock and force control Signals.
3.7 EXTERNAL CLOCK OPTION
The UDC-ME allows external timing(if applicable) for applications requiring such via SW2 for either Port A or Port B.
Page 5
UDC-ME INSTALLATION AND OPERATIONS MANUAL
4.0 - APPENDIX
4.1 STRAP CHART
SME-ME BAUD RATE SETTING CHART
384,000
512,000
768,000
1,024,000
1,280,000
1,472,000
1,536,000
1,544,000
1,920,000
1,984,000
2,048,000
3,072,000
38,400
48,000
56,000
57,600
64,000
72,000
96,000
128,000
192,000
256,000
Switch settings SW1
1 2 3 4
1,200 Unused Unused Unused OFF
2,400
4,800 "
"
"
"
"
" OFF
OFF
7,200
9,600
14,400
16,000
19,200
28,800
32,000
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
OFF
OFF
OFF
OFF
OFF
OFF
OFF
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
7
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
6
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
8
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Page 6
UDC-ME INSTALLATION AND OPERATIONS MANUAL
Internal Clock Generator
External Clock f/Port A
CTS Port A follows RTS
Force CTS Port A ON
CTS Port A Delay = 0 mS
CTS Port A Delay = 6 mS
CTS Port A Delay = 12 mS
CTS Port A Delay = 24 mS
Internal Clock Generator
External Clock f/Port B
CTS Port B follows RTS
Force CTS Port B ON
CTS Port B Delay = 0 mS
CTS Port B Delay = 6 mS
CTS Port B Delay = 12 mS
CTS Port B Delay = 24 mS
SW2: 1
OFF
OFF
ON
ON
OFF
ON
OFF
ON
2 3 4 5
OFF OFF
OFF ON
ON OFF
ON ON
6 7 8
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Port A TXC Normal
Port A TXC Inverted
Port A RXC Normal
Port A RXC Inverted
Port B TXC Normal
Port B TXC Inverted
Port B RXC Normal
Port B RXC Inverted
Port A DCD Follows Port B CTS
Port A DCD Always ON
Port A DSR Follows Port B DTR
Port A DSR Always ON
Port B DCD Follows Port B CTS
Port B DCD Always ON
Port B DSR Follows Port B DTR
Port B DSR Always ON
SW5: 1
OFF
ON
2
OFF
ON
3
OFF
ON
4
OFF
ON
Bold denotes factory default settings ***
5
OFF
ON
6
OFF
ON
7
OFF
ON
8
OFF
ON
***
Page 7
4.2 UNIT OVERVIEW
UDC-ME INSTALLATION AND OPERATIONS MANUAL
POWER SUPPLY
POWER ENTRY
& FUSE DRAWER
WARNING
PORT A
PORT B
DIP SWITCHES
SW1, SW2 & SW5
Page 8
UDC-ME INSTALLATION AND OPERATIONS MANUAL
Warranty
Three Years, Return To Factory
Application
Interconnection of two DTE (Terminal) devices located within proximity of each other
Capacity
Two (2) DTE's
ORDERING INFORMATION
Main Unit Part Number: 189000
Model: UDC-ME
Description: UDC Modem Eliminator, rates of
1.2k to 3.072M
Serial Data Interface
RS-232, RS-422/449, RS-530, X.21, V.35 and
HSSI
Data Format
Data Transparent at all Data Rates
Inversion Option
Data Inversion or Clock Inversion
Data Rates
1.2k, 2.4k, 4.8k, 7.2k, 9.6k, 14.4k, 16k, 19.2k,
28.8k, 32k, 38.4k, 48k, 56k, 57.6k, 64k, 72k,
96k, 128k, 192k, 256k, 384k, 512k, 768k,
1.024M, 1.280M, 1.472M, 1.536M, 1.544M,
1.920M, 1.984M, 2.048M, 3.072M
Serial Interface Cards, Two Cards Required
Per UDC-ME, may be the same card twice or any combination.
PART NUMBER
129014
129010
129011
129012
129013
151028
SERIAL CARD
RS-232 DCE I/M,
V.35 DCE I/M,
RS-530 DCE I/M,
RS-422/449 DCE
X.21 DCE I/M,
HSSI DCE I/M, 50
Indicators
Power, TXD, RXD, TXC, RXC, RTS, CTS,
DTR, DCD
Surge Protection
Main power supply
INCLUDED WITH EACH UNIT:
1) Operations Manual
2) U.S.A. Grounded Power Cord, Part #
713015
3) Optional Power Cords
A) United Kingdom, Part # 713016
B) Continental Europe, Part # 713017
C) Other: Specify Country on Purchase
Order
Power Source
AC Mains: 100-120 to 200-220VAC @10%,
50/60Hz, 0.16/0.08A, external 110/220 volt select switch, IEC Power Inlet, (2) 5mm Fuses
DC Mains: DC Voltage, Input Range of -36 to
-72vdc Current Draw at 48vdc: 75ma @
3.6watts
OPTIONAL ACCESSORIES
1) Spare Data Center Fuses
A) 160ma Fuse, Qty (2) Part # 714000
B) 80ma Fuse, Qty (2) Part # 714001
For further detailed technical information on this product, contact East Coast Datacom
Technical Assistance toll free at (800)
240-7948
Environmental
Operating Temperature....32º to 122º F (0º to 50º C)
Relative Humidity.............5 to 95%
Non-Condensing
Altitude............................0 to 10,000 feet
OTHER EAST COAST DATACOM
PRODUCTS
Dimensions
Height ....... 1.75 inches (4.44 cm)
Width ........ 9.00 inches (20.86 cm)
Length ....... 9.00 inches (22.86 cm)
MODEM AND PORT SHARING DEVICES
INTERFACE CONVERTERS
SIGNAL REGENERATORS
LINE DRIVERS
Weight
2 pounds (0.914Kg)
Page 9
Advertisement
Key Features
- Bi-directional data transmission
- Clock rates from 1.2k to 3.072Mbps
- Two interface slots for various serial cards
- Interchangeable interface cards
- LED indicators for port status
- Data and clock inversion options
- External clock reference option
- Control signal forcing
- State-of-the-art digital CMOS technology
- Sturdy metal enclosure