Brocade Communications Systems RFS6000 is a high-performance Layer 3 switch that provides advanced features for enterprise networks. It offers wire-speed Layer 2 and Layer 3 switching, with support for up to 48 Gigabit Ethernet ports or 24 10 Gigabit Ethernet ports. The RFS6000 also provides advanced routing capabilities, including support for OSPF, BGP, and VRRP.
Some possible use cases for the Brocade Communications Systems RFS6000 include:
- Core switching: The RFS6000 can be used as a core switch in an enterprise network, providing high-performance connectivity between multiple subnets.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
42
® Brocade Mobility RFS4000 Controller Installation Guide Supporting software release 4.3.0.0 and later 53-1001933-02 Copyright © 2011 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, IronPoint, IronShield, IronView, IronWare, JetCore, NetIron, SecureIron, ServerIron, StorageX, and TurboIron are registered trademarks, and DCFM, Extraordinary Networks, and SAN Health are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify, products or services of their respective owners. Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government. The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it. Brocade Communications Systems, Incorporated Corporate and Latin American Headquarters Brocade Communications Systems, Inc. 130 Holger Way San Jose, CA 95134 Tel: 1-408-333-8000 Fax: 1-408-333-8101 E-mail: [email protected] Asia-Pacific Headquarters Brocade Communications Systems China HK, Ltd. No. 1 Guanghua Road Chao Yang District Units 2718 and 2818 Beijing 100020, China Tel: +8610 6588 8888 Fax: +8610 6588 9999 E-mail: [email protected] European Headquarters Brocade Communications Switzerland Sàrl Centre Swissair Tour B - 4ème étage 29, Route de l'Aéroport Case Postale 105 CH-1215 Genève 15 Switzerland Tel: +41 22 799 5640 Fax: +41 22 799 5641 E-mail: [email protected] Asia-Pacific Headquarters Brocade Communications Systems Co., Ltd. (Shenzhen WFOE) Citic Plaza No. 233 Tian He Road North Unit 1308 – 13th Floor Guangzhou, China Tel: +8620 3891 2000 Fax: +8620 3891 2111 E-mail: [email protected] Document History Title Publication number Summary of changes Date Brocade Mobility RFS4000 Controller 53-1001933-02 Installation Guide Updated WEEE icon April 2011 Brocade Mobility RFS4000 Controller 53-1001933-01 Installation Guide New Document July 2010 1 Introduction 1 Package contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Site preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2 Specifications 5 Physical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Power cord specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Power protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3 LED Codes 7 System status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Start up / POST (primary system or redundant system) . . . . . . . . . . . . . . . . . . . . . . . . . . . . Controller status (primary system) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Controller status (Redundant System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature status LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 8 9 9 9 RJ-45 Gigabit Ethernet LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 RJ-45 port speed LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 RJ-45 port activity LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 PoE status LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 SFP Gigabit Ethernet LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 SFP port speed LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 SFP port activity LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 4 Hardware Setup 13 Cabling Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Gigabit Ethernet on the Brocade Mobility RFS4000 Controller . . . . . . . . . . . . . . . .15 Installing Gigabit Ethernet SFPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Connecting USB devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Rack mount instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Brocade Mobility RFS4000 Controller console port setup . . . . . . . . . . . . . . . . . . . .20 Supplying power to the Brocade Mobility RFS4000 Controller . . . . . . . . . . . . . . . . .22 Using the Brocade Mobility RFS4000 Controller reset button . . . . . . . . . . . . . . . . .23 Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 iii Verifying the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 5 Regulatory Information 25 Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Country selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Laser devices - Gigabit Ethernet SFP option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Radio frequency interference requirements - FCC . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Radio frequency interference requirements - Canada . . . . . . . . . . . . . . . . . . . . . . . 27 CE Marking and European Economic Area (EEA) . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Statement of compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Japan (VCCI) - voluntary control council for interference Class B ITE . . . . . . . . . . . . . . . . . 28 Japan power cord statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Korea Warning Statement for Class B ITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Waste Electrical and Electronic Equipment (WEEE) . . . . . . . . . . . . . . . . . . . . . . . . . 29 iv Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 About This Document In this chapter • Audience • Supported hardware and software • Document conventions • Contacting Brocade • Warranty coverage v v vi vi vii Audience This document is designed for system administrators with a working knowledge of Layer 2 and Layer 3 switching and routing. If you are using a Brocade Layer 3 switch, you should be familiar with the following protocols if applicable to your network – IP, RIP, OSPF, BGP, ISIS, IGMP, PIM, DVMRP, and VRRP. Supported hardware and software The following hardware platforms are supported by this release of this guide: • Brocade Mobility RFS4000 Controller The following software version is supported by this release of this guide: • Software version 4.3.0.0 and later Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 v Document conventions This section describes text formatting conventions and important notice formats used in this document. Notes, cautions, and warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards. NOTE A note provides a tip, guidance or advice, emphasizes important information, or provides a reference to related information. CAUTION A Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware, firmware, software, or data. DANGER A Danger statement indicates conditions or situations that can be potentially lethal or extremely hazardous to you. Safety labels are also attached directly to products to warn of these conditions or situations. Contacting Brocade When contacting Brocade support, please provide the following information: • Serial number of the unit • Model number or product name • Software version vi Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 Customer Support Web Site Brocade Support Central Web site, located at www.brocade.com/support provides information and online assistance including developer tools, software downloads, product manuals and online repair requests. Downloads http://www.brocade.com/support/ Manuals http://www.brocade.com/support/ Because quality is our first concern at Brocade, we have made every effort to ensure the accuracy and completeness of this document. However, if you find an error or an omission, or you think that a topic needs further development, we want to hear from you. Forward your feedback to: [email protected]. Provide the title and version number and as much detail as possible about your comment, including the topic heading and page number and your suggestions for improvement. E-mail and telephone access Go to http://www.brocade.com/services-support/index.page for email and telephone contact information. Warranty coverage Contact Brocade Communications Systems using any of the methods listed above for information about the standard and extended warranties. Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 vii viii Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 Chapter 1 Introduction In this chapter • Package contents • Document conventions • Warnings • Site preparation 2 2 3 3 The Brocade Mobility RFS4000 Controller is a member of Brocade’s Mobility wireless controller family. The Brocade Mobility RFS4000 Controller provides centralized Wireless LAN (WLAN) configuration and management by coalescing a network “intelligence” previously spread across physically distributed access points. The Brocade Mobility RFS4000 Controller simplifies deployment of a Wired/Wireless 802.11 a/b/g/n network, for a SME/SMB. With the integrated Layer 2/Layer 3 Networking Services such as integrated Layer 2 Switching with PoE+ ports, Onboard DHCP Server, Security Services like Wired/Wireless Firewall, Wireless IDS/IPS, Onboard AAA Server and IPSEC VPN Gateway, and QoS mechanisms to support Voice & Video , the Brocade Mobility RFS4000 Controller transforms the enterprise by delivering a SMART Branch. The Brocade Mobility RFS4000 Controller is the WLAN’s point of management reducing wireless networking complexity by moving management out of the ceiling and into the wiring closet. The RFS4000 can adopt upto 6 Adaptive APs or Thin Access Points and does not require any additional licenses at this time, for AP adoption. This document is written for the network device installer. Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 1 1 Package contents Package contents Inspect the package contents and report any missing or damaged items to your sales representative. The package should contain the following: • • • • • Brocade Mobility RFS4000 Controller Console Cable Installation Guide (this document) Rubber Feet Power Supply Unit (Part Number: 50-14000-244R) Document conventions The following graphical alerts are used in this document to indicate notable situations: NOTE Tips, hints, or special requirements that you should take note of. CAUTION Care is required. Disregarding a caution can result in data loss or equipment malfunction. DANGER Indicates a condition or procedure that could result in personal injury or equipment damage. 2 Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 Warnings 1 Warnings • Read all installation instructions and site survey reports, and verify correct equipment installation before connecting the system to its power source. • Remove jewelry and watches before installing this equipment. • Install the equipment in a rack or on a desktop with adequate dimensions and weight allowances. • • • • • Verify the unit is grounded before connecting it to the power source. Verify any device connected to this unit is properly wired and grounded. Connect all power cords to a properly wired and grounded electrical circuit. Verify the electrical circuits have appropriate overload protection. Brocade strongly recommends the use of an Uninterruptible Power Supply (UPS) that supports the Brocade Mobility RFS4000 Controller power rating. Not using a UPS can result in data loss or equipment damage due to a power surge or power failure. • Verify that the power connector and socket are accessible at all times during the operation of the equipment. • Do not work with power circuits in dimly lit spaces. • Do not install this equipment or work with its power circuits during thunderstorms or other weather conditions that could cause a power surge. • Verify there is adequate ventilation around the device, and ambient temperatures meet equipment operation specifications. • This product is designed for in building installation only and is not intended to be connected to exposed (outside plant) networks. Site preparation • Consult your site survey and network analysis reports to determine specific equipment placement, port capacity, power drops, and so on. • • • • Assign installation responsibility to the appropriate personnel. Identify where all installed components are located. Verify appropriate rack mounting requirements, as required. Provide a sufficient number of power drops for your equipment. Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 3 1 Site preparation • Ensure adequate, dust-free ventilation to all installed equipment. • Identify and prepare Ethernet and console port connections. • Verify that cable lengths are within the maximum allowable distances for optimal signal transmission. • Verify that the Brocade Mobility RFS4000 Controller is powered through an Uninterruptible Power Supply (UPS). 4 Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 Chapter 2 Specifications In this chapter • Physical specifications • Power cord specifications 5 5 Physical specifications Width 304.8mm (12.0in) Height 44.45mm (1.75 in) 1 RU Depth 254mm (10.0 in) Weight 2.15 Kg (4.75 lbs) Operating Temperature 0°C - 40°C (32°F - 104°F) Operating Humidity 5% - 85% RH, non-condensing Operating Altitude 10,000 ft @ 28deg C < 15% Relative Humidity Power cord specifications A power supply is included, however a power cord is not supplied with the switch. Use only a correctly rated power cord certified (as appropriate) for the country of operation. Power protection • If possible, use a circuit dedicated to data processing equipment. Commercial electrical contractors are familiar with wiring for data processing equipment and can help with the load balancing of these circuits. Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 5 2 Power cord specifications • Install surge protection. Be sure to use a surge protection device between the electricity source and the Brocade Mobility RFS4000 Controller. • Install an Uninterruptible Power Supply (UPS). A UPS provides continuous power during a power outage. Some UPS devices have integral surge protection. UPS equipment requires periodic maintenance to ensure reliability. A UPS of the proper capacity for the data processing equipment must be purchased. 6 Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 Chapter 3 LED Codes In this chapter • System status LEDs • RJ-45 Gigabit Ethernet LEDs • SFP Gigabit Ethernet LEDs 7 10 11 The Brocade Mobility RFS4000 Controller has four vertically-stacked LEDs on its front panel. Each of the six Gigabit Ethernet Ports have two status LEDs. These LEDs display two colors (green & amber), and three lit states (solid, blinking, and off). The following tables decode the combinations of LED colors and states for the System Status LEDs and the Gigabit Ethernet LEDs. System status LEDs System Status 1 1 System Status 2 2 SYS Fan status Temperature status Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 7 3 System status LEDs Start up / POST (primary system or redundant system) System status 1 LED System status 2 LED Event off off power off green blinking green blinking power on self test (POST) running green solid green blinking post succeeded (operating system loading) green solid off post succeeded (normal operation) amber blinking off post failure alternating green blinking & amber blinking alternating green blinking & amber blinking system boot up error NOTE During controller start up, the Temperature status LED will be lit Solid Amber. This is normal behavior and does not indicate an error. At the completion of start up the Temperature Status LED will controller to Solid Green. Controller status (primary system) 8 System status 1 LED System status 2 LED Event off off power off green solid off redundancy feature enabled primary system normal operation no access ports adopted green solid green solid redundancy feature enabled primary system normal operation actively adopting access ports green solid amber blinking no country code configured on the controller or access port or adaptive ap license and country code configured, but no aps adopted Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 3 System status LEDs Controller status (Redundant System) System status 1 LED System status 2 LED Event off off power off green solid off redundant system normal operation green blinking green solid redundant system failed over and adopting ports green blinking alternating green blinking & amber blinking redundant system not failed over. Fan LED Fan LED Event off system off / POST start green blinking POST in process green solid all system fans normal operation amber solid redundant cooling failure system operational amber blinking system cooling failure - system will be held in reset until the issue is resolved Temperature status LED Temperature LED Event off system off green solid ambient inlet temperature is within specified operating limit amber solid ambient inlet temperature is near the maximum operating temperature. during controller start up this LED will be lit solid amber. this is normal behavior and does not indicate an error. amber blinking ambient inlet temperature is above the maximum specified operating temperature. system will be held in reset until the issue is resolved Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 9 3 RJ-45 Gigabit Ethernet LEDs RJ-45 Gigabit Ethernet LEDs LAN 1 3 2 4 5 PoE RJ-45 port speed LED Port speed LED Event off 10 Mbps green solid 100 Mbps green blinking 1000 Mbps amber blinking port fault RJ-45 port activity LED 10 Port status LED Event off no link or administratively shut down green solid link present Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 3 SFP Gigabit Ethernet LEDs Port status LED Event green blinking activity: transmit and receive amber blinking link fault PoE status LED Port status LED Event off PoE disabled or not in use green solid PoE enabled and powering port amber solid PoE over-limit amber blinking PoE port fault SFP Gigabit Ethernet LEDs UPLINK SFP Port speed Port activity Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 11 3 SFP Gigabit Ethernet LEDs SFP port speed LED Port speed LED Event green blinking 1000 Mbps amber blinking module or Tx/Rx fault loss SFP port activity LED 12 Port status LED Event off no link or administratively shut down green solid link present / operational amber blinking module or Tx/Rx fault loss Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 Chapter 4 Hardware Setup This chapter contains the following sections: • Cabling Information • Gigabit Ethernet on the Brocade Mobility RFS4000 Controller • Connecting USB devices • Rack mount instructions • Brocade Mobility RFS4000 Controller console port setup • Supplying power to the Brocade Mobility RFS4000 Controller • Using the Brocade Mobility RFS4000 Controller reset button • Verifying the installation 14 15 18 19 20 22 23 24 Console /$13R(HQDEOHGJLJDELWHWKHUQHW 83/,1. :$1 SRUWV Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 USB ([SUHVV&DUG6ORW 13 4 Cabling Information Cabling Information The Brocade Mobility RFS4000 Controller has five RJ-45 Gigabit Ethernet ports, one Gigabit SFP (fiber) port, one USB port, one Console connector and one ExpressCard slot. The above diagram shows each of those ports and the cables or devices attached to them. The sections that follow describe detailed connection and cabling information for each port. For software configuration, please see the Brocade Mobility RFS4000, RFS6000 and RFS7000 System Reference Guide available from the Brocade website at http://www.brocade.com/support/.. 14 Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 Gigabit Ethernet on the Brocade Mobility RFS4000 Controller 4 Gigabit Ethernet on the Brocade Mobility RFS4000 Controller The Brocade Mobility RFS4000 Controller has five RJ-45 Gigabit Ethernet ports and one 1 combo Gigabit (RJ45 + SFP) uplink port. Using the RJ-45 ports requires connecting a Category-6 Ethernet cable to the port. To use the Gigabit SFP port, first install the SFP Module. Installing Gigabit Ethernet SFPs 1. Open the bail on the transceiver. Open bail to insert or remove SFP transceiver Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 15 4 Gigabit Ethernet on the Brocade Mobility RFS4000 Controller 2. Insert the SFP transceiver into the corresponding port on the controller. 3. Once the SFP transceivers are properly seated in their ports, close the bails to lock the transceivers in place. Close bail to lock SFP transceiver in place 4. Insert the fiber optic cables into the installed transceivers. 16 Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 Gigabit Ethernet on the Brocade Mobility RFS4000 Controller Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 4 17 4 Connecting USB devices Connecting USB devices USB port The Brocade Mobility RFS4000 Controller contains one USB port for connecting USB flash storage devices to the controller. The controller can use the USB flash storage device for file transfers and firmware updates. Follow the setup instructions below to connect the devices to the controller and then access those devices through the Web UI or Command Line Interface. 1. Connect the USB flash drive to the USB . 2. Wait a few seconds for the drive to be recognized by the controller. 3. Follow the instructions in the Brocade Mobility RFS4000, RFS6000 and RFS7000 System Reference Guide or Brocade Mobility RFS4000, RFS6000 and RFS7000 CLI Reference Guide for more information on accessing USB storage devices from the controller for file transfers or firmware updates. These guides are available from the Brocade website at http://www.brocade.com/support/ 18 Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 4 Rack mount instructions NOTE The controller supports USB flash devices formatted with FAT or VFAT (FAT32) filesystems only. If your flash storage device is formatted with another filesystem you will need to format Rack mount instructions To install the Brocade Mobility RFS4000 Controller in a rack: 1. Attach the controller to the 1U rack mount kit (Part Number RFS-4010-MTKT1U-WR) using the guides provided. Switch Guides Power Supply Guide Cable Management Back Front Attach to Rack 1U Rack Mount Kit 2. Place the power supply unit in the rack mount tray in the space provided. Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 19 4 Brocade Mobility RFS4000 Controller console port setup 3. Attach the mounting tray to the rack using screws appropriate for your rack’s mounting holes. Brocade Mobility RFS4000 Controller console port setup To add the Brocade Mobility RFS4000 Controller to the network and prepare it for initial configuration: 1. Using the supplied console cable (pictured below), connect the Brocade Mobility RFS4000 Controller serial port to an RS-232 (DB-9) serial port on a separate computer (the “configuration computer”). The pinout for the RJ-45 to DB9 cable is shown in the following table. 20 RJ-45 1 2 3 4,5 6 7 8 DB9 8 6 2 5 3 4 7 Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 Brocade Mobility RFS4000 Controller console port setup 4 2. On the configuration computer, configure a terminal emulation application (such as HyperTerminal) as follows: 3. On the configuration computer, configure a terminal emulation application (such as HyperTerminal) as follows: Terminal type VT-100 Port COM port Terminal settings 19200bps transfer rate 8 data bits no parity 1 stop bit no flow control no hardware compression Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 21 4 Supplying power to the Brocade Mobility RFS4000 Controller Supplying power to the Brocade Mobility RFS4000 Controller Power Inlet 1. Plug the power supply (Part Number: 50-14000-244R) into the power inlet at the back of the Brocade Mobility RFS4000 Controller. 2. Plug the cord into a standard AC outlet with a voltage range of 100 to 240 VAC. CAUTION An improper shutdown can render the Brocade Mobility RFS4000 Controller inoperable such that it could require service by Brocade Support. Do not remove AC power without first following the shutdown procedure. An abrupt loss of power can corrupt the information stored on the device. 22 Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 4 Using the Brocade Mobility RFS4000 Controller reset button Using the Brocade Mobility RFS4000 Controller reset button Reset Button The Brocade Mobility RFS4000 Controller has a reset button on the rear of the switch near the power connector. To reset the switch to factory defaults: 1. Connect a computer to the Console Port as outlined in Brocade Mobility RFS4000 Controller console port setup on page 4-20 2. Reset the switch using the Web UI or the Command Line Interface. 3. As soon as the switch resets, depress the reset button on the rear of the switch and continue to hold it through the boot up process until the following message is displayed in the console: Startup config will be RESET to factory default loading linux image 2 ....................... Welcome to RFS4000 Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 23 4 Verifying the installation CAUTION Using the switch reset button will reset all configuration information and settings on the switch to factory defaults. All previously configured information and settings will be lost. The country code will need to be set when the switch is rebooted before any access ports or adaptive APs will be adopted. Verifying the installation View the LEDs on the front panel of the Brocade Mobility RFS4000 Controller to ensure the device is functioning properly. The normal LED pattern follows this path: • During the Power On Self Test (POST), the System 1 and System 2 LEDs both blink green. • If the POST test fails, the System 1 LED will blink amber. If the POST test succeeds, the System 1 LED will be lit solid green. • As the software is initialized, the System 2 LED will blink green. After the software has finished initializing, the System 1 LED will be lit solid green and the bottom System 2 LED will be off. The Brocade Mobility RFS4000 Controller is ready to be configured, as described in the Brocade Mobility RFS4000, RFS6000 and RFS7000 System Reference Guide available from the Brocade website at http://www.brocade.com/support/. Other LED codes indicate the presence (or absence) of different standby states, or errors. A guide to the Brocade Mobility RFS4000 Controller LED codes is provided in LED Codes on page 3-7. 24 Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 Chapter Regulatory Information 5 In this chapter • Country selection • Laser devices - Gigabit Ethernet SFP option • Radio frequency interference requirements - FCC • Radio frequency interference requirements - Canada • CE Marking and European Economic Area (EEA) • Waste Electrical and Electronic Equipment (WEEE) 26 26 26 27 27 29 This regulatory section applies to the Brocade Mobility RFS4000 Controller. All Brocade devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Any changes or modifications to Brocade equipment, not expressly approved by Brocade, could void the user’s authority to operate the equipment. CAUTION This product is designed and approved for in-building installation only and is not intended to be connected to exposed (outside plant) networks. Power supply Use only a Brocade approved power supply output rated at 48Vdc and minimum 2.5A. The power supply shall be Listed to UL/CSA 60950-1; and certified to IEC60950-1 and EN60950-1 with SELV outputs. Use of alternative power supply will invalidate any approval given to this device and may be dangerous. Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 25 5 Country selection Country selection Select only the country in which you are using the device. Any other selection will make the operation of this device illegal. ! Laser devices - Gigabit Ethernet SFP option Complies with 21CFR1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001. EN60825-1:1994+ A1:2002 +A2:2001 IEC60825-1:1993+A1:1997+A2:2001 The laser classification is marked on the device. Class 1 Laser devices are not considered to be hazardous when used for their intended purpose. The following statement is required to comply with US and international regulations: CAUTION Use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Radio frequency interference requirements - FCC This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular 26 Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 Radio frequency interference requirements - Canada 5 installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help. Radio frequency interference requirements - Canada This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. CE Marking and European Economic Area (EEA) Statement of compliance Brocade hereby declares that this device is in compliance with all the applicable Directives, 2004/108/EC, 2006/95/EC. A Declaration of Conformity may be obtained from http://www.2symbol.com/doc/ Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 27 5 CE Marking and European Economic Area (EEA) Japan (VCCI) - voluntary control council for interference Class B ITE この装置は、情報処理装置等電波障害自主規制協議会 (VCCI)の基準に基 づくクラス B 情報技術装置です。この装置は、家庭環境で使用することを目的 としていますが、この装置がラジオやテレビジョン受信機に近接して使用され ると、受信障害を引き起こすことがあります。取扱説明書に従って正しい取り 扱いをして下さい。 This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. Japan power cord statement Korea Warning Statement for Class B ITE 기종별 B 급 기기 ( 가정용 방송통신기기 ) Class B (Broadcasting Communication Device for Home Use) 사용자안내문 이 기기는 가정용 (B 급 ) 으로 전자파적합등록을 한 기기로서 주로 가정에서 사용하는 것을 목적 으로 하며 , 모든 지역에서 사용할 수 있습니다 . This device obtained EMC registration mainly for home use (Class B) and may be used in all areas. Turkish WEEE Statement of Compliance EEE Yönetmeli?ine Uygundur 28 Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 Waste Electrical and Electronic Equipment (WEEE) 5 Waste Electrical and Electronic Equipment (WEEE) For information on WEEE, please go to: http://www.brocade.com/sites/dotcom/company/ corporate-responsibility/corporate-citizenship/product-recycling/ weee.page. Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02 29 5 30 Waste Electrical and Electronic Equipment (WEEE) Brocade Mobility RFS4000 Controller Installation Guide 53-1001933-02
advertisement
Key Features
- Centralized WLAN management
- Simplified Wired/Wireless 802.11 a/b/g/n network deployment
- Integrated Layer 2/Layer 3 Networking Services
- Onboard DHCP Server
- Security Services (Wired/Wireless Firewall, Wireless IDS/IPS, Onboard AAA Server and IPSEC VPN Gateway)
- QoS mechanisms for Voice & Video
- Support for up to 6 Adaptive APs or Thin Access Points
Frequently Answers and Questions
What are the physical dimensions of the Brocade RFS6000?
The Brocade RFS6000 has a height of 1.75 inches (4.45 cm), a width of 17.5 inches (44.45 cm), and a depth of 11.19 inches (28.42 cm).
How much does the Brocade RFS6000 weigh?
The Brocade RFS6000 weighs 14.6 pounds (6.6 kg).
What are the power requirements for the Brocade RFS6000?
The Brocade RFS6000 requires dual AC 100-240V @ 50/60Hz, 10A max input power.
What is the maximum power consumption of the Brocade RFS6000?
The maximum power consumption of the Brocade RFS6000 is 350 Watts with PoE+, and 140 Watts without PoE+.
What is the operating temperature range of the Brocade RFS6000?
The Brocade RFS6000 has an operating temperature range of 32 to 104 degrees Fahrenheit (0 to 40 degrees Celsius).
What is the storage temperature range of the Brocade RFS6000?
The Brocade RFS6000 has a storage temperature range of -40 to 158 degrees Fahrenheit (-40 to 70 degrees Celsius).
What is the relative humidity range for the Brocade RFS6000?
The Brocade RFS6000 has a relative humidity range of 10% to 90% (non-condensing).
What is the altitude range for the Brocade RFS6000?
The Brocade RFS6000 has an altitude range of up to 10,000 feet (3,048 meters).