Catalogue Sheet: RHC Series

Catalogue Sheet: RHC Series
Type:
new product
Project/Location:
Contractor:
Prepared By:
Date:
Model No.:
Made in Canada
TYPICAL SPECIFICATIONS
RHC SERIES
Pictogram Combo, Hazardous
Locations: Class I Div 2,
Class II Div 1&2 and Class III
FEATURES
•Includes the addition of Class II Div 1&2
Groups E, F and G as well as Class III
ratings
• Certified Class I Div 2, Groups A, B, C
and D as per CSA C22.2 No.137-M1981
• Certified temperature Codes for several
types of emergency lamps
• Certified CSA C22.2 No.141-10
• Polyvinyl chloride frame, with built-in
gasket to prevent water infiltration
• Heavy-duty 1/8” thick aluminum back
plate with keyholes for wall-mount
installation
• Sealed, polycarbonate vandal-resistant
faceplate
• Legend illuminated by long-life white
LEDs
• Comes standard with two pictogram
films for direction selection
• Two high-performance MR16 LED
lamps shielded by a clear polycarbonate
cover
• 5W LED emergency lights provide
60 ft of egress illumination on a 6-foot
wide path
• 6 W LED emergency lights provide
100 ft of egress illumination on a 6-foot
wide path
• Sealed, maintenance-free Lead-Calcium
or Nickel-Cadmium batteries
• Remote load capacity: covers with LED
lights 200 ft up to 500 ft of egress
illumination
• Comes standard with auto-diagnostic
• Cold-weather option: -40°C with only
14W extra power consumption
Supply and install Ready-Lite® RHC Series combination emergency light battery unit and pictogram sign.
Designed specifically for hazardous locations, the equipment frame shall be of industrial grade polyvinyl
chloride with gaskets around both sides of the frame contour. The back plate shall be made of 1/8” thick
aluminum sheet and shall include knock-outs for installation on an electrical box and four keyholes for alternative installation on a wall surface. The faceplate shall be constructed of heavy-duty vandal-resistant clear
polycarbonate and feature a uniformly illuminated pictogram legend.
The unit shall come standard with two legend films for pictogram and direction selection. The light source shall
be long-life white light-emitting diodes (LED). The unit shall have attached a lower compartment containing
two emergency heads with adjustable swivels and long-life MR-16 LED lamps of ___ V and ___ W. The heads
shall be installed on a shield housing made of cast aluminum and protected by a shock-absorbent, clear
polycarbonate cover. The standard AC input voltage shall be 120/347VAC. The equipment shall be equipped
with a magnetic test switch and one LED pilot light protected by the face plate.
The unit shall perform auto-test functions managed by a micro-controller and shall automatically self-test for
one minute every 30 days, 10 minutes in the 6th month and 30 minutes annually. When a fault is detected,
the bi-color pilot light shall turn from green to red and flash following a particular code. The code description
shall be displayed on a label next to the pilot light to identify the failure type: battery, charger circuitry, LED
lights for the signage, or emergency lights. The combination unit shall be approved CSA C22.2 No.141-10
and No.137-M1981 for Class I Division 2 Groups A, B, C and D, Class II Divison 1&2 Groups E, F and G as
well as Class III.
The combination unit shall be Ready-Lite® model:
.
H A Z A R D O U S L O C AT I O N FA M I LY C L A S S I , I I A N D I I I
RH P. 68
TUFHZ P. 69
HZ Combo P. 72-73
LDX-HZ Battery P. 130-131
NMHZ Remote P. 164
TEMPERATURE CODES (CLASS I DIVISION 2)
LAMP RATING
TEMPERATURE CODE
MAX. TEMPERATURE
REPLACEMENT LAMP
6V-10W
T3C
160°C
580.0079-RL
12V-12W
T3A
180°C
580.0080-RL
12V-20WH
T2D
215°C
580.0068-RL
6V-4W LED
T4A
120°C
580.0097-RL
12V-4W LED
T4A
120°C
580.0093-RL
12V-5W LED
T4A
120°C
580.0104-RL
12V-6W LED
T4
135°C
580.0106-RL
POWER CONSUMPTION
MODEL
AC SPECS
EMERGENCY POWER AVAILABLE FOR LAMPS
30MIN
1H00
1H30
2H00
4H00
Pictogram Sign Module
less than 2.5W
-
-
-
-
-
RHC-6L36
0.10/0.03 A
36
21
15
12
-
RHC-6L36-CW
0.25/0.08 A
36
21
15
12
-
0.10/0.03 A
36
30
20
16
8
RHC-6N36-CW
0.25/0.08 A
36
30
20
16
8
RHC-12N60
0.18/0.06 A
60
40
30
20
10
RHC-6N36
120/347VAC
70
Type:
new product
Project/Location:
Contractor:
Prepared By:
Date:
Model No.:
DIMENSIONS
Dimensions are approximate and subject to change.
RHC SERIES
14-1/2” [36.8 cm]
3-1/2” [8.7 cm]
13-3/4” [34.9 cm]
Pictogram Combo, Hazardous
Locations: Class I Div 2,
Class II Div 1&2 and Class III
PICTO
STRAIGHT FROM HERE
6-1/4” [15.9 cm]
12-5/8” [32.1 cm]
<PICTO
LEFT FROM HERE
PICTO>
RIGHT FROM HERE
ORDERING INFORMATION
SERIES
RHC= pictogram combo
HOUSING COLOUR
BATTERY TYPE AND POWER
G= grey
6L36= 6V-36W, lead-calcium
6N36= 6V-36W, NiCad
12N60= 12V-60W, NiCad
HEAD STYLE AND WATTAGE
Blank= no heads*
LD1= MR16 LED, 6V-4W
LD7= MR16 LED, 12V-4W
LD9= MR16 LED, 12V-5W
LD10= MR16 LED, 12V-6W
MK= MR16 halogen, 12V-12W
MW= MR16-IR, 12V-20W, high output
*Remote load must be connected.
EXAMPLE: RHCG12N60LD7
71
OPTIONS
Blank= auto-diagnostics, non-audible (standard)
U2= 120/277VAC input
AD= auto-diagnostics, audible
NEX= NEXUS® system interface*
NEXRF= wireless NEXUS® system interface*
CW= cold-weather -40°C (only 6V units)
D1= time delay (5 mins.)
D2= time delay (10 mins.)
D3= time delay (15 mins.)
*Not all options available with NEXUS® System. Please
consult your sales representative
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF