EAST COAST DATACOM, INC., DBU-HSSI INSTALLATION AND OPERATIONS MANUAL
TABLE OF CONTENTS
CHAPTER 1 - DESCRIPTION
. . . . . . . . . . .
1
CHAPTER 2 - BASIC OPERATION
. . . . . . . . . . .
2
DB-25, HSSI PORT PIN OUTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
FRONT PANEL LED INDICATOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
CHAPTER 3 - SETUP AND INSTALLATION
. . . . . . . . . . .
3
POWER CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
CABLING REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
EQUIPMENT GROUNDING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
OPERATIONS MANUAL
DATA BROADCAST UNIT
DBU-HSSI
December 18, 2002
FOR TECHNICAL SUPPORT CALL:
East Coast Datacom, Inc.
245 Gus Hipp Blvd., STE 3
Rockledge, FL 32955
TEL: (800) 240-7948 or (321) 637-9922
FAX: (321) 637-9980
Web Site: www.ecdata.com
Manufactured By
:
East Coast Datacom, Inc.
PT # 153010-A
EAST COAST DATACOM, INC., DBU-HSSI INSTALLATION AND OPERATIONS MANUAL
SAFETY WARNING
Always observe standard safety precautions during installation, operation and maintenance of this product. To avoid the possibility of electrical shock, be sure to disconnect the power cord from the power source before you remove the IEC power fuses or perform any repairs.
PROPRIETARY NOTICE
The information contained herein is proprietary to East Coast Datacom, Inc. Any reproduction or redistribution of this publication, in whole or in part, is expressly prohibited unless written authorization is provided by East Coast Datacom, Inc.
WARRANTY NOTICE
WARRANTIES: East Coast Datacom, Inc. (hereafter referred to as E.C.D.) warrants that its equipment is free from any defects in materials and workmanship. The warranty period shall be three (3) years from the date of shipment. E.C.D.'s sole obligation under its warranty is limited to the repair or replacement of defective equipment, provided it is returned to E.C.D., transportation prepaid, within a reasonable period. This warranty will not extend to equipment subjected to accident, misuse, alterations or repair not made by E.C.D. or authorized by E.C.D. in writing.
PUBLICATION NOTICE
This manual has been compiled and checked for accuracy. The information in this manual does not constitute a warranty of performance. E.C.D. reserves the right to revise this publication and make changes from time to time in the content thereof.
E.C.D. assumes no liability for losses incurred as a result of out-of-date or incorrect information contained in this manual.
i
EAST COAST DATACOM, INC., DBU-HSSI INSTALLATION AND OPERATIONS MANUAL
EMISSIONS REQUIREMENTS
FCC CLASS A
NOTE
: This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
WARNING
: Charges of modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
CANADIAN EMISSIONS
This digital apparatus does not exceed the Class A limits for noise emissions from a digital apparatus set out in the Radio Interference Regulations of the Canadian
Department of Communications.
Le present appareil numerique n'emet pas de bruits redioelectriqes depassant les limites applicables aux appareils numeriques de la Class A prescites dans le Reglement sur le brouillage redioelectrique edicte par le ministere des Communications du Canada.
EAST COAST DATACOM, INC., DBU-HSSI INSTALLATION AND OPERATIONS MANUAL
CHAPTER 1 - DESCRIPTION
The DBU-HSSI is designed for use in receive only data broadcast applications.
Examples of typical data broadcast applications are; continuously updated private or public data displays and distribution of continuous data to PC's or Routers. The expanding role of VSAT systems in receive only applications for real time data distribution is expected to increase dramatically over the next few years. The
DBU-HSSI is an excellent choice for applications of this type.
The DBU-HSSI utilizes an ECL balanced interface with a maximum data rate of up to
52Mbps. Additionally, the unit has HSSI compliant voltage levels pinned to standard female EIA DB-25 connectors.
The DBU-HSSI continuously broadcasts receive data and receive timing. The
DBU-HSSI's master port should be connected to the HSSI transmitter(DCE device).
The input signals are split with the internal circuitry and rebroadcast out on the four output ports. All output ports should be connected to DTE devices.
The DBU-HSSI is housed in a sturdy aluminum enclosure and is supplied with an internal linear power supply. The unit has a 110/220 VAC rotary select switch located on the rear of the housing. The unit can operate on standard AC power found in all countries.
HOST
ONE WAY DATA PATH TO TERMINALS
MODEM
LEASED LINE
MODEM
EAST COAST
D A T A C O M , I N C.
DBU-V11
TERMINAL
ECL BALANCED
INTERFACE
DBU-HSSI
TYPICAL APPLICATION
1-1
Page 1
EAST COAST DATACOM, INC., DBU-HSSI INSTALLATION AND OPERATIONS MANUAL
CHAPTER 2 - BASIC OPERATION
Operation of the DBU-HSSI is as simple as plugging a male DB-25 cable into the female DB-25 MASTER port on the back panel and plugging up to four male DB-25 connectors into Ports 1 - 4. Data and Clock are received on the Master Port and are broadcast out simultaneously on ports 1 - 4. The following table shows the pin-out for the Master and sub-channel ports.
DB-25, HSSI(ECL) PORT PIN OUTS
ALL DB-25 FEMALE CONNECTORS
PIN NUMBER
13
PIN NAME
SHIELD/GND
10
23
5
18
DATA +
DATA -
CLOCK +
CLOCK -
FRONT PANEL LED INDICATOR
Located on the front of the DBU-HSSI is a green LED. The Power indicator, marked
POWER illuminates when AC voltage is applied to the box.
Page 2
EAST COAST DATACOM, INC., DBU-HSSI INSTALLATION AND OPERATIONS MANUAL
CHAPTER 3 - SETUP AND INSTALLATION
POWER CONNECTION
It is very important to check that the unit is set to the correct voltage setting for your application before applying AC power. Located on the rear of the unit you will find a rotary 110/220 VAC switch. Using a coin or small screwdriver, gently turn the switch to the appropriate power position as required for your installation (110 or 220 VAC).
INSTALLATION
Connect the main input data feed source into the MASTER port DB-25 female connector. The output ports are marked PORT 1 through PORT 4. Connect from one to four DTE HSSI (ECL) compliant devices into the sub-channels ports on the back of the unit.
CABLING REQUIREMENTS
High quality shielded cables are recommended. It is very important to use the correct cable types. The following is recommended (or equivalent).
Cable type: multi-conductor cable, consisting of 25 twisted pairs cabled together with an overall double shield and PVC jacket
Gauge: 28 AWG, 7 strands of 36 AWG, tinned annealed copper, nominal 0.015 in.
diameter
Insulation: polyethylene or polypropylene; 0.24 mm, .0095 in. nominal wall thickness;
0.86 mm +/- 0.025 mm, .034 in. +/- 0.001 in. outside diameter
Foil Shield: 0.051 mm, 0.002 in. nominal aluminum/polyester/aluminum laminated tape spiral wrapped around the cable core with a 25% minimum overlap
Braid Shield: braided 36 AWG, tinned plated copper in accordance with 80% minimum coverage jacket: 75 degrees C flexible polyvinylchloride
Jacket Wall: 0.51 mm, 0.020 in. minimum thickness
Dielectic Strength: 1000 VAC for 1 minute
Outside Diameter: 10.41 mm +/- 0.18 mm, 0.405 in. +/- 0.015 in.
Agency Complience: CL2, UL Subject 13, NEC 725-51(c) + 53(e)
Manufacturer P/N: QUINTEC (Madison Cable 4084) ICONTEC RTF-40-25P-2 (Berktek, C&M)
Page 3
EAST COAST DATACOM, INC., DBU-HSSI INSTALLATION AND OPERATIONS MANUAL
EQUIPMENT GROUNDING
A Jumper provides for grounding interconnection in those systems requiring a connection between frame ground and signal ground. Remove the DBU-HSSI rackmount cover to locate the jumpers on the printed circuit card. Move the jumper to the front two header positions to connect the grounds, if your system requires such a connection. The factory default is NO CONNECT, the back two header positions.
Page 4
EAST COAST DATACOM, INC., DBU-HSSI INSTALLATION AND OPERATIONS MANUAL
TECHNICAL SPECIFICATIONS
Front Panel
Indicator: Power
Applications
Multiple synchronous broadcasting of
Data and Clock
Capacity
One to four sub-channels; standard
DB-25 pin (female) interface connector for each sub-channel
Data Format
Data transparent at all data rates
Data Rates
Up to 52Mbps
Electrical Interface
HSSI compliant(ECL levels)
Sub-Channel Interfaces
HSSI, DB-25 female connector
Master Port
HSSI, Female DB-25 connectors
Power Requirement
100-120/200-220 VAC @+10%, 47 to 63 Hz, 7 Watts
Switch selectable
ENVIRONMENTAL
Operating Temperature: 32
0
to
122 F (0
0
to 50
0
C)
Relative Humidity: 5 to 90% noncondensing
Altitude: 0 to 10,000 feet
Dimensions
Height: 1.75 inches (4.44 cm)
Width:
Length:
17.00 inches (43.18 cm)
9.00 inches (22.86 cm)
Weight
4.5 lbs (2.1 Kg)
Enclosure
Metal: Aluminum
Altitude
9842 feet (3000 meters)
Shock and Vibration
Withstands normal shipping
Page 5