Culligan Platinum, Gold water softener Programming instructions

Culligan Platinum, Gold water softener Programming instructions

Below you will find brief information for water softener Platinum, water softener Gold. This is an easy-to-follow guide on how to program your Culligan water softener. The programming instructions cover important settings such as regeneration time, salt type and water hardness. You can customize the settings based on your specific needs and preferences, ensuring optimal performance and efficiency of your water softener.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Culligan Platinum and Gold Water Softener Programming Instructions | Manualzz
Cat No. 01017424
Rev. A 1/8/04
DCO 6728
Culligan Platinum Series and Culligan Gold Series Standard Programming Instructions
Use this sheet to assist in programming the Culligan Platinum Series and Gold Series water softeners. Please refer to the Culligan Platinum
Series and Culligan Gold Series Installation and Operation Manual if modifications need to be made to the programming options.
Make sure the inlet water supply is turned off, then connect power to the unit. The display will power-up flashing “12:00 PM”. The motor will
energize and cycle the control without stopping to the home position.
Hours Flashing
DIP Switches
The controller uses DIP switches as a means of programming
Press the “Regen” key to flash
specific options. Options to be programmed are as follows listed
hours. Adjust the hours with the ▲
H24 Dips
in the Off / On position:
or ▼ key.
•
•
•
•
•
•
•
•
•
•
Run/Test
DIP #1 – Run / Test
Soft/Fil
DIP #2 – Softener / Filter
Control Select
DIP #3 – Control Selection
Control Select
DIP #4 - Control Selection
Slow/Fast
DIP #5 – Slow / Fast Refill
Delay/Immed
DIP # 6 – Delayed / Immediate
Eng/Met
DIP #7 – English / Metric
12hr/24hr
DIP #8 – 12 HR / 24 HR
Advanced
DIP #9 – Advanced Off / On
DIP #10 – Time Clock Backup Off / On TCB
Press the “Status key to save the
setting and move to the next
programming step.
•
After “tor”, the display will show
“2:00 AM” (or the current time of
regeneration if already
programmed). The time is adjusted
in 30 minute increments with the ▲
or ▼ key.
Press the “Status key to save the setting and move to the
next programming step.
DIP Switch 3 & 4 are used to select the control type as shown
below:
GOLD PLAT EURO OTHR
OFF
ON
DIP Switch 5 is set to the OFF position for 9” & 10” tanks (0.45
gpm brine refill flow control) and to the ON position for 12”, 14” &
16” tanks (0.80 gpm brine refill flow control).
Display Icons
The display is backlit and has the icons as shown below:
Programming
•
Beeper Setting – This setting is
used to turn the beeper on or off
for each key press actuation.
The display will show “bEEP X”
where X is either “Y” or “N” The “Y” or “N” are toggled with
the ▲ and ▼keys. Setting the beep option to “N” will only
disable the beeper for key press actuation. It is still active for
error and alarm codes.
•
Time of Day – This setting
programs the current time of day.
The display will first show “tod” for
two seconds.
After “tod” is displayed, “12:00 PM”
will display (or the current set time
if already programmed) and the
minutes will flash. Adjust the
minutes with the ▲ or ▼ key.
•
Iron Setting (Flow Meter Only) –
This setting is used to set the iron
level (PPM) of the influent water
supply. “IRON” is displayed in the
left most digits and the iron default
setting (or previously programmed value) in the far right digit.
Adjust the value with the ▲ or ▼ key.
Press the “Status” key to move to the next programming step.
The value will not be saved until the “Status” key is pressed
after the Defaults programming step.
•
Minutes Flashing
Hardness Setting (Flow Meter
Only)– This setting is used to input
the hardness (grains) of the influent
water supply. The display will show
“HArd” for two seconds and then
display the hardness default (or
previously programmed value).
Adjust the value with the ▲ or ▼
key.
Press the “Status” key to move to the next programming step.
The value will not be saved until the “Status” key is pressed
after the Defaults programming step.
Press the “Status key to save the setting and move to the
next programming step.
•
Time of Regeneration – This
setting is used to program the time
at which a regeneration occurs in
the delay mode or when time clock
backup is enabled in immediate
mode. The display will show “tor” for two seconds.
Salt Type (Flow Meter Only) –
This setting is used to select the
regeneration salt type – Sodium
Chloride (NaCl) or Potassium
Chloride (KCl). The display will
show “SALt” for two seconds and
then “NACL” (or previously
programmed value), Toggle between “NACL” and “KCL” with
the ▲ or ▼ key.
Press the “Status” key to move to the next programming step.
The value will not be saved until the “Status” key is pressed
after the Defaults programming step.
•
Gold or Platinum Tank Size
(Flow Meter Only) – This setting
is used to input the size tank that
the control is connected to. The
display will show “GOLd” (or
“PLAtIN”) for two seconds and
then display the tank size default
(or previously programmed value).
Adjust the tank size with the ▲ or
▼ key.
Press the “Status” key to move to the next programming step.
The value will not be saved until the “Status” key is pressed
after the Defaults programming step.
•
•
•
•
Efficiency Mode (Flow Meter
Only) – Efficiency mode will only
be available if the hardness is 20
gpg or less and iron is 0 PPM
(Mode is not available if DIP switch
#6 or #9 are on). The “EFFICIENCY MODE” icon will display
with a default of “NO”. Toggle between “NO” and “YES” with
the ▲ or ▼ key.
Press the “Status” key to move to the next programming step.
The value will not be saved until the “Status” key is pressed
after the Defaults programming step.
•
Press the “Status key to save the
setting and move to the next
programming step.
Defaults (Flow Meter Only) –
This setting allows the control to
automatically set the values of salt
dosage, cycle times, batch
capacity and total capacity based
on the above inputted values. The
display will show “dEFLtS” for two
seconds and then display “YES”.
Toggle between “YES” and “NO”
with the ▲ or ▼ key.
If “YES” is selected, then pressing the “Status” key will save
the automatically set values and move to the next
programming step.
If “NO” is chosen, then the options for cycle times, salt
dosage, batch capacity and total capacity will be available
with successive presses of the “Status” key.
View (Flow Meter Only, Defaults Yes) – This setting allows
the programmer to view the calculated and looked up values
for salt dosage, cycle times, batch
capacity and total capacity. The
values can only be viewed and not
changed. The display shows
“View N”. Toggle between “N”
and “Y” with the ▲ or ▼ key. If “Y” is selected, successive
presses of the “Status” key will cycle through the values. If
“N” is selected, pressing “Status” will exit programming mode
and return to the time display.
Salt Dosage (Aqua-Sensor) – This setting is used to set the
salt dosage. The display shows
“doSAGE” for two seconds and
then “LbS XX” where XX is the
salt dosage in pounds. Adjust the
dosage with the ▲ or ▼ key.
Backwash (Aqua-Sensor) – This setting is used to set the
backwash time in minutes. The
display shows the “BACKWASH”
and “MINS” icons along with XX in
the rightmost digits where XX
represents the time in minutes for
backwash. Adjust the minutes with the ▲ or ▼ key.
Press the “Status” key to save the setting and move to the
next programming step.
•
Brine Rinse (Aqua-Sensor) – This
setting is used to set the brine rinse
time. The display shows the
“BRINE RINSE” and “MINS” icons
along with 99 (or previously
programmed value) in the rightmost digits where 99
represents the time in minutes for brine rinse. Leaving the
value at the 99 minute default enables the brine rinse out
alarm function. Adjust the minutes with the ▲ or ▼ key.
Press the “Status” key to save the setting and exit
programming mode to return to the time display.
Manual Control Cycling
The control can be manually cycled through a regeneration to
troubleshoot the control or verify that the set-up is complete. A
manual cycling of the control is accomplished by following the
steps as outlined below:
1.
While in the service mode, press the “Statistics” key.
2.
Press the ▲ key to display the current motor position. If
a flow meter is attached the
display will have a “F” in the
leftmost position, an AquaSensor will show “A” in the next
position. If in the service
(Home) position the rightmost digits will alternate
between “HM” and “00 MINS”.
3.
Press and hold the “Regen” key for 5 seconds until the
regeneration is started. Once regeneration is active, the
“Regen” key will be ignored until the control returns to the
service or “home” position.
4.
The “REGEN” icon will flash
and the control will cycle to the
Backwash position. When in
the Backwash position the
display will continue to flash the
“REGEN” icon and in addition
display the “BACKWASH” and “MINS” icons and the time
remaining for the cycle in the rightmost digits (“F” or “A”
will also show as in 2 above if applicable).
5.
Press the ▲ key to cycle to the next position and remain
there until the cycle times out or the control is manually
indexed.
6.
Repeat step 5 until the control returns to the service
(Home) position. In order to step through the cycles
again, repeat at step 3.

advertisement

Key Features

  • Programmable settings
  • Time clock backup
  • Efficiency mode
  • Salt type selection
  • Tank size input
  • Automatic defaults
  • Manual control cycling
  • Clear display icons

Frequently Answers and Questions

How can I program the regeneration time?
To program the regeneration time, press the "Regen" key to flash the hours and adjust the time using the up and down arrows. Save the setting by pressing the "Status" key.
What options are available for salt type selection?
You can select between Sodium Chloride (NaCl) or Potassium Chloride (KCl) by navigating to the "Salt Type" setting and toggling between the options using the up and down arrows.
How do I manually cycle through a regeneration?
Enter service mode, press "Statistics" key, press and hold "Regen" key for 5 seconds to start regeneration, use the up arrow key to cycle through each position in the regeneration sequence, repeat steps if needed.
How often should I check and adjust the settings?
You can manually check the settings and adjust them based on your needs and the quality of your water. It's generally advisable to review at least once every few months or as needed, particularly when water hardness or usage patterns change.